EMI Power Filters CERTIFIED Signal & Power Integrity Group EMI Power Filters Spectrum Control EMI filtered power products prevent unwanted interference from entering your system, as well as eliminate emissions that can contaminate the AC power grid. Our standard and custom products are available in a wide range of AC/DC current and voltage ratings to address EMI filtering for high current applications. All Spectrum power products are designed to meet global EMC emissions regulations. Spectrum Control is committed to providing an integrated approach to EMC problem solving by offering customers consulting, diagnostic testing, design and manufacturing services. As a fully integrated manufacturer, Spectrum Control is able to respond to short lead time requests for new prototypes and variations to standard products. This enables us to provide the most costeffective solution that satisfies both your performance and budgetary needs. In addition, our family of power products provide low cost solutions to EMI challenges, helping you lower inventories and increase production assembly efficiency. Spectrum Control power products are used in a variety of industries worldwide, including telecommunications, computers and peripherals, medical, aerospace, military, power supplies, appliances and industrial controls. CERTIFIED 2 Signal & Power Integrity Group A Control Products Systems Company & Spectrum Control Inc... Page • DC Single Line Feed-thru Series • AC Single Line Feed-thru Series • DC Single Line Pi Series • AC Single Line Pi Series 12 - 22 • Single Line Feed-thru Filters Single Line Filters High Current Filtered Terminal Blocks Power Entry Modules • Fused Filtered Power Entry Modules • Switched & Fused Filtered Power Entry Modules • Switched & Fused Filtered Power Entry Modules For European Market 24 - 51 • Miniature Printed Circuit Boards • Power Entry Modules Bolt-in Right Angle Terminals • Power Entry Modules High Frequency Attenuation Bolt-in • PCB Power Filters Miniature Printed Circuit Boards 52 - 59 • Appliance Filters • Single Stage • Single Stage Wire Leads • Single Stage Wire Leads for Medical Purpose Applications • Single Stage - Higher Current • Three Phase - Low Current/High Performance • DC - Higher Current • Three Phase • DC - Single Stage • Dual Stage • Three Phase - High Performance Bolt-in Rear Terminals Bolt-in Right Angle Terminals High Frequency Attenuation Snap-in With Wire Leads Bolt-in With Wire Leads Snap-in Mount PCB Power Filters Power Line Filters Military/Aerospace Multisection Filters Custom/Application Specific Filters Appendix 23 • High Current Filtered Terminal Blocks 60 - 97 • Military/Aerospace Multisection Filters 98 - 105 • Custom/Application Specific Filters 106 - 109 • Part Number Index • Design Inquiry Form • www.spectrumcontrol.com Online tools 110 - 115 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 3 EMI Power Filters Selection Guide Applications High Current Terminal Blocks Cellular base stations, telephone racks, high current switch mode power supplies, power amplifiers and servers Cellular base stations, telecommunication switching networks, hi-reliability radar & transmission systems, industrial controls, power supplies, UPS, instrumentation and power distribution Digital equipment, personal computers and peripherals, measuring instruments, home appliances, monitor and display units Digital equipment, personal computers and peripherals, measuring instruments, home appliances, monitor and display units ■ Easy installation Bolt-in style, surface mount ■ Rugged construction Provides protection to filtering element; especially useful for repeated in-field wiring changes ■ Rugged construction Designed to perform in industrial environments ■ Design flexibility Available in PCB mount, fast-on tab, solder lug or flying leads ■ Performance Ideally suited for products that must conform to FCC part 15 regulations Meets over-voltage of IEC 664 category II and complies with IEC 950 Metal case provides maximum isolation that optimizes performance ■ Agency approvals UL recognized, CSA certified, TÜV approved (tested and found to be in accordance with VDE 0565 Part 3) ■ Custom options Value added connectors, wire leads, ring terminals ■ Rugged construction Designed to perform in industrial environments ■ Current ratings (max.) Up to 15 Amps ■ Voltage ratings (max.) From DC to 250 VAC, 60 Hz ■ Insertion loss range Effective filtering from 100 KHz to 30 MHz ■ Temperature range -25°C to +85°C ■ Leakage current range 0.35 mA to 0.50 mA max ■ Current ratings (max) 2, 4 and 6 Amps ■ Voltage ratings (max.) 125 VAC and 250 VAC ■ Insertion loss range Effective filtering from 100 KHz to 30 MHz ■ Temperature range -25°C to +85°C ■ Leakage current range 0.35 mA to 0.50 mA max for general purpose filters 0.005 mA to 0.10 mA max for medical filters Pages 42-51 ■ Design flexibility Available with single, dual, triple and quad configurations, different stud lengths, mounting brackets hardware and EMI gasketing available. ■ Performance Ideally suited to help meet NEBS, GR1089, and EN55022 Features/ Benefits ■ Agency approvals Designed to meet agency approvals, some selected filters UL 1950 recognized, CSA C22.2 certified and TÜV approved ■ Custom options Custom interfacing, contact pins, wire leads, multiple outputs ■ Design flexibility 2 x 2 to 2 x 6 position blocks Terminal Blocks available with either metric or US threaded studs ■ Performance Filter elements provide high insertion loss for EMI filtering of DC power lines to help meet NEBS, GR1089, and EN55022 ■ Agency approvals UL recognized ■ Environmental Can be used in both indoor and outdoor applications Performance Characteristics For data sheets on the product you’re looking for, enter the dedicated URL 4 ■ Current ratings (max) To 500 Amps ■ Voltage ratings (max) To 1000 VDC and to 240 VAC ■ Insertion loss range AC: 1 MHz to 1 GHz DC: 150 KHz to 10 GHz ■ Temperature range -55°C to +125°C ■ Capacitance To 4.7 µF Class Y2 and Y4 available Pages 12-22 www.spectrumcontrol.com/sfilter ■ Current ratings (max.) Barrier strip: 60 Amps ■ Voltage ratings (max.) From 100 VDC to 250 VAC, 60 Hz ■ Insertion loss range Effective insertion loss from 1 MHz to 200 MHz ■ Temperature range -55°C to +105°C ■ Capacitance .015 µF per line or .030 µF per pair Pages 23 www.spectrumcontrol.com/terblk Power Entry Modules Power Entry Modules Fused/Switched and Fused High Current Feed-thru Filters Pages 24-41 www.spectrumcontrol.com/pem ■ Design flexibility Bolt-in or snap-in mounting Available in fused or switched and fused versions ■ Performance Ideally suited for products that must conform to FCC part 15 regulations Meets over-voltage of IEC 664 category II and complies with IEC 950 Low leakage versions available for medical applications ■ Agency approvals UL recognized, CSA certified, TÜV approved (tested and found to be in accordance with VDE 0565 Part 3) www.spectrumcontrol.com/pemfsf SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 EMI Power Filters Selection Guide Power Line Filters Applications Commercial Custom Assemblies Digital equipment, industrial equipment, UPS, inverters, converters, automation equipment, computerized industrial washing machines, and switching power supplies Commercial & military avionics, satellites, secured communications, ruggedized computers, radar, electronic warfare, and ground/air weapon systems Telecommunications, cellular base stations, medical equipment, telephone switching, traffic control systems, industrial work stations, servers, power supplies, UPS, industrial controls and welders ■ Rugged construction Designed to perform in industrial environments ■ Rugged construction Designed to perform in industrial environments ■ Rugged construction Designed to perform in industrial environments ■ Design flexibility Available with fast-on, bolt-in terminals or wire leads ■ Design flexibility Available with fast-on or bolt-in terminals ■ Rugged construction Metal enclosures built to withstand MIL-STD environmental conditions Single stage and dual stage Single and dual stage High performance in both metal and plastic cases Excellent attenuation for high voltage impulse ■ Agency approvals Several styles are UL recognized, CSA certified, TÜV approved (tested and found to be in accordance with VDE 0565 Part 3) Performance Characteristics Military/Aerospace Multisection Filters Digital equipment, personal computers and peripherals, measuring instruments, medical, industrial, telecommunications equipment, factory automation, UPS, vending machines, elevators, and switch mode power supplies ■ Performance Ideally suited for products that must conform to FCC part 15 regulations Features/ Benefits Three-Phase Power Line Filters ■ Current ratings (max) To 260 Amps ■ Voltage ratings (max.) From DC to 250 VAC, 60 Hz ■ Insertion loss range Effective filtering from 100 KHz to 30 MHz ■ Temperature range -25°C to +85°C ■ Leakage current range 0.35 mA to 3.0 mA max Pages 52-87 www.spectrumcontrol.com/pline Delta and Wye configurations ■ Performance Ideally suited for products that must conform to FCC part 15 regulations Both metal and plastic cases provide high performance Excellent attenuation for high voltage impulse ■ Agency approvals Agency approvals pending ■ Current ratings (max) 3 Amp to 200 Amps ■ Voltage ratings (max.) 250 VAC to 440 VAC ■ Insertion loss range Effective filtering from 100 KHz to 30 MHz ■ Temperature range -40°C to +85°C ■ Leakage current range Standard and low leakage designs available Pages 88-97 www.spectrumcontrol.com/3pline ■ Design flexibility Standard catalog parts available Parts designed to meet customers’ requirements ■ Performance EMI designs provide excellent isolation and high frequency performance ■ Military approvals Available to meet MIL-F15733 and MIL-STD-461 Military testing IAW MILSTD-202, MIL-STD-105 ■ EMI design verification Equipment verification can be accomplished through Spectrum Control’s EMI test lab ■ Current ratings (max.) Up to 100 Amps ■ Voltage ratings (max.) 400 VDC and 240 VAC standard; custom voltage ratings available ■ Insertion loss range Effective filtering from 10 KHz to 10 GHz ■ Temperature range -55°C to +125°C Pages 98-105 www.spectrumcontrol.com/multi ■ Design flexibility Filters designed to meet customer’s circuit requirements Transient protection Circuit breakers Voltage cut-off Other options available Provides quick and economical solutions to meet customers’ specific requirements Increases speed-to-market and decreases development time Designs optimized through EMC verification ■ Agency approvals Designed to meet NEBS and safety agency approvals ■ Current ratings (max.) Up to 250 Amps ■ Voltage ratings (max.) 400 VDC and 240 VAC standard; custom voltage ratings available ■ Insertion loss range Effective filtering from 10 KHz to 10 GHz ■ Temperature range -55°C to +125°C ■ Leakage current range Standard and low leakage designs available Pages 106-109 www.spectrumcontrol.com/comcus SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 5 Spectrum Control’s Expertise Spectrum Control is unique in providing an integrated approach to EMC problem solving by offering customer consulting, diagnostic testing, design and manufacturing services. As a fully integrated manufacturer, we are able to respond to short lead times and develop cost-effective solutions to satisfy your performance and budgetary needs. Test ■ ■ ■ ■ Spectrum Control’s Test Facility provides a total solution for your compliance issues In-house anechoic chamber and shielding room NARTE certified engineering staff Tests available for: • European emission and immunity regulations (CE Mark) • FCC Part 15 • MIL standard testing Design ■ ■ ■ ■ In-house EMI and power conditioning specialists Comprehensive computer modeling Designs are “in-house” compliance verified Custom assemblies: • Incorporate EMI filtering, circuit breaker protection, transient suppression, voltage cut-off, power factor correction, harmonic suppression, remote sensing and other options to meet your specific requirements • Plug-and-play designs • Reduce your time to market • Lower your inventory needs Manufacture ■ ■ ■ ■ ■ 6 Flexible factories Custom designs Spectrum Control, Inc. ISO 9001 certified Schedule sharing programs available Vertically integrated supplier SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Spectrum Control’s Expertise As a complete source of EMC solutions, Spectrum Control combines state-of-the-art test facilities with proven expertise in the design and manufacture of EMI/RFI filtered power products. Spectrum Control offers: Engineering Support – Our experienced engineering staff will work closely with your design and manufacturing team to provide rapid and cost-effective solutions meeting the most stringent EMI requirements. Reduced Lead Times and Volume Production – Our vertical integration allows us to reduce lead times for both prototype and production orders . . . ensuring on-time delivery. This not only reduces your inventory, it saves you time and money. Custom Solutions – We offer maximum design expertise and versatility to meet the need of any unique filtering application. In addition, we’ll develop power conditioning solutions with features such as back panels with EMI filtering and surge protection, circuit breakers, LEDs and voltage cut-off. Full Qualification Testing – We offer a fully integrated quality assurance process, as well as testing in compliance with MIL-F-28861, MIL-F-15733, MIL-STD-202, and other EMI specifications. Spectrum Control’s facilities have been audited and qualified to MIL-I-45208 and are registered to ISO 9001. Customer Support Programs – We will work closely with your organization to help improve the final design and performance of your products, as well as increase your manufacturing and operational efficiency. Spectrum Control has instituted a variety of programs designed to maximize these opportunities. ■ Flexible manufacturing to cut cycle times and meet deadlines ■ EDI to streamline the transmitting of information ■ Inventory Management through flexible shipping programs ■ Consignment/schedule sharing programs to accommodate customers’ forecasts ■ Broader distribution base to make our products more readily available and accommodate vendor reduction plans ■ New product development geared to meeting customer-specific requirements and targets SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 7 Application Guidelines Need for EMI suppression Global regulatory agencies have established limits to the amount of noise that man-made electronic devices can radiate or conduct. These regulations have gained greater importance as the world’s electronic population intensifies and the proximity of electronic devices becomes closer. Power Filter Installation EMI can propagate through two basic avenues: Conducted and Radiated Conducted refers to events where the EMI energy flows through power lines, data cables and other wiring that carries functional data or power. Radiated refers to energy that is propagated by magnetic or electric fields, which originate from other electronic or electrical systems. INCORRECT CORRECT CABINET POWER INPUT DENOTES COUPLING FROM NOISY CIRCUITS BACK TO LINE CABINET DENOTES COUPLING FROM NOISY CIRCUITS BACK TO LINE POWER INPUT Interference types There are two modes of conducted noise: differential mode (symmetrical or normal mode) and common mode (asymmetrical mode). Differential mode interference signals are present on one side of the line, referenced to the other. The currents flow along one phase and return along another phase. Common mode interference signals are present on both sides of the line referenced to ground. The current flows from the source to ground along the ground path and returns along the phases. Sources of EMI Electromagnetic interference can occur naturally or through electronic sources. Lightning discharges, precipitation, sand and dust storms, and cosmic noise are sources of natural EMI. EMI generated from power electrical products cause the most concern. These man-made sources, such as power lines, rotating machinery, power supplies and electronic transmission devices, all have their own signatures and noise pollution. EMI filters, insertion loss and attenuation Power line EMI filters are designed to attenuate (or reduce) all radio frequency emissions or energy that is above the applicable EMC specification. Most power line EMI filters utilize inductor/capacitor “low pass” component configurations that pass all DC or low frequency AC necessary energy and attenuate (suppress) higher frequencies containing noise or unwanted energy. 8 LINE FILTER CLEAN LINE LINE FILTER To insure a customer’s “in system” unit to unit attenuation uniformity of power line filters, an insertion loss production line test is performed by Spectrum Control, Inc. Each of the specific frequencies is measured using RF test equipment and the “reference signal level” of each frequency is stored. Some systems sweep the entire frequency range and store this “reference signal level”. The filter to be measured, tested, or evaluated is then “inserted” between the generator and receiver that established the stored “reference signal level” on the RF test analyzer. The measured difference without a filter (“the reference signal level”) and with the filter “inserted” into the RF test equipment/analyzer is defined as insertion loss. The unit of measure for insertion loss is the decibel (dB). As noted on most curves in this bulletin, as frequency increases, the higher the insertion loss or dB value. The plot of frequency versus dB value establishes the typical insertion loss curve. Installation Criteria Proper installation of a filter network is critical to achieving successful filtering of electromagnetic interference. Spectrum Control recommends that power line filters be installed where the power line enters the equipment. The filter acts as a barrier between polluted energy and clean energy going into your equipment. It is important that the filter is connected to an effective ground plane and where proximity does not couple radiated noise to the clean lines. SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Measurement Guidelines Spectrum Control has the capability to perform a wide range of tests for EMI filters. Unique custom testing systems, designed by Spectrum Control assure the accuracy required in today’s demanding environments. Testing is performed by employing a 50 ohm source and load impedance per MIL-STD-220. The individual filter performance is stated in terms of insertion loss. Overall attenuation reflects the filter’s interaction within the system. Individual filter performance may differ from system to system and each application should be verified through system testing. Examples of various testing abilities and configurations are outlined below. Differential (Normal or Symmetrical) Mode Insertion Loss Differential mode noise is caused by non-sinusoidal conduction of rectifiers and other switching devices creating harmonic distortion. This noise is predominant from the power frequency to approximately 10 MHz. Since it follows conventional current flow, it is considered to be of the same magnitude but opposite phase of the other line. Spectrum Control measures differential mode insertion loss in a 50 ohm system with Balun transformers as shown. Leakage Current Leakage is a measurement of reactive current (capacitance) to ground per line. Spectrum Control uses the following test setup for leakage current measurement. TIES TO CHASSIS OF DEVICE DEVICE UNDER TEST 1 AC SOURCE 2 0.15 µFD 1 NEUTRAL TEST 2 HIGH TEST 1.5 KΩ v IN ACCORDANCE WITH U.L. 1283 METHOD AC Voltage Drop AC voltage drop is defined as E in - E out = AC voltage drop. Spectrum Control uses the following circuit for AC voltage drop testing: A DUT (FILTER) E1 BALUN INSULTATED TABLE E2 BALUN FILTER ØA 50Ω FILTER ØB SIGNAL GENERATOR 50Ω RECEIVER Common (Asymmetrical) Mode Insertion Loss E VD Since common mode insertion loss is of the same phase as the opposite line, they may not be of the same magnitude, depending on the end system circuitry. Spectrum Control tests common mode insertion loss on each line in a 50 ohm system as shown. LINE DUT (FILTER) A RS LINE 50Ω 50Ω FILTER NEUT DC Voltage Drop DC voltage drop is performed on each line individually. This test provides the total DC voltage drop for that line of the filter. The following circuit is used in testing: FILTER ØC RECEIVER NEUT SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 9 EMC Testing Solutions Spectrum Control is a solutions-oriented EMC test corporation committed to effectively satisfying worldwide EMC standards for commercial and military equipment. Our EMC testing services offer you a flexible resource to assist in product development by identifying and correcting EMI susceptibility and/or emission problems. Our commitment to our customers goes much further than any other EMI filtered power products manufacturer. Spectrum Control has a fully equipped EMC Test Laboratory and experienced engineering staff ready to solve your most demanding EMC challenges. We can test your equipment, system or subsystem to various domestic and international regulatory standards, determine state of compliance, and develop the most compact and cost-effective solution. These services (EMC testing and compliance recommendations) are available for a modest daily fee. It is not uncommon for clients leave Spectrum Control’s EMC Test Laboratory with a prototype in hand. State-of-the-art Testing ■ ■ ■ ■ ■ Two test environments available: anechoic chamber and shielded room Baseline of device under test in ambient-free anechoic chamber Computer controlled pre-selected EMI receivers with quasi-peak detection accumulate data for displaying information in graphical or tabular formats Fiber optic coupled video cameras for dynamic test observation Computer generated test data reduces time and improves accuracy Testing Capabilities UL Underwriter’s Laboratories, UL 1283 MILITARY MIL-STD-461 