Always. Reliable. Tight. Catalogue Cable Entries cablepipebuildingentry+ Solutionmap Cable. Pipe. Building Entry. Always. Reliable. Tight. Catalogue Content Cable entries System covers and system sealings for cables System covers for the connection of cable ducts 14–15 Cable entry system 16–18 Accessories 19–19 Cable entries • Cable sealing system 150 Wall inserts and aluminium flange 6– 7 8–13 System covers for cables 22 – 23 System covers for the connection of cable ducts 24–25 Cable entry system 26 – 28 Accessories 29–29 Press seals • Cable sealing system 90 Wall inserts and aluminium flange 20–21 Press seals • Cable press seals Standard press seals 30 – 31 Individual press seals 32 – 35 (closed and split) Extra • Wall sleeves Standard wall sleeves / wall sleeves with flanges 36 – 39 Extra • Earthings 40–47 • Fire protection 48–49 • Roof entries 50–51 • Foundation pipes 52–53 General sales terms and delivery conditions 54–55 General Terms of Business Electricity, telecommunication, water, waste water, gas or district heating - whenever a perfectly safe sealing of building entries is required, Hauff-Technik offers the best possible solution. Innovative cable and pipe entries, building entries and trenchless house connections of professional quality. All from one source. Out of the box or customized products. For highest efficiency, user-friendliness and longevity in all buildings. From single-family homes to complex major projects. Always Hauff. Always reliable. Always tight. Please find our currently valid prices in our price lists 2 cablepipebuildingentry+ 3 Application tachometer To determine your specific requirements ia r eals - dep pipe s end nd ing a e g eepa water, ground wat e s g n l i e nd on b : sta water, waterproof concrete stre r, strata n a o i ss c w c at ng plic pressi Ap lass 1 ate r, Wall type basement/ Wall structure sp if ic r – 0.3 0–> re qu i re m en t 3m 0.3 ba r, i ns ta – >3 m 0 – 0.1 b ar, in stal lati on de pt h0 0– Sealing width Sealing according to DIN 18195 - Part 6 Standing seepage water and pressing water No. 1 No. 5 brick-built basement wall brick-built basement wall sealing on outside of building sealing on outside of building No. 2 concreted basement No. 6 concreted basement Concreted basement sealing on outside of building No. 3 Products according to load cases DIN 18195/stress class waterproof concrete, example used is press seal for cables Product group Sealing according to DIN 18195 – Part 4 Soil humidity and non-standing seepage water Brick-built basement wall mal), cal, ther hemi ss (c tions ts stre di e n ds, higlhation con l loa nsta em i r : shockficult i f u q ation di ic pl Ap 1m stallation depth 0 bar, in – h0 ept nd tio lla Applicatio rain water n: non-s Se , spla t sh w andin le ater g se ,w ct e p ate a io rpr ge w oo a n f c te on r, s cr cre oi te l h st um re id ss i cla , ty ss 2 ec e i r te fo Overview wall structure / Sealing of building entries Basis to determine the appropriate cable and pipe entry systems double wall / element wall sealing on outside of building No. 7 double wall / element wall Double wall / Element wall sealing on outside of building sealing on outside of building Catalogue page No. 4 HRD 1 30 mm 32 HRD SG 40 mm 30 HRD 2 60 mm 34 thermal insulation Double wall / Element wall with thermal insulation No. 8 thermal insulation double wall / element wall double wall / element wall sealing on outside of building sealing on outside of building Please note: Wall inserts and flanges must be used in compliance with DIN 18195 and/or EN206-1! Waterproof concrete according to EN206-1 Concreted basement with waterproof concrete No. 9 concreted basement Double wall / element wall with waterproof concrete No. 10 double wall / element wall Double wall / element wall with waterproof concrete and thermal insulation No. 11 thermal insulation double wall / element wall If you do not find your wall structure among above examples, kindly let us have a sketch. 4 + 5 cablepipebuildingentry 5 Cable sealing system 150 Wall inserts and aluminium flange Cable sealing system 150 Wall inserts and aluminium flange HSI 150 – Wall inserts • waterproof concrete stress class 1 Item Features and technical data Wall insert – HSI 150-K/X: Wall insert – HSI 150-K2/X: Wall insert – HSI 150-GSM: • single-sided connection of systemsealing at the outside of the building • minimum wall thickness 70 mm • blind cover and blind plate (to be knocked out) guarantee double safety at wall thicknesses 70 – 150 mm (in 10 mm steps) • available for individual wall thicknesses ≥ 150 mm • plug-in frame system for block assembly • pressure-tight up to 2.5 bar after concreting • connections of system sealing possible on both sides • minimum wall thickness 100 mm • available for individual wall thicknesses ≥ 100 mm • plug-in frame system for block assembly, available ex stock • closed on both sides with blind system cover • special designs for double wall/ element walls available • pressure-tight up to 2.5 bar after concreting • single-sided connection of system sealing, with integrated plug-in socket to connect smooth cable ducts • no additional duct connection material necessary • minimum wall thickness for pipe connection 110 and 125 mm diameter: 120 mm • minimum wall thickness for pipe connection 160 mm diameter: 180 mm • maximum wall thickness: 500 mm • pressure-tight up to 0.5 bar depending on the cable duct used Single wall insert from wall thickness 70 mm Double wall insert from wall thickness 100 mm Double wall insert for element walls 430 mm frame size 220 x 220 mm 210 mm 210 mm Single wall insert with integrated plug-in socket Ø 110 mm from wall thickness 120 mm Single wall insert with integrated plug-in socket Ø 125 mm from wall thickness 120 mm Installation movie 1.060 mm Article code HSI 150-K/X X = wall thickness in mm HSI 150-K2/X X = wall thickness in mm HSI 150-K2-EW/X X = wall thickness in mm HSI 150-GSM 110/X** X = wall thickness in mm HSI 150-GSM 125/X** X = wall thickness in mm Article number Picture Cable entries Application: 2140100XXX * 2140300XXX * 2140304XXX * – – Example as a 2x5 block for 200 mm wall thickness. Article code: HSI 150-2x5-K2/200 Single wall insert with integrated plug-in socket Ø 160 mm from wall thickness 180 mm combination in packages only possible with spacer Spacer one set consists of 2 pieces to increase center distances by 40 mm, possibility to combine HSI 150 and HSI 90 in bundles HSI 150-GSM 160/X X = wall thickness in mm HSI-AH 40 2120209XXX * 2101090010 ** restrictions regarding number and size of cables may occur * Please complete article number respectively: XXX = wall thickness in mm standard length: 070 up to 500 mm (gradation in 10 mm) Double wall insert HSI 150 fixed as package into the formwork Slanted wall inserts (30°, 45° und 60°) and customized solutions according to DIN 18195 part 6 available on request. Application: non-standing seepage water, waterproof concrete stress class 1 Aluminium flange HSI 150-DF 235 mm 6 core drilling max. 150 mm diameter Item Article code Article number Aluminium flange incl. fastenings made of stainless steel V4A (AISI 316L) for concrete walls HSI 150-DF 2118010000 Cartridge of 300 ml colour: grey elastic sealant to optimize wall surface when used with sealing flange Sikaflex-11 FC 0505071620 Picture 67 mm 10 mm • connection to system sealing possible • aluminium flange with KTL (cataphoretic) - coating (optimised protection against corrosion) • for retrofit fixing • core drilling max. 150 mm diameter • installation on container walls possible • including chloroprene (CR) surface seal, 10 mm thick and fastenings made from stainless steel V4A (AISI 316L) for concrete walls 235 mm Aluminium flange – HSI 150-DF: Sectional drawing Spacing dimensions 85 mm Features and technical data HSI 150 – Aluminium flange Min. 235 mm • cablepipebuildingentry+ 7 Cable sealing system 150 System covers and system sealings for cables Cable sealing system 150 System covers and system sealings for cables HSI 150 – System cover heat shrink method Item Area of application cable/pipe diameter Article code Article number System cover, closed sealing cover Blind cover HSI 150-D 2101100000 System cover with 1 socket incl. 1 piece heat-shrink sleeve 1 piece centering tape 25 – 78 mm HSI 150-D1/80 2101100010 System cover with 3 sockets incl. 3 pieces heat-shrink sleeves 3 pieces centering tape 22 – 56 mm HSI 150-D3/58 2101100049 System cover with 7 sockets incl. 7 pieces heat-shrink sleeves 12 – 31 mm HSI 150-D7/33 2101100059 Article code Article number VS 32/34 2140403234 VS 58/60 2140405860 HSI-ZB 2102200700 Picture System cover heat shrink method – HSI 150-D1/80, -D3/58 and -D7/33: • wide application area • easy installation with bayonet catch • including centering tape at HSI 150-D1/80 and HSI 150-D3/58 • unused opening can be closed off with blind plugs VS32/34 respectively VS 58/60 • also available with cold shrink sleeves • UV- and ozone resistant • resistant to transformer oil Cable entries Features and technical data Types with cold shrink sleeves available on request. HSI 150 – Accessories Item Transformer station entry: low-voltage cable sealed with HSI 150-D1/80 Centering tape installed in system cover socket of HSI 150-D3/58 Sealing plug for system cover HSI 150-D3/58 (available as single unit or packing unit = 10 pcs) Cross-section of a concrete wall flexible, pressurestable KES-hose stainless steel hose clamp wrench size13 concrete wall 3-ribbed seal extension pipe Sealing plug for system cover HSI 150-D7/33 (available as single unit or packing unit = 10 pcs) wall insert Application To seal unused sockets Centering tape – For centering and set of 3 pieces elastomer fixing the cables into strips the system cover sockets 30 x 430 mm for optimal shrinking clamping nut system cover cable Picture HSI 150 – Replacement -/ Repair shrink sleeves heat shrink-fit sleeve rubber sleeve Item for system cover Article code Article number HSI 150-D1/80 TM2.200.92.25 0349210010 HSI 150-D3/58 TM2.200.75.22 0349116010 HSI 150-D7/33 TM2.150.43.12 0349010005 HSI 150-D1/80 TMR3.250.107.29 0350070000 HSI 150-D3/58 TMR3.250.84.20 0350040000 HSI 150-D7/33 TMR3.250.53.13 0350030000 sliding and O-ring x = wall or masonry thickness Replacement shrink sleeves for HSI 150 Repair sleeves for HSI 150 Installation movie 8 cablepipebuildingentry+ 9 Cable sealing system 150 System covers and system sealings for cables Cable sealing system 150 System covers and system sealings for cables HSI 150 - DG – System cover for new and retrofit installation System cover for new and retrofit installation – HSI 150-DG: • split seal for new and retrofit installation • individual adjustment to the diameter of the laid cables on site • inscribed segment rings • blind plugs for HSI 150-DG-3/24-54 and HSI 150-DG-6/10-36 included in the delivery • transformer oil leak-tightness, tested over 90 days – KIWA Institute • plastic pressure plates made of polyamide 6.6 with 30 % glass-fibre reinforcement • V2A (AISI 304L) stainless steel screws and nuts • pressure-tight up to 2.5 bar Area of application cable/pipe OD Article code Article number Split system cover with 1 opening incl. split adapter ring 36 – 70 mm HSI 150-DG-1/36-70 2102200020 Split system cover with 1 opening incl. split adapter ring 70 – 112 mm HSI 150-DG-1/70-112 2102200030 Split system cover with 3 openings incl. split adapter ring and 3 pieces blind plugs 24 – 54 mm HSI 150-DG-3/24-54 2102200000 Split system cover with 6 openings incl. split adapter ring and 6 pieces blind plugs 10 – 36 mm HSI 150-DG-6/10-36 2102200010 Picture Cable entries Features and technical data Item Scope of delivery of HSI 150-DG includes: lubricating stick GM, knife, cleaning cloth HSI 150 - DG – Accessories Item Low-voltage cables sealed with HSI 150-DG-6/10-36 Pressure plate cover HSI 150-PA-3/24-54 Various installation stages of HSI 150-DG-3/24-54 HSI 150-DG: inscription of diameters on segments Application Article code Article number Press plate cover for HSI 150-DG-3/24-54 For protecting the threads