ELECTRICAL TESTING 0839.01 Hermon Laboratories Ltd. Harakevet Industrial Zone, Binyamina 30500, Israel Tel. +972-4-6288001 Fax. +972-4-6288277 E-mail: mail@hermonlabs.com PARTIAL RADIATED EMISSIONS AND RADIATED IMMUNITY TEST REPORT ACCORDING TO: EN 300 386 V1.4.1: 2008 with manufacturer’s deviations: Radiated immunity of 10 V/m in 80 – 1000 MHz range FOR: Texas Instruments (Israel) Cable Broadband Com. TI chip, model TLK110 48p QFP placed on Evaluation board, model Pc405 This report is in conformity with ISO/ IEC 17025. The "A2LA Accredited" symbol endorsement applies only to the tests and calibrations that are listed in the scope of Hermon Laboratories accreditation. The test results relate only to the items tested. This test report shall not be reproduced in any form except in full with the written approval of Hermon Laboratories Ltd. Page 1 of 30 Report ID: TEXEMC_EN.23555_rev1.docx Date of Issue: 14-Apr-13 Report ID: TEXEMC_EN.23555_rev1.docx Date of Issue: 14-Apr-13 Table of contents 1 2 3 4 5 6 6.1 6.2 6.3 6.4 6.5 6.6 7 7.1 8 8.1 9 10 11 12 13 14 Applicant information ..................................................................................................................................................... 3 Equipment under test attributes .................................................................................................................................... 3 Manufacturer information .............................................................................................................................................. 3 Test details .................................................................................................................................................................... 3 Tests summary .............................................................................................................................................................. 4 EUT description ............................................................................................................................................................. 5 General information ....................................................................................................................................................... 5 Ports and lines .............................................................................................................................................................. 5 Support and test equipment .......................................................................................................................................... 5 Test configuration .......................................................................................................................................................... 6 Performance criteria ...................................................................................................................................................... 7 Acceptance criteria ........................................................................................................................................................ 7 Emissions tests ............................................................................................................................................................. 8 Radiated disturbance .................................................................................................................................................... 8 Immunity tests ............................................................................................................................................................. 19 Radiated immunity to radio frequency electromagnetic field ....................................................................................... 19 APPENDIX A Test equipment and ancillaries used for tests ....................................................................................... 25 APPENDIX B Measurement uncertainties................................................................................................................... 26 APPENDIX C Test laboratory description ................................................................................................................... 27 APPENDIX D Specification references ....................................................................................................................... 27 APPENDIX E Test equipment correction factors ......................................................................................................... 28 APPENDIX F Abbreviations and acronyms ................................................................................................................. 