Subminiature Relays Type VTH Monostable • • • • • • Subminiature relay Switching current up to 10 A DC coils from 3 to 24 VDC 1 change-over or normally open contact Sealed as standard UL, cUL, VDE approved VT Product Description Sealed according to IP 67, suitable for automatic soldering and immersion or spray washing.Power subminiature relay for p.c. board, with one change-over contact, suita- Ordering Key ble for many electronic applications such as antitheft, automotive market, heating equipment, air conditioning, automatic dispensers, videogames, etc. VTH A 001 24 Type Version Contact code Coil rated voltage Version A = contact material Ag Cd O (standard) S = contact material Ag Sn O2 (on request) Type Selection Contact configuration 1 change over contact (SPDT {1-form C}) Contact rating Contact code 10 A 001 Coil Characteristics, DC (20°C) Operating range Rated voltage VDC 5 6 9 12 18 24 48 Winding Resistance Ω ±10% Min. pick-up voltage VDC 70 100 225 400 900 1600 4500 3.75 4.50 6.75 9.00 13.50 18.00 36.00 Max. VDC Drop-out voltage VDC 0.5 0.6 0.9 1.2 1.8 2.4 4.8 120% of rated voltage Contact Characteristics Rating Contact Material (stand. vers.) Initial contact resistance Current (for AC) Rated current with resistive load AgCdO AgSnO2 Max. switching current with resistive load Voltage Rated voltage 16-24 10 A AgCdO ≤ 100 mΩ (1A-24VDC) 7 A 250 VAC / 24 VDC 10 A 250 VAC / 24 VDC 15 A 28 VDC / 240 VAC Max. switching voltage with resistive load Max. switching power with resistive load AgCdO AgSnO2 Min. switching load (reference value) Life Electrical life Mechanical life Max. switching frequency electrical mechanical 125 VDC / 240 VAC 1750 VA 2500 VA 12 VDC 100 mA 105 cycles 1 x 107 cycles 1200 cycles/h 18000 cycles/h Specifications are subject to change without notice Subminiature Relays Type VTH Monostable General Data Insulation Test voltage (1 min.) Open cont. Coil/contacts Insulation resistance at 500 VDC Max. operating time at rated voltage (excluded bounces) Bounces time (at rated voltage) Max. release time (excluded bounces) Bounces time Ambient temperature Vibration resistance Shock resistance functional destructive Weight 750 VAC 1500 VAC > 1000 MΩ Dimensions Pin View VTH . 001 ≤ 5 ms ≤ 5 ms -40 °C - +70 °C 1,5 mm p.p., 10 + 55 Hz 100 m/s2 1000 m/s2 ~ 10 g VTH . 001 0.6 x 0.5 0.5 x 0.5 19.2 3.4 0.8 x 0.4 15.4 2 12.3 ≤ 5 ms Wiring Diagram VTH . 001 14.8 ≤ 10 ms 6 5 5 x Ø 0.9 6 Diagrams 1 Maximùm Switching Power 2 Life Curve Application notes The relays are completely sealed, suitable for automatic soldering process and immersion washing. If maximum utilization of switching capacity is requi-red, it is recommended to open the 3 Coil Temperature Approvals relay after completion of the soldering/washing process by taking the tape out of the front cover. For washing it is advisable to use alcohol, freon or (temperature must be < 50 °C). Specifications are subject to change without notice C The approvals stated are not generally applicable to all relay versions of a particular type. U.S.A. CANADA GERMANY For further information please apply for relevant data sheets ref. 3.84.00.10.X 16-25