Always. Reliable. Tight. Catalogue 2014 Cable Entries Prices valid as of 01.04.2014 cablespipesbuildingentries+ Solutionmap Cables, pipes, building entries: Always. Reliable. Tight. Catalogue Content Cable Entries Cable entries • Cable entry systems HSI 150 HSI 150 6 – 15 KES-M 150 16 – 18 Accessories 19–19 • Cable entry systems HSI 90 HSI 90 20 – 25 KES-M 90 26 – 28 Accessories 29–29 Press seals • Fire protection for cables F-CABLE HVS/HSS 30 – 31 Press seals • Press seals for cables P-CABLE Basic SG 32 – 33 (universal seal for cables) 34 – 37 • Wall sleeves P-LINER Basic / Professional 38 – 41 eXtra Electricity, telecommunication, water, waste water, gas or district heating - whenever a perfectly safe sealing of building entries is required, Hauff-Technik offers the best possible solution. Innovative cable and pipe entries, building entries and trenchless house connections of professional quality. All from one source. Out of the box or customized products. For highest efficiency, user-friendliness and longevity in all buildings. From single-family homes to complex major projects. Always Hauff. Always reliable. Always tight. P-CABLE Professional (closed / split sealing insert) eXtra 2 • Foundation pipe for street illumination 50–51 • Roof entry 52–53 General Terms of Business 56–57 cablespipesbuildingentries+ General Terms of Business • Earthing fixed points HEA HEA 42–49 3 Application tachometer To determine your specific requirements fü r Ka b el rd Roh d Overview wall structure / Sealing of building entries Basis to determine the appropriate cable and pipe entry systems urchführungen ickerwasser, Grundwas än ndes S U-Beton Beanspru ser, Schic h chung taue ,W gi sklas tenwa aufs ckwasser : z se 1 sse ru at g s D r, n Ei un vo n d ar, 0,3 b Einbautiefe 0 – 3m >0 ,3 ba r, E m nf – >3 or de ru ng 0– A – 0– e0 ief ut ba in 0 – 0,1 b ar, E inb au tie fe 0 1 m Sealing according to DIN 18195 – Part 4 Soil humidity and non-standing seepage water Sealing according to DIN 18195 - Part 6 Standing seepage water and pressing water No. 1 No. 5 brick-built basement wall brick-built basement wall e Brick-built basement wall chungen ng anspru onen hu re Be ati u c , besonridgee Einbausitu pr gen wie n s elastusnch), sch kb rmi ea B Schoch, the : c tz is sa m in (che E r nge 2 e Au Einsatz: nic h sw wasser, Sp t stauend ritzw ah e asse s Sick r, W lk erw U-B a ri eto sse te n B r, B ea od ri ns en pr fe e uc u n hu ch ng te, sk R e la ss Wall type basement/ Wall structure – a bh sealing on outside of building sealing on outside of building No. 2 concreted basement No. 6 concreted basement Concreted basement sealing on outside of building No. 3 Products according to load cases DIN 18195/stress class waterproof concrete, example used is press seal for cables double wall / element wall sealing on outside of building No. 7 double wall / element wall Double wall / Element wall Product group Sealing width Catalogue page HRD 1 30 mm 35 HRD SG 40 mm 33 HRD 2 60 mm 37 sealing on outside of building No. 4 thermal insulation Double wall / Element wall with thermal insulation Please note: Wall inserts and flanges must be used in compliance with DIN 18195 and/or DIN 1045! sealing on outside of building No. 8 thermal insulation double wall / element wall double wall / element wall sealing on outside of building sealing on outside of building Waterproof concrete according to DIN 1045 Concreted basement with waterproof concrete No. 9 concreted basement Double wall / element wall with waterproof concrete No. 10 double wall / element wall Double wall / element wall with waterproof concrete and thermal insulation No. 11 thermal insulation double wall / element wall If you do not find your wall structure among above examples, kindly let us have a sketch. 4 + 5 cablespipesbuildingentries 5 Cable entry systems HSI 150 V-Body HSI 150 – Wall inserts, aluminium flange Cable entry systems HSI 150 V-Body HSI 150 – Wall inserts, aluminium flange V-Body HSI 150 – Wall inserts • waterproof concrete stress class 1 Item Features and technical data Wall insert – HSI 150-K/X: Wall insert – HSI 150-K2/X: Wall insert – HSI 150-GSM: • single-sided connection to system sealing possible • minimum wall thickness 70 mm • blind cover and blind plate (to be knocked out) guarantee double safety at wall thicknesses 70 – 150 mm (in 10 mm steps) • available for individual wall thicknesses ≥ 150 mm • plug-in frame system for block assembly • pressure-tight up to 2.5 bar after concreting • connections to system sealing possible on both sides • minimum wall thickness 100 mm • available for individual wall thicknesses ≥ 100 mm • plug-in frame system for block assembly, available ex stock • closed on both sides with blind system cover • special designs for double wall/ element walls available • pressure-tight up to 2.5 bar after concreting • single-sided connection to system sealing, with integrated plug-in socket to connect smooth cable ducts • no additional duct connection material necessary • minimum wall thickness for pipe connection 110 and 125 mm diameter: 120 mm • minimum wall thickness for pipe connection 160 mm diameter: 230 mm • maximum wall thickness: 500 mm • pressure-tight up to 2.5 bar after concreting (pressure-tight up to 0.5 bar depending on the cable duct used) Single wall insert from wall thickness 70 mm Double wall insert from wall thickness 100 mm Double wall insert for element walls 430 mm frame size 220 x 220 mm 210 mm 210 mm Single wall insert with integrated plug-in socket Ø 110 mm from wall thickness 120 mm Single wall insert with integrated plug-in socket Ø 125 mm from wall thickness 120 mm Installation movie 1.060 mm Article code Picture Cable entries Application: HSI 150-K/X X = wall thickness in mm HSI 150-K2/X X = wall thickness in mm HSI 150-K2-EW/X X = wall thickness in mm HSI 150-GSM 110/X** X = wall thickness in mm HSI 150-GSM 125/X** X = wall thickness in mm Example as a 2x5 block for 200 mm wall thickness. Article code: HSI 150-2x5-K2/200 Single wall insert with integrated plug-in socket Ø 160 mm from wall thickness 230 mm combination in packages only possible with spacer Spacer one set consists of 2 pieces to increase center distances by 40 mm, possibility to combine HSI 150 and HSI 90 in bundles HSI 150-GSM 160/X X = wall thickness in mm HSI-AH 40 * for wall thicknesses > 500 mm price on request ** restrictions regarding number and size of cables may occur Slanted wall inserts (30°, 45° und 60°) and customized solutions according to DIN 18195 part 6 available on request. Double wall insert HSI 150 fixed as package into the formwork V-Body HSI 150 – Aluminium flange Application: non-standing seepage water, waterproof concrete stress class 1 Aluminium flange HSI 150-DF 235 mm 6 67 mm core drilling max. 150 mm diameter • connection to system sealing possible • aluminium flange with KTL (cataphoretic) - coating (optimised protection against corrosion) • for retrofit fixing • core drilling max. 150 mm diameter • installation on container walls possible • including chloroprene (CR) surface seal, 10 mm thick and fastenings made from stainless steel V4A (AISI 316L) for concrete walls 235 mm Aluminium flange – HSI 150-DF: Sectional drawing Spacing dimensions 85 mm Features and technical data Min. 235 mm • Item Article code Aluminium flange incl. fastenings made of stainless steel V4A (AISI 316L) for concrete walls HSI 150-DF Cartridge of 300 ml colour: grey elastic sealant to optimize wall surface when used with sealing flange Picture 1-component sealant Sikaflex-11 FC 10 mm cablespipesbuildingentries+ 7 Cable entry systems HSI 150 V-Insert HSI 150 – System cover heat shrink method Cable entry systems HSI 150 V-Insert HSI 150 – System cover heat shrink method, accessories V-Insert HSI 150 – System cover heat shrink method Item Area of application cable/pipe diameter Article code System cover, closed sealing cover blind cover HSI 150-D System cover with 1 socket incl. 1 piece heat-shrink sleeve 1 piece centering tape 25 – 78 mm HSI 150-D1/80 System cover with 3 sockets incl. 3 pieces heat-shrink sleeves 3 pieces centering tape 22 – 56 mm HSI 150-D3/58 System cover with 7 sockets incl. 7 pieces heat-shrink sleeves 12 – 31 mm HSI 150-D7/33 Picture System cover heat shrink method – HSI 150-D1/80, -D3/58 and -D7/33: • wide application area • easy installation with bayonet catch • including centering tape at HSI 150-D1/80 and HSI 150-D3/58 • unused opening can be closed off with blind plugs VS32/34 respecitvely VS 58/60 • also available with cold shrink sleeves • UV- and ozone resistant • resistant to transformer oil Cable entries Features and technical data Types with cold shrink sleeves available on request. V-CABLE HSI 150 – Accessories Transformer station entry: low-voltage cable sealed with HSI 150-D1/80 Centering tape installed in system cover socket of HSI 150-D3/58 stainless steel hose clamp wrench size13 Application Sealing plug for system cover HSI 150-D7/33 Sealing plug for system cover HSI 150-D3/58 Cross-section of a concrete wall flexible, pressurestable KES-hose Item Article code Picture VS 32/34 to seal unused sockets VS 58/60 concrete wall 3-ribbed seal extension pipe Centering tape – set of 3 pieces elastomer strips 30 x 430 mm wall insert clamping nut system cover for centering and fixing the cables into the system cover sockets for optimal shrinking HSI-ZB cable V-CABLE HSI 150 – Replacement -/ Repair shrink sleeves Item heat shrink-fit sleeve rubber sleeve for system cover Article code HSI 150-D1/80 TM2.200.92.25 HSI 150-D3/58 TM2.200.75.22 HSI 150-D7/33 TM2.150.43.12 HSI 150-D1/80 TMR3.250.107.29 HSI 150-D3/58 TMR3.250.84.20 HSI 150-D7/33 TMR3.250.53.13 sliding and O-ring Replacement shrink sleeves for HSI 150 x = wall or masonry thickness Repair sleeves for HSI 150 Installation movie 8 cablespipesbuildingentries+ 9 Cable entry systems HSI 150 V-Insert HSI 150 – System cover for new and retrofit installation, accessories Cable entry systems HSI 150 V-Insert HSI 150 – System cover for new and retrofit installation, accessories V-Insert HSI 150 – System cover for new and retrofit installation System cover for new and retrofit installation – HSI 150-DG: • split seal for new and retrofit installation • individual adjustment to the diameter of the laid cables on site • inscribed segment rings • blind plugs for HSI 150-DG-3/24-54 and HSI 150-DG-6/10-36 included in the delivery • transformer oil leak-tightness, tested over 90 days – KIWA Institute • plastic pressure plates made of polyamide 6.6 with 30 % glass-fibre reinforcement • V2A (AISI 304L) stainless steel screws and nuts • pressure-tight up to 2.5 bar Area of application cable/pipe OD Article code Split system cover with 1 opening incl. split adapter