Bulletin 331B Supplement A D VA N C E D T E C H N O L O G Y IN I N D U C E D D R A F T, C O U N T E R F L O W C O O L I N G T O W E R S TECHNOLOGY FOR THE F U T U R E ...A VA I L A B L E T O D AY ! † Mark owned by the Cooling Technology Institute † T H E A D VA N C E D T E C H N O L O G Y D E SI G N P R O V I D I N G EVAPCO, Inc., continues its dedication to advancements in induced draft, counterflow cooling tower technology and easy maintenance with the Advanced Technology Cooling Tower... The EVAPCO AT! The expanded AT line offers higher tonnage units and is designed with IBC compliance construction and CTI certified performance. Smooth Flow Fan • Soft-connect blade to hub design. • Variable Frequency Drive friendly • Eliminates critical blade passing frequencies at any speed. S ince its founding in 1976, EVAPCO, Inc. has become a world-wide leader in supplying quality cooling equipment for thousands of customers in both the commercial and industrial markets. EVAPCO’s success has been the result of a continual commitment to product improvement, quality workmanship and a dedication to providing unparalleled service. EVAPCO unequivocally guarantees the thermal performance of the AT cooling tower product line. Super Low Sound Fan • Extremely wide sloped fan blades for sound sensitive applications. • One piece molded heavy duty construction. • 9-15 dB(A) sound reduction. • Standard on UT models, available on AT and USS models. Easy Field Assembly • A new field assembly seam design which ensures easier assembly and reduced potential for field seam leaks. • Self-guided channels guide the fan casing section into position improving the quality of the field seam. • Eliminates up to 66% of fasteners compared to previous designs. Our emphasis on research and development has led to many product innovations – a hallmark of EVAPCO through the years. Louver Access Door • Standard on all 14’ x 26’ models. • Hinged access panel with quick release mechanism. • Allows easy access to perform routine maintenance and inspection of the makeup assembly, strainer screen and basin. The ongoing R & D Program enables EVAPCO to provide the most advanced products in the industry – technology for the future, available today. With 17 facilities in eight countries and over 170 sales offices in 42 countries world-wide, EVAPCO is ready to assist in all your equipment needs. Quick Connect Piping System • All inlet and outlet piping connections are beveled for welding and grooved to accept a mechanical coupling device as standard. • Facilitates easy pipe connections for quick installation. • Flanged connections are available as an option. ©2010 EVAPCO, INC. 2 † Mark owned by the Cooling Tower Institute EASIER SOLUTIONS AND BETTER CHOICES Available in multi-cell arrangements with a capacity range of 1,003 to 4,995 Nominal Tons (4,444 to 22,128 kW)! The AT has a model for every application. If there is an application for which the standard catalog product line does not work, EVAPCO will make a cooling tower that will fit your requirement! Consult your local EVAPCO Representative or the factory for all your cooling tower needs. Exclusive 5 Year Motor & Drive