PRODUCTS Anti-condensation coating flexible building. sustainable thinking. PRODUCTS Anti-condensation coating Profiled aluminium Panels with GRAFO-THERM coating for roof and facade structures In certain room climates, roofs or profiled Disadvantages caused by condensate: Aluform AT Anti-condensation coating – aluminium panels without thermal insula- ❚ Corrosion of the steel supporting Provides an effective protection against tion (ventilated roofs) will be subject to structure and fouling of or formation the hazard of condensation depending on of mould on the timber supporting outside temperatures. This condensation structure can be attributed to the fact that the warmer and water vapourcontaining air of the building interior makes contact with ❚ Damages to materials stored and machines ❚ Damages in agriculture when buildings dripping condensate Aluform AT elements are profiled aluminium panels coated with GRAFO-THERM on one side (Table 1). Aluform AT will absorb condensation water the profiled panels and cools down on are used for grain storage and animal and prevent it from dripping. Profiled alu- their cold surface. The conditions found to housing minium panels coated with GRAFO-THERM occur with ventilated roofs may also be encountered on the facades of buildings. ❚ Penetration of moisture into insulating materials ❚ Annoyance to passengers in covered 010 ■ will due to the generous specific surface texture dry at a faster rate than untreated panels. areas, e.g. platform roofs in railway Surfaces coated with Aluform AT are given stations. a bright texture similar to a plaster finish. Aluform AT – multifunctional coating of Aluform panels to absorb condensation water Tab. 1: Condensation water absorption rate to saturation depending on type of coat Description Tab. 2: Versions of colour coats Water absorption capacity g/m2 after 8 hrs at saturation AT 06 370 500 AT 09 504 675 Outside Inside colour coatings: Polyester or PVdF grey GRAFO THERM without colours: grey stucco-mill finish or smooth-mill finish GRAFO-THERM Aluform AT is more than just a Use of Aluform AT panels Storage of Aluform AT panels protection against condensation water. Aluform panels can be universally used The Aluform AT panels should be stored at for roofs and walls witch are subject to a roofed place. ❚ Fire protection: condensation according to the time of the building material class A 2 according day, e.g. Range of Aluform AT panels offered to DIN 4102 ❚ sheds without thermal insulation Trapezoidal and sinusoidal panels are ❚ double-layer ventilated thermal roofs as offered in two GRAFO-THERM standard ❚ Noise protection, noise absorption: Profiled panels with AT coating can ab- weather protection coats (Table 1). The available lengths are sorb noise at a rate of 5 – 30% depending ❚ agricultural buildings on the thickness of the coat and the fre- ❚ indoor swimming pools, sports halls quency of the sound waves encountered ❚ platform roofs The colours of the coats can be seen and can thus reduce the noise level in the ❚ canopies in Table 2. In addition to the standard building inside. ❚ grandstands program, other dimensions, coats or ❚ garages colours can be supplied on request. effect in case of hail-storm, heavy rainfall Aluform AT will not replace neither an Connecting elements, sealing materials or wind. Loss factor, d komb ≈ 0,02 adequate thermal insulation layer nor an and bent flashings are available for the appropriate ventilation of the bottom or installation of the panels. Flashings that back sides. are exposed to the inside and outside ❚ Noise insulation: from 2m to 20m. The AT coating will provide a deadening ❚ Thermal protection: AT coating will give a heat-insulating effect that reduces the condensation rate; thermal conductance 0.085 W/mK. ❚ Corrosion protection: climate of a building are possible to be Installation of Aluform AT panels Great care should be taken not to damage Indirect effect by preventing condensate the coated aluminium panels during instal- from dripping on the supporting lation. Especially, the panels should not be structure. in contact with the purlins when pushing them in place. Possible damages to the coat may be repaired by means of a brush. A drying time of approx. 8 hours must be allowed when dried in the open air (at about 20 °C). Make sure to install the panels in the specified direction. coated with GRAFO-THERM on one side. Phone: +49 (0) 35723 99-0 Dresdener Straße 15 Fax: D-02994 Bernsdorf Email: info@aluform.de © www.mkwa.de Aluform System GmbH & Co. KG +49 (0) 35723 99-401 www.aluform.de ❚ Overlapping lengths for cross joints Ordering/description of Aluform AT profiled panels ❚ Desired texture and paint coat of outside (Instruction of Installation, Info No. 713) surface of profiled panels (Table 2) ❚ Position for longitudinal joints and eaves ❚ Type of GRAFO-THERM coat for inside The following must be stated for ordering: side depending on direction of installa ❚ Required quantity, type of profile and tion according to Figure 1 for roofs and dimensions of profiled aluminium panels ❚ Fitting position of profiled panels surface (Table 1) ❚ Required fitting elements; description Figure 2 for walls. The maximum of the area to be coated in the case of possible dimension ´a´ of the non-coated bent flashings (sketch) (positive = P, negative = N) and side end faces is 300 mm. The visible side to be coated with GRAFOTHERM should be protected against spray dust by protective film. Ordering example: Description: Trapezoidal aluminium profile 45/150 Aluform 45/150 - 0.7 - AT 06 Metal thickness t = 0.7 mm outside, stucco-mill finish, P AT (anti-condensation) coating inside, AT grey, N Positive side: Outside, stucco-mill finish Negative side: Inside, grey AT 06 Figure 1: Figure 2: GRAFO-THERM coating of Aluform trapezoidal profile 45/150, GRAFO-THERM coating of Aluform trapezoidal profile 45/150, negative side. Installed as roof profile. The joint and eaves areas positive side. Installed as wall profile. The joint and plinth areas are not coated. are not coated. Installation from left to right Installation from right to left Installation from right to left Longitudinal joint area (short extended side lap) Installation from left to right Longitudinal joint area (short extended side lap) positive side = painted side a a End face without AT coating Long extended side lap without AT coating negative side with AT coating End face without AT coating Long extended side lap without AT coating a a Cross joint or plinth area 010 ■ Cross joint or plinth area