partial radiated emissions and radiated

advertisement
ELECTRICAL TESTING
0839.01
Hermon Laboratories Ltd.
Harakevet Industrial Zone, Binyamina 30500,
Israel
Tel. +972-4-6288001
Fax. +972-4-6288277
E-mail: mail@hermonlabs.com
PARTIAL RADIATED EMISSIONS AND RADIATED
IMMUNITY TEST REPORT
ACCORDING TO: EN 300 386 V1.4.1: 2008 with manufacturer’s deviations:
Radiated immunity of 10 V/m in 80 – 1000 MHz range
FOR:
Texas Instruments (Israel) Cable
Broadband Com.
TI chip, model TLK110 48p QFP
placed on Evaluation board,
model Pc405
This report is in conformity with ISO/ IEC 17025. The "A2LA Accredited" symbol endorsement applies only to the tests and
calibrations that are listed in the scope of Hermon Laboratories accreditation. The test results relate only to the items tested.
This test report shall not be reproduced in any form except in full with the written approval of Hermon Laboratories Ltd.
Page 1 of 30
Report ID: TEXEMC_EN.23555_rev1.docx
Date of Issue: 14-Apr-13
Report ID: TEXEMC_EN.23555_rev1.docx
Date of Issue: 14-Apr-13
Table of contents
1 2 3 4 5 6 6.1 6.2 6.3 6.4 6.5 6.6 7 7.1 8 8.1 9 10 11 12 13 14 Applicant information ..................................................................................................................................................... 3 Equipment under test attributes .................................................................................................................................... 3 Manufacturer information .............................................................................................................................................. 3 Test details .................................................................................................................................................................... 3 Tests summary .............................................................................................................................................................. 4 EUT description ............................................................................................................................................................. 5 General information ....................................................................................................................................................... 5 Ports and lines .............................................................................................................................................................. 5 Support and test equipment .......................................................................................................................................... 5 Test configuration .......................................................................................................................................................... 6 Performance criteria ...................................................................................................................................................... 7 Acceptance criteria ........................................................................................................................................................ 7 Emissions tests ............................................................................................................................................................. 8 Radiated disturbance .................................................................................................................................................... 8 Immunity tests ............................................................................................................................................................. 19 Radiated immunity to radio frequency electromagnetic field ....................................................................................... 19 APPENDIX A Test equipment and ancillaries used for tests ....................................................................................... 25 APPENDIX B Measurement uncertainties................................................................................................................... 26 APPENDIX C Test laboratory description ................................................................................................................... 27 APPENDIX D Specification references ....................................................................................................................... 27 APPENDIX E Test equipment correction factors ......................................................................................................... 28 APPENDIX F Abbreviations and acronyms ................................................................................................................. 30 Page 2 of 30
Report ID: TEXEMC_EN.23555_rev1.docx
Date of Issue: 14-Apr-13
1 Applicant information
Client name:
Texas Instruments (Israel) Cable Broadband Com.
Address:
26 Zarchin Street, 43662 Raanana, Israel
Telephone:
+972 9970 6969
Fax:
+972 9970 6500
E-mail:
noam.sadan@ti.com
Contact name:
Mr. Noam Sadan
2 Equipment under test attributes
Product name:
TI chip, model TLK110 48p QFP placed on Evaluation board, model Pc405
Serial number:
51611
Hardware version:
1
Software release:
1
Receipt date
12/11/2012
3 Manufacturer information
Manufacturer name:
Texas Instruments (Israel) Cable Broadband Com.
Address:
26 Zarchin Street, 43662 Raanana, Israel
Telephone:
+972 9970 6969
Fax:
+972 9970 6500
E-Mail:
noam.sadan@ti.com
Contact name:
Mr. Noam Sadan
4 Test details
Project ID:
23555
Location:
Hermon Laboratories Ltd. Harakevet Industrial Zone, Binyamina 30500, Israel
Test started:
12/11/2012
Test completed:
12/12/2012
Test specification(s):
EN 300 386 V1.4.1: 2008 with manufacturer’s deviations:
Radiated immunity of 10 V/m in 80 – 1000 MHz range
Page 3 of 30
Report ID: TEXEMC_EN.23555_rev1.docx
Date of Issue: 14-Apr-13
5 Tests summary
Test
Status
EN 300 386 with manufacturer’s deviations
Radiated emissions, Class B
Pass preliminary test
Radiated immunity to radio frequency electromagnetic field
of 10 V/m in 80 – 1000 MHz range
Pass preliminary test
The test results relate only to the items tested.
Name and Title
Date
Tested by:
Mr. V. Dorofeyev, test engineer
December 12, 2012
Reviewed by:
Mrs. M. Cherniavsky, certification engineer
April 14, 2013
Approved by:
Mr. M. Nikishin, EMC and radio group manager
May 5, 2013
Signature
Page 4 of 30
Report ID: TEXEMC_EN.23555_rev1.docx
Date of Issue: 14-Apr-13
6
EUT description
6.1
General information
The EUT is TI chip (Ethernet device) placed on the evaluation board enclosed in a metal enclosure. The EUT is
powered from 5 VDC.
6.2
6.3
Ports and lines
Port
type
Port
description
Connected from
Connected to
Qty.
Cable type
Cable
length, m
Signal
Ethernet
EUT
External loopback
1
Shielded
2.5
Control
USB
Laptop
USB2MII Board
(FPGA Board)
1
Shielded
5
Support and test equipment
Description
Manufacturer
Model number
Serial number
Laptop
Dell
D630
E0101139-00
USB2MII Board (FPGA Board)
Texas instruments
Pc126
42662
Page 5 of 30
Report ID: TEXEMC_EN.23555_rev1.docx
Date of Issue: 14-Apr-13
6.4
Test configuration
6.4.1
EUT setup for radiation through cable
6.4.2
EUT setup for radiation from the EUT pins
Page 6 of 30
Report ID: TEXEMC_EN.23555_rev1.docx
Date of Issue: 14-Apr-13
6.5
Performance criteria
6.5.1
General performance criteria of EN 300 386, Section 10
6.5.1.1 Performance criterion A
The equipment shall continue to operate as intended. No degradation of performance or loss of function is allowed
below a performance level specified by the manufacturer when the equipment is used as intended. The
performance level may be replaced by a permissible loss of performance. If the manufacturer does not specify the
minimum performance level or the permissible performance loss, then either of these may be derived from the
product description and documentation, and by what the user may reasonably expect from the equipment if used as
intended.
6.5.2
Specific performance criteria of EN 300 386, Section 11 (Switching equipment specific requirements)
6.5.2.1 11.3.1 Digital ports
Performance criterion A:
During the sweep:
the established connections shall be maintained throughout testing and the transfer of information shall be
within the limits of the manufacturer’s specification;
loss of frame alignment or loss of synchronization is not allowed during each individual exposure.
For selected frequencies :
it shall be possible to establish a connection between two ports;
it shall be possible to clear a connection in a controlled manner.