A/B/C/D and MIL-STD-1399 AUTOMOTIVE SAE-J1113, SAE-J551 COMMERCIAL FCC-Part 15 RTCA-DO-160 A/B/C Boeing-16050-2 Bellcore-TR-NWT-001089 INTERNATIONAL EN 55011 (CISPR 11) EN 55014 (CISPR 14) EN 55022 (CISPR 22) IEC-1000-4-02 ESD IEC-1000-4-03 RFI IEC-1000-4-04 EFT IEC-1000-4-05 Surge 10 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 EMC Testing Solutions One of the most significant advantages of Spectrum Control’s testing services lies in our experience and expertise in evaluating, designing and producing products for the suppression of EMI. Our approach to EMC testing enables us to identify, as well as solve any problems or potential problems found in your system. Spectrum’s design and production engineers will work with your engineering team to develop a filter solution that eliminates your EMI problems. Once we have identified an EMI failure, we will develop a prototype design, integrate the EMC modification into your device or system, and verify compliance to the appropriate test specifications. Spectrum Control maintains semi-automated and automated manufacturing facilities to economically produce the modification installed during testing. Through these capabilities your equipment will leave Spectrum Control with a prototype, as well as a fully compliant system. Test ■ ■ ■ ■ Spectrum Control Test Facility will define compliance issues In-house anechoic chamber and shielded room NARTE certified engineering staff Test available for: • European emission and immunity regulations • FCC Part 15 • MIL 461 Series Design ■ ■ ■ ■ ■ In-house EMI specialists Computer modeling CAD systems internet accessible Designs are “in-house” compliance verified Value-added designs: • Incorporate circuits and additional components • Ease of production assembly • Lower inventory needs Manufacture ■ ■ ■ ■ ■ ■ Flexible operations Custom designs built in U.S.A. ISO 9001 certified facilities Workmanship MIL-STD-2000 certified Schedule sharing programs available Vertically integrated EMI filter supplier SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 11 High Current DC Single Line Feed-thru Series Features ■ ■ ■ ■ Single Line Filters ■ ■ ■ ■ ■ Voltage Rating 130VDC C Configuration with Class Y4 capacitors Current rating up to 300 Amps Operating Temperature Range: -40C to +85C Excellent filtering in compact package Bolt-in style with D-shaped bushing for easy installation Low cost EMI solution Design flexibility UL and Semko approved Applications ■ ■ ■ ■ ■ ■ Telecommunications (cellular base stations, telephone switching racks, etc.) Power supplies Medical Equipment C.O.T.S. (Commercial-Off-The-Shelf) Military Industrial equipment controls Data Transmission Equipment Specifications Part Number 52-226-011-10 52-226-011-16 52-226-011-32 52-226-011-63 52-226-011-100 52-226-011-200 52-226-011-250 52-226-011-300 52-226-021-16 52-226-021-32 52-226-031-63 52-226-021-100 52-226-021-200 52-226-021-250 52-226-021-300 52-226-031-16 52-226-031-32 52-226-031-63 52-226-031-100 52-226-031-200 52-226-031-250 52-226-031-300 52-226-041-16 52-226-041-32 52-226-041-63 52-226-041-100 52-226-041-200 Rated Current 10A 16A 32A 63A 100A 200A 250A 300A 16A 32A 63A 100A 200A 250A 300A 16A 32A 63A 100A 200A 250A 300A 16A 32A 63A 100A 200A Min. Cap. .01MHz 10nF .10MHz Minimum Insertion Loss (db)* 1MHz 10MHz 100MHz 1000MHz – 4 21 41 60 2 15 34 53 74 100nF 5 21 40 60 85 47nF 2 15 34 53 74 100nF 5 21 40 60 85 47nF – 470nF 2 16 33 52 75 90 100nF – 5 21 40 60 85 470nF 2 16 33 52 75 1000nF 6 20 40 60 85 470nF 2 16 33 52 75 1000nF 4700nF 6 15 20 35 40 54 60 74 85 90 90 * Optimum performance with proper installation 12 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 High Current DC Single Line Feed-thru Series B E WORKORDER NO. C Single Line Filters F D DATE CODE SINGLE "D" MOUNTING FLAT .025 (.64) SHOULDER A Dimensions Part Number 52-226-011-10 52-226-011-16 52-226-011-32 52-226-011-63 52-226-011-100 52-226-011-200 52-226-011-250 52-226-011-300 52-226-021-16 52-226-021-32 52-226-031-63 52-226-021-100 52-226-021-200 52-226-021-250 52-226-021-300 52-226-031-16 52-226-031-32 52-226-031-63 52-226-031-100 52-226-031-200 52-226-031-250 52-226-031-300 52-226-041-16 52-226-041-32 52-226-041-63 52-226-041-100 52-226-041-200 A B C D E 2.24 (57) 0.39 (10) 0.51 (13) 0.56 (14.29) 0.63 (16) 2.48 (63) 0.47 (12) 0.67 (17) 0.75 (19.05) 0.71 (18) 3.78 (96) 4.45 (113) 5.12 (130) 0.55 (14) 0.63 (16) 0.87 (22) 1 (25.40) 1.18 (30) 1.06 (27) 1.25 (31.75) 1.02 (26) 1.26 (32) 1.57 (40) 1.57 (40) 2 (50.80) 1.81 (46) 1.65 (42) 5.83 (148) 0.75 (19) F 2.95 (75) 0.47 (12) 0.67 (17) 0.75 (19.05) 0.71 (18) 3.78 (96) 4.45 (113) 5.12 (130) 0.55 (14) 0.63 (16) 0.87 (22) 1 (25.40) 1.06 (27) 1.25 (31.75) 1.02 (26) 1.26 (32) 1.57 (40) 1.57 (40) 2 (50.80) 1.81 (46) 6.30 (160) 0.75 (19) 0.71 (18) 1.30 (33) 1.18 (30) 1.30 (33) 2.13 (54) 2.95 (75) 0.47 (12) 0.67 (17) 0.75 (19.05) 0.71 (18) 3.78 (96) 4.45 (113) 5.79 (147) 0.55 (14) 0.63 (16) 0.87 (22) 1 (25.40) 1.25 (31.75) 1.5 (38.10) 1.02 (26) 1.26 (32) 1.57 (40) 1.30 (33) 1.97 (50) 2 (50.80) 1.81 (46) 2.83 (72) 7.01 (178) 3.23 (82) 3.98 (101) 5.24 (133) 6.50 (165) 0.75 (19) 0.63 (16) 0.75 (19) 1.06 (27) 1.57 (40) 1.06 (27) 1.57 (40) 1.25 (31.75) 1.5 (38.10) 2 (50.80) 0.71 (18) 1.02 (26) 1.26 (32) 1.57 (40) 1.18 (30) 1.30 (33) 1.97 (50) 2.68 (68) Dimensions in inches (mm) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 13 High Current DC Single Line Pi Series Features ■ ■ ■ ■ Single Line Filters ■ ■ ■ Voltage Rating 130VDC Pi Configuration with Class Y4 capacitors Current rating up to 200 Amps Excellent filtering in compact package Bolt-in style with D-shaped bushing for easy installation Low cost EMI solution UL and Semko approved Applications ■ ■ ■ ■ ■ ■ Telecommunications (cellular base stations, telephone switching racks, etc.) Power supplies Medical Equipment C.O.T.S. (Commercial-Off-The-Shelf) Military Industrial equipment controls Data Transmission Equipment Circuit Diagram Specifications Part Number Standard Performance 52-226-020-10 52-226-020-16 52-226-020-32 52-226-020-63 52-226-020-100 52-226-020-200 High Performance 52-226-029-10 52-226-029-16 52-226-029-32 52-226-029-63 52-226-029-100 52-226-029-200 Rated Current 10A 16A 32A 63A 100A 200A 10A 16A 32A 63A 100A 200A Min. Cap. (2X) 10nF .01MHz – .10MHz Minimum Insertion Loss (db) * 1MHz 10MHz 100MHz 0.5 8 10 27 23 35 23 67 70 60 470nF 4 7 2 8 21 23 100nF – 8 25 75 470nF 1000nF 4700nF 4 8 20 21 26 40 35 57 85 70 73 90 100nF 30 1000MHz 70 50 90 90 90 90 * Optimum performance with proper installation 14 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 High Current Single Line Filters DC Single Line Pi Series A B F E C D SINGLE "D" MOUNTING FLAT DATE CODE WORKORDER NO. .025 (.64) SHOULDER Dimensions Part Number Standard Performance 52-226-020-10 52-226-020-16 52-226-020-32 52-226-020-63 52-226-020-100 52-226-020-200 High Performance 52-226-029-10 52-226-029-16 52-226-029-32 52-226-029-63 52-226-029-100 52-226-029-200 A B C D 0.47 (12) 0.67 (17) 0.75 (19.05) 0.55 (14) 0.63 (16) 0.75 (19) 0.87 (22) 1 (25.40) 1.25 (31.75) 1.50 (38.10) 0.47 (12) 0.67 (17) 3.54 (90) 3.86 (98) 6.30 (160) 7.24 (184) 8.23 (209) 1.06 (27) 5.12 (130) 5.47 (139) 6.81 (173) 8.98 (228) 11 (279) 0.63 (16) 0.75 (19) 1.06 (27) 1.57 (40) 0.75 (19.05) 1.25 (31.75) 1.50 (38.10) 2 (50.80) E F 0.63 (16) 1.93 (49) 0.71 (18) 2.09 (53) 1.02 (26) 1.26 (32) 1.57 (40) 3.70 (94) 4.09 (104) 4.41 (112) 0.63 (16) 3.50 (89) 0.71 (18) 3.70 (94) 1.02 (26) 1.26 (32) 1.57 (40) 4.13 (105) 5.71 (145) 7.17 (182) Dimensions in inches (mm) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 15 High Current AC Single Line Feed-thru Series Features ■ ■ ■ ■ ■ Single Line Filters ■ ■ ■ Voltage Rating 250VAC C Configuration with Class Y2 capacitors Current rating up to 300 Amps Excellent filtering in compact package Bolt-in style with D-shaped bushing for easy installation Low cost EMI solution Design flexibility UL and Semko approvals pending Applications ■ ■ ■ ■ ■ ■ Telecommunications (cellular base stations, telephone switching racks, etc.) Power supplies Medical Equipment C.O.T.S. (Commercial-Off-The-Shelf) Military Industrial equipment controls Data Transmission Equipment Specifications Part Number 52-226-016-10 52-226-016-16 52-226-016-32 52-226-016-63 52-226-016-100 52-226-016-200 52-226-016-250 52-226-016-300 52-226-026-10 52-226-026-16 52-226-026-32 52-226-026-63 52-226-026-100 52-226-026-200 52-226-026-250 52-226-026-300 52-226-036-16 52-226-036-32 52-226-036-63 52-226-036-100 52-226-036-200 52-226-036-250 52-226-036-300 52-226-046-16 52-226-046-32 52-226-046-63 52-226-046-100 52-226-046-200 52-226-046-250 52-226-046-300 Rated Current Min. Cap. 10A 16A 32A 63A 100A 200A 250A 300A 10A 16A 32A 63A 100A 200A 250A 300A 16A 32A 63A 100A 200A 250A 300A 16A 32A 63A 100A 200A 250A 300A 2.2nF .01MHz .10MHz Minimum Insertion Loss (db) * 1MHz 10MHz 100MHz 1000MHz - 9 30 45 4.7nF – 2 15 34 54 10nF 47nF 2 4 15 21 34 41 53 60 74 100nF 5 21 40 60 85 2 15 34 54 4 21 41 60 4.7nF 10nF – – 47nF 100nF 2 5 15 21 34 40 53 60 74 85 220nF 10 27 47 67 90 47nF 33nF 100nF 220nF 2 3 5 10 15 16 21 27 34 35 40 47 16 33 52 75 2 5 2 10 16 21 15 27 33 40 34 47 52 60 53 67 75 6 20 40 60 85 470nF 100nF 47nF 220nF 470nF 2 – 53 60 67 74 90 85 90 85 74 90 1000nF * Optimum performance with proper installation 16 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 High Current AC Single Line Feed-thru Series B F WORKORDER NO. Single Line Filters C E D SINGLE "D" MOUNTING FLAT DATE CODE .025 (.64) SHOULDER A Dimensions Part Number 52-226-016-10 52-226-016-16 52-226-016-32 52-226-016-63 52-226-016-100 52-226-016-200 52-226-016-250 52-226-016-300 52-226-026-10 52-226-026-16 52-226-026-32 52-226-026-63 52-226-026-100 52-226-026-200 52-226-026-250 52-226-026-300 52-226-036-16 52-226-036-32 52-226-036-63 52-226-036-100 52-226-036-200 52-226-036-250 52-226-036-300 52-226-046-16 52-226-046-32 52-226-046-63 52-226-046-100 52-226-046-200 52-226-046-250 52-226-046-300 A B C D E 2.24 (57) 0.39 (10) 0.51 (13) 0.56 (14.29) 0.63 (16) 2.48 (63) 0.47 (12) 0.67 (17) 0.75 (19.05) 0.71 (18) 3.78 (96) 4.45 (113) 5.12 (130) 0.55 (14) 0.63 (16) 0.87 (22) 1 (25.40) 1.25 (31.75) 1.5 (38.10) 1.02 (26) 1.26 (32) 1.57 (40) 1.18 (30) 1.57 (40) 2 (50.80) 1.81 (46) 1.65 (42) 5.83 (148) 0.75 (19) 1.06 (27) F 0.71 (18) 1.30 (33) 2.24 (57) 0.39 (10) 0.51 (13) 0.56 (14.29) 0.63 (16) 2.48 (63) 0.47 (12) 0.67 (17) 0.75 (19.05) 0.71 (18) 3.78 (96) 4.45 (113) 5.12 (130) 0.55 (14) 0.63 (16) 0.87 (22) 1 (25.40) 1.25 (31.75) 1.5 (38.10) 1.02 (26) 1.26 (32) 1.57 (40) 1.18 (30) 1.57 (40) 2 (50.80) 1.81 (46) 1.65 (42) 5.83 (148) 0.75 (19) 1.06 (27) 0.71 (18) 1.30 (33) 2.95 (75) 0.47 (12) 0.67 (17) 0.75 (19.05) 0.71 (18) 3.78 (96) 4.57 (116) 5.79 (147) 0.55 (14) 0.87 (22) 1.06 (27) 1 (25.40) 1.02 (26) 1.26 (32) 1.57 (40) 1.30 (33) 1.97 (50) 2 (50.80) 1.81 (46) 2.13 (54) 0.87 (22) 0.67 (17) 1 (25.40) 0.71 (18) 1.18 (30) 1.06 (27) 1.25 (31.75) 1.5 (38.10) 1.02 (26) 1.26 (32) 1.57 (40) 1.30 (33) 1.81 (46) 2.13 (54) 0.75 (19) 6.30 (160) 3.03 (77) 2.95 (75) 4.45 (113) 5.24 (133) 5.79 (147) 6.30 (160) 0.55 (14) 0.47 (12) 0.63 (16) 0.75 (19) 1.57 (40) 1.57 (40) 1.5 (38.10) 2 (50.80) 1.18 (30) 1.97 (50) Dimensions in inches (mm) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 17 High Current AC Single Line Pi Series Features ■ ■ ■ ■ Single Line Filters ■ ■ ■ ■ Voltage Rating 250VAC Pi Configuration with Class Y2 capacitors Current rating up to 300 Amps Excellent filtering in compact package Bolt-in style with D-shaped bushing for easy installation Low cost EMI solution Design flexibility UL and Semko approvals pending Circuit Diagram Applications ■ ■ ■ ■ ■ ■ Telecommunications (cellular base stations, telephone switching racks, etc.) Power supplies Medical Equipment C.O.T.S. (Commercial-Off-The-Shelf) Military Industrial equipment controls Data Transmission Equipment Specifications Part Number Standard Performance 52-226-037-10 52-226-037-16 52-226-037-32 52-226-037-63 52-226-037-100 52-226-037-200 52-226-037-250 52-226-037-300 High Performance 52-226-019-10 52-226-019-16 52-226-019-32 52-226-019-63 52-226-019-100 52-226-019-200 52-226-019-250 52-226-019-300 Rated Current Min. Cap. (2X) 10A 16A 32A 63A 100A 200A 250A 300A 4.7nF 10A 16A 32A 63A 100A 200A 250A 300A 10nF .01MHz – 47nF 100nF 1 10nF 22nF – .10MHz Minimum Insertion Loss (db) * 1MHz 10MHz 100MHz – 4 19 77 1 8 22 50 4 8 21 25 52 73 80 9 26 75 1 9 30 3 15 47 27 39 75 150nF 1 12 470nF 4 21 57 85 1000MHz 90 90 80 90 90 * Optimum performance with proper installation 18 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 High Current AC Single Line Pi Series Single Line Filters A B F E C D SINGLE "D" MOUNTING FLAT DATE CODE WORKORDER NO. .025 (.64) SHOULDER Dimensions Part Number Standard Performance 52-226-037-10 52-226-037-16 52-226-037-32 52-226-037-63 52-226-037-100 52-226-037-200 52-226-037-250 52-226-037-300 High Performance 52-226-019-10 52-226-019-16 52-226-019-32 52-226-019-63 52-226-019-100 52-226-019-200 52-226-019-250 52-226-019-300 A B C D E F 0.47 (12) 0.67 (17) 0.75 (19.05) 0.63 (16) 0.71 (18) 2.24 (57) 2.40 (61) 0.55 (14) 0.63 (16) 0.87 (22) 1 (25.40) 1.25 (31.75) 1.02 (26) 1.26 (32) 1.57 (40) 3.7 (94) 4.09 (104) 4.41 (112) 1.81 (46) 3.66 (93) 3.86 (98) 4.17 (106) 6.30 (160) 7.24 (184) 8.23 (209) 7.87 (200) 0.75 (19) 1.06 (27) 1.57 (40) 1.5 (38.10) 4.21 (107) 0.47 (12) 0.67 (17) 0.75 (19.05) 0.63 (16) 2.6 (66) 4.57 (116) 0.55 (14) 0.87 (22) 1 (25.40) 0.71 (18) 2.72 (69) 6.81 (173) 8.98 (228) 9.57 (243) 0.63 (16) 1.06 (27) 1.25 (31.75) 1.5 (38.10) 1.02 (26) 1.26 (32) 4.13 (105) 5.71 (145) 5.75 (146) 1.57 (40) 2 (50.80) 1.57 (40) 10.5 (267) 0.75 (19) 6.30 (160) Dimensions in inches (mm) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 19 High Current Single Line Feed-thru Filters High current single line feed-thru filters from Spectrum Control are ideal to meet broad frequency applications. This series filters EMI/RFI with 150-500 Amp current with AC and DC voltages. These filters are ideal for cellular base stations, telephone switching stations and high voltage power supply applications. Single Line Filters Features ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Ideal for high current applications Excellent filtering in a compact, durable package Bolt-in style for easy installation Current ratings to 500 Amps Voltage ratings up to 1000VDC and 240VAC Available with single, dual, and triple feed-thrus Various capacitance ratings (up to 1.68 µF) Rugged construction for indoor and outdoor applications Various mounting brackets available Low cost EMI solution Design flexibility Custom mechanical configurations available ■ ■ 20 Temperature Range: Amps Amps Amps Amps Amps Amps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 12 12 14 16 18 mm mm mm mm mm mm -25°C to 85°C Typical Insertion Loss (dB) 90 80 70 50 Telecommunications (cellular base stations, telephone switching racks, etc.) Power supplies Servers Part Number Current Ratings/Bolt Size: 150 200 250 300 400 500 60 Applications ■ Electrical Specifications 1.68µF 40 0.04µF 30 0.03µF 0.02µF 20 0.01µF 10 0 0.01 0.1 1 10 Frequency (MHz) 100 Figure Voltage Rating @ -40C to +85C Current Rating Capacitance Value 52-226-001 A 50VDC Max. 300 Amps 0.02 µF min. @ 50VDC 52-226-002 B 50VDC Max. 300 Amps 0.02 µF min. @ 50VDC 52-226-006 C 50VDC Max. 150 Amps 0.02 µF min. @ 50VDC 52-226-008 D 75VDC Max. 200 Amps 0.02 µF min. @ 50VDC 52-226-009 E 50VDC Max. 150 Amps 0.02 µF min. @ 50VDC 52-267-008 F 200VDC Max. 200 Amps 0.02 µF min. @ 40VDC 52-226-004 F 200VDC Max./240 VAC 200 Amps 1.68 µF min. @ 50VDC 52-226-015 G 200VDC Max./240 VAC 200 Amps 1.68 uF min. @ 50VDC 52-267-002 H 200VDC Max./240 VAC 200 Amps 1.68 µF min. @ 40VDC 52-267-003 J 200VDC Max./240 VAC 200 Amps 1.68 µF min. @ 40VDC 52-267-009 F 200VDC Max./240 VAC 60 Amps 1.68 µF min. @ 50VDC 52-267-010 K 200VDC Max./240 VAC 250 Amps 1.68 µF min. @ 40VDC 52-267-011 K 200VDC Max./240 VAC 100 Amps 1.68 µF min. @ 40VDC 52-267-012 K 250VDC Max. 100 Amps 1.00 µF+20% @ 40VDC 1000 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 High Current Single Line Feed-thru Filters Mechanical Dimensions Figure A Figure B 4.67 (118.6) 4.20 (106.6) .314 (8.0) (2x) 4.669 (118.6) .236 (6.0) (2x) 4.196 (106.6) .236 (6.0) (2x) .314 (8.0) (2x) 1.221 (31.0) 1.220 (31.0) 1.811 (46.0) 1.498 (38.0) 1.811 (46.0) 2.441 (62.0) Ø .204 ± .005 THRU (4x) (5.2 ± .13) 1.587 (40.3) 1.496 (38.0) 1.586 (40.3) Single Line Filters 2.441 (62.0) Ø .204 (5.2) THRU (4x) SCI 24-0058-4800 SCI 24-0058-4800 M14 x 2.0 - 6g STUD (2x) 1.295 ± .02 (2x) (32.9 ± 0.6) M14 x 2.0-6g STUD (2x) 1.295 ± .02 (32.9 ± 0.6) (2x) SCI 22-0833-0100 BRACKET ASSEMBLY 2.047 ± .02 (52.0 ± 0.6) 2.598 (66.0) MAX. 4.015 ± .02 (102.0 ± 0.6) .276 ± .016 (7 ± .4) .063 (1.6) .063 (1.6) 2.598 (66.0) MAX. 4.015 ± .02 (102.0 ± 0.6) SCI 24-0058-4800 .125 (3.18) TYP. FOR LABEL LOCATION .125 (3.18) TYP. FOR LABEL LOCATION DATE CODE DATE CODE .826 (21.0) MIN. THRD. LENGTH Ø1.50 (38.8) SCI 24-0058-4700 (3x) 45˚ CHAMFER BOTH ENDS .826 (21.0) MIN. THRD. LENGTH Figure C Ø 1.25 (31.75) Figure D Ø .874 (22.20) (2x) Ø .874 (22.20) (2x) 5.393 (137.0) 5.039 (128.0) .177 (4.5) (2x) .826 (21.0) 1.299 (33.0) 5.393 (137.0) 5.039 (128.0) .177 (4.5) (2x) .177 (4.5) (2x) .177 (4.5) (2x) .826 (21.0) 1.299 (33.0) 1.652 (42.0) 1.652 (42.0) 1.984 (49.5) 1.496 (38.0) Ø .204 ± .005 (5.2 ± .13) THRU .807 (20.5) 2.0 .429 (10.9) 1.413 ± .002 (35.9 ± 0.6) 2.598 (66.0) MAX. Ø .204 ± .005 (5.2 ± .13) THRU (4x) Ø .118 ± .005 (3.0 ± .13) Ø .118 ± .005 (3.0 ± .13) M10 x 1.5-6g STUD-BRASS (UNPLATED) M10 x 1.5-6g STUD TIN PLATED BRASS .248 (6.3) (2x) 1.295 ± .02 (32.9 ± 0.6) (2x) 1.496 (38.0) .807 (20.5) 1.984 (49.5) M10 x 1.5-6g STUD TIN PLATED BRASS 1.295 ± .02 (32.9 ± 0.6) (2x) .248 [6.3] (2x) .063 (1.6) .429 [10.9] 1.421 ± .012 [36.1 ± 0.3] 1.89 0± .02 (48.0 ± 0.6) MAX. 4.015 ± .02 (102.0 ± 0.6) 2.717 ± .02 (89.0 ± .6) .063 (1.6) 7.0 MIN. .826 (21.0) MIN. .826 (21.0) MIN. DATE CODE DATE CODE M10 x 1.5-6g STUD-BRASS (UNPLATED) Figure E Ø 1.25 (31.75) M10 x 1.5-6g STUD TIN PLATED BRASS Ø 1.25 (31.75) Figure F Ø .874 (22.20) (2x) 5.393 (137.0) 5.039 (128.0) .177 (4.5) (2x) 3.406 (86.5) .177 (4.5) (2x) 0.197 (5.00) .826 (21.0) 1.299 (33.0) 3.799 (96.5) 0.197 (5.00) 1.801 (45.75) 0.197 (5.00) 1.652 (42.0) 1.984 (49.5) 1.496 (38.0) .807 (20.5) 1.295 ± .02 (32.9 ± 0.6) (2x) Ø .118 ± .005 (3.0 ± .13) Ø .204 ± .005 (5.2 ± .13) THRU (4x) (6x) ø 0.185 ±0.004 (4.70 ±0.1) (2x) ø1.378 ± 0.004 (MAX) (35.0 ±0.1) M10 x 1.5-6g STUD TIN PLATED BRASS 0.689 (17.5) 1.909 ±0.02 (48.5 ±0.5) 1.378 (35.0) 1.772 (45.0) 1.053 ±0.01 (26.75 ±0.3) M10x1.5 – 6g STUDS 1.102 ±0.02 (28.0 ± .5) .063 (1.6) 2.598 (66.0) MAX. .961 ±0.02 (24.4 ±0.5) 4.015 ± .02 (102.0 ± .6) 3.976 ±0.02 (101.0 ±0.5) .921 (23.4) .047 (1.2) SQ 52 - 226 - 004 200VDC 200A XXXX 1.890 (48.0) 1.969 ±0.02 (50.0 ±0.5) .826 (21.0) MIN. Ø 1.25 (31.75) Dimensions in inches (mm) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 21 High Current Single Line Feed-thru Filters Figure G Figure H 3.956 (100.5) 1.702 (43.25) 3.405 (86.5) 1.506 (38.25) Ø 1.378 (35.0) 2.955 (75.0) 1.378 (35.0) .964 (25.4) Single Line Filters 1.023 (26.0) 1.929 (49.0) 5.516 (140.0) PEM CLS-M4-1 (6 PLACES) 1.909 ± 1.968 (48.5 ± 50) 2.726 (69.2) 1.363 (34.6) 1.259 (32.0) .078 (2.0) MAX. 2.092 (53.10) 1.382 (35.08) 5.520 (140.10) .248 (6.3) 1.889 (48.0) 1.52 (.060) 1.777 (45.10) 3.428 (87.00) 2.719 (69.00) RED BLACK 7.480 + .787/-0 (190.0 + 20.0/-0) 8.858 + .787/-0 (225.0 + 20.0/-0) 10.433 + .78/-0 (265.0 + 20.0/-0) .984 (25.0) M10 x 1.5-6g STUD Figure J Figure K 3.799 (96.5) 4.807 (122.00) 3.406 (86.50) 1.801 (15.75) 2.403 (51.00) Ø .283 (7.2) (2x) 2.955 (75.0) 0.197 (5.0) 0.197 (5.0) 0.689 (17.5) PEM BSOS-M4-6 (6x) 1.378 (35.00) ø 0.185±0.004 (6x) (4.70±0.1) 2.285 (58.00) .197 (5.0) 4.570 (116.00) (MAX) ø 1.378±0.004 (2x) (35.0±0.1) 5.516 (140.0) 2.726 (69.20) 1.772 (45.0) 1.909±0.02 (48.5±0.5) 1.053±0.01 (26.75±0.3) 1.363 (34.60) 0.610±0.02 (15.5±0.5) 2.092 (53.10) 1.382 (35.08) 5.520 (140.10) 1.777 (45.10) 3.428 (87.00) 2.719 (69.00) .080 (1.52) .047 (1.2) 0.118±0.02 (3±0.5) 3.19±0.16 (81.0±4) .039 (1.00) 1.890 (48.0) 1.969±0.02 (50.0±0.5) M10 x 1.5-6g STUD Dimensions in inches (mm) 22 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 High Current Filtered Terminal Blocks Features ■ ■ ■ Ideal for high current applications Design flexibility Available in 2 x 2 thru 2 x 6 positions UL approved Specifications Applications ELECTRICAL Voltage rating: Capacitance: Telecommunications switching networks ■ Cellular base stations ■ Power supplies ■ UPS ■ Instrumentation ■ High reliability radar and transmission systems ■ Industrial controls ■ Power distribution ■ 4.600 (116.8) Dielectric withstanding voltage: 1000VDC for 1 minute Current rating: 60 Amps max per terminal Typical Insertion Loss — dB: In 50 Ohm Circuit 1 5 10 50 8-32 THREADED INSERTS (4X) 1.625 (41.3) .65 MIN (16.5) (6X) 1.10 (27.9) .80 MIN (20.3) .75 (19.0) (5X) .172 (4.3) (4X) 70 100 160 200 MHz......... 36 MHz......... 33 MHz......... 25 MHz......... 25 US .200: (5.08 mm) AWG #12-26 steel, zinc chromate plate .05" (1.30 mm) contact hole UL rated 94VO polyamide 2.5 in.-lbs. max. (28 Ncm) Brass, tin-plated * For filter elements with additional capacitance values, consult factory. 