against HSI 150-PA-3/24-54 dirt 2102200400 Press plate cover for HSI 150-DG-6/10-36 For protecting the threads against HSI 150-PA-6/10-36 dirt 2102200410 Torque wrench 4-20 Nm ¼ inch 1 adapater for cordless screwdriver, square end, ¼ inch 2 extensions, 150 mm ¼ inch 1 extension 100 mm, ¼ inch 1 wrench socket M6, AF 5, ¼ inch 1 wrench socket, M6, 100 mm with ball head, ¼ inch Tool for installation of system cover HSI 150-DG HSI 150-DG-W Picture 2102200600 Installation movie 10 cablepipebuildingentry+ 11 Cable sealing system 150 System covers and system sealings for cables Cable sealing system 150 System covers and system sealings for cables HSI 150-SEGMENTO SEGMENTO – HSI 150-SEGMENTO: • • • • • • • • • • particularly flexible and gentle sealing for cables with 5 to 31 mm diameter individual clamping of segments no time-consuming modular design easy and quick installation of segments segments can be combined as necessary integrated torque control system simple reinstallation possible all segment openings closed with blind plugs gas- and watertight up to 0.5 bar when installed on outside of building Article code Article number System lid as segment receptacle HSI 150-S3 2300100000 The violet segment application area for 2 cables, diameter 20-31 mm incl. 2 blind plugs SEG 2/31 2300130000 The yellow segment application area for 3 cables, diameter 20-26 mm incl. 3 blind plugs SEG 3/26 2300140000 The blue segment application area for 6 cables, diameter 15-21 mm incl. 6 blind plugs SEG 6/21 2300150000 The orange segment application area for 8 cables, diameter 5-15 mm incl. 8 blind plugs SEG 8/15 2300160000 Picture Cable entries Features and technical data Item Combination kit SEGMENTO HSI 150 - wall insert with SEGMENTO sealing of control lines in a substation HSI 150 - SEGMENTO – with integrated torque control system and bling plugs Item Article code KKS combination kit for pressure-tight outside sealing of core drillings with a diameter of 150 mm consisting of: 1x aluminium flange HSI 150-DF with fastenings, 1x system cover HSI 150-S3, 3x selected segments SEG x/xx, 1x GMS lubricant, 1x installation instructions KKS ordering example: KKS 338 comprise: 1x HSI 150-DF, 1x HSI 150-S3, 2x SEG 3/26, 1x SEG 8/15, 1x GMS Article number Picture – SEGMENTO accessories Sealing of cables for street lighting with SEGMENTO Item Article code Article number Lubricant SEGMENTO 10 g GMS 2300310000 Cable diameter gauge SEGMENTO to determin the suitable segments according to the cable diamter BSS 2300320000 Torque screwdriver (1,2 Nm) SEGMENTO with acoustic signal DMS 2300300000 Picture Installation instructions 12 cablepipebuildingentry+ 13 Cable sealing system 150 System covers for the connection of cable ducts Cable sealing system 150 System covers for the connection of cable ducts HSI 150 – Plug-in socket system for smooth pipes Plug-in socket system – HSI 150 – D (pipe OD) GSM: Sleeve method – HSI 150 – M (pipe OD): Cold shrink method – HSI 150 – D (pipe OD) KS: • for smooth pipes / ducts • easy and quick installation, no additional connecting components necessary • economic solution • compact design • pressure-tight up to 0.5 bar, depending on the pipe / duct used • can be used with smooth and corrugated pipes • patented clip ring technology for sealing of corrugated pipes (indicate pipe type and pipe manufacturer, please) • mechanically stable, elastic connection using special sleeves and tightening straps made from stainless steel V4A (AISI 316L) • pressure-tight up to 0.5 bar, depending on the pipe / duct used • for corrugated pipes • shrink method, no tools necessary • stress-free sealing for pressure-sensitive pipes • pressure-tight up to 0.5 bar, depending on the pipe / duct used Pipe OD Article code Article number System cover for pipe connection 110 mm HSI 150-D 110-GSM 2101100105 System cover for pipe connection 125 mm HSI 150-D 125-GSM 2101100115 System cover for pipe connection 160 mm HSI 150-D 160-GSM 2101100125 Picture Cable entries Features and technical data Item HSI 150 – Rubber sleeves for smooth and corrugated pipes Item System cover for smooth pipes System cover for corrugated pipes incl. clip rings System cover for smooth pipes System cover for corrugated pipes incl. clip rings System cover for smooth pipes System cover for smooth pipes Connection of corrugated pipes with cold shrink method HSI 150-M 168 System cover for corrugated pipes incl. clip rings Pipe OD Article code Article number HSI 150-M 110 2126010110 HSI 150-M 110-WR* for Kabuflex: 2126010113 HSI 150-M 125 2126010125 HSI 150-M 125-WR* for Kabuflex: 2126010007 HSI 150-M 140 2126010140 HSI 150-M 168 2126010000 HSI 150-M 168-WR* for Kabuflex: 2126010001 110 mm 125 mm 140 mm 160 mm Picture *Kindly indicate pipe manufacturer and pipe type in your order. (indicate pipe type and pipe manufacturer) For each pipe connection 2 profile sealing rings are necessary (available from the pipe manufacturer, to be provided on-site). HSI 150 – Cold shrink sleeves for corrugated pipes Connection of corrugated pipes with cold shrink sleeves HSI 150-D 110-KS Connection of rigid cable protection pipe DN 125 with HSI 150-D 125-GSM Item Pipe OD Article code Article number System cover for corrugated pipes 110 mm HSI 150-D 110-KS 2102100060 System cover for corrugated pipes 125 mm HSI 150-D 125-KS 2102100070 Picture HSI 150 – Replacement cold shrink sleeves Item Replacement shrink-fit sleeves for HSI 150 Installation movie 14 For system cover Article code Article number HSI 150-D 110-KS KS 223.119.56 0311031201 HSI 150-D 125-KS KS 240.154.76 0311031000 cablepipebuildingentry+ 15 Cable sealing system 150 Cable entry system Cable sealing system 150 Cable entry system KES-M 150 – Cable entry system • waterproof concrete stress class 1 Features and technical data Cable entry system – KES-M 150: • pressure-tight ducting system up to 2.5 bar (outer pressure) for connecting HSI 150-wall inserts • high mechanical stability • elastic connection with special system sleeves and straps made of stainless steel • smooth inner surface for gentle cable feeding • sealing of cables with heat shrink or cold shrink sleeves or rubber press seals • adaption with common cable ducts possible • also available as role commodity (up to a length of 25 m), extension possible with connection sleeve KES-M 150 HTV Pressure-tight connection of Hateflex 14150 to HSI 150-wall inserts Entry of KES-systems through slab. auxiliary construction provided on site (bending radius min. 1 m) Cross-section of a concrete wall flexible, pressurestable KES-hose stainless steel hose clamp wrench size13 concrete wall 3-ribbed seal extension pipe wall insert clamping nut system cover cable Pressure-tight connection of Hateflex 14150 to HSI 150-wall inserts heat shrink-fit sleeve rubber sleeve sliding and O-ring Item Article code Article number Spiral hose with a smooth inner surface, for gentle cable feeding inner diameter = 150 mm minimum length 1000 mm Hateflex 14150/1000 – Connection sleeve for hose extension / connection of Hateflex 14150 KES-M 150 HTV 2128020000 System cover for pressure-tight connection of spiral hose Hateflex 14150 to wall insert HSI 150 KES-M 150-D 2125810000 Wall insert including blind cover for connecting HSI 150 * system cover to end of spiral hose Hateflex 14150 KES-M 150-KVB 2125811000 System cover with 3 sockets and sleeve to seal 3 cables of diam. 22 - 56 mm on end of spiral hose Hateflex 14150 KES-M 150-D3/58 2125815001 System cover with 7 sockets and sleeve to seal 7 cables of diam. 12-31 mm on end of spiral hose on Hateflex 14150 KES-M 150-D7/33 2125816001 Sleeve to be used with interchangeable insert WE 160-z/d to seal cables on end of spiral hose Hateflex 14150 (installation before cables are pulled through) KES-M 150-WE 2125817100 WE 160-z/d 2125817110 Interchangeable insert to be used with sleeve KES-M 150-WE customized according to cables to be installed z= number of cables d= cable diameter Picture Cable entries Application: * However the split system cover HSI 150-DG as well as HRD press seals are not suitable for the use in an assembly frame of the variant KES-M 150-KVB that is not embedded in concrete. x = wall or masonry thickness Installation movie 16 cablepipebuildingentry+ 17 Cable sealing system 150 Cable entry system Cable sealing system 150 Accessories HSI 150 – Accessories Item Article code Article number Connection sleeve for connecting rigid cable ducts OD = 110 mm * to spiral hose Hateflex 14150 KES-M 150-M 110 2125814000 Article code Article number SLS 6G 0352010000 SLS 6GD 0352010100 VS 32/34 2140403234 VS 58/60 2140405860 Centering tape – set, consisting of 3 pieces elastomer strips 30 x 430 mm. For centering and fixing the cables into the system cover sockets for optimal shrinking. HSI-ZB 2102200700 3-finger sleeve for system cover HSI 150-D7/33 AK.3F.44.13.16.4,2 3-finger sleeve for system cover HSI 150-D3/58 AK.3F.71.22.26.9 4-finger sleeve for system cover HSI 150-D7/33 AK.4F.44.19.20.7 4-finger sleeve for system cover HSI 150-D3/58 AK.4F.80.25.27.9 Flexible pin spanner (buildings with perimeter insulation up to 100 mm) Sealing plug for system cover HSI 150-D7/33 (available as single unit or packing unit = 10 pcs) for Kabuflex: 1630001730 CR 110 KES-M 150-M 125 1 set of clip rings to stabilize the corrugated pipe within the sleeve (kindly indicate pipe manufacturer and pipe type in your order) Connection sleeve for connecting rigid cable ducts OD = 160 mm * to spiral hose Hateflex 14150 Item Flexible pin spanner 1 set of clip rings to stabilize the corrugated pipe within the sleeve (kindly indicate pipe manufacturer and pipe type in your order) Connection sleeve for connecting rigid cable ducts OD = 125 mm * to spiral hose Hateflex 14150 Picture Sealing plug for system cover HSI 150-D3/58 (available as single unit or packing unit = 10 pcs) 2125813000 for Kabuflex: 1630001750 CR 125 KES-M 150-M 160 2125812000 0307020000 0307040000 0308020000 1 set of clip rings to stabilize the corrugated pipe within the sleeve (kindly indicate pipe manufacturer and pipe type in your order) CR 160 Rigid pipe section OD = 160 mm with sleeve for connection to spiral hose Hateflex 14150 (tight wall sealing in core drillings when used together with HRD press seals). KES-M 150-R 160 2125818000 Lubricant 200 g GML 1591000754 Spacer 2x3 for positioning of hose packages with Hateflex 14150 KES 150-2x3 KA 2101090200 Hot-melt tape, cold welding, length 3 m, width approx. 