(5 3 .5 ) Xh CORREX POWERED ANODE B AL ANCED F L U E WAT ER H EAT ERS E T/ D 0 3 2 T JUNE 2007 E TE CH N ICAL D ATA SH E E T CI/SfB H F IT T ING AND OPERAT ING INS T RU CT IONS F OR RS C 1 5 0 AND RS C 1 9 0 a) L O W M AIN TE N AN CE CO STS (Correx is non- sac rifi c ial, therefore no anod e m aintenanc e is need ed ). S TH E IN TR O D U CTIO N O F TH IS K IT H AS TH R E E M AIN AD V AN TAG E S TO BE CO N SID E R E D b ) L O W R U N N IN G CO STS – L E SS TH AN 3 5 kW H P E R Y E AR . The m ethod of c onnec tion to the m ains elec tric ity su p p ly shou ld fac ilitate c om p lete elec tric al isolation of the ap p lianc e p referab ly b y u se of an u nsw itc hed shu ttered soc ket ou tlet in c onju nc tion w ith a fu sed three p in p lu g b oth c om p ly ing w ith req u irem ents of BS 1 3 6 3 /A. T This kit is d esig ned to ru n off 2 2 0 /2 4 0 V 1 p h 5 0 H z p erm anent su p p ly and the fu se rating is 3 Am p . A W iring ex ternal to the w ater heater m u st b e installed in ac c ord anc e w ith the I.E .E . R eg u lations for the w iring of b u ild ing s and to any loc al reg u lations that m ay ap p ly . A c ) BE TTE R P R O TE CTIO N P AR TICU L AR L Y IN AR E AS O F L O W E L E CTR ICAL CO N D U CTIV ITY . 2. R em ov e ex isting hot ou tlet nip p le/anod e. 3. F it rep lac em ent c orrex anod e u sing nip p le and tee (fi tting s p rov id ed ). See F ig . 1 . 4. F ix p otentiostat to heater c asing , u sing retaining b rac ket, ad jac ent to c orrex anod e. 5. Connec t ou tp u t lead (sp ad e c onnec tor) onto anod e c onnec tion. 6. R em ov e one heater top c ov er retaining self tap p ing sc rew and c onnec t ring term inal at this p oint (earth retu rn). 6. Connec t p otentiostat m ains inp u t c ab le to a p erm anent 2 4 0 V elec tric al su p p ly v ia an u nsw itc hed sp u r ou tlet (fu se rating 3 Am p s). B. Test the installation 1. R efi ll the w ater heater and c hec k for leaks. 2. Sw itc h on elec tric al su p p ly to c orrex p ow ered anod e. 3. The g reen c ontrol lam p on the p otentiostat ind ic ates that the installation is fu nc tioning c orrec tly . 4. The red c ontrol lam p on the p otentiostat ind ic ates a fau lt. Sw itc h off elec tric al su p p ly b efore any rep air w ork is c arried ou t. L D rain d ow n w ater heater. A 1. C To install the kit C E T The installation is now c om p lete. H N A. I The p oint of c onnec tion to the m ains shou ld b e read ily ac c essib le and ad jac ent to the ap p lianc e. D Alternativ ely a fu sed d ou b le p ole sw itc h or fu sed sp u r b ox serv ing only the heater m ay b e u sed . FIG. 1 Output lead anode connection 3 /4" Nipple 3 /4" BSP Tee Earth return connecton Cold feed inlet Potentiostat 240V permanent supply Correx anode replaces hot outlet nipple/anode MODEL HOT OUTLET NIPPLE/ANODE NO. CORREX ANODES/SIZE RSC 150 1 1 x 800mm RSC 190 1 1 x 800mm Powered anode fittings pack – Part No. B196 1 – Correx Powered Anode 1 – Potentiostat 1 – Envelope containing fixing clamps/clips To include the following 1 – 3/4" BSP brass square tee (C883) 1 – 3/4" Galvanised Plasti-Cert lined nipple (C247 ) Since it is our policy to strive for progressive design and performance all our equipment is subject to alteration without notice. Andrews Water Heaters Wood Lane, Erdington Birmingham B24 9Q P Telephone: 0845 07 0 1058 Fax: 0845 07 0 1059