30 Page 2 of 30 Report ID: TEXEMC_EN.23555_rev1.docx Date of Issue: 14-Apr-13 1 Applicant information Client name: Texas Instruments (Israel) Cable Broadband Com. Address: 26 Zarchin Street, 43662 Raanana, Israel Telephone: +972 9970 6969 Fax: +972 9970 6500 E-mail: noam.sadan@ti.com Contact name: Mr. Noam Sadan 2 Equipment under test attributes Product name: TI chip, model TLK110 48p QFP placed on Evaluation board, model Pc405 Serial number: 51611 Hardware version: 1 Software release: 1 Receipt date 12/11/2012 3 Manufacturer information Manufacturer name: Texas Instruments (Israel) Cable Broadband Com. Address: 26 Zarchin Street, 43662 Raanana, Israel Telephone: +972 9970 6969 Fax: +972 9970 6500 E-Mail: noam.sadan@ti.com Contact name: Mr. Noam Sadan 4 Test details Project ID: 23555 Location: Hermon Laboratories Ltd. Harakevet Industrial Zone, Binyamina 30500, Israel Test started: 12/11/2012 Test completed: 12/12/2012 Test specification(s): EN 300 386 V1.4.1: 2008 with manufacturer’s deviations: Radiated immunity of 10 V/m in 80 – 1000 MHz range Page 3 of 30 Report ID: TEXEMC_EN.23555_rev1.docx Date of Issue: 14-Apr-13 5 Tests summary Test Status EN 300 386 with manufacturer’s deviations Radiated emissions, Class B Pass preliminary test Radiated immunity to radio frequency electromagnetic field of 10 V/m in 80 – 1000 MHz range Pass preliminary test The test results relate only to the items tested. Name and Title Date Tested by: Mr. V. Dorofeyev, test engineer December 12, 2012 Reviewed by: Mrs. M. Cherniavsky, certification engineer April 14, 2013 Approved by: Mr. M. Nikishin, EMC and radio group manager May 5, 2013 Signature Page 4 of 30 Report ID: TEXEMC_EN.23555_rev1.docx Date of Issue: 14-Apr-13 6 EUT description 6.1 General information The EUT is TI chip (Ethernet device) placed on the evaluation board enclosed in a metal enclosure. The EUT is powered from 5 VDC. 6.2 6.3 Ports and lines Port type Port description Connected from Connected to Qty. Cable type Cable length, m Signal Ethernet EUT External loopback 1 Shielded 2.5 Control USB Laptop USB2MII Board (FPGA Board) 1 Shielded 5 Support and test equipment Description Manufacturer Model number Serial number Laptop Dell D630 E0101139-00 USB2MII Board (FPGA Board) Texas instruments Pc126 42662 Page 5 of 30 Report ID: TEXEMC_EN.23555_rev1.docx Date of Issue: 14-Apr-13 6.4 Test configuration 6.4.1 EUT setup for radiation through cable 6.4.2 EUT setup for radiation from the EUT pins Page 6 of 30 Report ID: TEXEMC_EN.23555_rev1.docx Date of Issue: 14-Apr-13 6.5 Performance criteria 6.5.1 General performance criteria of EN 300 386, Section 10 6.5.1.1 Performance criterion A The equipment shall continue to operate as intended. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer when the equipment is used as intended. The performance level may be replaced by a permissible loss of performance. If the manufacturer does not specify the minimum performance level or the permissible performance loss, then either of these may be derived from the product description and documentation, and by what the user may reasonably expect from the equipment if used as intended. 6.5.2 Specific performance criteria of EN 300 386, Section 11 (Switching equipment specific requirements) 6.5.2.1 11.3.1 Digital ports Performance criterion A: During the sweep: the established connections shall be maintained throughout testing and the transfer of information shall be within the limits of the manufacturer’s specification; loss of frame alignment or loss of synchronization is not allowed during each individual exposure. For selected frequencies : it shall be possible to establish a connection between two ports; it shall be possible to clear a connection in a controlled manner. 6.5.3 Specific performance criteria of EN 300 386, Section 12 (Transmission equipment specific requirements) 6.5.3.1 12.3.1 Digital signal ports Performance criterion A: The performance of the equipment shall be verified by measuring the additional errors induced due to the application of any electromagnetic phenomena. During the test sweep the established connection shall be maintained throughout the testing and the transfer of information shall be without any reproducible bit errors. If degradation in performance is observed and the system is adaptive i.e. has capability to automatically re-train in the presence of an interfering signal, then for conducted immunity tests only the following procedure shall be followed: - For each range of interfering frequencies, where degradation in performance is observed, three frequencies (beginning, middle and end) shall be identified. - At each of the frequencies identified in step 1, the interfering signal shall be turned and the system allowed to re-train. If the system is able to re-train and then function with respect to the performance criteria A then the system performance is considered acceptable. - The frequencies identified in step 1 shall be recorded in the test report. 6.6 Acceptance criteria Data packets shall be transmitted from TI chip, using its internal PRBS generator to an external loopback, which returns the packets to TI chip to compare to transmitted packets. No data packets error is allowed during the test. Page 7 of 30 Report ID: TEXEMC_EN.23555_rev1.docx Date of Issue: 14-Apr-13 Test specification: Section 6 Class B, Radiated disturbance Test procedure: Test mode: Date(s): Temperature: 22 ºC Remarks: EN 55022, Section 10 Compliance 12/12/2012 Air Pressure: 1018 hPa Verdict: Relative Humidity: 45 % PASS Power Supply: 5 VDC 7 Emissions tests 7.1 Radiated disturbance 7.1.1 General This test was performed to measure radiated disturbance from the EUT enclosure. The specification test limits are given in Table 7.1.1. Table 7.1.1 Radiated disturbance limits Frequency, MHz Class B limit, dB(V/m) Peak Quasi-peak Average @3 m @3 m @10 m @3 m 30 - 230 ––– 30.0 40.5* ––– 230 - 1000 ––– 37.0 47.5* ––– 1000 – 3000 70 ––– ––– 50 3000 - 6000 74 ––– ––– 54 * The limit for test distance other than specified was calculated using the inverse linear distance extrapolation factor as follows: LimS2 = LimS1 + 20 log (S1/S2), where S1 and S2 – standard defined and test distance respectively in meters. 