35 mm Hatetherm Scapa 0485 0316010000 Cable cleaner, content: 1000 ml, quick and residue-free evaporation KR M.T.X. 0331010100 Cartridge of 300 ml colour: grey elastic sealant to optimize wall surface when used with sealing flange Sikaflex-11 FC 0505071620 Torque srewdriver (1,2 Nm) SEGMENTO with acoustic signal DMS 2300300000 for Kabuflex: 1630001770 Picture Cable entries KES-M 150 – Cable entry systems 0308040000 * additional clip rings CR are necessary to connect corrugated pipes For each pipe connection 2 profile sealing rings are necessary (available from the pipe manufacturer, to be provided on-site). HSI 150 / KES 150 – Tool and assembly set Item Article code Tool set for pressure-tight strap assembly, consisting of 1 torque 4-20 Nm, ¼ inch, 1 extension 150 mm, ¼ inch, 1 socket for hexagon spanner SWS 13, ¼ inch KES-M-W Torque wrench 4-20 Nm ¼ inch 1 adapater for cordless screwdriver, square end, ¼ inch 2 extensions, 150 mm ¼ inch 1 extension 100 mm, ¼ inch 1 wrench socket M6, AF 5, ¼ inch 1 wrench socket, M6, 100 mm with ball head, ¼ inch HSI 150-DG-W 18 Article number Picture 2128030000 2102200600 cablepipebuildingentry+ 19 Cable sealing system 90 Wall inserts and aluminium flange Cable sealing system 90 Wall inserts and aluminium flange HSI 90 – Wall inserts • waterproof concrete stress class 1 Item Features and technical data • single-sided connection to system sealing possible • minimum wall thickness 70 mm • available in individual thicknesses ≥ 70 mm • plug-in frame system for block assembly on-site • pressure-tight cover • pressure-tight up to 2 bar after concreting • connections to system sealing possible on both sides • minimum wall thickness 100 mm • available in individual wall thicknesses ≥ 100 mm • plug-in frame system for block assembly, available ex stock • pressure-tight cover on both sides • pressure-tight up to 2 bar after concreting frame size 145 x 145 mm 135 mm Single wall insert from wall thickness 70 mm Double wall insert from wall thickness 100 mm HSI 90-K/X X = wall thickness in mm HSI 90-K2/X X = wall thickness in mm Article number Picture – – 280 mm Wall insert – HSI 90-K2/X: 135 mm Wall insert – HSI 90-K/X: Article code Cable entries Application: 685 mm Example as a 2x5 block for 200 mm wall thickness: Article code: HSI 90-2x5-K2/200 Installation movie Double wall insert HSI 90 fixed as package into the formwork HSI 90 – Aluminium flange Application: non-standing seepage water, waterproof concrete stress class 1 Features and technical data Aluminium flange HSI 90-DF Sectional drawing Spacing dimensions Aluminium flange – HSI 90-DF: Min. 185 mm core drilling max. 90 mm diameter 20 Item Article code Article number Aluminium flange incl. fastenings made of stainless steel V4A (AISI 316L) for stainless steel HSI 90-DF 2203010001 Cartridge of 300 ml colour: grey elastic sealant to optimize wall surface when used with sealing flange Sikaflex-11 FC 0505071620 Picture 185 mm 185 mm • connection to system sealing possible • aluminium flange with KTL (cataphoretic) - coating (optimum protection against corrosion) • for retrofit installation • core drilling max. 90 mm diameter • installation on container walls possible • including chloroprene (CR) surface seal, 10 mm thick and fastenings made of stainless steel V4A (AISI 316L) for concrete walls 46 mm 95 mm • 10 mm cablepipebuildingentry+ 21 Cable sealing system 90 System covers for cables Cable sealing system 90 System covers for cables HSI 90 – System cover heat shrink method Item Area of application cable/pipe diameter Article code Article number System cover, closed - sealing cover Blind cover HSI 90-D 2205010000 System cover with 1 socket incl. 1 piece heat-shrink sleeve 1 piece centering tape 25 – 72 mm HSI 90-D1/75 2206040000 System cover with 3 sockets incl. 3 pieces heat-shrink sleeves 12 – 30 mm HSI 90-D3/32 2206020000 System cover with 6 sockets incl. 6 pieces heat-shrink sleeves 8 – 18 mm HSI 90-D6/20 2206030000 Picture System cover heat shrink method – HSI 90-D1/75, -D3/32 and -D6/20: • wide application area • easy installation with bayonet catch • including centering tape at HSI 90-D1/75 • unused opening can be closed off with blind plugs VS 20, VS 32/34 respectively • also available in cold shrink-fit method • UV- and ozone resistant • resistant to transformer oil Cable entries Features and technical data Types with cold shrink sleeves available on request. HSI 90 – Accessories Item Transformer station entry: low-voltage cable sealed with HSI 90-D1/75 and HSI 90-D3/32 Sealing plug for system cover HSI 90-D6/20 (available as single unit or packing unit = 10 pcs) Cross-section of a concrete wall flexible, pressurestable KES-hose stainless steel hose clamp wrench size13 3-ribbed seal wall insert Article code Article number VS 20 2225819200 VS 32/34 2140403234 HSI-ZB 2102200700 Picture To seal unused sockets Sealing plug for system cover HSI 90-D3/32 (available as single unit or packing unit = 10 pcs) concrete wall extension pipe Application clamping nut Centering tape – set, consisting of 3 pieces elastomer strips 30 x 430 mm system cover cable heat shrink-fit sleeve rubber sleeve For centering and fixing the cables into the system cover sockets for optimal shrinking. HSI 90 – Replacement -/ Repair heat shrink sleeves sliding and O-ring Item for system cover Article code Article number HSI 90-D1/75 TM2.200.92.25 0349210010 HSI 90-D3/32 TM2.150.43.12 0349010005 HSI 90-D6/20 TM2.150.25.8 0349010000 HSI 90-D1/75 TMR3.250.84.20 0350040000 HSI 90-D3/32 TMR3.250.53.13 0350030000 HSI 90-D6/20 TMR3.250.34.10 0350010000 x = wall or masonry thickness Replacement heat shrink sleeves for HSI 90 Repair sleeves for HSI 90 Installation movie 22 cablepipebuildingentry+ 23 Cable sealing system 90 System covers for the connection of cable ducts Cable sealing system 90 System covers for the connection of cable ducts HSI 90 – Sleeve method for smooth and corrugated pipes Item Pipe outer diameter Article code Article number System cover for smooth pipes 75 mm HSI 90-M 75 2206040015 HSI 90-M 90 2206040018 HSI 90-M 90-WR* for Kabuflex: 2206040025 HSI 90-M 110 2225813000 HSI 90-M 110-WR* for Kabuflex: 2206040029 Picture Sleeve method – HSI 90 – M (pipe OD): Cold shrink method – HSI 90 – D/75-KS: • can be used with smooth and corrugated pipes • patented clip ring technology for sealing of corrugated pipes (indicate pipe type and pipe manu facturer, please) • mechanically stable, elastic connection using special sleeves and tightening straps made from stainless steel V4A (AISI 316L) • pressure-tight up to 0.5 bar, depending on the pipe / duct used • for corrugated pipes • shrink-fit method, no tools necessary • stress-free sealing for pressure-sensitive pipes • pressure-tight up to 0.5 bar, depending on the pipe / duct used System cover for smooth pipes 90 mm System cover for corrugated pipes incl. clip rings System cover for smooth pipes 110 mm System cover for corrugated pipes incl. clip rings Cable entries Features and technical data *Kindly indicate pipe manufacturer and pipe type in your order. HSI 90 – Cold shrink sleeves for corrugated pipes Assembly of double wall insert HSI 90-K2 before concreting HSI 90-K2 after concreting: empty ducts will be installed subsequently Item Pipe outer diameter Article code Article number System cover for corrugated pipes 75 mm HSI 90-D 75-KS 2206040001 Picture HSI 90 – Replacement cold shrink sleeves Item For system cover Article code Article number Replacement cold shrink sleeves for HSI 90 HSI 90-D 75-KS KS 235.93.38 0311031050 Connection of corrugated pipes HSI 90-D75 KS Installation movie 24 cablepipebuildingentry+ 25 Cable sealing system 90 Cable entry system Cable sealing system 90 Cable entry system KES-M 90 – Cable entry systems • waterproof concrete stress class 1 Features and technical data Cable entry system – KES-M 90: • pressure-tight ducting system up to 2.5 bar (outer pressure) for connection to the HSI 90-wall inserts • high mechanical stability • elastic connection with special system sleeves and straps made of stainless steel • smooth inner surface for gentle cable feeding • sealing of cables with heat shrink or cold shrink sleeves or rubber press seals • adaptation with common cable ducts possible • also available as role commodity (up to a length of 25 m), extension possible with connection sleeve KES-M 90 HTV KES-M 90-D – Connection to the HSI 90 wall insert Flexible cable entry systems – extensions possible as necessary Cross-section of a concrete wall flexible, pressurestable KES-hose stainless steel hose clamp wrench size13 concrete wall Article code Article number Spiral hose with a smooth inner surface, for gentle cable feeding inner diameter = 90 mm minimum length 1000 mm Hateflex 14090/1000 – Connection sleeve for hose extension / connection of Hateflex 14090 KES-M 90 HTV 2209060100 System cover for pressure-tight connection of spiral hose Hateflex 14090 to HSI 90 wall insert KES-M 90-D 2225810000 Wall insert including blind cover for connecting HSI 90 * system cover to end of spiral hose Hateflex 14090 KES-M 90-KVB 2225811000 Sleeve to be used with interchangeable insert WE 100-z/d to seal cables to end of spiral hose Hateflex 14090 (installation before cables are pulled through) KES-M 90-WE 2225817100 WE 100-z/d 2225817110 Interchangeable insert to be used with sleeve KES-M 90-WE customized according to cables to be installed z= number of cables d= cable diameter Picture * However HRD press seals are not suitable for the use in an assembly frame of the variant KES-M 90-KVB that is not embedded in concrete. 3-ribbed seal extension pipe Item Cable entries Application: wall insert clamping nut system cover cable KES-M 90-KVB – installation in slab heat shrink-fit sleeve rubber sleeve sliding and O-ring x = wall or masonry thickness Installation movie 26 cablepipebuildingentry+ 27 Cable sealing system 90 Cable entry system Cable sealing system 90 Accessories HSI 90 – Accessories Item Article code Article number Connection sleeve for connecting rigid cable ducts OD = 90 mm* to spiral hose Hateflex 14090 KES-M 90-M 90 2225814000 1 set of clip rings to stabilize the corrugated pipe within the sleeve (kindly indicate pipe manufacturer and pipe type in your order) Connection sleeve for connecting rigid cable ducts OD = 110 mm* to spiral hose Hateflex 14090 CR 90 KES-M 90-M 110 1 set of clip rings to stabilize the corrugated pipe within the sleeve (kindly indicate pipe manufacturer and pipe type in your order) CR 110 Rigid pipe section OD = 90 mm with sleeve for connection to spiral hose Hateflex 14090 (tight wall sealing in core drillings when used together with HRD press seals). KES-M 90-R 90 Spacer 2x4 for positioning of hose packages with Hateflex 14090 KES 90-2x4 KA Picture Tool set for pressure-tight strap assembly, consisting of 1 torque 4-20 Nm, ¼ inch, 1 extension 150 mm, ¼ inch, 1 socket for hexagon spanner SWS 13, ¼ inch 28 KES-M-W Article number Flexible pin spanner SLS 6G 0352010000 Flexible pin spanner (buildings with perimeter insulation up to 100 mm) SLS 6GD for Kabuflex: 1630001720 2225813000 Sealing plug for system cover HSI 90-D3/32 (available as single unit or packing unit = 10 pcs) for Kabuflex: 1630001730 2225818000 Picture 0352010100 VS 20 2225819200 VS 32/34 2140403234 Centering tape – set, consisting of 3 pieces elastomer strips 30 x 430 mm HSI-ZB set of 3 2102200700 3-finger sleeve for HSI 90-D3/32 AK.3F.44.13.16.4,2 0307020000 4-finger sleeve for HSI 90-D3/32 AK.4F.44.19.20.7 0308020000 Lubricant 200 g GML 1591000754 Hot-melt tape, cold welding, length 3 m, width approx. 35 mm Hatetherm Scapa 0485 0316010000 Cable cleaner, content: 1000 ml, quick and residue-free evaporation KR M.T.X. 0331010100 Cartridge of 300 ml colour: grey elastic sealant to optimize wall surface when used with sealing flange Sikaflex-11 FC 0505071620 2225819000 HSI 90/KES 90 – Tool set Article code Article code Sealing plug for system cover HSI 90-D6/20 (available as single unit or packing unit = 10 pcs) * additional clip rings CR are necessary to connect corrugated pipes For each pipe connection 2 profile sealing rings are necessary (available from the pipe manufacturer, to be provided on-site). Item Item Cable entries KES-M 90 – Cable entry systems Article number 2128030000 Picture cablepipebuildingentry+ 29 Press seals for cables Standard press seal HRD SG – Universal seal for cables with segment ring technology Press seals for cables Standard press seal HRD SG – Universal seal for cables with segment ring technology Application: HRD SG – Universal seal for cables • Core drilling/ wall sleeve ID Number of cables Cable diameter Article code Article number 80 1 6 – 41 mm HRD 80-SG-1/6-41 2700100108 1 24 – 52 mm HRD 100-SG-1/24-52 2700101000 4 8 – 30 mm HRD 100-SG-4/8-30 2700102000 8 4 – 16,5 mm HRD 100-SG-8/4-16,5 2700103000 HRD 100-SG-2/8-30-3/4-16,5 2700103500 standing seepage water, pressing water, waterproof concrete stress class 1 Features and technical data Universal seal for cables – HRD SG: • absolutely gas- and watertight • sealing width 40 mm • split sealing for retrofit installation • segment ring technology – individual adjusting to installed cable diameters on-site • no loose components • complete with blind plugs • EPDM rubber • pressure plates made of stainless steel V2A (AISI 304L) • sturdy 5 mm pressure plates Picture 100 5 e.g. HRD 80-SG-1/6-41 of which 2 8 – 30 mm of which 3 4 – 16,5 mm 1 24 – 52 mm HRD 104-SG-1/24-52 2700103615 4 8 – 30 mm HRD 104-SG-4/8-30 2700103610 3 10 – 40 mm HRD 125-SG-3/10-40 2700103750 6 6 – 31 mm HRD 125-SG-6/6-31 2700103800 10 4 – 16,5 mm HRD 125-SG-10/4-16,5 2700103850 1 12 – 75 mm HRD 150-SG-1/12-75 2700103996 1 75 – 