1.685 2.025 (42.8) (51.4) 2.625 2.025 .75 (19.0) (66.7) (51.4) PANEL CUTOUT 4.6 (116.8) 5.0 (127) 5.0 (127) 5.6 (142.2) Part Number MHz....... 8 MHz....... 24 MHz....... 32 MHz....... 38 MECHANICAL Center spacing: Wire size: Screw material: Recommended PCB hole diameter: Molded material: Tightening torque: Terminal: R.125 (3.2) (4X) 1.15 (29.1) 100 VDC per terminal .015µF* +80% / -20% per cap .030µF +80% / -20% per pair Filtered Terminal Blocks ■ Number of Terminals in. A (mm) in. B (mm) in. C (mm) 52-1013-102 2x2 2.60 66.04 2.00 50.80 1.66 42.16 52-1013-103 2x3 3.35 85.09 2.75 69.85 2.41 61.21 52-1013-104 2x4 4.10 104.14 3.50 88.90 3.16 80.25 52-1013-105 2x5 4.85 123.19 4.25 107.95 3.91 99.31 52-1013-106 2x6 5.60 142.24 5.00 127.00 4.66 118.36 Dimensions in inches (mm) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-835-1650 • Fax: 814-835-1651 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 23 Power Entry Modules Bolt-in Rear Terminals 60-BPR & BPS Series Features Power Entry Modules ■ ■ ■ ■ ■ ■ ■ Tested and found to be IAW VDE 0565 Part 3. Ideally suited for products that must conform to FCC part 15 regulations Metal case offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards Solder lug and Fast-on tab terminals available Operating temperature: -25°C to +85°C (including temperature rise, see graph on page 25) UL approved low leakage version also available Circuit Diagram 3 1 Applications ■ ■ ■ ■ CY L1 CX E E Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units CY 2 4 Specifications Model* Rated Voltage (@ 50/60Hz) Rated Current 60-XXX-010-3-2 60-XXX-010-3-4 250VAC Leakage Current (Max.) CY Capacitance 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 60-XXX-010-5-4 0.35mA 250VAC 2200pF ± 20% 0.50mA 3300pF ± 20% 60-XXX-020-5-4 0.35mA 250VAC 2200pF ± 20% 0.50mA 3300pF ± 20% 60-XXX-030-5-4 0.35mA 250VAC 2200pF ± 20% 0.50mA 3300pF ± 20% 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 0.35mA 2200pF ± 20% 60-XXX-060-5-4 0.53mH 45°C .022uF ± 20% 0.26mH 45°C .01uF ± 20% 0.15mH 45°C .022uF ± 20% .022uF ± 20% .047uF ± 20% 250VAC 10A 250VAC 15A Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 45g Input: Compatible with IEC-320 24 30°C .022uF ± 20% .047uF ± 20% 6A 60-XXX-060-5-2 60-BPR-150-3-11 1.2mH .022uF ± 20% .047uF ± 20% 60-XXX-060-3-2 60-XXX-100-5-2 30°C .022uF ± 20% .047uF ± 20% 3A 60-XXX-030-5-2 60-XXX-100-3-2 2.4mH .022uF ± 20% .047uF ± 20% 60-XXX-030-3-2 60-XXX-060-3-4 30°C .022uF ± 20% .047uF ± 20% 2A 60-XXX-020-5-2 60-XXX-030-3-4 6.0mH .022uF ± 20% .047uF ± 20% 60-XXX-020-3-2 60-XXX-020-3-4 Temperature Rise (Max.) .047uF ± 20% 1A 60-XXX-010-5-2 Inductance (L1) CX * Substitute BPR or BPS for XXX BPS - Solder lug terminals BPR - Fast-on tab terminals SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Power Entry Modules Bolt-in Rear Terminals 60-BPR & BPS Series Temperature Characteristics 0.807 (20.5) Power Entry Modules 120 Current (%) 100 .944 (24) 80 .846 (21.5) 60 1.476 (37.5) (2x) .142 (3.6) 40 1.967 (50) 0 20 30 40 50 60 70 Ambient Temperature (°C) 80 .157 (4) 1.10 (28) 1.181 (30) 1.573 (40) 20 * General tolerance ± .012 (0.3) 90 Dimensions in inches (mm) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 50Ω 80 70 70 60-BPX-010-5-X 60-BPX-010-5-X Insertion Loss (dB) 60 50 40 60-BPX-020-5-X 30 60-BPX-030-5-X 20 60 50 40 60-BPX-020-5-X 30 60-BPX-030-5-X 20 10 10 0 0.1 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 5 10 20 50 60-BPX-060;-100 60-BPX-060;-100 80 80 70 70 Insertion Loss (dB) 60 60-BPX-060-5-X 50 40 30 60-BPX-100-5-X 20 60-BPX-060-X-4 60 50 60-BPX-060-X-2 40 60-BPX-100-X-2 30 20 10 10 0 0.1 2 Frequency (MHz) Frequency (MHz) Insertion Loss (dB) 50Ω Level Meter 50Ω 60-BPX-010;-020;-030 60-BPX-010;-020;-030 80 Insertion Loss (dB) 2.263 (57.5) .252 (6.4) 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 25 Power Entry Modules Bolt-in Right Angle Terminals 60-BPF Series Features Power Entry Modules ■ ■ ■ ■ ■ ■ ■ ■ Tested and found to be IAW VDE 0565 Part 3. Ideally suited for products that must conform to FCC part 15 regulations Metal case offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards PCB mounting types available (see page 54) Length under tab is shortened for small spaces Operating temperature: -25°C to +85°C (including temperature rise, see graph on page 27) UL approved low leakage version also available ■ ■ ■ 3 1 CY L1 CX Applications ■ Circuit Diagram E E CY Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units 2 4 Specifications Model Rated Voltage (@ 50/60Hz) Rated Current 60-BPF-010-3-2 60-BPF-010-3-4 250VAC Leakage Current (Max.) CY Capacitance 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 60-BPF-010-5-4 0.35mA 250VAC 2200pF ± 20% 0.50mA 3300pF ± 20% 60-BPF-020-5-4 30°C 2.4mH 30°C 1.2mH 30°C 0.53mH 45°C .022uF ± 20% .022uF ± 20% .047uF ± 20% 60-BPF-030-3-2 0.35mA 250VAC 2200pF ± 20% .022uF ± 20% .047uF ± 20% 3A 60-BPF-030-5-2 0.50mA 3300pF ± 20% 60-BPF-030-5-4 .022uF ± 20% .047uF ± 20% 60-BPF-060-3-2 60-BPF-060-3-4 6.0mH .022uF ± 20% .047uF ± 20% 2A 60-BPF-020-5-2 60-BPF-030-3-4 Temperature Rise (Max.) .047uF ± 20% 60-BPF-020-3-2 60-BPF-020-3-4 Inductance (L1) .022uF ± 20% .047uF ± 20% 1A 60-BPF-010-5-2 CX 0.35mA 250VAC 2200pF ± 20% .047uF ± 20% 6A 60-BPF-060-5-2 60-BPF-060-5-4 .022uF ± 20% 0.50mA 3300pF ± 20% .022uF ± 20% .047uF ± 20% Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 50g Input: Compatible with IEC-320 26 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Power Entry Modules Bolt-in Right Angle Terminals 60-BPF Series ( ) 1.463 (37.2) 1.967 (50) Temperature Characteristics 120 1.317 (33.5) 1.573 (40) .885 (22.5) .991 (25.2) .590 (15) 2- .142 (3.6) Current (%) 100 .047 (1.2) .232 (5.9) 80 .024 (.6) 5 . R4 .865 (22) 60 2- .142 (3.6) 1.573 (40) 40 .142 .059 (3.6) (1.5) .031 (.8) 1.070 (27.2) 1.180 (30) * General tolerance ± .012 (.3) .779 1.180 (19.8) (30) .708 (18) Panel cutout dimensions mounts from backside 20 0 20 30 40 50 60 70 Ambient Temperature (°C) 80 Power Entry Modules 60-BPF Fast-on Terminals 90 Dimensions in inches (mm) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 60-BPF-010;-020 80 70 70 Insertion Loss (dB) Insertion Loss (dB) 60-BPF-010-3-X 60 50 60-BPF-020-3-X 40 30 20 10 60 60-BPF-010-X-4 50 40 30 60-BPF-020-X-4 20 10 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 Frequency (MHz) 5 10 20 50 20 50 60-BPF-030;-060 60-BPF-030;-060 80 70 70 60 Insertion Loss (dB) Insertion Loss (dB) 2 Frequency (MHz) 80 60-BPF-030-3-X 50 40 60-BPF-060-3-X 30 20 60 50 40 60-BPF-030-X-4 30 60-BPF-060-X-4 20 10 10 0 0.1 50Ω Level Meter 50Ω 60-BPF-010;-020 80 0 0.1 50Ω 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 Frequency (MHz) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 27 Power Entry Modules High Frequency Attenuation 60-BHS Series Features Power Entry Modules ■ ■ ■ ■ ■ ■ ■ ■ Tested and found to be IAW VDE 0565 Part 3. Ideally suited for products that must conform to FCC part 15 regulations Metal cased miniature filter offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 PCB mounting types available (see page 56) PCB mounting minimizes space and provides economical installation Excellent filtering characteristics for high frequencies Earth coil standard Operating temperature: -25°C to +85°C (including temperature rise, see graph on page 29) Applications ■ ■ ■ ■ Circuit Diagram 3 1 CY L1 CX E E Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units CY 2 4 L2 Specifications Model Rated Voltage (@ 50/60Hz) Rated Current 60-BHS-010-3-11 60-BHS-010-3-4 250VAC Leakage Current (Max.) CY Capacitance 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 60-BHS-010-5-4 0.35mA 250VAC 2200pF ± 20% 0.50mA 3300pF ± 20% 60-BHS-020-5-4 18.3uH 30°C 2.4mH 18.3uH 30°C 1.2mH 18.3uH 30°C .53mH 18.3uH 45°C 0.1uF ± 20% 0.1uF ± 20% .047uF ± 20% 60-BHS-030-3-11 0.35mA 250VAC 2200pF ± 20% 0.1uF ± 20% .047uF ± 20% 3A 60-BHS-030-5-11 0.50mA 3300pF ± 20% 60-BHS-030-5-4 0.1uF ± 20% .047uF ± 20% 60-BHS-060-3-11 60-BHS-060-3-4 6mH 0.1uF ± 20% .047uF ± 20% 2A 60-BHS-020-5-11 60-BHS-030-3-4 Temperature Rise (Max.) .047uF ± 20% 60-BHS-020-3-11 60-BHS-020-3-4 Inductance (L1) (L2) 0.1uF ± 20% .047uF ± 20% 1A 60-BHS-010-5-11 CX 0.35mA 250VAC 2200pF ± 20% 6A 60-BHS-060-5-11 60-BHS-060-5-4 0.1uF ± 20% .047uF ± 20% 0.50mA 3300pF ± 20% 0.1uF ± 20% .047uF ± 20% Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 50g Input: Compatible with IEC-320 28 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Power Entry Modules High Frequency Attenuation 60-BHS Series .098 (2.5) 1.967 (50) 1.573 (40) 120 .885 (22.5) 100 Current (%) 1.534 (39) 1.389 (35.3) Power Entry Modules Temperature Characteristics 1.180 (30) 2- .142 (3.6) 80 1.180 (30) .031 (.8) .5 R4 .865 (22) 60 40 2- .142 (3.6) 1.573 (40) .779 1.180 (19.8) (30) Panel cutout dimensions mounts from backside 20 0 20 30 40 50 60 70 Ambient Temperature (°C) 80 Dimensions in inches (mm) 90 Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 90 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 60-BHS-XXX-X-11 90 50Ω 50Ω Level Meter 50Ω 60-BHS-XXX-3-11 80 80 Insertion Loss (dB) Insertion Loss (dB) 60-BHS-010-X-11 70 60-BHS-020-X-11 60 50 40 60-BHS-030-X-11 30 60-BHS-060-X-11 70 60-BHS-010-3-11 60 50 60-BHS-020-3-11 40 60-BHS-030-3-11 30 60-BHS-060-3-11 20 20 10 10 0 0.1 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 90 60-BHS-XXX-X-4 90 5 10 20 50 60-BHS-XXX-3-4 80 60-BHS-010-X-4 70 Insertion Loss (dB) Insertion Loss (dB) 80 60-BHS-020-X-4 60 50 40 60-BHS-030-X-4 30 60-BHS-060-X-4 70 60-BHS-010-3-4 60 50 60-BHS-020-3-4 40 60-BHS-030-3-4 30 60-BHS-060-3-4 20 20 10 10 0 0.1 2 Frequency (MHz) Frequency (MHz) 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 29 Power Entry Modules Bolt-in Rear Terminals For General Purpose Applications 10-BPF Series Features Power Entry Modules ■ ■ ■ ■ ■ ■ Ideally suited for products that must conform to FCC part 15 regulations Metal case offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards Operating temperature: -25°C to +70°C Compact configuration Circuit Diagram CX CY Applications ■ ■ ■ ■ CY L1 1 Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units CX CY L1 CX CY 2 CX CX L1 CY CY 3 Specifications Model Rated Rated Voltage Current (@ 50/60Hz) 10-BPF-001-5-A Leakage Current (Max.) 1A 120/250VAC 1.5mH 0.50mA 10-BPF-006-5-A 6A 4700pF 10A 10-BPF-010-5-D Temperature Rise (Max.) C A C 2 B A 0.5mH 1 3300pF & 0.01uF 1.5mH 2 B 3300pF 0.01uF 0.5mH 1 A 3300pF & 0.01uF 3300pF & 0.01uF 1.5mH 3 B 3300pF 3300pF & 0.01uF 10-BPF-006-5-D 0.01uF Figure A 3.0mH 1 3A 10-BPF-003-5-C 10-BPF-010-5-A Inductance Circuit (L1) Diagram 3300pF 10-BPF-003-5-A 10-BPF-006-5-C CX 2200pF 10-BPF-001-5-C 10-BPF-003-5-D Capacitance CY 30°C C Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 45g Input: Compatible with IEC-320 30 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Power Entry Modules Bolt-in Rear Terminals Figure B M3 (2X) For General Purpose Applications 1.6 (40) M3 (2X) 2.0 (52) 2.0 (52) 1.1 (28.5) +.01 -0.0 1.6 (40) ±.007 1.4 (37) 2.8 (72) 1.25 (32) Figure A Figure C .80 (20.5) +.01 -0.0 1.4 (3.5) (2X) 2.3 (62) 1.9 1.6 1.2 (50) (40) (30) .62 (16) .82 (21) .25 (6.5) 1.8 (46) .13 (3.5 (2X) 1.1 (28) 1.5 (37.5) 1.6 (40) 2.0 (51) 1.9 (50) 1.1 (27) Power Entry Modules 10-BPF Series .07 (2) Dimensions in inches (mm) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 80 70 70 Insertion Loss (dB) Insertion Loss (dB) 10-BPF-001-5-A 10-BPF-001-5-C 50 40 10-BPF-003-5-A 30 10-BPF-003-5-C 20 60 10-BPF-001-5-A 50 10-BPF-001-5-C 40 30 10-BPF-003-5-A 20 10-BPF-003-5-C 10 10 0 0.1 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 5 10 50 80 10-BPF-006-5-D 70 70 Insertion Loss (dB) 60 10-BPF-006-5-A 10-BPF-006-5-C 40 30 20 10-BPF-006-5-D 60 50 40 10-BPF-010-5-A 10-BPF-010-5-D 30 10-BPF-006-5-A 20 10-BPF-006-5-C 10-BPF-010-5-A 10 10 0 0.1 20 10-BPF-006;-010 10-BPF-006;-010 80 Insertion Loss (dB) 2 Frequency (MHz) Frequency (MHz) 50 50Ω Level Meter 50Ω 10-BPF-001;-003 10-BPF-001;-003 80 60 50Ω 10-BPF-010-5-D 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 31 Power Entry Modules Bolt-in Rear Terminals For Medical Purpose Applications 10-BPF Series Features Power Entry Modules ■ ■ ■ ■ ■ ■ ■ Ideally suited for products that must conform to FCC part 15 regulations Metal case offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards Operating temperature: -25°C to +70°C Compact configuration Low leakage current Circuit Diagram ■ ■ ■ ■ 3 1 Applications L1 Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units CX E E 2 4 Specifications Model Rated Rated Voltage Current (@ 50/60Hz) 10-BPF-001-2-A 10-BPF-003-2-A 120/250VAC 10-BPF-006-2-A 1A Leakage Current (Max.) Capacitance CX 5uA 0.01uF Inductance (L1) Circuit Diagram Figure Temperature Rise (Max.) 1 A 30°C 3.0mH 10A 1.5mH 0.5mH Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 45g Input: Compatible with IEC-320 32 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Power Entry Modules Bolt-in Rear Terminals For Medical Purpose Applications Power Entry Modules 10-BPF Series M3 (2X) 1.1 (28.5) +.01 -0.0 1.6 (40) ±.007 .80 (20.5) +.01 -0.0 1.4 (3.5) (2X) 0.807 (20.5) 1.9 1.6 1.2 (50) (40) (30) Dimensions in inches (mm) 1.1 (28) 1.5 (37.5) .63 (16) Common Mode Normal Mode 1 3 Filter 2 4 1 3 Filter 2 4 Oscillator 50Ω 50Ω Level Meter 50Ω Oscillator 50Ω 50Ω 50Ω Level Meter 50Ω 10-BPF-001;-003;-006 80 70 70 Insertion Loss (dB) Insertion Loss (dB) 10-BPF-001;-003;-006 80 60 2.0 (51) .25 (6.5) .82 (21) 10-BPF-001-2-A 50 10-BPF-003-2-A 40 30 20 60 50 40 30 10-BPF-006-2-A 10-BPF-001-2-A 20 10-BPF-006-2-A 10 0 0.1 10 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 10-BPF-003-2-A 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 33 Power Entry Modules Snap-in with Wire Leads 60-SPL Series Features Power Entry Modules ■ ■ ■ ■ ■ ■ ■ Tested and found to be IAW VDE 0565 Part 3. Ideally suited for products that must conform to FCC part 15 regulations Metal cased miniature filter offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards Snap-in style saves labor and hardware inventory Wire output minimizes space and provides economical installation Operating temperature: -25°C to +85°C (including temperature rise, see graph on page 35) Applications ■ ■ ■ ■ Circuit Diagram 3 1 CY L1 CX E E Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units CY 2 4 Specifications Model Rated Voltage (@ 50/60Hz) Rated Current 60-SPL-010-3-2 60-SPL-010-3-3 250VAC Leakage Current (Max.) CY Capacitance 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 60-SPL-010-5-3 0.35mA 250VAC 2200pF ± 20% 0.50mA 3300pF ± 20% 60-SPL-020-5-3 30°C 2.4mH 30°C 1.2mH 30°C 0.53mH 45°C 22nF ± 20% 22nF ± 20% 33nF ± 20% 60-SPL-030-3-2 0.35mA 250VAC 2200pF ± 20% .022uF ± 20% 3300pF ± 20% 3A 60-SPL-030-5-2 0.50mA 60-SPL-030-5-3 2200pF ± 20% .033uF ± 20% 3300pF ± 20% 60-SPL-060-3-2 60-SPL-060-3-3 6.0mH 22nF ± 20% 33nF ± 20% 2A 60-SPL-020-5-2 60-SPL-030-3-3 Temperature Rise (Max.) 33nF ± 20% 60-SPL-020-3-2 60-SPL-020-3-3 Inductance (L1) 22nF ± 20% 33nF ± 20% 1A 60-SPL-010-5-2 CX 0.35mA 250VAC 2200pF ± 20% 6A 60-SPL-060-5-2 60-SPL-060-5-3 22nF ± 20% 33nF ± 20% 0.50mA 3300pF ± 20% 22nF ± 20% 33nF ± 20% Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 50g Input: Compatible with IEC-320 34 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Power Entry Modules Snap-in with Wire Leads 60-SPL Series .963 (24.5) * General tolerance ± .012 (.3) 120 .853 (21.7) .838 (21.3) Panel cutout dimensions 100 Current (%) R2 * Metal case Tin Plated 80 W T W .039 (1.0) 1.270 (32.3) .047 (1.2) 1.274 (32.4) .059 (1.5) 1.285 (32.5) T :Panel Thickness 1.612 (41) 4.719 (120)* .252 (6.4) 1.172 (29.8) .236 (6) 60 Blue UL 1015 AWG #18 1.397 (35.5) 40 Green/Yellow Brown 20 PVC Insulated wire * Custom lengths available upon request. 0 20 30 40 50 60 70 Ambient Temperature (°C) 80 Dimensions in inches (mm) Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 60-SPL-010-X-4 60-SPL-020-5-X 70 60-SPL-010-X-2 Insertion Loss (dB) 60-SPL-010-5-X 50 60-SPL-010-3-X 40 30 20 60 50 60-SPL-020-X-4 40 30 60-SPL-020-X-2 20 10 10 0 0.1 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 5 10 20 50 60-SPL-030;-060 60-SPL-030;-060 80 80 60-SPL-030-X-4 60-SPL-030-5-X 70 70 60-SPL-030-3-X Insertion Loss (dB) 60 50 40 60-SPL-060-5-X 30 60-SPL-060-3-X 60 60-SPL-030-X-2 50 40 60-SPL-060-X-4 30 20 20 10 10 0 0.1 2 Frequency (MHz) Frequency (MHz) Insertion Loss (dB) 50Ω Level Meter 50Ω 80 60-SPL-020-3-X Insertion Loss (dB) 50Ω 60-SPL-010;-020 60-SPL-010;-020 80 70 UL1617 AWG #22 90 Common Mode 60 Power Entry Modules Temperature Characteristics 60-SPL-060-X-2 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 35 Power Entry Modules Bolt-in with Wire Leads 60-BPL Series Features Ideally suited for products that must conform to FCC part 15 regulations Metal case filter offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards Wire output for minimizing space use and economical installation Operating temperature: -25°C to +85°C (including temperature rise, see graph on page 37) ■ Power Entry Modules Tested and found to be IAW VDE 0565 Part 3. ■ ■ ■ ■ ■ Circuit Diagram 3 1 Applications ■ ■ ■ ■ CY L1 CX E E Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units CY 2 4 Specifications Model Rated Voltage (@ 50/60Hz) Rated Current 60-BPL-010-3-2 60-BPL-010-3-3 250VAC Leakage Current (Max.) CY Capacitance 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 60-BPL-010-5-3 0.35mA 250VAC 2200pF ± 20% 0.50mA 3300pF ± 20% 60-BPL-020-5-3 30°C 2.4mH 30°C 1.2mH 30°C 0.53mH 45°C 22nF ± 20% 22nF ± 20% 33nF ± 20% 60-BPL-030-3-2 0.35mA 250VAC 2200pF ± 20% .022uF ± 20% 3300pF ± 20% 3A 60-BPL-030-5-2 0.50mA 60-BPL-030-5-3 2200pF ± 20% .033uF ± 20% 3300pF ± 20% 60-BPL-060-3-2 60-BPL-060-3-3 6.0mH 22nF ± 20% 33nF ± 20% 2A 60-BPL-020-5-2 60-BPL-030-3-3 Temperature Rise (Max.) 33nF ± 20% 60-BPL-020-3-2 60-BPL-020-3-3 Inductance (L1) 22nF ± 20% 33nF ± 20% 1A 60-BPL-010-5-2 CX 0.35mA 250VAC 2200pF ± 20% 33nF ± 20% 6A 60-BPL-060-5-2 60-BPL-060-5-3 22nF ± 20% 0.50mA 3300pF ± 20% 22nF ± 20% 33nF ± 20% Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 50g Input: Compatible with IEC-320 36 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Power Entry Modules Bolt-in with Wire Leads 60-BPL Series .5 .5 R4 .865 (22) 120 1.180 (30) 1.573 (40) Current (%) 100 1.573 (40) 1.612 (41) .830 (21.1) 1.172 (29.8) 1.967 (50) 20 30 40 50 60 70 Ambient Temperature (°C) 80 GREEN/YELLOW BROWN 90 Dimensions in inches (mm) Normal Mode 1 3 Filter 2 4 1 3 Filter 2 4 Oscillator 50Ω 50Ω Level Meter 50Ω Oscillator 50Ω 50Ω 50Ω Level Meter 50Ω 60-BPL-010;-020 60-BPL-010;-020 80 80 60-BPL-020-5-X 60-BPL-010-X-4 70 70 60-BPL-010-X-2 60 50 60-BPL-010-5-X 40 60-BPL-010-3-X 30 20 Insertion Loss (dB) 60-BPL-020-3-X 60 50 60-BPL-020-X-4 40 30 60-BPL-020-X-2 20 10 10 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) Frequency (MHz) 60-BPL-030;-060 60-BPL-030;-060 80 80 60-BPL-030-X-4 60-BPL-030-5-X 70 70 60-BPL-030-3-X Insertion Loss (dB) 60 50 40 60-BPL-060-5-X 30 60-BPL-060-3-X 20 60 60-BPL-030-X-2 50 40 60-BPL-060-X-2 30 20 60-BPL-060-X-4 10 10 0 0.1 * General tolerance ±.012 (0.3) PVC Insulated wire UL1617 AWG #22 * Custom lengths available upon request. Common Mode 0 0.1 .236 (6) UL1015 AWG # 18 BLUE 1.160 (29.5) 1.573 (40) 0 Insertion Loss (dB) 4.719 (120)* .252 (6.4) 60 40 1.239 (31.5) Panel cutout dimensions mounts from front side .944 (24) 2- .142 (3.6) 20 Insertion Loss (dB) 2- .118 (M3) 2- .130 (3.3) Panel cutout dimensions mounts from back side 80 R3 .885 (22.5) .837 (21.3) Power Entry Modules Temperature Characteristics 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 37 Power Entry Modules Bolt-in with Wire Leads 10-BPL Series Features Ideally suited for products that must conform to FCC part 15 regulations Metal case filter offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards Wire output for minimizing space use and economical installation Operating temperature: -25°C to +70°C Compact configuration Power Entry Modules ■ ■ ■ ■ ■ ■ ■ Circuit Diagram Applications ■ ■ ■ ■ 3 1 CY L1 CX E E Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units CY 2 4 Specifications Model Rated Rated Leakage Voltage Current Current (@ 50/60Hz) (Max.) 10-BPL-006-5-B CX 3300pF 0.01uF 1A 10-BPL-001-5-B 10-BPL-003-5-B Capacitance CY 250VAC 3A Inductance Circuit Diagram (L1) Figure Temperature Rise (Max.) A 30°C 3.0mH 0.50mA 6A 1.5mH 1 0.5mH Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 50g Input: Compatible with IEC-320 38 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Power Entry Modules Bolt-in with Wire Leads 10-BPL Series Figure A Power Entry Modules M3 (2X) 1.1 (28.5) +.01 -0.0 1.6 (40) ±.007 .80 (20.5) +.01 -0.0 1.4 (3.5) (2X) 1.9 1.6 1.2 (50) (40) (30) 1.1 (28) 1.5 (37.5) .63 (16) 2.0 (51) .25 (6.5) .82 (21) Dimensions in inches (mm) Common Mode Normal Mode 1 3 Filter 2 4 1 3 Filter 2 4 Oscillator 50Ω 50Ω Level Meter 50Ω Oscillator 50Ω 80 10-BPL-001-5-B 70 70 10-BPL-003-5-B 10-BPL-001-5-B Insertion Loss (dB) Insertion Loss (dB) 50Ω Level Meter 50Ω 10-BPL-001;-003;-006 10-BPL-001;-003;-006 80 60 50Ω 50 40 30 10-BPL-006-5-B 20 60 50 40 10-BPL-003-5-B 30 20 10-BPL-006-5-B 10 10 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 39 Power Entry Modules Snap-in Mount 60-SPR & SPS Series Features Power Entry Modules ■ ■ ■ ■ ■ ■ ■ ■ Tested and found to be IAW VDE 0565 Part 3. Ideally suited for products that must conform to FCC part 15 regulations Metal cased miniature filter offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards Snap-in style saves labor and hardware inventory Solder lug and fast-on tab terminations available Operating temperature: -25°C to +85°C (including temperature rise, see graph on page 41) UL approved low leakage version also available ■ ■ ■ 3 1 CY L1 CX Applications ■ Circuit Diagram E E CY Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units 2 4 Specifications Model* Rated Voltage (@ 50/60Hz) Rated Current 60-XXX-010-3-2 60-XXX-010-3-4 250VAC Leakage Current (Max.) CY Capacitance 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 60-XXX-010-5-4 0.35mA 250VAC 2200pF ± 20% 30°C 2.4mH 30°C 1.2mH 30°C 0.53mH 45°C .022uF ± 20% 0.26mH 45°C .01uF ± 20% 0.15mH 45°C .022uF ± 20% .022uF ± 20% .047uF ± 20% 2A 60-XXX-020-5-2 0.50mA 3300pF ± 20% 60-XXX-020-5-4 .022uF ± 20% .047uF ± 20% 60-XXX-030-3-2 60-XXX-030-3-4 6.0mH .022uF ± 20% .047uF ± 20% 60-XXX-020-3-2 60-XXX-020-3-4 Temperature Rise (Max.) .047uF ± 20% 1A 60-XXX-010-5-2 Inductance (L1) CX 0.35mA 250VAC .022uF ± 20% 2200pF ± 20% .047uF ± 20% 3A 60-XXX-030-5-2 0.50mA .022uF ± 20% 3300pF ± 20% 60-XXX-030-5-4 .047uF ± 20% 60-XXX-060-3-2 60-XXX-060-3-4 0.35mA 250VAC 2200pF ± 20% .047uF ± 20% 6A 60-XXX-060-5-2 0.50mA 3300pF ± 20% 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 0.35mA 2200pF ± 20% 60-XXX-060-5-4 60-XXX-100-3-2 250VAC 10A 250VAC 15A Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 45g Input: Compatible with IEC-320 40 .022uF ± 20% .047uF ± 20% 60-XXX-100-5-2 60-SPR-150-3-11 .022uF ± 20% * Substitute SPR or SPS for XXX 60-SPR - Fast-on terminals 60-SPS - Solder lug terminals SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Power Entry Modules Snap-in Mount 60-SPR & SPS Series .837 (21.3) .963 (24.5) 120 .853 (21.7) Panel cutout dimensions Current (%) 100 80 T: Panel Thickness T W .039 (1.0) 1.270 (32.3) .047 (1.2) 1.274 (32.4) .059 (1.5) 1.285 (32.5) 1.418 (35.9) .157 (4) 1.395 (35.5) * Standard terminal Fast-on tab #250 available as SPR series 2.096 (53.3) 20 30 40 50 60 70 Ambient Temperature (°C) 80 90 Solder lugs shown. Also available in fast-ons. Common Mode Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 60-SPX-010;-020;-030 50Ω 50Ω Level Meter 50Ω 60-SPX-010;-020;-030 80 80 70 70 60-SPX-010-5-X 60-SPX-010-X-4 Insertion Loss (dB) 60 50 40 60-SPX-020-5-X 30 60-SPX-030-5-X 20 10 60 50 60-SPX-020-X-4 40 60-SPX-030-X-4 30 20 10 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) Frequency (MHz) 60-SPX-060;-100 60-SPX-060;-100 80 80 70 70 Insertion Loss (dB) 60 60-SPX-60-5-X 50 40 30 60-SPX-100-5-X 20 10 0 0.1 Dimensions in inches (mm) Normal Mode 1 3 Filter 2 4 0 0.1 1.172 (29.8) * General tolerance ± .012 (0.3) 0 Insertion Loss (dB) Solder Lug 2 X 3 hole 40 20 Insertion Loss (dB) 1.805 (45.9) .252 (6.4) 60 W Panel cutout dimensions for 1.0t chassis 2.033 (51.7) Power Entry Modules R2 Temperature Characteristics 60-SPX-060-X-4 60 50 60-SPX-060-X-2 40 60-SPX-100-X-2 30 20 10 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 41 Fused Filtered Power Entry Modules For General Purpose Applications 64-65-BFF/64-65-BFS Series Features Fused Filtered Power Entry Modules ■ ■ ■ ■ ■ ■ ■ Tested and found to be IAW VDE 0565 Part 3. North American and Metric fuse holders available Fuse holder provides effective EMI suppression of common and differential mode Suitable for products that must conform to FCC and FTZ requirements Meets over voltage category II of IEC 664 and complies with IEC 950 Fast-on terminals or solder lug terminals Metal case provides effective EMI shielding Operating temperature: -25°C to +85°C (including temperature rise, see graph on page 43) ■ ■ ■ ■ L L L1 E R CY E CX CY Applications ■ Circuit Diagram N N Computers and peripheral equipment Electronic equipment Digital equipment Measuring and testing instruments Telecommunications equipment Specifications Model* 64-XXX-020-3-11 64-XXX-020-5-11 64-XXX-020-3-12 64-XXX-020-5-12 64-XXX-040-3-11 64-XXX-040-5-11 64-XXX-040-3-12 64-XXX-040-5-12 64-XXX-060-3-11 64-XXX-060-5-11 64-XXX-060-3-12 64-XXX-060-5-12 65-XXX-020-3-11 65-XXX-020-5-11 65-XXX-020-3-12 65-XXX-020-5-12 65-XXX-040-3-11 65-XXX-040-5-11 65-XXX-040-3-12 65-XXX-040-5-12 65-XXX-060-3-11 65-XXX-060-5-11 65-XXX-060-3-12 65-XXX-060-5-12 Rated Voltage (@ 50/60Hz) 250VAC 250VAC 250VAC 125VAC 125VAC 125VAC Rated Current 2A 4A 6A 2A 4A 6A Note: Test Voltage 1500VAC one minute, line to ground Insulation Resistance: 300 MΩ min. at 500VDC F(S) = Fast-on or (Solder lug terminals) 42 Leakage Current (Max.) 0.35mA 0.50mA 0.35mA 0.50mA 0.35mA 0.50mA 0.35mA 0.50mA 0.35mA 0.50mA 0.35mA 0.50mA 0.20mA 0.25mA 0.20mA 0.25mA 0.20mA 0.25mA 0.20mA 0.25mA 0.20mA 0.25mA 0.20mA 0.25mA Capacitance CY 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF CX ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% Voltage Drop: 1V max. at rated current Weight: 78g Inlet: Compatible with IEC-320 Inductance (L1) Temperature Rise (Max.) 6.5mH 40°C 4.2mH 45°C 1.6mH 45°C 6.5mH 40°C 4.2mH 45°C 1.6mH 45°C 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF * Substitute BFF or BFS for XXX BFF - Fast-on terminals BFS - Solder lug terminals SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Fused Filtered Power Entry Modules For General Purpose Applications 64-65-BFF/64-65-BFS Series Dimensions Temperature Characteristics 1.738 (44.2) 100 Current (%) 2.32 (59) .098 (2.5) 1.101 (28) Fuse cover 1.376 (35) 80 1.298 (33) 1.29 (32.8) 2 - .13 +.008 -.004 (2 - 3.3+0.2 -0.1) Hole 60 1.416±.008 (36±0.2) 0.252 (6.4) 1.14 (29) 1.616 (41.1) * Alternate Terminal for 64/65-BFS-Solder Lug Terminal 40 Fast-on tab#250 t= .031 (0.8) 20 0.158 (4.0) 0 20 30 40 50 60 70 Ambient Temperature (°C) 80 Fused Filtered Power Entry Modules 64/65-BFF Series 120 * General Tolerance: ±.020 (0.5) * Metal Case 90 2.249 (L:57.2) Dimensions in inches (mm) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 0.50 mA Leakage Versions 50Ω 50Ω Level Meter 50Ω 0.50 mA Leakage Versions 90 90 80 80 2 Amp 70 2 Amp Insertion Loss (dB) Insertion Loss (dB) 70 60 50 40 6 Amp 30 20 60 50 6 Amp 40 4 Amp 30 20 4 Amp 10 10 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 20 0 0.1 50 0.35 mA Leakage Versions 90 90 80 80 2 Amp Insertion Loss (dB) Insertion Loss (dB) 0.5 1 2 5 Frequency (MHz) 10 20 50 10 20 50 0.35 mA Leakage Versions 70 70 60 50 40 6 Amp 30 2 Amp 60 50 40 6 Amp 30 4 Amp 20 20 4 Amp 10 10 0 0.1 0.2 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 43 Fused Filtered Power Entry Modules For Medical or General Purpose Applications ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Medical equipment Electronic equipment Digital equipment Industrial equipment ■ ■ ■ Telecommunications equipment Measuring and testing instruments Personal computers and peripherals Circuit Diagrams 66/67-BFF(S)-XXX-0-X and 66/67-BFF(S)-XXX-4-X Filters 66/67-BFF(S)-XXX-1-X Filter L L L L L1 R L1 CX E E R CY CX E E CY N N N N Specifications Model* 66-XXX-020-1-11 66-XXX-020-1-12 66-XXX-020-0-11 66-XXX-020-4-11 66-XXX-020-0-12 66-XXX-020-4-12 66-XXX-040-1-11 66-XXX-040-1-12 66-XXX-040-0-11 66-XXX-040-4-11 66-XXX-040-0-12 66-XXX-040-4-12 66-XXX-060-1-11 66-XXX-060-1-12 66-XXX-060-0-11 66-XXX-060-4-11 66-XXX-060-0-12 66-XXX-060-4-12 67-XXX-020-1-11 67-XXX-020-1-12 67-XXX-020-0-11 67-XXX-020-4-11 67-XXX-020-0-12 67-XXX-020-4-12 67-XXX-040-1-11 67-XXX-040-1-12 67-XXX-040-0-11 67-XXX-040-4-11 67-XXX-040-0-12 67-XXX-040-4-12 67-XXX-060-1-11 67-XXX-060-1-12 67-XXX-060-0-11 67-XXX-060-4-11 67-XXX-060-0-12 67-XXX-060-4-12 Rated Voltage (@ 50/60Hz) Rated Current 0.01mA 250VAC 2A 0.075mA 0.1mA 0.075mA 0.1mA 0.01mA 250VAC 4A 0.075mA 0.1mA 0.075mA 0.1mA 0.01mA 250VAC 6A 0.075mA 0.1mA 0.075mA 0.1mA 0.005mA 125VAC 2A 0.035mA 0.05mA 0.035mA 0.05mA 0.005mA 125VAC 4A 0.035mA 0.05mA 0.035mA 0.05mA 0.005mA 125VAC 6A Note: Test Voltage 1500VAC one minute, line to ground Insulation Resistance: 300 MΩ min. at 500VDC F(S) = Fast-on or (Solder lug terminals) 44 Leakage Current (Max.) 0.035mA 0.05mA 0.035mA 0.05mA Capacitance CY none 330pF 470pF 330pF 470pF ± ± ± ± 20% 20% 20% 20% none 330pF 470pF 330pF 470pF ± ± ± ± 20% 20% 20% 20% none 330pF 470pF 330pF 470pF ± ± ± ± 20% 20% 20% 20% none 330pF 470pF 330pF 470pF ± ± ± ± 20% 20% 20% 20% none 330pF 470pF 330pF 470pF ± ± ± ± 20% 20% 20% 20% none 330pF 470pF 330pF 470pF ± ± ± ± 20% 20% 20% 20% Voltage Drop: 1V max. at rated current Weight: 78g Inlet: Compatible with IEC-320 CX 0.1uF 0.22uF 0.1uF Inductance (L1) Temperature Rise (Max.) 6.5mH 40°C 4.2mH 45°C 1.6mH 45°C 6.5mH 40°C 4.2mH 45°C 1.6mH 45°C 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF * Substitute BFF or BFS for XXX BFF - Fast-on terminals BFS - Solder lug terminals SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 LOAD ■ Applications LINE ■ Tested and found to be IAW VDE 0565 Part 3. Metric and North American fuse holders available Fuse holder provides effective EMI suppression of common and differential mode Suitable for products that must conform to FCC and FTZ requirements Meets over voltage category II of IEC 664 and complies with IEC 950 Fast-on terminations or solder lug terminations Metal case provides effective EMI shielding Provides susceptibility protection without the leakage current associated with line-to-ground capacitance Reduces the line to ground capacitance in order to meet patient care requirements Operating temperature: -25°C to +85°C (including temperature rise, see graph on page 45) LOAD Fused Filtered Power Entry Modules ■ LINE 66-67-BFF/66-67-BFS Series Features Fused Filtered Power Entry Modules For Medical or General Purpose Applications 66-67-BFF/66-67-BFS Series Dimensions Temperature Characteristics 1.738 (44.2) 2.32 (59) .098 (2.5) 1.101 (28) 100 Current (%) Fuse cover 1.376 (35) 80 1.298 (33) 60 1.416±.008 (36±0.2) 40 1.29 (32.8) 2 - .13 +.008 -.004 (2 - 3.3+0.2 -0.1) Hole 0.252 (6.4) 1.14 (29) 1.616 (41.1) * Alternate Terminal for 66/67-BFS-Solder Lug Terminal Fast-on tab#250 t= .031 (0.8) 20 0.158 (4.0) 0 20 30 40 50 60 70 Ambient Temperature (°C) 80 2.249 (L:57.2) Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 90 90 80 80 70 70 Insertion Loss (dB) Insertion Loss (dB) 50Ω 60 2 Amp 40 30 60 2 Amp 50 30 0 0.1 0.2 0.5 10 1 2 5 Frequency (MHz) 10 20 0 0.1 50 80 80 70 70 Insertion Loss (dB) 90 60 2 Amp 50 0.2 0.5 1 2 5 Frequency (MHz) 40 30 10 0.2 0.5 20 50 60 50 2 Amp 40 30 4 Amp 20 20 6 Amp 6 Amp 4 Amp 10 0.075 and 0.1 mA Leakage Current 0.075 and 0.1 mA Leakage Current 90 0 0.1 6 Amp 6 Amp 4 Amp 4 Amp 40 20 20 10 50Ω Level Meter 50Ω 0.01 mA Leakage Current 0.01 mA Leakage Current Insertion Loss (dB) Dimensions in inches (mm) Normal Mode 1 3 Filter 2 4 50 * General Tolerance: ±.020 (0.5) * Metal Case 90 Common Mode Fused Filtered Power Entry Modules 66-67-BFF/66-67-BFS Series 120 10 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 45 Switched and Fused Filtered Power Entry Modules Switched and Fused Filtered Power Entry Modules For General Purpose Applications 64-65-BSF/64-65-SSF Series Features ■ ■ ■ ■ ■ ■ ■ ■ Tested and found to be IAW VDE 0565 Part 3. North American and Metric fuse holders available Fuse holder and double pole power ON/OFF switch provided in a convenient/compact package Suitable for products that must conform to FCC and FTZ requirements Meets over voltage category II of IEC 664 and complies with IEC 950 Metal case provides effective EMI shielding Easy access fuse drawer with space for spare fuse Flange-mounted or snap-in styles available for quick mounting Operating temperature: -25°C to +85°C (including temperature rise, see graph on page 47) Applications ■ ■ Computers and peripheral equipment Electronic equipment ■ ■ ■ Digital equipment Measuring and testing instruments Telecommunications equipment Circuit Diagram L L CY CX E CX E R CY N N Specifications Model* Rated Voltage (@ 50/60Hz) Rated Current 64-XXX-020-3-12 64-XXX-020-3-04 64-XXX-020-3-14 64-XXX-020-3-06 250VAC 2A 64-XXX-020-5-12 64-XXX-020-5-04 64-XXX-020-5-14 64-XXX-020-5-06 64-XXX-040-3-12 64-XXX-040-3-04 64-XXX-040-3-14 64-XXX-040-3-06 250VAC 4A 64-XXX-040-5-12 64-XXX-040-5-04 64-XXX-040-5-14 64-XXX-040-5-06 64-XXX-060-3-12 64-XXX-060-3-04 64-XXX-060-3-14 64-XXX-060-3-06 250VAC 6A 64-XXX-060-5-12 64-XXX-060-5-04 64-XXX-060-5-14 64-XXX-060-5-06 65-XXX-020-3-12 65-XXX-020-3-04 65-XXX-020-3-14 65-XXX-020-3-06 125VAC 2A 65-XXX-020-5-12 65-XXX-020-5-04 65-XXX-020-5-14 65-XXX-020-5-06 65-XXX-040-3-12 65-XXX-040-3-04 65-XXX-040-3-14 65-XXX-040-3-06 125VAC 4A 65-XXX-040-5-12 65-XXX-040-5-04 65-XXX-040-5-14 65-XXX-040-5-06 65-XXX-060-3-12 65-XXX-060-3-04 65-XXX-060-3-14 65-XXX-060-3-06 125VAC 6A 65-XXX-060-5-12 65-XXX-060-5-04 65-XXX-060-5-14 65-XXX-060-5-06 Note: Test Voltage 1500VAC one minute, line to ground Insulation Resistance: 300 MΩ min. at 500VDC B(S) = Bolt-in terminals or (Snap-in terminals) 46 Leakage Current (Max.) CY 0.35mA 2200pF Capacitance CX1 0.22uF 0.47uF 0.22uF 0.50mA 3300pF 0.47uF 0.22uF 0.35mA 2200pF 0.47uF 0.22uF 0.50mA 3300pF 0.47uF 0.22uF 0.35mA 0.47uF 2200pF 0.22uF 0.50mA 0.47uF 0.22uF 0.35mA 2200pF 0.47uF 0.22uF 0.50mA 3300pF 0.47uF 0.22uF 0.35mA 2200pF 0.47uF 0.22uF 0.50mA 3300pF 0.47uF 0.22uF 0.35mA 0.47uF 2200pF 0.22uF 0.50mA 0.47uF Voltage Drop: 1V max. at rated current Weight: 130g Inlet: Compatible with IEC-320 CX2 Inductance (L1) NONE 0.22uF NONE 10.5mH 0.47uF NONE 0.22uF NONE 0.47uF NONE 0.22uF NONE 0.47uF 4.2mH NONE 0.22uF NONE 0.47uF NONE 0.22uF NONE 0.47uF 1.6mH NONE 0.22uF NONE 0.47uF NONE 0.22uF NONE 0.47uF 10.5mH NONE 0.22uF NONE 0.47uF NONE 0.22uF NONE 0.47uF 4.2mH NONE 0.22uF NONE 0.47uF NONE 0.22uF NONE 0.47uF 1.6mH NONE 0.22uF NONE 0.47uF * Substitute BSF or SSF for XXX BSF - Bolt-in switched and fused SSF - Snap-in switched and fused Temperature Rise (Max.) 45°C 45°C 45°C 45°C 45°C 45°C SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Temperature Temperature Characteristics Characteristics 120 100 Current (%) Switched and Fused Filtered Power Entry Modules 80 60 40 20 0 Dimensions 30 40 50 60 70 Ambient Temperature (°C) 80 90 64/65-SSF Series 64/65-BSF Series 1.947 (49.5) 1.101 (28) 20 1.313 (33.4) 1.101 (28) .248 (6.3) .248 (6.3) 1.133 (28.8) 1.514 (38.8) 1.526 (38.8) Fast-on tab #250 t= .031 (0.8) 2.556 (65) 2.556 (65) 2.340 (59.5) 2.348 (59.7) 2.348 (59.7) 2.340 (59.5) Ø.142 (3.6) R .079 (2.0) 2 - .142 (3.6) Hole R .059 (1.5) A t= .031 (0.8) Panel cutout dimension mount from back side 1.573 1.16±.334 0 (40.±0.2) (29.5± 0.5) 0 Thickness of Panel .031 (0.8t) .039 (1.0t) .047 (1.2t) .059 (1.5t) .071 (1.8t) .079 (2.0t) 1.133 (28.8) Fast-on Tab #250 2.273 (57.8) 1.573 (40±0.2) 2.273 (57.8) Dimensions in inches (mm) Panel cutout dimension mount from back side 1.16 +.02 -0 (29.5 +0.5 -0 ) A 2.430 (61.8±0.1) 2.446 (62.2±0.1) 2.462 (62.6±0.1) 2.470 (62.8±0.1) 2.473 (62.9±0.1) 2.477 (63.0±0.1) Switched and Fused Filtered Power Entry Modules For General Purpose Applications * General Tolerance ± .039 (1.0) * Metal Case 2.399 (61) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 50Ω 1 3 Filter 2 4 50Ω Level Meter Oscillator 50Ω 0.35 mA Leakage Versions 100 80 90 70 80 2 Amp Insertion Loss (dB) Insertion Loss (dB) 50Ω Level Meter 50Ω 64/65-B(S)SF-*-*-02(04,06) 90 60 50 40 4 Amp 30 6 Amp 20 70 60 50 2 Amp 40 4 Amp 30 10 6 Amp 20 0 0.1 0.2 1 0.5 2 5 Frequency (MHz) 10 20 0 0.1 50 0.50 mA Leakage Versions 0.5 1 2 5 Frequency (MHz) 10 20 50 20 50 100 80 90 70 80 Insertion Loss (dB) 2 Amp 60 50 40 4 Amp 30 6 Amp 20 70 60 4 Amp 6 Amp 50 2 Amp 40 30 10 0 0.1 0.2 64/65-B(S)SF-*-*-11(12,14) 90 Insertion Loss (dB) 50Ω 20 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 47 Switched and Fused Filtered Power Entry Modules 66-67-BSF/66-67-SSF Series Features Tested and found to be IAW VDE 0565 Part 3 Metric and North American fuse holders available Fuse holder and a double pole power ON/OFF switch provides a convenient/compact package ■ Suitable for products that must conform to FCC and FTZ requirements ■ Meets over voltage category II of IEC 664 and complies with IEC 950 ■ Provides susceptibility protection without the leakage current associated with line-to-ground capacitors ■ Designed to meet requirements for non-patient and patient care equipment ■ Metal case provides effective EMI shielding ■ Easy access fuse drawer - space for spare fuse ■ Flange-mounted or snap-in styles available for quick mounting ■ Operating temperature: -25°C to +85°C (including temperature rise, see graph on page 49) ■ ■ Applications ■ ■ ■ ■ Medical equipment Industrial equipment Telecommunications equipment Measuring and testing instruments ■ ■ Digital equipment (including switching power supplies) General purpose filter for susceptibility or high frequency “clean up” applications Circuit Diagram L L L1 R CX1 CX2 CY1 E E LOAD Note: CY1 and CY2 capacitors omitted on 66/67 B(S)F-XXX-1-X Filters LINE Switched and Fused Filtered Power Entry Modules For Medical or General Purpose Applications CY2 N N Specifications Model* 66-XXX-020-0-12 66-XXX-020-0-04 66-XXX-020-0-14 66-XXX-020-0-06 66-XXX-020-1-12 66-XXX-020-1-04 66-XXX-020-1-14 66-XXX-020-1-06 66-XXX-020-4-12 66-XXX-020-4-04 66-XXX-020-4-14 66-XXX-020-4-06 66-XXX-040-0-12 66-XXX-040-0-04 66-XXX-040-0-14 66-XXX-040-0-06 66-XXX-040-1-12 66-XXX-040-1-04 66-XXX-040-1-14 66-XXX-040-1-06 66-XXX-040-4-12 66-XXX-040-4-04 66-XXX-040-4-14 66-XXX-040-4-06 66-XXX-060-0-12 66-XXX-060-0-04 66-XXX-060-0-14 66-XXX-060-0-06 66-XXX-060-1-12 66-XXX-060-1-04 66-XXX-060-1-14 66-XXX-060-1-06 66-XXX-060-4-12 66-XXX-060-4-04 66-XXX-060-4-14 66-XXX-060-4-06 Rated Rated Leakage Voltage Current Current Capacitance 50/60Hz (Max.) CY CX1 CX2 0.22uF .075mA 330pF 0.47uF 0.22uF 2A .01mA NONE 0.47uF 0.22uF 0.1mA 470pF 0.47uF 0.22uF .075mA 330pF 0.47uF 250 VAC 0.22uF 4A .01mA NONE 0.47uF 0.22uF .01mA 470pF 0.47uF 0.22uF .075mA 330pF 0.47uF 0.22uF 6A .01mA NONE 0.47uF 0.22uF 0.1mA 470pF 0.47uF Rise (Max.) NONE 0.22uF NONE 0.22uF NONE 0.22uF 10.5mH 40°C NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF 4.2mH NONE 0.22uF NONE 0.22uF NONE 0.22uF 45°C NONE 0.22uF NONE 0.22uF NONE 0.22uF 1.6mH NONE 0.22uF NONE 0.22uF NONE 0.22uF Note: Test Voltage: 1500VAC one minute, line to ground Insulation Resistance: 300 MΩ min. at 500VDC Voltage Drop: 1V max. at rated current 48 Temp. Induct. (L1) Model* 67-XXX-020-0-12 67-XXX-020-0-04 67-XXX-020-0-14 67-XXX-020-0-06 67-XXX-020-1-12 67-XXX-020-1-04 67-XXX-020-1-14 67-XXX-020-1-06 67-XXX-020-4-12 67-XXX-020-4-04 67-XXX-020-4-14 67-XXX-020-4-06 67-XXX-040-0-12 67-XXX-040-0-04 67-XXX-040-0-14 67-XXX-040-0-06 67-XXX-040-1-12 67-XXX-040-1-04 67-XXX-040-1-14 67-XXX-040-1-06 67-XXX-040-4-12 67-XXX-040-4-04 67-XXX-040-4-14 67-XXX-040-4-06 67-XXX-060-0-12 67-XXX-060-0-04 67-XXX-060-0-14 67-XXX-060-0-06 67-XXX-060-1-12 67-XXX-060-1-04 67-XXX-060-1-14 67-XXX-060-1-06 67-XXX-060-4-12 67-XXX-060-4-04 67-XXX-060-4-14 67-XXX-060-4-06 Rated Rated Leakage Voltage Current Current Capacitance 50/60Hz (Max.) CY CX1 CX2 0.22uF 0.04mA 330pF 0.47uF 0.22uF 2A .005mA NONE 0.47uF 0.22uF 0.05mA 470pF 0.47uF 0.22uF 0.04mA 330pF 0.47uF 125 VAC 0.22uF 4A .005mA NONE 0.47uF 0.22uF 0.05mA 470pF 0.47uF 0.22uF 0.04mA 330pF 0.47uF 0.22uF 6A Weight: 130g Inlet: Compatible with IEC-320 B(S) = Bolt-in terminals or (Snap-in terminals) .005mA NONE 0.47uF 0.22uF 0.05mA 470pF 0.47uF Temp. Induct. (L1) Rise (Max.) NONE 0.22uF NONE 0.22uF NONE 0.22uF 10.5mH 40°C NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF 4.2mH NONE 0.22uF NONE 0.22uF NONE 0.22uF 45°C NONE 0.22uF NONE 0.22uF NONE 0.22uF 1.6mH NONE 0.22uF NONE 0.22uF NONE 0.22uF * Substitute BSF or SSF for XXX BSF - Bolt-In Switched and Fused SSF - Snap-In Switched and Fused SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Temperature Characteristics 120 100 Current (%) Switched and Fused Filtered Power Entry Modules For Medical or General Purpose Applications 80 60 40 20 20 30 40 50 60 70 Ambient Temperature (°C) 80 90 Dimensions 66/67-BSF Series 1.947 (49.5) 1.101 (28) 66/67-SSF Series .248 (6.3) 1.313 (33.4) 1.101 (28) 1.526 (38.8) .248 (6.3) 1.133 (28.8) 1.514 (38.8) Fast-on tab #250 2.556 (65) t= .031 (0.8) 2.556 (65) 2.348 (59.7) 2.340 (59.5) Ø.142 (3.6) 2 - .142 (3.6) Hole R .079 (2.0) 1.133 (28.8) Fast-on Tab #250 2.273 (57.8) 1.573 (40±0.2) 2.340 (59.5) 2.348 (59.7) R .059 (1.5) A Dimensions in inches (mm) 2.399 (61) Common Mode 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 80 80 70 70 Insertion Loss (dB) Insertion Loss (dB) 90 60 2 Amp 40 30 20 2 Amp 50 40 30 4 Amp 6 Amp 10 10 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 20 0 0.1 50 90 80 80 70 70 Insertion Loss (dB) 90 60 2 Amp 50 40 30 20 1 2 5 Frequency (MHz) 10 20 50 2 Amp 60 50 40 4 Amp 30 6 Amp 10 10 0 0.1 0.5 20 6 Amp 4 Amp 0.2 0.075 and 0.1 mA Leakage Current 0.075 and 0.1 mA Leakage Current Insertion Loss (dB) 50Ω Level Meter 50Ω 60 20 6 Amp 4 Amp 50Ω 0.01 mA Leakage Current 0.01 mA Leakage Current 90 50 * General Tolerance ± .039 (1.0) * Metal Case Panel cutout dimension mount from back side 1.16 +.02 -0 (29.5 +0.5 -0 ) A 2.430 (61.8±0.1) 2.446 (62.2±0.1) 2.462 (62.6±0.1) 2.470 (62.8±0.1) 2.473 (62.9±0.1) 2.477 (63.0±0.1) Normal Mode 1 3 Filter 2 4 Oscillator 50Ω Thickness of Panel .031 (0.8t) .039 (1.0t) .047 (1.2t) .059 (1.5t) .071 (1.8t) .079 (2.0t) t= .031 (0.8) Panel cutout dimension mount from back side 1.573 1.16 +.02 -0 (40.±0.2) (29.5 +0.5) -0 2.273 (57.8) Switched and Fused Filtered Power Entry Modules 0 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 49 Switched and Fused Filtered Power Entry Modules Switched and Fused Filtered Power Entry Modules Dual Fuse for European Applications 68-BSF Series Features Dual fuse for European applications Fuse holder and double pole power ON/OFF switch provides a convenient/compact package ■ Suitable for products that must conform to FCC and FTZ requirements ■ Meets over voltage category II of IEC 664 and complies with IEC 950 ■ Metal case provides effective EMI shielding ■ IEC connector meets the safety standards of most certifying agencies ■ Easy access fuse drawer ■ Flange-mounted ■ UL, CSA, and SEMKO approved ■ Designed to be in accordance with VDE 0565, part 3 ■ Operating temperature: -25°C to +85°C (including temperature rise, see graph on page 51) ■ ■ Circuit Diagram FUSE L L L1 E CY1 CX2 CX1 E R1 L2 CY2 N N SW Applications Computers and peripheral equipment Electronic equipment ■ Digital equipment ■ Measuring and testing instruments ■ Telecommunications equipment ■ ■ Specifications Model Rated Voltage (@ 50/60Hz) 68-BSF-020-3-01 Rated Current Leakage Current (Max.) CY1 Capacitance CY2 CX1 2A 68-BSF-020-3-04 68-BSF-040-3-01 250VAC 4A 68-BSF-040-3-04 68-BSF-060-3-01 6A 68-BSF-060-3-04 0.35mA 2200pF 2200pF CX2 0.1uF 0.1uF 0.22uF 0.22uF 0.1uF 0.1uF 0.22uF 0.22uF 0.1uF 0.1uF 0.22uF 0.22uF Inductance (L1) Temperature Rise (Max.) 10.5mH 4.2mH 45°C 1.6mH Note: Test Voltage 1500VAC one minute, line to ground Insulation Resistance: 300 MΩ min. at 500VDC Voltage Drop: 1V max. at rated current Weight: 130g Inlet: Compatible with IEC-320 B(S) = Bolt-in terminals or (Snap-in terminals) 50 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Switched and Fused Filtered Power Entry Modules Dual Fuse for European Applications Temperature Characteristics 1.947 (49.5) 1.101 (28) .248 (6.3) 1.526 (38.8) 120 2.556 (65) Current (%) 100 80 2.348 (59.7) 60 2 - .142 (3.6) Hole 20 30 40 50 60 70 Ambient Temperature (°C) 80 90 Dimensions in inches (mm) Normal Mode 1 3 Filter 2 4 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 90 50Ω 50Ω Level Meter 50Ω 100 90 70 80 Insertion Loss (dB) 80 60 50 40 4 Amp 30 2 Amp 6 Amp 20 70 4 Amp 60 50 2 Amp 40 30 10 0 0.1 t= .031 (0.8) 2.399 (61) Common Mode Oscillator 50Ω R .059 (1.5) Panel cutout dimension mount from back side 1.573 1.16 +.02 -0 (40.