Access doors

advertisement
lindab | access doors
Access doors
Lindab
1
General information and theory
2
Safe
3
Silencers
4
Dampers & Measure units
5
Fire dampers & Smoke
evacuation
6
Air valves
7
Roof hoods
8
Other circular products
9
Transfer
10
Rectangular
11
Flexible ducting
12
Isol
13
Access doors
14
Smart tools
15
Duct suspensions & Support
systems
16
Fastening material
17
Index
18
lindab | access doors
Content – Access doors
LKCR ............................................661
1
EPFH............................................ 647
IPRD .............................................662
RD.................................................656
2
ESHU ........................................... 648
3
IPL ................................................663
4
KCRU ........................................... 649
5
TLU .............................................. 650
6
7
Duct shape
Placing
KCU ............................................. 651
Uninsulated
8
9
Circular
Duct end
Duct wall
EPFH
IPLR
ESHU
PTL
KCRU
TLU
KCU
EKTL
KCIVU .......................................... 652
Insulated
KCIVU
EPFUI
10
EPFUI ........................................... 653
11
12
IPLR ............................................. 654
13
PTL............................................... 657
14
15
EKTL ............................................ 658
16
17
IPF................................................ 660
18
646
We reserve the right to make changes without prior notice
Rectangular
Duct wall
LKCR
IPF
LKCR
IPRD
RD
IPL
lindab | access doors
Access door
EPFH
Dimensions
Ø80
1
30
2
Ød
Ød
l
Ø100–160
l
5
3
4
Ø400–630
l 30
Ø200–315
l
30
5
Description
6
Access door, which fits outside a Safe fitting.
7
Ød
Ød
Some dimensions Ø80–355 have notches for bayonet locking, in order to be better fixed in ducts with positive pressure. You must then add two rivets to the fitting.
Dimensions Ø400–630 have eccentric locks in order to be
better fixed in ducts with positive pressure. You must then
mount the hooks of the locks in the fitting.
8
No Click function – no notches.
Can achieve maximum tightness class D.
Ordering example
EPFH
Product
Dimension Ød
250
Ød
nom
80
100
112
125
140
150
160
180
200
224
250
280
300
315
355
400
450
500
560
600
630
l
mm
48
40
40
40
40
40
40
40
40
60
60
60
60
60
60
80
80
80
80
80
80
m
kg
0,09
0,15
0,16
0,17
0,19
0,21
0,22
0,24
0,32
0,38
0,55
0,64
0,69
0,74
0,87
1,26
1,57
1,87
2,18
2,49
2,71
Handle
Lock
1 fixed small
1 folding
1 folding
1 folding
1 folding
1 folding
1 folding
1 fixed
1 fixed
1 fixed
2 fixed
2 fixed
2 fixed
2 fixed
2 fixed
2 fixed
2 fixed
2 fixed
2 fixed
2 fixed
2 fixed
–
bayonet
–
bayonet
–
–
bayonet
–
bayonet
–
bayonet
–
–
bayonet
–
eccenter
eccenter
eccenter
eccenter
eccenter
eccenter
9
10
11
12
13
14
15
16
17
18
We reserve the right to make changes without prior notice
647
lindab | access doors
Access door
ESHU
Dimensions
1
Ø100–160
Ø200–630
l
30
2
l
5
4
Ød1
Ød1
3
5
6
Description
Access door, which fits inside an SR duct.
7
No Click function – has a closed turned-over end.
Can achieve maximum tightness class D.
8
9
10
11
12
Ød1
nom
100
112
125
140
150
160
180
200
224
250
280
300
315
355
400
500
630
l
mm
10
4
10
10
10
10
10
10
10
10
4
10
10
10
12
12
4
13
14
15
16
Ordering example
17
Product
Dimension Ød1
ESHU
160
18
648
We reserve the right to make changes without prior notice
m
kg
0,17
0,18
0,19
0,17
0,22
0,29
0,32
0,36
0,44
0,58
0,70
0,78
0,88
0,99
1,34
1,72
2,62
Handle
1 folding
1 folding
1 folding
1 folding
1 folding
1 folding
1 fixed
1 fixed
1 fixed
2 fixed
2 fixed
2 fixed
2 fixed
2 fixed
2 fixed
2 fixed
2 fixed
lindab | access doors
Access door
KCRU
Dimensions
1
2
Ød1
3
4
l
5
Description
Access door which complies with the requirements for
access doors in Swedish Standard SS 2645.