7.1.2 Test procedure 7.1.2.1 The EUT was set up as shown in Figure 7.1.1 and the associated photographs, energized and the EUT performance was checked. 7.1.2.2 The preliminary measurements were performed in the anechoic chamber at 3 m test distance. The specified frequency range was investigated with the antenna connected to the EMI receiver. To find maximum radiation the turntable was rotated 3600 and the measuring antenna height was swept from 1 to 4 m in both, vertical and horizontal polarizations. 7.1.2.3 The worst test results for radiation through cable with respect to the limits were recorded in Table 7.1.2 and shown in the associated plots. 7.1.2.4 The test was repeated for evaluation of radiation from pins, the test results are shown in the associated plots. Page 8 of 30 Report ID: TEXEMC_EN.23555_rev1.docx Date of Issue: 14-Apr-13 Test specification: Section 6 Class B, Radiated disturbance Test procedure: Test mode: Date(s): Temperature: 22 ºC Remarks: EN 55022, Section 10 Compliance 12/12/2012 Air Pressure: 1018 hPa Verdict: Relative Humidity: 45 % PASS Power Supply: 5 VDC Figure 7.1.1 Setup for radiated emissions measurements in anechoic chamber, table-top EUT 1.5 m Anechoic chamber Test antenna RF absorbing material Ferrites Test distance EUT Test antenna Flush mounted turn table Auxilliary equipment 1.0m 0.80m Wooden table Ground plane Power supply PC EMI receiver Page 9 of 30 Report ID: TEXEMC_EN.23555_rev1.docx Date of Issue: 14-Apr-13 Test specification: Section 6 Class B, Radiated disturbance Test procedure: Test mode: Date(s): Temperature: 22 ºC Remarks: EN 55022, Section 10 Compliance 12/12/2012 Air Pressure: 1018 hPa Verdict: Relative Humidity: 45 % PASS Power Supply: 5 VDC Photograph 7.1.1 Setup for preliminary radiated disturbance measurements, general view, EUT radiation through cable Photograph 7.1.2 Setup for preliminary radiated disturbance measurements, general view, EUT radiation through cable Page 10 of 30 Report ID: TEXEMC_EN.23555_rev1.docx Date of Issue: 14-Apr-13 Test specification: Section 6 Class B, Radiated disturbance Test procedure: Test mode: Date(s): Temperature: 22 ºC Remarks: EN 55022, Section 10 Compliance 12/12/2012 Air Pressure: 1018 hPa Verdict: Relative Humidity: 45 % PASS Power Supply: 5 VDC Photograph 7.1.3 Setup for radiated disturbance measurements, EUT radiation through cable Photograph 7.1.4 Setup for radiated disturbance measurements, EUT close view Page 11 of 30 Report ID: TEXEMC_EN.23555_rev1.docx Date of Issue: 14-Apr-13 Test specification: Section 6 Class B, Radiated disturbance Test procedure: Test mode: Date(s): Temperature: 22 ºC Remarks: EN 55022, Section 10 Compliance 12/12/2012 Air Pressure: 1018 hPa PASS Verdict: Relative Humidity: 45 % Power Supply: 5 VDC Table 7.1.2 Radiated disturbance test results EUT SET UP: TEST SITE: TEST DISTANCE: DETECTORS USED: FREQUENCY RANGE: RESOLUTION BANDWIDTH: TLK110 48p QFP radiation through cable Quasi-peak Peak Frequency, Measured Limit, emission, emission, MHz dB(V/m) dB(V/m) dB(V/m) Note* 122.83 35.54 40.5 Note* 32.00 37.00 40.5 *Note:Quasi-peak emission was not measured TABLE-TOP Fully anecoic chamber 3m PEAK / QUASI-PEAK 30 MHz – 1000 MHz 120 kHz Margin, to peak dB* -4.96 -3.50 Antenna polarization Antenna height, m Turn-table position**, degrees Verdict Vertical Vertical Note* Note* Note* Note* Pass* DETECTORS USED: PEAK / AVERAGE FREQUENCY RANGE: 1000 MHz – 2900 MHz RESOLUTION BANDWIDTH: 1000 kHz TEST SITE: Fully anecoic chamber TEST DISTANCE: 3m TLK110 48p QFP radiation through cable Peak Average Frequency, Antenna Turn-table Measured Limit, Margin, Measured Limit, Margin, Antenna height, position**, Verdict emission, emission, polarization MHz m degrees dB(V/m) dB(V/m) dB* dB(V/m) dB(V/m) dB* No emissions were found Pass Reference numbers of test equipment used HL 2432 HL 2697 HL 4150 HL 4347 HL 4349 Full description is given in Appendix A. Page 12 of 30 Report ID: TEXEMC_EN.23555_rev1.docx Date of Issue: 14-Apr-13 Test specification: Section 6 Class B, Radiated disturbance Test procedure: Test mode: Date(s): Temperature: 22 ºC Remarks: EN 55022, Section 10 Compliance 12/12/2012 Air Pressure: 1018 hPa Verdict: Relative Humidity: 45 % PASS Power Supply: 5 VDC Plot 7.1.1 Radiated disturbance measurements in 30 - 1000 MHz range, vertical antenna polarization TEST SITE: TEST DISTANCE: Fully anecoic chamber 3m TLK110 48p QFP radiation through cable Plot 7.1.2 Radiated disturbance measurements in 30 - 1000 MHz range, horizontal antenna polarization TEST SITE: TEST DISTANCE: Fully anecoic chamber 3m TLK110 48p QFP radiation through cable Page 13 of 30 Report ID: TEXEMC_EN.23555_rev1.docx Date of Issue: 14-Apr-13 Test specification: Section 6 Class B, Radiated disturbance Test procedure: Test mode: Date(s): Temperature: 22 ºC Remarks: EN 55022, Section 10 Compliance 12/12/2012 Air Pressure: 1018 hPa Verdict: Relative Humidity: 45 % PASS Power Supply: 5 VDC Plot 7.1.3 Radiated disturbance measurements in 1000 – 2900 MHz range, vertical antenna polarization TEST SITE: TEST DISTANCE: Fully anecoic chamber 3m TLK110 48p QFP radiation through cable Plot 7.1.4 Radiated disturbance measurements in 1000 – 2900 MHz range, horizontal antenna polarization TEST SITE: TEST DISTANCE: Fully anecoic chamber 3m TLK110 48p