ring 36 – 70 mm HSI 150-DG-1/36-70 Split system cover with 1 opening incl. split adapter ring 70 – 112 mm HSI 150-DG-1/70-112 Split system cover with 3 openings incl. split adapter ring and 3 pieces blind plugs 24 – 54 mm HSI 150-DG-3/24-54 Split system cover with 6 openings incl. split adapter ring and 6 pieces blind plugs 10 – 36 mm HSI 150-DG-6/10-36 Picture Cable entries Features and technical data Item Scope of delivery of HSI 150-DG includes: lubricating stick GM, knife, cleaning cloth V-CABLE HSI 150 - DG – Accessories Low-voltage cables sealed with HSI 150-DG-6/10-36 Pressure plate cover HSI 150-PA-3/24-54 Various installation stages of HSI 150-DG-3/24-54 Item Application Article code Press plate cover for HSI 150-DG-3/24-54 for protecting the threads against dirt HSI 150-PA-3/24-54 Press plate cover for HSI 150-DG-6/10-36 for protecting the threads against dirt HSI 150-PA-6/10-36 Torque wrench (4-20 Nm) with extensions and Allen key tool for installation of system cover HSI 150-DG assembly set HSI 150-DG Picture HSI 150-DG: inscription of diameters on segments Installation movie 10 cablespipesbuildingentries+ 11 Cable entry systems HSI 150 V-Insert HSI 150 – SEGMENTO Cable entry systems HSI 150 V-Insert HSI 150-SEGMENTO, combination kit SEGMENTO, accessories V-Insert HSI 150-SEGMENTO SEGMENTO – HSI 150-SEGMENTO: • • • • • • • • • • particularly flexible and gentle sealing for cables with 5 to 31 mm diameter individual clamping of segments no time-consuming modular design easy and quick installation of segments segments can be combined as necessary integrated torque control system simple reinstallation possible all segment openings closed with blind plugs gas- and watertight up to 0.5 bar when installed on outside of building Article code System lid as segment receptacle HSI 150-S3 The violet segment application area for 2 cables, diameter 20-31 mm incl. 2 blind plugs SEG 2/31 The yellow segment application area for 3 cables, diameter 20-26 mm incl. 3 blind plugs SEG 3/26 The blue segment application area for 6 cables, diameter 15-21 mm incl. 6 blind plugs SEG 6/21 The orange segment application area for 8 cables, diameter 5-15 mm incl. 8 blind plugs SEG 8/15 Picture Cable entries Features and technical data Item Combination kit SEGMENTO HSI 150 - wall insert with SEGMENTO sealing of control lines in a substation HSI 150 - SEGMENTO – with integrated torque control system and bling plugs Item Article code KKS combination kit for pressure-tight outside sealing of core drillings with a diameter of 150 mm consisting of: 1x aluminium flange HSI 150-DF with fastenings, 1x system cover HSI 150-S3, 3x selected segments SEG x/xx, 1x GMS lubricant, 1x installation instructions KKS Picture SEGMENTO accessories Sealing of cables for street lighting with SEGMENTO Item Article code Lubricant SEGMENTO 10 g GMS Cable diameter gauge SEGMENTO to determin the suitable segments according to the cable diamter BSS Torque screwdriver (1,2 Nm) SEGMENTO with acoustic signal DMS Picture Installation instructions 12 cablespipesbuildingentries+ 13 Cable entry systems HSI 150 V-Insert HSI 150 – system cover for pipe connection Cable entry systems HSI 150 V-Guard HSI 150 – Cable duct connections V-Guard HSI 150 – Plug-in socket system for smooth pipes Plug-in socket system – HSI 150 – D (pipe OD) GSM: Sleeve method – HSI 150 – M (pipe OD): Cold shrink method – HSI 150 – D (pipe OD) KS: • for smooth pipes / ducts • easy and quick installation, no additional connecting components necessary • economic solution • compact design • pressure-tight up to 0.5 bar, depending on the pipe / duct used • can be used with smooth and corrugated pipes • patented clip ring technology for sealing of corrugated pipes (indicate pipe type and pipe manufacturer, please) • mechanically stable, elastic connection using special sleeves and tightening straps made from stainless steel V4A (AISI 316L) • pressure-tight up to 0.5 bar, depending on the pipe / duct used • for corrugated pipes • shrink method, no tools necessary • stress-free sealing for pressure-sensitive pipes • pressure-tight up to 0.5 bar, depending on the pipe / duct used Pipe OD Article code System cover for pipe connection 110 mm HSI 150-D 110-GSM System cover for pipe connection 125 mm HSI 150-D 125-GSM System cover for pipe connection 160 mm HSI 150-D 160-GSM Picture Cable entries Features and technical data Item V-Guard HSI 150 – Rubber sleeves for smooth and corrugated pipes Item Pipe OD System cover for smooth pipes System cover for corrugated pipes incl. clip rings System cover for smooth pipes System cover for corrugated pipes incl. clip rings System cover for smooth pipes System cover for smooth pipes Connection of corrugated pipes with cold shrink method HSI 150-M 168 System cover for corrugated pipes incl. clip rings Article code Picture HSI 150-M 110 110 mm HSI 150-M 110-WR* HSI 150-M 125 125 mm HSI 150-M 125-WR* 140 mm HSI 150-M 140 HSI 150-M 168 160 mm HSI 150-M 168-WR* *Kindly indicate pipe manufacturer and pipe type in your order. For each pipe connection 2 profile sealing rings are necessary (available from the pipe manufacturer, to be provided on-site). V-Guard HSI 150 – Cold shrink sleeves for corrugated pipes Connection of corrugated pipes with cold shrink sleeves HSI 150-D 110-KS Connection of rigid cable protection pipe DN 125 with HSI 150-D 125-GSM Item Pipe OD Article code System cover for corrugated pipes 110 mm HSI 150-D 110-KS System cover for corrugated pipes 125 mm HSI 150-D 125-KS Picture V-CABLE HSI 150 – Replacement cold shrink sleeves Item Replacement shrink-fit sleeves for HSI 150 Installation movie 14 cablespipesbuildingentries+ For system cover Article code HSI 150-D 110-KS KS 223.119.56 HSI 150-D 125-KS KS 240.154.76 15 Cable entry systems HSI 150 V-Guard KES-M 150 – Cable entry systems Cable entry systems HSI 150 V-Guard KES-M 150 – Cable entry systems V-Guard KES-M 150 – Cable entry system • waterproof concrete stress class 1 Features and technical data Cable entry system – KES-M 150: • pressure-tight ducting system up to 2.5 bar (outer pressure) for connecting HSI 150-wall inserts • high mechanical stability • elastic connection with special system sleeves and straps made of stainless steel V4A (AISI 316L) • smooth inner surface for gentle cable feeding • sealing of cables with heat shrink or cold shrink sleeves or rubber press seals • adaption with common cable ducts possible • also available as role commodity (up to a length of 25 m), extension possible with connection sleeve KES-M 150 HTV Pressure-tight connection of Hateflex 14150 to HSI 150-wall inserts Entry of KES-systems through slab. Auxiliary construction provided on site. Cross-section of a concrete wall flexible, pressurestable KES-hose stainless steel hose clamp wrench size13 concrete wall 3-ribbed seal extension pipe wall insert Item Article code Spiral hose with a smooth inner surface, for gentle cable feeding inner diameter = 150 mm minimum length 1000 mm price per further 500 mm Hateflex 14150/1000 Connection sleeve for hose extension / connection of Hateflex 14150 KES-M 150 HTV System cover for pressure-tight connection of spiral hose Hateflex 14150 to wall insert HSI 150 KES-M 150-D Wall insert including blind cover for connecting HSI 150 system cover to end of spiral hose Hateflex 14150 KES-M 150-KVB System cover with 3 sockets and sleeve to seal 3 cables of diam 22 - 56 mm on end of spiral hose Hateflex 14150 KES-M 150-D3/58 System cover with 7 sockets and sleeve to seal 7 cables of diam 12-31 mm on end of spiral hose on Hateflex 14150 KES-M 150-D7/33 Sleeve to be used with interchangeable insert WE 160-z/d to seal cables on end of spiral hose Hateflex 14150 (installation before cables are pulled through) KES-M 150-WE Picture Cable entries Application: clamping nut system cover cable Pressure-tight connection of Hateflex 14150 to HSI 150-wall inserts Interchangeable insert to be used with sleeve KES-M 150-WE customized according to cables to be installed z= number of cables d= cable diameter WE 160-z/d heat shrink-fit sleeve rubber sleeve sliding and O-ring x = wall or masonry thickness Installation movie 16 cablespipesbuildingentries+ 17 Cable entry systems HSI 150 V-Guard KES-M 150 – Cable entry systems Cable entry systems HSI 150 V-Guard KES-M 150 – Cable entry systems V-CABLE HSI 150 – Accessories Item Article code Connection sleeve for connecting rigid cable ducts OD = 110 mm * to spiral hose Hateflex 14150 KES-M 150-M 110 1 set of clip rings to stabilize the corrugated pipe within the sleeve (kindly indicate pipe manufacturer and pipe type in your order) CR 110 Connection sleeve for connecting rigid cable ducts OD = 125 mm * to spiral hose Hateflex 14150 KES-M 150-M 125 1 set of clip rings to stabilize the corrugated pipe within the sleeve (kindly indicate pipe manufacturer and pipe type in your order) CR 125 Connection sleeve for connecting rigid cable ducts OD = 160 mm * to spiral hose Hateflex 14150 1 set of clip rings to stabilize the corrugated pipe within the sleeve (kindly indicate pipe manufacturer and pipe type in your order) Picture Flexible pin spanner Flexible pin spanner (buildings with perimeter insulation up to 100 mm) Sealing plug for system cover HSI 150-D7/33 Sealing plug for system cover HSI 150-D3/58 KES-M 150-M 160 KES-M 150-R 160 Spacer 2x3 for positioning of hose packages with Hateflex 14150 KES 150-2x3 KA * additional clip rings CR are necessary to connect corrugated pipes For each pipe connection 2 profile sealing rings are necessary (available from the pipe manufacturer, to be provided on-site). V-CABLE HSI 150 / KES 150 – Tool and assembly set 18 Article code Picture SLS 6G SLS 6GD VS 32/34 VS 58/60 Centering tape – set, consisting of 3 pieces elastomer strips 30 x 430 mm. For centering and fixing the cables into the system cover sockets for optimal shrinking. HSI-ZB 3-finger sleeve for system cover HSI 150-D7/33 AK.3F.44.13.16.4,2 3-finger sleeve for system cover HSI 150-D3/58 AK.3F.71.22.26.9 4-finger sleeve for system cover HSI 150-D7/33 AK.4F.44.19.20.7 4-finger sleeve for system cover HSI 150-D3/58 AK.4F.80.25.27.9 Lubricant 250 g GM Hot-melt tape, cold welding, length 3 m, width approx. 