6.5.3
Specific performance criteria of EN 300 386, Section 12 (Transmission equipment specific requirements)
6.5.3.1 12.3.1 Digital signal ports
Performance criterion A:
The performance of the equipment shall be verified by measuring the additional errors induced due to the
application of any electromagnetic phenomena. During the test sweep the established connection shall be
maintained throughout the testing and the transfer of information shall be without any reproducible bit errors. If
degradation in performance is observed and the system is adaptive i.e. has capability to automatically re-train in the
presence of an interfering signal, then for conducted immunity tests only the following procedure shall be followed:
- For each range of interfering frequencies, where degradation in performance is observed, three frequencies
(beginning, middle and end) shall be identified.
- At each of the frequencies identified in step 1, the interfering signal shall be turned and the system allowed to
re-train. If the system is able to re-train and then function with respect to the performance criteria A then the system
performance is considered acceptable.
- The frequencies identified in step 1 shall be recorded in the test report.
6.6
Acceptance criteria
Data packets shall be transmitted from TI chip, using its internal PRBS generator to an external loopback, which
returns the packets to TI chip to compare to transmitted packets. No data packets error is allowed during the test.
Page 7 of 30
Report ID: TEXEMC_EN.23555_rev1.docx
Date of Issue: 14-Apr-13
Test specification:
Section 6 Class B, Radiated disturbance
Test procedure:
Test mode:
Date(s):
Temperature: 22 ºC
Remarks:
EN 55022, Section 10
Compliance
12/12/2012
Air Pressure: 1018 hPa
Verdict:
Relative Humidity: 45 %
PASS
Power Supply: 5 VDC
7
Emissions tests
7.1
Radiated disturbance
7.1.1
General
This test was performed to measure radiated disturbance from the EUT enclosure. The specification test limits are
given in Table 7.1.1.
Table 7.1.1 Radiated disturbance limits
Frequency,
MHz
Class B limit,
dB(V/m)
Peak
Quasi-peak
Average
@3 m
@3 m
@10 m
@3 m
30 - 230
–––
30.0
40.5*
–––
230 - 1000
–––
37.0
47.5*
–––
1000 – 3000
70
–––
–––
50
3000 - 6000
74
–––
–––
54
* The limit for test distance other than specified was calculated using the inverse linear distance extrapolation factor
as follows: LimS2 = LimS1 + 20 log (S1/S2),
where S1 and S2 – standard defined and test distance respectively in meters.
7.1.2
Test procedure
7.1.2.1 The EUT was set up as shown in Figure 7.1.1 and the associated photographs, energized and the EUT
performance was checked.
7.1.2.2 The preliminary measurements were performed in the anechoic chamber at 3 m test distance. The specified
frequency range was investigated with the antenna connected to the EMI receiver. To find maximum radiation the
turntable was rotated 3600 and the measuring antenna height was swept from 1 to 4 m in both, vertical and
horizontal polarizations.
7.1.2.3 The worst test results for radiation through cable with respect to the limits were recorded in Table 7.1.2 and shown
in the associated plots.
7.1.2.4 The test was repeated for evaluation of radiation from pins, the test results are shown in the associated plots.
Page 8 of 30
Report ID: TEXEMC_EN.23555_rev1.docx
Date of Issue: 14-Apr-13
Test specification:
Section 6 Class B, Radiated disturbance
Test procedure:
Test mode:
Date(s):
Temperature: 22 ºC
Remarks:
EN 55022, Section 10
Compliance
12/12/2012
Air Pressure: 1018 hPa
Verdict:
Relative Humidity: 45 %
PASS
Power Supply: 5 VDC
Figure 7.1.1 Setup for radiated emissions measurements in anechoic chamber, table-top EUT
1.5 m
Anechoic chamber
Test
antenna
RF absorbing
material
Ferrites
Test distance
EUT
Test
antenna
Flush
mounted
turn table
Auxilliary
equipment
1.0m
0.80m
Wooden
table
Ground plane
Power
supply
PC
EMI
receiver
Page 9 of 30
Report ID: TEXEMC_EN.23555_rev1.docx
Date of Issue: 14-Apr-13
Test specification:
Section 6 Class B, Radiated disturbance
Test procedure:
Test mode:
Date(s):
Temperature: 22 ºC
Remarks:
EN 55022, Section 10
Compliance
12/12/2012
Air Pressure: 1018 hPa
Verdict:
Relative Humidity: 45 %
PASS
Power Supply: 5 VDC
Photograph 7.1.1 Setup for preliminary radiated disturbance measurements, general view,
EUT radiation through cable
Photograph 7.1.2 Setup for preliminary radiated disturbance measurements, general view,
EUT radiation through cable
Page 10 of 30
Report ID: TEXEMC_EN.23555_rev1.docx
Date of Issue: 14-Apr-13
Test specification:
Section 6 Class B, Radiated disturbance
Test procedure:
Test mode:
Date(s):
Temperature: 22 ºC
Remarks:
EN 55022, Section 10
Compliance
12/12/2012
Air Pressure: 1018 hPa
Verdict:
Relative Humidity: 45 %
PASS
Power Supply: 5 VDC
Photograph 7.1.3 Setup for radiated disturbance measurements, EUT radiation through cable
Photograph 7.1.4 Setup for radiated disturbance measurements, EUT close view
Page 11 of 30
Report ID: TEXEMC_EN.23555_rev1.docx
Date of Issue: 14-Apr-13
Test specification:
Section 6 Class B, Radiated disturbance
Test procedure:
Test mode:
Date(s):
Temperature: 22 ºC
Remarks:
EN 55022, Section 10
Compliance
12/12/2012
Air Pressure: 1018 hPa
PASS
Verdict:
Relative Humidity: 45 %
Power Supply: 5 VDC
Table 7.1.2 Radiated disturbance test results
EUT SET UP:
TEST SITE:
TEST DISTANCE:
DETECTORS USED:
FREQUENCY RANGE:
RESOLUTION BANDWIDTH:
TLK110 48p QFP radiation through cable
Quasi-peak
Peak
Frequency,
Measured
Limit,
emission,
emission,
MHz
dB(V/m)
dB(V/m)
dB(V/m)
Note*
122.83
35.54
40.5
Note*
32.00
37.00
40.5
*Note:Quasi-peak emission was not measured
TABLE-TOP
Fully anecoic chamber
3m
PEAK / QUASI-PEAK
30 MHz – 1000 MHz
120 kHz
Margin,
to peak
dB*
-4.96
-3.50
Antenna
polarization
Antenna
height,
m
Turn-table
position**,
degrees
Verdict
Vertical
Vertical
Note*
Note*
Note*
Note*
Pass*
DETECTORS USED:
PEAK / AVERAGE
FREQUENCY RANGE:
1000 MHz – 2900 MHz
RESOLUTION BANDWIDTH:
1000 kHz
TEST SITE:
Fully anecoic chamber
TEST DISTANCE:
3m
TLK110 48p QFP radiation through cable
Peak
Average
Frequency,
Antenna Turn-table
Measured
Limit, Margin, Measured Limit, Margin, Antenna
height, position**, Verdict
emission,
emission,
polarization
MHz
m
degrees
dB(V/m) dB(V/m) dB* dB(V/m) dB(V/m) dB*
No emissions were found
Pass
Reference numbers of test equipment used
HL 2432
HL 2697
HL 4150
HL 4347
HL 4349
Full description is given in Appendix A.