Warranty Optional Working Platform † CTI Certified-Standard 201 • Independent Certification. • Eliminates necessity for costly field performance tests. • Platform and ladder arrangement available as an option. • Provides additional working surface for the service mechanic. • One continuous platform on 14’ x 26’ units provides access to both fan and drive systems. • Covers the complete drive system, including the motor. • Standard on all AT Models. • Upgraded 5 year Complete Product warranty on models with optional stainless steel construction. Unique Fan Drive System L NEW • Premium efficient, inverter duty motors standard. • • • • Power-band belts for better lateral rigidity. Advanced design aluminum fan blades. Non-corroding cast aluminum sheaves. Heavy-duty fan shaft bearings with L-10 life of 75,000 - 135,000 hrs. • All other components constructed of corrosion resistant materials. • Totally enclosed fan motors assure long life. • Twin fan drives for redundancy. EvapJet™ Nozzle Water Distribution System • Non-corrosive PVC construction with EvapJet™ nozzles. • Large orifice nozzles prevent clogging and are threaded for easy removal and positive positioning. • 66% fewer nozzles! • System branches have threaded end caps to assist with debris removal. Clean Pan Sloped Basin Design EVAPCOAT Corrosion Protection System • G-235 Galvanized Steel Construction–EVAPCO set the standard with 2.35oz. of zinc per square foot of surface area. • The standard 304 stainless steel suction strainer eliminates excessive wear and corrosion. • Non-corrosive PVC Water Distribution System, Drift Eliminators and Inlet Louvers. • This system provides maximum corrosion protection as standard. 3 • Designed to completely drain the cold water basin. • Helps prevent buildup of sediment and biological film. • Eliminates standing water after drain down. E NGINEERING D ATA & D IMENSIONS MODELS: AT/UT/USS 114-526 to 114-926 Access Doors Swing Inside Unit One-Cell Cooling Towers ACCESS DOOR ACCESS DOOR 7 F ACCESS DOOR 2 T ACCESS DOOR 14 BFW/GROOVED INLET 12' 10-1/2" H P 4 FPT OVERFLOW 10' 3-3/8" 2' 2" 4 FPT DRAIN 1' 5-3/8" 3/8 ! 9 9 4-1/8" 3 MPT MAKE-UP 14 BFW/GROOVED OUTLET 6' 6-1/4" 12' 10-1/2" 13' 11-1/4" 25' 8-7/8" Weights (LBS) Dimensions Model No. Shipping Operating Heaviest Section! Fan Motor (HP) AT-114-526 AT-114-626 AT-114-726 AT-114-826 AT-114-926 24,800 24,860 24,960 25,280 25,300 41,630 41,690 41,790 42,110 42,130 17,660 17,720 17,820 18,140 18,160 (2) 20 (2) 25 (2) 30 (2) 40 (2) 50 Air Flow (CFM) H T P AT/USS UT 200,200 214,700 227,300 248,500 266,300 21’ 3/8” 21’ 3/8” 21’ 3/8” 21’ 3/8” 21’ 3/8” 10’ 9” 10’ 9” 10’ 9” 10’ 9” 10’ 9” 16’ 3-3/4” 16’ 3-3/4” 16’ 3-3/4” 16’ 3-3/4” 16’ 3-3/4” 1’ 3-1/4” 1’ 3-1/4” 1’ 3-1/4” 1’ 3-1/4” 1’ 3-1/4” 2’ 6-3/4” 2’ 6-3/4” 2’ 6-3/4” 2’ 6-3/4” 2’ 6-3/4” F NOTE: (1) An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water. (2) Do not use catalog drawings for certified prints. Dimensions and weights are subject to change. (3) Adequate spacing must be allowed for access to the cooling tower. (4) Fan guard does not ship factory mounted. ! Outlet connection extends 3/8” beyond bottom flange. ! Heaviest section is the upper section 4 E NGINEERING D ATA & D IMENSIONS MODELS: AT/UT/USS 214-552 to 214-952 Two-Cell Cooling Towers Access Doors Swing Inside Unit ACCESS DOOR ACCESS DOOR ACCESS DOOR ACCESS DOOR 7 F ACCESS DOOR T 2 ACCESS DOOR ACCESS DOOR ACCESS DOOR (2) 14 BFW/GROOVED INLET 12' 10-1/2" H P 10' 3-3/8" 2' 2" 3/8 ! 