35 mm Hatetherm Cable cleaner, 500 ml can with screw cap. Suitable for environmentallyfriendly cleaning of cable sheating. KR 60 Cartridge of 300 ml colour: grey elastic sealant to optimize wall surface when used with sealing flange 1-component-sealant Sikaflex-11 FC Torque srewdriver (1,2 Nm) SEGMENTO with acoustic signal DMS CR 160 Rigid pipe section OD = 160 mm with sleeve for connection to spiral hose Hateflex 14150 (tight wall sealing in core drillings when used together with P-PIPE press seals). Item Item Cable entries V-Guard KES-M 150 – Cable entry systems Article code Tool set for pressure-tight strap assembly, consisting of 1 torque 4-20 Nm, ¼ inch, 1 extension 150 mm, ¼ inch, 1 socket for hexagon spanner SWS 13, ¼ inch Tool set KES-M Torque wrench (4-20 Nm) with extensions and Allen key Assembly set HSI 150-DG Picture cablespipesbuildingentries+ 19 Cable entry systems HSI 90 V-Body HSI 90 – Wall inserts, aluminium flange Cable entry systems HSI 90 V-Body HSI 90 – Wall inserts, aluminium flange V-Body HSI 90 – Wall inserts • waterproof concrete stress class 1 Item Features and technical data • single-sided connection to system sealing possible • minimum wall thickness 70 mm • available in individual thicknesses ≥ 70 mm • plug-in frame system for block assembly on-site • pressure-tight cover • pressure-tight up to 2 bar after concreting • connections to system sealing possible on both sides • minimum wall thickness 100 mm • available in individual wall thicknesses ≥ 100 mm • plug-in frame system for block assembly, available ex stock • pressure-tight cover on both sides • pressure-tight up to 2 bar after concreting frame size 145 x 145 mm 135 mm Single wall insert from wall thickness 70 mm Double wall insert from wall thickness 100 mm Picture HSI 90-K/X X = wall thickness in mm HSI 90-K2/X X = wall thickness in mm * for wall thicknesses > 500 mm prices on request 280 mm Wall insert – HSI 90-K2/X: 135 mm Wall insert – HSI 90-K/X: Article code Cable entries Application: 685 mm Example as a 2x5 block for 200 mm wall thickness: Article code: HSI 90-2x5-K2/200 Installation movie Double wall insert HSI 90 fixed as package into the formwork V-Body HSI 90 – Aluminium flange Application: non-standing seepage water, waterproof concrete stress class 1 Features and technical data Aluminium flange HSI 90-DF Sectional drawing Spacing dimensions Aluminium flange – HSI 90-DF: Min. 185 mm core drilling max. 90 mm diameter 20 Item Article code Aluminium flange incl. fastenings made of stainless steel V4A (AISI 316L) for stainless steel HSI 90-DF Cartridge of 300 ml colour: grey elastic sealant to optimize wall surface when used with sealing flange 1-component-sealant Sikaflex-11 FC Picture 185 mm 185 mm • connection to system sealing possible • aluminium flange with KTL (cataphoretic) - coating (optimum protection against corrosion) • for retrofit installation • core drilling max. 90 mm diameter • installation on container walls possible • including chloroprene (CR) surface seal, 10 mm thick and fastenings made of stainless steel V4A (AISI 316L) for concrete walls 46 mm 95 mm • 10 mm cablespipesbuildingentries+ 21 Cable entry systems HSI 90 V-Insert HSI 90 – System cover heat shrink method Cable entry systems HSI 90 V-Insert HSI 90 – System cover heat shrink method, accessories V-Insert HSI 90 – System cover heat shrink method Item Area of application cable/pipe diameter Article code System cover, closed - sealing cover Blind cover HSI 90-D System cover with 1 socket incl. 1 piece heat-shrink sleeve 1 piece centering tape 25 – 72 mm HSI 90-D1/75 System cover with 3 sockets incl. 3 pieces heat-shrink sleeves 12 – 30 mm HSI 90-D3/32 System cover with 6 sockets incl. 6 pieces heat-shrink sleeves 8 – 18 mm HSI 90-D6/20 Picture System cover heat shrink method – HSI 90-D1/75, -D3/32 and -D6/20: • wide application area • easy installation with bayonet catch • including centering tape at HSI 90-D1/75 • unused opening can be closed off with blind plugs VS 20, VS 32/34 respectively • also available in cold shrink-fit method • UV- and ozone resistant • resistant to transformer oil Cable entries Features and technical data Types with cold shrink sleeves available on request. V-CABLE HSI 90 – Accessories Item Transformer station entry: low-voltage cable sealed with HSI 90-D1/75 and HSI 90-D3/32 Application Sealing plug for system cover HSI 90-D6/20 Cross-section of a concrete wall flexible, pressurestable KES-hose stainless steel hose clamp wrench size13 extension pipe Picture VS 20 To seal unused sockets Sealing plug for system cover HSI 90-D3/32 concrete wall Article code VS 32/34 3-ribbed seal wall insert Centering tape – set, consisting of 3 pieces elastomer strips 30 x 430 mm clamping nut system cover cable HSI-ZB V-CABLE HSI 90 – Replacement -/ Repair heat shrink sleeves heat shrink-fit sleeve rubber sleeve For centering and fixing the cables into the system cover sockets for optimal shrinking. Item sliding and O-ring x = wall or masonry thickness Replacement heat shrink sleeves for HSI 90 Repair sleeves for HSI 90 for system cover Article code HSI 90-D1/75 TM2.200.92.25 HSI 90-D3/32 TM2.150.43.12 HSI 90-D6/20 TM2.150.25.8 HSI 90-D1/75 TMR3.250.84.20 HSI 90-D3/32 TMR3.250.53.13 HSI 90-D6/20 TMR3.250.34.10 Installation movie 22 cablespipesbuildingentries+ 23 Cable entry systems HSI 90 V-Insert HSI 90 – System cover for pipe connection Cable entry systems HSI 90 V-Guard HSI 90 – Cable duct connections V-Guard HSI 90 – Sleeve method for smooth and corrugated pipes Item Pipe outer diameter Article code System cover for smooth pipes 75 mm HSI 90-M 75 Picture Sleeve method – HSI 90 – M (pipe OD): Cold shrink method – HSI 90 – D/75-KS: • can be used with smooth and corrugated pipes • patented clip ring technology for sealing of corrugated pipes (indicate pipe type and pipe manu facturer, please) • mechanically stable, elastic connection using special sleeves and tightening straps made from stainless steel V4A (AISI 316L) • pressure-tight up to 0.5 bar, depending on the pipe / duct used • for corrugated pipes • shrink-fit method, no tools necessary • stress-free sealing for pressure-sensitive pipes • pressure-tight up to 0.5 bar, depending on the pipe / duct used System cover for smooth pipes System cover for corrugated pipes incl. clip rings System cover for smooth pipes System cover for corrugated pipes incl. clip rings Cable entries Features and technical data HSI 90-M 90 90 mm HSI 90-M 90-WR* HSI 90-M 110 110 mm HSI 90-M 110-WR* *Kindly indicate pipe manufacturer and pipe type in your order. For each pipe connection 2 profile sealing rings are necessary (available from the pipe manufacturer, to be provided on-site). V-Guard HSI 90 – Cold shrink sleeves for corrugated pipes Assembly of double wall insert HSI 90-K2 before concreting HSI 90-K2 after concreting: empty ducts will be installed subsequently Item Pipe outer diameter Article code System cover for corrugated pipes 75 mm HSI 90-D 75-KS Picture V-CABLE HSI 90 – Replacement cold shrink sleeves Item For system cover Article code Replacement cold shrink sleeves for HSI 90 HSI 90-D 75-KS KS 235.93.38 Connection of corrugated pipes HSI 90-D75 KS Installation movie 24 cablespipesbuildingentries+ 25 Cable entry systems HSI 90 V-Guard KES-M 90 – Cable entry systems Cable entry systems HSI 90 V-Guard KES-M 90 – Cable entry systems V-Guard KES-M 90 – Cable entry systems • waterproof concrete stress class 1 Features and technical data Cable entry system – KES-M 90: • pressure-tight ducting system up to 2.5 bar (outer pressure) for connection to the HSI 90-wall inserts • high mechanical stability • elastic connection with special system sleeves and straps made of stainless steel V4A (AISI 316L) • smooth inner surface for gentle cable feeding • sealing of cables with heat shrink or cold shrink sleeves or rubber press seals • adaptation with common cable ducts possible • also available as role commodity (up to a length of 25 m), extension possible with connection sleeve KES-M 90 HTV KES-M 90-D – Connection to the HSI 90 wall insert Flexible cable entry systems – extensions possible as necessary Cross-section of a concrete wall flexible, pressurestable KES-hose stainless steel hose clamp wrench size13 Item Article code Spiral hose with a smooth inner surface, for gentle cable feeding inner diameter = 90 mm minimum length 1000 mm price per further 500 mm Hateflex 14090/1000 Connection sleeve for hose extension / connection of Hateflex 14090 KES-M 90 HTV System cover for pressure-tight connection of spiral hose Hateflex 14090 to HSI 90 wall insert KES-M 90-D Wall insert including blind cover for connecting HSI 90 system cover to end of spiral hose Hateflex 14090 KES-M 90-KVB Sleeve to be used with interchangeable insert WE 100-z/d to seal cables to end of spiral hose Hateflex 14090 (installation before cables are pulled through) KES-M 90-WE Interchangeable insert to be used with sleeve KES-M 90-WE customized according to cables to be installed z= number of cables d= cable diameter Picture Cable entries Application: WE 100-z/d concrete wall 3-ribbed seal extension pipe wall insert clamping nut system cover cable KES-M 90-KVB – installation in slab heat shrink-fit sleeve rubber sleeve sliding and O-ring x = wall or masonry thickness Installation movie 26 cablespipesbuildingentries+ 27 Cable entry systems HSI 90 V-Guard KES-M 90 – Cable entry systems Cable entry systems HSI 90 V-Guard KES-M 90 – Cable entry systems V-CABLE HSI 90 – Accessories Item Article code Connection sleeve for connecting rigid cable ducts OD = 90 mm* to spiral hose Hateflex 14090 KES-M 90-M 90 1 set of clip rings to stabilize the corrugated pipe within the sleeve (kindly indicate pipe manufacturer and pipe type in your order) CR 90 Connection sleeve for connecting rigid cable ducts OD = 110 mm* to spiral hose Hateflex 14090 KES-M 90-M 110 Picture Item Article code Flexible pin spanner SLS 6G Flexible pin spanner (buildings with perimeter insulation up to 100 mm) SLS 6GD Sealing plug for system cover HSI 90-D6/20 VS 20 Sealing plug for system cover HSI 90-D3/32 VS 32/34 Centering tape – set, consisting of 3 pieces elastomer strips 30 x 430 mm HSI-ZB set of 3 3-finger sleeve for HSI 90-D3/32 AK.3F.44.13.16.4,2 4-finger sleeve for HSI 90-D3/32 AK.4F.44.19.20.7 1 set of clip rings to stabilize the corrugated pipe within the sleeve (kindly indicate pipe manufacturer and pipe type in your order) CR 110 Rigid pipe section OD = 90 mm with sleeve for connection to spiral hose Hateflex 14090 (tight wall sealing in core drillings when used together with P-PIPE press seals). KES-M 90-R 90 Lubricant 250 g GM Spacer 2x4 for positioning of hose packages with Hateflex 14090 KES 90-2x4 KA Hot-melt tape, cold welding, length 3 m, width approx. 