Page 12 of 30
Report ID: TEXEMC_EN.23555_rev1.docx
Date of Issue: 14-Apr-13
Test specification:
Section 6 Class B, Radiated disturbance
Test procedure:
Test mode:
Date(s):
Temperature: 22 ºC
Remarks:
EN 55022, Section 10
Compliance
12/12/2012
Air Pressure: 1018 hPa
Verdict:
Relative Humidity: 45 %
PASS
Power Supply: 5 VDC
Plot 7.1.1 Radiated disturbance measurements in 30 - 1000 MHz range, vertical antenna polarization
TEST SITE:
TEST DISTANCE:
Fully anecoic chamber
3m
TLK110 48p QFP radiation through cable
Plot 7.1.2 Radiated disturbance measurements in 30 - 1000 MHz range, horizontal antenna polarization
TEST SITE:
TEST DISTANCE:
Fully anecoic chamber
3m
TLK110 48p QFP radiation through cable
Page 13 of 30
Report ID: TEXEMC_EN.23555_rev1.docx
Date of Issue: 14-Apr-13
Test specification:
Section 6 Class B, Radiated disturbance
Test procedure:
Test mode:
Date(s):
Temperature: 22 ºC
Remarks:
EN 55022, Section 10
Compliance
12/12/2012
Air Pressure: 1018 hPa
Verdict:
Relative Humidity: 45 %
PASS
Power Supply: 5 VDC
Plot 7.1.3 Radiated disturbance measurements in 1000 – 2900 MHz range, vertical antenna polarization
TEST SITE:
TEST DISTANCE:
Fully anecoic chamber
3m
TLK110 48p QFP radiation through cable
Plot 7.1.4 Radiated disturbance measurements in 1000 – 2900 MHz range, horizontal antenna polarization
TEST SITE:
TEST DISTANCE:
Fully anecoic chamber
3m
TLK110 48p QFP radiation through cable
Page 14 of 30
Report ID: TEXEMC_EN.23555_rev1.docx
Date of Issue: 14-Apr-13
Test specification:
Section 6 Class B, Radiated disturbance
Test procedure:
Test mode:
Date(s):
Temperature: 22 ºC
Remarks:
EN 55022, Section 10
Compliance
12/12/2012
Air Pressure: 1018 hPa
Verdict:
Relative Humidity: 45 %
PASS
Power Supply: 5 VDC
Photograph 7.1.5 Setup for radiated disturbance measurements, radiation from EUT pins
Photograph 7.1.6 Setup for radiated disturbance measurements, radiation from EUT pins
Page 15 of 30
Report ID: TEXEMC_EN.23555_rev1.docx
Date of Issue: 14-Apr-13
Test specification:
Section 6 Class B, Radiated disturbance
Test procedure:
Test mode:
Date(s):
Temperature: 22 ºC
Remarks:
EN 55022, Section 10
Compliance
12/12/2012
Air Pressure: 1018 hPa
Verdict:
Relative Humidity: 45 %
PASS
Power Supply: 5 VDC
Photograph 7.1.7 Setup for radiated disturbance measurements, radiation from EUT pins
Page 16 of 30
Report ID: TEXEMC_EN.23555_rev1.docx
Date of Issue: 14-Apr-13
Test specification:
Section 6 Class B, Radiated disturbance
Test procedure:
Test mode:
Date(s):
Temperature: 22 ºC
Remarks:
EN 55022, Section 10
Compliance
12/12/2012
Air Pressure: 1018 hPa
Verdict:
Relative Humidity: 45 %
PASS
Power Supply: 5 VDC
Plot 7.1.5 Radiated disturbance measurements in 30 - 1000 MHz range, vertical antenna polarization
TEST SITE:
TEST DISTANCE:
Fully anecoic chamber
3m
TLK110 48p QFP radiation from EUT pins
Note: To find the highest emission the measuring antenna height was swept from 1 to 1.8 m (turntable was not rotated)
Plot 7.1.6 Radiated disturbance measurements in 30 - 1000 MHz range, horizontal antenna polarization
TEST SITE:
TEST DISTANCE:
Fully anecoic chamber
3m
TLK110 48p QFP radiation from EUT pins
Note: To find the highest emission the measuring antenna height was swept from 1 to 1.8 m (turntable was not rotated)
Page 17 of 30
Report ID: TEXEMC_EN.23555_rev1.docx
Date of Issue: 14-Apr-13
Test specification:
Section 6 Class B, Radiated disturbance
Test procedure:
Test mode:
Date(s):
Temperature: 22 ºC
Remarks:
EN 55022, Section 10
Compliance
12/12/2012
Air Pressure: 1018 hPa
Verdict:
Relative Humidity: 45 %
PASS
Power Supply: 5 VDC
Plot 7.1.7 Radiated disturbance measurements in 1000 – 2900 MHz range, vertical antenna polarization
TEST SITE:
TEST DISTANCE:
Fully anecoic chamber
3m
TLK110 48p QFP radiation from EUT pins
Note: To find the highest emission the measuring antenna height was swept from 1 to 1.8 m (turntable was not rotated)
Plot 7.1.8 Radiated disturbance measurements in 1000 – 2900 MHz range, horizontal antenna polarization
TEST SITE:
TEST DISTANCE:
Fully anecoic chamber
3m
TLK110 48p QFP radiation from EUT pins
Note: To find the highest emission the measuring antenna height was swept from 1 to 1.8 m (turntable was not rotated)
Page 18 of 30
Report ID: TEXEMC_EN.23555_rev1.docx
Date of Issue: 14-Apr-13
Test specification:
Radiated immunity to radio frequency electromagnetic field
Test procedure:
Test mode:
Date(s):
Temperature: 23 ºC
Remarks:
EN 61000-4-3; EN 55024, Section 4.2.3.1
Evaluation
Verdict:
12/12/2012
Air Pressure: 1018 hPa
Relative Humidity: 39 %
PASS
Power Supply: 5 VDC
8
Immunity tests
8.1
Radiated immunity to radio frequency electromagnetic field
8.1.1
General
This test was performed to verify the EUT immunity to radiated radio frequency electromagnetic field.
The radiated RF electromagnetic field levels, performance criterion and test results are referred to in Table 8.1.1.
8.1.2
Test procedure
8.1.2.1 The EUT was set up as shown in Figure 8.1.1 and the associated photographs, energized and the EUT
performance was checked.
8.1.2.2 The electric field generating antenna was installed facing the EUT front panel at the specified distance.
8.1.2.3 The test setup was adjusted to produce the required field strength level. The field strength was monitored by the
isotropic field probe, which was placed near the EUT.
8.1.2.4 The signal frequency was scanned throughout the frequency range.
8.1.2.5 The test was performed with antenna/s in both vertical and horizontal polarizations.
8.1.2.6 The test was repeated at selected frequencies.
8.1.2.7 The EUT operation was monitored throughout the test for any malfunction or degradation and its performance was
recorded.