110 mm HRD 150-SG-1/75-110 2700103998 3 22 – 54 mm HRD 150-SG-3/22-54 2700104000 6 8 – 35 mm HRD 150-SG-6/8-35 2700105000 9 6 – 25 mm HRD 150-SG-9/6-25 2700106000 HRD 150-SG-4/8-30-6/4-16,5 2700106500 HRD 200-SG-3/6-54-4/6-26 2700107000 125 HRD 150-SG installed in fibre cement wall sleeves HRD 150-SG – 6/8-35 – individual adjusting to diameters of cables Press seals 104 e.g.HRD 150-SG-3/22-54 150 10 of which 4 8 – 30 mm of which 6 4 – 16,5 mm 7 of which 3 6 – 54 mm of which 4 6 – 26 mm e.g.HRD 200-SG-3/6-54-4/6-26 200 15 Installation movie HRD 100-SG-4/8-30 30 HRD 200-SG-7/10-32-8/3,5-16,5 of which 7 10 – 32 mm of which 8 3,5 – 16,5 mm 2700108000 Installation movie HRD 150-SG-3/22-54 cablepipebuildingentry+ 31 Press seals for cables Individual press seal (closed and split), sealing width 30 mm Press seals for cables Individual press seal (closed and split), sealing width 30 mm, EPDM with V2A (AISI 304L) Application: Individual press seal closed • Core drilling/ wall sleeve ID standing seepage water, pressing water, waterproof concrete stress class 1 Features and technical data Individual press seal HRD: • absolutely gas- and watertight • sealing width 30 mm • closed or split • different outer diameters can be manufactured exactly to customers‘ requirements • easy to mount • optionally available with overlapping flange (F) or eccentric • suitable for one or more cables • for core drillings/wall sleeves from diameter 25 mm • suitable for sealing rigid cable ducts • EPDM, NBR or silicone rubber • pressure plates made from stainless steel V2A (AISI 304L), optionally V4A (AISI 316L) • sturdy 5 mm pressure plates Optimal Max. possible application application range range diameter diameter * Closed design Article code Article number 50 mm 0 – 25 mm 0 – 26 mm HRD 50-1-1/d 2701210001 60 mm 0 – 32 mm 0 – 36 mm HRD 60-1-1/d 2701220001 70 mm 0 – 40 mm 0 – 46 mm HRD 70-1-1/d 2701230001 80 mm 0 – 50 mm 0 – 56 mm HRD 80-1-1/d 2701240001 100 mm 0 – 63 mm 0 – 76 mm HRD 100-1-1/d 2701250010 125 mm 63 – 90 mm 0 – 101 mm HRD 125-1-1/d 2701260001 150 mm 90 – 112 mm 0 – 125 mm HRD 150-1-1/d 2701270010 200 mm 110 – 162 mm 0 – 171 mm HRD 200-1-1/d 2701280010 250 mm 160 – 210 mm 0 – 214 mm HRD 250-1-1/d 2701290001 Customized diameters available Picture d = cable diameter Press seals * For maximum cable configuration please refer to table on page 32. Individual press seal split Core drilling/ wall sleeve ID HRD 150-1G sealing several cables per core drilling / wall sleeve HRD 200-1G installed in a steel pipe Configuration table Number = Z cables/pipes Core drilling Core drilling Core drilling Core drilling Core drilling Core drilling Core drilling diameter HRD 50 diameter HRD 80 diameter HRD 100 diameter HRD 125 diameter HRD 150 diameter HRD 200 diameter HRD 250 Optimal Max. possible application application range range diameter diameter * Split design Article code Article number 50 mm 0 – 25 mm 0 – 26 mm HRD 50-1G-1/d 2705010001 60 mm 0 – 32 mm 0 – 36 mm HRD 60-1G-1/d 2705020001 70 mm 0 – 40 mm 0 – 46 mm HRD 70-1G-1/d 2705030001 80 mm 0 – 50 mm 0 – 56 mm HRD 80-1G-1/d 2705040001 100 mm 0 – 63 mm 0 – 76 mm HRD 100-1G-1/d 2705050001 125 mm 63 – 90 mm 0 – 101 mm HRD 125-1G-1/d 2705060001 150 mm 90 – 112 mm 0 – 125 mm HRD 150-1G-1/d 2705070001 200 mm 110 – 162 mm 0 – 171 mm HRD 200-1G-1/d 2705080001 250 mm 160 – 210 mm 0 – 214 mm HRD 250-1G-1/d 2705090001 Customized diameters available Picture d = cable diameter * For maximum cable configuration please refer to table on page 32. Cable/pipe diameter = dmax 1 26 56 76 101 125 171 214 2 16 31 41 53 66 91 116 3 14 28 37 49 60 84 107 4 12 24 32 43 53 74 95 5 8 21 28 38 47 65 84 6 5 18 25 33 42 58 75 7 - 15 21 32 39 56 73 Further variants: blind insert, article code: e.g. HRD 117-1-0 split, eccentric sealing insert, article code: e.g. HRD 156-1G-1/45-ex-23 All individual press seal-variants also available with overlapping flange. Further sizes up to diameter 1,500 mm available on short notice upon request. Installation instructions 32 cablepipebuildingentry+ 33 Press seals for cables Individual press seal (closed and split), sealing width 60 mm Press seals for cables Individual press seal (closed and split), sealing width 60 mm, EPDM with V2A (AISI 304L) Individual press seal closed Application: • standing seepage water, pressing water, high stress (chemical, thermal), difficult installation conditions, waterproof concrete stress class 1 Features and technical data Individual press seal HRD: • absolutely gas- and watertight • sealing width 60 mm • closed or split • different outer diameters can be manufactured exactly to customers‘ requirements • easy to mount • optionally available with overlapping flange (F) or eccentric • suitable for one or more cables • for core drillings/wall sleeves from diameter 25 mm • EPDM, NBR or silicone rubber • pressure plates made from stainless steel V2A (AISI 304L), optionally V4A (AISI 316L) • sturdy 5 mm pressure plates Core drilling/ wall sleeve ID Optimal application range diameter Max. possible application range diameter * Closed design Article code Article number 50 mm 0 – 25 mm 0 – 26 mm HRD 50-2-1/d 2703210001 60 mm 25 – 32 mm 0 – 36 mm HRD 60-2-1/d 2703220001 70 mm 25 – 40 mm 0 – 46 mm HRD 70-2-1/d 2703230001 80 mm 25 – 50 mm 0 – 56 mm HRD 80-2-1/d 2703240001 100 mm 25 – 63 mm 0 – 76 mm HRD 100-2-1/d 2703250001 125 mm 63 – 90 mm 0 – 101 mm HRD 125-2-1/d 2703260001 150 mm 90 – 112 mm 0 – 125 mm HRD 150-2-1/d 2703270001 200 mm 110 – 162 mm 0 – 171 mm HRD 200-2-1/d 2703280001 250 mm 160 – 210 mm 0 – 214 mm HRD 250-2-1/d 2703290001 Customized diameters available Picture d = cable diameter Press seals * For maximum cable configuration please refer to table on page 34. Individual press seal split HRD 100-2-0 blind insert HRD 150-2G-2/18-2/27 Configuration table Number = Z Cables/pipes Core drilling diameter HRD 50 Core drilling diameter HRD 80 Core drilling Core drilling Core drilling Core drilling Core drilling diameter HRD 100 diameter HRD 125 diameter HRD 150 diameter HRD 200 diameter HRD 250 Core drilling/ wall sleeve ID Optimal application range diameter Max. possible application range diameter * Split design Article code Article number 50 mm 0 – 25 mm 0 – 26 mm HRD 50-2G-1/d 2706010001 60 mm 25 – 32 mm 0 – 36 mm HRD 60-2G-1/d 2706020001 70 mm 25 – 40 mm 0 – 46 mm HRD 70-2G-1/d 2706030001 80 mm 25 – 50 mm 0 – 56 mm HRD 80-2G-1/d 2706040001 100 mm 25 – 63 mm 0 – 76 mm HRD 100-2G-1/d 2706050001 125 mm 63 – 90 mm 0 – 101 mm HRD 125-2G-1/d 2706060001 150 mm 90 – 112 mm 0 – 125 mm HRD 150-2G-1/d 2706070010 200 mm 110 – 162 mm 0 – 171 mm HRD 200-2G-1/d 2706081000 250 mm 160 – 210 mm 0 – 214 mm HRD 250-2G-1/d 2706090001 Customized diameters available Picture d = cable diameter * For maximum cable configuration please refer to table on page 34. Cable/pipe diameter = dmax 1 26 56 76 101 125 171 214 2 16 31 41 53 66 91 116 3 14 28 37 49 60 84 107 4 12 24 32 43 53 74 95 5 8 21 28 38 47 65 84 6 5 18 25 33 42 58 75 7 - 15 21 32 39 56 73 Further variants: blind insert, article code: e.g. HRD 117-2-0 split, eccentric sealing insert, article code: e.g. HRD 137-2G-1/39-ex-20 All individual press seal-variants also available with overlapping flange. Further diameters up to 1,500 mm available on short notice upon request. Installation instructions 34 cablepipebuildingentry+ 35 Wall sleeves Renovation wall sleeve SFR Wall sleeves Renovation wall sleeve SFR Renovation wall sleeve SFR Application: Medium pipe non-standing seepage water Wall sleeve Wall sleeve ID OD Features and technical data Renovation wall sleeve SFR: • for subsequent installation in wall break-throughs, core drillings or rectangular openings • breaking resistant, dimensionally stable • can easily be shortened to required length • suitable for all wall types except for waterproof concrete • roughened surface will homogeneously connect to mortar • compact design allows for smallest possible drillings / break throughs • dimensions: SFR 100: ID = 100 mm, OD = 110 mm SFR 150: ID = 150 mm, OD = 162 mm SFR 200: ID = 200 mm, OD = 214 mm Roughened surface 36 wall thickness 4,5 u. 6 mm min. 20 mm mortar all around interior diam. plastic-modified, bitumin thick coating with rounded groove Optimum application range OD Maximum Minimum Length poss. area of drilling application OD* Article code Article number 100 mm 110 mm 0 – 63 mm 0 – 76 mm 150 mm 300 mm SFR 100/300 0930000050 100 mm 110 mm 0 – 63 mm 0 – 76 mm 150 mm 500 mm SFR 100/500 0930000080 100 mm 110 mm 0 – 63 mm 0 – 76 mm 150 mm 1000 mm SFR 100/1000 0930000110 150 mm 162 mm 90 – 112 mm 0 – 125 mm 200 mm 300 mm SFR 150/300 0930000140 150 mm 162 mm 90 – 112 mm 0 – 125 mm 200 mm 500 mm SFR 150/500 0930000160 150 mm 162 mm 90 – 112 mm 0 – 125 mm 200 mm 1000 mm SFR 150/1000 0930000180 200 mm 214 mm 110 – 162 mm 0 – 171 mm 250 mm 300 mm SFR 200/300 0930000220 200 mm 214 mm 110 – 162 mm 0 – 171 mm 250 mm 500 mm SFR 200/500 0930000240 200 mm 214 mm 110 – 162 mm 0 – 171 mm 250 mm 1000 mm SFR 200/1000 0930000260 Picture SFR 100/500 Press seals • * For maximum cable configuration please refer to table on page 34. SFR - installation according to DIN 18195, part 4 cablepipebuildingentry+ 37 Wall sleeves Special solutions Wall sleeves Special solutions Special solutions before Special solutions after Rectangular split flange for several cable penetrations Split fibre cement wall sleeve FZR-G Fixed and loose flange HRD (D)-FUFA for sealing according to DIN 18195 part 6 Slanted core drilling in porous wall Fixed/loose flange with slanted empty hose connection and surface sealing Split multiple HRD flange HRD (2xD)-FG Closed HRD flange HRD (D)-F Entry of high-voltage cables and cable ducts have to be subsequently sealed in a shaft wall Split fixed/loose flange according to DIN 18195 Two-level fixed/loose flange HRD (D)-FUFFA for sealing according to DIN 18195 part 5 Double wall insert HSI 150-K2F/X for sealing according to DIN 18195 part 6 Press seals Existing rectangular opening has to be subsequently sealed 38 cablepipebuildingentry+ 39 Earthings Entries Earthings Entries HEA / HEA-E – Entry for earthing in concrete Application: waterproof concrete stress class 1 Item Features and technical data Entry for earthing in concrete – HEA / HEA-E: water barrier Wassersperre Ø 25 mm protective cover Schalungsscheibe Ø 72 mm • conductor core Ø 25 mm with a threaded connection on both sides M12, made of stainless steel V4A (AISI 316L), HEA-E also available with connecting thread M16 • pressure-tight water barrier (profiled rubber flange, NBR) • contact plates Ø 72 mm made of stainless steel V4A (AISI 316L) • protective covers made of PE with four nail holes • HEA wall thickness 70-200 mm • HEA-E wall thickness > 200 mm • conductor core for HEA-E connection via M16 bolts, galvanised • no twisting after installation in concrete • according to DIN 18014, DIN EN 62305-3 VDE 0185-305-3 (with lightning protection) 10 mm thread M12 Gewinde M12 Article number HEA-M12/70 1700010070 HEA-M12/100 1700010100 HEA-M12/150 1700010150 HEA-M12/200 1700010200 HEA-E-M12/X 1700020010 HEA-E-M16/X 1700020020 Picture e.g. HEA-M12/100 e.g. HEA-E-M12/240 X = wall thickness in mm Increments of 10 mm possible Installation instructions HEA-IS-M12 – Insulated feedthrough for station earthing Application: • Entry for earthing connections made of stainless steel V4A (AISI 316L), connection M 12 on both sides, with water barrier and protective foils, for wall thickness 70 mm Entry for earthing connections made of stainless steel V4A (AISI 316L), connection M 12 on both sides, with water barrier and protective covers, for wall thickness 100 mm Entry for earthing connections made of stainless steel V4A (AISI 316L), connection M 12 on both sides, with water barrier and protective covers, for wall thickness 150 mm Entry for earthing connections made of stainless steel V4A (AISI 316L), connection M 12 on both sides, with water barrier and protective covers, for wall thickness 200 mm Entry for earthing connections made of stainless steel V4A (AISI 316L), connection M 12 on both sides, with water barrier