KTS Supply air valve KTS Supply air valve KTS valve is a supply air valve for ceiling mounting in offices, houses etc. Quick Selection (50Pa) Size KTS-100-C KTS-100-C KTS-125-C KTS-125-C KTS-160-C KTS-160-C with sector plate without sector plate with sector plate without sector plate with sector plate without sector plate Fläkt Woods 4890GB 2014.12 Air flow range l/s [m3/h] at sound level 25 dB 30 dB 35 dB 15 22 [79] 19 29 [104] 20 28 [101] 25 42 [151] 20 42 [151] 40 66 [238] - 1 Product Facts • CleanVent coating as standard • Manufactured of steel • Equipped with a sector plate for direction of the air flow Product code example Supply air valve KTS-100-C Specifications are subject to alteration without further notice. KTS Supply air valve Selection diagrams KTS-100-C with sector plate KTS-100-C without sector plate KTS-125-C with sector plate KTS-125-C without sector plate KTS-160-C with sector plate KTS-160-C without sector plate Fläkt Woods 4890GB 2014.12 2 Specifications are subject to alteration without further notice. KTS Supply air valve Acoustical data, dimensions and weight Sound power level Lw Throw in free space mounting KTS with sector plate In case of free space mounting the throw can be calculated by using the following factors: when Δt = 0°C: 125 2 3 7 3 Correction of sound level in dB at octave bands, middle frequency, Hz 250 500 1000 2000 4000 2 0 -2 -4 -4 3 3 0 -8 -15 4 2 -1 -6 -17 2 2 2 2 2 Adjustment s(mm) 4 9 15 8000 -12 -29 -31 3 Dimensions and weight KTS without sector plate 8000 -11 -29 -32 3 C 125 -2 4 7 3 Correction of sound level in dB at octave bands, middle frequency, Hz 250 500 1000 2000 4000 2 1 -1 -4 -5 5 3 -1 -11 -17 6 3 -2 -11 -19 2 2 2 2 2 B KTS 100 125 160 Tol.+/- factor 0.5 0.45 0.4 s(m m ) KTS 100 125 160 Tol.+/- Sound power levels by octave bands are obtained by adding to total sound pressure level Lp10A, dB(A), the corrections Koct presented in the table according to the following formula: ØD LWoct = Lp10A + Koct Size 100 125 160 Correction Koct is average value in range of use of KTS unit. ØD [mm] 143 173 216 B [mm] 67 76 80 C [mm] 17 18 19 Weight [kg] 0,27 0,43 0,58 Sound attenuation ΔL KKT 4000 7 6 6 2 8000 8 5 6 3 KKL ØD Correction of sound level in dB at 250 500 1000 2000 13 11 9 8 11 9 9 7 10 9 9 7 2 2 2 2 Ød 125 18 16 14 3 ØD 63 22 20 18 6 Ød KTS 100 125 160 Tol.+/- The average sound attenuation ΔL from duct to room including the orifice attenuation of the connecting duct in ceiling installation, is obtained in the table above. 50 50 Diffusion pattern KTS without sector plate Size 100 125 160 KTS with sector plate Pack size 56 36 25 KR Ød [mm] 99 124 159 ØD [mm] 122 148 184 Weight KKT Weight KKL [g] [g] 75 71 102 97 131 125 SL 7, 5 316 Regulation Δt(C°) b h k 1.45xL0.2 0.04xL0.2 1.0 0.8 1.45xL0.2 0.04xL0.2 1.0 0.75 s=4 s=4 0 -10 1.45xL0.2(Δt)0.08xL0.2(Δt) s=15 s=15 0 -10 1.45xL0.2(Δt)0.1xL0.2(Δt) Ød KR 100 125 160 ØD [mm] 150 180 223 SL 100 125 160 Fläkt Woods 4890GB 2014.12 3 Ød [mm] 100 125 160 Ød [mm] 102 130 160 Specifications are subject to alteration without further notice. KTS Supply air valve Construction, material, product code Construction Descriptive text KTS valve is a supply air valve for ceiling mounting in offices, houses etc. The body is equipped with cellular plastic gasket to form an airtight seal with the mounting ring. The valve is equipped with a sector plate for direction of the air flow. Adjustment of the valve or sector plate is achieved by simply rotating the disc and/or sector plate to the desired setting and secured by means of a single lock nut. Supply air valve KTS, e.g. KTS-160-C manufactured by Fläkt Woods. The KTS is manufactured from sheet steel and stove enamelled in white. Other colours are available to special order. CleanVent coating as standard. Product code Supply air valve KTS-aaa-b Supply air valve with springs KTSJ-aaa-b Size (aaa) 100, 125, 160 Mounting rings KKL and KKT are manufactured from galvanized steel sheet. KKT is equipped with rubber sealing gasket. Surface finish (b) C = Standard CleanVent coating E = Special colour Installation Accessories Mounting ring KKL or KKT is fitted into the duct with screws or rivets. The valve is fitted into the mounting ring by a “screwing action” to locate lugs into indents in the mounting ring. The valve can also be fitted with springs (model KTSJ) and the mounting ring is not needed. Mounting ring with rubber gasket KKT-aaa Measurement and regulation of air flow Mounting ring without rubber gasket KKL-aaa Size (aaa) 100, 125, 160 Protection plate SL-aaa The measurement of air flow is made by a pressure difference measurement with a separate measuring tube. Air flow can be adjusted by changing the adjustments by rotating the disc. Extension collar KR-aaa Accessories In order to protect the ceiling an extra protection plate SL and extension collar KR are available, both made of sheet steel and stove enamelled white. The protection plate is fitted between the air valve and the ceiling. Size (aaa) 100, 125, 160 Spare parts Seal COGZ-aaa-2 Size (aaa) 100,125,160 Fläkt Woods 4890GB 2014.12 4 Specifications are subject to alteration without further notice.