correx powered anode

advertisement
(5 3 .5 )
Xh
CORREX POWERED ANODE
B AL ANCED F L U E WAT ER H EAT ERS
E
T/ D 0 3 2
T
JUNE 2007
E
TE CH N ICAL
D ATA SH E E T
CI/SfB
H
F IT T ING AND OPERAT ING INS T RU CT IONS F OR RS C 1 5 0 AND RS C 1 9 0
a) L O W M AIN TE N AN CE CO STS (Correx is non- sac rifi c ial, therefore no anod e m aintenanc e is need ed ).
S
TH E IN TR O D U CTIO N O F TH IS K IT H AS TH R E E M AIN AD V AN TAG E S TO BE CO N SID E R E D
b ) L O W R U N N IN G CO STS – L E SS TH AN 3 5 kW H P E R Y E AR .
The m ethod of c onnec tion to the m ains elec tric ity su p p ly shou ld fac ilitate c om p lete elec tric al isolation of the
ap p lianc e p referab ly b y u se of an u nsw itc hed shu ttered soc ket ou tlet in c onju nc tion w ith a fu sed three p in p lu g
b oth c om p ly ing w ith req u irem ents of BS 1 3 6 3 /A.
T
This kit is d esig ned to ru n off 2 2 0 /2 4 0 V 1 p h 5 0 H z p erm anent su p p ly and the fu se rating is 3 Am p .
A
W iring ex ternal to the w ater heater m u st b e installed in ac c ord anc e w ith the I.E .E . R eg u lations for the w iring of
b u ild ing s and to any loc al reg u lations that m ay ap p ly .
A
c ) BE TTE R P R O TE CTIO N P AR TICU L AR L Y IN AR E AS O F L O W E L E CTR ICAL CO N D U CTIV ITY .
2.
R em ov e ex isting hot ou tlet nip p le/anod e.
3.
F it rep lac em ent c orrex anod e u sing nip p le and tee (fi tting s p rov id ed ). See F ig . 1 .
4.
F ix p otentiostat to heater c asing , u sing retaining b rac ket, ad jac ent to c orrex anod e.
5.
Connec t ou tp u t lead (sp ad e c onnec tor) onto anod e c onnec tion.
6.
R em ov e one heater top c ov er retaining self tap p ing sc rew and c onnec t ring term inal at this p oint (earth
retu rn).
6.
Connec t p otentiostat m ains inp u t c ab le to a p erm anent 2 4 0 V elec tric al su p p ly v ia an u nsw itc hed
sp u r ou tlet (fu se rating 3 Am p s).
B.
Test the installation
1.
R efi ll the w ater heater and c hec k for leaks.
2.
Sw itc h on elec tric al su p p ly to c orrex p ow ered anod e.
3.
The g reen c ontrol lam p on the p otentiostat ind ic ates that the installation is fu nc tioning c orrec tly .
4.
The red c ontrol lam p on the p otentiostat ind ic ates a fau lt. Sw itc h off elec tric al su p p ly b efore any
rep air w ork is c arried ou t.
L
D rain d ow n w ater heater.
A
1.
C
To install the kit
C
E
T
The installation is now c om p lete.
H
N
A.
I
The p oint of c onnec tion to the m ains shou ld b e read ily ac c essib le and ad jac ent to the ap p lianc e.
D
Alternativ ely a fu sed d ou b le p ole sw itc h or fu sed sp u r b ox serv ing only the heater m ay b e u sed .
FIG. 1
Output lead anode
connection
3
/4" Nipple
3
/4" BSP Tee
Earth return
connecton
Cold feed inlet
Potentiostat
240V
permanent
supply
Correx anode
replaces hot
outlet
nipple/anode
MODEL
HOT OUTLET
NIPPLE/ANODE
NO. CORREX
ANODES/SIZE
RSC 150
1
1 x 800mm
RSC 190
1
1 x 800mm
Powered anode fittings pack – Part No. B196
1 – Correx Powered Anode
1 – Potentiostat
1 – Envelope containing fixing clamps/clips
To include the following
1 – 3/4" BSP brass square tee (C883)
1 – 3/4" Galvanised Plasti-Cert lined nipple (C247 )
Since it is our policy to strive for progressive design and performance
all our equipment is subject to alteration without notice.
Andrews Water Heaters
Wood Lane, Erdington
Birmingham B24 9Q P
Telephone: 0845 07 0 1058 Fax: 0845 07 0 1059