The door is held in place by a tension strap with adjustable
eccentric lock. This offers a quick and simple opening and
closing. A built-in handle also aids handling.
Ød1
nom
100
125
160
200
250
315
400
l
mm
480
480
480
480
480
480
480
6
m
kg
1,06
1,30
1,80
2,00
2,92
4,10
5,51
7
8
9
10
11
12
13
14
15
16
Ordering example
KCRU
250
Product
Dimension Ød1
17
18
We reserve the right to make changes without prior notice
649
lindab | access doors
Access door
TLU
Dimensions
1
2
B
b*
a*
Ød1
3
4
l
5
6
Description
Locked with hexagon bolts.
Can achieve maximum tightness class C.
7
8
9
Ød1
nom
80
100
125
160
200
250
315
l
mm
307
307
307
307
307
382
452
a*
mm
187
187
187
187
187
232
304
*Note! Opening dimensions.
10
11
12
13
14
15
16
Ordering example
17
Product
Dimension Ød1
TLU
125
18
650
We reserve the right to make changes without prior notice
b*
mm
80
100
125
160
200
250
315
B
mm
140
160
185
220
260
310
375
m
kg
0,59
0,68
0,80
1,00
1,38
2,00
2,80
lindab | access doors
Access door
KCU
Dimensions
1
Δp
Pa
3400
3400
3400
3400
3400
2600
10000
10000
10000
Ød
nom
100
125
160
200
250
315
400
500
630
l
mm
40
40
40
40
60
60
90
90
90
m
kg
0,30
0,40
0,60
0,80
1,28
1,81
2,82
6,40
10,1
Handle
1 folding
1 folding
1 folding
1 fixed
2 fixed
2 fixed
2 fixed
2 fixed
2 fixed
2
3
4
5
Fire classification (Swedish type approval)
The access door has been tested and has a swedish type
approval for the following fire classification:
Description
6
Insulated access door which fits outside a Safe fitting.
Ø100–315
The door in is held in place by spring clips against the inside
of the Safe fitting. The door is loosened by pulling it while
turning it slightly, and is installed in the opposite manner.
There are one or two handles to help in the process.
Ø400–630
The door is held in place by two eccentric locks and is loosened by unlocking the eccentric locks. Slightly turning and
pulling the door will make it easier to get it loose.
Δp in the table gives the maximum positive pressure the
access door can withstand when installed from beneath.
Ød
nom
100–400
500–630
In order to use the access door’s alternative fire classes:
- minimum safety distance according to table below
must be ensured
- the surface of the access door must not be changed,
e.g. by painting
9
10
Safety distance at radiation intensity
Can achieve maximum tightness class D.
Dimensions
Ø400 – 630
Ød
Ø200 – 315
Ød
Ød
8
Alternative fire classification with safety distances, guidance for planning.
No Click function – no notches.
Ø100 – 160
7
Fire classification
E 60
None
Ød
nom
Fire
classification
alternative
3 kW/m²
(evacuating
people)
mm
10 kW/m²
(interior mtrl)
(inflammable
mtrl)
mm
30 kW/m²
(building mtrl)
(wood)
mm
100
125
160
200
250
315
400
500
630
EI 60
EI 60
EI 60
EI 60
EI 60
EI 60
EI 60
None
None
50
50
50
50
50
50
50
-
10
10
10
10
10
10
10
-
10
10
10
10
10
10
10
-
11
12
13
14
15
16
l
5
l
30
Ordering example
l
KCU
30
Product
Dimension Ød
We reserve the right to make changes without prior notice
250
17
18
651
lindab | access doors
Access door
KCIVU
Dimensions
1
Ø200
Ø100–160
l
2
l
30
5
Ød
Ød
3
4
5
Ø250–315
6
Ø400
l
Description
l
30
30
8
9
10
Ø100–315
The door in is held in place by spring clips against the inside
of the Safe fitting. The door is loosened by pulling it while
turning it slightly, and is installed in the opposite manner.
There are one or two handles to help in the process.
Ø400
The door is held in place by two eccentric locks and is loosened by unlocking the eccentric locks. Slightly turning and
pulling the door will make it easier to get it loose.
Δp in the table gives the maximum positive pressure the
access door can withstand when installed from beneath.
No Click function – no notches.
11
Ød
7
Ød
Insulated access door which fits outside a Safe fitting.
Ød
nom
100
125
160
200
250
315
400
Can achieve maximum tightness class D.
12
13
Δp
Pa
3400
3400
3400
3400
3400
2600
10000
l
mm
50
50
50
50
70
70
100
m
kg
0,43
0,62
1,00
1,41
2,25
3,30
5,00
Handle
1 folding
1 folding
1 folding
1 fixed
2 fixed
2 fixed
2 fixed
14
Fire classification (Swedish type approval)
The access door has been tested and has a swedish type
approval for the following fire classification:
15
16
Ordering example
KCIVU
17
250
Ød
nom
100–400
Product
Dimension Ød
18
652
We reserve the right to make changes without prior notice
Fire classification
EI 60
lindab | isol
Access door
EPFUI
Dimensions
1
l
2
Ød
3
4
5
Description
6
25 mm insulation.
End cap which fits outside a fitting.
Belongs to the Isol programme range.
Can achieve maximum tightness class D.
Ød
nom
100
125
150
160
200
250
300
315
355
400
450
500
l
mm
70
70
70
70
70
90
90
90
90
110
110
110
m
kg
0,50
0,60
0,75
0,83
1,03
1,71
2,16
2,29
3,00
3,81
4,30
5,40
7
8
9
10
11
50 mm insulation.
Ød
nom
100
125
150
160
200
250
300
315
355
400
450
500
Ordering example
EPFUI
250
l
mm
90
90
90
90
90
110
110
110
110
130
130
130
m
kg
0,73
0,88
1,06
1,13
1,41
2,24
2,90
2,94
3,80
4,71
5,30
6,55
12
13
14
15
16
25
Product
Dimension Ød
Insulation 25/50
17
18
We reserve the right to make changes without prior notice
653
lindab | access doors
Access door
IPLR
Dimensions
1
Ød
2
3
4
6
a*
5
Description
Access door, which fits on the curved side of a circular duct.
7
A neoprene cellular gasket seals on the duct's inside.
Supplied with a self adhesive template which guides when
cutting the oval aperture.
Ø 100–800 is available in stainless steel by request.
8
Can achieve maximum tightness class C.
9
Specification
Door Panels
10
Locking Knob
Bolts/Nuts
Gasket
11
12
Corrosion resistant galvanised mild
steel.
Polyamid.
Zinc plated mild steel.
Neoprene cellular gasket which will not
support combustion in its installed
state.
Alternative materials
Door panels are available in aluminium to special order.
13
14
15
16
Ordering exaple
17
Product
Dimension Ød
Material
IPLR
500
GALV
b*
GALV
Ød
nom
80
100–125
150–160
180
200
250
300–315
355
400
450
a*
mm
180
180
250
250
250
250
250
250
400
400
b*
mm
80
80
150
150
150
150
150
150
300
300
m
kg
0,36
0,36
0,80
0,80
0,80
0,80
0,80
0,80
2,20
2,20
500
560
630
710
800
900
1000
1120
1250
400
400
400
400
400
400
500
500
500
300
300
300
300
300
300
400
400
400
2,20
2,20
2,20
2,20
2,20
2,31
2,31
2,31
2,31
* Note! Opening dimensions.
18
654
We reserve the right to make changes without prior notice
lindab | access doors
Access door
IPLR
Dimensions
1
Stainless steel
Ød
nom
a
mm
b
mm
m
kg
80
100
125
160
200
250
315
355
400
450
500
560
630
710
800
900
180
180
180
200
200
200
300
300
400
400
400
400
400
400
400
400
80
80
80
100
100
100
200
200
300
300
300
300
300
300
300
300
0,32
0,32
0,32
0,41
0,41
0,41
1,01
1,01
2,11
2,11
2,11
2,11
2,11
2,11
2,11
2,11
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
We reserve the right to make changes without prior notice
655
lindab | access doors
Accesss door
RD
Dimensions
1
2
b
3
4
5
a
6
Description
7
Access door, which fits on the flat side of a rectangular duct.
Consists of a door and a frame. The door has a 25 mm thick
high density insulation. The frame is attached to the duct
wall by means of fixing tabs. Both door and frame are supplied with a rubber gasket.
8
Can achieve maximum tightness class C.
Type
RD31
RD44
RD50
9
10
11
12
13
14
15
16
Ordering example
17
18
656
RD44
Product
Largest side
Smallest side
400
300
a
b
We reserve the right to make changes without prior notice
a
mm
300
400
500
b
mm
150
300
500
m
kg
1,47
2,46
4,30
lindab | access doors
Access door
PTL
Dimensions
Ød
1
2
a*
3
4
5
Description
Access door for circular duct.
Ø 100–400 delivered with sticker for easy installation.
Locked with hexagon bolts.
Can achieve maximum tightness class C.
6
b*
Ød
nom
100
a*
mm
200
b*
mm
100
m
kg
0,60
7
125
160
200
250
315
400
500
630
800
1000
200
200
200
200
200
200
250
250
500
500
100
100
200
200
200
200
250
250
400
400
0,60
0,60
0,70
0,70
0,70
0,70
1,00
1,00
2,40
2,40
8
* Note! Opening dimensions.
9
10
11
12
13
14
15
16
Ordering example
PTL
125
Product
Dimension Ød
17
18
We reserve the right to make changes without prior notice
657
lindab | access doors
Access door
EKTL
Dimensions
H
1
Ød
2
3
a*
4
5
6
Description
Access door for insulated circular duct.
Locked with hexagon bolts.
7
b*
Can achieve maximum tightness class C.
8
9
10
11
12
13
14
15
16
Ordering example
17
18
658
EKTL
Product code
Dimension Ød
Insulation strength H
125
60
Ød
nom
H
mm
a*
mm
b*
mm
m
kg
100
50
200
100
0,95
100
60
200
100
1,00
100
80
200
100
1,30
100
100
200
100
1,55
125
50
200
100
0,95
125
60
200
100
1,00
125
80
200
100
1,30
125
100
200
100
1,55
160
50
200
100
0,95
160
60
200
100
1,00
160
80
200
100
1,30
160
100
200
100
1,55
200
50
200
200
2,40
200
60
200
200
2,50
200
80
200
200
2,75
200
100
200
200
3,00
250
50
200
200
2,40
250
60
200
200
2,50
250
80
200
200
2,75
250
100
200
200
3,00
315
50
200
200
2,40
315
60
200
200
2,50
315
80
200
200
2,75
315
100
200
200
3,00
400
50
200
200
2,40
400
60
200
200
2,50
400
80
200
200
2,75
400
100
200
200
3,00
We reserve the right to make changes without prior notice
lindab | access doors
Access door
EKTL
Ød
nom
H
mm
a*
mm
b*
mm
m
kg
500
50
200
200
5,40
500
60
500
400
5,70
500
80
500
400
6,40
500
100
500
400
7,00
630
50
500
400
5,40
630
60
500
400
5,70
630
80
500
400
6,40
630
100
500
400
7,00
800
50
500
400
5,40
800
60
500
400
5,70
800
80
500
400
6,40
800
100
500
400
7,00
1000
50
500
400
5,40
1000
60
500
400
5,70
1000
80
500
400
6,40
1000
100
500
400
7,00
1250
50
500
400
5,40
1250
60
500
400
5,70
1250
80
500
400
6,40
1250
100
500
400
7,00
1
2
3
4
5
6
7
8
* Note! Opening dimensions.
9
10
11
12
13
14
15
16
17
18
We reserve the right to make changes without prior notice
659
lindab | access doors
Access door
IPF
Dimensions
1
2
b
3
4
5
a
6
Description
7
Access door, which fits on the flat side of a rectangular duct.
A neoprene cellular gasket seals on the duct's inside.
Supplied with a self adhesive template which guides when
cutting the rectangular aperture.
Can achieve maximum tightness class C.
8
9
a*
mm
180
200
250
300
400
500
600
b*
mm
80
100
150
200
300
400
450
m
kg
0,16
0,33
0,65
1,10
2,10
4,10
4,90
* Note! Opening dimensions.
10
11
12
13
14
15
16
Ordering example
17
Product
Largest side
Smallest side
IPF
250
150
a
b
18
660
We reserve the right to make changes without prior notice
lindab | access doors
Access door
LKCR
Dimensions
45
b
1
2
a
3
45
1
80
4
Non-insulated duct
5
The access door is also used as an inspection hatch for rectangular ducts. To the access door belongs a fixing frame,
which is attached to the rectangular duct. This is normally
done with blind rivets through the folded-down edge of the
done frame. It can also be provided with folding tabs on
request.
It is easy to remove the access door from the fixing frame by
using over-centre catches. In the insulated versions, the
inner side will always be in level with the innermost boundary line of the duct, irrespective of whether the duct is insulated internally or externally. The table below shows the
insulation thickness of the door at different duct insulation
alternatives.
2
6
80
Description
7
Internally insulated duct
8
3
9
Externally insulated duct
Can achieve maximum tightness class C.
The door should not be placed closer than 50 mm from the
nearest side of the rectangular duct.
Maximum square measurement of the access door is
1170×1170 mm.
10
11
12
Ordering example
LKCR 500 300 2 50/100
Product
Largest side
a
Smallest side
b
Non-insulated duct
Type 1
Internally insulated duct
Type 2
Externally insulated duct
Type 3
Duct/cover insulation
30/80 mm (Type 2)
Duct/cover insulation
50/100 mm (Type 2)
Duct/cover insulation
70/120 mm (Type 2)
Duct/cover insulation
100/150 mm (Type 2)
Duct/cover insulation
120/170 mm (Type 2)
Duct/cover insulation
40/60 mm (Type 3)
Duct/cover insulation
50/80 mm (Type 3)
Duct/cover insulation
70/100 mm (Type 3)
Duct/cover insulation
140/160 mm (Type 3)
13
14
15
16
17
18
We reserve the right to make changes without prior notice
661
lindab | access doors
Access door
IPRD
Dimensions
1
2
b
3
4
5
a
6
Description
7
Access door, which fits on the flat side of a rectangular duct.
Consists of a door and a frame. The door has a 25 mm thick
high density insulation. The frame is attached to the duct
wall by means of fixing tabs. Both door and frame are supplied with a rubber gasket.
8
Can achieve maximum tightness class C.
a
mm
300
400
500
9
10
11
12
13
14
15
16
Ordering example
17
Product
Largest side
Smallest side
IPRD
400
300
a
b
18
662
We reserve the right to make changes without prior notice
b
mm
150
300
500
m
kg
1,47
2,46
4,30
lindab | access doors
Access door
IPL
Dimensions
1
2
b
3
4
5
a
Description
Access door, which fits on the flat side of a rectangular duct.
Consists of a door and a frame. The door has a 20 mm thick
high density insulation. The frame is attached to the duct
wall by means of screws. A gasket as well as a retaining
chain is fitted between door and frame.
Can achieve maximum tightness class C.
Size
nom
300 × 150
460 × 250
530 × 360
635 × 430
a
mm
349
502
578
679
b
mm
197
298
400
476
6
m
kg
1,03
2,08
2,70
3,57
7
8
9
10
11
12
13
14
15
16
Ordering example
IPL
460 250
Product