and protective covers, available for wall thicknesses 210 - 500 mm Entry for earthing connections made of stainless steel V4A (AISI 316L), connection M 16 on both sides, with water barrier and protective covers, available for wall thicknesses 210 - 500 mm Article code waterproof concrete stress class 1 Features and technical data water barrier Wassersperre Insulated entry for substation construction – HEA-IS-M12: Ø 72 mm • conductor core Ø 25 mm with a threaded connection on both sides M12, made of stainless steel V2A (AISI 304L) • pressure-tight water barrier (profiled rubber flange, EPDM) • contact plates Ø 72 mm made of stainless steel V2A (AISI 304L) • with protective cover • minimum wall thickness HEA-IS: 70 mm • according to VDE 0101, EN 50522 • short-circuit tested Ø 25 mm protective cover Schutzabdeckung thread M12 Gewinde M12 min. wall thickness7070mm mm mind. Wandstärke Item Article code Article number Feedthrough for earthing connections made of stainless steel V2A (AISI 304L), connection M12 on both sides, with water barrier and protective cover (HEA-IS-M12) for wall thickness 100 mm HEA-IS-M12/100 1710020100 Feedthrough for earthing connections made of stainless steel V2A (AISI 304L), connection M12 on both sides, with water barrier and protective cover (HEA-IS-M12) for wall thickness 150 mm HEA-IS-M12/150 1710020150 Feedthrough for earthing connections made of stainless steel V2A (AISI 304L), connection M12 on both sides, with water barrier and protective cover (HEA-IS-M12) for wall thickness 200 mm HEA-IS-M12/200 1710020156 Feedthrough for earthing connections made of stainless steel V2A (AISI 304L), connection M12 on both sides, with water barrier and protective cover (HEA-IS-M12) for wall thickness 250 mm HEA-IS-M12/250 1710020157 Article code Article number HEA-PK-M12/X 1700030010 HEA-PK-M16/X 1700030020 Picture HEA-IS-M12/100 Extra • Increments of 10 mm possible HEA-PK-M12 – Earthing connection and entry Application: • waterproof concrete stress class 1 Item Features and technical data 40 thread GewindeM12 M12 oder M16 or M16 Schalungsscheibe contact plate Increments of 10 mm possible Ø 25 mm • conductor core Ø 25 mm with a threaded connection on both sides M12/M16, made of stainless steel V4A (AISI 316L) • terminal lug with cross clamp 70 x 70 mm made of steel St37, galvanised • pressure-tight water barrier (profiled rubber flange, NBR) • contact plates Ø 72 mm made of stainless steel V4A (AISI 316L) • protective covers made of PE with four nail holes • minimum wall thickness 200 mm • conductor core connection with M16 threaded bolts, galvanised • according to DIN 18014, DIN EN 62305-3 VDE 0185-305-3 (with lightning protection) water barrier Wassersperre Ø 72 mm Earthing connection and entry – HEA-PK-M12 / HEA-PK-M16: cross-clamp for connecting strip Kreuzklemme irons up to zum Anschluss von 40 x Bandeisen 4 mm 40 x 4 mm rod mm Rd.8-12 8/12 mm Entry for earthing connections made of stainless steel V4A (AISI 316L), connection M12 on both sides, with terminal lug and cross clamp, available for wall thicknesses 150 - 500 mm, with water barrier and protective covers Entry for earthing connections made of stainless steel V4A (AISI 316L), connection M16 on both sides, with terminal lug and cross clamp, available for wall thicknesses 150 - 500 mm, with water barrier and protective covers thread M12 Gewinde M12 or M16 oder M16 Picture X = wall thickness in mm Short circuit-proof up to 10 KA/1s (VDE 0101/E DIN EN 50522) min.mind. wallWandstärke thickness150 150 mmmm cablepipebuildingentry+ 41 Earthings Fixed points Earthings Fixed points HEA-P-M12 / HEA-P-M16 – Fixed point with cross clamp Application: • waterproof concrete stress class 1 Features and technical data contact plate Schalungsscheibe Ø 72 mm • conductor core, Ø 25 mm with threaded connection M12 /M16 made of stainless steel V4A (AISI 316L) • cross clamp 70 x 70 mm with threaded bolt M12 or M16 galvanised • contact plate Ø 72 mm made of stainless steel V4A (AISI 316L) • protective cover made of PE with four nail holes • minimum wall thickness 200 mm • distance between formwork and earth connection approximately 120 mm • according to DIN 18014, DIN EN 62305-3 VDE 0185-305-3 (with lightning protection) Ø 25 mm Fixed point with cross clamb – HEA-P-M12 / HEA-P-M16: cross-clamp for Kreuzklemme connecting strip zum Anschluss irons up to von Bandeisen bisx40 x 4 mm 40 4 mm Rd. 8/12 mm rod 8-12 mm Ø 25 mm Ø 25 mm Ø 72 mm Ø 72 mm Fixed point with weld groove – HEA-A-M12: Schweißnut weld groove Schweißnut Gewinde M12 HEA-P-M12 1700100010 Fixed point with screwed-on crossclamp for the connection in concrete, connection M16, made of stainless steel V4A (AISI 316L), with protective cover, installation length = 120 mm HEA-P-M16 1700100020 HEA-P-M12 Item Article code Article number Fixed point made of stainless steel V2A (AISI 304L) with weld groove made of steel St 37, conductor core Ø 25 mm, connection M12, for distances between formwork and the core iron 50 mm HEA-A-M12/50 1700300500 Fixed point made of stainless steel V2A (AISI 304L) with weld groove made of steel St 37, conductor core Ø 25 mm, connection M12, for distances between formwork and the core iron 70 mm HEA-A-M12/70 Picture HEA-A-M12/50 1700300520 HEA-A-M12/70 Extra thread M12 Gewinde Abstand zur Armierung distance tozur reinAbstand mind. Wandstärke forcement 50 mm 100 mm Armierung abhängig von der Beton-Expositionsklasse min. wall thickness100 100 mm mind. Wandstärke mm abhängig von der depending on exposure Beton-Expositionsklasse class of concrete Fixed point with welded or clamped connection Application: waterproof concrete stress class 1 Features and technical data Fixed point with welded or clamped connection – HEA-S-M12 / HEA-S-M16: Fixed point with screwed-on crossclamp for the connection in concrete, connection M12, made of stainless steel V4A (AISI 316L), with protective cover, installation length = 120 mm Picture HEA-A-M12 – Fixed point with weld groove Features and technical data • Article number min.mind. wallWandstärke thickness 200 200mm mm waterproof concrete stress class 1 • conductor core, Ø 25 mm with threaded connection M12 made of stainless steel V2A (AISI 304L) • fixed point with welded groove made of steel St37 to connect with 10 – 12 mm round steel • contact plate Ø 72 mm made of stainless steel V2A (AISI 304L) • protective foil green transparent • distance between formwork and the core iron 50 mm (HEA-A-M12/50) or 70 mm (HEA-A-M12/70) • short-circuit tested according to VDE 0101, EN 50522 Article code thread M12 Gewinde M12 or M16 oder M16 Application: • Item contact plate Schalungsscheibe Item Article code Article number Fixed point made of stainless steel V4A (AISI 316L) with screwed-on steel rod made of steel St 37, Ø 12 mm, connection M12, for welded or clamped connection in concrete HEA-S-M12 1700080010 Fixed point made of stainless steel V4A (AISI 316L) with screwed-on steel rod made of steel St 37, Ø 12 mm, connection M16, for welded or clamped connection in concrete HEA-S-M16 1700080020 Picture 42 Ø 25 mm Ø 72 mm cross-clamp for • conductor core, Ø 25 mm with threaded connection M12/M16 made of stainless steel V4A (AISI 316L) • steel rod Ø 12 mm made of steel St37 for welded or clamped connection in concrete • contact plate Ø 72 mm made of stainless steel V4A (AISI 316L) • protective covers made of PE with four nail holes • according to DIN 18014, DIN EN 62305-3 VDE 0185-305-3 (with lightning protection) Kreuzklemme connecting strip zum Anschluss ironsBandeisen up to von bis 40 x 5 mm 40 x 5 mm Rd. rod 8/12 8-12mm mm nicht im Liefernot included umfang enthalten HEA-S-M12 thread M12 Gewinde M12 cablepipebuildingentry+ 43 Earthings Entries Earthings Entries HEA-N – Entry for subsequent installation Application: • waterproof concrete stress class 1 Item Article code Article number Picture Features and technical data Entry for subsequent installation – HEA-N: Abdichtung sealing • M16 threaded rod made of stainless steel V4A (ASI 316L) with sealing on both sides • contact plate Ø 72 mm made of stainless steel V4A (AISI 316L) • terminal lug with cross clamp for FL 40 x 4 mm or rod 10 – 12 mm • suitable for wall thicknesses up to 600 mm, bigger wall thicknesses on request • suitable for bore holes Ø 18 – 22 mm • according to DIN 18014, DIN EN 62305-3 VDE 0185-305-3 (with lightning protection) Entry for earthing connections, M16, stainless steel V4A (AISI 316L), HEA-N-M16/200 for wall thicknesses up to 200 mm for subsequent installation 1700050010 Entry for earthing connections, M16, stainless steel V4A (AISI 316L), HEA-N-M16/600 for wall thicknesses up to 600 mm for subsequent installation 1700050020 threaded rod M16 Gewindestange cross-clamp for Kreuzklemme connecting strip zum Anschluss irons up to von Bandeisen mm 40 xx 44 mm 3,5mm mm 30 xx 3,5 Rd. 10-12 10 - 12 mm rod mm mind. 200200 mm mm min. Wandstärke wall thickness Entry for earthing connections, M16, stainless steel V4A (AISI 316L), for walls with perimeter insulation up to 200 mm, HEA-ND-M16/400 for wall thicknesses up to 400 mm for subsequent installation HEA-N-M16/X 1700050120 X = wall thickness in mm HEA-W – Entry for “black tank” Application: standing seepage water, pressing water, waterproof concrete stress class 1 Features and technical data Entry for „black tank“ – HEA-W: • for buildings with watertight external sealing according to DIN 18195 part 6, manufactured according to DIN 18195 part 9 (fixed/loose flange, Ø 210 mm) • conductor core Ø 25 mm made of stainless steel V4A (AISI 316L) with threaded connection on both sides M12/M16 and additional cross clamp M20 as an external connection made of stainless steel V4A (ASI 316L) • conductor core connection with M16 threaded bolts and lock nuts, galvanised • contact plates Ø 72 mm made of stainless steel V4A (AISI 316L) • protective covers made of PE with four nail holse • minimum wall thickness 180 mm • according to DIN 18014, DIN EN 62305-3 VDE 0185-305-3 (with lightning protection) inside of building Gebäudeaußenseite fixed flange Festflansch Losflansch Gebäudeaußenseite loose flange Festflansch bolt 30 x 30 mm Bolzen 30 x 30 mm Losflansch insulated isoliert Dichtbahn Dichtbahn Bolzen 30 x 30 mm isoliert Bolzen 30mm mm Bolzen30Øx25 isoliert cross-clamp for Kreuzklemme connecting strip zum Anschluss ironsvon upBandeisen to 40 x 4 mm 40 xbis 4 mm Kreuzklemme Rd. 8-12 mm rod Anschluss 8-12 mm zum Losflansch Dichtbahn Kreuzklemme zum Anschluss von Bandeisen von Bandeisen Armierungsstahl reinforcing steel bis 40 x 4 mm bis 40 x 4 mm Rd. 8-12 mm Rd. 8-12 mm Anschlussbolzen M12 oder M16 Bolzen Ø 25 mm Gebäudeinnenseite thread M12 Gewinde M12 M16 oroder M16 Festflansch Gewinde M12 Bolzen 30M16 x 30 mm oder isoliert Article code Article number Entry HEA-W/x for buildings with watertight external sealing according to DIN 18195 part 6, manufactured according to DIN 18195 part 9 (fixed/ loose flange, Ø 210 mm), internal connection M12, cross clamp with threaded bolt M20 (min. wall thinkness 180 mm) HEA-W-M12/X 1700040015 Entry HEA-W/x for buildings with watertight external sealing according to DIN 18195 part 6, manufactured according to DIN 18195 part 9 (fixed/ loose flange, Ø 210 mm), internal connection M16, cross clamp with threaded bolt M20 (min. wall thickness 180 mm) HEA-W-M16/X 1700040020 Anschlussbolzen M12 oder M16 X = wall thickness in mm Gewinde M12 oder Ø M16 Bolzen 25 mm mind. Wandstärke 180 mmmind. Wandstärke 180 mm Gewinde M12 oder M16 HEA-EW – Entry for double wall / element wall Item Armierungsstahl mind. Wandstärke 180 mm Entry for double wall /element wall – HEA-EW-M12: Wassersperre Wassersperre Ø 25 mm Schalungsscheibe Schalungsscheibe Schalungsscheibe protective cover Ø 25Ømm 25 mm Ø 72 mm Wassersperre water barrier Ø 72Ømm 72 mm HEA-W-M12/X mind. Wandstärke 180 180 mm mm min. wall thickness Kreuzklemme zum Anschluss von Bandeisen bis 40 x 4 mm Rd. 8-12 mm Wassersperre Gewinde Gewinde M12 M12 Wassersperre thread M12 Gewinde M12 Entry for earthing connections made of stainless steel V4A (AISI 316L), connection M12 on