QFP radiation through cable Page 14 of 30 Report ID: TEXEMC_EN.23555_rev1.docx Date of Issue: 14-Apr-13 Test specification: Section 6 Class B, Radiated disturbance Test procedure: Test mode: Date(s): Temperature: 22 ºC Remarks: EN 55022, Section 10 Compliance 12/12/2012 Air Pressure: 1018 hPa Verdict: Relative Humidity: 45 % PASS Power Supply: 5 VDC Photograph 7.1.5 Setup for radiated disturbance measurements, radiation from EUT pins Photograph 7.1.6 Setup for radiated disturbance measurements, radiation from EUT pins Page 15 of 30 Report ID: TEXEMC_EN.23555_rev1.docx Date of Issue: 14-Apr-13 Test specification: Section 6 Class B, Radiated disturbance Test procedure: Test mode: Date(s): Temperature: 22 ºC Remarks: EN 55022, Section 10 Compliance 12/12/2012 Air Pressure: 1018 hPa Verdict: Relative Humidity: 45 % PASS Power Supply: 5 VDC Photograph 7.1.7 Setup for radiated disturbance measurements, radiation from EUT pins Page 16 of 30 Report ID: TEXEMC_EN.23555_rev1.docx Date of Issue: 14-Apr-13 Test specification: Section 6 Class B, Radiated disturbance Test procedure: Test mode: Date(s): Temperature: 22 ºC Remarks: EN 55022, Section 10 Compliance 12/12/2012 Air Pressure: 1018 hPa Verdict: Relative Humidity: 45 % PASS Power Supply: 5 VDC Plot 7.1.5 Radiated disturbance measurements in 30 - 1000 MHz range, vertical antenna polarization TEST SITE: TEST DISTANCE: Fully anecoic chamber 3m TLK110 48p QFP radiation from EUT pins Note: To find the highest emission the measuring antenna height was swept from 1 to 1.8 m (turntable was not rotated) Plot 7.1.6 Radiated disturbance measurements in 30 - 1000 MHz range, horizontal antenna polarization TEST SITE: TEST DISTANCE: Fully anecoic chamber 3m TLK110 48p QFP radiation from EUT pins Note: To find the highest emission the measuring antenna height was swept from 1 to 1.8 m (turntable was not rotated) Page 17 of 30 Report ID: TEXEMC_EN.23555_rev1.docx Date of Issue: 14-Apr-13 Test specification: Section 6 Class B, Radiated disturbance Test procedure: Test mode: Date(s): Temperature: 22 ºC Remarks: EN 55022, Section 10 Compliance 12/12/2012 Air Pressure: 1018 hPa Verdict: Relative Humidity: 45 % PASS Power Supply: 5 VDC Plot 7.1.7 Radiated disturbance measurements in 1000 – 2900 MHz range, vertical antenna polarization TEST SITE: TEST DISTANCE: Fully anecoic chamber 3m TLK110 48p QFP radiation from EUT pins Note: To find the highest emission the measuring antenna height was swept from 1 to 1.8 m (turntable was not rotated) Plot 7.1.8 Radiated disturbance measurements in 1000 – 2900 MHz range, horizontal antenna polarization TEST SITE: TEST DISTANCE: Fully anecoic chamber 3m TLK110 48p QFP radiation from EUT pins Note: To find the highest emission the measuring antenna height was swept from 1 to 1.8 m (turntable was not rotated) Page 18 of 30 Report ID: TEXEMC_EN.23555_rev1.docx Date of Issue: 14-Apr-13 Test specification: Radiated immunity to radio frequency electromagnetic field Test procedure: Test mode: Date(s): Temperature: 23 ºC Remarks: EN 61000-4-3; EN 55024, Section 4.2.3.1 Evaluation Verdict: 12/12/2012 Air Pressure: 1018 hPa Relative Humidity: 39 % PASS Power Supply: 5 VDC 8 Immunity tests 8.1 Radiated immunity to radio frequency electromagnetic field 8.1.1 General This test was performed to verify the EUT immunity to radiated radio frequency electromagnetic field. The radiated RF electromagnetic field levels, performance criterion and test results are referred to in Table 8.1.1. 8.1.2 Test procedure 8.1.2.1 The EUT was set up as shown in Figure 8.1.1 and the associated photographs, energized and the EUT performance was checked. 8.1.2.2 The electric field generating antenna was installed facing the EUT front panel at the specified distance. 8.1.2.3 The test setup was adjusted to produce the required field strength level. The field strength was monitored by the isotropic field probe, which was placed near the EUT. 8.1.2.4 The signal frequency was scanned throughout the frequency range. 8.1.2.5 The test was performed with antenna/s in both vertical and horizontal polarizations. 8.1.2.6 The test was repeated at selected frequencies. 8.1.2.7 The EUT operation was monitored throughout the test for any malfunction or degradation and its performance was recorded. 8.1.2.8 Upon this the test was completed. Page 19 of 30 Report ID: TEXEMC_EN.23555_rev1.docx Date of Issue: 14-Apr-13 Test specification: Radiated immunity to radio frequency electromagnetic field Test procedure: Test mode: Date(s): Temperature: 23 ºC Remarks: EN 61000-4-3; EN 55024, Section 4.2.3.1 Evaluation Verdict: 12/12/2012 Air Pressure: 1018 hPa Relative Humidity: 39 % PASS Power Supply: 5 VDC Figure 8.1.1 Setup for radiated immunity to RF electromagnetic field test, table-top EUT Test chamber Antenna mast Test distance E-field probe Transmit antenna 1meter of the EUT cable aligned with front side 0.80m Wooden table 1.55 m EUT Bulkhead RF connector Turn table Auxilliary equipment E-field monitor RF signal generator RF Power amplifier Directional coupler Optical link Power supply Personal computer Power Meter Page 20 of 30 Report ID: TEXEMC_EN.23555_rev1.docx Date of Issue: 14-Apr-13 Test specification: Radiated immunity to radio frequency electromagnetic field Test procedure: Test mode: Date(s): Temperature: 23 ºC Remarks: EN 61000-4-3; EN 55024, Section 4.2.3.1 Evaluation Verdict: 12/12/2012 Air Pressure: 1018 hPa Relative