Sealed Weather-Proof Construction Smaller Lighter More Powerful Made in USA Rev B 005-0006128 Uninterruptible Power Supply Military-Grade UPS Uninterruptible Power Supply SynQor’s UPS is designed for the extreme environmental and demanding electrical conditions of Military/Avionics applications. SynQor’s UPS incorporates field proven high efficiency designs and rugged packaging technologies. This UPS will accept a wide range of input voltage and frequency values while delivering a well-conditioned AC output to the load. Its use of lithium polymer batteries permits the lowest profile and lowest weight solution in its power class. It is designed and manufactured to comply with a wide range of military standards. Options include a DC output and the ability to also draw power from a military standard 28VDC input. UPS Product Features Options Sealed, weather-proof, shock-proof construction Military Tough, Die-Cast Aluminum Chassis 1250W-1500VA; 2500W-3000VA output power >10 minute run-time at full power Full power operation -20°C to +55°C (Storage: -20°C to +65°C) True on-line double conversion Hot swappable internal battery pack (lithium polymer) Universal AC input: 80-265VAC; 47-65Hz Dual input: AC and optional DC Cold-start with no AC or DC input connections Power factor correction at AC input Pure sinusoidal AC output voltage (115VAC, 60Hz) Handles 0.0—1.0 power factor loads and non-linear loads User I/O and Configuration signal ports Up to 3 units can be combined for higher power, voltage or a 3-phase AC output 1U high rack mount unit (17” x 21.6”) UPS-1500 2U high rack mount unit (17” x 21.6”) UPS-1500 2U high rack mount unit (17” x 22.2”) UPS-3000 Low weight: 32 lbs. (UPS-1500 1U including battery) Low weight: 50 lbs. (UPS-1500 2U including battery) Low weight: 65 lbs. (UPS-3000 including batteries) DC input (28Vnom) for dual source 2U Extended battery pack gives >24 minutes of run-time (UPS-1500) Wide-range AC input frequency: 47Hz to 800Hz 115Vrms or 230Vrms AC output 50Hz, 60Hz, or 400Hz output DC1: Auxiliary isolated DC output (up to 500W) DC2: High power DC output parallelable for higher power (UPS‑1500 up to 1250W; UPS‑3000 up to 2500W) Total AC & DC1 & DC2 output power UPS‑1500 = 1250W Total AC & DC1 & DC2 output power UPS‑3000 = 2500W Shipboard version with floating neutral wire Rack mounting style Specification Compliance UPS units are designed to meet: MIL-STD-704 - Aircraft Electrical Power Mil-STD-1399-300 - Interface Shipboard MIL-STD-1275 - Vehicle Electrical Power MIL-STD-461 - Electromagnetic Interference MIL-STD-810 - Environmental Engineering block diagram AC INPUT DC INPUT or DC2 OUTPUT AC to DC w/ PFC and ISOLATION ISOLATED INVERTER AC OUTPUT ELECTRONIC SWITCH / Non-Isolated DC-DC Converter ISOLATED DC/DC CONVERTER DC OUTPUT (OPTIONAL) (OPTIONAL) BATTERY with CHARGER and ELECTRONIC SWITCH BULK ENERGY STORAGE CAPACITOR 1.25kW 1U Model SynQor Headquarters 155 Swanson Road, Boxborough, MA 01719-1316 USA | 1.888.567.9596 (USA only) | www.synqor.com TECHNICAL INPUT CHARACTERISTICS ELECTRICAL CHARACTERISTICS UPS-1500 / UPS-3000 ENVIRONMENTAL CHARACTERISTICS MIL-STD-810G Voltage 80-265Vrms* Temperature Methods 501.5, 502.5 Frequency 47-65Hz Operating Temperature -20°C — +55°C (47-800Hz Optional) Storage Temperature -20°C — +65°C >0.98 at 47-65Hz Altitude Method 500.5 >0.97 at 400Hz Operating >0.93 at 800Hz Non-operating Maximum Input Current Continuous 20A / 40A (full load, 85Vrms) Electromagnetic Capability AC Input Circuit Breaker Rating 25A / 50A Operating AC Input Input Power Factor MTBF 100kHrs MIL-217F Ground Benign, Ta=25°C 0 - 15,000 ft 0 - 40,000 ft MIL-STD-461F CE101 30 Hz - 10 kHz (* Power Derating to 80% below 90Vrms) CE102 10 kHz - 10 MHz Operating DC Input (Optional) CS101 30 Hz - 150 kHz Voltage 22-33V CS106 10 kHz - 40 GHz Continuous Maximum Input Current 62A / 124A (full load, 22V) CS114 10 kHz - 200 MHz Transient Maximum Input Current 75A / 150A