35 mm Hatetherm Cable cleaner, 500 ml can with screw cap. Suitable for environmentally-friendly cleaning of cable sheating. KR 60 Cartridge of 300 ml colour: grey elastic sealant to optimize wall surface when used with sealing flange 1-component-sealant Sikaflex-11 FC * additional clip rings CR are necessary to connect corrugated pipes For each pipe connection 2 profile sealing rings are necessary (available from the pipe manufacturer, to be provided on-site). Picture Cable entries V-Guard KES-M 90 – Cable entry systems V-CABLE HSI 90/KES 90 – Tool set Item Article code Tool set for pressure-tight strap assembly, consisting of 1 torque 4-20 Nm, ¼ inch, 1 extension 150 mm, ¼ inch, 1 socket for hexagon spanner SWS 13, ¼ inch Tool set KES-M 28 Picture cablespipesbuildingentries+ 29 DIB Z-19 T-approv .1 a purs 5-1906 ( l . to D HSS) Z-19 IN 41 .1 0 purs 5-1792 ( 2-9 . to D HVS ) IN 41 02-9 Features and technical data Firewall S 90 – F-CABLE HVS / HSS: • fire protection S 90 • for core drillings 70 – 200 mm diameter • for plastic wall sleeves 80 – 200 mm diameter • for wall inserts HSI 150 (maximum package 2 x 6) • insulation thickness 280 mm • as of wall thickness 150 mm • no additional wall construction necessary • no limitation of individual cable diameters • pads assembly possible from one side • high flexibility for subsequent insertion • no additional coating of cables necessary HSS – installation fire-stop pads in wall insert HSI 150-K2, sealing with system cover or SEGMENTO Fire protection for cables F-CABLE HVS / HSS – Gas- and watertight firewall S 90 for installation in wall insert HSI 150, wall sleeves and core drillings F-CABLE HVS/HSS – Fire protections set and tools Item Core drilling/ wall sleeve diameter Article code Picture Approval no: Z-19.15-1906 – fire protection S 90, gastight Gastight fire protection set in connection with HRD consisting of: fire-stop pads 2x HVS-K250, 3x HVS-KB-60L, label, stainless steel belt up to diameter 100 mm HSS-100-KB/FR-HRD Gastight fire protection set in connection with HRD consisting of: fire-stop pads 2x HVS-K400, 2x HVS -K250, 3x HVS-KB-60L, label, stainless steel belt up to diameter 150 mm HSS-150-KB/FR-HRD Fire protection for cables Fire protection for cables F-CABLE HVS / HSS – Gas- and watertight firewall S 90 for installation in wall insert HSI 150, wall sleeves and core drillings Approval no: Z-19.15-1792 – fire protection S 90 HSS – installation in core drillings with HRD press seals Fire protection set consisting of: fire-stop pads 3x HVS -K250, 5x HVS-KB-60, 2x labels, 2x stainless steel belts up to diameter 100 mm HVS-KK 100 Fire protection set consisting of: fire-stop pads 2x HVS-K400, 5x HVS -K250/2, 6x HVS-KB-60, 1x label, 2x stainless steel belts up to diameter 150 mm HVS-KK 150 Fire protection set consisting of: fire-stop pads 2x HVS-K720, 2x HVS-K400, 5x HVS -K250, 8x HVS-KB-60, 1x label, 2x stainless steel belts up to diameter 200 mm HVS-KK 200 Assembly set 2 for installation of fire-stop pads in core drillings and wall inserts HSI 150 HVS-MS-2 Delivery without HRD rubber press seal. Application table HSS System HSS HRD 150/160 for HSI 150 SEG = SEGMENTO D / DG System cover Core drilling/wall sleeve (with HRD) Wall thickness in mm ≥ 150 ≥ 240 ≥ 240 ≥ 150 Cable configuration results from sealing system selection Total insulation thickness in mm 280 Size in mm after package formation HSI 150 (max. 2-row, 6 pieces in a row) Tightness in bar up to 2.5 0.5 up to 2.5 up to 5 Insulation thickness in mm 200 200 200 50 Cable type all cables and cross sections except for wave guides – no cable cross section limitation Installation in masonry, concrete or aerated concrete walls Comment configuration is limited by the sealing systems 30 440 F-CABLE universal fire-resistant sealing for cable entry HSI 150 440 280 Ø 70 (80) – 200 Item Sealing Article code Fire protection set consisting of: fire-stop pad 1x HVS-K720, 1x HVS-K400, 2x HVS -K250/2, 2x HVS-K250, 4x HVS-KB-60, label, stainless steel belt SEGMENTO Systemdeckel HSS-150/SEG/D/DG Fire protection set consisting of: fire-stop pads 2x HVS-K400, 3x HVS-K250, 3x HVS-KB-60L, label, stainless steel belt HRD-press seal HSS-150/HRD Picture Delivery without HRD rubber press seal, SEGMENTO respectively system cover. cablespipesbuildingentries+ 31 Press seals for cables P-CABLE Basic SG – Universal seal for cables Press seals for cables P-CABLE Basic SG – Universal seal for cables Application: P-CABLE Basic SG – Universal seal for cables • Core drilling/ wall sleeve ID Number of cables Cable diameter Article code 80 1 6 – 41 mm HRD 80-SG-1/6-41 1 24 – 52 mm HRD 100-SG-1/24-52 4 8 – 30 mm HRD 100-SG-4/8-30 8 4 – 16,5 mm HRD 100-SG-8/4-16,5 standing seepage water, pressing water, waterproof concrete stress class 1 Features and technical data Universal seal for cables – P-CABLE Basic SG: • absolutely gas- and watertight • sealing width 40 mm • split sealing for retrofit installation • segment ring technology – individual adjusting to installed cable diameters on-site • no loose components • complete with blind plugs • EPDM rubber • pressure plates made of stainless steel V2A (AISI 304L) • sturdy 5 mm pressure plates Picture 100 5 HRD 100-SG-2/8-30-3/4-16,5 of which 2 8 – 30 mm of which 3 4 – 16,5 mm 4 8 – 30 mm HRD 104-SG-4/8-30 1 24 – 54 mm HRD 104-SG-1/24-54 3 10 – 40 mm HRD 125-SG-3/10-40 6 6 – 31 mm HRD 125-SG-6/6-31 10 4 – 16,5 mm HRD 125-SG-10/4-16,5 1 12 – 75 mm HRD 150-SG-1/12-75 1 75 – 110 mm HRD 150-SG-1/75-110 3 22 – 54 mm HRD 150-SG-3/22-54 6 8 – 35 mm HRD 150-SG-6/8-35 9 6 – 25 mm HRD 150-SG-9/6-25 e.g. P-CABLE Basic HRD 80-SG-1/6-41 125 P-CABLE Basic HRD 150-SG installed in fibre cement wall sleeves P-CABLE Basic HRD 150-SG – 6/8-35 – individual adjusting to diameters of cables Press seals 104 e.g. P-CABLE Basic HRD 150-SG-3/22-54 150 10 HRD 150-SG-4/8-30-6/4-16,5 of which 4 8 – 30 mm of which 6 4 – 16,5 mm 7 HRD 200-SG-3/6-54-4/6-26 of which 3 6 – 54 mm of which 4 6 – 26 mm 200 15 Installation movie P-CABLE Basic SG 100 HRD 100-SG-4/8-30 32 HRD 200-SG-7/10-32-8/3,5-16,5 of which 7 10 – 32 mm of which 8 3,5 – 16,5 mm e.g. P-CABLE Basic HRD 200-SG-3/6-54-4/6-26 Installation movie P-CABLE Basic SG 150 HRD 150-SG-3/22-54 cablespipesbuildingentries+ 33 Press seals for cables P-CABLE Professional 1 (closed) und P-CABLE Professional 2 (split), sealing width 30 mm Press seals for cables P-CABLE Professional 1 (closed) and P-CABLE Professional 2 (split), sealing width 30 mm, EPDM with V2A (AISI 304L) Application: P-CABLE Professional 1 • Core drilling/ wall sleeve ID Optimal application range diameter Max. possible application range diameter * Closed design Article code 50 mm 0 – 25 mm 0 – 26 mm HRD 50-1-1/d 60 mm 0 – 32 mm 0 – 36 mm HRD 60-1-1/d 70 mm 0 – 40 mm 0 – 46 mm HRD 70-1-1/d 80 mm 0 – 50 mm 0 – 56 mm HRD 80-1-1/d 100 mm 0 – 63 mm 0 – 76 mm HRD 100-1-1/d 125 mm 63 – 90 mm 0 – 101 mm HRD 125-1-1/d 150 mm 90 – 112 mm 0 – 125 mm HRD 150-1-1/d 200 mm 110 – 162 mm 0 – 171 mm HRD 200-1-1/d 250 mm 160 – 210 mm 0 – 214 mm HRD 250-1-1/d standing seepage water, pressing water, waterproof concrete stress class 1 Features and technical data P-CABLE Professional: • absolutely gas- and watertight • sealing width 30 mm • closed or split • different outer diameters can be manufactured exactly to customers‘ requirements • easy to mount • optionally available with overlapping flange (F) or eccentric • suitable for one or more cables • for core drillings/wall sleeves from diameter 25 mm • suitable for sealing rigid cable ducts • EPDM, NBR or silicone rubber • pressure plates made from stainless steel V2A (AISI 304L), optionally V4A (AISI 316L) • sturdy 5 mm pressure plates Customized diameters available Picture d = cable diameter Press seals For maximum cable configuration please refer to table on page 34. P-CABLE Professional 2 P-CABLE Professional 2: HRD 150-1G sealing several cables per core drilling / wall sleeve P-CABLE Professional 2: HRD 200-1G installed in a steel pipe Configuration table Number = Z cables/pipes Core drilling Core drilling Core drilling Core drilling Core drilling Core drilling Core drilling diameter HRD 50 diameter HRD 80 diameter HRD 100 diameter HRD 125 diameter HRD 150 diameter HRD 200 diameter HRD 250 Core drilling/ wall sleeve ID Optimal application range diameter Max. possible application range diameter * Split design Article code 50 mm 0 – 25 mm 0 – 26 mm HRD 50-1G-1/d 60 mm 0 – 32 mm 0 – 36 mm HRD 60-1G-1/d 70 mm 0 – 40 mm 0 – 46 mm HRD 70-1G-1/d 80 mm 0 – 50 mm 0 – 56 mm HRD 80-1G-1/d 100 mm 0 – 63 mm 0 – 76 mm HRD 100-1G-1/d 125 mm 63 – 90 mm 0 – 101 mm HRD 125-1G-1/d 150 mm 90 – 112 mm 0 – 125 mm HRD 150-1G-1/d 200 mm 110 – 162 mm 0 – 171 mm HRD 200-1G-1/d 250 mm 160 – 210 mm 0 – 214 mm HRD 250-1G-1/d Customized diameters available Picture d = cable diameter For maximum cable configuration please refer to table on page 34. Cable/pipe diameter = dmax 1 26 56 76 101 125 171 214 2 16 31 41 53 66 91 116 3 14 28 37 49 60 84 107 4 12 24 32 43 53 74 95 5 8 21 28 38 47 65 84 6 5 18 25 33 42 58 75 7 - 15 21 32 39 56 73 Note: Prices apply for P-CABLE Professional 1 and P-CABLE Professional 2 with one drilling each. Additional drillings on request. Further variants: P-CABLE Professional 5, blind insert, article code: e.g. HRD 117-1-0 P-CABLE Professional 3, split, eccentric sealing insert, article code: e.g. HRD 156-1G-1/45-ex-23 All P-CABLE Professional-variants also available with overlapping flange. Further sizes up to diameter 1,500 mm available on short notice upon request. Installation instructions 34 cablespipesbuildingentries+ 35 Press seals for cables P-CABLE Professional 1 (closed) und P-CABLE Professional 2 (split), sealing width 60 mm Press seals for cables P-CABLE Professional 1 (closed) and P-CABLE Professional 2 (split), sealing width 60 mm, EPDM with V2A (AISI 304L) P-PIPE Professional 1 Application: • standing seepage water, pressing water, high stress (chemical, thermal), difficult installation conditions, waterproof concrete stress class 1 Features and technical data P-CABLE Professional: • absolutely gas- and watertight • sealing width 60 mm • closed or split • different outer diameters can be manufactured exactly to customers‘ requirements • easy to mount • optionally available with overlapping flange (F) or eccentric • suitable for one or more cables • for core drillings/wall sleeves from diameter 25 mm • EPDM, NBR or silicone rubber • pressure plates made from stainless steel V2A (AISI 304L), optionally V4A (AISI 316L) • sturdy 5 mm pressure plates Core drilling/ wall sleeve ID Optimal application range diameter Max. possible application range diameter * Closed design Article code 50 mm 0 – 25 mm 0 – 26 mm HRD 50-2-1/d 60 mm 25 – 32 mm 0 – 36 mm HRD 60-2-1/d 70 mm 25 – 40 mm 0 – 46 mm HRD 70-2-1/d 80 mm 25 – 50 mm 0 – 56 mm HRD 80-2-1/d 100 mm 25 – 63 mm 0 – 76 mm HRD 100-2-1/d 125 mm 63 – 90 mm 0 – 101 mm HRD 125-2-1/d 150 mm 90 – 112 mm 0 – 125 mm HRD 150-2-1/d 200 mm 110 – 162 mm 0 – 171 mm HRD 200-2-1/d 250 mm 160 – 210 mm 0 – 214 mm HRD 250-2-1/d Customized diameters available Picture d = cable diameter Press seals For maximum cable configuration please refer to table on page 36. P-PIPE Professional 2 P-CABLE Professional 5: HRD 