lindab | access doors Access doors Lindab 1 General information and theory 2 Safe 3 Silencers 4 Dampers & Measure units 5 Fire dampers & Smoke evacuation 6 Air valves 7 Roof hoods 8 Other circular products 9 Transfer 10 Rectangular 11 Flexible ducting 12 Isol 13 Access doors 14 Smart tools 15 Duct suspensions & Support systems 16 Fastening material 17 Index 18 lindab | access doors Content – Access doors LKCR ............................................661 1 EPFH............................................ 647 IPRD .............................................662 RD.................................................656 2 ESHU ........................................... 648 3 IPL ................................................663 4 KCRU ........................................... 649 5 TLU .............................................. 650 6 7 Duct shape Placing KCU ............................................. 651 Uninsulated 8 9 Circular Duct end Duct wall EPFH IPLR ESHU PTL KCRU TLU KCU EKTL KCIVU .......................................... 652 Insulated KCIVU EPFUI 10 EPFUI ........................................... 653 11 12 IPLR ............................................. 654 13 PTL............................................... 657 14 15 EKTL ............................................ 658 16 17 IPF................................................ 660 18 646 We reserve the right to make changes without prior notice Rectangular Duct wall LKCR IPF LKCR IPRD RD IPL lindab | access doors Access door EPFH Dimensions Ø80 1 30 2 Ød Ød l Ø100–160 l 5 3 4 Ø400–630 l 30 Ø200–315 l 30 5 Description 6 Access door, which fits outside a Safe fitting. 7 Ød Ød Some dimensions Ø80–355 have notches for bayonet locking, in order to be better fixed in ducts with positive pressure. You must then add two rivets to the fitting. Dimensions Ø400–630 have eccentric locks in order to be better fixed in ducts with positive pressure. You must then mount the hooks of the locks in the fitting. 8 No Click function – no notches. Can achieve maximum tightness class D. Ordering example EPFH Product Dimension Ød 250 Ød nom 80 100 112 125 140 150 160 180 200 224 250 280 300 315 355 400 450 500 560 600 630 l mm 48 40 40 40 40 40 40 40 40 60 60 60 60 60 60 80 80 80 80 80 80 m kg 0,09 0,15 0,16 0,17 0,19 0,21 0,22 0,24 0,32 0,38 0,55 0,64 0,69 0,74 0,87 1,26 1,57 1,87 2,18 2,49 2,71 Handle Lock 1 fixed small 1 folding 1 folding 1 folding 1 folding 1 folding 1 folding 1 fixed 1 fixed 1 fixed 2 fixed 2 fixed 2 fixed 2 fixed 2 fixed 2 fixed 2 fixed 2 fixed 2 fixed 2 fixed 2 fixed – bayonet – bayonet – – bayonet – bayonet – bayonet – – bayonet – eccenter eccenter eccenter eccenter eccenter eccenter 9 10 11 12 13 14 15 16 17 18 We reserve the right to make changes without prior notice 647 lindab | access doors Access door ESHU Dimensions 1 Ø100–160 Ø200–630 l 30 2 l 5 4 Ød1 Ød1 3 5 6 Description Access door, which fits inside an SR duct. 7 No Click function – has a closed turned-over end. Can achieve maximum tightness class D. 8 9 10 11 12 Ød1 nom 100 112 125 140 150 160 180 200 224 250 280 300 315 355 400 500 630 l mm 10 4 10 10 10 10 10 10 10 10 4 10 10 10 12 12 4 13 14 15 16 Ordering example 17 Product Dimension Ød1 ESHU 160 18 648 We reserve the right to make changes without prior notice m kg 0,17 0,18 0,19 0,17 0,22 0,29 0,32 0,36 0,44 0,58 0,70 0,78 0,88 0,99 1,34 1,72 2,62 Handle 1 folding 1 folding 1 folding 1 folding 1 folding 1 folding 1 fixed 1 fixed 1 fixed 2 fixed 2 fixed 2 fixed 2 fixed 2 fixed 2 fixed 2 fixed 2 fixed lindab | access doors Access door KCRU Dimensions 1 2 Ød1 3 4 l 5 Description Access door which complies with the requirements for access doors in Swedish Standard SS 2645. The door is held in place by a tension strap with adjustable eccentric lock. This offers a quick and simple opening and closing. A built-in handle also aids handling. Ød1 nom 100 125 160 200 250 315 400 l mm 480 480 480 480 480 480 480 6 m kg 1,06 1,30 1,80 2,00 2,92 4,10 5,51 7 8 9 10 11 12 13 14 15 16 Ordering example KCRU 250 Product Dimension Ød1 17 18 We reserve the right to make changes without prior notice 649 lindab | access doors Access door TLU Dimensions 1 2 B b* a* Ød1 3 4 l 5 6 Description Locked with hexagon bolts. Can achieve maximum tightness class C. 7 8 9 Ød1 nom 80 100 125 160 200 250 315 l mm 307 307 307 307 307 382 452 a* mm 187 187 187 187 187 232 304 *Note! Opening dimensions. 