1' 5-3/8" 9 4-1/8 (2) 4 FPT OVERFLOW (2) 4 FPT DRAIN 2-1/2 51' 8-1/4" 12' 10-1/2" 19' 2-5/8" 24' 11-7/8" 25' 8-7/8" 13' 11-1/4" Weights (LBS) (2) 3 MPT MAKE-UP (2) 14 BFW/GROOVED OUTLET Dimensions Model No. Shipping Operating Heaviest Section! Fan Motor (HP) AT-214-552 AT-214-652 AT-214-752 AT-214-852 AT-214-952 49,200 49,320 49,520 50,160 50,200 82,860 82,980 83,180 83,820 83,860 17,660 17,720 17,820 18,140 18,160 (4) 20 (4) 25 (4) 30 (4) 40 (4) 50 Air Flow (CFM) H T P AT/USS UT 393,500 422,100 446,800 488,700 523,700 21’ 3/8” 21’ 3/8” 21’ 3/8” 21’ 3/8” 21’ 3/8” 10’ 9” 10’ 9” 10’ 9” 10’ 9” 10’ 9” 16’ 3-3/4” 16’ 3-3/4” 16’ 3-3/4” 16’ 3-3/4” 16’ 3-3/4” 1’ 3-1/4” 1’ 3-1/4” 1’ 3-1/4” 1’ 3-1/4” 1’ 3-1/4” 2’ 6-3/4” 2’ 6-3/4” 2’ 6-3/4” 2’ 6-3/4” 2’ 6-3/4” F NOTE: (1) An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water. (2) Do not use catalog drawings for certified prints. Dimensions and weights are subject to change. (3) Adequate spacing must be allowed for access to the cooling tower. (4) These models are available as (2) independent operating cells. Consult the factory for details. (5) Fan guard does not ship factory mounted. ! Outlet connection extends 3/8” beyond bottom flange. ! Heaviest section is the upper section 5 E NGINEERING D ATA & D IMENSIONS MODELS: AT/UT/USS 314-578 to 314-978 Three-Cell Cooling Towers Access Doors Swing Inside Unit ACCESS DOOR ACCESS DOOR 7 ACCESS DOOR ACCESS DOOR ACCESS DOOR ACCESS DOOR F ACCESS DOOR 2 ACCESS DOOR ACCESS DOOR ACCESS DOOR ACCESS DOOR ACCESS DOOR T (3) 14 BFW/GROOVED INLET 12' 10-1/2" H P 10' 3-3/8" 2' 2" 3/8 ! 12' 10-1/2" 1' 5-3/8" (3) 4 FPT OVERFLOW (3) 4 FPT DRAIN 19' 2-5/8" 9 4-1/8 24' 11-7/8" 25' 8-7/8" (3) 14 BFW/GROOVED OUTLET (3) 3 MPT MAKE-UP 2-1/2 13' 11-1/4" 77' 7-5/8" Weights (LBS) Dimensions Model No. Shipping Operating Heaviest Section! Fan Motor (HP) AT-314-578 AT-314-678 AT-314-778 AT-314-878 AT-314-978 73,620 73,800 74,100 75,060 75,120 124,110 124,290 124,590 125,550 125,610 17,660 17,720 17,820 18,140 18,160 (6) 20 (6) 25 (6) 30 (6) 40 (6) 50 Air Flow (CFM) H T P AT/USS UT 586,300 628,800 665,700 728,100 780,300 21’ 3/8” 21’ 3/8” 21’ 3/8” 21’ 3/8” 21’ 3/8” 10’ 9” 10’ 9” 10’ 9” 10’ 9” 10’ 9” 16’ 3-3/4” 16’ 3-3/4” 16’ 3-3/4” 16’ 3-3/4” 16’ 3-3/4” 1’ 3-1/4” 1’ 3-1/4” 1’ 3-1/4” 1’ 3-1/4” 1’ 3-1/4” 2’ 6-3/4” 2’ 6-3/4” 2’ 6-3/4” 2’ 6-3/4” 2’ 6-3/4” F NOTE: (1) An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water. (2) Do not use catalog drawings for certified prints. Dimensions and weights are subject to change. (3) Adequate spacing must be allowed for access to the cooling tower. (4) These models are available as (3) independent operating cells. Consult the factory for details. (5) Fan guard does not ship factory mounted. ! Outlet connection extends 3/8” beyond bottom flange. ! Heaviest section is the upper section 6 E NGINEERING D ATA & D IMENSIONS MODELS: AT/UT/USS 228-526 to 228-926 Access Doors Swing Inside Unit Two-Cell Cooling Towers ACCESS DOOR ACCESS DOOR ACCESS DOOR ACCESS DOOR 7 F ACCESS DOOR T (2) 14 BFW/GROOVED INLET ACCESS DOOR 2 6' 11-5/8" H P 10' 3-3/8" 2' 2" (2) 4 MPT OVERFLOW (2) 3 MPT MAKE-UP (2) 4 MPT DRAIN 5-1/8 28' 3-5/8" (2) 14 BFW/GROOVED OUTLET 11' 6" 13' 1-1/4" 13' 5-1/2" 13' 6-1/2" 13' 11-1/4" 1' 5-3/8" 4 9 ! 