both sides, with 3 water barriers and protective covers (min. wall thickness 170 mm) Schalungsscheibe Schalungsscheibe mind. mind. Wandstärke Wandstärke 170 170 mmmm Article code Article number HEA-EW-M12/170 1700020500 HEA-EW-M12/180 1700020510 HEA-EW-M12/190 1700020520 HEA-EW-M12/200 1700020530 HEA-EW-M12/240 1700020570 HEA-EW-M12/250 1700020580 HEA-EW-M12/300 1700020630 HEA-EW-M12/360 1700020690 HEA-EW-M12/400 1700020695 Picture HEA-EW-M12/X Ø 25 mm Ø 25 mm mm mm min.mind. wallWandstärke thickness170170 Ø 72 mm Ø 72 mm Picture Armierungsstahl Armierungsstahl Features and technical data 44 Anschlussbolzen M12 oder M16 bolt ØØ25 mm Bolzen 25 mm Gebäudeaußenseite waterproof concrete stress class 1 • conductor core Ø 25 mm with a threaded connection on both sides M12 made of stainless steel V4A (AISI 316L) • conductor core connection with M16 threaded bolts, galvanised • 2 water barriers (profiled rubber flange, NBR) and 1 additional seal on the threaded bolt, the position of which can be adapted on site • contact plates Ø 72 mm made of stainless steel V4A (AISI 316L) • protective covers made of PE with four nail holes • minimum wall thickness 170 mm • according to DIN 18014, DIN EN 62305-3 VDE 0185-305-3 (with lightning protection) Anschlussbolzen connecting bolt M12 oder M16 Gebäudeinnenseite M12 or M16 Gebäudeinnenseite Gebäudeaußenseite Festflansch membrane Dichtbahn Losflansch Application: • Gebäudeinnenseite outside of building Item Extra • Gewinde M12 Gewinde M12 mind. Wandstärke 170170 mmmm mind. Wandstärke cablepipebuildingentry+ 45 Earthings Entries Earthings Entries HEA-F/HEA-PF – Entry for flexible earthing connections Application: • waterproof concrete stress class 1 Features and technical data Entry for flexible earthing connections – HEA-F (insulated) / HEA-PF: steel cable Stahlseil Ø 10 Ø mm10 mm Ø 25 mm Schalungsscheibe protective cover Ø 25 mm GewindeM12 M12 thread oder M16 or M16 100 mm Ø 72 mm Ø 72 mm • conductor core Ø 25 mm made of stainless steel V4A (AISI 316L) with threaded connection on both sides M12 or M16 • pressure-tight water barrier (profiled rubber flange, NBR) • contact plate Ø 72 mm made of stainless steel V4A (AISI 316L) • protective covers made of PE with four nail holes • for wall thicknesses up to 600 mm, bigger wall thicknesses on request • HEA-F: Cu ground strap 50 mm2, finely stranded, insulated • HEA-PF: steel cable dia. 10 mm, galvanized. Can be fastened to reinforcement bars with cross clamp Z-K40-St37 fvz • according to DIN 18014, DIN EN 62305-3 VDE 0185-305-3 (with lightning protection) 100 mm Item Article code Article number Flexible, insulated earthing entry and copper (Cu) ground strap 50 mm² with connecting thread M12 for wall thicknesses up to 600 mm HEA-F-M12/600 1700070010 Flexible, insulated earthing entry and copper (Cu) ground strap 50 mm² with connecting thread M16 for wall thicknesses up to 600 mm HEA-F-M16/600 1700070020 Flexible earthing entry with steel cable Ø 10 mm galvanised and connecting thread M12 for wall thicknesses up to 600 mm HEA-PF-M12/600 1700060010 Flexible earthing entry with steel cable Ø 10 mm galvanised and connecting thread M16 for wall thicknesses up to 600 mm HEA-PF-M16/600 1700060020 Picture thread GewindeM12 M12 oder M16 or M16 min. thickness 150 mind.wall Wandstärke 150 mmmm max. wall thickness max. Wandstärke 600600 mmmm type: HEA-PF Accessories Accessories Connection bolt M12 with washer, lock washer and screw nut made of material St37 zinc-plated Connection bolt M16 with washer, lock washer and screw nut made of material St37 zinc-plated Connection bolt M12 with washer, lock washer and screw nut made of stainless steel V4A (AISI 316L) Connection bolt M16 with washer, lock washer and screw nut made of stainless steel V4A (AISI 316L) Article number Z-B-M12-St37 1700110010 Z-B-M16-St37 1700110020 Z-B-M12-V4A 1700110040 Z-B-M16-V4A 1700110050 Four-wire connector with screwed-on threaded bolt M12 made of material St37 zinc-plated Z-KG-M12-fvz Four-wire connector with screwed-on threaded bolt M12 made of stainless steel V4A (AISI 316L) Z-KG-M12-V4A 1700120010 Four-wire connector with screwed-on threaded bolt M16 made of stainless steel V4A (AISI 316L) Z-KG-M16-V4A 1700120020 Z-KG-D-M12-V4A 1700130010 Z-KG-D-M16-V4A 1700130020 Four-wire connector with screwed-on threaded bolt M12 made of stainless steel V4A (AISI 316L) for buildings with perimeter insulation up to 80 mm Four-wire connector with screwed-on threaded bolt M16 made of stainless steel V4A (AISI 316L) for buildings with perimeter insulation up to bis 80 mm 46 Article code Article code Article number Jumper cable strap for connecting foundation earthing lines in the vicinity of expansion joints, length 180 mm, material: Cu 50 mm² (finely-stranded) Z-ÜB-M12-Cu 1700190010 Flexible bonding for connecting foundation earthing lines in the vicinity of expansion joints and for connecting metal cladding, length 300 mm, material: Cu 16 mm² (multi-stranded) Z-ÜS-M12-Cu/300 1700200010 Terminal lug for connecting earthing conductors, equipotential busbar or lightning protection technology, lug stainless steel V4A (AISI 316L), with connecting screw M12 Z-AL30-M12 1700170010 Terminal lug for connecting earthing conductors, equipotential busbar or lightning protection technology, lug stainless steel V4A (AISI 316L), with connecting screw M16 Z-AL40-M16 1700170020 Hot-melt tape, cold-welding, length 3 m, width approximately 35 mm, eminently suitable as corrosion protection for earthing connectors Hatetherm Scapa 0485 0316010000 Picture Picture Z-B-M12-St37 Extra Item Item 1700120030 Z-KG-M12-V4A Z-KG-D-M12 Connection terminal 70 x 70 mm made of St37 zinc-plated for flat belt 40 x 4 mm or circular conductor connection 8 – 12 mm Z-K40-St37-fvz 1700140010 Connection terminal 70 x 70 mm made of stainless steel V4A (AISI 316L) for flat belt 40 x 4 mm or circular conductor connection 8 – 12 mm Z-K40-V4A 1700140020 Z-K40-V4A cablepipebuildingentry+ 47 Fire protection for cables HVS / HSS – gas- and watertight firewall S 90 for installation in wall insert HSI 150, wall sleeves and core drillings DIB Z-19 T-approv .1 a purs 5-1906 ( l . to D HSS) Z-19 IN 41 .1 0 purs 5-1792 ( 2-9 . to D HVS ) IN 41 02-9 Features and technical data Firewall S 90 – HVS / HSS: • fire protection S 90 • for core drillings 70 – 200 mm diameter • for plastic wall sleeves 80 – 200 mm diameter • for wall inserts HSI 150 (maximum package 2 x 6) • insulation thickness 280 mm • as of wall thickness 150 mm • no additional wall construction necessary • no limitation of individual cable diameters • pads assembly possible from one side • high flexibility for subsequent insertion • no additional coating of cables necessary HSS – installation fire-stop pads in wall insert HSI 150-K2, sealing with system cover or SEGMENTO Fire protection for cables HVS / HSS – gas- and watertight firewall S 90 for installation in wall insert HSI 150, wall sleeves and core drillings HVS/HSS – fire protections set and tools Item Core drilling/ wall sleeve diameter Article code Article number Picture Approval no: Z-19.15-1906 – fire protection S 90, gastight Gastight fire protection set in connection with HRD consisting of: fire-stop pads 2x HVS-K250, 3x HVS-KB-60, label, stainless steel belt Up to diameter 100 mm HSS-100-KB/FR-HRD 2600030002 Gastight fire protection set in connection with HRD consisting of: fire-stop pads 2x HVS-K400, 3x HVS -K250, 3x HVS-KB-60, 1 x label, stainless steel belt Up to diameter 150 mm HSS-150-KB/FR-HRD 2600030003 Approval no: Z-19.15-1792 – fire protection S 90 HSS – installation in core drillings with HRD press seals Fire protection set consisting of: fire-stop pads 3x HVS -K250/2, 5x HVS-KB-60, 1x label, 2x stainless steel belts Up to diameter 100 mm HVS-KK 100 2600010005 Fire protection set consisting of: fire-stop pads 2x HVS-K400, 5x HVS -K250/2, 6x HVS-KB-60, 1x label, 2x stainless steel belts Up to diameter 150 mm HVS-KK 150 2600010006 Fire protection set consisting of: fire-stop pads 2x HVS-K720, 2x HVS-K400, 5x HVS -K250/2, 8x HVS-KB-60, 1x label, 4x stainless steel belts Up to diameter 200 mm HVS-KK 200 2600010007 HVS/HSS-MB 2600024100 Application table HSS Fitting panel, for close-fitting installation of HVS/HSS fire-stop pads System HSS HRD 150/160 for HSI 150 SEG = SEGMENTO D / DG System cover Core drilling/wall sleeve (with HRD) Wall thickness in mm ≥ 150 ≥ 240 ≥ 240 ≥ 150 Cable configuration results from sealing system selection Total insulation thickness in mm 280 Size in mm after package formation HSI 150 (max. 2-row, 6 pieces in a row) Tightness in bar up to 2.5 0.5 up to 2.5 up to 5 Insulation thickness in mm 200 200 200 50 Cable type all cables and cross sections except for wave guides – no cable cross section limitation Installation in masonry, concrete or aerated concrete walls Comment configuration is limited by the sealing systems Universal fire-resistant sealing for cable entry HSI 150 Item 440 Extra Delivery without HRD rubber press seal. 440 Sealing Article code Article number Picture 280 Approval no: Z-19.15-1906 – fire protection S 90 Ø 70 (80) – 200 Fire protection set consisting of: fire-stop pad 1x HVS-K720, 1x HVS-K400, 4x HVS -K250/2, 4x HVS-KB-60, label, stainless steel belt SEGMENTO Systemdeckel HSS-150/SEG/D/DG 2600030000 Fire protection set consisting of: fire-stop pads 2x HVS-K400, 3x HVS-K250, 3x HVS-KB-60, label, stainless steel belt HRD-press seal HSS-150/HRD 2600030001 Delivery without HRD rubber press seal, SEGMENTO respectively system cover. 48 cablepipebuildingentry+ 49 Roof entries SHD – swan neck roof entry Roof entries SHD – swan neck roof entry SHD – swan neck roof entry Features and technical data Swan neck roof entry – SHD: • flexible, modular system suitable for all flat roof structures • individual components, thus low transport weight • height (min. 300 mm) and orientation can be adjusted (can be swivelled through 360°) even after installation • available in 4 sizes, 100, 150, 200 and 300 mm diameters • all steel parts are hot-dip galvanized • sealing of cables in swan neck after installing the cables possible with split sealing insert SKD (pressure plates made of stainless steel V2A (AISI 304L), rubber quality EPDM) pipe elbow 30°30 ° Rohrbogen pipe elbow Rohrbogen 9090° ° B 200 intermediate pipe Zwischenstück (can be removed) (demontierbar) drip cap Abtropfhaube header Grundrohr membrane Dichtbahn A (mm) B (mm) C ( mm) D (ID mm) E ( mm) SHD 100 600 – 950 1050 – 1400 250 100 300 SHD 150 600 – 950 1175 – 1525 300 150 350 SHD 200 600 – 950 1300 – 1650 350 200 400 SHD 300 600 – 950 1550 – 1900 450 300 500 A = min./max. telescope range B = overall height C = hole pattern 4 x 12 mm diameter D = max. core drilling diameter E = base plate edge dimension 500 A height-adjustable höhenverstellbares extension pipe Verlängerungsrohr Typ Item Article code Article number Swan neck roof entry, ID=100 mm, for dowelling above core drilled holes, rotatable by 360°, height-adjustable SHD 100 1001094300 Swan neck roof entry, ID=150 mm, for dowelling above core drilled holes, rotatable by 360°, height-adjustable SHD 150 1001094500 Swan neck roof entry, ID=200 mm, for dowelling above core drilled holes, rotatable by 360°, height-adjustable SHD 200 1001094000 Swan neck roof entry, ID=300 mm, for dowelling above core drilled holes, rotatable by 360°, height-adjustable SHD 300 1001095000 Item Article code Article number Seal insert, for swan neck SHD 100 (pressure plates made of stainless steel V2A (AISI 304L), rubber quality EPDM) SKD 100-2G-Z/d 1001094310 Seal insert, for swan neck SHD 150 (pressure plates made of stainless steel V2A (AISI 304L), rubber quality EPDM) SKD 150-2G-Z/d 1001094510 Seal insert, for swan neck SHD 200 (pressure plates made of stainless steel V2A (AISI 304L), rubber quality EPDM) SKD 200-2G-Z/d 1001094010 Seal insert, for swan neck SHD 300 (pressure plates made of stainless steel V2A (AISI 304L), rubber quality EPDM) SKD 300-2G-Z/d 1001095010 Picture SKD – cable sealing for swan neck Picture D C E membrane Dichtbahn base plate Grundplatte