Humidity: 39 % PASS Power Supply: 5 VDC Photograph 8.1.1 Setup for radiated immunity to RF electromagnetic field test, general view, EUT radiation through cable Photograph 8.1.2 Setup for radiated immunity to RF electromagnetic field test, EUT close view, EUT radiation through cable Page 21 of 30 Report ID: TEXEMC_EN.23555_rev1.docx Date of Issue: 14-Apr-13 Test specification: Radiated immunity to radio frequency electromagnetic field Test procedure: Test mode: Date(s): Temperature: 23 ºC Remarks: EN 61000-4-3; EN 55024, Section 4.2.3.1 Evaluation Verdict: 12/12/2012 Air Pressure: 1018 hPa Relative Humidity: 39 % PASS Power Supply: 5 VDC Photograph 8.1.3 Setup for radiated immunity to RF electromagnetic field test, general view, radiation from EUT pins Photograph 8.1.4 Setup for radiated immunity to RF electromagnetic field test, general view, radiation from EUT pins Page 22 of 30 Report ID: TEXEMC_EN.23555_rev1.docx Date of Issue: 14-Apr-13 Test specification: Radiated immunity to radio frequency electromagnetic field Test procedure: Test mode: Date(s): Temperature: 23 ºC Remarks: EN 61000-4-3; EN 55024, Section 4.2.3.1 Evaluation Verdict: 12/12/2012 Air Pressure: 1018 hPa Relative Humidity: 39 % PASS Power Supply: 5 VDC Photograph 8.1.5 Setup for radiated immunity to RF electromagnetic field test, EUT close view, radiation from EUT pins Page 23 of 30 Report ID: TEXEMC_EN.23555_rev1.docx Date of Issue: 14-Apr-13 Test specification: Radiated immunity to radio frequency electromagnetic field Test procedure: Test mode: Date(s): Temperature: 23 ºC Remarks: EN 61000-4-3; EN 55024, Section 4.2.3.1 Evaluation Verdict: 12/12/2012 Air Pressure: 1018 hPa Relative Humidity: 39 % PASS Power Supply: 5 VDC Table 8.1.1 Radiated immunity to RF electromagnetic field test results TLK110 48p QFP radiation through cable EUT SET UP: PERFORMANCE CRITERIA: TEST SITE: ANTENNA TO EUT DISTANCE: FREQUENCY RANGE: MODULATION: DWELL TIME: FREQUENCY STEP: EUT orientation* Antenna polarization TABLE-TOP A FULLY ANECHOIC CHAMBER 2.4 m 80 – 1000 MHz 80% AM with 1 kHz 2.8 s 1 % of current frequency Field strength**, Vrms/m Vertical 10*** Horizontal * - 0 = antenna installed facing the EUT front panel. **- Field strength measured prior to modulation. *** - The standard requirement is 3 Vrms/m. The found threshold was 8 Vrms/m. 0 EUT performance description during the test Verdict NP At 89.49 MHz and 97.61 MHz the errors appeared Pass*** TLK110 48p QFP radiation from EUT pins EUT SET UP: PERFORMANCE CRITERIA: TEST SITE: ANTENNA TO EUT DISTANCE: FREQUENCY RANGE: MODULATION: DWELL TIME: FREQUENCY STEP: EUT orientation* Antenna polarization Field strength**, Vrms/m EUT performance description during the test 10*** At 81, 130, 184, 226, 350, 489, 707, 960 MHz the errors appeared; the threshold 5 V at 707 MHz At 81, 115, 130, 160, 197, 525, 551, 743 MHz the errors appeared Vertical 0 TABLE-TOP A MILITARY STD ANECHOIC CHAMBER 2.0 m 80 – 1000 MHz 80% AM with 1 kHz 2.8 s 1 % of current frequency Horizontal Verdict Pass*** Tested * - 0 = antenna installed facing the EUT front panel. **- Field strength measured prior to modulation. *** - The standard requirement is 3 Vrms/m. ***The 5 Vrms/m threshold was defined for 707 MHz only. Reference numbers of test equipment used HL 0317 HL 0613 HL 0659 HL 2109 HL 2376 HL 2432 Full description is given in Appendix A. HL 0674 HL 2697 HL 1097 HL 2783 HL 1544 HL 2788 HL 1629 HL 3158 HL 2078 HL 3508 Page 24 of 30 Report ID: TEXEMC_EN.23555_rev1.docx Date of Issue: 14-Apr-13 9 APPENDIX A HL No 0317 0613 0659 0674 Test equipment and ancillaries used for tests Description Power Sensor, 30 MHz - 18 GHz, -70 to 20 dBm Sensor Electric Field 10 kHz-1.0 GHz, 1-300 V/m (probe) Amplifier 1 to 4 GHz, 55 W 1544 1629 Coupler Directional, high power 80 - 1000 MHz, 1500 W Attenuator, 50 Ohm, 5 W, DC to 8 GHz, 20 dB Cable RF, N/N-type, 3.2 m Isotropic Field Monitor 2078 Isotropic Field Probe 80 MHz - 40 GHz 2109 Anechoic Chamber 6(L) x 5.5(W) x 2.95(H) m Coupler coaxial bi-directional 1 - 4 GHz, 20 dB Antenna, Double-Ridged Waveguide Horn 1-18 GHz Antenna, 30 MHz - 3.0 GHz 1097 2376 2432 2697 2783 Power Meter, RF, IEEE-488, 100 kHz 100 GHz, -70 to +37 dBm 2788 3158 Horn Antenna, 0.5 to 4 GHz Amplifier, 80 to 1000 MHz, 500 W 3508 MIL STD Anechoic Chamber 6.0(L) x 4.8(W) x 2.9(H) m Preamplifier, 0.1 to 18 GHz, Gain 25 dB, N-type(f) in, N-type(m) out. Low Loss Armored Test Cable, DC - 18 GHz, 2.0 m, N type-M/N type-M Low Loss Armored Test Cable, DC - 18 GHz, 4.5 m, N type-M/N type-M 4150 4347 4349 Manufacturer 51072 26163 Last Cal./ Check 01-Jan-13 FP2000 18677 07-Dec-12 07-Dec-13 AS010455/55B C3908 971386 03-Jul-12 03-Jul-13 5843 01-Jan-13 01-Jan-14 Midwest Microwave Alpha Wire Amplifier Research Amplifier Research Hermon Laboratories Narda 0793-20NN-07 RG-213/U FM2000 1097 10-Oct-12 10-Oct-13 1544 23308 19-Jul-12 07-Dec-12 19-Jul-13 07-Dec-13 FP2080 302541 10-Feb-13 10-Feb-14 AC-2 2109 07-Nov-12 07-Nov-13 3022 50076 21-Jun-12 21-Jun-13 EMC Test Systems Sunol Sciences. Corp. Pleasanton, California USA Boonton Electronics Corp. GTE Sylvania Amplifier Research ETS Lindgren 3115 00027177 07-Dec-12 07-Dec-13 JB3 A022805 20-May-12 20-May-14 4220 156602BK 02-Jan-13 02-Jan-14 AN-10E 500W100 0A RFD-F/A100 87405C 78004 032960 30-Jul-10 03-Apr-13 30-Jul-13 03-Apr-14 4311 30-Oct-12 30-Oct-13 MY470105 91 12025103 001 12025102 001 18-Jun-12 18-Jun-13 06-Mar-13 06-Mar-14 01-Jan-13 