CS116 10 kHz - 100 MHz OUTPUT CHARACTERISTICS UPS-1500 / UPS-3000 RE101 30 Hz - 100 kHz Total Output Power Continuous 1250W / 2500W RE102 10 kHz - 18 GHz (1500VA) / (3000VA) RS101 30 Hz - 100 kHz Maximum DC1 Output Power 510W / 2 x 510W RS103 2 MHz - 40 GHz Maximum DC2 Output Power 1250W / 2500W Environmental Tests (Note: Available AC power is reduced by power delivered to the DC output) Shock/Drop Method 516.6, Procedures 1,4,6 AC Output Vibration Method 514.6, CAT 5, 7, 8, 9, 24 AC Output Waveform Pure Sinusoidal Fungus Voltage 115Vrms ± 3% Salt Fog 230Vrms ± 3% Sand and Dust 60Hz ± 0.5% Rain Method 506.5 50Hz ± 0.5% EMI MIL-STD-461F 400Hz ± 0.5% Humidity Method 507.5 26A / 52A (115Vrms) Mechanical Vibrations of 13A / 26A (230Vrms) Shipboard Equipment Load Power Factor 0-1.0 (leading or lagging) MECHANICAL CHARACTERISTICS Total Harmonic Distortion 2% UPS-1500-S-1U (1000W / 3000W resistive load) Chassis Size (H x W x D) Frequency Peak Load Current Case Material DC1 Output (optional) Method 508.6 Method 509.5 Method 510.5, Procedures 1,2 Method 528 1.73"(1U) x 17" x 21.6" Aluminum Voltage Regulation ± 3% (Over Load & Temperature) Total Weight Common Voltage / Power combinations 12V at 42A =504W (Other Options Available) 15V at 34A =510W (UPS-3000 has two separate DC1 outputs) 24V at 21A =504W 28V at 18A =504W 40V at 12.5A =500W 50V at 10A =500W UPS-1500-E-2U Chassis Size (H x W x D) 3.33"(2U) x 17" x 21.6" Case Material Aluminum Total Weight 50 lbs. (with chassis & battery) UPS-3000-S-2U Chassis Size (H x W x D) 3.40”(2U) x 17” x 22.2” Case Material Aluminum Total Weight 65 lbs. (with chassis & battery) Connectors UPS-1500 / UPS-3000 AC Input Connector MS3470L14-4P / CA02COME22-2PB DC Input Connector MS3470L18-8P / CA02COME24-10PB AC Output Connector MS3470L14-4S / CA02COME22-2SB DC1 Output Connector MS3470L14-4SW / CA02COME22-22SB DC2 Output Connector MS3470L18-8S / NA User I/O Ports HD DB15 Female Configuration I/O Port HD DB15 Male Cooling Exhaust Fans Sound Pressure Level (SPL) 54 dB(A) Air Flow 0.67(m3/min) 23.7 CFM Two / four fans in system, above specs are for each fan separately. DC2 Output (optional) Voltage Setpoint No Sharing (UPS-1500 Only) Voltage Regulation Common Voltage / Power combinations Droop Share ± 3% -2% (Over Load & Temperature) 24V at 50A =1200W 28V at 44.6A =1250W (Output droops vs. load to allow passive sharing among modules.) 24V Option Voltage Regulation 28V Option Voltage Regulation -15% (Over Load & Temperature) 26V at 0A 22V at 50A / 100A =1100W / 2500W -13% (Over Load & Temperature) 30V at 0A 26V at 48A / 96A =1250W / 2500W Designed and manufactured in the United States of America 32 lbs. (with chassis & battery) Military-Grade Uninterruptible Power Supply Options Model Number Power Battery Run-Time @ Full Power (80% Power) UPS-1500-S-1U (1 Standard Battery) 1250W 1500VA >10 min. (>13 min.) 1U 32 lbs. • 500W DC1 1250W DC2 • UPS-1500-E-2U (1 Extended Battery) 1250W 1500VA >24 min. (>31 min.) 2U 50 lbs. • 500W DC1 1250W DC2 2500W 3000VA >10 min. (>13 min.) 2U 2 X 500W DC1 2250W DC2 tatus LEDUPS-3000-S-2U (2 Standard Batteries) Pack Height UPS Output Power Battery Size On/Off Switch Weight DC Input (28V nom) DC Output Front Panel• 65 lbs. AC Input Frequency Status Indicator Panel AC Input Floating Frequency Neutral AC Output (47-65Hz or 47-800Hz) AC AC Output AC Output Output Voltage Neutral Wire Set Point Freq AC Output Voltage (115Vrms or 230Vrms) AC Output Frequency (50Hz, 60Hz or 400Hz)) • • • • • • • • • • • DC Output Additional Options Voltage DC Input S:Not Installed D:DC Input M:DC2 Out 24VDC w/Droop Share S:Standard 1U:1.73" L:47-65Hz 1:115Vrms G:Grounded 5:50Hz P:DC2 Out 24VDC E:Extended 2U:3.40" W:47-800Hz 2:230Vrms F:Floating 6:60Hz no sharing N:No Battery 4:400Hz R:DC2 Out 28VDC w/Droop Share V:DC2 OutAC 28VDC Fan COMM/AUX Ground DC Fan no sharing Rear Panel 1500:1500VA 1250W UPS 3000:3000VA 2500W DC Output Height AC Output Exhaust Port