3/8 25' 8-7/8" Weights (LBS) Dimensions Model No. Shipping Operating Heaviest Section! Fan Motor (HP) AT-228-526 AT-228-626 AT-228-726 AT-228-826 AT-228-926 48,940 49,060 49,260 49,900 49,940 82,600 82,720 82,920 83,560 83,600 17,660 17,720 17,820 18,140 18,160 (4) 20 (4) 25 (4) 30 (4) 40 (4) 50 Air Flow (CFM) H T P AT/USS UT 392,000 420,400 445,100 486,800 521,700 21’ 3/8” 21’ 3/8” 21’ 3/8” 21’ 3/8” 21’ 3/8” 10’ 9” 10’ 9” 10’ 9” 10’ 9” 10’ 9” 16’ 3-3/4” 16’ 3-3/4” 16’ 3-3/4” 16’ 3-3/4” 16’ 3-3/4” 1’ 3-1/4” 1’ 3-1/4” 1’ 3-1/4” 1’ 3-1/4” 1’ 3-1/4” 2’ 6-3/4” 2’ 6-3/4” 2’ 6-3/4” 2’ 6-3/4” 2’ 6-3/4” F NOTE: (1) An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water. (2) Do not use catalog drawings for certified prints. Dimensions and weights are subject to change. (3) Adequate spacing must be allowed for access to the cooling tower. (4) These models are available as (2) independent operating cells. Consult the factory for details. (5) Fan guard does not ship factory mounted. ! Outlet connection extends 3/8” beyond bottom flange. ! Heaviest section is the upper section 7 E NGINEERING D ATA & D IMENSIONS MODELS: AT/UT/USS 428-552 to 428-952 Four-Cell Cooling Towers Access Doors Swing Inside Unit ACCESS DOOR ACCESS DOOR ACCESS DOOR ACCESS DOOR ACCESS DOOR ACCESS DOOR ACCESS DOOR ACCESS DOOR 7 F ACCESS DOORS ACCESS DOORS ACCESS DOORS ACCESS DOORS T (4) 14 BFW/GROOVED INLET 2 6' 11-5/8" H P 10' 3-3/8" (2) 14 BFW/GROOVED OUTLET (4) 4 MPT OVERFLOW (4) 3 MPT MAKE-UP (4) 4 MPT DRAIN 5-1/8 28' 3-5/8" 11' 6" 13' 1-1/4" 13' 5-1/2" 13' 6-1/2" 13' 11-1/4" 1' 5-3/8" 9 2' 2" ! 25' 8-7/8" 3' 7" 25' 8-7/8" 3/8 4 55' 3/4" Weights (LBS) Dimensions Model No. Shipping Operating Heaviest Section! Fan Motor (HP) AT-428-552 AT-428-652 AT-428-752 AT-428-852 AT-428-952 97,960 98,200 98,600 99,880 99,960 165,280 165,520 165,920 167,200 167,280 17,660 17,720 17,820 18,140 18,160 (8) 20 (8) 25 (8) 30 (8) 40 (8) 50 Air Flow (CFM) H T P AT/USS UT 747,500 801,900 849,100 928,900 995,700 21’ 3/8” 21’ 3/8” 21’ 3/8” 21’ 3/8” 21’ 3/8” 10’ 9” 10’ 9” 10’ 9” 10’ 9” 10’ 9” 16’ 3-3/4” 16’ 3-3/4” 16’ 3-3/4” 16’ 3-3/4” 16’ 3-3/4” 1’ 3-1/4” 1’ 3-1/4” 1’ 3-1/4” 1’ 3-1/4” 1’ 3-1/4” 2’ 6-3/4” 2’ 6-3/4” 2’ 6-3/4” 2’ 6-3/4” 2’ 6-3/4” F NOTE: (1) An adequately sized bleed line must be installed in the cooling tower system to prevent build-up of impurities in the recirculated water. (2) Do not use catalog drawings for certified prints. Dimensions and weights are subject to change. (3) Adequate spacing must be allowed for access to the cooling tower. (4) These models are available as (4) independent operating cells. Consult the factory for details. (5) Fan guard does not ship factory mounted. ! Outlet connection extends 3/8” beyond bottom flange. ! Heaviest section is the upper section 8 