01-Jan-14 Boonton Electronics Corp. Amplifier Research Milmega WERLATONE Agilent Technologies MegaPhase MegaPhase Model NC29N1N1-79 NC29N1N1-177 Ser. No. Due Cal./ Check 01-Jan-14 Page 25 of 30 Report ID: TEXEMC_EN.23555_rev1.docx Date of Issue: 14-Apr-13 10 APPENDIX B Measurement uncertainties Expanded uncertainty at 95% confidence in Hermon Labs EMC measurements Test description Radiated emissions at 3 m measuring distance Horizontal polarization Vertical polarization Radiated immunity AR FP2000 E-field probe AR FP2080 E-field probe Expanded uncertainty Biconilog antenna: 5.3 dB Biconical antenna: 5.0 dB Log periodic antenna: 5.3 dB Double ridged horn antenna: 5.3 dB Biconilog antenna: 6.0 dB Biconical antenna: 5.7 dB Log periodic antenna: 6.0 dB Double ridged horn antenna: 6.0 dB 10 kHz to 250 MHz: 1.9 dB; 250 MHz to 1 GHz: 2.1 dB 80 MHz to 26 GHz: 2.7 dB; 26 GHz to 40 GHz: 4.0 dB Hermon Laboratories is accredited by A2LA for calibration according to present requirements of ISO/IEC 17025 and NCSL Z540-1. The accreditation is granted to perform calibration of parameters that are listed in the Scope of Hermon Laboratories Accreditation. Hermon Laboratories calibrates its reference and transfer standards by calibration laboratories accredited to ISO/IEC 17025 by a mutually recognized Accreditation Body or by a recognized national metrology institute. All reference and transfer standards used in the calibration system are traceable to national or international standards. In-house calibration of all test and measurement equipment is performed on a regular basis according to Hermon Laboratories calibration procedures, manufacturer calibration/verification procedures or procedures defined in the relevant standards. The Hermon Laboratories test and measurement equipment is calibrated within the tolerances specified by the manufacturers and/or by the relevant standards. Page 26 of 30 Report ID: TEXEMC_EN.23555_rev1.docx Date of Issue: 14-Apr-13 11 APPENDIX C Test laboratory description Tests were performed at Hermon Laboratories Ltd., which is a fully independent, private, EMC, safety, environmental and telecommunication testing facility. Hermon Laboratories is listed by the Federal Communications Commission (USA) for all parts of Code of Federal Regulations 47 (CFR 47), Registration Numbers 90624 for OATS and 90623 for the anechoic chamber; by Industry Canada for electromagnetic emissions (file numbers IC 2186A-1 for OATS and IC 2186A-2 for anechoic chamber), certified by VCCI, Japan (the registration numbers are R-808 for OATS, R-1082 for semi anechoic chamber, G-27 for full-anechoic chamber, C-845 for conducted emissions (mains ports) site, T-1606 for conducted emissions (telecommunication ports) site), has a status of a Telefication - Listed Testing Laboratory, Certificate No. L138/00. The laboratory is accredited by American Association for Laboratory Accreditation (USA) according to ISO/IEC 17025 for electromagnetic compatibility, product safety, telecommunications testing and environmental simulation (for exact scope please refer to Certificate No. 839.01). Address: Telephone: Fax: e-mail: website: P.O. Box 23, Binyamina 30500, Israel. +972 4628 8001 +972 4628 8277 mail@hermonlabs.com www.hermonlabs.com Person for contact: Mr. Alex Usoskin, CEO. 12 APPENDIX D Specification references EN 300 386 V1.4.1: 2008 Electromagnetic compatibility and Radio spectrum Matters (ERM). Telecommunication network equipment. ElectroMagnetic Compatibility (EMC) requirements EN 55022: 2010 Limits and methods of measurement of interference characteristics of information technology equipment CISPR 16-1-1: 2006 Specification for radio disturbance and immunity measuring apparatus and methods. Part 1-1: Radio disturbance and immunity measuring apparatus – Measuring apparatus EN 61000-4-3: 2006+A1(08)+A2(10) Electromagnetic compatibility (EMC). Part 4: testing and measurement techniques. Section 3: Radiated, radio frequency, electromagnetic field immunity test Page 27 of 30 Report ID: TEXEMC_EN.23555_rev1.docx Date of Issue: 14-Apr-13 13 APPENDIX E Test equipment correction factors Antenna factor Double-ridged guide horn antenna Model 3115, serial number: 00027177, HL 2432 Frequency, MHz 1000.0 1500.0 2000.0 2500.0 3000.0 3500.0 4000.0 4500.0 5000.0 5500.0 6000.0 6500.0 7000.0 7500.0 8000.0 8500.0 9000.0 9500.0 10000.0 10500.0 11000.0 11500.0 12000.0 12500.0 13000.0 13500.0 14000.0 14500.0 15000.0 15500.0 16000.0 16500.0 17000.0 17500.0 18000.0 Antenna factor. dB(1/m) 24.7 25.7 27.8 28.9 30.7 31.8 33.0 32.8 34.2 34.9 35.2 35.4 36.3 37.3 37.5 38.0 38.3 38.3 38.7 38.7 38.9 39.5 39.5 39.4 40.5 40.8 41.5 41.3 40.2 38.7 38.5 39.8 41.9 45.8 49.1 Antenna factor in dB(1/m) is to be added to receiver meter reading in dB(V) to convert it into field strength in dB(V/m). Page 28 of 30 Report ID: TEXEMC_EN.23555_rev1.docx Date of Issue: 14-Apr-13 Antenna calibration Sunol Sciences Inc., model JB3, serial number A022805, HL 2697 Frequency, MHz ACF, dB Gain, dBi Num gain Frequency, MHz ACF, dB Gain, dBi Num gain Frequency, MHz ACF, dB Gain, dBi Num gain Frequency, MHz ACF, dB Gain, dBi Num gain Frequency, MHz ACF, dB Gain, dBi Num gain 30 35 40 45 45 50 55 60 65 70 75 80 85 90 95 100 110 120 125 130 140 150 160 165 170 175 180 185 190 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 435 440 445 450 455 460 465 470 475 480 485 490 495 500 505 510 515 520 525 530 535 540 