8.1.2.8 Upon this the test was completed.
Page 19 of 30
Report ID: TEXEMC_EN.23555_rev1.docx
Date of Issue: 14-Apr-13
Test specification:
Radiated immunity to radio frequency electromagnetic field
Test procedure:
Test mode:
Date(s):
Temperature: 23 ºC
Remarks:
EN 61000-4-3; EN 55024, Section 4.2.3.1
Evaluation
Verdict:
12/12/2012
Air Pressure: 1018 hPa
Relative Humidity: 39 %
PASS
Power Supply: 5 VDC
Figure 8.1.1 Setup for radiated immunity to RF electromagnetic field test, table-top EUT
Test chamber
Antenna
mast
Test distance
E-field probe
Transmit
antenna
1meter of the EUT
cable aligned with
front side
0.80m
Wooden
table
1.55 m
EUT
Bulkhead
RF connector
Turn table
Auxilliary
equipment
E-field
monitor
RF signal
generator
RF Power
amplifier
Directional
coupler
Optical
link
Power
supply
Personal
computer
Power
Meter
Page 20 of 30
Report ID: TEXEMC_EN.23555_rev1.docx
Date of Issue: 14-Apr-13
Test specification:
Radiated immunity to radio frequency electromagnetic field
Test procedure:
Test mode:
Date(s):
Temperature: 23 ºC
Remarks:
EN 61000-4-3; EN 55024, Section 4.2.3.1
Evaluation
Verdict:
12/12/2012
Air Pressure: 1018 hPa
Relative Humidity: 39 %
PASS
Power Supply: 5 VDC
Photograph 8.1.1 Setup for radiated immunity to RF electromagnetic field test, general view,
EUT radiation through cable
Photograph 8.1.2 Setup for radiated immunity to RF electromagnetic field test, EUT close view,
EUT radiation through cable
Page 21 of 30
Report ID: TEXEMC_EN.23555_rev1.docx
Date of Issue: 14-Apr-13
Test specification:
Radiated immunity to radio frequency electromagnetic field
Test procedure:
Test mode:
Date(s):
Temperature: 23 ºC
Remarks:
EN 61000-4-3; EN 55024, Section 4.2.3.1
Evaluation
Verdict:
12/12/2012
Air Pressure: 1018 hPa
Relative Humidity: 39 %
PASS
Power Supply: 5 VDC
Photograph 8.1.3 Setup for radiated immunity to RF electromagnetic field test, general view,
radiation from EUT pins
Photograph 8.1.4 Setup for radiated immunity to RF electromagnetic field test, general view,
radiation from EUT pins
Page 22 of 30
Report ID: TEXEMC_EN.23555_rev1.docx
Date of Issue: 14-Apr-13
Test specification:
Radiated immunity to radio frequency electromagnetic field
Test procedure:
Test mode:
Date(s):
Temperature: 23 ºC
Remarks:
EN 61000-4-3; EN 55024, Section 4.2.3.1
Evaluation
Verdict:
12/12/2012
Air Pressure: 1018 hPa
Relative Humidity: 39 %
PASS
Power Supply: 5 VDC
Photograph 8.1.5 Setup for radiated immunity to RF electromagnetic field test, EUT close view,
radiation from EUT pins
Page 23 of 30
Report ID: TEXEMC_EN.23555_rev1.docx
Date of Issue: 14-Apr-13
Test specification:
Radiated immunity to radio frequency electromagnetic field
Test procedure:
Test mode:
Date(s):
Temperature: 23 ºC
Remarks:
EN 61000-4-3; EN 55024, Section 4.2.3.1
Evaluation
Verdict:
12/12/2012
Air Pressure: 1018 hPa
Relative Humidity: 39 %
PASS
Power Supply: 5 VDC
Table 8.1.1 Radiated immunity to RF electromagnetic field test results
TLK110 48p QFP radiation through cable
EUT SET UP:
PERFORMANCE CRITERIA:
TEST SITE:
ANTENNA TO EUT DISTANCE:
FREQUENCY RANGE:
MODULATION:
DWELL TIME:
FREQUENCY STEP:
EUT
orientation*
Antenna
polarization
TABLE-TOP
A
FULLY ANECHOIC CHAMBER
2.4 m
80 – 1000 MHz
80% AM with 1 kHz
2.8 s
1 % of current frequency
Field strength**,
Vrms/m
Vertical
10***
Horizontal
* - 0 = antenna installed facing the EUT front panel.
**- Field strength measured prior to modulation.
*** - The standard requirement is 3 Vrms/m.
The found threshold was 8 Vrms/m.
0
EUT performance description during the test
Verdict
NP
At 89.49 MHz and 97.61 MHz the errors appeared
Pass***
TLK110 48p QFP radiation from EUT pins
EUT SET UP:
PERFORMANCE CRITERIA:
TEST SITE:
ANTENNA TO EUT DISTANCE:
FREQUENCY RANGE:
MODULATION:
DWELL TIME:
FREQUENCY STEP:
EUT
orientation*
Antenna
polarization
Field strength**,
Vrms/m
EUT performance description during the test
10***
At 81, 130, 184, 226, 350, 489, 707, 960 MHz the
errors appeared; the threshold 5 V at 707 MHz
At 81, 115, 130, 160, 197, 525, 551, 743 MHz the
errors appeared
Vertical
0
TABLE-TOP
A
MILITARY STD ANECHOIC CHAMBER
2.0 m
80 – 1000 MHz
80% AM with 1 kHz
2.8 s
1 % of current frequency
Horizontal
Verdict
Pass***
Tested
* - 0 = antenna installed facing the EUT front panel.
**- Field strength measured prior to modulation.
*** - The standard requirement is 3 Vrms/m.
***The 5 Vrms/m threshold was defined for 707 MHz only.
Reference numbers of test equipment used
HL 0317
HL 0613
HL 0659
HL 2109
HL 2376
HL 2432
Full description is given in Appendix A.
HL 0674
HL 2697
HL 1097
HL 2783
HL 1544
HL 2788
HL 1629
HL 3158
HL 2078
HL 3508
Page 24 of 30
Report ID: TEXEMC_EN.23555_rev1.docx
Date of Issue: 14-Apr-13
9 APPENDIX A
HL
No
0317
0613
0659
0674
Test equipment and ancillaries used for tests
Description
Power Sensor, 30 MHz - 18 GHz, -70 to
20 dBm
Sensor Electric Field 10 kHz-1.0 GHz,
1-300 V/m (probe)
Amplifier 1 to 4 GHz, 55 W
1544
1629
Coupler Directional, high power
80 - 1000 MHz, 1500 W
Attenuator, 50 Ohm, 5 W, DC to 8 GHz,
20 dB
Cable RF, N/N-type, 3.2 m
Isotropic Field Monitor
2078
Isotropic Field Probe 80 MHz - 40 GHz
2109
Anechoic Chamber 6(L) x 5.5(W) x
2.95(H) m
Coupler coaxial bi-directional 1 - 4 GHz,
20 dB
Antenna, Double-Ridged Waveguide Horn
1-18 GHz
Antenna, 30 MHz - 3.0 GHz
1097
2376
2432
2697
2783
Power Meter, RF, IEEE-488, 100 kHz 100 GHz, -70 to +37 dBm
2788
3158
Horn Antenna, 0.5 to 4 GHz
Amplifier, 80 to 1000 MHz, 500 W
3508
MIL STD Anechoic Chamber 6.0(L) x
4.8(W) x 2.9(H) m
Preamplifier, 0.1 to 18 GHz, Gain 25 dB,
N-type(f) in, N-type(m) out.