100-2-0 blind insert P-CABLE Professional 2: HRD 150-2G-2/18-2/27 Configuration table Number = Z Cables/pipes Core drilling diameter HRD 50 Core drilling diameter HRD 80 Core drilling Core drilling Core drilling Core drilling Core drilling diameter HRD 100 diameter HRD 125 diameter HRD 150 diameter HRD 200 diameter HRD 250 Core drilling/ wall sleeve ID Optimal application range diameter Max. possible application range diameter * Split design Article code 50 mm 0 – 25 mm 0 – 26 mm HRD 50-2G-1/d 60 mm 25 – 32 mm 0 – 36 mm HRD 60-2G-1/d 70 mm 25 – 40 mm 0 – 46 mm HRD 70-2G-1/d 80 mm 25 – 50 mm 0 – 56 mm HRD 80-2G-1/d 100 mm 25 – 63 mm 0 – 76 mm HRD 100-2G-1/d 125 mm 63 – 90 mm 0 – 101 mm HRD 125-2G-1/d 150 mm 90 – 112 mm 0 – 125 mm HRD 150-2G-1/d 200 mm 110 – 162 mm 0 – 171 mm HRD 200-2G-1/d 250 mm 160 – 210 mm 0 – 214 mm HRD 250-2G-1/d Customized diameters available Picture d = cable diameter For maximum cable configuration please refer to table on page 36. Cable/pipe diameter = dmax 1 26 56 76 101 125 171 214 2 16 31 41 53 66 91 116 3 14 28 37 49 60 84 107 4 12 24 32 43 53 74 95 5 8 21 28 38 47 65 84 6 5 18 25 33 42 58 75 7 - 15 21 32 39 56 73 Note: Prices apply for P-CABLE Professional 1 and P-CABLE Professional 2 with one drilling each. Additional drillings on request. Further variants: P-CABLE Professional 5, blind insert, article code: e.g. HRD 117-2-0 P-CABLE Professional 3, split, eccentric sealing insert, article code: e.g. HRD 137-2G-1/39-ex-20 All P-CABLE Professional-variants also available with overlapping flange. Further diameters up to 1,500 mm available on short notice upon request. Installation instructions 36 cablespipesbuildingentries+ 37 Wall sleeves P-LINER Basic SFR – Renovation wall sleeve Wall sleeves P-LINER Basic SFR – Renovation wall sleeve P-LINER Basic SFR – Renovation wall sleeve Application: Medium pipe non-standing seepage water Wall sleeve Wall sleeve ID OD Features and technical data Renovation wall sleeve – P-LINER Basic SFR: • for subsequent installation in wall break-throughs, core drillings or rectangular openings • breaking resistant, dimensionally stable • can easily be shortened to required length • suitable for all wall types except for waterproof concrete • roughened surface will homogeneously connect to mortar • compact design allows for smallest possible drillings / break throughs • dimensions: SFR 100: ID = 100 mm, OD = 110 mm SFR 150: ID = 150 mm, OD = 162 mm SFR 200: ID = 200 mm, OD = 214 mm Roughened surface 38 wall thickness 4,5 u. 6 mm min. 20 mm mortar all around interior diam. plastic-modified, bitumin thick coating with rounded groove Optimum application range OD Maximum poss. area of application OD * Minimum drilling Length Article code 100 mm 110 mm 0 – 63 mm 0 – 76 mm 150 mm 300 mm SFR 100/300 100 mm 110 mm 0 – 63 mm 0 – 76 mm 150 mm 500 mm SFR 100/500 100 mm 110 mm 0 – 63 mm 0 – 76 mm 150 mm 1000 mm SFR 100/1000 150 mm 162 mm 90 – 112 mm 0 – 125 mm 200 mm 300 mm SFR 150/300 150 mm 162 mm 90 – 112 mm 0 – 125 mm 200 mm 500 mm SFR 150/500 150 mm 162 mm 90 – 112 mm 0 – 125 mm 200 mm 1000 mm SFR 150/1000 200 mm 214 mm 110 – 162 mm 0 – 171 mm 250 mm 300 mm SFR 200/300 200 mm 214 mm 110 – 162 mm 0 – 171 mm 250 mm 500 mm SFR 200/500 200 mm 214 mm 110 – 162 mm 0 – 171 mm 250 mm 1000 mm SFR 200/1000 Picture SFR 100/500 Press seals • For maximum cable configuration please refer to table on page 36. SFR - installation according to DIN 18195, part 4 cablespipesbuildingentries+ 39 Wall sleeves Special solutions Wall sleeves Special solutions Special solutions after Existing rectangular opening has to be subsequently sealed Rectangular split flange for several cable penetrations Split fibre cement wall sleeve FZR-G Fixed and loose flange P-LINER Professional HRD (D)-FUFA for sealing according to DIN 18195 part 6 Slanted core drilling in porous wall Fixed/loose flange with slanted empty hose connection and surface sealing Split multiple HRD flange P-LINER Professional HRD (2xD)-FG Closed HRD flange P-LINER Professional HRD (D)-F Entry of high-voltage cables and cable ducts have to be subsequently sealed in a shaft wall Split fixed/loose flange according to DIN 18195 Two-level fixed/loose flange P-LINER Professional HRD (D)-FUFFA for sealing according to DIN 18195 part 5 Double wall insert HSI 150-K2F/x for sealing according to DIN 18195 part 6 40 cablespipesbuildingentries+ Press seals before Special solutions 41 Earthing fixed points HEA – Entry for earthing Earthing fixed points HEA – Entry for earthing HEA / HEA-E – Entry for earthing in concrete Application: waterproof concrete stress class 1 Item Features and technical data Entry for earthing in concrete – HEA / HEA-E: water barrier Wassersperre Ø 25 mm protective cover Schalungsscheibe Ø 72 mm • conductor core Ø 25 mm with a threaded connection on both sides M12, made of stainless steel V4A (AISI 316L), HEA-E also available with connecting thread M16 • pressure-tight water barrier (profiled rubber flange, NBR) • contact plates Ø 72 mm made of stainless steel V4A (AISI 316L) • protective covers made of PE with four nail holes • HEA wall thickness 70-200 mm • HEA-E wall thickness > 200 mm • conductor core for HEA-E connection via M16 bolts, galvanised • no twisting after installation in concrete • according to DIN 18014, DIN EN 62305-3 VDE 0185-305-3 (with lightning protection) 10 mm thread M12 Gewinde M12 Picture HEA-M12/70 HEA-M12/100 HEA-M12/150 e.g. HEA-M12/100 HEA-M12/200 HEA-E-M12/X HEA-E-M16/X e.g. HEA-E-M12/240 X = wall thickness in mm Increments of 10 mm possible Installation instructions HEA-IS-M12 – Insulated feedthrough for station earthing Application: • Entry for earthing connections made of stainless steel V4A (AISI 316L), connection M 12 on both sides, with water barrier and protective foils, for wall thickness 70 mm Entry for earthing connections made of stainless steel V4A (AISI 316L), connection M 12 on both sides, with water barrier and protective covers, for wall thickness 100 mm Entry for earthing connections made of stainless steel V4A (AISI 316L), connection M 12 on both sides, with water barrier and protective covers, for wall thickness 150 mm Entry for earthing connections made of stainless steel V4A (AISI 316L), connection M 12 on both sides, with water barrier and protective covers, for wall thickness 200 mm Entry for earthing connections made of stainless steel V4A (AISI 316L), connection M 12 on both sides, with water barrier and protective covers, available for wall thicknesses 210 - 500 mm Entry for earthing connections made of stainless steel V4A (AISI 316L), connection M 16 on both sides, with water barrier and protective covers, available for wall thicknesses 210 - 500 mm Article code waterproof concrete stress class 1 Features and technical data water barrier Wassersperre Insulated entry for substation construction – HEA-IS-M12: Ø 72 mm • conductor core Ø 25 mm with a threaded connection on both sides M12, made of stainless steel V2A (AISI 304L) • pressure-tight water barrier (profiled rubber flange, EPDM) • contact plates Ø 72 mm made of stainless steel V2A (AISI 304L) • with protective cover • minimum wall thickness HEA-IS: 70 mm • according to VDE 0101, EN 50522 Ø 25 mm protective cover Schutzabdeckung thread M12 Gewinde M12 min. wall thickness7070mm mm mind. Wandstärke Item Article code Feedthrough for earthing connections made of stainless steel V2A (AISI 304L), connection M12 on both sides, with water barrier and protective cover (HEA-IS-M12) for wall thickness 100 mm HEA-IS-M12/100 Feedthrough for earthing connections made of stainless steel V2A (AISI 304L), connection M12 on both sides, with water barrier and protective cover (HEA-IS-M12) for wall thickness 150 mm HEA-IS-M12/150 Feedthrough for earthing connections made of stainless steel V2A (AISI 304L), connection M12 on both sides, with water barrier and protective cover (HEA-IS-M12) for wall thickness 200 mm HEA-IS-M12/200 Feedthrough for earthing connections made of stainless steel V2A (AISI 304L), connection M12 on both sides, with water barrier and protective cover (HEA-IS-M12) for wall thickness 250 mm HEA-IS-M12/250 Picture HEA-IS-M12/100 eXtra • Increments of 10 mm possible HEA-PK-M12 – Earthing connection and entry Application: • waterproof concrete stress class 1 Item Features and technical data 42 thread GewindeM12 M12 oder M16 or M16 Schalungsscheibe contact plate Increments of 10 mm possible Ø 25 mm • conductor core Ø 25 mm with a threaded connection on both sides M12/M16, made of stainless steel V4A (AISI 316L) • terminal lug with cross clamp 70 x 70 mm made of steel St37, galvanised • pressure-tight water barrier (profiled rubber flange, NBR) • contact plates Ø 72 mm made of stainless steel V4A (AISI 316L) • protective covers made of PE with four nail holes • minimum wall thickness 200 mm • conductor core connection with M16 threaded bolts, galvanised • according to DIN 18014, DIN EN 62305-3 VDE 0185-305-3 (with lightning protection) water barrier Wassersperre Ø 72 mm Earthing connection and entry – HEA-PK-M12 / HEA-PK-M16: cross-clamp for connecting strip Kreuzklemme irons up to zum Anschluss von 40 x Bandeisen 4 mm 40 x 4 mm rod mm Rd.8-12 8/12 mm Entry for earthing connections made of stainless steel V4A (AISI 316L), connection M12 on both sides, with terminal lug and cross clamp, available for wall thicknesses 150 - 500 mm, with water barrier and protective covers Entry for earthing connections made of stainless steel V4A (AISI 316L), connection M16 on both sides, with terminal lug and cross clamp, available for wall thicknesses 150 - 500 mm, with water barrier and protective covers thread M12 Gewinde M12 or M16 oder M16 Article code Picture HEA-PK-M12/X HEA-PK-M16/X X = wall thickness in mm Short circuit-proof up to 10 KA/1s (VDE 0101/E DIN EN 50522) min.mind. wallWandstärke thickness150 150 mmmm cablespipesbuildingentries+ 43 Earthing fixed points Connection part with cross clamp, weld groove, welded or clamped connection Earthing fixed points Connection part with cross clamp, weld groove, welded or clamped connection HEA-P-M12 / HEA-P-M16 – Connection part with cross clamp Application: • waterproof concrete stress class 1 Features and technical data contact plate Schalungsscheibe Ø 72 mm • conductor core, Ø 25 mm with threaded connection M12 /M16 made of stainless steel V4A (AISI 316L) • cross clamp 70 x 70 mm with threaded bolt M12 or M16 galvanised • contact plate Ø 72 mm made of stainless steel V4A (AISI 316L) • protective cover made of PE with four nail holes • minimum wall thickness 200 mm • distance between formwork and earth connection approximately 120 mm • according to DIN 18014, DIN EN 62305-3 VDE 0185-305-3 (with lightning protection) Ø 25 mm Connection part with