T HERMAL P ERFORMANCE MODELS: AT/UT/USS 114-526 to 428-952 Model No. AT-114-526 AT-114-626 AT-114-726 AT-114-826 AT-114-926 AT-214-552 AT-214-652 AT-214-752 AT-214-852 AT-214-952 AT-314-578 AT-314-678 AT-314-778 AT-314-878 AT-314-978 AT-228-526 AT-228-626 AT-228-726 AT-228-826 AT-228-926 AT-428-552 AT-428-652 AT-428-752 AT-428-852 AT-428-952 Model No. AT-114-526 AT-114-626 AT-114-726 AT-114-826 AT-114-926 AT-214-552 AT-214-652 AT-214-752 AT-214-852 AT-214-952 AT-314-578 AT-314-678 AT-314-778 AT-314-878 AT-314-978 AT-228-526 AT-228-626 AT-228-726 AT-228-826 AT-228-926 AT-428-552 AT-428-652 AT-428-752 AT-428-852 AT-428-952 Motor Hp (2) 20 (2) 25 (2) 30 (2) 40 (2) 50 (4) 20 (4) 25 (4) 30 (4) 40 (4) 50 (6) 20 (6) 25 (6) 30 (6) 40 (6) 50 (4) 20 (4) 25 (4) 30 (4) 40 (4) 50 (8) 20 (8) 25 (8) 30 (8) 40 (8) 50 Motor Hp (2) 20 (2) 25 (2) 30 (2) 40 (2) 50 (4) 20 (4) 25 (4) 30 (4) 40 (4) 50 (6) 20 (6) 25 (6) 30 (6) 40 (6) 50 (4) 20 (4) 25 (4) 30 (4) 40 (4) 50 (8) 20 (8) 25 (8) 30 (8) 40 (8) 50 EWT LWT WB EWT LWT WB † Thermal performance certified by the Cooling Technology Institute (CTI) in accordance with CTI Standard STD-201 TOWER CAPABILITY IN USGPM AT THE FOLLOWING TEMPERATURE CONDITIONS (°F) 90° 95° 90° 95° 90° 95° 90° 95° 95° 80° 80° 80° 80° 80° 80° 80° 80° 85° 66° 66° 68° 68° 70° 70° 72° 72° 75° 3,777 3,076 3,536 2,869 3,195 2,611 2,840 2,355 3,571 4,037 3,302 3,784 3,086 3,429 2,814 3,054 2,543 3,821 4,258 3,497 3,995 3,270 3,626 2,987 3,238 2,705 4,033 4,623 3,816 4,345 3,577 3,953 3,276 3,544 2,975 4,386 4,919 4,077 4,631 3,827 4,221 3,514 3,792 3,197 4,672 7,431 6,043 6,956 5,636 6,281 5,126 5,579 4,621 7,025 7,944 6,492 7,444 6,063 6,741 5,528 6,001 4,994 7,517 8,383 6,877 7,862 6,429 7,133 5,868 6,366 5,311 7,937 9,106 7,507 8,555 7,037 7,780 6,441 6,971 5,844 8,635 9,692 8,024 9,120 7,530 8,310 6,911 7,459 6,285 9,203 11,075 9,001 10,365 8,395 9,357 7,633 8,309 6,880 10,469 11,841 9,672 11,094 9,031 10,043 8,232 8,939 7,436 11,202 12,496 10,246 11,718 9,578 10,630 8,741 9,484 7,909 11,830 13,576 11,188 12,753 10,487 11,595 9,595 10,387 8,705 12,872 14,452 11,959 13,598 11,222 12,387 10,297 11,116 9,363 13,722 7,404 6,019 6,930 5,614 6,257 5,105 5,557 4,601 6,999 7,915 6,467 7,417 6,039 6,715 5,505 5,977 4,973 7,489 8,353 6,851 7,833 6,404 7,106 5,845 6,341 5,289 7,909 9,074 7,480 8,525 7,011 7,751 6,416 6,945 5,821 8,604 9,659 7,995 9,089 7,502 8,281 6,885 7,432 6,260 9,171 14,144 11,458 13,215 10,672 11,912 9,701 10,560 8,726 13,350 15,134 12,325 14,169 11,496 12,803 10,462 11,379 9,440 14,308 15,979 13,063 14,975 12,201 13,563 11,127 12,077 10,052 15,121 17,380 14,290 16,314 13,375 14,815 12,224 13,243 11,080 16,470 18,520 15,289 17,408 14,333 15,838 13,128 14,198 11,919 17,570 100° 85° 75° 2,922 3,142 3,329 3,639 3,892 5,741 6,175 6,545 7,159 7,659 8,551 9,198 9,750 10,668 11,415 5,718 6,151 6,519 7,132 7,631 10,877 11,709 12,428 13,614 14,580 TOWER CAPABILITY IN USGPM AT THE FOLLOWING TEMPERATURE CONDITIONS (°F) 95° 100° 95° 97° 100° 102° 95° 97° 100° 85° 85° 85° 87° 85° 87° 85° 87° 85° 76° 76° 78° 78° 78° 78° 80° 80° 80° 3,398 2,791 3,009 3,563 2,495 2,935 2,534 3,138 2,140 3,639 3,002 3,233 3,813 2,691 3,155 2,732 