R274 Industrial Relays + Accessories

advertisement
R274
Industrial Relays
+ Accessories
24 V AC, 24 V DC, 230 V AC, 2 or 4 changeover
G mechanical and electrical (LED)
operating status indication
G lockable manual test button
G solder lugs
G cadmium free contacts
Part Numbers
110 015 05 14
110 015 10 14
110 015 25 14
110 015 05 12
110 015 10 12
110 015 25 12
110 015 05 14
110 015 10 14
110 015 25 14
Industrial Relay
Housing Dimensions
06
06
06
06
06
06
08
08
08
230 V AC, 4 changeover contacts
24 V AC, 4 changeover contacts
24 V DC, 4 changeover contacts
230 V AC, 2 changeover contacts
24 V AC, 2 changeover contacts
24 V DC, 2 changeover contacts
230 V AC, 4 changeover, gold contacts
24 V AC, 4 changeover, gold contacts
24 V DC, 4 changeover, gold contacts
Description
The compact pluggable industrial relay R274 is available with 2 or 4 changeover contacts and in one DC and two
AC versions each. The plugs are designed as solder lugs allowing also conventional wiring. Furthermore the relay
is provided with an electrical (LED) and a mechanical operating position indication. When raising the manual test
button the contacts get locked, so it is possible to do a circuit testing in the equipment in a powerfree mode.
Technical Data
Wiring
2 changeover contacts
Housing
housing dimensions WxHxL
weight
mounting position
mounting
type of protection (IEC 61810-7)
ambient temperature
approval pending
21.5 x 35 x 28 mm
37 g
any
pluggable
RTII - flux tight
-40 °C ... +70 °C
VDE; UL, CUR
Supply
operating voltage UB
24 V DC
24 V AC
230 V AC
making current max. 4 s
2 changeover contacts
4 changeover contacts
current consumption at UB
response voltage
release voltage
coil resistance
response time
release time
Output
Wiring
4 changeover contacts
Indication
88
7A
5A
24 V DC
36.9 mA
19.2 V DC
2.4 V DC
650 Ω 10 %
typical 15 ms
typical 10 ms
24 V AC
50 mA
19.2 V AC
7.21 V AC
184 Ω 10
output contact
contact material
switching voltage max.
2 changeover contacts
4 changeover contacts
voltage max.
continuous current max.
2 changeover contacts
4 changeover contacts
switching power
2 changeover contacts
4 changeover contacts
mechanical endurance
electrical endurance
test voltage coil/contact
2 or 4 changeover contacts
AgNi
operating position
by LED and mechanically
230 V AC
5.21 mA
184 V AC
69 V AC
14.4 kΩ 15 %
250 V AC
440 V AC
440 V AC
10 A
5A
10 A 250 V AC AC1 / 10 A 30 V DC DC1
5 A 250 V AC AC1 / 5 A 30 V DC DC1
10 x 106 switching cycles
1 x 105 switching cycles at nominal load
1.5 kV 50 Hz 1 min