±0.2) (29.5 +0.5) -0 0 1.133 (28.8) Fast-on Tab #250 2.273 (57.8) 1.573 (40±0.2) 40 20 Insertion Loss (dB) 2.340 (59.5) Ø.142 (3.6) Switched and Fused Filtered Power Entry Modules 68-BSF Series 6 Amp 20 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 51 PCB Power Filters Miniature Printed Circuit Board 61-MPC Series Tested and found to be IAW VDE 0565 Part 3 Features ■ ■ ■ ■ ■ PCB Power Filters ■ Miniature general purpose PCB mounted filter Requires minimal PCB real estate space Low cost Designed for two wire cord systems For three wire cord systems, Y capacitors can be attached externally Operating temperature: -25°C to +85°C (including temperature rise, see graph on page 53) Circuit Diagram 3 1 Applications ■ ■ ■ ■ ■ L1 Personal computers and peripherals Digital equipment Measuring instruments and medical equipment TV & VCR monitors and display units Home appliances CX1 CX1 2 4 Specifications Model Rated Voltage (@ 50/60Hz) 61-MPC-010-1-11 61-MPC-016-1-11 61-MPC-025-1-11 61-MPC-036-1-11 Rated Current Leakage Current (Max.) Capacitance CX1 CX2 1A 250VAC 1.6A 2.5A 3.6A Inductance (L1) Temperature Rise (Max.) 11mH 0.1mA 0.01uF 0.01uF 6.0mH 2.4mH 40°C 1.2mH Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 17.5g 52 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PCB Power Filters Miniature Printed Circuit Board 61-MPC Series 4 3 4 — .031 (.8) .551 (14) 2 .767 (19.5) .059 (1.5) .590 (15) 1.239 (31.5) .354 (9) Dimensions in inches (mm) Temperature Characteristics Common Mode 120 1 3 Filter 2 4 Oscillator 50Ω 100 50Ω Level Meter 50Ω 1 3 Filter 2 4 (Test circuit 2) Oscillator 50Ω Current (%) Common mode with Y cap. (Test circuit 1) PCB Power Filters 1 .767 (19.5) 50Ω Level Meter 50Ω 80 60 40 20 0 0 30 40 50 60 70 80 Ambient Temperature (°C) 90 100 61-MPC 80 Y Cap 2 X 3300pF 70 Insertion Loss (dB) 61-MPC-010-1-11 Normal Mode 60 50 1 3 Filter 2 4 40 (Test circuit 3) 61-MPC-016-1-11 30 61-MPC-025-1-11 Oscillator 50Ω 20 50Ω 50Ω Level Meter 50Ω 61-MPC-036-1-11 10 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 61-MPC 61-MPC 80 80 70 70 60 Insertion Loss (dB) Insertion Loss (dB) 61-MPC-010-1-11 50 40 30 61-MPC-016-1-11 20 61-MPC-036-1-11 0.5 1 61-MPC-010-1-11 40 61-MPC-016-1-11 30 61-MPC-025-1-11 20 10 10 0.2 50 61-MPC-036-1-11 61-MPC-025-1-11 0 0.1 60 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 53 Power Entry Modules Bolt-in Right Angle Terminals for PCB Applications 60-BPP Series Tested and found to be IAW VDE 0565 Part 3 Features ■ ■ ■ ■ PCB Power Filters ■ ■ ■ Ideally suited for products that must conform to FCC part 15 regulations Metal case offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards Solder lug, Fast-on tab styles available (see page 26) PCB mounting style minimizes space and provides economical installation Operating temperature: -25°C to +85°C (including temperature rise, see graph on page 55) UL approved low leakage version also available ■ ■ ■ 3 1 CY L1 CX E E Applications ■ Circuit Diagram CY Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units 2 4 Specifications Model Rated Voltage (@ 50/60Hz) Rated Current 60-BPP-010-3-2 60-BPP-010-3-4 Leakage Current (Max.) CY Capacitance 0.35mA 2200pF 0.50mA 3300pF 60-BPP-020-3-2 0.35mA 60-BPP-020-3-4 2200pF 0.50mA 3300pF 0.022uF 2.4mH 30°C 0.022uF 0.047uF 250VAC 60-BPP-030-3-2 0.35mA 2200pF 0.022uF 0.047uF 3A 60-BPP-030-5-2 0.50mA 3300pF 0.047uF 60-BPP-060-3-2 0.022uF 0.35mA 2200pF 0.047uF 6A 60-BPP-060-5-2 60-BPP-060-5-4 0.50mA 3300pF 1.2mH 0.022uF 60-BPP-030-5-4 60-BPP-060-3-4 6.0mH 0.022uF 0.047uF 2A 60-BPP-020-5-2 60-BPP-030-3-4 Temperature Rise (Max.) 0.047uF 60-BPP-010-5-4 60-BPP-020-5-4 Inductance (L1) 0.022uF 0.047uF 1A 60-BPP-010-5-2 CX 0.53mH 45°C 0.022uF 0.047uF Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 50g Input: Compatible with IEC-320 54 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Power Entry Modules Bolt-in Right Angle Terminals for PCB Applications 60-BPP Series .098 (2.5) 120 Current (%) 100 1.463 (37.2) 1.967 (50) 1.317 (33.5) 1.573 (40) .885 (22.5) 2- .142 (3.6) 80 .047 (1.2) .232 (5.9) 60 .024 (.6) 5 . R4 .865 (22) 40 2- .142 (3.6) 1.573 (40) * General tolerance ± .012 (.3) .142 .059 (3.6) (1.5) .031 (.8) 1.070 (27.2) 1.180 (30) .779 1.180 (19.8) (30) .708 (18) Panel cutout dimensions mounts from backside 20 0 .991 (25.2) .590 (15) 20 30 40 50 60 70 Ambient Temperature (°C) 80 Dimensions in inches (mm) 90 Common Mode PCB Power Filters Temperature Characteristics 60-BPP PCB Mounting Type Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 50Ω 50Ω Level Meter 50Ω 60-BPP-010;-020 60-BPP-010;-020 80 80 70 70 60 Insertion Loss (dB) Insertion Loss (dB) 60-BPP-010-3-X 50 60-BPP-020-3-X 40 30 20 60-BPP-010-X-4 50 40 30 60-BPP-020-X-4 20 10 10 0 0.1 60 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 Frequency (MHz) 5 10 20 50 20 50 60-BPP-030;-060 80 70 70 60 Insertion Loss (dB) Insertion Loss (dB) 60-BPP-030;-060 80 60-BPP-030-3-X 50 40 60-BPP-060-3-X 30 20 10 0 0.1 2 Frequency (MHz) 60 50 40 60-BPP-030-X-4 30 60-BPP-060-X-4 20 10 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 Frequency (MHz) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 55 Power Entry Modules High Frequency Attenuation Bolt-in for PCB Applications 60-BHP Series Tested and found to be IAW VDE 0565 Part 3 Features ■ ■ ■ ■ ■ PCB Power Filters ■ ■ ■ Ideally suited for products that must conform to FCC part 15 regulations Metal cased filter offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Solder lug, Fast-on tab styles available (see page 28) PCB mounting minimizes space and provides economical installation Excellent filtering characteristics for high frequencies Earth coil standard Operating temperature: -25°C to +85°C (including temperature rise, see graph on page 57) Circuit Diagram ■ ■ ■ CY L1 Applications ■ 3 1 CX E E Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units CY 2 4 L2 Specifications Model Rated Voltage (@ 50/60Hz) Rated Current 60-BHP-010-3-11 Leakage Current (Max.) 0.35mA 60-BHP-010-3-4 Capacitance CY 2200pF±20% 0.50mA 3300pF±20% 60-BHP-010-5-4 0.35mA 60-BHP-020-3-4 2200pF±20% 0.50mA 3300pF±20% 0.35mA 2200pF±20% 2.4mH 0.50mA 3300pF±20% 60-BHP-030-5-4 30°C 0.1uF±20% 18.3 uH 0.1uF±20% .047uF±20% 3A 60-BHP-030-5-11 1.2mH 0.1uF±20% .047uF±20% 60-BHP-060-3-11 60-BHP-060-5-11 0.1uF±20% .047uF±20% 250VAC 60-BHP-030-3-11 60-BHP-060-3-4 6mH 0.1uF±20% .047uF±20% 2A 60-BHP-020-5-11 60-BHP-030-3-4 Temperature Rise (Max.) .047uF±20% 60-BHP-020-3-11 60-BHP-020-5-4 Inductance (L1) (L2) 0.1uF±20% .047uF±20% 1A 60-BHP-010-5-11 CX 0.35mA 2200pF±20% 0.1uF±20% .047uF±20% 6A 0.50mA 60-BHP-060-5-4 3300pF±20% 0.53mH 45°C 0.1uF±20% .047uF±20% Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 50g Input: Compatible with IEC-320 56 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Power Entry Modules High Frequency Attenuation Bolt-in for PCB Applications 60-BHP Series 120 .991 (25.2) .590 (15) 2- .142 (3.6) .5 2- .142 (3.6) 1.573 (40) 40 .059 (1.5) .031 (.8) 1.070 (27.2) .024 (.6) R4 .865 (22) .142 (3.6) .047 (1.2) .232 (5.9) 1.180 (30) 80 60 1.534 (39) 1.389 (35.3) .885 (22.5) 100 Current (%) .098 (2.5) 1.967 (50) 1.573 (40) .779 1.180 (19.8) (30) .708 (18) Panel cutout dimensions mounts from backside 20 Dimensions in inches (mm) 0 20 30 40 50 60 70 Ambient Temperature (°C) 80 90 Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 90 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 60-BHP-XXX-X-11 90 80 Insertion Loss (dB) Insertion Loss (dB) 60-BHP-020-X-11 50 40 60-BHP-030-X-11 30 60-BHP-060-X-11 60-BHP-010-3-11 50 60-BHP-020-3-11 40 60-BHP-030-3-11 30 60-BHP-060-3-11 10 10 1 0.5 60-BHP-XXX-3-11 60 20 0.2 2 5 10 20 0 0.1 50 0.2 0.5 1 Frequency (MHz) 90 5 10 20 50 60-BHP-XXX-3-4 90 80 80 60-BHP-010-X-4 70 Insertion Loss (dB) Insertion Loss (dB) 2 Frequency (MHz) 60-BHP-XXX-X-4 60-BHP-020-X-4 60 50 40 60-BHP-030-X-4 30 60-BHP-060-X-4 70 60-BHP-010-3-4 60 50 60-BHP-020-3-4 40 60-BHP-030-3-4 30 60-BHP-060-3-4 20 20 10 10 0 0.1 50Ω Level Meter 50Ω 70 20 0 0.1 50Ω 80 60-BHP-010-X-11 70 60 PCB Power Filters 60-BHP PCB Mounting Type Temperature Characteristics 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 57 PCB Power Filters Miniature Printed Circuit Board 11-MPC Series Features ■ ■ ■ ■ ■ Miniature general purpose PCB mounted filter Requires minimal PCB real estate space Low cost Operating temperature: -25°C to +70°C Two forms of cases are available: metal case and plastic case Circuit Diagram Circuit 1 PCB Power Filters Applications ■ ■ ■ ■ ■ Personal computers and peripherals Digital equipment Measuring instruments and medical equipment TV & VCR monitors and display units Home appliances Circuit 2 Circuit 3 Specifications Model Rated Voltage (@ 50/60Hz) Rated Current 11-MPC-001-2-B Leakage Current (Max.) Circuit Diagram Figure 5uA 1 B 1A 11-MPC-001-5-A A 2 11-MPC-001-5-B 11-MPC-002-5-B 11-MPC-002-5-D 11-MPC-003-5-E 11-MPC-006-5-B 11-MPC-006-5-C 11-MPC-016-5-B 120/250VAC 2A 0.50mA 3A 6A 16A Temperature Rise (Max.) 3 2 0.2mA 4 B D 30°C E B C B Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 17.5g 58 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PCB Power Filters Miniature Printed Circuit Board 11-MPC Series Figure A Figure C Figure B .03 (1) (5X) 0.6 0.9 (16) (25) .30 (7.5) 2.0 0.9 (25)±.007 (51) 0.6 (16) 0.9 (25) 0.6 (15) 0.4 (10) 1.9 (30) .30 (7.5) 2.5 (64) Figure D .79 (20) 1.1 (29) 0.9 (25) 1.7 (44) 0.6 (15) ±.03 1.4 (36) .60 (15) ±.07 0.3 (8) 0.3 (8) .45 (11.5) 1.4 (35) 1.1 (28) .45 (11.5) 0.6 (16) 1.4 (36) 1.8 (45) 1.4 (35.5) 1.9 (49) 0.6 (15) ±.07 1.1 (27) Common Mode .15 (4) Dimensions in inches (mm) Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 50Ω PCB Power Filters Figure E 0.03 (1) (5X) 50Ω Level Meter 50Ω 11-MPC-001;-002 11-MPC-001;-002 80 80 11-MPC-002-5-D 70 70 11-MPC-001-5-A 60 11-MPC-001-2-B 50 40 11-MPC-002-5-D 30 20 Insertion Loss (dB) Insertion Loss (dB) 11-MPC-001-5-B 60 11-MPC-001-5-B 50 11-MPC-001-2-B 40 30 20 11-MPC-001-5-A 11-MPC-002-5-B 10 10 11-MPC-002-5-B 0 0.1 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) Frequency (MHz) 11-MPC-003;-006;-016 11-MPC-003;-006;-016 80 80 70 70 60 Insertion Loss (dB) Insertion Loss (dB) 11-MPC-006-5-C 11-MPC-003-5-E 50 11-MPC-006-5-B 40 30 11-MPC-016-5-B 20 60 11-MPC-016-5-B 50 11-MPC-003-5-E 40 30 11-MPC-006-5-C 20 11-MPC-006-5-B 10 0 0.1 10 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 59 Power Line Filters Appliance Filters 62-AL/62-AC Series Features ■ ■ ■ ■ ■ ■ ■ Tested and found to be IAW VDE 0565 Part 3 Low-cost plastic case Compact design requires minimal real estate space Suitable for products that must conform to FCC regulations Wide variety of circuit and filtering options Good filtering characteristics for both normal mode and common mode Epoxy molded for reliability Operating temperature: -25°C to +85°C (including temperature rise, see graph on page 61) Fast-on tab #110 .629 (16.0) 1.220 (31.0) 1.573 (40.0) .177 x .138 (4.5 x 3.5) .994 (24.0) .371 (9.4) .371 (9.4) 1.527 (38.8) .657 (16.7) .374 (9.5) .263 (6.7) Applications ■ Power Line Filters ■ ■ ■ ■ ■ Dimensions in inches (mm) Circuit Diagrams Personal computers and peripherals Digital equipment Industrial equipment Vending machines Home appliances Office equipment L 62-A*L Series 62-AFL-010-3-11 62-AFC-010-3-11 62-AFL-010-5-11 62-AFC-010-5-11 62-AFL-016-3-11 62-AFC-016-3-11 62-AFL-016-5-11 62-AFC-016-5-11 62-AFL-030-3-11 62-AFC-030-3-11 62-AFL-030-5-11 62-AFC-030-5-11 62-AFL-045-3-11 62-AFC-045-3-11 62-AFL-045-5-11 62-AFC-045-5-11 62-AFL-060-3-11 62-AFC-060-3-11 62-AFL-060-5-11 62-AFC-060-5-11 Rated Current Leakage Current (Max.) CY Capacitance 0.35mA 2200pF 0.50mA 3300pF 0.35mA 2200pF 0.50mA 3300pF 0.35mA 2200pF 0.50mA 3300pF 0.35mA 2200pF 0.50mA 3300pF 0.35mA 2200pF 0.50mA 3300pF R CX CY1 CY2 Inductance (L1) Temperature Rise (Max.) 11.0mH 1.6A 6.0mH 0.1uF 3.0A 4.5A 2.4mH 40°C 1.0mH 6.0A 0.53mH Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3 Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. 60 CX 1.0A 250VAC CY2 * R= w/ Bleeder Resistor F = w/o Bleeder Resistor Specifications Rated Voltage (@ 50/60Hz) CY1 L 62-A*C Series Model* CX R * Available with bleeder resistor Replace F with R for part number SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Temperature Characteristics 120 100 Current (%) Power Line Filters Appliance Filters 80 60 40 20 0 Normal 20 Mode 30 40 50 60 70 Ambient Temperature (°C) 62-AL/62-AC Series Common Mode 80 90 Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 50Ω 50Ω Level Meter 50Ω 62-AFL-XXX-3-11 62-AFL-xxx-3-11 80 80 62-AFL-030-3-11 70 62-AFL-045-3-11 70 62-AFL-010-3-11 50 40 30 20 60 62-AFL-016-3-11 50 62-AFL-010-3-11 40 30 62-AFL-030-3-11 20 62-AFL-060-3-11 62-AFL-060-3-11 10 10 62-AFL-045-3-11 0 0.1 0.2 0.5 1 2 10 5 20 0 0.1 50 0.2 0.5 1 5 10 62-AFC-030-3-11 62-AFC-030-3-11 70 62-AFC-016-3-11 60 Insertion Loss (dB) 62-AFC-016-3-11 62-AFC-010-3-11 50 40 30 20 60 50 62-AFC-010-3-11 40 30 62-AFC-045-3-11 62-AFC-060-3-11 20 62-AFC-060-3-11 10 10 62-AFC-045-3-11 0 0.1 0.2 0.5 1 2 10 5 20 0 0.1 50 0.2 0.5 1 62-AFL-030-5-11 20 50 20 50 70 62-AFL-016-5-11 62-AFL-010-5-11 Insertion Loss (dB) 62-AFL-016-5-11 40 30 62-AFL-045-5-11 20 62-AFL-030-5-11 60 62-AFL-010-5-11 50 40 30 20 62-AFL-060-5-11 62-AFL-060-5-11 10 10 0 0.1 0.2 0.5 1 2 5 10 20 62-AFL-045-5-11 0 0.1 50 0.2 0.5 1 2 5 10 Frequency (MHz) Frequency (MHz) 62-AFC-xxx-5-11 62-AFC-xxx-5-11 80 80 70 70 62-AFC-016-5-11 62-AFC-010-5-11 Insertion Loss (dB) Insertion Loss (dB) 10 80 50 60 5 62-AFL-xxx-5-11 62-AFL-xxx-5-11 80 Insertion Loss (dB) 2 Frequency (MHz) Frequency (MHz) 60 50 80 70 70 20 62-AFC-XXX-3-11 62-AFC-XXX-3-11 80 Insertion Loss (dB) 2 Frequency (MHz) Frequency (MHz) Power Line Filters 60 Insertion Loss (dB) Insertion Loss (dB) 62-AFL-016-3-11 50 40 30 62-AFC-060-5-11 20 62-AFC-045-5-11 62-AFC-030-5-11 62-AFC-016-5-11 10 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 20 62-AFC-030-5-11 60 62-AFC-010-5-11 50 40 30 20 62-AFC-045-5-11 10 50 0 0.1 62-AFC-060-5-11 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 61 Power Line Filters Single Stage 62-PPF/PQF/PRF Series Tested and found to be IAW VDE 0565 Part 3 Features ■ ■ ■ ■ ■ ■ ■ Low-cost plastic case Compact design requires minimal real estate space Suitable for products that must conform to FCC and FTZ regulations Wide variety of circuit and filtering options Good filtering characteristics for both normal mode and common mode Epoxy molded for reliability Operating temperature: -25°C to +85°C (including temperature rise, see graph on page 63) Applications ■ Power Line Filters ■ ■ ■ ■ Circuit Diagrams L1 62-PQF-020-5-11 62-PQF-020-5-12 62-PPF-020-5-11 62-PPF-020-5-12 62-PQF-030-5-11 62-PQF-030-5-12 62-PPF-030-5-11 62-PPF-030-5-12 62-PQF-060-5-11 62-PQF-060-5-12 62-PPF-060-5-11 62-PPF-060-5-12 62-PRF-010-5-11 62-PRF-010-5-12 62-PRF-020-5-11 62-PRF-020-5-12 62-PRF-030-5-11 62-PRF-030-5-12 Rated Voltage (@ 50/60Hz) CY CY CY CX R CY L1 L1 62-PRF* Series R CX CY CY * Bleeder Resistor is available only for 62-P(Q/R/P)F-XXX-X-12 Specifications Model R L1 62-PPF* Series Personal computers and peripherals Digital equipment Industrial equipment Vending machines Office equipment CX 62-PQF* Series Rated Current Leakage Current (Max.) Capacitance CY 2A 3A 0.50mA 250VAC 3300pF 6A 1A 2A 3A CX 0.1uF .22uF 0.1uF .22uF 0.1uF .22uF 0.1uF .22uF 0.1uF .22uF 0.1uF .22uF 0.1uF .22uF 0.1uF .22uF 0.1uF .22uF Inductance (L1) Temperature Rise (Max.) 15mH 8mH 30°C 2.1mH 486uH 181uH 97uH Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3 Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. (except 62-PRF-010-5-11) at rated current 62-PRF-010-5-11: 1.5V max. at rated current Weight: 62-PPF & PQF Series: 2.11 ounces (60 grams) 62-PRF Series: 1.76 ounces (50 grams) 62 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Power Line Filters Single Stage 62-PPF/PQF/PRF Series Temperature Characteristics Normal Mode 120 1 3 Filter 2 4 Current (%) 100 Oscillator 50Ω 80 50Ω 50Ω Level Meter 50Ω 60 40 62-PQF Series 80 20 70 20 30 40 50 60 70 Ambient Temperature (°C) 80 90 Fast-on tab #110 50 40 62-PQF-020-5-11 30 62-PQF-060-5-12 20 62-PQF-060-5-11 10 0 0.1 .786 (20) 0.2 1 0.5 .177 x .138 (4.5 x 3.5) 5 10 20 50 10 20 50 10 20 50 62-PPF Series 2.006 (51) 1.947 (49.5) .354 (9) 2 Frequency (MHz) 1.573 (40) .354 (9) Power Line Filters 0 Insertion Loss (dB) 62-PQF-020-5-12 60 80 1.265 (32) .590 (15) Dimensions in inches (mm) Also available with .250 Fast-ons Common Mode Insertion Loss (dB) 70 .904 (23) 60 50 62-PPF-020-5-12 40 62-PPF-020-5-11 30 62-PPF-060-5-12 20 62-PPF-060-5-11 10 1 3 Filter 2 4 Oscillator 50Ω 0 0.1 50Ω Level Meter 50Ω 0.2 1 0.5 2 5 Frequency (MHz) 62-PRF Series 62-P(P/Q/R)F Series 80 80 70 60 60 Insertion Loss (dB) Insertion Loss (dB) 62-P(Q/P)-060-5-11 70 50 40 30 62-P(Q/P)-020-5-11 20 50 62-PRF-010-5-11 40 62-PRF-010-5-12 30 62-PRF-030-5-12 20 62-P(Q/P)-030-5-11 62-PRF-030-5-11 10 0 0.1 10 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 63 Power Line Filters Single Stage Wire Leads 62-PML Series Tested and found to be IAW VDE 0565 Part 3 Features ■ ■ ■ ■ ■ ■ ■ Compact design requires minimal real estate space Suitable for products that must conform to FCC and FTZ regulations Excellent attenuation for high voltage impulse Metal case provides effective shielding Excellent filtering characteristics for both normal mode and common mode Structure provides effective shielding for noise generated externally and internally Operating temperature: -25°C to +85°C (including temperature rise, see graph on page 65) Circuit Diagram 1 3 CY L1 CX CX R Applications Power Line Filters ■ ■ ■ ■ ■ E Digital equipment Personal computers and peripherals Measuring instruments Medical equipment Factory automation equipment CY 4 2 Specifications Model Rated Voltage (@ 50/60Hz) 62-PML-015-3-11 Rated Current 1.5A 62-PML-015-5-11 62-PML-030-3-11 62-PML-030-5-11 62-PML-050-3-11 62-PML-050-5-11 62-PML-100-5-11 3A 250VAC 5A 10A Leakage Current (Max.) CY Capacitance 0.35mA 2200pF 0.50mA 3300pF 0.35mA 2200pF 0.50mA 3300pF 0.35mA 2200pF 0.50mA 3300pF 0.50mA 3300pF CX Inductance (L1) Temperature Rise (Max.) 10.0mH 4.3mH 30°C 0.1uF 2.4mH 2.2mH Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3 Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 62-PML-015 Series: 3.06 ounces (87 grams) 62-PML-030 Series: 3.17 ounces (90 grams) 62-PML-050 Series: 3.28 ounces (93 grams) Discharge time: 0.4 sec. max. 64 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Power Line Filters Single Stage Wire Leads 62-PML Series BK Temperature Characteristics WH G/Y 120 BK 1.219 (31) .786 (20) 1.966 (50) WH PVC Insulated wire AWG # 20 UL1015 100 .629 (16) 2 — .138 x .181 (3.5 x 4.6) .944 (24) 80 60 .395 (10) .395 (10) 5.112* (130) 40 5.112* (130) 20 * Custom lengths available upon request. Dimensions in inches (mm) 0 20 30 40 50 60 70 80 1.856 (47.2) 90 Power Line Filters Current (%) 1.573 (40) Ambient Temperature (°C) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 50Ω 50Ω Level Meter 50Ω 80 70 62-PML 90 40 30 62-PML-050-5-21 20 10 0 0.1 62-PML 80 62-PML-030-5-21 50 Insertion Loss (dB) Insertion Loss (dB) 62-PML-015-5-21 60 70 60 62-PML-050-5-11 50 40 62-PML-030-5-11 30 62-PML-015-5-11 20 0.2 0.5 1 2 5 10 20 50 10 Frequency (MHz) 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 65 Power Line Filters Single Stage Wire Leads for Medical Purpose Applications 12-PML & 12-PMF Series Features ■ ■ ■ ■ ■ ■ ■ ■ Compact design requires minimal real estate space Suitable for products that must conform to FCC and FTZ regulations Excellent attenuation for high voltage impulse Metal case provides effective shielding Excellent filtering characteristics for both normal mode and common mode Structure provides effective shielding for noise generated externally and internally Operating temperature: -25°C to +70°C Low leakage current Circuit Diagram Circuit 1 Circuit 2 Power Line Filters Applications ■ ■ ■ ■ ■ Digital equipment Personal computers and peripherals Measuring instruments Medical equipment Factory automation equipment Specifications Model Rated Voltage (@ 50/60Hz) Rated Current 12-PML-001-2-A 1A 12-PML-002-2-A 2A 12-PML-006-2-A 6A 12-PML-010-2-A 12-PMF-001-2-B 120/250VAC 10A 1A 12-PMF-002-2-B 2A 12-PMF-006-2-B 6A 12-PML-001-2-C 1A Leakage Current (Max.) Circuit Diagram Figure 1 A 5uA Temperature Rise (Max.) 30°C 2 B 1 C Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3 Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Discharge time: 0.4 sec. max. 66 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Power Line Filters Single Stage Wire Leads for Medical Purpose Applications 12-PML & 12-PMF Series Figure A Figure C .31 (8) .13 (3.5) X .17 (4.5) SLOT (2 PLACES) .13 (3.5) X .17 (4.5) SLOT (2 PLACES) .94 (24) 1.5 (39) 1.9 (49) 1.2 (30) 1.25 (32) 1.6 (42) 1.9 (48) 1.7 (44) .78 (20) .78 (20) Figure B .14 (3.8) (2X) 1.2 (30) 1.7 (44) .79 (20) 2.2 (56) 2.4 (61) Common Mode Power Line Filters Dimensions in inches (mm) Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 12-PML-001;-002;-006;-010 50Ω 50Ω Level Meter 50Ω 12-PML-001;-002;-006;-010 80 80 70 70 12-PML-002-2-A 12-PML-006-2-A 60 12-PML-001-2-A Insertion Loss (dB) Insertion Loss (dB) 12-PML-001-2-A 12-PML-006-2-A 50 40 30 20 12-PML-002-2-A 10 0 0.1 50 40 30 20 12-PML-010-2-A 10 12-PML-010-2-A 0.2 60 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 2 Frequency (MHz) 70 70 12-PMF-001-2-B 12-PMF-002-2-B 50 40 30 20 12-PMF-006-2-B 10 0 0.1 0.5 1 2 5 Frequency (MHz) 10 12-PMF-001-2-B 20 50 20 50 12-PMF-002-2-B 60 50 11-PML-001-2-C 40 30 20 12-PMF-006-2-B 10 11-PML-001-2-C 0.2 10 12-PMF-001;-002;-006;-010 80 Insertion Loss (dB) Insertion Loss (dB) 12-PMF-001;-002;-006;-010 80 60 5 Frequency (MHz) 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 67 Power Line Filters Single Stage 62-LMF & LMB Series Tested and found to be IAW VDE 0565 Part 3 Features ■ ■ ■ ■ ■ ■ ■ Space saving, compact designs Suitable for products that must conform to FCC and FTZ regulations Excellent filtering characteristics for