Series eD | Avantgarde.Line with natural convection Series fD

advertisement
Avantgard.Line | Series ED, FD
Series ED | Avantgarde.Line with natural convection
Standard features
•
•
•
•
Controller with LCD display
Electromechanical control of the exhaust air flap
2 chrome-plated racks
Class 2 integrated independent adjustable temperature
safety device (DIN 12880) with visual alarm
• USB port
ED 56
Technical data of the Series ED
Description
ED 56
ED 115
ED 260
Interior volume [L]
57
114
255
Housing dimensions not incl. fittings and connections
W x H x D [mm]
560 x 625 x 565
710 x 735 x 605
810 x 965 x 760
Temperature range 15 °C above ambient temperature to [°C]
300
—
—
Temperature range 8 °C above ambient temperature to [°C]
—
300
300
Basic data
Performance Data Temperature
Temperature uniformity at 150 °C [± K]
2,5
2
-
Temperature fluctuation at 50 °C [± K]
0,4
0,4
-
Heating-up time to 150 °C [min]
45
60
-
Recovery time after 30 seconds door open at 150 °C [min]
25
20
-
Energy consumption at 150 °C [Wh/h]
180
250
-
Series FD | Avantgarde.Line with forced convection
Standard features
•
•
•
•
Controller with LCD display
Electromechanical control of the exhaust air flap
2 chrome-plated racks
Class 2 integrated independent adjustable temperature
safety device (DIN 12880) with visual alarm
• USB port
FD 56
6
Series FED | Avantgard.Line
Technical data of the Series FD
Description
FD 56
FD 115
FD 260
Interior volume [L]
60
116
259
Housing dimensions not incl. fittings and connections
W x H x D [mm]
560 x 625 x 565
710 x 735 x 605
810 x 965 x 760
Temperature range 15 °C above ambient temperature to [°C]
300
300
300
Temperature uniformity at 150 °C [± K]
1,7
1,7
-
Temperature fluctuation at 150 °C [± K]
0,3
0,3
-
Heating-up time to 150 °C [min]
15
20
-
Recovery time after 30 seconds door open at 150 °C [min]
5
5
-
Energy consumption at 150 °C [Wh/h]
290
340
-
Basic data
Performance Data Temperature
Series FED | Avantgarde.Line with forced convection
and enhanced timer functions
Standard features
•
•
•
•
•
Adjustable fan speed
Controller with LCD display with enhanced timer functions
Electromechanical control of the exhaust air flap
2 chrome-plated racks
Class 2 integrated independent adjustable temperature
safety device (DIN 12880) with visual alarm
• Ethernet interface
• USB port
FED 260
Technical data of the Series FED
Description
FED 56
FED 115
FED 260
Interior volume [L]
60
116
259
Housing dimensions not incl. fittings and connections
W x H x D [mm]
560 x 625 x 565
710 x 735 x 605
810 x 965 x 760
Temperature range 10 °C above ambient temperature to [°C]
300
300
300
Temperature uniformity at 150 °C [± K]
1,4
1,2
-
Temperature fluctuation at 150 °C [± K]
0,3
0,3
-
Heating-up time to 150 °C [min]
15
20
-
Recovery time after 30 seconds door open at 150 °C [min]
5
5
-
Energy consumption at 150 °C [Wh/h]
290
340
-
Basic data
Performance Data Temperature
7
Classic.Line | Drying and heating chambers
Get ahead with BINDER technology
Uniform drying conditions regardless of the sample size and
number of samples thanks to BINDER APT.line™ preheating
chamber technology.
Convenient work environment thanks to the BINDER inner chamber concept: rack with tilt protection, no permanent fixtures,
stainless-steel inner chamber.
Wide range of applications thanks to wide temperature range up
to 300 °C. The FP and M series also impress with their adjustable air change rates and large power reserves.
Individual programming via LCD screen controller with comprehensive program functions. The process parameters can be
displayed differently. (M series)
9
Classic.Line | Series ED, FD
Series ED | Classic.Line with natural convection
Standard features
•
•
•
•
Adjustable exhaust air flap
Controller with timer functions
2 chrome-plated racks
Class 2 independent adjustable temperature
safety device (DIN 12880) with visual alarm
ED 400
Technical data of the Series ED
Description
ED 23
ED 400
ED 720
Interior volume [L]
20
400
720
Housing dimensions not incl. fittings and connections
W x H x D [mm]
435 x 495 x 520
1.235 x 1.025 x 765
1.235 x 1.530 x 865
Temperature range 5 °C above ambient temperature to [°C]
300
300
300
Temperature uniformity at 150 °C [± K]
2,8
3
3,6
Temperature fluctuation at 150 °C [± K]
0,5
0,5
0,5
Heating-up time to 150 °C [min]
28
71
84
Recovery time after 30 seconds door open at 150 °C [min]
28
31
34
Basic data
Performance Data Temperature
Series FD | Classic.Line with forced convection
Standard features
•
•
•
•
FD 23
10
Adjustable exhaust air flap
Controller with timer functions
2 chrome-plated racks
Class 2 independent adjustable temperature safety device (DIN
12880) with visual alarm
Series FED | Classic.Line
Technical data of the Series FD
Description
FD 23
Basic data
Interior volume [L]
20
Housing dimensions not incl. fittings and connections
W x H x D [mm]
435 x 495 x 520
Performance Data Temperature
Temperature range 5 °C above ambient temperature to [°C]
300
Temperature uniformity at 150 °C [± K]
2,5
Temperature fluctuation at 150 °C [± K]
0,3
Heating-up time to 150 °C [min]
25
Recovery time after 30 seconds door open at 150 °C [min]
6
Series FED | Classic.Line with forced convection
and enhanced timer functions
Standard features
•
•
•
•
•
Adjustable fan speed
Adjustable exhaust air flap
Controller with expanded timer functions
2 chrome-plated racks
Class 2 independent adjustable temperature safety device
(DIN 12880) with visual alarm
• Computer interface: RS 422
FED 720
Technical data of the Series FED
Description
FED 400
FED 720
Interior volume [L]
400
720
Housing dimensions not incl. fittings and connections
W x H x D [mm]
1.235 x 1.025 x 765
1.235 x 1.530 x 865
Temperature range 5 °C above ambient temperature to [°C]
300
300
Temperature uniformity at 150 °C [± K]
3,8
3
Temperature fluctuation at 150 °C [± K]
0,7
0,3
Heating-up time to 150 °C [min]
29
29
Recovery time after 30 seconds door open at 150 °C [min]
6
8
Basic data
Performance Data Temperature
11
Wolf Laboratories Limited
www.wolflabs.co.uk
Tel: 01759 301142
Fax:01759 301143
sales@wolflabs.co.uk
Use the above details to contact us if this literature doesn't answer all your
questions.
Pricing on any accessories shown can be found by keying the part number
into the search box on our website.