545 550 555 560 565 570 575 580 590 595 600 610 615 22.2 18.5 14.7 11.3 11.3 8.9 7.9 7.8 8.5 9.0 8.8 8.4 8.0 8.2 9.2 10.6 12.6 13.9 14.2 14.2 13.4 12.9 12.7 12.5 12.2 11.8 11.6 11.5 11.6 13.1 12.0 11.0 11.3 11.6 11.7 11.9 12.1 12.3 12.3 12.3 12.5 12.7 13.2 13.7 13.7 13.7 13.7 13.7 13.8 13.9 14.0 14.1 14.3 14.4 14.5 14.6 14.7 14.7 14.9 15.1 15.3 15.6 15.5 15.5 15.6 15.7 15.7 15.7 15.9 16.0 16.3 16.5 16.5 16.6 16.6 16.7 16.9 17.1 17.2 17.2 17.3 17.4 17.5 17.6 17.7 17.9 18.0 18.2 18.0 17.9 17.9 18.0 18.1 18.2 18.2 18.3 18.3 18.4 18.4 18.4 18.6 18.8 18.9 19.0 19.1 19.1 19.1 19.0 19.0 19.1 19.4 -22.5 -17.4 -12.5 -8.1 -8.1 -4.7 -2.8 -2.1 -2.0 -1.9 -1.1 -0.2 0.8 1.1 0.5 -0.4 -1.6 -2.1 -2.0 -1.7 -0.3 0.8 1.6 2.0 2.6 3.3 3.7 4.0 4.2 3.2 4.4 5.6 5.6 5.5 5.5 5.5 5.5 5.5 5.7 5.9 5.9 5.8 5.5 5.2 5.3 5.4 5.6 5.7 5.8 5.8 5.9 5.9 5.9 5.9 5.9 5.9 6.0 6.2 6.1 6.0 5.9 5.8 5.9 6.0 6.1 6.1 6.2 6.3 6.3 6.2 6.1 6.0 6.0 6.1 6.1 6.2 6.1 5.9 6.0 6.0 6.1 6.1 6.1 6.1 6.0 5.9 5.9 5.8 6.0 6.3 6.3 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.5 6.6 6.5 6.4 6.4 6.3 6.3 6.4 6.6 6.6 6.7 6.8 6.5 0.01 0.02 0.06 0.16 0.16 0.34 0.52 0.62 0.63 0.64 0.78 0.97 1.20 1.29 1.13 0.92 0.70 0.62 0.63 0.68 0.94 1.21 1.44 1.59 1.83 2.13 2.36 2.54 2.61 2.07 2.76 3.66 3.59 3.52 3.55 3.57 3.56 3.54 3.71 3.88 3.85 3.83 3.54 3.27 3.39 3.50 3.61 3.72 3.77 3.81 3.85 3.88 3.89 3.90 3.92 3.93 4.02 4.12 4.06 3.99 3.88 3.78 3.89 4.01 4.03 4.05 4.15 4.25 4.22 4.18 4.07 3.96 4.00 4.03 4.10 4.16 4.05 3.93 3.97 4.00 4.04 4.07 4.05 4.04 3.99 3.93 3.88 3.82 4.02 4.23 4.29 4.36 4.34 4.32 4.36 4.39 4.41 4.41 4.47 4.53 4.45 4.37 4.33 4.28 4.31 4.33 4.52 4.62 4.72 4.76 4.51 620 625 630 635 640 645 650 655 660 665 670 675 680 685 690 695 705 715 720 725 735 745 755 760 765 770 775 780 785 795 800 805 810 815 820 825 830 835 840 845 850 855 860 865 870 875 880 885 890 895 900 905 910 915 920 925 930 935 940 945 950 955 960 965 970 975 980 985 990 995 1000 1005 1010 1015 1020 1025 1030 1035 1040 1045 1050 1055 1060 1065 1070 1075 1080 1085 1090 1095 1100 1105 1110 1115 1120 1125 1130 1135 1140 1145 1150 1155 1160 1165 1170 1175 1185 1190 1195 1205 1210 19.7 19.7 19.6 19.7 19.9 19.9 19.9 19.9 19.9 19.9 20.0 20.1 20.1 20.1 20.1 20.2 20.4 20.5 20.5 20.6 20.9 21.0 21.0 21.0 21.1 21.3 21.3 21.3 21.3 21.4 21.5 21.6 21.7 21.7 21.7 21.7 21.7 21.8 21.9 21.9 21.9 22.0 22.1 22.0 21.9 22.0 22.1 22.1 22.1 22.2 22.2 22.3 22.3 22.4 22.6 22.7 22.8 22.8 22.8 22.8 22.9 23.0 23.1 23.1 23.2 23.3 23.5 23.5 23.6 23.6 23.7 23.7 23.7 23.7 23.8 23.8 23.7 23.7 23.6 23.7 23.7 23.7 23.6 23.7 23.8 23.8 23.9 24.0 24.0 24.1 24.2 24.3 24.3 24.3 24.4 24.3 24.3 24.4 24.5 24.6 24.7 24.7 24.7 24.7 24.7 24.8 24.8 24.7 24.7 24.08 24.8 6.3 6.5 6.6 6.5 6.4 6.5 6.5 6.6 6.7 6.7 6.7 6.7 6.7 6.8 6.9 6.8 6.8 6.8 6.9 6.8 6.7 6.6 6.8 6.8 6.8 6.7 6.7 6.7 6.8 6.8 6.8 6.7 6.7 6.7 6.8 6.8 6.9 6.8 6.8 6.8 6.9 6.8 6.8 6.9 7.1 7.1 7.0 7.0 7.0 7.1 7.1 7.1 7.0 7.0 6.9 6.9 6.8 6.8 6.9 6.9 6.9 6.8 6.8 6.7 6.7 6.6 6.6 6.6 6.5 6.5 6.5 6.5 6.6 6.6 6.6 6.6 6.7 6.8 6.9 6.9 6.9 7.0 7.1 7.0 7.0 7.0 7.0 7.0 6.9 6.9 6.8 6.8 6.8 6.8 6.8 6.9 7.0 6.9 6.8 6.8 6.7 6.8 6.8 6.8 6.8 6.8 6.9 7.0 7.0 7.1 7.1 4.27 4.42 4.57 4.48 4.40 4.45 4.51 4.60 4.69 4.70 4.71 4.71 4.71 4.79 4.88 4.82 4.75 4.80 4.85 4.81 4.65 4.59 4.74 4.83 4.73 4.64 4.68 4.72 4.77 4.79 4.77 4.71 4.65 4.72 4.80 4.82 4.85 4.82 4.80 4.83 4.86 4.80 4.74 4.92 5.11 5.08 5.05 5.06 5.06 5.09 5.12 5.09 5.05 4.99 4.92 4.85 4.77 4.83 4.89 4.87 4.85 4.81 4.77 4.73 4.69 4.62 4.54 4.52 4.50 4.48 4.46 4.51 4.57 4.55 4.54 4.62 4.70 4.81 4.92 4.91 4.91 5.01 5.11 5.06 5.01 5.01 5.01 4.96 4.91 4.86 4.82 4.80 4.78 4.79 4.80 4.90 5.00 4.90 4.81 4.76 4.71 4.76 4.80 4.81 4.81 4.84 4.92 4.99 5.02 5.08 5.11 1215 1220 1225 1230 1235 1240 1245 1250 1255 1260 1265 1270 1275 1280 1285 1290 1300 1310 1315 1320 1330 1340 1350 1355 1360 1365 1370 1375 1380 1390 1395 1400 1405 1410 1415 1420 1425 1430 1435 1440 1445 1450 1455 1460 1465 1470 1475 1480 1485 1490 1495 1500 1505 1510 1515 1520 1525 1530 1535 1540 1545 1550 1555 1560 1565 1570 1575 1580 1585 1590 1595 1600 1605 1610 1615 1620 1625 1630 1635 1640 1645 1650 1655 1660 1665 1670 1675 1680 1685 1690 1695 1700 1705 1710 1715 1720 1725 1730 1735 1740 1745 1750 1755 1760 1765 1770 1780 1785 1790 1800 1805 24.9 24.9 25.1 25.2 25.1 25.0 25.0 25.0 25.0 24.9 25.0 25.1 25.3 25.5 25.4 25.3 25.2 25.5 25.4 25.3 25.6 25.7 25.7 25.8 25.9 26.0 26.0 26.0 26.0 26.1 26.2 26.2 26.1 26.1 26.2 26.3 26.2 26.1 26.1 26.2 26.3 26.5 26.4 26.4 26.4 26.4 26.4 26.5 26.5 26.5 26.5 26.5 26.5 26.6 26.6 26.5 26.6 26.6 26.6 26.5 26.5 26.5 26.7 26.9 26.9 26.9 27.0 27.0 27.0 27.0 27.0 27.0 27.0 27.0 27.1 27.2 27.2 27.2 27.2 27.2 27.3 27.5 27.5 27.5 27.6 27.7 27.7 27.7 27.7 27.8 27.8 27.8 27.8 27.7 27.8 27.9 28.0 28.0 28.0 28.0 28.0 28.1 27.9 27.8 27.9 27.9 27.9 28.1 28.2 28.3 28.3 7.0 7.0 6.9 6.8 7.0 7.1 7.1 7.1 7.2 7.3 7.3 7.2 7.0 6.8 7.0 7.1 7.3 7.1 7.2 7.3 7.0 7.1 7.1 7.0 6.9 6.9 7.0 7.0 7.0 6.9 6.9 7.0 7.0 7.1 7.0 7.0 7.1 7.2 7.2 7.2 1 7.0 7.1 7.1 7.2 7.2 7.1 7.1 7.1 7.1 7.2 7.2 7.2 7.2 7.2 7.3 7.3 7.3 7.4 7.4 7.5 7.5 7.3 7.1 7.2 7.2 7.2 7.1 7.2 7.2 7.2 7.3 7.3 7.3 7.3 7.2 7.2 7.3 7.3 7.3 7.2 7.1 7.1 7.1 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.1 7.1 7.1 7.0 7.0 7.0 7.0 7.1 7.0 7.0 7.1 7.3 7.3 7.2 7.3 7.2 7.0 7.0 7.1 5.05 4.99 4.91 4.82 4.96 5.09 5.12 5.15 5.25 5.36 5.31 5.26 5.05 4.84 4.97 5.10 5.33 5.09 5.23 5.36 5.06 5.09 5.17 5.06 4.95 4.95 4.96 5.01 5.06 4.92 4.94 4.96 5.02 5.09 5.02 4.96 5.10 