3,368 2,314 3,845 3,184 3,425 4,025 2,859 3,343 2,902 3,564 2,466 4,187 3,487 3,740 4,377 3,141 3,654 3,186 3,887 2,719 4,465 3,731 3,997 4,663 3,371 3,907 3,419 4,152 2,926 6,680 5,480 5,913 7,010 4,900 5,766 4,975 6,167 4,198 7,159 5,898 6,356 7,501 5,284 6,202 5,365 6,621 4,541 7,566 6,259 6,734 7,920 5,618 6,572 5,701 7,010 4,842 8,241 6,856 7,357 8,617 6,172 7,187 6,263 7,649 5,338 8,791 7,340 7,867 9,185 6,626 7,689 6,721 8,172 5,749 9,952 8,161 8,807 10,446 7,296 8,588 7,408 9,185 6,250 10,669 8,785 9,470 11,178 7,868 9,238 7,989 9,864 6,760 11,275 9,324 10,032 11,805 8,368 9,791 8,492 10,447 7,208 12,283 10,214 10,964 12,846 9,193 10,711 9,329 11,400 7,949 13,105 10,939 11,725 13,694 9,872 11,460 10,013 12,181 8,564 6,654 5,458 5,889 6,983 4,879 5,743 4,954 6,142 4,180 7,133 5,874 6,332 7,473 5,262 6,177 5,343 6,595 4,521 7,538 6,235 6,708 7,892 5,595 6,546 5,678 6,984 4,821 8,211 6,829 7,330 8,587 6,147 7,161 6,238 7,621 5,316 8,760 7,313 7,838 9,153 6,600 7,661 6,695 8,143 5,726 12,687 10,371 11,211 13,320 9,254 10,926 9,403 11,693 7,907 13,615 11,182 12,059 14,277 10,000 11,759 10,153 12,574 8,575 14,402 11,869 12,790 15,088 10,636 12,481 10,800 13,321 9,143 15,704 13,022 14,003 16,435 11,702 13,671 11,876 14,561 10,102 16,773 13,970 14,984 17,534 12,584 14,638 12,765 15,573 10,894 ASHRAE STD 90.1 Rating (gpm/Hp) 89.28 76.42 67.22 54.82 46.72 87.81 75.17 66.14 53.97 46.02 87.24 74.68 65.72 53.63 45.74 87.48 74.89 65.90 53.78 45.86 83.44 71.54 63.00 51.47 43.93 102° 87° 80° 2,607 2,811 2,983 3,272 3,510 5,119 5,521 5,861 6,433 6,903 7,623 8,221 8,730 9,583 10,284 5,098 5,498 5,838 6,408 6,876 9,688 10,448 11,113 12,208 13,112 To Make a Selection: Locate the column with the desired operating temperature conditions. Read down the column until you find the GPM equal to or greater than the flow required. Read horizontally to the left to find the model number of the unit that will perform the duty. For selections and conditions other than those stated, consult your evapSelect™ Program or local EVAPCO representative. † Mark owned by the Cooling Technology Institute 9 S TRUCTURAL S TEEL S UPPORT Models AT/UT/USS 114-526 to 314-978 Suggested Two I-Beam Arrangement Two I-Beams Required (By Others) Dimensions End Elevation Model No. W L 114-526 to 926 214-552 to 952 314-578 to 978 13’ 11-1/4” 13’ 11-1/4” 13’ 11-1/4” 25’ 8-7/8” 51’ 8-1/4” 77’ 7-5/8 Plan View Models AT/UT/USS 228-526 to 428-952 Suggested Three I-Beam Arrangement Three I-Beams Required (By Others) Dimensions Model No. W L 228-526 to 926 424-552 to 952 28’ 3-5/8” 28’ 3-5/8” 25’ 8-7/8” 55’ 3/4” End Elevation Plan View Notes: 1. These are suggested arrangements for preliminary layout purposes. Consult your EVAPCO representative for factory certified steel support drawings. 2. The recommended support for the AT/UT/USS Cooling Tower is structural I-beams located under the outer flanges and running the entire length of the unit. The unit should be elevated to allow access underneath the unit and to the roof below. Mounting holes, 3/4” in diameter, are located in the bottom flanges of the pan to provide for bolting to the structural steel. 