Extra insulation Isolierung Z = number of cables d = measured cable diameter Installed SHD 200 before laying of cables 50 Swan neck entry SHD 200 complete with seal insert SKD cablepipebuildingentry+ 51 Foundation pipes HFR – Foundation pipes for lamp posts Foundation pipes HFR – Foundation pipes for lamp posts HFR – Foundation pipes for lamp posts Item Features and technical data Article code Article number Foundation pipe, pipe length = 600 mm HFR300/600/85/400 0915000100 Foundation pipe, pipe length = 800 mm HFR300/800/85/600 0915000200 Foundation pipe, pipe length = 1000 mm HFR300/1000/85/600 0915000250 Foundation pipe, pipe length = 1200 mm HFR300/1200/85/600 0915000300 Picture Foundation pipe: ID = 290 mm, OD = approximately 335 mm Foundation pipes for lamp posts – HFR: • foundation pipe, for masts, fence posts, flag posts etc. • low weight, thus easy handling • ribbed plastic design • resistant to corrosion and chemicals • high stability and long service life • available in nominal diameters 300, 400 and 500 mm • individual lengths available • cover available as protection against dirt (not included in scope of delivery) • posts can be installed at any point in time during construction • damaged posts can easily be replaced Foundation pipe: ID = 390 mm, OD = approximately 450 mm Article code, e.g.: HFR 300 / 1200 / 85 / 750 hole position from outer edge in mm (Y) hole diameter in mm 85 length in mm (X) Technical details nominal diameter Foundation pipe, pipe length = 800 mm HFR400/800/85/600 0916000200 Foundation pipe, pipe length = 1000 mm HFR400/1000/85/600 0916000250 Foundation pipe, pipe length = 1200 mm HFR400/1200/85/600 0916000300 Foundation pipe, pipe length = 1400 mm HFR400/1400/85/600 0916000400 Foundation pipe: ID = 490 mm, OD = approximately 560 mm Foundation pipe, pipe length = 800 mm HFR500/800/85/600 0918000200 Foundation pipe, pipe length = 1000 mm HFR500/1000/85/600 0918000250 Foundation pipe, pipe length = 1200 mm HFR500/1200/85/600 0918000300 Foundation pipe, pipe length = 1400 mm HFR500/1400/85/600 0918000400 Foundation pipe, pipe length = 1600 mm HFR500/1600/85/600 0918000500 lean concrete soil filling material e.g. sand Extra lamp post Accessories Item Article code Article number PE cover for HFR 300 for protecting against dirt HFR 300-D 0918000900 PE cover for HFR 400 for protecting against dirt HFR 400-D 0918000910 PE cover for HFR 500 for protecting against dirt HFR 500-D 0918000920 duct supply line lean concrete Sectional view 52 cablepipebuildingentry+ 53 General Terms and Conditions of Sale and Delivery General Terms and Conditions of Sale and Delivery I. Scope of Application 1. The following Terms and Conditions of Sale and Delivery shall apply to all contracts concluded between the buyer and us concerning the sale and delivery of goods. They shall also apply to all future business relations, even if not expressly agreed upon once again. Deviating terms and conditions of the buyer which are not expressly recognised by us shall not be binding upon us, even if we do not expressly object to them. Our Terms and Conditions of Sale and Delivery shall apply even if we carry out the buyer‘s order unconditionally in the knowledge of contrary or deviating terms and conditions of the buyer. 2. Verbal collateral agreements shall only be binding for us if we have confirmed them in writing. A waiver of the written form requirement must be in writing. 3. The Terms and Conditions of Sale and Delivery shall only apply to entrepreneurs in the sense of Section 14 of the German Civil Code (BGB), legal persons under public law and special funds under public law; it shall not apply to consumers (Section 13 of the BGB). 2. If there is a defect in the goods for which we are responsible, we shall undertake to effect subsequent performance – excluding the rights of the buyer to withdraw from the contract or to reduce the purchase price (reduction) – unless we are entitled to refuse to effect subsequent performance due to the statutory regulations. The buyer must grant us a reasonable period of time for the subsequent performance. The subsequent performance may be effected either by removal of the defect (subsequent improvement) or by delivery of new goods. In the case of the removal of a defect, we shall bear the necessary costs provided that these do not increase because the contractual item is at a location other than the place of performance. At our reasonable discretion, we shall be entitled to determine the type of subsequent performance. Any subsequent performance by us shall take place without recognition of a legal obligation, unless the defect has been recognised by us. If the subsequent performance fails, the buyer may, at his/her discretion, demand a reduction in the purchase price (reduction) or declare his/her withdrawal from the contract. The subsequent improvement shall be deemed to have failed after the second unsuccessful attempt, unless further attempts to achieve an improvement are appropriate and reasonable for the buyer in view of the nature of the contractual item. Compensation claims according to statutory provisions due to a defect may only be asserted by the buyer if the supplementary performance fails. The buyer shall not be entitled to demand compensation claims or a reduction in the purchase price in the case of insignificant defects. 3. The claims of the buyer due to defects in the purchased item shall lapse 5 years after delivery of the goods to the buyer if they were used for construction work in accordance with their normal method of utilisation and this has caused their defectiveness. This shall also apply to claims of the buyer for compensation or compensation instead of service, and due to all other damage to the buyer‘s rights arising from the defect; it shall not, however, apply to damage to the life, limb or health of the buyer, or to cases in which we are responsible for the defect as a result of wilful intent or gross negligence, including on the part of our vicarious agents. II. Conclusion of Contract 1. We may accept any order from the buyer which can be qualified as an offer to conclude a purchase contract by sending an order confirmation within two weeks or by shipping the ordered products within the same period. 2. For the purpose of performing a credit check on the buyer, and provided that we have demonstrated a legitimate interest, we shall be entitled to retrieve any address and financial data for the buyer that has been stored, including such data that can be determined on the basis of mathematical and statistical methods, via the companies Bürgel Wirtschaftsinformationen GmbH & Co. KG, Postfach 500166, 22701 Hamburg, Germany; Creditreform, Stuttgarter Str. 35, 73430 Aalen, Germany; and Bisnode D&B Deutschland GmbH, Robert-Bosch-Str. 11, 64293 Darmstadt, Germany. To enable decisions concerning the establishment, execution or termination of the contractual relationship, we shall collect or use probability figures calculated using information including address data. 3. Our offers shall be non-binding and subject to change, unless we have expressly designated them as binding. 4. We hereby reserve the title, copyright and all other property rights to all pictures, calculations, drawings and other documents. The buyer may only pass on such pictures, etc. to third parties with our written approval, irrespective of whether we have identified such pictures, etc. as confidential. III. Terms and Conditions of Payment - Prices 1. Our prices are ex works and do not include packaging, unless stipulated otherwise in the order confirmation. Our prices do not include the statutory value added tax. We shall disclose the amount of value added tax applicable on the invoice date separately in our invoice. 2. Cash discounts are not permitted unless otherwise agreed in writing between us and the buyer. The purchase price shall be payable without deduction immediately upon receipt of the invoice by the buyer if no other payment term is specified in the order confirmation. A payment shall only be deemed to have been made when we are able to dispose of the amount. In the case of cheque payments, payment shall only be deemed to have been made when the cheque is cleared. 3. If the buyer is in default of payment, the legal regulations shall apply. 4. The buyer shall only be entitled to set-off, even if complaints or counterclaims are being made, if the counterclaims have been determined in a final and legally binding manner, have been acknowledged by us or are undisputed. The buyer shall only be authorised to exercise a right of retention if his/her counterclaim is based on the same contractual relationship. We shall be authorised to exercise a right of retention on all receivables arising from the business relationship with the buyer. IV. Delivery Time, Performance Time and Delivery Delays 1. Delivery dates or periods which have not expressly been agreed as binding are exclusively non-binding information. The delivery time quoted by us shall only commence when the technical issues have been clarified. Similarly, the buyer is obliged to fulfil all of the obligations to which he is subject, both properly and in a timely manner. We reserve the right to the defence of lack of performance of the contract. 2. In the event of delay, we shall be liable in accordance with the statutory provisions if the buyer is able to justify that he has no further interest in fulfilment of the contract as a result of a delay in delivery for which we are responsible, if we have guaranteed delivery periods or if the delivery delay is based on an intentional or grossly negligent breach of contract for which we, our representatives or our vicarious agents are responsible. 3. In the event that a delivery delay for which we are responsible – and where a fault on the part of our representatives or vicarious agents is to be ascribed to us – is due to a grossly negligent or intentional breach of contract on our part or a slight breach of a fundamental contractual obligation on our part, we shall be liable in accordance with the statutory provisions, with the proviso that in such cases our compensation liability is limited to the foreseeable, typically occurring damage or loss. 4. The buyer’s other statutory claims and rights to which he/she is entitled in addition to the compensation claim due to a delivery delay for which we are responsible shall remain unaffected by this. If a culpable breach of a non-fundamental contractual obligation caused by us leads to a delivery delay for the buyer, the compensation claim for this shall be limited to 25% of the delivery value. V. Transfer of Risk – Dispatch/Packaging 1. Loading and dispatch shall take place without insurance at the buyer’s risk, „ex stock“ or „ex works“, unless otherwise specified in our order confirmation. We shall endeavour to take into account the dispatch type and the dispatch route wishes and interests of the buyer; any additional costs caused by this – even in the case of agreed freight-free delivery – shall be borne by the buyer. 2. We shall not take back transport packaging or any other packaging in accordance with the German Packaging Ordinance; pallets are excluded. The buyer is obligated to take care of the disposal of the packaging at his/her own cost. 3. If the dispatch is delayed at the request of or due to a fault on the part of the buyer, we shall then store the goods at the buyer’s cost and risk. In this case, the announcement of readiness for dispatch shall be treated as equivalent to the dispatch. 4. Upon the request and at the cost of the buyer, we shall insure the delivery through a transport insurance policy. 5. We shall be entitled to make partial deliveries and render partial services at any time, provided that this is reasonable for the buyer. VI. Acceptance 1. The buyer shall undertake to carry out all actions that require acceptance of our delivery. In the event of a culpable breach of this obligation by the buyer, he/she shall be liable to us for any additional expenses; in such cases, we shall also reserve the right to assert further compensation claims. 