el lev s uid rol Liq ont c Liquid Level Control LLC4 Series Single Probe Description The LLC4 combines resistance sensing circuitry with solid state timing to provide single probe level maintenance. On adjustable units, the sensitivity adjustment allows accurate level sensing while ignoring foaming agents and floating debris. Isolated AC voltage is provided at the probe to prevent electrolysis. A trickle current of less than 1 mA determines the presence or absence of conductive liquid between the probe and common. The LLC4 Series can be used with many types of low voltage (resistance changing) transducers to perform other control functions like temperature limit control, photo limit control, condensation sensing, and ice sensing. Operation Single Probe Level Control for Conductive Liquids Adjustable or Fixed Sensing up to 250 KΩ Selectable or Fixed Fill or Drain Operation available 24, 120, or 230 V AC Models are Available Adjustable or Fixed Time Delay Prevents Rapid Cycling Isolated AC Voltage on the Probes 10 A Resistive SPDT Isolated Contacts Approvals: Drain (Pump Down Mode): When the liquid level rises and touches the probe, the time delay begins. This time delay prevents rapid cycling of the output relay and its load. At the end of the time delay, the output relay and LED energize and remain energized until the liquid level falls below the probe level. The output relay and LED de-energize and remain de-energized until the liquid rises and touches the probe. To select this operation, the selector knob must be rotated fully clockwise. Fill (Pump Up Mode): When the liquid level falls below the probe, the time delay begins. This time delay prevents rapid cycling of the output relay and its load. At the end of the time delay, the output relay and LED energize and remain energized until the liquid level rises and touches the probe. The output relay and LED then de-energize and remain de-energized until the liquid level again falls below the probe level. To select this operation, the selector knob must be rotated fully counterclockwise. Connection Adjusting Sensitivity: On adjustable units increase the sensitivity setting to sense (control) less conductive liquids. For example: pure water exhibits low conductivity, requiring a higher sensitivity setting. Relay contacts are isolated. Dashed lines are internal connections. Connect common to conductive tank. Additional probe is necessary for non-conductive or insulated tanks. P = Probe C = Probe Common LED Operation with Diagnostics Accessories Panel mount kit P/N: BZ1 Octal 8 pin socket P/N: NDS-8 Indicating Operation Type Relay Energized & Conducting Blinks OFF Relay Energized ON steady Standard Operation Time Diagram V = Voltage With Diagnostics (D-Suffix) Conducting or Timing Flashing Relay De-energized Power Applied & Double Blink Not Conducting Relay De-energized Ordering Table Hold down clips P/N: PSC8 LLC4 Series X Input X Time Delay (Seconds) –2 - 24 V AC –A - Drain –Specify fixed delay –4 - 120 V AC –B - Fill (1 ... 60) secs. in –6 - 230 V AC –S - Selectable 1 s increments on unit Electrode P/N: PHST-38QTN X Operation X Sense Resistance X LED Operation –A - Adjustable (1...250k) –Blank - Standard LED Operation –F - Fixed –D - LED Operation with Specify fixed Diagnostics resistance (1 ... 250) in 1K Ω increments 9.6 1TRC 001 009 C0202 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • Technical assistance 800-377-7722 • www.ssac.com LLC42B03 See accessory pages for specifications. LLC44S5AD - 120VAC, selectable fill or drain operation, time delay fixed - 5 s, adjustable sensing resistance, LED operation w/ diagnostics LLC44A5A - 120VAC, drain operation, time delay fixed - 5 s, adjustable sensing resistance (1...250K ohms) LLC42S5F50D - 24VAC, selectable fill or drain, time delay fixed - 5 s, sensing resistance fixed - 50k ohms, LED operation w/ diagnostics 05.06.10 Example P/N: Level probe P/N: LLP-24 Liq u co id l nt ev ro el ls Liquid Level Control LLC4 Series Single Probe Technical Data Control Type Sensing Voltage Sensing Resistance Sensing Resistance Tolerance Operation Selection Time Delay Range Input Voltage Tolerance ON/OFF (Single Level) Resistance sensor with built-in time delay to prevent rapid cycling Low voltage AC between probe and common. Isolated from Input and Output. Factory fixed or adjustable to 250K Ω Adjustable - guaranteed range Factory fixed +/-10% or 500 ohms whichever is greater Factory fixed or adjustable - Drain = rotate fully clockwise; Fill = rotate fully counter-clockwise; Partial rotation (15% to 85%) rotation of selector dial should be voided Fixed 1...60 s in 1 s increments (see Ordering Table) 24 V AC 120 & 230 V AC Frequency Output Type Form Rating Max. Switching Voltage Life (Operations) Protection Surge Isolation Voltage Mechanical Mounting Termination Package Environmental Operating Temperature (Surrounding air) Storage Temperature Weight 24, 120, or 230 V AC -15% ... +20% -20% ... +10% 50 ... 60 Hz Isolated relay contacts Single pole double throw SPDT 10 A resistive at 125 V AC 5 A resistive at 240 V AC & 28 V DC 1/4 hp at 125 V AC 250 V AC Mechanical - 1 x 107; Electrical - 1 x 105 IEEE C62.41-1991 Level A ≥ 1500 V RMS between input, output, & probe Accessory octal socket (NDS-8 or equivalent) required 8 Pin plug-in 2.91 x 2.39 x 1.78 in. (73.9 x 60.7 x 45.2 mm) -25°C ... +60°C -40°C ... +80°C ≅ 6 oz (170 g) Diagnostic LED Operation - LLC4 Operation Level Diagram LED Operation or Mode Level of Liquid Power Applied & Relay De-energized Drain Fill 6 N/A Low liquid level, not touching probe, end of time delay & drain cycle N/A Conducting & Relay De-energized Drain Fill N/A 1 N/A High liquid level, touching probe, end of time delay & fill cycle Relay Energized & Not Conducting Drain Fill 5 to 6 3 Time delay in progress, liquid level dropping Low liquid level, not touching low probe, beginning fill cycle Relay Energized & Conducting Drain Fill 5 2 Liquid touching probe, start of drain cycle Liquid touching probe, time delay in progress, liquid level rising Mechanical View Level Diagrams LLC42B03 1 2 4 5 3 6 05.06.10 Inches (Millimeters) Low Voltage Products & Systems ABB Inc. • 888-385-1221 • Technical assistance 800-377-7722 • www.ssac.com 9.7 1TRC 001 009 C0202