both normal mode and common mode Structure provides effective shielding for noise generated externally and internally Metal case provides effective shielding Rugged construction Operating temperature: -25°C to +85°C (including temperature rise, see graph on page 69) Circuit Diagram CY 1 Power Line Filters ■ ■ ■ CX CX R Applications ■ 3 L1 CY Digital equipment Office automation equipment, such as copy and fax machines Computers and peripherals Instrumentation and controls E 4 2 Specifications Model* Rated Voltage (@ 50/60Hz) 62-LMB-030-5-11 Rated Current Leakage Current (Max.) Capacitance CX Inductance (L1) 3A 0.1uF 14mH 5A 0.1uF & .22uF 7.0mH 8A .22uF 4.2mH 10A .33uF 2.2mH CY Temperature Rise (Max.) 62-LMF-030-5-11 62-LMB-050-5-11 62-LMF-050-5-11 62-LMB-080-5-11 62-LMF-080-5-11 62-LMB-100-5-11 250VAC 0.50mA 62-LMF-100-5-11 Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Discharge time: 0.4 sec. max. Weight: 5.3 ounces (150 grams) 68 45°C 3300pF *62-LMF - designates Fast-on terminals 62-LMB - designates Bolt-in terminals 62-LML - wire lead in/outputs also available SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Temperature Characteristics 120 100 Current (%) Power Line Filters Single Stage 80 60 40 20 62-LMF & LMB Series 0 30 40 50 60 70 Ambient Temperature (°C) 80 90 62-LMF 62-LMB .708 (18.0) 20 1.10 (28.0) 1.97 (50.0) .66 (16.8) .66 (16.8) .255 (6.5) .61 (15.5) 1.10 (28.0) .708 (18.0) .61 (15.5) 1.97 (50.0) 2 - ø4.8 .255 (6.5) 5-M4 2.39 (60.7± 0.5) 1.97 (50.0) 1.22 (31.0) 2.79 (70.9) .61 (15.5) 1.97 (50.0) 2.79 (70.9) .61 (15.5) Fast-on Tabs #250 .031 (0.8) t 2 - ø .188 (4.8) Dimensions in inches (mm) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω Power Line Filters 1.22 (31.0) 2.39 (60.7± 0.5) 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 62-LMF & LMB 50Ω 50Ω Level Meter 50Ω 62-LMF & LMB 90 90 80 80 70 62-LM-030-5-11 Insertion Loss (dB) Insertion Loss (dB) 62-LM-030-5-11 62-LM-050-5-11 60 50 40 30 62-LM-100-5-11 20 0.5 60 50 40 62-LM-100-5-11 30 62-LM-080-5-11 10 10 0.2 70 20 62-LM-080-5-11 0 0.1 62-LM-050-5-11 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 69 Power Line Filters Single Stage 62-PMF & PMB Series Tested and found to be IAW VDE 0565 Part 3 Features ■ ■ ■ ■ ■ ■ ■ ■ Space-saving, compact designs Suitable for products that must conform to FCC regulations Excellent attenuation for high voltage impulse Metal case provides effective EMI shielding Excellent filtering characteristics for both normal mode and common mode Epoxy molded for internal component reliability Structure provides effective shielding for noise generated externally and internally Operating temperature: -25°C to +85°C (including temperature rise, see graph on page 71) Circuit Diagram CY 1 3 L1 CX CX R CY E Applications Power Line Filters ■ ■ ■ ■ ■ ■ ■ ■ ■ 4 2 Digital equipment Computers and peripherals Measuring instruments Medical equipment Equipment requiring very high impulse attenuation Factory automation equipment Industrial equipment such as UPS, inverters and converters Telecommunications equipment Office automation equipment, such as copy and fax machines Specifications Model* Rated Voltage (@ 50/60Hz) 62-PMB-050-5-11 Rated Current Leakage Current (Max.) Capacitance CX Inductance (L1) 5A 0.1uF 14mH 8A .1uF & .22uF 7.0mH .22uF 4.2mH CY Temperature Rise (Max.) 62-PMF-050-5-11 62-PMB-080-5-11 62-PMF-080-5-11 62-PMB-100-5-12 62-PMF-100-5-12 62-PMB-150-5-13 62-PMF-150-5-13 250VAC 10A 2.2mH 35°C 1.8mH 45°C** .33uF 20A Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. Discharge time: 0.4 sec. max. Weight: 8.82 ounces ( 250 grams) 70 3300pF 15A 62-PMB-200-5-13 62-PMF-200-5-13 0.50mA 30°C * PMF - designates Fast-on terminals PMB - designates Bolt-in terminals ** The temperature rise of 20 amp units can be decreased to 30°C by mounting on 200 X 200 x 1.0(mm) steel chassis SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Power Line Filters Single Stage 62-PMF & PMB Series 62-PMF 3.291 (83.7) B C Fast-on tab #250 2.937 (74.7) Temperature Characteristics 1.258 (32) 120 2 — .197 (5) .610 (15.5) .315 (8) A 62-PMB 80 3.291 (83.7) B 2.937 (74.7) 5 — .157 (M4) 60 C 2 — .197 (5) 1.258 (32) 1.998 (50.8) 40 MODEL 30 40 50 60 70 Ambient Temperature (°C) 80 90 Common Mode B C 1.490 .944 .433 (38) (24) (11) 62-PMF/PMB-050-080 1.258 .786 (32) (20) 0 (0) Dimensions in inches (mm) 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 62-PMB-050-6 50Ω 50Ω Level Meter 50Ω 62-PMB-050-6 R2 R1 S1 Filter S2 T1 T2 50Ω Level Meter Oscillator 50Ω 90 90 80 80 50Ω 50Ω 50Ω R2 R1 S1 Filter S2 T1 T2 Oscillator 50Ω Insertion Loss (dB) 60 50 40 62-PMB-100-5-12 30 62-PMB-150-5-13 20 62-PMF-050-5-11 70 60 50 40 62-PMF-150-5-13 30 20 62-PMB-200-5-13 10 50Ω Level Meter 62-PMB-200-5-13 62-PMB-050-5-11 62-PMB-080-5-11 0 0.1 A 62-PMF/PMB-100-200 Normal Mode 1 3 Filter 2 4 Oscillator 50Ω .315 (8) A 50Ω 20 50Ω 0 70 .649 (16.5) 2.497 (63.5) Power Line Filters .649 (16.5) 20 Insertion Loss (dB) .610 (15.5) 2.497 (63.5) 50Ω Current (%) 100 1.998 (50.8) 62-PMF-080-5-11 10 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 62-PMF-100-5-12 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 71 Power Line Filters Single Stage 12-PMF Series Features ■ ■ ■ ■ ■ ■ ■ ■ Space-saving, compact designs Suitable for products that must conform to FCC regulations Excellent attenuation for high voltage impulse Metal case provides effective EMI shielding Excellent filtering characteristics for both normal mode and common mode Epoxy molded for internal component reliability Structure provides effective shielding for noise generated externally and internally Operating temperature: -40°C to +85°C Circuit Diagram Circuit 1 Circuit 2 Circuit 3 Circuit 4 Circuit 5 Circuit 6 Applications ■ Power Line Filters ■ ■ ■ ■ ■ ■ ■ ■ Digital equipment Computers and peripherals Measuring instruments Medical equipment Equipment requiring very high impulse attenuation Factory automation equipment Industrial equipment such as UPS, inverters and converters Telecommunications equipment Office automation equipment, such as copy and fax machines Specifications Model Rated Voltage (@ 50/60Hz) Rated Current Leakage Current (Max.) Circuit Diagram Figure 12-PMF-001-5-A 1A 1 A 12-PMF-002-5-B 2A 2 B 4 A 2 B 12-PMF-003-5-A 3A 12-PMF-003-5-B 12-PMF-006-5-A 6A 12-PMF-006-5-C 12-PMF-006-5-D 12-PMF-010-5-A 12-PMF-010-5-C 12-PMF-015-5-C 12-PMF-015-5-E 120/250VAC 10A A 1 C 6 D 2 A 3 15A 20A 12-PMF-020-5-E 30°C C E 5 12-PMF-020-5-C 12-PMF-020-5-D 0.5mA 4 Temperature Rise (Max.) C D E Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. Discharge time: 0.4 sec. max. 72 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Power Line Filters Single Stage 12-PMF Series Figure A Figure B .14 (3.8) 2 .34 (8.8) 1.2 (30) 2.4 1.8 (62) (46) 2.1 (54) 1.7 (44) 2.2 (56) .78 (20) 3.2 (81) 1.25 (32) 2.4 (62) .86 (22) Figure D Figure C Figure E .41 (10.5) 2 .17 (8.8) 2- 1.7 (4.5) (2X) .18 (4.8) 2.0 (52) 2.0 (52) 2.4 (63) 1.9 2.3 2.8 (50) (60) (10.5) 1.4 (37) 2.5 3.3 (64) (85) 2.9 (74) 3.2 (82) Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 12-PMF-001;-002;-003;-006 12-PMF-006-5-C 12-PMF-001-5-A 70 12-PMF-001-5-A 12-PMF-006-5-A 12-PMF-002-5-B 12-PMF-003-5-B 12-PMF-006-5-A 40 12-PMF-003-5-A 12-PMF-006-5-C 30 20 12-PMF-006-5-D 60 12-PMF-006-5-D 50 40 30 12-PMF-003-5-B 20 12-PMF-003-5-A 10 10 0 0.1 12-PMF-002-5-B 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 Frequency (MHz) 12-PMF-001;-002;-003;-006 12-PMF-006-5-A 40 12-PMF-003-5-A 12-PMF-006-5-C 30 20 Insertion Loss (dB) Insertion Loss (dB) 12-PMF-003-5-B 50 12-PMF-015-5-E 60 12-PMF-020-5-C 50 40 12-PMF-010-5-A 30 20 12-PMF-020-5-D 12-PMF-020-5-E 12-PMF-006-5-D 10 10 0.5 20 12-PMF-010-5-C 12-PMF-002-5-B 0.2 10 70 12-PMF-001-5-A 0 0.1 5 12-PMF-010;-015;-020 80 70 50 2 Frequency (MHz) 80 60 50Ω Level Meter 50Ω 80 Insertion Loss (dB) Insertion Loss (dB) 50 50Ω 12-PMF-001;-002;-003;-006 80 70 1.4 (36) 3.1 (80) Common Mode 60 2.0 (51) 1.1 (28) 2.9 (74) Power Line Filters 1.7 (44) Dimensions in inches (mm) 1 2 5 Frequency (MHz) 10 20 50 0 0.1 12-PMF-015-5-C 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 73 Power Line Filters Single Stage - Higher Current 62-PMB Series Features ■ ■ ■ ■ ■ ■ ■ ■ ■ Power Line Filters ■ Space-saving, compact designs Suitable for products that must conform to FCC regulations Excellent attenuation for high voltage impulse Metal case provides effective shielding Excellent filtering characteristics for both normal mode and common mode Epoxy molded for internal component reliability Structure provides effective shielding for noise generated externally and internally Safety agency approvals pending Designed to be in accordance with VDE 0565 Part 3 Operating temperature: -25°C to +85°C (including temperature rise) Circuit Diagram 3 1 L1 CX CY CX R E CY L1 4 2 Applications ■ ■ ■ ■ ■ ■ ■ ■ ■ Digital equipment Computers and peripherals Measuring instruments Medical equipment Equipment requiring very high impulse attenuation Factory automation equipment Industrial equipment such as UPS, inverters and converters Telecommunications equipment Office automation equipment, such as copy and fax machines Specifications Model Rated Voltage (@ 50/60Hz) 62-PMB-300-5-14 Rated Current CY Capacitance CX 0.50mA 3300pF .47uF 40A Inductance (L1) Temperature Rise (Max.) 1.6mH 30A 250VAC 62-PMB-400-5-14 Leakage Current (Max.) 45°C 0.8mH Note: Test voltage: 1500VAC one minute, line to earth Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. Discharge time: 0.4 sec. max. Weight: 8.82 ounces (250 grams) 74 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Power Line Filters Single Stage - Higher Current 62-PMB Series 62-PMB-300-5-14 and 62-PMB-400-5-14 4.13 (105) 3.74 (95±.08) 3.15 (80) 0.511 (13.0) 3.70 (94) 3.85 (98) 1.022 (26.0) 5.591 (142.00) 2.049 (52.0) Dimensions in inches (mm) Common Mode Normal Mode 1 3 1 4 2 50 ohm LEVEL METER 50 ohm 90 90 80 80 70 70 60 62-PMB-400-5-14 40 30 20 10 0 0.1 50 ohm LEVEL METER 50 ohm 60 50 62-PMB-300-5-14 40 30 20 62-PMB-300-5-14 4 OSCILLATOR 50 ohm Insertion Loss (dB) Insertion Loss (dB) 50 ohm 50 3 FILTER FILTER 2 OSCILLATOR 50 ohm Power Line Filters 3.03 (77±0.5) 62-PMB-400-5-14 10 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 75 Power Line Filters Single Stage - Higher Current 12-PMB Series Features ■ ■ ■ ■ ■ ■ ■ ■ ■ Space-saving, compact designs Suitable for products that must conform to FCC regulations Excellent attenuation for high voltage impulse Metal case provides effective shielding Excellent filtering characteristics for both normal mode and common mode Epoxy molded for internal component reliability Structure provides effective shielding for noise generated externally and internally Designed to be in accordance with VDE 0565 Part 3 Operating temperature: -40°C to +85°C Circuit Diagram Power Line Filters ■ ■ ■ ■ ■ ■ ■ ■ L1 CX CY CX R L1 Applications ■ 3 1 E CY 4 2 Digital equipment Computers and peripherals Measuring instruments Medical equipment Equipment requiring very high impulse attenuation Factory automation equipment Industrial equipment such as UPS, inverters and converters Telecommunications equipment Office automation equipment, such as copy and fax machines Specifications Model Rated Voltage (@ 50/60Hz) Rated Current 12-PMB-025-5-A 25A 12-PMB-030-5-A 30A 12-PMB-035-5-B 12-PMB-050-5-B 120/250VAC Leakage Current (Max.) 100A 120A Temperature Rise (Max.) A 1 50A 12-PMB-120-8-C Figure 0.5mA 35A 12-PMB-100-8-C Circuit Diagram 1.0mA B 30°C C Note: Test voltage: 1500VAC one minute, line to earth Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. Discharge time: 0.4 sec. max. Weight: 8.82 ounces (250 grams) 76 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Power Line Filters Single Stage - Higher Current 12-PMB Series Figure A 1M4 STUD (4X) Figure B .17 (4.5) ±.007 (2X) M4 THREAD (10X) Figure C 0.2 (6.3) 0.5 (4.5) 2.0 (24) ±.03 2.0 (52) 0.16 (4.2) X 0.25 (6.4) (2X) M8 THREAD (4X) 4.3 4.5 5.1 (110) (115) (130) 3.3 3.7 4.1 (84) (95) (105) 0.2 (6) ±.03 2.5 (64) MAX 2.9 (75) ±.01 0.8 (22) ±.03 1.4 (37) MAX 3.9 (101) MAX 1.9 (50) 2.0 (51) 3.9 (98.5) 1.5 (38.5) 3.1 (80) 4.7 (120) 7.0 (180) 5.3 (135) Common Mode Power Line Filters Dimensions in inches (mm) Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 50Ω 50Ω Level Meter 50Ω 12-PMB-025;-030;-035 12-PMB-025;-030;-035 80 80 70 70 60 Insertion Loss (dB) Insertion Loss (dB) 12-PMB-035-5-B 12-PMB-025-5-A 50 40 30 12-PMB-035-5-B 20 60 50 12-PMB-025-5-A 40 12-PMB-030-5-A 30 20 12-PMB-030-5-A 10 10 0 0.1 0.2 0.5 1 2 10 5 20 0 0.1 50 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) Frequency (MHz) 12-PMB-050;-100;-120 12-PMB-050;-100;-120 80 80 70 70 12-PMB-050-5-B Insertion Loss (dB) Insertion Loss (dB) 12-PMB-100-8-C 60 50 40 30 12-PMB-050-5-B 20 60 50 12-PMB-120-8-C 40 12-PMB-100-8-C 30 20 12-PMB-120-8-C 10 0 0.1 10 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 77 Power Line Filters DC - Higher Current 12-PMF & 12 PMB DC Series Features ■ ■ ■ ■ ■ ■ ■ ■ ■ Space-saving, compact designs Suitable for products that must conform to FCC regulations Excellent attenuation for high voltage impulse Metal case provides effective shielding Excellent filtering characteristics for both normal mode and common mode Epoxy molded for internal component reliability Structure provides effective shielding for noise generated externally and internally Designed to be in accordance with VDE 0565 Part 3 Operating temperature: -40°C to +85°C Circuit Diagram Circuit 1 Applications ■ Power Line Filters ■ ■ ■ ■ ■ ■ Circuit 2 Digital equipment Computers and peripherals Measuring instruments Equipment requiring very high impulse attenuation Factory automation equipment Industrial equipment such as UPS, inverters and converters Telecommunications equipment Specifications Model 12-PMF-006-DC-C 12-PMF-010-DC-C 12-PMF-015-DC-C 12-PMF-020-DC-C 12-PMF-025-DC-D 12-PMB-025-DC-F 12-PMB-030-DC-F 12-PMB-035-DC-F 12-PMB-040-DC-F 12-PMB-040-DC-B 12-PMB-050-DC-B 12-PMB-060-DC-B 12-PMB-080-DC-G 12-PMB-080-DC-C 12-PMB-100-DC-C 12-PMB-120-DC-C 12-PMB-140-DC-C 12-PMB-180-DC-E 12-PMB-200-DC-E 12-PMB-260-DC-E Rated Voltage (@ 50/60Hz) Rated Current Circuit Diagram 6A 10A 15A 20A 30A 35A Figure Temperature Rise (Max.) A B 25A 1 C 40A 48/250 VDC 50A 60A 80A 100A 120A 140A 180A 200A 260A Note: Test voltage: 1500VAC one minute, line to earth Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. 78 Circuit 3 D 2 3 2 30°C E F G Discharge time: 0.4 sec. max. Weight: 8.82 ounces (250 grams) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Figure A Power Line Filters DC - Higher Current 12-PMF & 12-PMB DC Series Figure B Figure C Figure D Figure E Figure F Figure G Power Line Filters 1.9 (50) ±.003 Dimensions in inches (mm) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 12-PMF-006;-010;-015;-020;-025 80 12-PMF-006;-010;-015;-020;-025 12-PMF-025-DC-D 70 60 Insertion Loss (dB) Insertion Loss (dB) 12-PMF-010-DC-C 50 12-PMF-025-DC-D 40 30 12-PMF-015-DC-C 20 12-PMF-020-DC-C 10 60 12-PMF-020-DC-C 50 12-PMF-010-DC-C 40 12-PMF-015-DC-C 30 12-PMF-006-DC-C 20 10 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 Frequency (MHz) 12-PMB-080-DC-G 12-PMB-080-DC-C 12-PMB-025-DC-F 12-PMB-030-DC-F 12-PMB-035-DC-F 12-PMB-040-DC-F 20 50 40 12-PMB-180-DC-E 12-PMB-200-DC-E 12-PMB-260-DC-E 30 20 12-PMB-040-DC-B 12-PMB-050-DC-B 12-PMB-060-DC-B 12-PMB-100-DC-C 12-PMB-120-DC-C 12-PMB-140-DC-C 10 0.2 0.5 1 2 5 Frequency (MHz) 70 Insertion Loss (dB) Insertion Loss (dB) 10 80 50 0 0.1 5 12-PMB-025; thru -260 12-PMB-025; thru -260 60 2 Frequency (MHz) 80 70 50Ω Level Meter 50Ω 80 12-PMF-006-DC-C 70 0 0.1 50Ω 10 20 60 40 12-PMB-080-DC-G 12-PMB-080-DC-C 30 20 10 50 12-PMB-025-DC-F 12-PMB-030-DC-F 12-PMB-035-DC-F 12-PMB-040-DC-F 50 0 0.1 12-PMB-180-DC-E 12-PMB-200-DC-E 12-PMB-260-DC-E 0.2 0.5 12-PMB-040-DC-B 12-PMB-050-DC-B 12-PMB-060-DC-B 1 2 12-PMB-100-DC-C 12-PMB-120-DC-C 12-PMB-140-DC-C 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 79 Power Line Filters Dual Stage 62-MMF Series Features ■ ■ ■ ■ ■ ■ ■ Suitable for products that must conform to FCC regulations Excellent attenuation for high voltage impulse Metal case provides effective EMI shielding Two stages for excellent filtering characteristics Epoxy molded for reliability Structure provides effective shielding for noise generated both externally and internally Operating temperature: -25°C to +85°C (including temperature rise, see graph on page 81) Circuit Diagram 62-MMF-XXX-7-11 1 L1 CX R Applications ■ Power Line Filters ■ ■ ■ ■ CX CY CX CY Digital equipment Personal computers and peripherals Measuring instruments and medical equipment Telecommunications equipment Equipment requiring very high noise attenuation 3 L1 CY CY 2 E 4 Specifications Model Rated Voltage (@ 50/60Hz) Rated Current Leakage Current (Max.) CY1 Capacitance CY2 CX Inductance (L1) (2X) Temperature Rise (Max.) 62-MMF-030-7-11 250VAC 3A .7mA 3300pF 1000pF 0.1uF 3.7mH 30°C 62-MMF-050-7-11 250VAC 5A .7mA 3300pF 1000pF 0.1uF 2.9mH 30°C Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3 Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Leakage current: 0.7 mA max. Voltage drop: 1V max. Discharge time: 0.4 sec. max. Weight: 6.0 ounces (170 grams) 80 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Power Line Filters Dual Stage 62-MMF Series Temperature Characteristics 3.291 (83.7) 120 .786 (20) .315 (8) Fast-on tab #250 2.937 (74.7) Current (%) 100 80 .315 (8) 2 – .197 (5) 1.258 (32) 1.998 (50.8) 60 .610 (15.5) 40 .610 (15.5) 2.497 (63.5) 1.258 (32) 20 Dimensions in inches (mm) 20 30 40 50 60 70 80 90 Power Line Filters 0 Ambient Temperature (°C) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 90 80 80 70 70 60 62-MMF-050-7-11 50 62-MMF-030-7-11 40 30 20 60 62-MMF-050-7-11 50 62-MMF-030-7-11 40 30 20 10 0 0.1 50Ω Level Meter 50Ω 62-MMF 90 Insertion Loss (dB) Insertion Loss (dB) 62-MMF 50Ω 10 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 81 Power Line Filters Dual Stage 12-MMF & 12-MMB Series Features ■ Suitable for products that must conform to FCC regulations Excellent attenuation for high voltage impulse Metal case provides effective EMI shielding Two stages for excellent filtering characteristics Structure provides effective shielding for noise generated both externally and internally Operating temperature: -40°C to +85°C ■ High performance ■ Low leakage current ■ ■ ■ ■ ■ Circuit Diagram Circuit 1 Applications ■ Power Line Filters ■ ■ ■ ■ ■ Circuit 2 Digital equipment Switching power supplies Personal computers and peripherals Measuring instruments and medical equipment Telecommunications equipment Equipment requiring very high noise attenuation Circuit 3 Specifications Model 12-MMF-002-5-F 12-MMF-003-5-F 12-MMF-003-5-A 12-MMF-006-5-F 12-MMF-006-5-G 12-MMF-008-5-B 12-MMF-010-5-F 12-MMF-010-5-G 12-MMF-010-5-B 12-MMF-012-5-B 12-MMB-015-5-E 12-MMB-020-5-F 12-MMB-030-5-D 12-MMB-050-5-C Rated Voltage (@ 50/60Hz) Rated Current Leakage Current (Max.) 2A 1 3A 120/250VAC Circuit Diagram 3 Figure A B C 6A B 8A D 10A 0.5mA B 2 12A 15A 20A 30A 50A Temperature Rise (Max.) 30°C D E D F G Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3 Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Leakage current: 0.7 mA max. Voltage drop: 1V max. Discharge time: 0.4 sec. max. 82 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Figure C Power Line Filters Dual Stage 2.12 (54) 1.81 2.44 (46) (62) 12-MMF & 12-MMB Series Figure A Ø .15 (3.8) (2X) 1.26 (32) .87 (22) 2.44 (62) Figure B Figure D Ø .25 (6.4) (2X) 2.00 (51) 2.24 (57) 2.00 ± .02 (75 ± .5) 3.35 (85) MAX Figure E Figure F M4 THREAD (5X) M4 STUD (7X) 2.90 (73) 2.42 (87) 4.01 (102) 1.77 (45) Figure G .117 (4.5) X .25 (6.3) SLOT (4X) M4 THREAD .21 (5.4) X .37 (9.4) HOLE (4X) M6 THREAD (4X) 3.30 3.74 4.13 (84) (95) (105) .71 (18) 1.50 (38) 6.30 (160) 7.24 (184) 7.95 (202) 2.30 (58) 1.51 (38.5) 3.93 4.52 5.12 (100) (115) (130) 2.01 (51) 3.88 (98.5) 5.31 (135) 1.97 (50) 3.15 (80) 4.72 (120) 7.09 (180) Dimensions in inches (mm) Common Mode Power Line Filters 2.40 ± .007 (60 ± .2) 3.38 1.65 (86) (42) Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 12-MMF-002;-003;-006;-008 50Ω 50Ω Level Meter 50Ω 12-MMF-002;-003;-006;-008 80 80 70 70 60 Insertion Loss (dB) Insertion Loss (dB) 12-MMF-006-5-G 12-MMF-002-5-F 50 12-MMF-003-5-F 40 12-MMF-006-5-F 12-MMF-006-5-G 30 20 12-MMF-008-5-B 60 12-MMF-002-5-F 50 12-MMF-006-5-F 12-MMF-003-5-F 40 12-MMF-008-5-B 30 20 12-MMF-003-5-A 10 10 0 0.01 12-MMF-003-5-A 0.05 0.15 0.45 1 2 5 10 20 0 0.01 50 0.05 0.15 0.45 1 Frequency (MHz) 2 5 10 20 50 Frequency (MHz) 12-MMF-010;-012;-015;-020;-030;-050 12-MMF-010;-012;015;-020;-030;-050 80 80 70 70 60 12-MMB-030-5-D 50 12-MMB-050-5-C 40 12-MMB-015-5-E 12-MMF-010-5-F 12-MMF-010-5-G 12-MMB-020-5-F 12-MMF-010-5-B 12-MMF-012-5-B 30 20 10 0 0.01 0.05 0.15 0.45 1 2 5 Frequency (MHz) 10 20 50 Insertion Loss (dB) Insertion Loss (dB) 12-MMB-050-5-C 60 50 40 12-MMB-030-5-D 30 12-MMF-010-5-F 12-MMF-010-5-G 12-MMF-010-5-B 12-MMF-012-5-B 12-MMB-015-5-E 12-MMB-020-5-F 20 10 0 0.01 0.05 0.15 0.45 1 2 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 83 Power Line Filters Dual Stage 12-MMF & 12-MMB Series Features ■ Suitable for products that must conform to FCC regulations Excellent attenuation for high voltage impulse Metal case provides effective EMI shielding Two stages for excellent filtering characteristics Structure provides effective shielding for noise generated both externally and internally Operating temperature: -40°C to +85°C ■ High performance ■ ■ ■ ■ ■ Circuit Diagram Circuit 1 Applications ■ ■ Power Line Filters ■ ■ ■ Digital equipment Personal computers and peripherals Measuring instruments and medical equipment Telecommunications equipment Equipment requiring very high noise attenuation Circuit 2 Specifications Model 12-MMF-003-11-F 12-MMF-006-11-F 12-MMF-010-11-F 12-MMB-012-11-A 12-MMB-015-11-G 12-MMB-020-11-D 12-MMB-030-11-D 12-MMB-040-11-B 12-MMB-040-11-E 12-MMB-050-11-H Rated Voltage (@ 50/60Hz) 120/250VAC Rated Current 3A 6A 10A 12A 15A 20A 30A Leakage Current (Max.) 1.5mA 40A 50A Circuit Diagram Figure 1 A 2 B C 1 2 1 Temperature Rise (Max.) 30°C B D E F Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3 Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Leakage current: 0.7 mA max. Voltage drop: 1V max. Discharge time: 0.4 sec. max. Weight: 6.0 ounces (170 grams) 84 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Power Line Filters Dual Stage 12-MMF & 12-MMB Series Figure C Figure B Ø .18 ± .007 (2X) (4.5 ± 0.2) 3.74 1.73 3.33 ± .02 ± .04 MAX (44 ± 1) (84.5) (95 ± 0.5) .75 ± .04 (19 ± 1) 1.53 MAX (39) Figure D 4.13 MAX (105) 2.24 (57) 2.01 ± .02 (51 ± 0.5) 3.90 MAX (99) 6.20 MAX (157) Figure F .25 (6.4) x .37(9.4) SLOT (4X) 2.28 (58) 1.77 (45) .95 (24.1) 2.24 (57) .35 (9) .90 (23) 8.66 (220) 9.57 (243) 10.27 (261) 3.54 (90) .165 (4.2) X .25 (6.4) (4X) M8 THREAD (4X) .177 (4.5) X .25 (6.5) SLOT (2X) 3.54 5.90 (90) (150) 2.90 (73) 3.42 (87) 4.30 (109) 1.80 (45) Figure E M6 THREAD (5X) M4 THREAD (4X) 1.77 (45) 3.93 4.53 5.12 (100) (115) (130) 2.91 (74) 3.66 (93) 4.01 (102) 1.97 (50) 3.14 (80) 4.72 (120) 7.08 (180) Dimensions in inches (mm) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 50Ω 50Ω Level Meter 50Ω 12-MMF-003;-006;-010;-012;-015 12-MMF-003;-006;-010;-012;-015 120 120 12-MMF-003-11-F 12-MMF-012-11-A 105 105 12-MMF-003-11-F 12-MMF-012-11-A 90 Insertion Loss (dB) Insertion Loss (dB) Power Line Filters Figure A 75 60 12-MMF-006-11-F 45 12-MMF-010-11-F 30 15 0 0.1 90 75 60 45 12-MMF-015-11-G 30 12-MMF-006-11-F 12-MMF-015-11-G 15 12-MMF-010-11-F 0 0.2 0.5 1 2 5 10 20 0.1 50 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) Frequency (MHz) 12-MMF-020;-030;-040;-050 12-MMF-020;-030;-040;-050 120 120 12-MMF-040-11-B 12-MMF-020-11-D 105 105 90 90 Insertion Loss (dB) Insertion Loss (dB) 12-MMF-040-11-B 75 60 45 30 75 60 45 12-MMF-050-11-H 30 12-MMF-040-11-E 12-MMF-040-11-E 15 0.2 0.5 1 12-MMF-020-11-D 12-MMF-050-11-H 0 0.1 12-MMF-030-11-D 15 12-MMF-030-11-D 2 5 Frequency (MHz) 10 0 20 50 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 85 Power Line Filters Dual Stage 12-MMF & 12-MMB Series Features ■ ■ ■ ■ ■ ■ ■ Suitable for products that must conform to FCC regulations Excellent attenuation for high voltage impulse Metal case provides effective EMI shielding Two stages for excellent filtering characteristics Epoxy molded for reliability Structure provides effective shielding for noise generated both externally and internally Operating temperature: -25°C to +85°C Circuit Diagram Circuit 1 Applications ■ ■ Power Line Filters ■ ■ ■ Digital equipment Personal computers and peripherals Measuring instruments and medical equipment Telecommunications equipment Equipment requiring very high noise attenuation Circuit 2 Circuit 3 Specifications Model 12-MMF-001-5-F 12-MMF-003-5-G 12-MMF-003-2-G 12-MMF-006-5-G 12-MMB-010-5-D 12-MMB-015-5-E 12-MMB-020-5-E 12-MMB-030-5-E Rated Voltage (@ 50/60Hz) Rated Current 1A 3A 120/250VAC 6A 10A 15A 20A 30A Leakage Current (Max.) Circuit Diagram 0.5mA 3 5uA 1 Figure A B C 0.5mA Temperature Rise (Max.) 30°C 2 D Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3 Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Leakage current: 0.7 mA max. Voltage drop: 1V max. Discharge time: 0.4 sec. max. Weight: 6.0 ounces (170 grams) 86 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Power Line Filters Dual Stage 12-MMF & 12-MMB Series Figure B Figure A 2.01 (51) 2.52 (64) 2.95 (75) 3.70 (94) 1.06 (27) M4 THREAD (5X) Figure D .25 (6.4) .37 (9.4) HOLE (4X) M4 STUD (7X) 3.33 1.73 ± .03 (84.5) (44 ± 1) MAX 3.74 ± .02 (95 ± 0.5) 4.13 MAX. (64) 0.75 ± .03 (19 ± 1) 2.36 ± .007 (60 ± .2) 3.38 1.65 (86) (42) 2.01 ± .02 (51 ± .05) 1.52 (39) MAX 2.28 (58) 3.15 (99) MAX 5.31 (135) MAX Dimensions in inches (mm) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 7.09 (180) 7.24 (184) 7.95 (202) .71 (18) 1.50 (38) 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 12-MMF-001;-003;-006 50Ω 12-MMF-001;-003;-006 120 120 12-MMF-006-5-G 12-MMF-006-5-G 105 105 12-MMF-003-2-G 90 Insertion Loss (dB) Insertion Loss (dB) 12-MMF-003-5-G 75 60 45 30 12-MMF-003-2-G 12-MMF-001-5-F 15 0 0.1 90 75 60 12-MMF-003-5-G 45 30 12-MMF-001-5-F 15 0 0.2 0.5 1 2 10 5 20 0.1 50 0.2 0.5 1 Frequency (MHz) 2 5 10 20 50 Frequency (MHz) 12-MMB-010;-015;-020;-030 12-MMB-010;-015;-020;-030 120 120 12-MMB-010-5-D 12-MMB-015-5-E 105 105 12-MMB-020-5-E 90 Insertion Loss (dB) Insertion Loss (dB) 50Ω Level Meter 50Ω Power Line Filters Figure C 75 60 12-MMB-030-5-E 45 30 12-MMB-010-5-D 12-MMB-015-5-E 12-MMB-020-5-E 90 75 12-MMB-030-5-E 60 45 30 15 15 0 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 87 Power Line Filters Three Phase Low Current/High Performance 62-PMB/63-PMF Series Features ■ ■ ■ ■ ■ ■ ■ ■ ■ Excellent attenuation for high voltage impulse Effective for both balanced and unbalanced three-phase loads Metal case provides effective EMI shielding Epoxy molded for internal component reliability Compact and economical Excellent filtering characteristics for both normal and common mode Various current ratings available: 3, 5, 8 and 16 Amps Safety agency approvals pending Operating temperature: -25°C to +85°C (including temperature rise, see graph on page 89) Power Line Filters ■ ■ ■ 62-PMB-050-6-12 (5 Amp Delta) L L L L CX CX CY CX L CY L CY 63-PMF-030-8-14 and 63-PMF-080-8-14 (3 and 8 Amp Wye) Applications ■ Circuit Diagram CX L Digital equipment Industrial equipment (UPS, inverters and converters) Automation equipment Computerized washing machines CY L CY CX L CX CY L CY 63-PMF-160-9-21 (16 Amp Wye) L L L CX CX CX CX CX CX L CY CY Specifications Model Rated Voltage (@ 50/60Hz) Rated Current Leakage Current (Max.) CY CX Inductance (L1) Temperature Rise (Max.) 62-PMB-050-6-12 250VAC 5A 0.6mA 2200pF 0.22uF 115mH 45°C 1.0mA 4700pF (4X) 470uF (3X) 3.0mA 0.015uF (2X) 1.0uF (6X) 3A 63-PMF-030-8-14 63-PMF-080-8-14 63-PMF-160-9-21 420VAC 8A 16A Capacitance 1.0mH (4X) 30°C 0.74mH (4X) 40°C 1.2mH (4X) 45°C Note: Test Voltage 1500VAC one minute, line to ground. Insulation Resistance: 300 MΩ min. at 500VDC. Voltage Drop: 1V max. at rated current. Weight: 8.82 ounces (250 grams) for 63-PMF-030-8-14 and 63-PMF-080-8-14 19.4 ounces (550 grams) for 62-PMB-050-6-12 51.5 ounces (1450 grams) for 63-PMF-160-9-21 88 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Temperature Characteristics Power Line Filters Three Phase Low Current/High Performance 62-PMB/63-PMF Series 62-PMB-050-6-12 (5 Amp) 5 — .157 (M4) .865 (22) 2.753 (70) 3.460 3.539 (88) (90) .865 (22) .039 (1) 1.376 (35) 63-PMF-030-8-14 and 63-PMF-080-8-14 (3 and 8 Amp) 4.444 (113) 4.050 (103) Fast-on tab #250 2 - .197 (ø5) Hole .629 (16) .708 (18) BL BK BL .547 (13.9) .547 (13.9) 3.585 (91.2) 1.809 (46) Dimensions in inches (mm) 4 - .216 (ø5.5) Hole Fast on tab #250 2.045 (52) .983 (25) 63-PMF-160-9-21 (16 Amp) BK .208 (5.3) .350 (8.9) .362 (9.2) 4.404 (112) .350 (8.9) .350 (8.9) 4.286 (109) Fast on tab #250 (Ground tab) 3.146 (80.0±0.5) 5.112 (130.0) 5.702 (145 ± 0.5) 6.292 (160) Common Mode Normal Mode 62-PMB-050-6-12 (5 Amp) 62-PMB-050-6-12 (5 Amp) 63-PMF (3, 8 and 16 Amp) 63-PMF (3, 8 and 16 Amp) * General tolerance ±..059 (1.5) 1.494 (38) 2.359 (60) .708 (18) Power Line Filters * General .944 (24) tolerance ±.020 (0.5) 63-PMF-160-9-21 63-PMF-160-9-21 63-PMF-080-8-14 63-PMF-030-8-14 63-PMB-050-8-12 63-PMF-030-8-14 63-PMF-080-8-14 63-PMB-050-8-12 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 89 Power Line Filters Three Phase 13-PWF/PWL/PWB Series Features ■ Excellent attenuation for high voltage impulse Effective for both balanced and unbalanced three-phase loads Metal case provides effective EMI shielding Epoxy molded for internal component reliability Suitable for both Wye and Delta connection Excellent filtering characteristics for both normal and common mode Operating temperature: -40°C to +85°C ■ Designed for 3-phase 4-line power supply systems ■ ■ ■ ■ ■ ■ Circuit Diagram Circuit 1 Applications ■ Power Line Filters ■ ■ ■ Digital equipment Industrial equipment (UPS, inverters and converters) Automation equipment Computerized washing machines A A' B B' C C' N G N' Circuit 2 A A' B B' C C' N G N' Specifications Model 13-PWF-005-12-H 13-PWL-005-12-C 13-PWF-010-12-H 13-PWL-010-12-C 13-PWB-010-12-D 13-PWB-015-12-D 13-PWB-020-12-D 13-PWB-025-12-D 13-PWB-030-12-D Rated Voltage (@ 50/60Hz) Rated Current Leakage Current (Max.) Circuit Diagram Figure 1 A B A B 5A 10A 1.5mA 440/250VAC 15A 20A 25A 30A Temperature Rise (Max.) 30°C 2 C Note: Test Voltage 1500VAC one minute, line to ground. Insulation Resistance: 300 MΩ min. at 500VDC. Voltage Drop: 1V max. at rated current. 90 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Figure B Power Line Filters Three Phase 13-PWF/PWL/PWB Series Figure A Figure C 2.0 (51) 3.9 (98.5) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 13-PWF-005;-010;-PWL-005;-010;-PWB-010 13-PWB-010-12-D 70 Insertion Loss (dB) 60 50 40 13-PWF-010-12-H 13-PWL-010-12-C 30 13-PWB-010-12-D 20 10 60 50 40 13-PWF-005-12-H 13-PWL-005-12-C 30 20 13-PWF-010-12-H 13-PWL-010-12-C 10 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 Frequency (MHz) 13-PWB-015;-020;-025:-030 5 10 20 50 10 20 50 13-PWB-015;-020;-025:-030 80 70 13-PWB-015-12-D 13-PWB-020-12-D 13-PWB-025-12-D 70 13-PWB-015-12-D 13-PWB-020-12-D 13-PWB-025-12-D 60 50 Insertion Loss (dB) Insertion Loss (dB) 2 Frequency (MHz) 80 40 30 13-PWB-030-12-D 20 10 0 0.1 50Ω Level Meter 50Ω 80 13-PWF-005-12-H 13-PWL-005-12-C 70 Insertion Loss (dB) 50Ω 13-PWF-005;-010;-PWL-005;-010;-PWB-010 80 0 0.1 Power Line Filters 5.3 (135) Dimensions in inches (mm) 60 50 40 13-PWB-030-12-D 30 20 10 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 91 Power Line Filters Three Phase 13-PDF/PDL/PDB Series Features ■ Excellent attenuation for high voltage impulse Effective for both balanced and unbalanced three-phase loads Metal case provides effective EMI shielding Epoxy molded for internal component reliability Compact and economical Excellent filtering characteristics for both normal and common mode Operating temperature: -40°C to +85°C ■ Designed for 3-phase, 3-Delta connection system ■ ■ ■ ■ ■ ■ Circuit Diagram Circuit 1 Applications ■ Power Line Filters ■ ■ ■ Digital equipment Industrial equipment (UPS, inverters and converters) Automation equipment Switching power supplies A A' B B' C C' G Circuit 2 A A' B B' C C' G Specifications Model 13-PDF-005-11-J 13-PDL-005-11-D 13-PDF-010-11-J 13-PDL-010-11-D 13-PDB-010-11-D 13-PDB-015-11-D 13-PDB-020-11-D 13-PDB-025-11-D 13-PDB-030-11-D Rated Voltage (@ 50/60Hz) Rated Current Leakage Current (Max.) Circuit Diagram Figure 1 A B A B 5A 10A 1.5mA 440/250VAC 15A 20A 25A 30A Temperature Rise (Max.) 30°C 2 C Note: Test Voltage 1500VAC one minute, line to ground. Insulation Resistance: 300 MΩ min. at 500VDC. Voltage Drop: 1V max. at rated current. 92 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Figure B Ø .177 (4.5) (2X) Power Line Filters Three Phase 2.00 (51) 13-PDF/PDL/PDB Series 2.52 (64) 1.06 (27) 2.95 (75) 3.35 (85) Figure A Figure C Ø .177 (4.5) (2X) .25 (6.3) M4 THREAD (10X) .117 (4.5) 2.52 2.91 3.35 (64) (74) (85) 3.31 3.74 4.13 (84) (95) (105) 1.42 (36) 2.00 (51) 2.00 (51) 3.88 (98.5) 1.51 (38.5) 3.15 (80) 5.31 (135) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 13-PDF-005;-010; PDL-005;-010 PDB-010 50Ω Level Meter 50Ω 80 13-PDF-005-11-J 13-PDL-005-11-D 70 13-PDB-010-11-D 70 60 Insertion Loss (dB) Insertion Loss (dB) 50Ω 13-PDF-005;-010; PDL-005;-010 PDB-010 80 50 40 13-PDB-010-11-D 30 13-PDF-010-11-J 13-PDL-010-11-D 20 10 60 50 13-PDF-010-11-J 13-PDL-010-11-D 40 30 13-PDF-005-11-J 13-PDL-005-11-D 20 10 0 0.1 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 Frequency (MHz) 13-PDB-015;-020;-025:-030 5 10 20 50 10 20 50 13-PDB-015;-020;-025:-030 80 70 70 13-PDB-015-11-D 13-PDB-020-11-D 13-PDB-025-11-D 13-PDB-030-11-D Insertion Loss (dB) 60 50 40 30 13-PDB-030-11-D 20 10 0 0.1 2 Frequency (MHz) 80 Insertion Loss (dB) Power Line Filters Dimensions in inches (mm) 60 50 40 13-PDB-015-11-D 13-PDB-020-11-D 13-PDB-025-11-D 30 20 10 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 93 Power Line Filters Three Phase High Performance 13-PWB Series Features ■ Excellent attenuation for high voltage impulse Metal case provides effective EMI shielding Epoxy molded for internal component reliability Excellent filtering characteristics for both normal and common mode Various current ratings available: from 5 to 150 Amps Operating temperature: -40°C to +85°C ■ Designed for 3-phase, 4-line power systems ■ ■ ■ ■ ■ Applications ■ ■ Power Line Filters ■ ■ Power supplies for data systems Industrial equipment (UPS, inverters and converters) Automation equipment Telecommunications systems and equipment Circuit Diagram Circuit 1 A A' B B' C C' N G N' Circuit 2 A A' B B' C C' N G N' Specifications Model 13-PWB-005-12-A 13-PWB-010-12-B 13-PWB-020-12-B 13-PWB-035-12-C 13-PWB-050-13-C 13-PWB-080-14-D 13-PWB-100-14-D 13-PWB-150-14-E Rated Voltage (@ 50/60Hz) Rated Current 440/250VAC 5A 10A 20A 35A 50A 80A 100A 150A Leakage Current (Max.) Circuit Diagram 4.5mA 1 30°C 9.0mA 20mA Temperature Rise (Max.) 2 Note: Test Voltage 1500VAC one minute, line to ground. Insulation Resistance: 300 MΩ min. at 500VDC. Voltage Drop: 1V max. at rated current. 94 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Power Line Filters Three Phase H High Performance I L P M E F D 13-PWB Series K B A C G N J Dimensions Dimensions in inches (mm) B C 13-PWB-005-12-A 7.2 (184) 6.3 (160) 7.9 (202) 13-PWB-010-12-B 13-PWB-020-12-B 13-PWB-035-12-C 9.6 (243) 8.7 (220) 10.3 (261) 13-PWB-080-14-D 13.9 (354) 12.6 (320) E 2.4 (60) 1.7 (44) 3.1 (81) 13-PWB-050-13-C 13-PWB-100-14-D D 3.9 (99) 15.1 (384) 13-PWB-150-14-E F G H I J 3.5 (86) .70 (18) 2.3 (58) 3.9 (100) 3.8 (96) 4.9 (125) 6.1 (155) 7.3 (185) M N P 3.5 (90) M6 – – – M4 2.9 (74) 1.9 (49) M6 2.2 (56) M8 .25 x .37 (6.4 x 9.4) 1.8 (45) M8 .25 x .37 (6.4 x 9.5) .25 x .38 (6.4 x 9.6) 2.3 (58) M4 1.2 (30) 3.4 (86) 2.4 (62) 7.5 (190) 8.7 (220) 1.4 (35) 3.9 (100) .25 x .38 (6.4 x 9.7) .25 x .38 (6.4 x 9.8) .25 x .39 (6.4 x 9.9) .25 x .36 (6.4 x 9.10) .25 x .36 (6.4 x 9.11) 2.4 (61) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 50Ω 50Ω Level Meter 50Ω 13-PWB-005;-010;-020;-035 13-PWB-005;-010;-020;-035 120 120 13-PWB-010-12-A 105 13-PWB-005-12-A 105 13-PWB-010-12-A 13-PWB-020-12-A 90 Insertion Loss (dB) Insertion Loss (dB) L 1.5 (38) M4 .98 (25) K Power Line Filters A Model 75 13-PWB-020-12-A 60 13-PWB-035-12-A 45 30 90 75 60 13-PWB-035-12-A 45 30 13-PWB-005-12-A 15 15 0 0.1 0 0.2 0.5 1 2 5 10 20 0.1 50 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) Frequency (MHz) 13-PWB-050;-080;-100;-150 13-PWB-050;-080;-100;-150 120 120 13-PWB-080-14-D 13-PWB-100-14-D 13-PWB-080-14-D 105 105 90 75 60 13-PWB-150-14-E 13-PWB-050-13-C 45 30 15 Insertion Loss (dB) Insertion Loss (dB) 13-PWB-100-14-D 90 75 13-PWB-050-13-C 60 45 13-PWB-150-14-E 30 15 0 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 95 Power Line Filters Three Phase High Performance 13-PDB Series Features ■ Excellent attenuation for high voltage impulse Metal case provides effective EMI shielding Epoxy molded for internal component reliability Excellent filtering characteristics for both normal and common mode Various current ratings available: from 5 to 200 Amps Operating temperature: -40°C to +85°C ■ Designed for 3-phase, 3-line connection systems ■ ■ ■ ■ ■ Applications ■ ■ Digital equipment Industrial equipment (UPS, inverters and converters) Circuit Diagram Circuit 1 A A' B B' C C' G Power Line Filters Circuit 2 A A' B B' C C' G Specifications Model 13-PDB-005-12-A 13-PDB-010-12-A 13-PDB-020-12-B 13-PDB-035-12-B 13-PDB-050-13-B 13-PDB-080-13-C 13-PDB-100-14-C 13-PDB-150-14-C 13-PDB-200-14-D Rated Voltage (@ 50/60Hz) Rated Current 440/250VAC 5A 10A 20A 35A 50A 80A 100A 150A 200A Leakage Current (Max.) Circuit Diagram Temperature Rise (Max.) 4.5mA 1 30°C 9.0mA 20mA 2 Note: Test Voltage 2250VDC one minute, line to ground. Insulation Resistance: 500MΩ. 96 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Power Line Filters Three Phase High Performance I L P H F D M E 13-PDB Series B A C G N J K Dimensions Model A B C D E F G H I J K M N Dimensions in inches (mm) P L 13-PDB-005-12-A 7.2 (184) 6.3 (160) 7.9 (202) 1.6 (42) 2.4 (60) 3.3 (86) .70 (18) 2.3 (58) M4 1.5 (38) – – – M4 9.6 (243) 8.7 (220) 10.3 (261) 2.3 (58) 2.7 (70) 3.9 (100) .98 (25) M6 2.3 (58) 1.9 (49) M6 13-PDB-020-12-B 13-PDB-035-12-B 13-PDB-050-13-B 13-PDB-100-14-C 13.9 (354) 13-PDB-150-14-C 12.6 (320) 15.1 (384) 6.1 (155) 2.5 (66) 13-PDB-200-14-D 7.3 (185) .25 x .37 (6.4 x 9.5) .25 x .38 (6.4 x 9.6) .25 x .38 (6.4 x 9.7) .25 x .38 (6.4 x 9.8) 3.5 (90) 13-PDB-080-13-C 2.9 (74) .25 x .37 (6.4 x 9.4) M4 1.2 (30) M8 3.3 (86) 2.4 (62) .25 x .39 (6.4 x 9.9) 2.2 (56) M8 Common Mode .25 x .36 (6.4 x 9.11) .25 x .36 (6.4 x 9.12) 2.4 (61) 7.5 (190) 8.6 (220) 1.4 (35) 3.9 (100) .25 x .36 (6.4 x 9.10) Power Line Filters 13-PDB-010-12-A Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 13-PDB-005;-010;-020;-035 50Ω 50Ω Level Meter 50Ω 13-PDB-005;-010;-020;-035 120 120 13-PDB-010-12-A 105 13-PDB-020-12-B 13-PDB-005-12-A 90 Insertion Loss (dB) Insertion Loss (dB) 105 75 60 13-PDB-035-12-B 45 13-PDB-005-12-A 30 15 0 0 0.02 .1 1 10 75 60 45 13-PDB-035-12-B 30 13-PDB-020-12-B 15 13-PDB-010-12-A 0.01 90 20 30 0 0 60 0.01 0.02 .1 Frequency (MHz) 13-PDB-050;-080;-100;-150;-200 10 30 60 120 105 105 90 13-PDB-080-13-C 75 60 45 13-PDB-150-14-C 30 Insertion Loss (dB) 13-PDB-100-14-C 13-PDB-050-13-B 13-PDB-100-14-C 13-PDB-050-13-B 90 13-PDB-200-14-D 75 60 45 13-PDB-080-13-C 30 13-PDB-150-14-C 13-PDB-200-14-D 15 0 0 20 13-PDB-050;-080;-100;-150;-200 120 Insertion Loss (dB) 1 Frequency (MHz) 15 0.01 0.02 .1 1 10 Frequency (MHz) 20 30 60 0 0 0.01 0.02 .1 1 10 20 30 60 Frequency (MHz) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 97 Military/Aerospace Multisection Filters Features ■ ■ ■ ■ ■ ■ ■ High common and differential mode attenuation Standard designs up to 100 Amps Excellent insertion loss characteristics up to 1 GHz Voltage rating 115-250VAC and 400VDC up to 400 Hz Available to meet MIL-F-15733 and MIL-STD-461 standards Available to meet TEMPEST and FCC requirements Custom designs available The High Performance Power Line Filters shown on pages 99 through 105 are designed to meet the following criteria. The information shown can be used as a basis for filter specifications. (Contact factory for additional details). Applications ■ ■ Military/Aerospace Multisection Filters ■ ■ ■ Military Commercial & military/aerospace Secured communications Switching power supplies Data processing equipment ■ ■ ■ ■ ■ Ruggedized computers Radar Electronic warfare Ground/air weapon systems Satellites Test Specifications Test Group Order of Test Examination or Test Test Method (Per MIL-STD-202) Post Test Requirements 1 Voltage Drop Paragraph 4.6.8 of MIL-F-15733 Three percent of rated voltage max. 2 Leakage Current UL 1283 Per applicable specification 3 Temperature Rise MIL-F-15733 Paragraph 4.6.4 25°C max. 4 Terminal Strength Method 211, Condition A No evidence of loosening or rupture. 5 lb. applied force. Line Cords: 35 Lbs. 1 Shock, Medium Impact Method 213, Condition G Must pass DWV and Insertion Loss 2 Vibration, High Frequency Method 204, Condition A Monitor for shorts or open 3 Thermal Shock Method 107, Test Condition A Pass 90% DWV IR to be 30% of initial 4 Humidity Method 107, Condition B, except temperature equals 25°C Pass 90% DWV IR to be 30% of initial 1 Life Method 108, Condition D 1.2 x Rated AC voltage at max. operating temp. or 1.4 x DC voltage Pass 90% DWV insulation resistance to be 30% of initial. IIA IIB III 98 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Military/Aerospace Multisection Filters Insertion Loss 52-600-001 Insertion Loss (dB) 80 differential mode 60 Circuit Schematic 40 common mode 20 0 0.01 0.1 1 10 Frequency (MHz) 100 1000 100 1000 LINE LOAD 52-600-002 60 common mode 40 differential mode 20 0 0.01 0.1 1 10 Frequency (MHz) Military/Aerospace Multisection Filters Insertion Loss (dB) 80 Dimensions 1.250 (31.75) .250 Fast-on tabs (3 PL.) .240 (6.10) SWITCH 52-600-001 52-600-002 .215 (5.46) FUSE CONNECTOR .250 (6.35) 2.500 (63.50) .625 (15.8) 1.68 (42.67) 2.98 (75.70) Dimensions in inches (mm) Model Temperature Rating DCR. max. (ohms) Leakage Current (max.) Mode (max.) 52-600-001 5A 120/240VAC -40°C to +65°C .20 1 mA 60 Hz 120/240VAC 60 Hz 2.120 ± .010 (53.85) 3.88 (98.55) Voltage Rating 10A .03 R. 4 PL 2.500 (63.50) CHASSIS MOUNTING HOLE #6-32 THREADED INSERTS (4 PL.) (3.50-32) Current Rating 52-600-002 1.250 (31.75) -40°C to +65°C .10 1 mA Minimum Insertion Loss (db) Per MIL-STD-220 50K 150K 300K 1M 10M 100M 1G COMM 33 65 80 80 80 80 60 DIFF 37 65 80 80 80 – – COMM – 50 70 80 80 70 60 DIFF 25 50 75 80 80 – – Consult factory for UL/CSA approval availability. SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 99 HIGH PERFORMANCE Military/Aerospace Power Line Filters for C.O.T.S./ Multisection Filters TEMPEST Applications # 52-600-001 52-600-002 Circuit Schematic Insertion Loss 52-523-002 52-523-002 LINE Insertion Loss (dB) 80 LOAD 60 40 20 0 0.01 0.1 1 10 Frequency (MHz) 100 1000 Dimensions Military/Aerospace Multisection Filters 52-523-002 .750 (19.05) .600 (15.24) 2.010 (51.05) .250 (6.35) .250 (6.35) 3.000 (76.2) .375 (9.52) FUSEHOLDER 1.75 .875 (44.4) (22.2) 3.50 .875 (88.9) (22.2) PLUG #6-32 THDED INSERT 4 PLCS. (3.50-32) 4.00 (101.6) .625 (15.8) 1.25 (31.75) Dimensions in inches (mm) Model Current Rating Voltage Rating Temperature Rating DCR max. (ohms) Leakage Current (max.) Mode (max.) 52-523-002 5A 120/240VAC -40°C to +65°C .25 1 mA COMM – 55 60 80 80 70 60 DIFF – 50 60 80 80 – – 60 Hz Minimum Insertion Loss (db) Per MIL-STD-220 50K 150K 300K 1M 10M 100M 1G Consult factory for UL/CSA approval availability. 