metal ceilings - SAS International

metal ceilings
system 130
modular lay-in tiles (exposed grid)
SAS International +44 (0) 118 929 0900 www.sasint.co.uk
System Description
SAS System 130 is a range of lay-in tiles supported
from SAS Alugrid or SAS Tee Grid. Alugrid-Q features a
continuous linear recess with an M6 thread and negative
quirk relief detail abutting the ceiling tiles, giving a
completely flush ceiling. Alugrid-P is a plain version
without the threaded recess and gives a completely
flush ceiling. Tee Grid is a butt cut exposed grid that
provides a tegular effect.
System Features
• Easy access to the ceiling void
• Minimum 25-year product life expectancy
System Features with SAS Alugrid
• Shadow line feature between grid and tile
• Precise mitred joints
• Continuous linear thread form
• Clean flush ceiling plane
System Features with SAS Tee Grid
• Strong modular appearance
• Butt cut junctions eliminating corner shadows
Access
Tiles can be lifted out of the ceiling system to gain access
to the ceiling void.
Standard Module Sizes (mm)
500 x 500
600 x 600 750 x 750
system 130 information
Special sizes are available on request. Please contact our
technical department for further details. 300 x 300mm
tiles can be supplied for use with SAS Tee Grid or tartan
grid configurations.
Finish
Polyester Powder coated supplied as standard with
a RAL 9010 smooth finish; a fine textured finish
(SAS FT), anti-bacterial coating (SAS AB) and other
colours are available. See page 36 for a full range of
paint finish options.
Grid System
Lay-in SAS Alugrid-Q, SAS Alugrid-P, SAS Alugrid
Cleanseal, SAS Tee Grid, see page 146 for components.
Shape
Tiles are square with out-turned flanges laid onto the
exposed grid system.
Perforation
Typically supplied with 1522, 1820 or 2516 perforation.
See page 103 for full details and perforation options.
Integration
Apertures can be formed during manufacturing for
luminaires and other services, see pages 38–39 for
further details.
Weight
Approximately 5kg/m² for 8mm steel tiles, acoustic/
insulation pad and SAS Tee Grid. Approximately
7.5kg/m² for 16mm steel tiles, acoustic pad and SAS
Alugrid suspension.
SAS International +44 (0) 118 929 0900 www.sasint.co.uk/system130
5
8
1200 / 1500mm*
4
6
3
7
1
300mm
max
9
2
1] Emac Hanger
2] Emac Hanger Bracket
6] Perimeter Trim 7] Perimeter Wedge
3] Main Runner
8] Corner Splice
4] Double Module Cross Tee
9] System 130 Tile
5] Single Module Cross Tee
*Lightweight installations only, see page 161 for full details.
Emac suspension components can be found on page 144, System 130 / SAS Tee Grid / Alugrid component details can be found on
page 146. Perimeter trims and accessories can be found on page 115.
44 / 51mm
Section Drawing
4/5
9
Acoustic Performance Data
Attenuation
Absorption
Class
NRC
αω
dB
8mm, 16mm, 19mm plain tile.
43
8mm, 16mm, 19mm perforated tile with acoustic
fleece.
13
8mm perforated tile with 8mm x 80kg/m³ acoustic
pad, factory sealed.
21
16mm perforated tile with 16mm x 80kg/m³ acoustic
pad, factory sealed.
27
16mm perforated tile with 16mm x 80kg/m³ acoustic
pad and steel backing plate.
41
19mm perforated tile with 19mm x 80kg/m³ acoustic
pad, factory sealed.
30
19mm perforated tile with 6mm x 80kg/m³ acoustic
pad and 12.5mm plasterboard.
45
N/A
Class C
0.70 0.65
Class C
0.80 0.75
Class B
0.85 0.85
Class D
0.65 0.50
Class A
0.85 0.90
Class D
0.65 0.55
Results above extracted from tests undertaken using perforation reference S1820.
SAS International +44 (0) 118 929 0900 www.sasint.co.uk/system130
system 130 technical
300mm
max
SAS Alugrid-Q 15/08
44
Tile Size (mm)
484 x 484
584 x 584
734 x 734
8
Module Size (mm)
500 x 500
600 x 600
750 x 750
15
Tile Size
Module Size
SAS Alugrid-Q 15/16
51
Tile Size (mm)
484 x 484
584 x 584
734 x 734
16
Module Size (mm)
500 x 500
600 x 600
750 x 750
15
Tile Size
Module Size
51
Tile Size (mm)
484 x 484
584 x 584
734 x 734
19
Module Size (mm)
500 x 500
600 x 600
750 x 750
15
Tile Size
Module Size
SAS Alugrid-Q 25/16
Tile Size (mm)
474 x 474
574 x 574
724 x 724
51
Module Size (mm)
500 x 500
600 x 600
750 x 750
16
system 130 grid options
SAS Alugrid-Q 15/19
Tile Size
Module Size
SAS International +44 (0) 118 929 0900 www.sasint.co.uk/system130
26
44
Tile Size (mm)
484 x 484
584 x 584
734 x 734
8
Module Size (mm)
500 x 500
600 x 600
750 x 750
Tile Size
Module Size
15
SAS Alugrid-P 15/16
51
Tile Size (mm)
484 x 484
584 x 584
734 x 734
16
Module Size (mm)
500 x 500
600 x 600
750 x 750
15
Tile Size
Module Size
SAS Alugrid-P Cleanseal
51
Tile Size (mm)
484 x 484
584 x 584
734 x 734
16
Module Size (mm)
500 x 500
600 x 600
750 x 750
Tile Size
Module Size
15
SAS Tee Grid T15
45
Tile Size (mm)
484 x 484
584 x 584
734 x 734
8 / 16
Module Size (mm)
500 x 500
600 x 600
750 x 750
15
Tile Size
Module Size
SAS Tee Grid T24
52
Tile Size (mm)
474 x 474
575 x 575
724 x 724
8 / 16
Module Size (mm)
500 x 500
600 x 600
750 x 750
Tile Size
Module Size
SAS International +44 (0) 118 929 0900 www.sasint.co.uk/system130
24
system 130 grid options
SAS Alugrid-P 15/08
Alugrid-Q Composition and Integration
The Alugrid-Q cross tee comprises of a steel carrier for
retention of structural integrity in fire conditions.
