RUGGED SYSTEMS

advertisement
DR-45 Guide rail type switch power supply
Features:
For AC power supply input global
Protection characteristics: short circuit/overload/pressure
Air cooling
Can be installed DIN standards guide TS-35/7.5 or 15
Has the boot display (light emitting diode (led)
100% full load and machine test
model
DR-45-5
DR-45-12
DR-45-15
HDR-45-24
5V
12V
15V
24V
±2%
±1%
±1%
±1%
5A
3.5A
2.8A
2A
Output current
range
0-5A
0-3.5A
0-2.8A
0-2A
Output power
25W
42W
42W
48W
Ripple and the
noise
100mVp-p
200mVp-p
240mVp-p
480mVp-p
Dc voltage
adjustable scope
4.75-5.5V
10.8-13.2V
13.5-16.5V
21.6-26.4V
Dc output voltage
Output voltage
tolerance
Rated output
current
output
Start, rise, keep
time
800ms,60ms,100ms/230VAC Loaded with
Input voltage range 85~264 VAC47~63 Hz;choose 120~370VDC
Exchange input
current
input
efficiency
1.5 A/115 V 0.75A/ 230 V
72%
77%
Impulse current
Cold start current 28A/115V 56A/230V
Leakage current
<1mA/240VAC
Overload
protection
105%~150%
Overvoltage
protection
115%~135%
Protection
characteristics
77%
Protection way: constant current limiting automatic recovery
Protection way: cut output, restart
80%
environment
High temperature
protection
Power tube to 135 ℃, the temperature drop, cut off output automatically
after recovery
Working
temperature,
humidity
-10℃~+50℃;20%~90 %RH
Keep temperature,
humidity
-20℃~+85℃;10%~95 %RH
Vibrate resistance
10~500Hz,2G 10min./1 cycle time, 60 minutes, the axis
Compression sex
3: KVAC between input and output and input and output KVAC: 1.5 to
0.5: KVAC
Insulation
resistance
Between the input and output, the input and output, and ground: 100M
Ohms / 500VDC
Safety standards
Accord with UL508,TUV EN60950-1
EMC standard
Accord with EN55011,EN55022,EN61000-3-2,-3,EN61000-42,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2
weight
0.31Kg
packaging
48pcs/16.1Kg/1.3CUFT
security
Complies
with the
standards
other
1. All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25
℃ conditions measuring income value.
备注
2. Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair
end with 0.1 mu and 47 u when capacitance measurement.
3. Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of
the current rate.
4. The power to consider as a device installed in final equipment, this equipment must be to
make sure it’s EMC index.
Download