Low Loss Armored Test Cable,
DC - 18 GHz, 2.0 m, N type-M/N type-M
Low Loss Armored Test Cable,
DC - 18 GHz, 4.5 m, N type-M/N type-M
4150
4347
4349
Manufacturer
51072
26163
Last Cal./
Check
01-Jan-13
FP2000
18677
07-Dec-12
07-Dec-13
AS010455/55B
C3908
971386
03-Jul-12
03-Jul-13
5843
01-Jan-13
01-Jan-14
Midwest
Microwave
Alpha Wire
Amplifier
Research
Amplifier
Research
Hermon
Laboratories
Narda
0793-20NN-07
RG-213/U
FM2000
1097
10-Oct-12
10-Oct-13
1544
23308
19-Jul-12
07-Dec-12
19-Jul-13
07-Dec-13
FP2080
302541
10-Feb-13
10-Feb-14
AC-2
2109
07-Nov-12
07-Nov-13
3022
50076
21-Jun-12
21-Jun-13
EMC Test
Systems
Sunol
Sciences.
Corp.
Pleasanton,
California USA
Boonton
Electronics
Corp.
GTE Sylvania
Amplifier
Research
ETS Lindgren
3115
00027177
07-Dec-12
07-Dec-13
JB3
A022805
20-May-12
20-May-14
4220
156602BK
02-Jan-13
02-Jan-14
AN-10E
500W100
0A
RFD-F/A100
87405C
78004
032960
30-Jul-10
03-Apr-13
30-Jul-13
03-Apr-14
4311
30-Oct-12
30-Oct-13
MY470105
91
12025103
001
12025102
001
18-Jun-12
18-Jun-13
06-Mar-13
06-Mar-14
01-Jan-13
01-Jan-14
Boonton
Electronics
Corp.
Amplifier
Research
Milmega
WERLATONE
Agilent
Technologies
MegaPhase
MegaPhase
Model
NC29N1N1-79
NC29N1N1-177
Ser. No.
Due Cal./
Check
01-Jan-14
Page 25 of 30
Report ID: TEXEMC_EN.23555_rev1.docx
Date of Issue: 14-Apr-13
10
APPENDIX B
Measurement uncertainties
Expanded uncertainty at 95% confidence in Hermon Labs EMC measurements
Test description
Radiated emissions at 3 m measuring distance
Horizontal polarization
Vertical polarization
Radiated immunity
AR FP2000 E-field probe
AR FP2080 E-field probe
Expanded uncertainty
Biconilog antenna:  5.3 dB
Biconical antenna:  5.0 dB
Log periodic antenna:  5.3 dB
Double ridged horn antenna:  5.3 dB
Biconilog antenna:  6.0 dB
Biconical antenna:  5.7 dB
Log periodic antenna:  6.0 dB
Double ridged horn antenna:  6.0 dB
10 kHz to 250 MHz:  1.9 dB; 250 MHz to 1 GHz:  2.1 dB
80 MHz to 26 GHz:  2.7 dB; 26 GHz to 40 GHz:  4.0 dB
Hermon Laboratories is accredited by A2LA for calibration according to present requirements of ISO/IEC 17025 and NCSL
Z540-1. The accreditation is granted to perform calibration of parameters that are listed in the Scope of Hermon Laboratories
Accreditation.
Hermon Laboratories calibrates its reference and transfer standards by calibration laboratories accredited to ISO/IEC 17025
by a mutually recognized Accreditation Body or by a recognized national metrology institute. All reference and transfer
standards used in the calibration system are traceable to national or international standards.
In-house calibration of all test and measurement equipment is performed on a regular basis according to Hermon
Laboratories calibration procedures, manufacturer calibration/verification procedures or procedures defined in the relevant
standards. The Hermon Laboratories test and measurement equipment is calibrated within the tolerances specified by the
manufacturers and/or by the relevant standards.
Page 26 of 30
Report ID: TEXEMC_EN.23555_rev1.docx
Date of Issue: 14-Apr-13
11
APPENDIX C
Test laboratory description
Tests were performed at Hermon Laboratories Ltd., which is a fully independent, private, EMC, safety, environmental and
telecommunication testing facility.
Hermon Laboratories is listed by the Federal Communications Commission (USA) for all parts of Code of Federal
Regulations 47 (CFR 47), Registration Numbers 90624 for OATS and 90623 for the anechoic chamber; by Industry Canada
for electromagnetic emissions (file numbers IC 2186A-1 for OATS and IC 2186A-2 for anechoic chamber), certified by VCCI,
Japan (the registration numbers are R-808 for OATS, R-1082 for semi anechoic chamber, G-27 for full-anechoic chamber,
C-845 for conducted emissions (mains ports) site, T-1606 for conducted emissions (telecommunication ports) site), has a
status of a Telefication - Listed Testing Laboratory, Certificate No. L138/00. The laboratory is accredited by American
Association for Laboratory Accreditation (USA) according to ISO/IEC 17025 for electromagnetic compatibility, product safety,
telecommunications testing and environmental simulation (for exact scope please refer to Certificate No. 839.01).
Address:
Telephone:
Fax:
e-mail:
website:
P.O. Box 23, Binyamina 30500, Israel.
+972 4628 8001
+972 4628 8277
mail@hermonlabs.com
www.hermonlabs.com
Person for contact: Mr. Alex Usoskin, CEO.
12
APPENDIX D
Specification references
EN 300 386 V1.4.1: 2008
Electromagnetic compatibility and Radio spectrum Matters (ERM).
Telecommunication network equipment. ElectroMagnetic Compatibility (EMC)
requirements
EN 55022: 2010
Limits and methods of measurement of interference characteristics of information
technology equipment
CISPR 16-1-1: 2006
Specification for radio disturbance and immunity measuring apparatus and
methods. Part 1-1: Radio disturbance and immunity measuring apparatus –
Measuring apparatus
EN 61000-4-3: 2006+A1(08)+A2(10)
Electromagnetic compatibility (EMC). Part 4: testing and measurement techniques.
Section 3: Radiated, radio frequency, electromagnetic field immunity test
Page 27 of 30
Report ID: TEXEMC_EN.23555_rev1.docx
Date of Issue: 14-Apr-13
13 APPENDIX E
Test equipment correction factors
Antenna factor
Double-ridged guide horn antenna
Model 3115, serial number: 00027177, HL 2432
Frequency,
MHz
1000.0
1500.0
2000.0
2500.0
3000.0
3500.0
4000.0
4500.0
5000.0
5500.0
6000.0
6500.0
7000.0
7500.0
8000.0
8500.0
9000.0
9500.0
10000.0
10500.0
11000.0
11500.0
12000.0
12500.0
13000.0
13500.0
14000.0
14500.0
15000.0
15500.0
16000.0
16500.0
17000.0
17500.0
18000.0
Antenna factor.
dB(1/m)
24.7
25.7
27.8
28.9
30.7
31.8
33.0
32.8
34.2
34.9
35.2
35.4
36.3
37.3
37.5
38.0
38.3
38.3
38.7
38.7
38.9
39.5
39.5
39.4
40.5
40.8
41.5
41.3
40.2
38.7
38.5
39.8
41.9
45.8
49.1
Antenna factor in dB(1/m) is to be added to receiver meter reading in dB(V) to convert it into field strength in dB(V/m).