3. Beams should be sized in accordance with accepted structural practices. Maximum deflection of beam under unit to be 1/360 of the unit length, not to exceed 1/2”. 4. For models where two support beams are required, deflection may be calculated by using 55% of the operating weight as a uniform load on each beam. 5. For models where three support beams are required, deflection may be calculated by using 56% of the operating weight on the CENTER BEAM and 22% on each OUTBOARD BEAM. 6. Beams should be level before setting the unit in place. Do not level the unit by shimming between it and the I-beams. 7. Support beams and Anchor bolts are to be furnished by others. 8. Dimensions, weights and data are subject to change without notice. Refer to the factory certified drawings for exact dimensions. 9. For alternate layout arrangements please consult the factory. NOTE: OPTIONAL BOTTOM CONNECTIONS WILL REQUIRE THE UNIT TO BE ELEVATED TO ALLOW FOR PIPING. 10 Drain Down Volume for Remote Sump Applications The following chart provides the maximum drain down volume allowable per AT/UT/USS model number. Use this chart when sizing indoor or outdoor remote sumps tanks. Remote sump applications are commonly used whenever a cooling tower is idle during sub-freezing weather to protect the water in the basin from freezing or for large multi-tower industrial applications. Either application allows the circulating water to gravity drain into a remote sump tank indoors or a large, outdoor concrete basin located underneath the cooling tower. The water volume provided is the cooling tower portion of the remote sump tank only. The tank should allow for drain down water from external piping and pump suction coverage. Model Maximum Drain Down Volume 114-526 to 114-926 214-552 to 214-952 314-578 to 314-978 228-526 to 228-926 428-552 to 428-952 2,325 4,650 6,975 4,050 9,300 Platform & Ladder for Improved Drive System Access Available as an option, one continuous platform provides easy access to both fan and drive systems. 11 ® E VA P C O P R O D U C T S ARE M A N U FA C T U R E D W O R L D W I D E . W World Headquarters/ Research and R Development Center D EVAPCO Facilities EVAPCO, Inc. — World Headquarters & Research/Development Center EVAPCO, Inc. • P.O. Box 1300 • Westminster, MD 21158 USA PHONE: 410-756-2600 • FAX: 410-756-6450 • E-MAIL: marketing@evapco.com EVAPCO North America EVAPCO, Inc. World Headquarters P.O. Box 1300 Westminster, MD 21158 USA Phone: 410-756-2600 Fax: 410-756-6450 E-mail: marketing@evapco.com EVAPCO East 5151 Allendale Lane Taneytown, MD 21787 USA Phone: 410-756-2600 Fax: 410-756-6450 E-mail: marketing@evapco.com EVAPCO Midwest 1723 York Road Greenup, IL 62428 USA Phone: 217-923-3431 Fax: 217-923-3300 E-mail: evapcomw@evapcomw.com EVAPCO West 1900 West Almond Avenue Madera, CA 93637 USA Phone: 559-673-2207 Fax: 559-673-2378 E-mail: contact@evapcowest.com EVAPCO Europe Refrigeration Valves & Systems Corporation A wholly owned subsidiary of EVAPCO, Inc. 1520 Crosswind Dr. Bryan, TX 77808 USA Phone: 979-778-0095 Fax: 979-778-0030 E-mail: rvs@rvscorp.com McCormack Coil Company, Inc. A wholly owned subsidiary of EVAPCO, Inc. P.O. Box 1727 6333 S.W. Lakeview