100 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Military/Aerospace Multisection Filters Insertion Loss 1212-0502 Insertion Loss (dB) 80 Circuit Schematic 60 1212-0502 40 20 0 0.01 0.1 1 10 Frequency (MHz) 100 1000 Dimensions .219 TYP. (5.56) .656 (16.41) .418 (10.62) 1.000 (25.4) .500 (12.7) .209 (5.31) .120 TYP. (3.05) .594 ± .031 ± (.78) 1.187 ± .015 (30.15 ± .38) 1.125 (28.58) MOUNTING SURFACE .032 (.81) .125 6-PLCS. (3.18 ± .00) .875 (22.23) 1.250 (31.75) .105 TYP. (2.67) .281 ± .031 (7.14 ± .78) .710 (18.03) .187 (4.75) 1.437 ± .031 (36.50 ± .78) Dimensions in inches (mm) Model Current Rating 1212-0502 10A Voltage Rating 350VDC Temperature Rating -55°C to +125°C DCR max. (ohms) Leakage Current (max.) Cx Value .01 1 mA 5000pF Military/Aerospace Multisection Filters .055 TYP. (1.40) 1212-0502 Minimum Insertion Loss (db) Per MIL-STD-220 10M 100M 500M 1G 20 65 70 70 240VAC 60 Hz Consult factory for UL/CSA approval availability. SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 101 Military/Aerospace Multisection Filters Secure Communications Spectrum's electromagnetic compatibility expertise in the secure communication or “TEMPEST” arena is represented by this group of high performance filters. These units are especially well suited for use in MIL-STD-461 applications to reduce conducted emissions. The filters are manufactured with glass sealed terminals and connectors. Filter Schematic A LINE Features ■ ■ ■ ■ A A C C B B Filter Schematic B LINE LOAD A A C C B B Dimensions 2.50 (63.50) 1.25 (31.75) Insertion Loss 1.75 (44.45) 52-378-002, -004 MIL-STD-220 80 52-378-002 Insertion Loss (dB) Military/Aerospace Multisection Filters ■ Excellent insertion loss profile Available for DC & AC applications up to 400 Hz Available for 3-14 Amp applications Custom systems can be designed to your specific needs QPL to MIL-F 15733/63-0001 LOAD 1.500 (38.10) .750 2.50 (19.05) (63.50) #8-32 UNC THD. INSERTS (4.17-32) .350 DEEP, 2 PLACES (8.89) CONNECTOR #8001-14S-7P-A3 MATES WITH MS-3106-14S-7S 60 40 20 0 0.01 0.1 1 10 Frequency (MHz) 100 1000 Dimensions in inches (mm) 102 Minimum Insertion Loss (db) Model Current Rating Voltage Rating Temperature Range DCR max. (ohms) Leakage Current (max.) Schematic 52-378-001 3 Amps 240VAC 60 Hz Line to Line -55°C to 85°C .3 50 mA A 30 60 70 80 80 70 70 52-378-002 5 Amps 240VAC 60 Hz Line to Line -55°C to 85°C .2 50 mA B 24 64 70 80 80 70 70 52-378-004 5 Amps 240VAC 60 Hz Line to Line -55°C to 85°C .2 50 mA A 34 64 70 80 80 70 70 52-378-005 3 Amps 240VAC 60 Hz Line to Line -55°C to 85°C .3 50 mA B 40 70 80 80 80 70 60 50 150 300 1 10 100 1 KHz KHz KHz MHz MHZ MHZ GHz SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Power Line Filters Military/Aerospace Multisection Filters for Secure Communications Filter Schematic C Insertion Loss LINE 52-387-010, -003 MIL-STD-220 52-409-001 MIL-STD-220 LOAD A A C C B B 60 52-387-010, -003 MIL-STD-220 40 Filter Schematic D 52-409-001 MIL-STD-220 20 0 0.01 0.1 1 10 Frequency (MHz) LINE 100 LOAD A A C C B B 1000 Military/Aerospace Multisection Filters Insertion Loss (dB) 80 Filter Schematic E LINE 3 Phase and 400 Hz models available. Please consult the factory. LOAD A A C C B B Dimensions Figure 1 2.50 (63.50) 1.25 (31.75) Figure 2 3.00 (76.20) 2.50 (63.50) 1.25 (31.75) .625 (15.87) #8-32 UNC (4.17-32) STUD 1.25 (31.75) 1.500 (38.10) .750 2.50 (19.05) (63.50) 1.500 (38.10) .750 2.50 (19.05) (63.50) #8-32 UNC THD. INSERTS (4.17-32) .350 DEEP, 2 PLACES (8.89) Current Rating CONNECTOR #8001-10SL-3PN-FP-A3 MATES WITH MS-3106-10SL-3S Voltage Rating Model Fig. 52-387-010 1 10 Amps 240VAC 60 Hz Line to Line 52-387-012 1 5 Amps 52-409-001 2 #8-32 UNC THD. INSERTS (4.17-32) .350 DEEP, 2 PLACES (8.89) Dimensions in inches (mm) Temperature Range DCR Leakage max. Current (ohms) (max.) common 24 60 70 80 80 70 70 common 34 64 70 80 80 70 70 differential 30 30 70 80 80 – – common 14 30 45 80 80 70 60 C 240VAC 400 Hz -55°C to 85°C Line to Line .2 5 mA D 50 mA 50 150 300 1.0 10 100 1 KHz KHz KHz MHz MHz MHz GHz Mode 50 mA .04 Dimensions in inches (mm) Sch. .2 -55°C to 85°C CONNECTOR #8001-14S-7P-A3 MATES WITH MS-3106-14S-7S Minimum Insertion Loss (db) -55°C to 85°C 14 Amps 240VAC 60 Hz Line to Line 1.75 (44.45) E SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 103 Military/Aerospace Multisection Filters Secure Communications Features ■ ■ ■ ■ ■ ■ ■ Meets applicable sections of MIL-F-15733 Excellent performance Integral IEC connector Available with integral fused IEC connector and two pole switch Current ratings to 15 Amps Custom designs available Designed to meet TEMPEST requirements Part Numbering System: 760 - A 06 Q Model Military/Aerospace Multisection Filters Current Rating: 3, 6, 10, 15 Amps Electrical Specifications Rated current ranges .................. Rated voltage............................. Operating frequency................... Maximum leakage current @115VAC 60 Hz............ @250VAC 50 Hz............ Test voltage Line-to-Line .................... Line-to-Ground............... 3, 6, 10, 15 Amps 115-250VAC 50-60 Hz Terminal Style: A=.25 Quick Connect C=Wire Leads (4" min.) 1.2 mA 2.5 mA Series: 760; 761 or 762 1450VDC 2250VDC Insertion Loss 760, 761, 762 - 3, 6 Amps 760, 761, 762 - 10, 15 Amps common mode 80 Insertion Loss (dB) Insertion Loss (dB) 80 60 40 20 differential mode 0 0.01 0.1 1 10 Frequency (MHz) 100 1000 common mode 60 40 20 differential mode 0 0.01 0.1 1 10 Frequency (MHz) 100 1000 Common Mode (CM) is tested in a 50 ohm system with all lines tied together on the line and load sides of the filter. Differential Mode (DM) is tested in a 50 ohm system using a 180˚ phase splitter on both sides of the filter. 104 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Military/Aerospace Multisection Filters Dimensions - 760 Series .55 (13.97) Current Rating (Amps) Series B C 3, 6 2.25 (57.15) 3.00 (76.20) 1.88 (47.75) 10, 15 5.50 (139.70) 3.15 (88.01) 2.10 (53.34) A 760 1.23 (31.24) Filter Dimensions A .13 (3.30) B 1.332 (33.83) .67 (42.41) C .66 (16.67) TERMINATION STYLE “A” 8-32 Inserts (4 Places) TERMINATION STYLE “C” Dimensions in inches (mm) Dimensions - 761, 762 Series C Series Current Rating (Amps) 761, 762 Filter Dimensions A B C 3, 6 2.55 (64.77) 2.97 (75.43) 1.88 (47.75) 761 10, 15 5.50 (139.70) 3.15 (88.01) 2.10 (53.34) 762 10, 15 5.75 (146.05) 3.15 (88.01) 2.10 (53.34) Military/Aerospace Multisection Filters 1.312 (33.32) .95 (24.13) 3.00 (76.2) 0.20 (5.08) 1.30 (33.02) 1.30 (33.02) 0.20 (5.08) A 0.80 (20.32) 1.875 (47.62) 6-32 UNC-2B (6 Places) B 3.67 (93.21) 0.80 (20.32) .40 (10.16) Switch Omitted in Model 761 3, 6, 10, AMP FRONT PANEL Switch Omitted in Model 761 15 AMP FRONT PANEL .55 (13.97) Dimensions in inches (mm) SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 105 Custom/Application Specific Filters SpectrumControl will address virtually any requirement for a custom power product. Our many years of experience in providing EMI/RFI solutions has allowed us to satisfy both global EMC regulations and time-to-market constraints. Spectrum Control’s engineering expertise and vertical integration reduces your speed-to-market, as well as saves you money. Features/Benefits ■ ■ ■ ■ ■ ■ ■ ■ ■ Custom/Application Specific Filters ■ Incorporates filtering and custom circuitry into one design package SCI’s EMC Test Facility will define compliance issues Current and voltage ratings to meet your specifications Specific circuit designs to accommodate your application Reduces your development time Increases speed-to-market Designed to perform in industrial environments Designs incorporate filtering for both common and differential modes Ensures reliability (all parts are 100% tested) Designed to meet agency approvals Options ■ ■ ■ ■ ■ EMI filtering Transient protection Circuit breaker protection Voltage cut-off Reverse polarity ■ ■ ■ ■ Power distribution Indicator lights Leads or studs Agency approvals Performance Characteristics Insertion loss range Effective filtering from 10 KHz to 10 MHz with proper installation Current ratings (max.) up to 500 Amps Voltage ratings (max.) 400VDC and 240VAC standard, custom ratings available Leakage current ratings Varies, low leakage designs available Temperature -25° C to +85° C Specify your required current rating, voltage ratings and capacitance value. 106 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 EMI Filtering Custom/Application Specific Filters Circuit Breaker Protection Power Distribution Multiple Outlets Power Distribution Power Entry EMI Filtering Transient Protection -48 VDC -60 VDC Rugged Construction Pigtail Leads Low Voltage Cut-off UL Recognized Complies to UL 1459 CSA Certified Custom/Application Specific Filters Three-Phase Delta EMI Filter High Current Terminal Block Custom Ground Plate SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 107 Custom/Application Specific Filters Spectrum Control's design teams can help transform a functional electronic design into an easy to install EMI filtered package containing all required components. We will define your EMC problem through our test facilities, develop a filter solution and manufacture product to meet your schedule. By designing and manufacturing your entire assembly, Spectrum Control will: ■ ■ ■ ■ ■ Custom/Application Specific Filters ■ Reduce development time Combine your design into a compact, filtered package Simplify installation, saving time and money Increase productivity Complement your inventory control program Reduce your vendor base 108 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Custom/Application Specific Filters Single Line Filters Power Distribution Units Filtered Terminal Blocks PSM High Current Surface Mount Filters Custom/Application Specific Filters Power Line Filters Remote control options available with intelligent power distribution units. SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 109 Appendix Part Number Index 110 Spectrum part # . . . . . . . . . . .Page Spectrum part # . . . . . . . . . . .Page Spectrum part # . . . . . . . . . . .Page 10-BPF-XXX-2-X . . . . . . . . . . . . . .32 10-BPF-XXX-5-X . . . . . . . . . . . . . .30 10-BPL-XXX-5-X . . . . . . . . . . . . . .38 11-MPC-XXX-X-X . . . . . . . . . . . . .58 12-MMB-XXX-5-X . . . . . . . . . . . . .82 12-MMB-XXX-5-X . . . . . . . . . . . . .86 12-MMB-XXX-11-X . . . . . . . . . . . .84 12-MMF-XXX-5-X . . . . . . . . . . . . .82 12-MMF-XXX-5-X . . . . . . . . . . . . .86 12-MMF-XXX-11-X . . . . . . . . . . . .84 12-PMB-XXX-DC-X . . . . . . . . . . . .78 12-PMB-XXX-X-X . . . . . . . . . . . . .76 12-PMF-XXX-DC-X . . . . . . . . . . . .78 12-PMF-XXX-2-X . . . . . . . . . . . . .66 12-PMF-XXX-5-X . . . . . . . . . . . . .72 12-PML-XXX-X-X . . . . . . . . . . . . .66 13-PDB-XXX-XX-X . . . . . . . . . . . .92 13-PDB-XXX-XX-X . . . . . . . . . . . .96 13-PDF-XXX-XX-X . . . . . . . . . . . .92 13-PDL-XXX-XX-X . . . . . . . . . . . .92 13-PWB-XXX-XX-A . . . . . . . . . . . .94 13-PWB-XXX-XX-B . . . . . . . . . . . .94 13-PWB-XXX-XX-C . . . . . . . . . . . .94 13-PWB-XXX-14-D . . . . . . . . . . . .94 13-PWB-XXX-XX-E . . . . . . . . . . . .94 13-PWB-010-12-D . . . . . . . . . . . . .90 13-PWB-015-12-D . . . . . . . . . . . . .90 13-PWB-020-12-D . . . . . . . . . . . . .90 13-PWB-025-12-D . . . . . . . . . . . . .90 13-PWB-030-12-D . . . . . . . . . . . . .90 13-PWF-XXX-XX-X . . . . . . . . . . . .90 13-PWL-XXX-XX-X . . . . . . . . . . . .90 52-226-001 . . . . . . . . . . . . . . . . . .20 52-226-002 . . . . . . . . . . . . . . . . . .20 52-226-004 . . . . . . . . . . . . . . . . . .20 52-226-006 . . . . . . . . . . . . . . . . . .20 52-226-008 . . . . . . . . . . . . . . . . . .20 52-226-009 . . . . . . . . . . . . . . . . . .20 52-226-011-XX . . . . . . . . . . . . . . .12 52-226-015 . . . . . . . . . . . . . . . . . .20 52-226-016-XX . . . . . . . . . . . . . . .16 52-226-019-XX . . . . . . . . . . . . . . .18 52-226-020-XX . . . . . . . . . . . . . . .14 52-226-021-XX . . . . . . . . . . . . . . .12 52-226-026-XX . . . . . . . . . . . . . . .16 52-226-029-XX . . . . . . . . . . . . . . .14 52-226-031-XX . . . . . . . . . . . . . . .12 52-226-036-XX . . . . . . . . . . . . . . .16 52-226-037-XX . . . . . . . . . . . . . . .18 52-226-041-XX . . . . . . . . . . . . . . .12 52-226-046-XX . . . . . . . . . . . . . . .16 52-267-002 . . . . . . . . . . . . . . . . . .20 52-267-003 . . . . . . . . . . . . . . . . . .20 52-267-008 . . . . . . . . . . . . . . . . . .20 52-267-009 . . . . . . . . . . . . . . . . . .20 52-267-010 . . . . . . . . . . . . . . . . . .20 52-267-011 . . . . . . . . . . . . . . . . . .20 52-267-012 . . . . . . . . . . . . . . . . . .20 52-378-XXX . . . . . . . . . . . . . . . .102 52-387-XXX . . . . . . . . . . . . . . . .103 52-409-XXX . . . . . . . . . . . . . . . .103 52-523-002 . . . . . . . . . . . . . . . . .100 52-600-XXX . . . . . . . . . . . . . . . . .99 52-1013-XXX . . . . . . . . . . . . . . . .23 60-BHP-XXX-X-X . . . . . . . . . . . . .56 60-BHS-XXX-X-X . . . . . . . . . . . . .28 60-BPF-XXX-X-X . . . . . . . . . . . . .26 60-BPL-XXX-X-X . . . . . . . . . . . . . .36 60-BPP-XXX-X-X . . . . . . . . . . . . .54 60-BPR-XXX-X-X . . . . . . . . . . . . .24 60-BPS-XXX-X-X . . . . . . . . . . . . .24 60-SPL-XXX-X-X . . . . . . . . . . . . . .34 60-SPR-XXX-X-X . . . . . . . . . . . . .40 60-SPS-XXX-X-X . . . . . . . . . . . . .40 61-MPC-XXX-X-XX . . . . . . . . . . . .52 62-AFC-XXX-X-XX . . . . . . . . . . . .60 62-AFL-XXX-X-XX . . . . . . . . . . . . .60 62-LMF-XXX-X-XX . . . . . . . . . . . .68 62-LMB-XXX-X-XX . . . . . . . . . . . .68 62-MMF-XXX-X-XX . . . . . . . . . . . .80 62-PMB-XXX-5-XX . . . . . . . . . . . .70 62-PMB-XXX-6-XX . . . . . . . . . . . .88 62-PMB-XXX-X-XX . . . . . . . . . . . .74 62-PMF-XXX-5-XX . . . . . . . . . . . .70 62-PML-XXX-X-XX . . . . . . . . . . . .64 62-PPF-XXX-X-XX . . . . . . . . . . . .62 62-PQF-XXX-X-XX . . . . . . . . . . . .62 62-PRF-XXX-X-XX . . . . . . . . . . . .62 63-PMF-XXX-8-XX . . . . . . . . . . . .88 63-PMF-XXX-9-XX . . . . . . . . . . . .88 64-BFF-XXX-X-X . . . . . . . . . . . . . .42 64-BFS-XXX-X-X . . . . . . . . . . . . .42 64-BSF-XXX-X-XX . . . . . . . . . . . .46 64-SSF-XXX-X-XX . . . . . . . . . . . .46 65-BFF-XXX-X-X . . . . . . . . . . . . . .42 65-BFS-XXX-X-X . . . . . . . . . . . . .42 65-BSF-XXX-X-XX . . . . . . . . . . . .46 65-SSF-XXX-X-XX . . . . . . . . . . . .46 66-BFF-XXX-X-X . . . . . . . . . . . . . .44 66-BFS-XXX-X-X . . . . . . . . . . . . .44 66-BFS-XXX-X-X . . . . . . . . . . . . .44 66-BSF-XXX-X-XX . . . . . . . . . . . .48 66-SSF-XXX-X-XX . . . . . . . . . . . .48 67-BFF-XXX-X-X . . . . . . . . . . . . . .44 67-BFS-XXX-XX . . . . . . . . . . . . . .44 67-BSF-XXX-X-X . . . . . . . . . . . . .48 67-SSF-XXX-X-X . . . . . . . . . . . . .48 68-BSF-XXX-X-XX . . . . . . . . . . . .50 760-XXXX . . . . . . . . . . . . . . . . . .106 761-XXXX . . . . . . . . . . . . . . . . . .106 762-XXXX . . . . . . . . . . . . . . . . . .106 1212-0502 . . . . . . . . . . . . . . . . . .101 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Appendix Notes SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 111 Appendix Notes 112 SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Design Inquiry Form Request for Quote/Custom Design Form Outlet/Inlet Type: Duplex Single IEC Vendor P/N Company name Other Name/Title AC Requirements: Address City Phone ( State ) Fax ( 120VAC Other Zip ) Frequency (Hz): Target price Anticipated yearly usage Current (Amps): Life of program 250VAC 50 400 60 Other Current/ phase (Amps): Phase requirements: Single Customer Time Line (fill in dates): Three Quotation Delta (3 wires) Prototype Wye (4 wires) First Article Other Production Start Up Leakage Current: Product Offering Suggested for this Application: (Check appropriate response) DC Requirements: Custom Assembly (Multi-Section Filter) mA (max.) Voltage: Current (Amps): Custom Assembly (Power Distribution Unit) Insertion Loss Requirements: Power Entry Filter Common mode (load) (no load) Differential mode (no load) High Current Single/Dual Line Filter Accessories Physical Parameters Mechanical Requirements: Surge Suppression: Maximum Dimensions: Height (inches) Length (inches) No Yes Define Width Please include drawing or sketch, if available. Circuit Breaker: Electrical Parameters No Current Rating LOAD SIDE Vendor P/N Lighted Non-lighted Remote None UL CE CSA TUV Connector Studs Switches: Pigtails/leads Connector Terminal Block Agency Approvals: Appendix Voltage Rating Electrical Terminations: LINE SIDE Yes Other Other SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 113 A Control Products Systems Company & As A Control Products & Systems Company, we strive to meet our customers’ needs by providing greater component and system solutions to their design problems. Our family of interference, power and microwave products is now the broadest line in the industry. These engineering driven products deliver unmatched performance in the high frequencies common to new applications. To satisfy the increased demand that corresponds with our growth, we’ve conducted a major manufacturing expansion. This additional manufacturing capacity involves all of our facilities and is highlighted by our new plants in Juarez, Mexico and Guang Dong, China. These expanded facilities produce components and systems for all of our groups and have received numerous positive customer audits. Global Manufacturing Signal & Power Integrity Group As a vertically integrated producer of ceramic capacitors and filters, we continue to provide the widest range of discrete EMI filters, filtered connectors, ferrite inductors and filtered power products. In addition, we have extended our ceramic technology to develop our line of wireless components. ■ Low Pass EMI Filters ■ Ceramic Capacitors ■ Filtered Terminal Blocks ■ Single Line Filters and Filter Plates ■ Filtered Terminal Blocks ■ Filtered Connectors ■ Power Entry Modules ■ Datacom Connectors and Power Line Filters ■ Ferrite Inductors ■ Multisection Filters EMI Filters and Filtered Power Products Frequency Control Group In order to expand our line of microwave products, we recently acquired FSY Microwave, including all products and design expertise. The new Spectrum FSY Microwave family of SPECWAVE components and systems provides a wide range of frequency control solutions. ■ Bandpass Filters ■ Suspended Substrates and Duplexers ■ Cavity Filters ■ Patch Antenna ■ Coaxial Tubular Filters Elements ■ Microwave Custom ■ Waveguide Filters Assemblies ■ Lumped Element Filters Frequency Control Products Power Management Systems Group Several years ago, we began to apply our fundamental filtering expertise to improve power management. The result is a complete line of standard, yet customizable power distribution units and remote management systems. ■ SMARTstart AC/DC Intelligent Power Distribution Units ■ SHARPstart AC/DC Power Distribution Units ■ Custom Commercial Assemblies 114 Power Management Systems CERTIFIED SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 Our new Check Stock system allows you to gather instant information regarding a particular component’s inventory status at Spectrum Control’s network of authorized distributors. Selecting the Check Stock icon will provide you with distributor names, part numbers, quantity on hand, online ordering capability and the last date the inventory was updated for that particular component. Use Check Stock to improve your organization’s efficiency by simplifying inventory management and reducing inventory We’ve made finding the right product for your application easier than ever. By using our new online catalog you can tell us the performance parameters you need and we’ll help you locate the appropriate product. You start by identifying your mechanical package, add some required electrical characteristics and we’ll show you applicable standard part numbers and how they compare to your specifications. New Design Direct allows you to work with our engineers in a collaborative online effort to develop a custom solution tailored to your specific needs. After registering on our site, you’ll be able to create and track your project, entirely online. As our engineering team makes changes to your project, you’ll receive an e-mail with a direct link to see the current status and provide feedback. Designing a custom solution has never been easier. To see all of our new online tools, come visit us @ www.spectrumcontrol.com SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 115 A Control Products Systems Company & Signal & Power Integrity Products Ferrite beads & inductors Surface mount filters Discrete EMI filters Filter plates Filter connectors Gaskets & shielding Ceramic capacitors Single line filters Filtered terminal blocks Power entry & power line filters Military/multisection filters EMC testing www.spectrumcontrol.com Corporate Headquarters 8031 Avonia Road Fairview, Pennsylvania 16415 Phone: 814-474-2207 Fax: 814-474-2208 NEW Signal & Power Integrity 8061 Avonia Road Fairview, Pennsylvania 16415 Phone: 814-474-1571 Fax: 814-474-3110 Sales Offices NORTH AMERICA NEW 6798 Oak Hall Lane Columbia, Maryland 21045 Phone: 301-916-2919 Fax: 301-916-2910 EUROPE Spectrum Control GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58 Frequency Control Products Resonators Bandpass filters & duplexers Patch antenna elements Waveguide filters Combiners Couplers Duplexer-LNA assemblies Lumped element filters Suspended Substrates Cavity filters Coaxial tubular filters Microwave custom assemblies Tower mount amplifiers www.specwave.com Represented or Distributed by: Power Management Systems AC/DC power distribution units & remote reboot power management systems Custom assemblies Power strips www.specpower.com AHA 12/03 20M 27-0027-0046 CHINA Spectrum Control Limited Room 73-78 - 2nd Floor Sino Industrial Plaza NEW 9 Kai Cheung Road Kowloon Bay Kowloon, Hong Kong Phone: (011)-852-2197-9912 Fax: (011)-852-2750-9663 For additional information regarding Spectrum Control, our full line of EMI filtering and power products and our many new products, call us or contact our Website at http://www.spectrumcontrol.com Spectrum Control, Inc. reserves the right to alter the specifications provided in this publication. Consult factory for current specifications. CERTIFIED © Spectrum Control, Inc. Printed in U.S.A. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: API Technologies: 1212-0502