cross clamb – HEA-P-M12 / HEA-P-M16: cross-clamp for Kreuzklemme connecting strip zum Anschluss irons up to von Bandeisen bisx40 x 4 mm 40 4 mm Rd. 8/12 mm rod 8-12 mm Connection part with screwed-on crossclamp for the connection in concrete, connection M12, made of stainless steel V4A (AISI 316L), with protective cover, installation length = 120 mm HEA-P-M12 Connection part with screwed-on crossclamp for the connection in concrete, connection M16, made of stainless steel V4A (AISI 316L), with protective cover, installation length = 120 mm HEA-P-M16 Picture HEA-P-M12 min.mind. wallWandstärke thickness 200 200mm mm HEA-A-M12 – Connection part with weld groove waterproof concrete stress class 1 Features and technical data Item Article code Connection part made of stainless steel V2A (AISI 304L) with weld groove made of steel St 37, conductor core Ø 25 mm, connection M12, for distances between formwork and the core iron 50 mm HEA-A-M12/50 Picture HEA-A-M12/50 Ø 25 mm Ø 72 mm Connection part with weld groove – HEA-A-M12: weld groove Schweißnut thread M12 Gewinde M12 eXtra • conductor core, Ø 25 mm with threaded connection M12 made of stainless steel V2A (AISI 304L) • connection part with welded groove made of steel St37 to connect with 10 – 12 mm round steel • contact plate Ø 72 mm made of stainless steel V2A (AISI 304L) • protective foil green transparent • distance between formwork and the core iron 50 mm Article code thread M12 Gewinde M12 or M16 oder M16 Application: • Item distance tozur reinAbstand Armierung 50 50 mm forcement mm min. wall thickness 100 100mm mm mind. Wandstärke abhängigon von der depending exposure Beton-Expositionsklasse class of concrete Connection part with welded or clamped connection Application: • waterproof concrete stress class 1 Features and technical data Connection part with welded or clamped connection – HEA-S-M12 / HEA-S-M16: contact plate Schalungsscheibe Item Article code Connection part made of stainless steel V4A (AISI 316L) with screwed-on steel rod made of steel St 37, Ø 12 mm, connection M12, for welded or clamped connection in concrete HEA-S-M12 Connection part made of stainless steel V4A (AISI 316L) with screwed-on steel rod made of steel St 37, Ø 12 mm, connection M16, for welded or clamped connection in concrete HEA-S-M16 Picture 44 Ø 25 mm Ø 72 mm cross-clamp for • conductor core, Ø 25 mm with threaded connection M12/M16 made of stainless steel V4A (AISI 316L) • steel rod Ø 12 mm made of steel St37 for welded or clamped connection in concrete • contact plate Ø 72 mm made of stainless steel V4A (AISI 316L) • protective covers made of PE with four nail holes • according to DIN 18014, DIN EN 62305-3 VDE 0185-305-3 (with lightning protection) Kreuzklemme connecting strip zum Anschluss ironsBandeisen up to von bis 40 x 5 mm 40 x 5 mm Rd. rod 8/12 8-12mm mm nicht im Liefernot included umfang enthalten HEA-S-M12 thread M12 Gewinde M12 cablespipesbuildingentries+ 45 Earthing fixed points HEA-N, HEA-W, HEA-EW – Entry Earthing fixed points HEA-N, HEA-W, HEA-EW – Entry HEA-N – Entry for subsequent installation Application: • waterproof concrete stress class 1 Item Article code Entry for earthing connections, M16, stainless steel V4A (AISI 316L), for wall thicknesses up to 200 mm for subsequent installation HEA-N-M16/200 Entry for earthing connections, M16, stainless steel V4A (AISI 316L), for wall thicknesses up to 600 mm for subsequent installation HEA-N-M16/600 Picture Features and technical data Entry for subsequent installation – HEA-N: Abdichtung sealing • M16 threaded rod made of stainless steel V4A (ASI 316L) with sealing on both sides • contact plate Ø 72 mm made of stainless steel V4A (AISI 316L) • terminal lug with cross clamp for FL 40 x 4 mm or rod 10 – 12 mm • suitable for wall thicknesses up to 600 mm, bigger wall thicknesses on request • suitable for bore holes Ø 18 – 22 mm • according to DIN 18014, DIN EN 62305-3 VDE 0185-305-3 (with lightning protection) threaded rod M16 Gewindestange cross-clamp for Kreuzklemme connecting strip zum Anschluss irons up to von Bandeisen mm 40 xx 44 mm 3,5mm mm 30 xx 3,5 Rd. 10-12 10 - 12 mm rod mm mind. 200200 mm mm min. Wandstärke wall thickness Entry for earthing connections, M16, stainless steel V4A (AISI 316L), for walls with perimeter insulation up to 200 mm, for wall thicknesses up to 400 mm for subsequent installation HEA-N-M16/X HEA-ND-M16/400 X = wall thickness in mm HEA-W – Entry for “black tank” Application: • standing seepage water, pressing water, waterproof concrete stress class 1 Features and technical data • for buildings with watertight external sealing according to DIN 18195 part 6, manufactured according to DIN 18195 part 9 (fixed/loose flange, Ø 210 mm) • conductor core Ø 25 mm made of stainless steel V4A (AISI 316L) with threaded connection on both sides M12/M16 and additional cross clamp M20 as an external connection made of stainless steel V4A (ASI 316L) • conductor core connection with M16 threaded bolts and lock nuts, galvanised • contact plates Ø 72 mm made of stainless steel V4A (AISI 316L) • protective covers made of PE with four nail holse • minimum wall thickness 180 mm • according to DIN 18014, DIN EN 62305-3 VDE 0185-305-3 (with lightning protection) inside of building Gebäudeaußenseite Gebäudeinnenseite outside of building fixed flange Festflansch Losflansch loose flange Anschlussbolzen connecting bolt M12 oder M16 M12 or M16 bolt 30 x 30 mm Bolzen 30 x 30 mm insulated isoliert membrane Dichtbahn cross-clamp for Kreuzklemme connecting strip zum Anschluss ironsvon upBandeisen to 40 x 4 mm 40 xbis 4 mm Rd. 8-12 mm rod 8-12 mm Armierungsstahl reinforcing steel bolt ØØ25 mm Bolzen 25 mm thread M12 Gewinde M12 M16 oroder M16 Entry HEA-W/x for buildings with watertight external sealing according to DIN 18195 part 6, manufactured according to DIN 18195 part 9 (fixed/ loose flange, Ø 210 mm), internal connection M12, cross clamp with threaded bolt M20 (min. wall thinkness 180 mm) HEA-W-M12/X Entry HEA-W/x for buildings with watertight external sealing according to DIN 18195 part 6, manufactured according to DIN 18195 part 9 (fixed/ loose flange, Ø 210 mm), internal connection M16, cross clamp with threaded bolt M20 (min. wall thickness 180 mm) HEA-W-M16/X Picture HEA-W-M12/X X = wall thickness in mm mind. Wandstärke 180 180 mm mm min. wall thickness Application: • Article code eXtra Entry for „black bath“ – HEA-W: Item HEA-EW – Entry for double wall / element wall waterproof concrete stress class 1 Item Article code Entry for earthing connections made of stainless steel V4A (AISI 316L), connection M12 on both sides, with 3 water barriers and protective covers (min. wall thickness 170 mm) HEA-EW-M12/X Picture Features and technical data Entry for double wall /element wall – HEA-EW-M12: 46 HEA-EW-M12/X Schalungsscheibe protective cover X = wall thickness in mm Ø 25 mm Wassersperre water barrier Ø 72 mm • conductor core Ø 25 mm with a threaded connection on both sides M12 made of stainless steel V4A (AISI 316L) • conductor core connection with M16 threaded bolts, galvanised • 2 water barriers (profiled rubber flange, NBR) and 1 additional seal on the threaded bolt, the position of which can be adapted on site • contact plates Ø 72 mm made of stainless steel V4A (AISI 316L) • protective covers made of PE with four nail holes • minimum wall thickness 170 mm • according to DIN 18014, DIN EN 62305-3 VDE 0185-305-3 (with lightning protection) thread M12 Gewinde M12 mm mm min.mind. wallWandstärke thickness170170 cablespipesbuildingentries+ 47 Earthing fixed points HEA-F/HEA-PF – Entry for flexible earthing connections, accessories HEA-F/HEA-PF – Entry for flexible earthing connections Application: • Earthing fixed points HEA-F/HEA-PF – Entry for flexible earthing connections, accessories waterproof concrete stress class 1 Item Article code Flexible, insulated earthing entry and copper (Cu) ground strap 50 mm² with connecting thread M12 for wall thicknesses up to 600 mm HEA-F-M12/600 Flexible, insulated earthing entry and copper (Cu) ground strap 50 mm² with connecting thread M16 for wall thicknesses up to 600 mm HEA-F-M16/600 Flexible earthing entry with steel cable Ø 10 mm galvanised and connecting thread M12 for wall thicknesses up to 600 mm HEA-PF-M12/600 Flexible earthing entry with steel cable Ø 10 mm galvanised and connecting thread M16 for wall thicknesses up to 600 mm HEA-PF-M16/600 Picture Features and technical data Entry for flexible earthing connections – HEA-F (insulated) / HEA-PF: steel cable 10 mm Stahlseil Ø 10Ømm Ø 25 mm protective cover Schalungsscheibe Ø 25 mm thread GewindeM12 M12 oder M16 or M16 100 mm Ø 72 mm Ø 72 mm • conductor core Ø 25 mm made of stainless steel V4A (AISI 316L) with threaded connection on both sides M12 or M16 • pressure-tight water barrier (profiled rubber flange, NBR) • contact plate Ø 72 mm made of stainless steel V4A (AISI 316L) • protective covers made of PE with four nail holes • for wall thicknesses up to 600 mm, bigger wall thicknesses on request • HEA-F: Cu ground strap 50 mm2, finely stranded, insulated • HEA-PF: steel cable dia. 10 mm, galvanized. Can be fastened to reinforcement bars with cross clamp Z-K40-St37 fvz • according to DIN 18014, DIN EN 62305-3 VDE 0185-305-3 (with lightning protection) 100 mm thread M12 Gewinde M12 oder M16 or M16 min. thickness 150 mind.wall Wandstärke 150 mm mm max. thickness 600 600mm mm max.wall Wandstärke type: HEA-PF Accessories Accessories Connection bolt M12 with washer, lock washer and screw nut made of material St37 zinc-plated Connection bolt M16 with washer, lock washer and screw nut made of material St37 zinc-plated Connection bolt M12 with washer, lock washer and screw nut made of stainless steel V4A (AISI 316L) Connection bolt M16 with washer, lock washer and screw nut made of stainless steel V4A (AISI 316L) Article code Jumper cable strap for connecting foundation earthing lines in the vicinity of expansion joints, length 180 mm, material: Cu 50 mm² (finely-stranded) Z-ÜB-M12-Cu Flexible bonding for connecting foundation earthing lines in the vicinity of expansion joints and for connecting metal cladding, length 300 mm, material: Cu 16 mm² (multi-stranded) Z-ÜS-M12-Cu/300 Terminal lug for connecting earthing conductors, equipotential busbar or lightning protection technology, lug stainless steel V4A (AISI 316L), with connecting screw M12 Z-AL30-M12 Terminal lug for connecting earthing conductors, equipotential busbar or lightning protection technology, lug stainless steel V4A (AISI 316L), with connecting screw M16 Z-AL40-M16 Hot-melt tape, cold-welding, length 3 m, width approximately 35 mm, eminently suitable as corrosion protection for earthing connectors Hatetherm Picture Picture