Boulevard Lake Oswego, OR 97035 USA Phone: 503-639-2137 Fax: 503-639-1800 E-mail: mail@mmccoil.com EvapTech, Inc. A wholly owned subsidiary of EVAPCO, Inc. 8331 Nieman Road Lenexa, KS 66214 USA Phone: 913-322-5165 Fax: 913-322-5166 E-mail: marketing@evaptech.com Tower Components, Inc. A wholly owned subsidiary of EVAPCO, Inc. EVAPCO Iowa 925 Quality Drive Lake View, IA 51450 USA Phone: 712-657-3223 Fax: 712-657-3226 5960 US HWY 64E Ramseur, NC 27316 Phone: 336-824-2102 Fax: 336-824-2190 E-mail: mail@towercomponentsinc.com EVAPCO Iowa Sales & Engineering 1234 Brady Boulevard Owatonna, MN 55060 USA Phone: 507-446-8005 Fax: 507-446-8239 E-mail: evapcomn@evapcomn.com EVAPCO Newton 701 East Jourdan Street Newton, IL 62448 USA Phone: 618-783-3433 Fax: 618-783-3499 E-mail: evapcomw@evapcomw.com EVAPCO...SPECIALISTS IN HEAT TRANSFER PRODUCTS AND SERVICES. 1500/0910/YGS Visit EVAPCO’s Website at: EVAPCO Europe, N.V. European Headquarters Industrieterrein Oost 4010 3700 Tongeren, Belgium Phone: (32) 12-395029 Fax: (32) 12-238527 E-mail: evapco.europe@evapco.be EVAPCO Europe, S.r.l. Via Ciro Menotti 10 I-20017 Passirana di Rho Milan, Italy Phone: (39) 02-939-9041 Fax: (39) 02-935-00840 E-mail: evapcoeurope@evapco.it EVAPCO Europe, S.r.l. Via Dosso 2 23020 Piateda Sondrio, Italy EVAPCO Europe, GmbH Bovert 22 D-40670 Meerbusch, Germany Phone: (49) 2159-69560 Fax: (49) 2159-695611 E-mail: info@evapco.de Flex coil a/s A wholly owned subsidiary of EVAPCO, Inc. Knøsgårdvej 115 DK-9440 Aabybro Denmark Phone: (45) 9824 4999 Fax: (45) 9824 4990 E-mail: info@flexcoil.dk EVAPCO S.A. (Pty.) Ltd. A licensed manufacturer of EVAPCO, Inc. 18 Quality Road Isando 1600 Republic of South Africa Phone: (27) 11-392-6630 Fax: (27) 11-392-6615 E-mail: evapco@evapco.co.za Evap Egypt Engineering Industries Co. 5 El Nasr Road, Nasr City, Cairo, Egypt Phone: +2 (02) 24022866/+2 (02) 24044997/8 Fax: +2 (02) 24044667/8 Mobile: +2 (012) 3917979 E-mail: Primacool@link.net / Shady@primacool.net / Shady@primacool.com Website: www.Tibagroup.me http://www.evapco.com EVAPCO Asia/Pacific EVAPCO Asia/Pacific Headquarters 1159 Luoning Rd. Baoshan Industrial Zone Shanghai, P. R. China, Postal Code: 200949 Phone: (86) 21-6687-7786 Fax: (86) 21-6687-7008 E-mail: marketing@evapcochina.com Evapco (Shanghai) Refrigeration Equipment Co., Ltd. 1159 Louning Rd., Baoshan Industrial Zone Shanghai, P.R. China, Postal Code: 200949 Phone: (86) 21-6687-7786 Fax: (86) 21-6687-7008 E-mail: marketing@evapcochina.com Beijing EVAPCO Refrigeration Equipment Co., Ltd. Yan Qi Industrial Development District Huai Rou County Beijing, P.R. China, Postal Code: 101407 Phone: (86) 10 6166-7238 Fax: (86) 10 6166-7395 E-mail: evapcobj@evapcochina.com Evapco Australia (Pty.) Ltd. 34-42 Melbourne Road P.O. Box 436 Riverstone, N.S.W. Australia 2765 Phone: (61) 2 9627-3322 Fax: (61) 2 9627-1715 E-mail: sales@evapco.com.au EvapTech Asia Pacific Sdn. Bhd A wholly owned subsidiary of EvapTech, Inc. IOI Business Park, 2/F Unit 20 Persiaran Puchong Jaya Selatan Bandar Puchong Jaya, 47170 Puchong, Selangor, Malaysia Phone: (60-3) 8070 7255 Fax: (60-3) 8070 5731 E-mail: marketing-ap@evaptech.com Bulletin 331B Supplement