Page 28 of 30
Report ID: TEXEMC_EN.23555_rev1.docx
Date of Issue: 14-Apr-13
Antenna calibration
Sunol Sciences Inc., model JB3, serial number A022805, HL 2697
Frequency,
MHz
ACF,
dB
Gain,
dBi
Num gain
Frequency,
MHz
ACF,
dB
Gain,
dBi
Num gain
Frequency,
MHz
ACF,
dB
Gain,
dBi
Num gain
Frequency,
MHz
ACF,
dB
Gain,
dBi
Num gain
Frequency,
MHz
ACF,
dB
Gain,
dBi
Num
gain
30
35
40
45
45
50
55
60
65
70
75
80
85
90
95
100
110
120
125
130
140
150
160
165
170
175
180
185
190
200
205
210
215
220
225
230
235
240
245
250
255
260
265
270
275
280
285
290
295
300
305
310
315
320
325
330
335
340
345
350
355
360
365
370
375
380
385
390
395
400
405
410
415
420
425
430
435
440
445
450
455
460
465
470
475
480
485
490
495
500
505
510
515
520
525
530
535
540
545
550
555
560
565
570
575
580
590
595
600
610
615
22.2
18.5
14.7
11.3
11.3
8.9
7.9
7.8
8.5
9.0
8.8
8.4
8.0
8.2
9.2
10.6
12.6
13.9
14.2
14.2
13.4
12.9
12.7
12.5
12.2
11.8
11.6
11.5
11.6
13.1
12.0
11.0
11.3
11.6
11.7
11.9
12.1
12.3
12.3
12.3
12.5
12.7
13.2
13.7
13.7
13.7
13.7
13.7
13.8
13.9
14.0
14.1
14.3
14.4
14.5
14.6
14.7
14.7
14.9
15.1
15.3
15.6
15.5
15.5
15.6
15.7
15.7
15.7
15.9
16.0
16.3
16.5
16.5
16.6
16.6
16.7
16.9
17.1
17.2
17.2
17.3
17.4
17.5
17.6
17.7
17.9
18.0
18.2
18.0
17.9
17.9
18.0
18.1
18.2
18.2
18.3
18.3
18.4
18.4
18.4
18.6
18.8
18.9
19.0
19.1
19.1
19.1
19.0
19.0
19.1
19.4
-22.5
-17.4
-12.5
-8.1
-8.1
-4.7
-2.8
-2.1
-2.0
-1.9
-1.1
-0.2
0.8
1.1
0.5
-0.4
-1.6
-2.1
-2.0
-1.7
-0.3
0.8
1.6
2.0
2.6
3.3
3.7
4.0
4.2
3.2
4.4
5.6
5.6
5.5
5.5
5.5
5.5
5.5
5.7
5.9
5.9
5.8
5.5
5.2
5.3
5.4
5.6
5.7
5.8
5.8
5.9
5.9
5.9
5.9
5.9
5.9
6.0
6.2
6.1
6.0
5.9
5.8
5.9
6.0
6.1
6.1
6.2
6.3
6.3
6.2
6.1
6.0
6.0
6.1
6.1
6.2
6.1
5.9
6.0
6.0
6.1
6.1
6.1
6.1
6.0
5.9
5.9
5.8
6.0
6.3
6.3
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.5
6.6
6.5
6.4
6.4
6.3
6.3
6.4
6.6
6.6
6.7
6.8
6.5
0.01
0.02
0.06
0.16
0.16
0.34
0.52
0.62
0.63
0.64
0.78
0.97
1.20
1.29
1.13
0.92
0.70
0.62
0.63
0.68
0.94
1.21
1.44
1.59
1.83
2.13
2.36
2.54
2.61
2.07
2.76
3.66
3.59
3.52
3.55
3.57
3.56
3.54
3.71
3.88
3.85
3.83
3.54
3.27
3.39
3.50
3.61
3.72
3.77
3.81
3.85
3.88
3.89
3.90
3.92
3.93
4.02
4.12
4.06
3.99
3.88
3.78
3.89
4.01
4.03
4.05
4.15
4.25
4.22
4.18
4.07
3.96
4.00
4.03
4.10
4.16
4.05
3.93
3.97
4.00
4.04
4.07
4.05
4.04
3.99
3.93
3.88
3.82
4.02
4.23
4.29
4.36
4.34
4.32
4.36
4.39
4.41
4.41
4.47
4.53
4.45
4.37
4.33
4.28
4.31
4.33
4.52
4.62
4.72
4.76
4.51
620
625
630
635
640
645
650
655
660
665
670
675
680
685
690
695
705
715
720
725
735
745
755
760
765
770
775
780
785
795
800
805
810
815
820
825
830
835
840
845
850
855
860
865
870
875
880
885
890
895
900
905
910
915
920
925
930
935
940
945
950
955
960
965
970
975
980
985
990
995
1000
1005
1010
1015
1020
1025
1030
1035
1040
1045
1050
1055
1060
1065
1070
1075
1080
1085
1090
1095
1100
1105
1110
1115
1120
1125
1130
1135
1140
1145
1150
1155
1160
1165
1170
1175
1185
1190
1195
1205
1210
19.7
19.7
19.6
19.7
19.9
19.9
19.9
19.9
19.9
19.9
20.0
20.1
20.1
20.1
20.1
20.2
20.4
20.5
20.5
20.6
20.9
21.0
21.0
21.0
21.1
21.3
21.3
21.3
21.3
21.4
21.5
21.6
21.7
21.7
21.7
21.7
21.7
21.8
21.9
21.9
21.9
22.0
22.1
22.0
21.9
22.0
22.1
22.1
22.1
22.2
22.2
22.3
22.3
22.4
22.6
22.7
22.8
22.8
22.8
22.8
22.9
23.0
23.1
23.1
23.2
23.3
23.5
23.5
23.6
23.6
23.7
23.7
23.7
23.7
23.8
23.8
23.7
23.7
23.6
23.7
23.7
23.7
23.6
23.7
23.8
23.8
23.9
24.0
24.0
24.1
24.2
24.3
24.3
24.3
24.4
24.3
24.3
24.4
24.5
24.6
24.7
24.7
24.7
24.7
24.7
24.8
24.8
24.7
24.7
24.08
24.8
6.3
6.5
6.6
6.5
6.4
6.5
6.5
6.6
6.7
6.7
6.7
6.7
6.7
6.8
6.9
6.8
6.8
6.8
6.9
6.8
6.7
6.6
6.8
6.8
6.8
6.7
6.7
6.7
6.8
6.8
6.8
6.7
6.7
6.7
6.8
6.8
6.9
6.8
6.8
6.8
6.9
6.8
6.8
6.9
7.1
7.1
7.0
7.0
7.0
7.1
7.1
7.1
7.0
7.0
6.9
6.9
6.8
6.8
6.9
6.9
6.9
6.8
6.8
6.7
6.7
6.6
6.6
6.6
6.5
6.5
6.5
6.5
6.6
6.6
6.6
6.6
6.7
6.8
6.9
6.9
6.9
7.0
7.1
7.0
7.0
7.0
7.0
7.0
6.9
6.9
6.8
6.8
6.8
6.8
6.8
6.9
7.0
6.9
6.8
6.8
6.7
6.8
6.8
6.8
6.8
6.8
6.9
7.0
7.0
7.1
7.1
4.27
