metal ceilings system 130 modular lay-in tiles (exposed grid) SAS International +44 (0) 118 929 0900 www.sasint.co.uk System Description SAS System 130 is a range of lay-in tiles supported from SAS Alugrid or SAS Tee Grid. Alugrid-Q features a continuous linear recess with an M6 thread and negative quirk relief detail abutting the ceiling tiles, giving a completely flush ceiling. Alugrid-P is a plain version without the threaded recess and gives a completely flush ceiling. Tee Grid is a butt cut exposed grid that provides a tegular effect. System Features • Easy access to the ceiling void • Minimum 25-year product life expectancy System Features with SAS Alugrid • Shadow line feature between grid and tile • Precise mitred joints • Continuous linear thread form • Clean flush ceiling plane System Features with SAS Tee Grid • Strong modular appearance • Butt cut junctions eliminating corner shadows Access Tiles can be lifted out of the ceiling system to gain access to the ceiling void. Standard Module Sizes (mm) 500 x 500 600 x 600 750 x 750 system 130 information Special sizes are available on request. Please contact our technical department for further details. 300 x 300mm tiles can be supplied for use with SAS Tee Grid or tartan grid configurations. Finish Polyester Powder coated supplied as standard with a RAL 9010 smooth finish; a fine textured finish (SAS FT), anti-bacterial coating (SAS AB) and other colours are available. See page 36 for a full range of paint finish options. Grid System Lay-in SAS Alugrid-Q, SAS Alugrid-P, SAS Alugrid Cleanseal, SAS Tee Grid, see page 146 for components. Shape Tiles are square with out-turned flanges laid onto the exposed grid system. Perforation Typically supplied with 1522, 1820 or 2516 perforation. See page 103 for full details and perforation options. Integration Apertures can be formed during manufacturing for luminaires and other services, see pages 38–39 for further details. Weight Approximately 5kg/m² for 8mm steel tiles, acoustic/ insulation pad and SAS Tee Grid. Approximately 7.5kg/m² for 16mm steel tiles, acoustic pad and SAS Alugrid suspension. SAS International +44 (0) 118 929 0900 www.sasint.co.uk/system130 5 8 1200 / 1500mm* 4 6 3 7 1 300mm max 9 2 1] Emac Hanger 2] Emac Hanger Bracket 6] Perimeter Trim 7] Perimeter Wedge 3] Main Runner 8] Corner Splice 4] Double Module Cross Tee 9] System 130 Tile 5] Single Module Cross Tee *Lightweight installations only, see page 161 for full details. Emac suspension components can be found on page 144, System 130 / SAS Tee Grid / Alugrid component details can be found on page 146. Perimeter trims and accessories can be found on page 115. 44 / 51mm Section Drawing 4/5 9 Acoustic Performance Data Attenuation Absorption Class NRC αω dB 8mm, 16mm, 19mm plain tile. 43 8mm, 16mm, 19mm perforated tile with acoustic fleece. 13 8mm perforated tile with 8mm x 80kg/m³ acoustic pad, factory sealed. 21 16mm perforated tile with 16mm x 80kg/m³ acoustic pad, factory sealed. 27 16mm perforated tile with 16mm x 80kg/m³ acoustic pad and steel backing plate. 41 19mm perforated tile with 19mm x 80kg/m³ acoustic pad, factory sealed. 30 19mm perforated tile with 6mm x 80kg/m³ acoustic pad and 12.5mm plasterboard. 45 N/A Class C 0.70 0.65 Class C 0.80 0.75 Class B 0.85 0.85 Class D 0.65 0.50 Class A 0.85 0.90 Class D 0.65 0.55 Results above extracted from tests undertaken using perforation reference S1820. SAS International +44 (0) 118 929 0900 www.sasint.co.uk/system130 system 130 technical 300mm max SAS Alugrid-Q 15/08 44 Tile Size (mm) 484 x 484 584 x 584 734 x 734 8 Module Size (mm) 500 x 500 600 x 600 750 x 750 15 Tile Size Module Size SAS Alugrid-Q 15/16 51 Tile Size (mm) 484 x 484 584 x 584 734 x 734 16 Module Size (mm) 500 x 500 600 x 600 750 x 750 15 Tile Size Module Size 51 Tile Size (mm) 484 x 484 584 x 584 734 x 734 19 Module Size (mm) 500 x 500 600 x 600 750 x 750 15 Tile Size Module Size SAS Alugrid-Q 25/16 Tile Size (mm) 474 x 474 574 x 574 724 x 724 51 Module Size (mm) 500 x 500 600 x 600 750 x 750 16 system 130 grid options SAS Alugrid-Q 15/19 Tile Size Module Size SAS International +44 (0) 118 929 0900 www.sasint.co.uk/system130 26 44 Tile Size (mm) 484 x 484 584 x 584 734 x 734 8 Module Size (mm) 500 x 500 600 x 600 750 x 750 Tile Size Module Size 15 SAS Alugrid-P 15/16 51 Tile Size (mm) 484 x 484 584 x 584 734 x 734 16 Module Size (mm) 500 x 500 600 x 600 750 x 750 15 Tile Size Module Size SAS Alugrid-P Cleanseal 51 Tile Size (mm) 484 x 484 584 x 584 734 x 734 16 Module Size (mm) 500 x 500 600 x 600 750 x 750 Tile Size Module Size 15 SAS Tee Grid T15 45 Tile