The aluminium thread form profile features a continuous
lineal recess with an M6 thread form and a negative
quirk rebate. This facilitates the hanging of signs and
other lightweight fixtures by means of an M6 bolt.
Alugrid-Q Junction Detail
The aluminium cross tee extrusions are machined to
create precise mitred “bird’s mouth” intersections on
the grid face.
Alugrid-Q sections can be supplied with “bird’s mouth”
mitres on one side only to fit a flush abutment to
luminaires, air grilles and other services which rest
directly on the grid but are of a larger modular size than
the ceiling tiles.
The continuous linear thread form allows the easy
location and relocation of partition heads by means of
an M6 bolt, without causing damage to the ceiling.
system 130 features
Partition Head Fixing Detail
SAS International +44 (0) 118 929 0900 www.sasint.co.uk/system130
5
8
1200 / 1500mm*
4
6
3
7
1
300mm
max
9
2
1] Emac Hanger
2] Emac Hanger Bracket
6] Perimeter Trim 7] Perimeter Wedge
3] Main Runner
8] Corner Splice
4] Double Module Cross Tee
9] System 130 Tile
5] Single Module Cross Tee
Refer to components section page 146 for full description and item numbers.
Configuration Guide
500x500mm Module
Notes
Hangers installed at 1500mm centres should be
considered for lightweight* installations only. SAS Emac
hangers must be used in conjunction with Emac hanger
brackets for installation at 1500mm centres.
Emac hangers should be installed a maximum of 300mm
from the edge of the system. Where two main runners
are clipped together, an Emac hanger should be installed
within 300mm.
It is considered good practice to stagger joints in
supporting structures.
3
4
5
600x600mm Module
Additional Loads
A lightweight* system can support additional loads
such as services up to a limit of 3kg. This limit is based
on a point or uniformly distributed load over 0.36m²,
positioned a minimum of 1000mm apart. This should be
considered for lightweight* installations only.
*“Lightweight” meaning base system only such as fleece
or pad tile backing. Where a ceiling supports the load
of services or for acoustically upgraded systems, Emac
hanger centres should be installed at 1200mm centres.
Hanger centres should always be considered when
applying additional loads.
For further advice please contact the SAS technical
department.
3
4
5
750x750mm Module
3
5
SAS International +44 (0) 118 929 0900 www.sasint.co.uk/installation
system 130 installation advice
300mm
max
5
1
system 130 installation advice, alugrid-q
3
2
4
1] Alugrid-Q Main Runner 2] Alugrid Main Runner (bird’s mouths one side) 3] Double Module Cross Tee
5] Single Module Oversailing Cross Tee
4] Single Module Cross Tee
1]
2]
3]
4]
5]
Optional Double Module
Oversailing Cross Tee
System 130 Alugrid-Q main runner (1) is supplied as
standard with bird’s mouths both sides to suit module
sizes. Alugrid-Q main runner can be supplied with bird’s
mouths one side for individual project requirements
(2).
Alugrid-Q Cross Tees are supplied as standard with
arrowhead detail each end (4). Double modules cross
tees are additionally supplied with a bird’s mouth detail
both sides (3).
Alugird Cross Tees, both single and double module, can
be supplied as “oversailing” cross tees (5). Oversailing
Cross Tees have a longer tee runner enabling full tiles to
be used at the perimeter. The Oversailing Cross Tees are
integrated and supported by a range of SAS perimeter
trims.
Oversailing Cross Tee and Perimeter detail
SAS International +44 (0) 118 929 0900 www.sasint.co.uk/installation
SAS International, 31 Suttons Business Park, London Road, Reading, Berkshire RG6 1AZ, United Kingdom
Tel: +44 (0)118 929 0900 Fax: +44 (0)118 929 0901 www.sasint.co.uk
SAS International, Unit 228 Block C, Blanchardstown Corporate Park, Dublin 15, Ireland
Tel: +353 (0) 1899 1134 Fax: +353 (0) 1899 1753
All Information and details in this brochure are correct at time of going to press. Published by SAS International. All rights reserved. Copyright © 2008
Printed using vegetable based inks on FSC certified paper. The printer holds the environmental standard IS0 14001