Free-Stand Cabinets Liquid-Cooled Cabinets Networking Free-Stand Cabinets Liquid-Cooled Cabinets Spec-00555 E 763.422.2661 763.422.2588 VARISTAR LHX INDUSTRY STANDARDS SPECIFICATIONS NEMA Type 12 IP 55 • • • APPLICATION ormed steel frame, top, base and sides F S eamless foam gaskets on doors Left-mounted, water-cooled heat exchanger has 20 or 40 kW cooling capacity 115 VAC input Standard NEMA 15R plug on a 6-ft. cord R J 45 internet connection R S 232 port 1-in. copper water and condensation fittings (NPT) located at the bottom of the heat exchanger Static load rating of 400 kg (880 lb.) for 19-in. equipment VARISTAR LHX is a sealed, self-contained cabinet with an internal air-to-water heat exchanger which uses water to remove heat from the cabinet. Completely sealed from outside air and contaminants, this cabinet is ideal for high-density network, industrial and remotely located equipment. The cabinet provides up to 20 kW of heat dissipation from internal 19-in. rack-mounted equipment. The sealed design significantly reduces acoustic noise from internally mounted equipment. • • • • • FEATURES RAL 7021 black textured, low-gloss polyester powder paint over pretreated steel. • • • • • • • • • • • afety glass window door opens 180 degrees with multi-point S latch system and central key lock (key code 333) Solid steel rear door opens 180 degrees with 4-point vault locking system and central key lock Removable panels on sides Die cast metal posts on all corners of plinth base Two sets of painted rack angles included EIA spaced .375-in. square holes (42 RU spaces) 100-mm plinth base with removable side panels E asy-to-replace multiple fan construction Local monitoring displays condensation, temperature, humidity, fan failure, access, and inlet and outlet water temperature Additional connections available for other monitoring devices All exterior panels and doors cable grounded • FINISH ACCESSORIES CABLETEK™â€…Horizontal Cable Manager Rack- and Panel-Mount Power Distribution Units (PDUs) Tool-less Shelf Tool-less (Snap-in) Blanking Panels for 19-in. Racks Bulletin: DPSR Standard Product Catalog Number DV218012LX2 DV218012LX4 1 AxBxC in./mm 82.68 x 31.50 x 47.24 2100 x 800 x 1200 82.68 x 31.50 x 47.24 2100 x 800 x 1200 Networking VAC 115 Hz 50/60 Phase 1 Full Load Amps 8.6 Max. Cooling 20 kW Water Inlet Temp. 7-15 C (45-60 F) Airflow Max. m3/hr. 3,000 (1,766 CFM) Rack Units 42 115 50/60 1 12.4 40 kW 7-15 C (45-60 F) 4,200 (2,472 CFM) 42 SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION SOLUTIONS Spec-00555 E Free-Stand Cabinets Liquid-Cooled Cabinets 47.28 1201 mm 31.50 800 mm 42 RU 73.5 1867 mm 10.8 275 mm EQUIPMENT PROTECTION SOLUTIONS Spec-00555 E 19 483 mm 83.11 2111 mm 87951038 7.12 180 mm 37 MAX / 22 MIN 950 mm / 550 mm PH 763.422.2661 • FAX 763.422.2588 • HOFFMANONLINE.COM Networking 2 Free-Stand Cabinets Liquid-Cooled Cabinets 3 Networking SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION SOLUTIONS Spec-00555 E Free-Stand Cabinets Liquid-Cooled Cabinets Varistar_Features EQUIPMENT PROTECTION SOLUTIONS Spec-00555 E PH 763.422.2661 • FAX 763.422.2588 • HOFFMANONLINE.COM Networking 4 Free-Stand Cabinets Liquid-Cooled Cabinets LHX 20 Usable Cooling Capacity (at constant incoming air temperature of 104°F (40°C)) 45 46 48 50 52 54 55 57 kW 59 °F 20 kW 20 at 9 9 18 at 5 5 16 ft 3/ ft 3/ hr ( hr ( 1.55 14 2.80 18 m 3/ hr) wat er 16 m 3/ hr) wat er 14 12 12 10 10 7 8 9 10 11 12 Water Flow Temperature 13 14 15 °C Air Exit Temperature (at constant incoming air temperature of 104°F (40°C)) 45 46 48 50 52 54 55 57 °C 59 °F °F 26 79 24 55 (1. 