Size (mm) 484 x 484 584 x 584 734 x 734 8 / 16 Module Size (mm) 500 x 500 600 x 600 750 x 750 15 Tile Size Module Size SAS Tee Grid T24 52 Tile Size (mm) 474 x 474 575 x 575 724 x 724 8 / 16 Module Size (mm) 500 x 500 600 x 600 750 x 750 Tile Size Module Size SAS International +44 (0) 118 929 0900 www.sasint.co.uk/system130 24 system 130 grid options SAS Alugrid-P 15/08 Alugrid-Q Composition and Integration The Alugrid-Q cross tee comprises of a steel carrier for retention of structural integrity in fire conditions. The aluminium thread form profile features a continuous lineal recess with an M6 thread form and a negative quirk rebate. This facilitates the hanging of signs and other lightweight fixtures by means of an M6 bolt. Alugrid-Q Junction Detail The aluminium cross tee extrusions are machined to create precise mitred “bird’s mouth” intersections on the grid face. Alugrid-Q sections can be supplied with “bird’s mouth” mitres on one side only to fit a flush abutment to luminaires, air grilles and other services which rest directly on the grid but are of a larger modular size than the ceiling tiles. The continuous linear thread form allows the easy location and relocation of partition heads by means of an M6 bolt, without causing damage to the ceiling. system 130 features Partition Head Fixing Detail SAS International +44 (0) 118 929 0900 www.sasint.co.uk/system130 5 8 1200 / 1500mm* 4 6 3 7 1 300mm max 9 2 1] Emac Hanger 2] Emac Hanger Bracket 6] Perimeter Trim 7] Perimeter Wedge 3] Main Runner 8] Corner Splice 4] Double Module Cross Tee 9] System 130 Tile 5] Single Module Cross Tee Refer to components section page 146 for full description and item numbers. Configuration Guide 500x500mm Module Notes Hangers installed at 1500mm centres should be considered for lightweight* installations only. SAS Emac hangers must be used in conjunction with Emac hanger brackets for installation at 1500mm centres. Emac hangers should be installed a maximum of 300mm from the edge of the system. Where two main runners are clipped together, an Emac hanger should be installed within 300mm. It is considered good practice to stagger joints in supporting structures. 3 4 5 600x600mm Module Additional Loads A lightweight* system can support additional loads such as services up to a limit of 3kg. This limit is based on a point or uniformly distributed load over 0.36m², positioned a minimum of 1000mm apart. This should be considered for lightweight* installations only. *“Lightweight” meaning base system only such as fleece or pad tile backing. Where a ceiling supports the load of services or for acoustically upgraded systems, Emac hanger centres should be installed at 1200mm centres. Hanger centres should always be considered when applying additional loads. For further advice please contact the SAS technical department. 3 4 5 750x750mm Module 3 5 SAS International +44 (0) 118 929 0900 www.sasint.co.uk/installation system 130 installation advice 300mm max 5 1 system 130 installation advice, alugrid-q 3 2 4 1] Alugrid-Q Main Runner 2] Alugrid Main Runner (bird’s mouths one side) 3] Double Module Cross Tee 5] Single Module Oversailing Cross Tee 4] Single Module Cross Tee 1] 2] 3] 4] 5] Optional Double Module Oversailing Cross Tee System 130 Alugrid-Q main runner (1) is supplied as standard with bird’s mouths both sides to suit module sizes. Alugrid-Q main runner can be supplied with bird’s mouths one side for individual project requirements (2). Alugrid-Q Cross Tees are supplied as standard with arrowhead detail each end (4). Double modules cross tees are additionally supplied with a bird’s mouth detail both sides (3). Alugird Cross Tees, both single and double module, can be supplied as “oversailing” cross tees (5). Oversailing Cross Tees have a longer tee runner enabling full tiles to be used at the perimeter. The Oversailing Cross Tees are integrated and supported by a range of SAS perimeter trims. Oversailing Cross Tee and Perimeter detail SAS International +44 (0) 118 929 0900 www.sasint.co.uk/installation SAS International, 31 Suttons Business Park, London Road, Reading, Berkshire RG6 1AZ, United Kingdom Tel: +44 (0)118 929 0900 Fax: +44 (0)118 929 0901 www.sasint.co.uk SAS International, Unit 228 Block C, Blanchardstown Corporate Park, Dublin 15, Ireland Tel: +353 (0) 1899 1134 Fax: +353 (0) 1899 1753 All Information and details in this brochure are correct at time of going to press. Published by SAS International. All rights reserved. Copyright © 2008 Printed using vegetable based inks on FSC certified paper. The printer holds the environmental standard IS0 14001