10 11 12 13 14 15 16 Ordering example 17 Product Dimension Ød1 TLU 125 18 650 We reserve the right to make changes without prior notice b* mm 80 100 125 160 200 250 315 B mm 140 160 185 220 260 310 375 m kg 0,59 0,68 0,80 1,00 1,38 2,00 2,80 lindab | access doors Access door KCU Dimensions 1 Δp Pa 3400 3400 3400 3400 3400 2600 10000 10000 10000 Ød nom 100 125 160 200 250 315 400 500 630 l mm 40 40 40 40 60 60 90 90 90 m kg 0,30 0,40 0,60 0,80 1,28 1,81 2,82 6,40 10,1 Handle 1 folding 1 folding 1 folding 1 fixed 2 fixed 2 fixed 2 fixed 2 fixed 2 fixed 2 3 4 5 Fire classification (Swedish type approval) The access door has been tested and has a swedish type approval for the following fire classification: Description 6 Insulated access door which fits outside a Safe fitting. Ø100–315 The door in is held in place by spring clips against the inside of the Safe fitting. The door is loosened by pulling it while turning it slightly, and is installed in the opposite manner. There are one or two handles to help in the process. Ø400–630 The door is held in place by two eccentric locks and is loosened by unlocking the eccentric locks. Slightly turning and pulling the door will make it easier to get it loose. Δp in the table gives the maximum positive pressure the access door can withstand when installed from beneath. Ød nom 100–400 500–630 In order to use the access door’s alternative fire classes: - minimum safety distance according to table below must be ensured - the surface of the access door must not be changed, e.g. by painting 9 10 Safety distance at radiation intensity Can achieve maximum tightness class D. Dimensions Ø400 – 630 Ød Ø200 – 315 Ød Ød 8 Alternative fire classification with safety distances, guidance for planning. No Click function – no notches. Ø100 – 160 7 Fire classification E 60 None Ød nom Fire classification alternative 3 kW/m² (evacuating people) mm 10 kW/m² (interior mtrl) (inflammable mtrl) mm 30 kW/m² (building mtrl) (wood) mm 100 125 160 200 250 315 400 500 630 EI 60 EI 60 EI 60 EI 60 EI 60 EI 60 EI 60 None None 50 50 50 50 50 50 50 - 10 10 10 10 10 10 10 - 10 10 10 10 10 10 10 - 11 12 13 14 15 16 l 5 l 30 Ordering example l KCU 30 Product Dimension Ød We reserve the right to make changes without prior notice 250 17 18 651 lindab | access doors Access door KCIVU Dimensions 1 Ø200 Ø100–160 l 2 l 30 5 Ød Ød 3 4 5 Ø250–315 6 Ø400 l Description l 30 30 8 9 10 Ø100–315 The door in is held in place by spring clips against the inside of the Safe fitting. The door is loosened by pulling it while turning it slightly, and is installed in the opposite manner. There are one or two handles to help in the process. Ø400 The door is held in place by two eccentric locks and is loosened by unlocking the eccentric locks. Slightly turning and pulling the door will make it easier to get it loose. Δp in the table gives the maximum positive pressure the access door can withstand when installed from beneath. No Click function – no notches. 11 Ød 7 Ød Insulated access door which fits outside a Safe fitting. Ød nom 100 125 160 200 250 315 400 Can achieve maximum tightness class D. 12 13 Δp Pa 3400 3400 3400 3400 3400 2600 10000 l mm 50 50 50 50 70 70 100 m kg 0,43 0,62 1,00 1,41 2,25 3,30 5,00 Handle 1 folding 1 folding 1 folding 1 fixed 2 fixed 2 fixed 2 fixed 14 Fire classification (Swedish type approval) The access door has been tested and has a swedish type approval for the following fire classification: 15 16 Ordering example KCIVU 17 250 Ød nom 100–400 Product Dimension Ød 18 652 We reserve the right to make changes without prior notice Fire classification EI 60 lindab | isol Access door EPFUI Dimensions 1 l 2 Ød 3 4 5 Description 6 25 mm insulation. End cap which fits outside a fitting. Belongs to the Isol programme range. Can achieve maximum tightness class D. Ød nom 100 125 150 160 200 250 300 315 355 400 450 500 l mm 70 70 70 70 70 90 90 90 90 110 110 110 m kg 0,50 0,60 0,75 0,83 1,03 1,71 2,16 2,29 3,00 