3 /hr t f 5 at 5 22 75 3 er wat ) r 3 /h 0m 72 2.8 hr ( / 9 ft 9 t a 20 68 18 64 10 50 7 5 er wat ) r h m/ 3 Networking 8 9 10 11 12 Water Flow Temperature SUBJECT TO CHANGE WITHOUT NOTICE 13 14 15 °C EQUIPMENT PROTECTION SOLUTIONS Spec-00555 E Free-Stand Cabinets Liquid-Cooled Cabinets LHX 20 LHX 20 Diagram of Cold Air Temperature/Cooling Capacity °F °C 90 32 Water valve 100% open=99 ft3/hr (2.8 m3/hr) fan speed 100% Cooling Air Temperature 86 30 H2O=68°F (20°C) Temperature Difference ΔT (H2O) K 7.50 H2O=63°F (17°C) H2O=59°F (15°C) H2O=54°F (12°C) H2O=50°F (10°C) Control range is via water volume, 82 28 fan speed constant 80% 79 26 H2O=46°F (8°C) H2O=45°F (7°C) 75 24 H2O=43°F (6°C) 72 22 3.50 64 18 /+; 61 16 2.50 ΔT (H2O) characteristic for 99 ft3/hr (2.8 m3/hr) 0 1 2 3 EQUIPMENT PROTECTION SOLUTIONS Spec-00555 E 5.50 4.50 68 20 57 14 6.50 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 kW Cooling Capacity with Various Water Temperatures PH 763.422.2661 • FAX 763.422.2588 • HOFFMANONLINE.COM 1.50 Networking 6 Free-Stand Cabinets Liquid-Cooled Cabinets LHX 40 Usable Cooling Capacity at 10 38 36 34 32 30 28 26 24 22 20 18 16 °C °F at 71 °C °F 42 108 40 104 6 ft 3/ ft 3/hr hr (3 (2 m 3 /hr) w ater 3 hr (2 m 1 ft / mp at 7 e T t le t ou 3 Air 38 100 36 97 34 93 32 90 30 86 28 82 26 79 24 75 22 72 20 68 m 3/h r) wa ter /hr) 3 let Tem Air Out hr) r (3 m / 3 6 ft /h p at 10 6 7 8 9 10 11 12 13 14 15 16 17 18 19 18 16 20 43 45 46 48 50 52 54 55 57 59 61 63 64 66 68 Air Outlet Temperature Cooling Capacity kW 42 40 64 61 Water Pre-run Temperature °F °C 79 26 LHX 40 Diagram of Cold Air Temperature/Cooling Capacity H2O=64°F (18°C) Adjustment range of water flow valve (fan speed constant at 80%) 77 25 75 24 H2O=59°F (15°C) H2O=54°F (12°C) H2O=50°F (10°C) H2O=45°F (7°C) 73 23 H2O=43°F (6°C) Cooling Air Temperature 72 22 70 21 68 20 66 19 64 18 LHX 40 63 17 Maximum water flow rate 152 ft3/hr (4.3 m3/hr) 61 16 59 15 57 14 0 5 10 15 20 25 30 35 Cooling Capacity with Various Water Temperatures 7 H2O=46°F (8°C) Networking SUBJECT TO CHANGE WITHOUT NOTICE 40 45 50 kW EQUIPMENT PROTECTION SOLUTIONS Spec-00555 E Free-Stand Cabinets Liquid-Cooled Cabinets Technical Data Cooling Capacity Adjustment range air outlet temperature LHX 20 64.4 to 86.0 F (0.2 F increments) LHX 40 64.4 to 86.0 F (0.2 F increments) Technical Data Water Circuit Cooling medium1 Water inlet temperature2 Water flow volume Static pressure loss in device at 6.8 gal./min. Water conduit Water connection inlet/outlet Condensate drain LHX 20 Water 42.8 to 59.0 F up to 12.36 gal./min. 7.25 PSI Copper Rp 1 in. Rp 1/2 in. LHX 40 Water 42.8 to 59.0 F 18.9 gal./min. 7.25 PSI Copper Rp 1 in. Rp 1/2 in. For optimal operation of the air/water heat exchanger, the water quality requirements must be fulfilled (VDE 3803, please see user manual). 1 At a water inlet temperature below 42.8 F and above 59.0 F, the control accuracy cannot be guaranteed. There is also a risk of condensation if the water temperature falls short of the given limits. 2 Technical Data Air Loop LHX 20 1765 CFM 64.4 to 86.0 F Maximum airflow volume, controlled temperature dependently Air outlet LHX 20 (adjustable) LHX 40 2,354 CFM 64.4 to 86.0 F Technical Data Electrical Data AC Maximum current consumption Maximum power consumption Apparent power at full load Pre-fuse (in the building) LHX 20 8.6 A 700 W 990 VA 10 A LHX 40 10.4 A 1200 W 1610 VA 10 A Technical Data Interface ST-bus (RJ 45) RS 232 (SUB-D 9-pin) Digital input/output (SUB-D 25-pin) LHX 20 and LHX 40 Connection possibility for external operation and digital display ASCII protocol, all operational values and status reports, such as temperature, humidity levels, fan operation times External on/off, alarm outputs and warning signals Technical Data General Data General Data Cabinet type of protection Ambient temperature during transport Ambient temperature outside cabinet (during operation) Noise level (closed cabinet) at 80 percent fan speed Relative humidity level Weight of LHX 20 (heat exchanger) Weight of LHX 20 with cabinet (approximate) EQUIPMENT PROTECTION SOLUTIONS Spec-00555 E LHX 20 IP55, Type 12 -13 to +158 F 41 to 158 F 50.7 dB(A) 5 to 95 percent 173 lb. (181 lb. with water) 750 lb. PH 763.422.2661 • FAX 763.422.2588 • HOFFMANONLINE.COM LHX 40 IP55, Type 12 -13 to +158 F 41 to 158 F 61 dB(A) 5 to 95 percent 242 lb. 816 lb. Networking 8