5.25 5.24 5.24 5.11 4.98 5.07 5.17 5.19 5.22 5.17 5.12 5.14 5.17 5.24 5.31 5.27 5.23 5.30 5.38 5.37 5.36 5.44 5.53 5.58 5.63 5.39 5.16 5.23 5.30 5.23 5.17 5.20 5.22 5.29 5.36 5.38 5.41 5.33 5.27 5.30 5.33 5.35 5.36 5.22 5.09 5.11 5.13 5.06 4.99 5.02 5.05 5.01 4.98 5.01 5.03 5.09 5.16 5.08 5.00 4.99 4.98 5.02 5.07 5.04 5.01 5.17 5.34 5.31 5.28 5.35 5.21 5.07 5.06 5.07 1810 1815 1820 1825 1830 1835 1840 1845 1850 1855 1860 1865 1870 1875 1880 1885 1895 1905 1910 1915 1925 1935 1945 1950 1955 1960 1965 1970 1975 1985 1990 1995 2000 2005 2010 2015 2020 2025 2030 2035 2040 2045 2050 2055 2060 2065 2070 2075 2080 2085 2090 2095 2100 2105 2110 2115 2120 2125 2130 2135 2140 2145 2150 2155 2160 2165 2170 2175 2180 2185 2190 2195 2200 2205 2210 2215 2220 2225 2230 2235 2240 2245 2250 2255 2260 2265 2270 2275 2280 2285 2290 2295 2300 2305 2310 2315 2320 2325 2330 2335 2340 2345 2350 2355 2360 2365 2375 2380 2385 2395 2400 28.3 28.5 28.6 28.7 28.7 28.7 28.8 28.6 28.4 28.5 28.6 28.5 28.4 28.4 28.5 28.5 28.6 28.5 28.5 28.5 28.6 28.5 28.5 28.6 28.6 28.6 28.7 28.9 28.9 29.1 29.1 29.1 29.1 29.1 29.1 29.2 29.2 29.3 29.3 29.3 29.3 29.2 29.2 29.3 29.5 29.4 29.4 29.5 29.8 29.7 29.7 29.8 29.9 29.8 29.9 29.9 29.9 29.9 29.9 29.8 29.8 29.9 29.9 29.8 29.8 29.9 29.9 29.8 29.8 29.8 29.8 29.8 29.7 29.7 29.7 29.7 29.7 29.8 29.8 29.7 29.5 29.8 30.0 30.0 30.1 30.1 30.2 30.3 30.0 30.3 30.3 30.3 30.2 30.3 30.2 30.1 30.3 304 30.4 30.5 30.5 30.6 30.5 30.6 30.9 31.0 31.1 31.1 31.1 31.2 30.9 7.1 6.9 6.8 6.8 6.8 6.7 6.7 6.9 7.1 7.0 7.0 7.1 7.3 7.2 7.2 7.2 7.2 7.3 7.4 7.3 7.3 7.4 7.5 7.4 7.5 7.5 7.4 7.2 7.2 7.1 7.0 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.0 7.1 7.1 7.2 7.2 7.2 7.0 7.1 7.1 7.0 6.8 6.9 6.9 6.8 6.8 6.8 6.8 6.8 6.8 6.9 6.9 6.9 7.1 6.9 7.0 7.1 7.1 7.0 7.1 7.2 7.2 7.2 7.2 7.2 7.3 7.3 7.4 7.4 7.5 7.3 7.4 7.5 7.7 7.4 7.3 7.2 7.2 7.2 7.1 7.0 7.0 7.0 7.1 7.1 7.2 7.2 7.3 7.4 7.2 7.2 7.1 7.0 7.1 7.0 7.1 7.1 6.8 6.7 6.6 6.6 6.7 6.6 6.9 5.08 4.91 4.74 4.75 4.76 4.72 4.69 4.90 5.12 5.07 5.01 5.17 5.33 5.28 5.22 5.22 5.24 5.36 5.45 5.38 5.35 5.54 5.59 5.48 5.57 5.65 5.47 5.29 5.22 5.11 5.06 5.09 5.11 5.16 5.15 5.13 5.18 5.08 5.05 5.07 5.13 5.23 5.27 5.21 5.02 5.08 5.10 5.01 4.76 4.89 4.86 4.78 4.75 4.81 4.78 4.76 4.84 4.89 4.90 4.94 5.08 4.92 4.98 5.10 5.09 5.00 5.07 5.20 5.27 5.27 5.28 5.30 5.38 5.41 5.47 5.54 5.57 5.43 5.45 5.61 5.86 5.53 5.35 5.28 5.24 5.20 5.12 5.05 5.06 5.05 5.07 5.13 5.23 5.20 5.35 5.45 5.27 5.22 5.13 5.07 5.11 5.07 5.12 5.08 4.79 4.66 4.60 4.61 4.62 4.60 4.93 2405 2410 2415 2420 2425 2430 2435 2440 2445 2450 2455 2460 2465 2470 2475 2480 2490 2500 2505 2510 2520 2530 2540 2545 2550 2555 2560 2565 2570 2580 2585 2590 2595 2600 2605 2610 2615 2620 2625 2630 2635 2640 2645 2650 2655 2660 2665 2670 2675 2680 2685 2690 2695 2700 2705 2710 2715 2720 2725 2730 2735 2740 2745 2750 2755 2760 2765 2770 2775 2780 2785 2790 2795 2800 2805 2810 2815 2820 2825 2830 2835 2840 2845 2850 2855 2860 2865 2870 2875 2880 2885 2890 2895 2900 2905 2910 2915 2920 2925 2930 2935 2940 2945 2950 2955 2960 2970 2975 2980 2990 3000 30.9 30.9 31.0 31.0 31.1 31.0 31.0 31.2 31.1 31.0 31.0 30.9 31.1 31.3 31.4 31.3 31.1 30.9 31.1 31.0 31.2 31.0 31.2 31.0 31.0 31.1 31.0 30.8 31.1 31.6 31.6 31.6 31.5 31.6 31.3 31.4 31.7 31.6 31.4 31.6 31.8 31.7 31.7 31.8 31.8 31.7 32.0 32.0 31.9 31.7 31.9 32.1 32.1 32.0 32.0 32.1 32.1 32.4 32.2 31.9 31.6 31.6 31.9 32.0 32.0 32.0 32.2 32.3 32.3 32.3 32.7 32.8 32.8 32.5 32.5 32.5 32.3 32.2 32.3 32.4 32.5 32.5 32.6 32.6 32.4 32.4 32.8 33.0 33.0 32.5 33.0 33.1 33.1 33.0 32.9 32.9 33.1 33.3 33.0 33.0 33.0 33.0 33.1 33.2 33.3 33.3 33.3 33.0 32.9 32.9 33.4 6.9 6.9 6.9 6.8 6.8 6.9 6.9 6.8 6.9 7.0 7.0 7.2 6.9 6.8 6.7 6.8 7.0 7.2 7.1 7.2 7.0 7.3 7.1 7.3 7.3 7.2 7.4 7.6 7.3 6.9 6.8 6.9 7.0 6.9 7.2 7.1 6.9 7.0 7.1 7.0 6.8 7.0 6.9 6.9 6.9 7.0 6.7 6.7 6.8 7.0 6.8 6.7 6.7 6.8 6.8 6.8 6.7 6.5 6.7 7.0 7.4 7.1 7.0 6.9 7.0 7.0 6.8 6.8 6.8 6.8 6.4 6.3 6.4 6.7 6.6 6.7 6.9 7.0 7.0 6.8 6.7 6.8 6.6 6.7 6.9 7.0 6.5 6.3 6.4 6.9 6.4 6.3 6.4 6.4 6.6 6.5 6.4 6.2 6.5 6.5 6.5 6.5 6.5 6.4 6.3 6.3 6.4 6.6 6.8 6.8 6.4 4.93 4.89 4.85 4.82 4.81 4.87 4.88 4.74 4.91 4.96 5.01 5.19 4.95 4.76 4.69 4.79 4.99 5.27 5.15 5.22 5.05 5.37 5.09 5.43 5.39 5.30 5.47 5.70 5.37 4.87 4.79 4.88 4.97 4.86 5.30 5.15 4.88 4.97 5.17 5.00 4.82 4.98 4.93 4.85 4.85 5.02 4.71 4.67 4.81 5.04 4.83 4.72 4.71 4.81 4.80 4.79 4.71 4.47 4.63 5.05 5.44 5.46 5.06 4.94 4.98 5.06 4.80 4.73 4.77 4.82 4.41 4.25 4.33 4.66 4.62 4.70 4.85 5.01 4.96 4.80 4.68 4.78 4.62 4.70 4.88 4.98 4.52 4.30 4.38 4.87 4.40 4.28 4.34 4.41 4.58 4.51 4.33 4.16 4.45 4.51 4.48 4.52 4.42 4.32 4.27 4.30 4.36 4.60 4.74 4.82 4.33 Page 29 of 30 Report ID: TEXEMC_EN.23555_rev1.docx Date of Issue: 14-Apr-13 14 APPENDIX F A AC AM AVRG cm dB dBm dB(V) dB(V/m) dB(A) DC EUT F GHz GND H HL Hz k kHz m MHz min mm ms s NA OATS QP RE RF rms Rx s T Tx V WB Abbreviations and acronyms ampere alternating current amplitude modulation average (detector) centimeter decibel decibel referred to one milliwatt decibel referred to one microvolt decibel referred to one microvolt per meter decibel referred to one microampere direct current equipment under test frequency gigahertz ground height Hermon laboratories hertz kilo kilohertz meter megahertz minute millimeter millisecond microsecond not applicable open area test site Ohm quasi-peak radiated emission radio frequency root mean square receive second temperature transmit volt wideband END OF DOCUMENT Page 30 of 30