4.42
4.57
4.48
4.40
4.45
4.51
4.60
4.69
4.70
4.71
4.71
4.71
4.79
4.88
4.82
4.75
4.80
4.85
4.81
4.65
4.59
4.74
4.83
4.73
4.64
4.68
4.72
4.77
4.79
4.77
4.71
4.65
4.72
4.80
4.82
4.85
4.82
4.80
4.83
4.86
4.80
4.74
4.92
5.11
5.08
5.05
5.06
5.06
5.09
5.12
5.09
5.05
4.99
4.92
4.85
4.77
4.83
4.89
4.87
4.85
4.81
4.77
4.73
4.69
4.62
4.54
4.52
4.50
4.48
4.46
4.51
4.57
4.55
4.54
4.62
4.70
4.81
4.92
4.91
4.91
5.01
5.11
5.06
5.01
5.01
5.01
4.96
4.91
4.86
4.82
4.80
4.78
4.79
4.80
4.90
5.00
4.90
4.81
4.76
4.71
4.76
4.80
4.81
4.81
4.84
4.92
4.99
5.02
5.08
5.11
1215
1220
1225
1230
1235
1240
1245
1250
1255
1260
1265
1270
1275
1280
1285
1290
1300
1310
1315
1320
1330
1340
1350
1355
1360
1365
1370
1375
1380
1390
1395
1400
1405
1410
1415
1420
1425
1430
1435
1440
1445
1450
1455
1460
1465
1470
1475
1480
1485
1490
1495
1500
1505
1510
1515
1520
1525
1530
1535
1540
1545
1550
1555
1560
1565
1570
1575
1580
1585
1590
1595
1600
1605
1610
1615
1620
1625
1630
1635
1640
1645
1650
1655
1660
1665
1670
1675
1680
1685
1690
1695
1700
1705
1710
1715
1720
1725
1730
1735
1740
1745
1750
1755
1760
1765
1770
1780
1785
1790
1800
1805
24.9
24.9
25.1
25.2
25.1
25.0
25.0
25.0
25.0
24.9
25.0
25.1
25.3
25.5
25.4
25.3
25.2
25.5
25.4
25.3
25.6
25.7
25.7
25.8
25.9
26.0
26.0
26.0
26.0
26.1
26.2
26.2
26.1
26.1
26.2
26.3
26.2
26.1
26.1
26.2
26.3
26.5
26.4
26.4
26.4
26.4
26.4
26.5
26.5
26.5
26.5
26.5
26.5
26.6
26.6
26.5
26.6
26.6
26.6
26.5
26.5
26.5
26.7
26.9
26.9
26.9
27.0
27.0
27.0
27.0
27.0
27.0
27.0
27.0
27.1
27.2
27.2
27.2
27.2
27.2
27.3
27.5
27.5
27.5
27.6
27.7
27.7
27.7
27.7
27.8
27.8
27.8
27.8
27.7
27.8
27.9
28.0
28.0
28.0
28.0
28.0
28.1
27.9
27.8
27.9
27.9
27.9
28.1
28.2
28.3
28.3
7.0
7.0
6.9
6.8
7.0
7.1
7.1
7.1
7.2
7.3
7.3
7.2
7.0
6.8
7.0
7.1
7.3
7.1
7.2
7.3
7.0
7.1
7.1
7.0
6.9
6.9
7.0
7.0
7.0
6.9
6.9
7.0
7.0
7.1
7.0
7.0
7.1
7.2
7.2
7.2
1
7.0
7.1
7.1
7.2
7.2
7.1
7.1
7.1
7.1
7.2
7.2
7.2
7.2
7.2
7.3
7.3
7.3
7.4
7.4
7.5
7.5
7.3
7.1
7.2
7.2
7.2
7.1
7.2
7.2
7.2
7.3
7.3
7.3
7.3
7.2
7.2
7.3
7.3
7.3
7.2
7.1
7.1
7.1
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.1
7.1
7.1
7.0
7.0
7.0
7.0
7.1
7.0
7.0
7.1
7.3
7.3
7.2
7.3
7.2
7.0
7.0
7.1
5.05
4.99
4.91
4.82
4.96
5.09
5.12
5.15
5.25
5.36
5.31
5.26
5.05
4.84
4.97
5.10
5.33
5.09
5.23
5.36
5.06
5.09
5.17
5.06
4.95
4.95
4.96
5.01
5.06
4.92
4.94
4.96
5.02
5.09
5.02
4.96
5.10
5.25
5.24
5.24
5.11
4.98
5.07
5.17
5.19
5.22
5.17
5.12
5.14
5.17
5.24
5.31
5.27
5.23
5.30
5.38
5.37
5.36
5.44
5.53
5.58
5.63
5.39
5.16
5.23
5.30
5.23
5.17
5.20
5.22
5.29
5.36
5.38
5.41
5.33
5.27
5.30
5.33
5.35
5.36
5.22
5.09
5.11
5.13
5.06
4.99
5.02
5.05
5.01
4.98
5.01
5.03
5.09
5.16
5.08
5.00
4.99
4.98
5.02
5.07
5.04
5.01
5.17
5.34
5.31
5.28
5.35
5.21
5.07
5.06
5.07
1810
1815
1820
1825
1830
1835
1840
1845
1850
1855
1860
1865
1870
1875
1880
1885
1895
1905
1910
1915
1925
1935
1945
1950
1955
1960
1965
1970
1975
1985
1990
1995
2000
2005
2010
2015
2020
2025
2030
2035
2040
2045
2050
2055
2060
2065
2070
2075
2080
2085
2090
2095
2100
2105
2110
2115
2120
2125
2130
2135
2140
2145
2150
2155
2160
2165
2170
2175
2180
2185
2190
2195
2200
2205
2210
2215
2220
2225
2230
2235
2240
2245
2250
2255
2260
2265
2270
2275
2280
2285
2290
2295
2300
2305
2310
2315
2320
2325
2330
2335
2340
2345
2350
2355
2360
2365
2375
2380
2385
2395
2400
28.3
28.5
28.6
28.7
28.7
28.7
28.8
28.6
28.4
28.5
28.6
28.5
28.4
28.4
28.5
28.5
28.6
28.5
28.5
28.5
28.6
28.5
28.5
28.6
28.6
28.6
28.7
28.9
28.9
29.1
29.1
29.1
29.1
29.1
29.1
29.2
29.2
29.3
29.3
29.3
29.3
29.2
29.2
29.3
29.5
29.4
29.4
29.5
29.8
29.7
29.7
29.8
29.9
29.8
29.9
29.9
29.9
29.9
29.9
29.8
29.8
29.9
29.9
29.8
29.8
29.9
29.9
29.8
29.8
29.8
29.8
29.8
29.7
29.7
29.7
29.7
29.7
29.8
29.8
29.7
29.5
29.8
30.0
30.0
30.1
30.1
30.2
30.3
30.0
30.3
30.3
30.3
30.2
30.3
30.2
30.1
30.3
304
30.4
30.5
30.5
30.6
30.5
30.6
30.9
31.0
31.1
31.1
31.1
31.2
30.9
7.1
6.9
6.8
6.8
6.8
6.7
6.7
6.9
7.1
7.0
7.0
7.1
7.3
7.2
7.2
7.2
7.2
7.3
7.4
7.3
7.3
7.4
7.5