Z-B-M12-St37 Z-B-M16-St37 Z-B-M12-V4A Z-B-M16-V4A Four-wire connector with screwed-on threaded bolt M12 made of material St37 zinc-plated Z-KG-M12-fvz Four-wire connector with screwed-on threaded bolt M12 made of stainless steel V4A (AISI 316L) Z-KG-M12-V4A Four-wire connector with screwed-on threaded bolt M16 made of stainless steel V4A (AISI 316L) Z-KG-M16-V4A Four-wire connector with screwed-on threaded bolt M12 made of stainless steel V4A (AISI 316L) for buildings with perimeter insulation up to 80 mm Z-KG-D-M12-V4A Four-wire connector with screwed-on threaded bolt M16 made of stainless steel V4A (AISI 316L) for buildings with perimeter insulation up to bis 80 mm Z-KG-D-M16-V4A Connection terminal 70 x 70 mm made of St37 zinc-plated for flat belt 40 x 4 mm or circular conductor connection 8 – 12 mm Z-K40-St37-fvz Connection terminal 70 x 70 mm made of stainless steel V4A (AISI 316L) for flat belt 40 x 4 mm or circular conductor connection 8 – 12 mm Z-K40-V4A 48 Article code Z-B-M12-St37 eXtra Item Item Z-KG-M12-V4A Z-KG-D-M12 Z-K40-V4A cablespipesbuildingentries+ 49 Foundation pipes HFR – Foundation pipes for lamp posts Foundation pipes HFR – Foundation pipes for lamp posts, accessories HFR – Foundation pipes for lamp posts Item Features and technical data Article code Picture Foundation pipe: ID = 290 mm, OD = approximately 335 mm Foundation pipes for lamp posts – HFR: • foundation pipe, for masts, fence posts, flag posts etc. • low weight, thus easy handling • ribbed plastic design • resistant to corrosion and chemicals • high stability and long service life • available in nominal diameters 300, 400 and 500 mm • individual lengths available • cover available as protection against dirt (not included in scope of delivery) • posts can be installed at any point in time during construction • damaged posts can easily be replaced HFR300/600/85/400 Foundation pipe, pipe length = 800 mm HFR300/800/85/600 Foundation pipe, pipe length = 1000 mm HFR300/1000/85/600 Foundation pipe, pipe length = 1200 mm HFR300/1200/85/600 Foundation pipe: ID = 390 mm, OD = approximately 450 mm Article code, e.g.: HFR 300 / 1200 / 85 / 750 hole position from outer edge in mm (Y) hole diameter in mm 85 Foundation pipe, pipe length = 600 mm length in mm (X) Technical details nominal diameter Foundation pipe, pipe length = 800 mm HFR400/800/85/600 Foundation pipe, pipe length = 1000 mm HFR400/1000/85/600 Foundation pipe, pipe length = 1200 mm HFR400/1200/85/600 Foundation pipe, pipe length = 1400 mm HFR400/1400/85/600 Foundation pipe: ID = 490 mm, OD = approximately 560 mm Foundation pipe, pipe length = 800 mm HFR500/800/85/600 Foundation pipe, pipe length = 1000 mm HFR500/1000/85/600 Foundation pipe, pipe length = 1200 mm HFR500/1200/85/600 Foundation pipe, pipe length = 1400 mm HFR500/1400/85/600 Foundation pipe, pipe length = 1600 mm HFR500/1600/85/600 lean concrete soil filling material e.g. sand eXtra lamp post Accessories Item Article code PE cover for HFR 300 for protecting against dirt HFR 300-D PE cover for HFR 400 for protecting against dirt HFR 400-D PE cover for HFR 500 for protecting against dirt HFR 500-D duct supply line lean concrete Sectional view 50 cablespipesbuildingentries+ 51 Roof entry SHD – Swan neck roof entry Roof entry SHD – Swan neck roof entry SHD – Swan neck roof entry Features and technical data Swan neck roof entry – SHD: • flexible, modular system suitable for all flat roof structures • individual components, thus low transport weight • height (min. 300 mm) and orientation can be adjusted (can be swivelled through 360°) even after installation • available in 4 sizes, 100, 150, 200 and 300 mm diameters • all steel parts are hot-dip galvanized • sealing of cables in swan neck after installing the cables possible with split sealing insert SKD (pressure plates made of stainless steel V2A (AISI 304L), rubber quality EPDM) pipe elbow 30°30 ° Rohrbogen pipe elbow Rohrbogen 9090° ° B 200 intermediate pipe Zwischenstück (can be removed) (demontierbar) drip cap Abtropfhaube header Grundrohr membrane Dichtbahn A (mm) B (mm) C ( mm) D (ID mm) E ( mm) SHD 100 600 – 950 1050 – 1400 250 100 300 SHD 150 600 – 950 1175 – 1525 300 150 350 SHD 200 600 – 950 1300 – 1650 350 200 400 SHD 300 600 – 950 1550 – 1900 450 300 500 A = min./max. telescope range B = overall height C = hole pattern 4 x 12 mm diameter D = max. core drilling diameter E = base plate edge dimension 500 A height-adjustable höhenverstellbares extension pipe Verlängerungsrohr Typ Item Article code Swan neck roof entry, ID=100 mm, for dowelling above core drilled holes, rotatable by 360°, height-adjustable SHD 100 Swan neck roof entry, ID=150 mm, for dowelling above core drilled holes, rotatable by 360°, height-adjustable SHD 150 Swan neck roof entry, ID=200 mm, for dowelling above core drilled holes, rotatable by 360°, height-adjustable SHD 200 Swan neck roof entry, ID=300 mm, for dowelling above core drilled holes, rotatable by 360°, height-adjustable SHD 300 Picture SKD – Cable sealing for swan neck Item Article code Seal insert, for swan neck SHD 100 (pressure plates made of stainless steel V2A (AISI 304L), rubber quality EPDM) SKD 100-2G-Z/d Seal insert, for swan neck SHD 150 (pressure plates made of stainless steel V2A (AISI 304L), rubber quality EPDM) SKD 150-2G-Z/d Seal insert, for swan neck SHD 200 (pressure plates made of stainless steel V2A (AISI 304L), rubber quality EPDM) SKD 200-2G-Z/d Seal insert, for swan neck SHD 300 (pressure plates made of stainless steel V2A (AISI 304L), rubber quality EPDM) SKD 300-2G-Z/d Picture D C E membrane Dichtbahn base plate Grundplatte eXtra insulation Isolierung Z = number of cables d = measured cable diameter Installed SHD 200 before laying of cables 52 Swan neck entry SHD 200 complete with seal insert SKD cablespipesbuildingentries+ 53 Your notes Your notes Your notes Your notes 54 cablespipesbuildingentries+ 55 General terms of business General terms of business I. Scope of Application 1. The following terms and conditions of sale shall apply to all contracts between the buyer and us concerning the delivery of goods. They shall also apply to all future business relations, even if not expressly agreed upon once again. Varying terms and conditions of the buyer which are not expressly recognized by us shall not be binding upon us, even if we do not expressly object to them. Our Terms of Business shall apply even if we carry out the buyer‘s order unconditionally in knowledge of contrary or variant terms and conditions of the buyer. 2. Verbal collateral agreements shall only be binding for us if we have confirmed them in writing. A waiver of the written form requirement needs to be in writing. 3. The guarantee claims of the buyer shall lapse 5 years after delivery of the goods to the buyer if they were used for construction work in accordance with their normal method of utilisation and this has caused their defectiveness, otherwise one year after delivery unless we have maliciously concealed the defect. The following regulations shall apply in this case. Our obligations under section VI number. 4 and section VI number. 5 shall remain unaffected hereby. 4. We shall be obligated in accordance with legal provisions to take back new defective goods or, if appropriate, to reduce the purchase price (reduction) without setting a time limit that would otherwise be required if the buyer‘s customer, as a purchaser of the new sold chattel (purchase of consumable goods), was able to demand that the buyer take back the product or reduce the purchase price due to the defective nature of the product or the buyer is faced with a similar claim under a resultant right of recourse. Furthermore, we are obligated to reimburse any costs, in particular transport, carriage, labour and material costs, which the buyer had to pay in relation to the end user as part of the subsequent performance due to any defect in the product which existed at the time when the risk associated with the goods was passed on by us to the buyer. This claim shall be excluded if the buyer has duly met his duties of inspection and reporting of any defects in accordance with § 377 of the Commercial Code. 5. The obligation in accordance with Section VI Number 4 shall be excluded if the defect is based on advertising statements or other contractual arrangements not originating from us or if the buyer has given the end-consumer a special guarantee. The obligation shall also be excluded if, based on the provisions of law, the buyer himself was not obligated to enforce warranty rights against the end-consumer or had not lodged this objection to a claim asserted against him. This shall also apply if the buyer assumed warranties towards the end-consumer beyond the scope stipulated by law. 6. We accept unlimited liability in accordance with the provisions of law for injury to life, limb or health based on any negligent or intentional breach of duty by us, our legal representatives or vicarious agents as well as for damages covered by the liability in accordance with the Product Liability Act. For damages not covered by Sentence 1 which is based on intentional or grossly negligent breaches of duty or malice on our part or the part of our legal representatives or vicarious agents, we shall be liable in accordance with the provisions of law. In this case, however, the liability for damage compensation shall be limited to typical, foreseeable damage, unless we, our legal representatives or vicarious agents have acted intentionally. To the extent we have issued a guarantee regarding the condition and/or durability of goods or parts, we shall also be liable within the framework of such guarantee. We shall only be liable for damage which is based on the absence of a guaranteed condition or durability but does not directly affect the goods themselves if the risk of such damage was obviously covered by the guarantee of condition or durability. 7. We shall also be liable for damage caused by simple negligence if the negligence relates to the breach of those contractual duties which are particularly important to observe in order to achieve the purpose of the agreement (material duties). We shall only be liable, however, if the damage is typically associated with such contracts and was foreseeable. 8. Any further liability shall be excluded hereby, without regard to the legal nature of the asserted claim; this shall apply in particular to tortious claims or wasted expenditure in lieu of performance; our liability in accordance with Section IV, Paragraphs 2 to 5 of this Agreement shall not be affected hereby. If our liability is excluded or limited, this shall also apply to the personal liability of our employees, collaborators, representatives and vicarious agents. 