Stud Input Exhaust Input 00:None 12:12V 15:15V 24:24V 28:28V 40:40V 50:50V 000: Standard 0CE: CE Marking E00: Ethernet / SNMP ECE: Ethernet / SNMP & CE Marking AC Circuit Breaker The DC Input is not available if a DC2 Option is selected. DC2 Options(1/4 P & V-20) are only available on the UPS-1500. For valid part numbers, refer to the website or contact your local sales representative or distributor. Part Numbering Example: UPS-1500-E-2U-L1G6D28-000, UPS-1500-S-1U-L2G5S00-000, UPS-1500-S-1U-L2G5S00-0CE Side View Top View 21.60" UNIT MOUNTING HOLES 8-32 .250 x26 1.50" Front View 17.00" 1.73" Hot swappable battery pack Status LED Status Indicator Panel UPS-1500-1U UNIT 1.73” 1U Air intakes 17.00" On/Off UPS-1500-1U UNIT with DC Input/DC1 Output Options DC1 Output Option AC Output Exhaust Fan Ethernet I/O USER Ground DC Port Port CONFIG Stud Input Option Port (1/4-20) Option Exhaust Fan AC Input AC Circuit Breaker UPS-1500-1U UNIT with DC1 Output/DC2 Output Options DC1 Output Option AC Output Status LED On/Off Exhaust Fan Status Indicator Panel Ethernet I/O USER Ground DC2 Port Port CONFIG Stud Output Option Port (1/4-20) Option Exhaust Fan AC Input AC Circuit Breaker UPS-3000-2U UNIT 3.40” 2U Air intakes 17.00" UPS-3000-2U UNIT UPS Units with DC Input / DC1 Output Options DC1 Output Option AC Output Exhaust Fans DC Input Option Ethernet Port Option AC Input User I/O Exhaust Fans CONFIG Port Ground Stud (1/4-20) UPS products are available in a variety of rack mounting and extended battery configurations. See the website for data sheets with more details. AC Circuit Breaker Military-Grade Expansion Battery Module (EBM) SynQor’s Military-Grade UPS Expansion Battery (EBM) units are designed for the extreme environmental and demanding electrical conditions of Military Land, Shipboard, & Aerospace applications. SynQor’s EBM incorporates field proven high efficiency designs and rugged packaging technologies. This EBM will accept a wide range of input voltage and frequency values while delivering a DC power source to the UPS. The use of lithium polymer batteries permits the lowest profile and lowest weight solution in its power class. It is designed and manufactured in SynQor’s USA facilities to comply with a wide range of military standards. EBM Product Features Sealed, weather-proof, shock-proof construction >45 minute run-time at full power 1250W UPS >20 minute run-time at full power 2500W UPS Integral 500W battery charger Full power operation: -20°C to +55°C Universal AC input: 80-265VAC; 47-65Hz Power factor correction at AC input Dual input (AC and DC) Cold start with no AC or DC input connections 3 units can be combined for extended run time User I/O, Ethernet and Configuration signal ports 2U high rack mount unit (17” x 22.28”) Low weight: 61 lbs. Specification Compliance EBM units are designed to meet: (pending) MIL-STD-704 - Aircraft Electrical Power Mil-STD-1399-300 - Interface Shipboard MIL-STD-1275 - Vehicle Electrical Power MIL-STD-461 - Electromagnetic Interference MIL-STD-810 - Environmental Engineering EBM-1000-2U UNIT 3.48” 2U On/Off Status Indicator Panel Air intakes 17.00" EBM-1000-2U-28-3000 Back Panel UNIT Ethernet Port DC Output Exhaust Fan DC Input User I/O CONFIG Port Ground Stud (1/4-20) Exhaust Fan UPS Model Number EBM-1000-2U (Expansion Battery Module) Family EBM Battery Run-Time @ Full Power 1250W 2500W >45 min. >20 min. 1000: 1000 Watt Hours AC Input Options Power Energy AC Circuit Breaker Height 2U: 3.40” DC Output 28: 28V DC Height Weight DC Input (28V nom) DC Output AC Input Frequency (47-65Hz or 47-800Hz) 2U 61 lbs. • 28V • Power 1500: 1500W 3000: 3000W AC Input Freq. L:47-65Hz Single Phase W:47-800Hz Single Phase Additional Options 000:Standard 0CE:CE Marking E00:Ethernet/SNMP ECE:Ethernet/SNMP & CE Marking Part Numbering Example: EBM-1000-2U-28-3000-L-000 For valid part numbers, refer to the website or contact your local sales representative or distributor.