7.4
7.5
7.5
7.4
7.2
7.2
7.1
7.0
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.0
7.1
7.1
7.2
7.2
7.2
7.0
7.1
7.1
7.0
6.8
6.9
6.9
6.8
6.8
6.8
6.8
6.8
6.8
6.9
6.9
6.9
7.1
6.9
7.0
7.1
7.1
7.0
7.1
7.2
7.2
7.2
7.2
7.2
7.3
7.3
7.4
7.4
7.5
7.3
7.4
7.5
7.7
7.4
7.3
7.2
7.2
7.2
7.1
7.0
7.0
7.0
7.1
7.1
7.2
7.2
7.3
7.4
7.2
7.2
7.1
7.0
7.1
7.0
7.1
7.1
6.8
6.7
6.6
6.6
6.7
6.6
6.9
5.08
4.91
4.74
4.75
4.76
4.72
4.69
4.90
5.12
5.07
5.01
5.17
5.33
5.28
5.22
5.22
5.24
5.36
5.45
5.38
5.35
5.54
5.59
5.48
5.57
5.65
5.47
5.29
5.22
5.11
5.06
5.09
5.11
5.16
5.15
5.13
5.18
5.08
5.05
5.07
5.13
5.23
5.27
5.21
5.02
5.08
5.10
5.01
4.76
4.89
4.86
4.78
4.75
4.81
4.78
4.76
4.84
4.89
4.90
4.94
5.08
4.92
4.98
5.10
5.09
5.00
5.07
5.20
5.27
5.27
5.28
5.30
5.38
5.41
5.47
5.54
5.57
5.43
5.45
5.61
5.86
5.53
5.35
5.28
5.24
5.20
5.12
5.05
5.06
5.05
5.07
5.13
5.23
5.20
5.35
5.45
5.27
5.22
5.13
5.07
5.11
5.07
5.12
5.08
4.79
4.66
4.60
4.61
4.62
4.60
4.93
2405
2410
2415
2420
2425
2430
2435
2440
2445
2450
2455
2460
2465
2470
2475
2480
2490
2500
2505
2510
2520
2530
2540
2545
2550
2555
2560
2565
2570
2580
2585
2590
2595
2600
2605
2610
2615
2620
2625
2630
2635
2640
2645
2650
2655
2660
2665
2670
2675
2680
2685
2690
2695
2700
2705
2710
2715
2720
2725
2730
2735
2740
2745
2750
2755
2760
2765
2770
2775
2780
2785
2790
2795
2800
2805
2810
2815
2820
2825
2830
2835
2840
2845
2850
2855
2860
2865
2870
2875
2880
2885
2890
2895
2900
2905
2910
2915
2920
2925
2930
2935
2940
2945
2950
2955
2960
2970
2975
2980
2990
3000
30.9
30.9
31.0
31.0
31.1
31.0
31.0
31.2
31.1
31.0
31.0
30.9
31.1
31.3
31.4
31.3
31.1
30.9
31.1
31.0
31.2
31.0
31.2
31.0
31.0
31.1
31.0
30.8
31.1
31.6
31.6
31.6
31.5
31.6
31.3
31.4
31.7
31.6
31.4
31.6
31.8
31.7
31.7
31.8
31.8
31.7
32.0
32.0
31.9
31.7
31.9
32.1
32.1
32.0
32.0
32.1
32.1
32.4
32.2
31.9
31.6
31.6
31.9
32.0
32.0
32.0
32.2
32.3
32.3
32.3
32.7
32.8
32.8
32.5
32.5
32.5
32.3
32.2
32.3
32.4
32.5
32.5
32.6
32.6
32.4
32.4
32.8
33.0
33.0
32.5
33.0
33.1
33.1
33.0
32.9
32.9
33.1
33.3
33.0
33.0
33.0
33.0
33.1
33.2
33.3
33.3
33.3
33.0
32.9
32.9
33.4
6.9
6.9
6.9
6.8
6.8
6.9
6.9
6.8
6.9
7.0
7.0
7.2
6.9
6.8
6.7
6.8
7.0
7.2
7.1
7.2
7.0
7.3
7.1
7.3
7.3
7.2
7.4
7.6
7.3
6.9
6.8
6.9
7.0
6.9
7.2
7.1
6.9
7.0
7.1
7.0
6.8
7.0
6.9
6.9
6.9
7.0
6.7
6.7
6.8
7.0
6.8
6.7
6.7
6.8
6.8
6.8
6.7
6.5
6.7
7.0
7.4
7.1
7.0
6.9
7.0
7.0
6.8
6.8
6.8
6.8
6.4
6.3
6.4
6.7
6.6
6.7
6.9
7.0
7.0
6.8
6.7
6.8
6.6
6.7
6.9
7.0
6.5
6.3
6.4
6.9
6.4
6.3
6.4
6.4
6.6
6.5
6.4
6.2
6.5
6.5
6.5
6.5
6.5
6.4
6.3
6.3
6.4
6.6
6.8
6.8
6.4
4.93
4.89
4.85
4.82
4.81
4.87
4.88
4.74
4.91
4.96
5.01
5.19
4.95
4.76
4.69
4.79
4.99
5.27
5.15
5.22
5.05
5.37
5.09
5.43
5.39
5.30
5.47
5.70
5.37
4.87
4.79
4.88
4.97
4.86
5.30
5.15
4.88
4.97
5.17
5.00
4.82
4.98
4.93
4.85
4.85
5.02
4.71
4.67
4.81
5.04
4.83
4.72
4.71
4.81
4.80
4.79
4.71
4.47
4.63
5.05
5.44
5.46
5.06
4.94
4.98
5.06
4.80
4.73
4.77
4.82
4.41
4.25
4.33
4.66
4.62
4.70
4.85
5.01
4.96
4.80
4.68
4.78
4.62
4.70
4.88
4.98
4.52
4.30
4.38
4.87
4.40
4.28
4.34
4.41
4.58
4.51
4.33
4.16
4.45
4.51
4.48
4.52
4.42
4.32
4.27
4.30
4.36
4.60
4.74
4.82
4.33
Page 29 of 30
Report ID: TEXEMC_EN.23555_rev1.docx
Date of Issue: 14-Apr-13
14 APPENDIX F
A
AC
AM
AVRG
cm
dB
dBm
dB(V)
dB(V/m)
dB(A)
DC
EUT
F
GHz
GND
H
HL
Hz
k
kHz
m
MHz
min
mm
ms
s
NA
OATS

QP
RE
RF
rms
Rx
s
T
Tx
V
WB
Abbreviations and acronyms
ampere
alternating current
amplitude modulation
average (detector)
centimeter
decibel
decibel referred to one milliwatt
decibel referred to one microvolt
decibel referred to one microvolt per meter
decibel referred to one microampere
direct current
equipment under test
frequency
gigahertz
ground
height
Hermon laboratories
hertz
kilo
kilohertz
meter
megahertz
minute
millimeter
millisecond
microsecond
not applicable
open area test site
Ohm
quasi-peak
radiated emission
radio frequency
root mean square
receive
second
temperature
transmit
volt
wideband
END OF DOCUMENT
Page 30 of 30
Download