Boost Pumps Features & Benefits ■ Compact design is lightweight and reduces installation time ■ Hydraulic drive allows operators to use truck PTO system ■ Bearing housing designed for well service, heavy duty applications Right Hand Discharge 2x3x6 2 3 6 & 2x4x6 2 6 ■ Composite Face Seal (CFS) more tolerant of cavitation Pump Performance Curve Left Hand Discharge 1x2x4.5 & 1.5x2.5x6A 1x2x Pressure Testing *(Maximum Capacity) In some instances where hydrostatic testing may not be possible, systems or components may be tested with nitrogen. If considering this as an alternative, it is mandatory that the system design specifications be reviewed and a risk analysis be conducted before using a compressible medium for the test. Pipe Freezing Flow Range: 5-500 GPM / 20-1,900 lpm NPSHR: 3-35 Feet / 1-10 Meters Differential Head: 40-780 Feet / 13-240 Meters Pump Design Rating*: 1-85 hp / 0.75-60 kw RPM Range: 1 x 2 x 4.5 2,000-10,200 RPM 1.5 x 2.5 x 6A 2,000-7,200 RPM 2x3x6 2,000-8,100 RPM 2x4x6 2,000-8,100 RPM The boiling point of liquid nitrogen is -320°F (-195°C) and as such it has an application as a coolant in indirect pipe freezing systems. Users of ACD’s cryogenic pumps have reported that on pipe-work compatible with cryogenic liquids, liquid nitrogen can be used as the direct cooling medium. The benefits of this approach over conventional methods reportedly are: s More effective use of plant/platform personnel s No interruptions to the process system while repairs are carried out s There is “no draining operation” thus, saving time s Liquid waste is limited resulting in cost savings s Isolation for pressure or leak testing is provided Enhanced Oil Recovery 7 Model AC-18 (HD) Boost Pump/Trailer off load Performance range gpm 5-500 lpm 20-1,900 feet 3-35 meter 2-10 Flow Range NPSHR Right Hand Discharge 2x3x6&2x4x6 Differential Head Pump Design Rating RPM Range feet 40-780 meter 13-240 hp 1-85 kw 0.75-60 1 x 2 x 4.5 1.5 x 2.5 x 6A 2x3x6 2x4x6 2,000-10,200 2,000-7,200 2,000-8,100 2,000-8,100 rpm Left Hand Discharge 1 x 2 x 4.5 & 1.5 x 2.5 x 6A Features & Benefits Applications Optional Accessories •Compact design is lightweight and reduces installation time •Well service •Purge kit (bearings) •Transfer boost pump •Mating flanges •Hydraulic drive allows operators to use truck pto system •Trailer off load •Bearing housing designed for well service, heavy duty applications •Shaft seal features CFS design, extending seal life Liquids Pumped Typical Scope of Supply •Nitrogen •Pump, bearing housing and hydraulic coupling •Methane •Argon •CFS mechanical seal •Purge ports Manufacturing Model AC-18 (HD) overall Dimensions: Typical 2 x 3 x 6 hd 23.3+- .3 [592+-8] 2. 4.25 [108] Hydraulic Motor 17.8 hp at 2500 psi working pressure and 4700 RPM Discharge Flange: Mates with STD 2" 150# ANSI Flat Face Flange Discharge Flange: may be rotated in increments of 45 o 6.00 [154] 4.20 [107] 5.10 [130] 1.75 [45] .60 [15] 2. 6.00 [154] 1.2 [30] 1.2 [30] .62 [16] 8.5+- .2 [216+-5] 4.25 [108] 4.25 9.7 [108] [246] Suction Flange: Mates with STD 3" 150# ANSI Flat Face Flange Hydraulic Motor may be rotated ino increments of 90 Gutenbergstrasse 1 CH-4142 Muenchenstein Switzerland Tel: +41.61.413.0230 Fax: +41.61.413.0233 sales@acdcryo.com • acdcryo.com Global service 10.4 [264] Drain: .562-18 UNF-2B SAE Thread Plugged 2321 S. Pullman Street Santa Ana, CA 92705 USA Tel 800.525.4216 (USA only) Tel +1.949.261.7533 Fax +1.949.261.6285 acd@acdllc.com • acdllc.com .44Δ [11] Thru 4 Holes inch/[mm] North America Atlanta Atlanta, Georgia, USA +1 404.696.8113 • Fax +1 404.696.8116 sales@cryoatlanta.com • cryoindservice.com California Santa Ana, California, USA +1 949.724.8636 • Fax +1 714.641.1921 sales@cryocal.com • cryoindservice.com Houston Houston, Texas, USA +1 281.590.4800 • Fax +1 281.590.4801 sales@cihouston.com • cryoindservice.com Pittsburgh Imperial, Pennsylvania, USA +1 724.695.1910 • Fax +1 724.695.1926 pittcryo@pittcryogenic.com • cryoindservice.com Red Deer Red Deer, Alberta, Canada +1.403.352.4436 • Fax +1.403.352.4439 sales@cryocanada.com • cryoindservice.com Pump Performance curve Toronto Toronto, Ontario, Canada +1 416.502.1950 • Fax +1 416.502.1952 info@cryocanada.com • cryoindservice.com Flow Rate – lpm 775 1160 1550 1935 2320 245 700 215 1x2x4.5 600 185 500 155 400 1.5x2.5x6A 2x4x6 2x3x6 120 300 90 200 60 100 30 0 100 200 300 Flow Rate – gpm 400 500 600 International Differential Head – meters Differential Head – feet 385 800 Australia Dandenong, Victoria, Australia +61.3.9791.7888 • Fax +61.3.9769.2788 sales.au@cryoquip.com • cryoquip.com Brasil São Paulo - SP, Brasil +55 11 2341.7474 sales.br@cryoind.com • cryoindservice.com China Hangzhou, China +86.571.8869.0788 • Fax +86.571.8869.0715 hci@mail.hz.zj.cn • cryoindservice.com Europe D-79415 Bad Bellingen Germany +49.7635.8105.0 • Fax: +49.7635.8965 info@acdcryo.com • acdcryo.com India Vadodara, Gujarat, India +91.265.283 0113 • Fax +91.265.283 0112 npatel@acdllc.com • acdcom.com Korea Yongin-si, Gyeonggi-do, Korea +82.31.286.6114 • Fax +82.31.286.6118 info@ci-korea.co.kr • cryoindservice.com Malaysia Shah Alam, Selangor D.Ehsan, Malaysia +603.5740.8770 • Fax +603.5740.8775 sales@cimalaysia.com • cryoindservice.com Bulletin No. ACD AC 18HD-R2.09