3,81 4,30 5,40 7 8 9 10 11 50 mm insulation. Ød nom 100 125 150 160 200 250 300 315 355 400 450 500 Ordering example EPFUI 250 l mm 90 90 90 90 90 110 110 110 110 130 130 130 m kg 0,73 0,88 1,06 1,13 1,41 2,24 2,90 2,94 3,80 4,71 5,30 6,55 12 13 14 15 16 25 Product Dimension Ød Insulation 25/50 17 18 We reserve the right to make changes without prior notice 653 lindab | access doors Access door IPLR Dimensions 1 Ød 2 3 4 6 a* 5 Description Access door, which fits on the curved side of a circular duct. 7 A neoprene cellular gasket seals on the duct's inside. Supplied with a self adhesive template which guides when cutting the oval aperture. Ø 100–800 is available in stainless steel by request. 8 Can achieve maximum tightness class C. 9 Specification Door Panels 10 Locking Knob Bolts/Nuts Gasket 11 12 Corrosion resistant galvanised mild steel. Polyamid. Zinc plated mild steel. Neoprene cellular gasket which will not support combustion in its installed state. Alternative materials Door panels are available in aluminium to special order. 13 14 15 16 Ordering exaple 17 Product Dimension Ød Material IPLR 500 GALV b* GALV Ød nom 80 100–125 150–160 180 200 250 300–315 355 400 450 a* mm 180 180 250 250 250 250 250 250 400 400 b* mm 80 80 150 150 150 150 150 150 300 300 m kg 0,36 0,36 0,80 0,80 0,80 0,80 0,80 0,80 2,20 2,20 500 560 630 710 800 900 1000 1120 1250 400 400 400 400 400 400 500 500 500 300 300 300 300 300 300 400 400 400 2,20 2,20 2,20 2,20 2,20 2,31 2,31 2,31 2,31 * Note! Opening dimensions. 18 654 We reserve the right to make changes without prior notice lindab | access doors Access door IPLR Dimensions 1 Stainless steel Ød nom a mm b mm m kg 80 100 125 160 200 250 315 355 400 450 500 560 630 710 800 900 180 180 180 200 200 200 300 300 400 400 400 400 400 400 400 400 80 80 80 100 100 100 200 200 300 300 300 300 300 300 300 300 0,32 0,32 0,32 0,41 0,41 0,41 1,01 1,01 2,11 2,11 2,11 2,11 2,11 2,11 2,11 2,11 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 We reserve the right to make changes without prior notice 655 lindab | access doors Accesss door RD Dimensions 1 2 b 3 4 5 a 6 Description 7 Access door, which fits on the flat side of a rectangular duct. Consists of a door and a frame. The door has a 25 mm thick high density insulation. The frame is attached to the duct wall by means of fixing tabs. Both door and frame are supplied with a rubber gasket. 8 Can achieve maximum tightness class C. Type RD31 RD44 RD50 9 10 11 12 13 14 15 16 Ordering example 17 18 656 RD44 Product Largest side Smallest side 400 300 a b We reserve the right to make changes without prior notice a mm 300 400 500 b mm 150 300 500 m kg 1,47 2,46 4,30 lindab | access doors Access door PTL Dimensions Ød 1 2 a* 3 4 5 Description Access door for circular duct. Ø 100–400 delivered with sticker for easy installation. Locked with hexagon bolts. Can achieve maximum tightness class C. 6 b* Ød nom 100 a* mm 200 b* mm 100 m kg 0,60 7 125 160 200 250 315 400 500 630 800 1000 200 200 200 200 200 200 250 250 500 500 100 100 200 200 200 200 250 250 400 400 0,60 0,60 0,70 0,70 0,70 0,70 1,00 1,00 2,40 2,40 8 * Note! Opening dimensions. 9 10 11 12 13 14 15 16 Ordering example PTL 125 Product Dimension Ød 17 18 We reserve the right to make changes without prior notice 657 lindab | access doors Access door EKTL Dimensions H 1 Ød 2 3 a* 4 5 6 Description Access door for insulated circular duct. Locked with hexagon bolts. 7 b* Can achieve maximum tightness class C. 8 9 10 11 12 13 14 15 16 Ordering example 17 18 658 EKTL Product code Dimension Ød Insulation strength H 125 60 Ød nom H mm a* mm b* mm m kg 100 50 200 100 0,95 100 60 200 100 1,00 100 80 200 100 1,30 100 100 200 100 1,55 125 50 200 100 0,95 125 60 200 100 1,00 125 80 200 100 1,30 125 100 200 100 1,55 160 50 200 100 0,95 160 60 200 100 1,00 160 80 200 100 1,30 160 100 200 100 1,55 200 50 200 200 2,40 200 60 200 200 2,50 200 80 200 200 2,75 200 100 200 200 3,00 250 50 200 200 2,40 250 60 200 200 2,50 250 80 200 200 2,75 250 100 200 200 3,00 315 50 200 200 2,40 315 60 200 200 2,50 315 80 200 200 2,75 315 100 200 200 3,00 400 50 200 200 2,40 400 60 200 200 2,50 400 80 200 200 2,75 400 100 200 200 3,00 We reserve the right to make changes without prior notice lindab | access doors Access door EKTL Ød nom H mm a* mm b* mm m kg 500 50 200 200 5,40 500 60 500 400 5,70 500 80 500 400 6,40 500 100 500 400 7,00 630 50 500 400 5,40 630 60 500 400 5,70 630 80 500 400 6,40 630 100 500 400 7,00 800 50 500 400 5,40 800 60 500 400 5,70 800 80 500 400 6,40 800 100 500 400 7,00 1000 50 500 400 5,40 1000 60 500 400 5,70 1000 80 500 400 6,40 1000 100 500 400 7,00 1250 50 500 400 5,40 1250 60 500 400 5,70 1250 80 500 400 6,40 1250 100 500 400 7,00 1 2 3 4 5 6 7 8 * Note! Opening dimensions. 