2. If the buyer‘s acceptance of the delivery is delayed by more than 14 days, we shall grant, in writing, a grace period of 14 days for the acceptance; at the same time, we shall issue a notification that acceptance will be rejected if this defined period expires without the action having been carried out. Should the buyer allow the defined grace period to elapse without the action having been carried out, we shall be entitled to withdraw from the purchase contract by means of a written declaration, or to demand compensation for non-performance. Should the buyer continue to refuse acceptance, or should he/she become aware that payment of the purchase price will not be possible even if a grace period is granted, there shall be no requirement to grant a grace period. 3. In such cases, we shall be entitled to claim the loss of profits with an amount of 10 % of the agreed purchase price, unless the buyer proves that we incurred a lower dammage. Irrespective of this, we shall be entitled to prove a higher dammage and claim for higher dammages. VII. Warranty 1. The buyer‘s claims due to defects only exist if the buyer has duly complied with his/her inspection and complaint obligations in accordance with Section 377 of the German Commercial Code (HGB). If the buyer makes changes to our product, fails to follow our operation, installation and maintenance specifications or does not follow them sufficiently, or uses parts or consumables that have not been approved by us, our warranty obligation shall no longer apply, unless the buyer can prove that the defect concerned is not the result of one of these circumstances. Otherwise, our installation instructions and guarantee conditions shall apply. 54 VIII. Liability 1. In the case of wilful intent or gross negligence – including on the part of our representatives or vicarious agents – and in all cases of injury to life, limb or health, we shall be liable in accordance with statutory provisions. In cases of gross negligence, our liability shall be restricted to foreseeable damage that is typical for the contract, unless another of the exceptions listed in sentence 1 or sentence 3 of this paragraph 1 is present at the same time. Otherwise, we shall only be liable in accordance with the German Product Liability Act or as a result of a culpable breach of fundamental contractual obligations (cardinal obligations) or if we have fraudulently concealed the defect or assumed a guarantee for the properties of the purchased item. However, compensation claims for the breach of fundamental contractual obligations shall be restricted to foreseeable damage that is typical for the contract, unless another of the exceptions listed in sentence 1 or sentence 3 of this paragraph 1 is present at the same time. 2. The regulations of the previous paragraph 1 shall apply to all compensation claims (and particularly to compensation in addition to service and compensation instead of service), regardless of the legal basis, particularly when arising as a result of defects, a breach of obligations from the obligatory relationship, or tortious acts. They shall also apply to claims for compensation of wasted expenditure. However, liability for delivery delays shall be determined in accordance with Clause IV. of these Terms and Conditions of Sale and Delivery. 3. Any change to the burden of proof that is to the disadvantage of the buyer is not connected to the previous regulations. IX. Retention of Title 1. The delivery item shall remain our property up to the point at which all our claims against the buyer arising from the business relationship have been satisfied. 2. The buyer shall be permitted to process or remodel the delivery item („processing“). Processing shall be carried out for us. If, however, the value of the delivery item belonging to us is lower than the value of the goods not belonging to us and/or the processing, we shall acquire co-ownership of the new goods in the proportion that the value (gross invoice value) of the processed delivery item has to the value of the other processed goods and/or the processing at the time when the processing took place. If we do not acquire any ownership of the new goods in accordance with the preceding sentence, we and the buyer shall agree that the buyer shall grant us co-ownership of the new goods in the proportion that the value (gross invoice value) of the delivery item belonging to the buyer has to the other processed goods, at the point when processing took place. The previous sentence shall apply accordingly in the event that the delivery item is inseparably amalgamated or combined with goods not belonging to us. To the extent that we acquire ownership or co-ownership, we shall keep the goods safe for the buyer with the due care and diligence of a prudent businessman. 3. In the event that the delivery item or the new goods are sold, the buyer hereby assigns to us by way of security his/her claims arising from the resale against his/her customer, plus all ancillary rights, without the need for any additional special declarations. The assignment shall apply inclusive of any balance receivables. However, the assignment shall only apply to the amount that corresponds to the price of the delivery item invoiced by us. The share of the receivable assigned to us must be satisfied as a matter of priority. 4. If the buyer combines the delivery item or the new goods with property, he/she shall – without the need for any additional special declarations – also assign his/her receivables to which he/she is entitled as remuneration for the combination, at the amount that corresponds to the price of the delivery item invoiced by us. 5. Until further notice, the buyer shall be entitled to collect receivables assigned to us. The buyer shall immediately forward payments made towards the receivables assigned to us, up to the amount of the secured receivable. If there is a legitimate interest, and particularly in the case of default of payments, suspension of payments, opening of insolvency proceedings, protest of a bill, or substantiated evidence of overindebtedness or impending insolvency of the buyer, we shall be authorised to withdraw the buyer‘s right of collection. Additionally, following prior warning and with a reasonable deadline adhered to, we may disclose the security assignment, make use of the assigned receivables, and demand disclosure of the security assignment by the buyer to his/her customers. 6. If a justified interest is substantiated, the buyer must provide us with the information necessary to assert his/her rights in respect of his/her customers, and surrender the necessary documents. 7. For the duration that the retention of title is in place, the buyer shall be prohibited from pledging or assignment as security. In the event of seizure, confiscation or other official orders or acts of intervention by third parties, the buyer must notify us immediately. The resale of the delivery item or the new goods is only permitted for resellers in the ordinary course of business, and only under the condition that the proceeds from the delivery item are paid to the buyer. The buyer must also agree with the customer that the customer shall only acquire ownership once this payment is made. 8. If the realisable value of all security rights to which we are entitled exceeds the amount of the secured claims by more than 10%, we shall release a corresponding part of the security rights at the buyer‘s request. It shall be assumed that the conditions of the previous sentence have been met if the estimated value of the securities to which we are entitled reaches or exceeds 150% of the value of the secured claims. We shall be entitled to choose between the different security rights for release. 9. If the buyer breaches obligations – particularly in respect of default of payment – we shall be authorised, without setting a deadline, to demand surrender of the delivery item or the new goods and/or, with a deadline set if necessary, to withdraw from the contract. The buyer shall undertake to surrender possession. A demand for the surrender of the delivery item/new goods shall not constitute a declaration of withdrawal on our part, unless expressly stated. X. Legal Venue, Choice of Law, Data Protection 1. Our registered office shall be the place of performance and jurisdiction for deliveries and payments (including actions due to cheques and bills of exchange) and all disputes arising between us and the buyer based on the purchase contracts concluded between us and the buyer. We shall also be entitled, however, to sue the buyer at his/her domicile and/or registered office. 2. The relations between the contracting parties shall be determined exclusively in accordance with the law of the Federal Republic of Germany. The application of international conventions concerning the sale of movable goods and the UN Convention on Contracts for the International Sale of Goods of 11.04.1980 (CISG) are excluded. 3. The execution of contracts concluded between us and the buyer shall take place in compliance with legal provisions such as the German Federal Data Protection Act (BDSG) and the German Telemedia Act (TMG). We shall undertake to work towards compliance with these regulations, including in respect of service providers commissioned by us and vicarious agents employed by us. In this context, we refer to the latest version of the data protection statement published on our homepage at www. hauff-technik.de/datenschutz.html. 4. The German version of the contents of our General Terms and Conditions of Sale and Delivery shall apply exclusively, even if there are versions in other languages. Version: August 2014 cablepipebuildingentry+ 55 Return Policy Your notes Your notes Requirements for return of goods: Goods have to be in good order and condition Return is accepted maximum within 6 months after date of invoice Return deliveries must always be free house (ddp Incoterms 2010) to Hauff-Technik GmbH & Co. KG. The return delivery number must be shown clearly Return of goods must be announced in written to Hauff Technik and confirmed by us in written Returns can only be dealed with when return file number is indicated Individual/tailor made products are non-returnable Expenses allowance Credit is issued with deduction for handling charges for examination, assembling and re-storage and possible reduced value Below listed deductions are only valid for the standard products of the particular article group: Single and multiple house entries (without pipes and fittings) 30 % Membrane injection systems (without epoxy resin) 30 % Standard press seals for pipes, type HSD in EPDM 30 % Sealing Set ADS for corrgugated pipes 30 % Standard press seals for cables type HRD-SG 30 % HSI 90/HSI150 system covers 30 % Roof Sealing swan neck 30 % Earthing points 30 % No return possible for: Tailor made products / length Standard press seals type HSD in KTW / NBR / Silicone rubber / V4A (AISI 316L) Individual press seals for pipes type HRD Package and angular packages of the HSI Wall sleeves type ZVR / FZR and foundation pipe type HFR Standard wall sleeves / stainless steel wall sleeves Hateflex pipes / corrguated pipes Article with an expiration date Gas and water fittings Subject to changes 56 cablepipebuildingentry+ 57 Hauff-Technik GmbH & Co. KG Robert-Bosch-Straße 9 89568 Hermaringen, GERMANY Tel. +49 7322 1333-0 Fax +49 7322 1333-999 office@hauff-technik.de www.hauff-technik.de katalog_kabel_en_150824 The information in this publication represents our current state of technical knowledge and experience. However, given the multitude of possible influences affecting the processing and use of our products, this information does not exempt processors and users from running their own tests and trials. We will replace any parts that cannot be used due to defective materials. We do not replace parts for defects caused due to transport, storage or faulty installation and the consequences thereof. All information without guarantee. Submitted by: