F-Water Heater Domestic hot water module. Domestic hot water module for commercial buildings and multi-family houses. Application The F-Water Heater is based on the charging principle of domestic hot water. The function of the unit is to heat water in a heat exchanger and to transport the domestic hot water into a storage cylinder. The storage cylinder is not included in the delivery. The unit is delivered with an insulated plate heat exchanger. In the standard product program the range covers loads from 69 kW to 1250 kW. This means that middle-sized and larger commercial buildings and multi-family houses with correspondingly large solar collector surfaces can be served by the F-Water Heater. Primary side The primary circuit is the heating supply side of the unit. It consists of a three-way motor valve, pump, air vent, filling/emptying valve. Secondary side The secondary side is the domestic hot water side of the unit. It consists of a safety relief valve, check valve, filling/emptying valve. VL.CW.M1.02 © Danfoss 10/2009 Options Available options are additional ball valves, strainer, balancing valve, charging pump and circulation pump. Further options offered are gasketed heat exchanger, double pumps and insulation. Control The controller, the sensors and the total wiring is included in the delivery. This ensures following function: When the temperature in the top of the domestic hot water cylinder is not at the setpoint, the motor valve opens and the charging pump switches on. The temperature sensor on the primary flow secures a constant flow temperature to the heat exchanger. The charging process continues until the temperature sensor in the bottom of the cylinder signals, that the setpoint temperature has been achieved. Construction The F-Water Heater is built on a floor standing, welded steel frame, and the connections are in the top. The pipes on the primary side are black steel pipes, and on the secondary side stainless steel pipes are used. Most connections are welded and made by nuts and gaskets. FEATURES & BENEFITS • Domestic hot water module • A prefabricated unit secures a unique quality • Constant DHW temperature • Insulated plate heat exchanger • Capacity: 69-1250 kW • Compact design • Easy installation • Minimized risk of lime scale and bacteria formation F-Water Heater Circuit diagram - example 2 5 6 7 8 9 10 12 Plate heat exchanger Strainer Non-return valve Ball valve Primary pump, HE Circulation pump, DHW Charging pump, DHW Safety valve, DHW 10 bar 13 18 25 27 28 33 34 47 50 25 Delivery limit 28 Option 1 HE supply Thermometer 0-120°C Drain valve Controller ECL300/C17 Surface sensor Immersion sensor Actuator 230V 3-port mixing valve Balancing valve Air vent 33 7 8 5 13 50 27 Option 2 7 28 34 DHW 28 2 12 HE return 7 18 47 6 DCW 47 10 7 Circ. Option 3 Technical parameters: Nominal pressure: Maximum temperature: Brazing material (HEX): PN 10 Tmax= 120 °C Copper 1 3 Electrical supply: 230 / 400 V AC 2 4 Dimensions (mm): FWH 69: FWH 1250: H 1410 x W 650 x D 230 H 1860 x W 1400 x D 450 DHW capacity kW 69 82 110 138 185 209 244 274 315 345 Connections sizes: FWH 69 - FWH 138: DN25/DN25/DN25 FWH185: DN32/DN25/DN25 FWH 209 - FWH 244: DN32/DN32/DN25 FWH 274 - FWH 315: DN40/DN32/DN25 FWH 345 - FWH 406: DN40/DN40/DN25 FWH 445 - FWH 464: DN50/DN40/DN25 FWH 522 - FWH 590: DN50/DN50/DN25 FWH 652 - FWH 684: DN65/DN50/DN32 FWH 800 - FWH 1000: DN65/DN65/DN32 FWH 1250: DN80/DN65/DN40 Front view 5 Connections: 1 HE supply 2 HE return 3 DHW 4 DCW 5 Circ. DHW: Capacity examples 10 °C/60 °C FWH 69 FWH 82 FWH 110 FWH 138 FWH 185 FWH 209 FWH 244 FWH 274 FWH 315 FWH 345 10 7 18 6 Type Supply flow primary °C 70 70 70 70 70 70 70 70 70 70 DHW buffer tank Further options: • Double pump • Insulation of pipes • Gasketed heat exchanger • External communication M-Bus • Circulation DHW: Capacity examples 10 °C/60 °C Return flow primary °C 30 30 30 30 30 30 30 30 30 30 Flow rate Secondary l/h 1190 1410 1890 2370 3180 3590 4200 4710 5420 5930 Type FWH 406 FWH 445 FWH 464 FWH 522 FWH 590 FWH 652 FWH 684 FWH 800 FWH 1000 FWH 1250 DHW capacity kW 406 445 464 522 590 652 684 800 1000 1250 Supply flow primary °C 70 70 70 70 70 70 70 70 70 70 Return flow primary °C 30 30 30 30 30 30 30 30 30 30 Flow rate Secondary l/h 6980 7650 7980 8980 10150 11210 11760 13760 17200 21500 * Pump excess pressure of 10 kPa primary and 15 kPa secondary Danfoss A/S · DK-6430 Nordborg · Denmark · Tel.: +45 74 88 22 22 · Fax: +45 74 49 03 95 E-mail: heating@danfoss.com · www.dh.danfoss.com VL.CW.M1.02 © Danfoss 10/2009 DKDHR