9 10 11 12 13 14 15 16 17 18 We reserve the right to make changes without prior notice 659 lindab | access doors Access door IPF Dimensions 1 2 b 3 4 5 a 6 Description 7 Access door, which fits on the flat side of a rectangular duct. A neoprene cellular gasket seals on the duct's inside. Supplied with a self adhesive template which guides when cutting the rectangular aperture. Can achieve maximum tightness class C. 8 9 a* mm 180 200 250 300 400 500 600 b* mm 80 100 150 200 300 400 450 m kg 0,16 0,33 0,65 1,10 2,10 4,10 4,90 * Note! Opening dimensions. 10 11 12 13 14 15 16 Ordering example 17 Product Largest side Smallest side IPF 250 150 a b 18 660 We reserve the right to make changes without prior notice lindab | access doors Access door LKCR Dimensions 45 b 1 2 a 3 45 1 80 4 Non-insulated duct 5 The access door is also used as an inspection hatch for rectangular ducts. To the access door belongs a fixing frame, which is attached to the rectangular duct. This is normally done with blind rivets through the folded-down edge of the done frame. It can also be provided with folding tabs on request. It is easy to remove the access door from the fixing frame by using over-centre catches. In the insulated versions, the inner side will always be in level with the innermost boundary line of the duct, irrespective of whether the duct is insulated internally or externally. The table below shows the insulation thickness of the door at different duct insulation alternatives. 2 6 80 Description 7 Internally insulated duct 8 3 9 Externally insulated duct Can achieve maximum tightness class C. The door should not be placed closer than 50 mm from the nearest side of the rectangular duct. Maximum square measurement of the access door is 1170×1170 mm. 10 11 12 Ordering example LKCR 500 300 2 50/100 Product Largest side a Smallest side b Non-insulated duct Type 1 Internally insulated duct Type 2 Externally insulated duct Type 3 Duct/cover insulation 30/80 mm (Type 2) Duct/cover insulation 50/100 mm (Type 2) Duct/cover insulation 70/120 mm (Type 2) Duct/cover insulation 100/150 mm (Type 2) Duct/cover insulation 120/170 mm (Type 2) Duct/cover insulation 40/60 mm (Type 3) Duct/cover insulation 50/80 mm (Type 3) Duct/cover insulation 70/100 mm (Type 3) Duct/cover insulation 140/160 mm (Type 3) 13 14 15 16 17 18 We reserve the right to make changes without prior notice 661 lindab | access doors Access door IPRD Dimensions 1 2 b 3 4 5 a 6 Description 7 Access door, which fits on the flat side of a rectangular duct. Consists of a door and a frame. The door has a 25 mm thick high density insulation. The frame is attached to the duct wall by means of fixing tabs. Both door and frame are supplied with a rubber gasket. 8 Can achieve maximum tightness class C. a mm 300 400 500 9 10 11 12 13 14 15 16 Ordering example 17 Product Largest side Smallest side IPRD 400 300 a b 18 662 We reserve the right to make changes without prior notice b mm 150 300 500 m kg 1,47 2,46 4,30 lindab | access doors Access door IPL Dimensions 1 2 b 3 4 5 a Description Access door, which fits on the flat side of a rectangular duct. Consists of a door and a frame. The door has a 20 mm thick high density insulation. The frame is attached to the duct wall by means of screws. A gasket as well as a retaining chain is fitted between door and frame. Can achieve maximum tightness class C. Size nom 300 × 150 460 × 250 530 × 360 635 × 430 a mm 349 502 578 679 b mm 197 298 400 476 6 m kg 1,03 2,08 2,70 3,57 7 8 9 10 11 12 13 14 15 16 Ordering example IPL 460 250 Product Size nom 17 18 We reserve the right to make changes without prior notice 663