9. Claims for compensation of the buyer due to defects shall lapse one year after the delivery of the goods. This shall not apply in the event of injury to life, limb or health which is our fault or the fault of our legal representatives or vicious agents, or if we or our legal representatives have acted intentionally or with gross negligence, or if our vicarious agents have acted intentionally. II. Conclusion of Contract 1. We may accept any order from the buyer which can be qualified as an offer to conclude a purchase contract by sending an order confirmation within two weeks or by shipping the ordered products within the same period. 2. Our offers shall be non-binding and subject to change, unless we have expressly designated them as binding. 3. We hereby reserve the title, copyright and all other property rights to all pictures, calculations, drawings and other documents. The buyer may only pass on such pictures, etc. to third parties with our express approval, irrespective of whether such pictures, etc. are identified as confidential or not. III. Terms and Conditions of Payment 1. Our prices are ex works and do not include packaging, unless stipulated otherwise in the order confirmation. Our prices do not include the statutory value added tax. We shall disclose the amount of value added tax applicable on the invoice date separately in our invoice. 2. Cash discounts are not permitted unless otherwise agreed in writing with the customer. The purchase price is payable net (without deduction) immediately upon receipt of the invoice by the buyer if no other payment term is given in the order confirmation. A payment is only deemed to have been made when we are able to dispose of the amount. In the case of cheque payments, payment is only deemed to have been made when the cheque is cleared. 3. If the buyer is in default of payment, the following regulations shall apply. 4. The buyer is only entitled to set-off, even if complaints or counterclaims are being made, if the counterclaims have been determined in a final and legally-binding manner, have been acknowledged by us or are undisputed. The buyer is only authorised to exercise a right of retention if his counter-claim is based on the same contractual relationship. IV. Delivery and Performance Time 1. Delivery dates or periods which have not expressly been agreed as binding are exclusively non-binding information. The delivery period quoted by us only commences when the technical issues have been clarified. Similarly, the buyer is obliged to fulfil all of the obligations properly to which he is subject, and in a timely manner. 2. We are liable in accordance with the statutory provisions if the buyer is able to justify that he has no further interest in fulfilment of the contract as a result of a delay in delivery for which we are responsible. In such case, our liability shall be limited to the foreseeable, typically-occurring damage or loss, if the delivery default is not due to a deliberate breach of contract for which we are responsible, in which a fault on the part of our representatives or vicarious agents is to be ascribed to us. By the same token, we are liable to the buyer in the case of delivery default in accordance with the statutory provisions if this is due to a deliberate breach of contract for which we are responsible, whereby a fault on the part of our representatives or vicarious agents is to be ascribed to us. Our liability shall then be limited to the foreseeable, typically-occurring damage or loss, if the delivery default is only due to grossly negligent violation of the contract for which we are responsible. 3. In the event that a delivery default for which we are responsible is due to a slight breach of a fundamental contractual obligation, whereby a fault on the part of our representatives or vicarious agents is to be ascribed to us, we shall be liable in accordance with the statutory provisions, with the proviso that in such case the compensation liability is limited to the foreseeable, typically occurring damage or loss. 4. A more extensive liability for a delivery default for which we are responsible is hereby excluded. The buyer’s other statutory claims and rights to which he is entitled in addition to the compensation claim due to a delivery default for which we are responsible shall remain unaffected hereby. 5. We are entitled to make partial deliveries and render partial services at any time, provided that this is reasonable for the customer. 6. If the buyer is in default of acceptance, we are then entitled to demand compensation for the loss suffered and any additional expenditure incurred. The same applies if the buyer culpably breaches his obligations to cooperate. Upon the occurrence of default of acceptance or default of debt, the risk of accidental deterioration and accidental destruction shall be transferred to the buyer. V. Transfer of Risk – Dispatch/Packaging 1. Loading and dispatch take place without insurance at the buyer’s risk. We shall endeavour to take into account the dispatch type and the dispatch route wishes and interests of the buyer; additional costs caused thereby - even in the case of agreed freight-free delivery - shall be borne by the buyer. 2. We do not take back transport packaging or any other packaging in accordance with the German Packaging Ordinance; pallets are excluded. The buyer is obliged to take care of the disposal of the packaging at his own cost. 3. If the dispatch is delayed at the request of or due to a fault on the part of the buyer, we shall then store the goods at the buyer’s cost and risk. In this case, the announcement of readiness for dispatch shall be treated as equivalent to the dispatch. 4. Upon the request and at the cost of the buyer, we shall insure the delivery through a transport insurance policy. VI. Guarantee/Liability 1. Buyer‘s claims due to defects only exist if the buyer has duly complied with his inspection and complaint obligations in accordance with § 377 of the German Commercial Code. 2. If a defect in the goods exists for which we are responsible, we are obliged to effect subsequent performance - excluding the rights of the buyer to rescind the contract or to reduce the purchase price (reduction) - unless we are entitled to refuse to effect subsequent performance due to the statutory regulations. The buyer is obliged to give us a reasonable period of time for the subsequent performance. The subsequent performance can, according to the buyer‘s choice, be carried out either by removal of the defect (subsequent improvement) or by delivery of new goods. In the case of the removal of a defect, we shall bear the necessary costs provided that these do not increase because the goods of the contract are at a location other than the place of performance. If the subsequent performance fails, the buyer can, according to his choice, demand reduction in the purchase price (reduction) or can announce his withdrawal from the contract. The subsequent improvement shall be deemed to have failed after the second unsuccessful attempt, unless further attempts to achieve an improvement are appropriate and reasonable for the buyer in view of the nature of the purchased goods. Claims for damages due to a defect relating to the following conditions may only be asserted by the customer if the supplementary performance fails. The right of the buyer to assert a further claim according to the following conditions shall remain unaffected hereby. 56 VII. Retention of Title 1. The delivered goods (reserved goods) shall remain our property until the fulfillment of all claims, including all claims to balances from current accounts, to which we are entitled now or in the future against the buyer. In the event of conduct by the buyer that is in breach of contract, e.g. default in payment, we shall have the right to take the reserved goods back after having previously established a reasonable period of time. If we take the reserved goods back, this shall constitute a rescission of the contract. If we distrain the reserved goods, this shall constitute a rescission of the contract. We shall be entitled to sell the reserved goods after taking them back. After deducting a reasonable amount as selling costs, the sale proceeds shall be credited towards the amounts owed to us by the buyer. 2. The buyer shall be entitled to duly sell and/or use the reserved goods in the course of business, provided the buyer is not in default of payment. Pledging or collateral assignments shall not be permitted. The full scope of any claims concerning the reserved goods (including all claims to balances from current accounts) arising from resale or on any other legal ground (insurance, unlawful act) is hereby assigned by the buyer in advance by way of security to us; we hereby accept such assignment. 3. In the case of third-party access to the goods subject to retention of title, particularly distraints, the buyer will give notice of our ownership and will inform us without undue delay so that we are able to enforce our ownership rights. If the third party is not able to reimburse us for the judicial or extra-judicial costs arising in this connection, the buyer shall then be liable for such costs. VIII. Place of Performance, Jurisdiction, Applicable Law 1. Our registered office shall be the place of performance and jurisdiction for deliveries and payments (including actions due to checks and bills of exchange) and all disputes arising between us and the buyer based on the purchase contracts concluded between us and the buyer. We are also entitled, however, to sue the buyer at his domicile and/or registered office. 2. The relations between the contracting parties shall be determined exclusively in accordance with the law of the Federal Republic of Germany. The application of the Uniform Law on the International Sale of Goods and of the Law on the Formation of Contracts for the International Sale of Goods is hereby excluded. Date October 2006 cablespipesbuildingentries+ 57 Hauff-Technik GmbH & Co. KG Robert-Bosch-Straße 9 89568 Hermaringen, GERMANY 58 Tel. +49 7322 1333-0 Fax +49 7322 1333-999 office@hauff-technik.de www.hauff-technik.de pl_kabel_en_op_140318 The information in this publication represents our current state of technical knowledge and experience. However, given the multitude of possible influences affecting the processing and use of our products, this information does not exempt processors and users from running their own tests and trials. We will replace any parts that cannot be used due to defective materials. We do not replace parts for defects caused due to transport, storage or faulty installation and the consequences thereof. All information without guarantee. Submitted by: