EMI Power Filters Catalog

advertisement
EMI Power Filters
CERTIFIED
Signal & Power Integrity Group
EMI Power
Filters
Spectrum Control EMI filtered power products prevent
unwanted interference from entering your system, as
well as eliminate emissions that can contaminate the
AC power grid. Our standard and custom products
are available in a wide range of AC/DC current and
voltage ratings to address EMI filtering for high current
applications. All Spectrum power products are
designed to meet global EMC emissions regulations.
Spectrum Control is committed to providing an
integrated approach to EMC problem solving by offering
customers consulting, diagnostic testing, design and
manufacturing services. As a fully integrated manufacturer,
Spectrum Control is able to respond to short lead time
requests for new prototypes and variations to standard
products. This enables us to provide the most costeffective solution that satisfies both your performance
and budgetary needs.
In addition, our family of power products provide
low cost solutions to EMI challenges, helping you
lower inventories and increase production assembly
efficiency.
Spectrum Control power products are used in
a variety of industries worldwide, including telecommunications, computers and peripherals, medical,
aerospace, military, power supplies, appliances
and industrial controls.
CERTIFIED
2
Signal & Power Integrity Group
A
Control Products
Systems Company
&
Spectrum Control Inc...
Page
• DC Single Line Feed-thru Series • AC Single Line Feed-thru Series
• DC Single Line Pi Series
• AC Single Line Pi Series
12 - 22
• Single Line Feed-thru Filters
Single Line Filters
High Current Filtered
Terminal Blocks
Power Entry Modules
• Fused Filtered
Power Entry Modules
• Switched & Fused Filtered
Power Entry Modules
• Switched & Fused Filtered
Power Entry Modules For
European Market
24 - 51
• Miniature Printed
Circuit Boards
• Power Entry Modules Bolt-in
Right Angle Terminals
• Power Entry Modules
High Frequency
Attenuation Bolt-in
• PCB Power Filters Miniature
Printed Circuit Boards
52 - 59
• Appliance Filters
• Single Stage
• Single Stage Wire Leads
• Single Stage Wire Leads for
Medical Purpose Applications
• Single Stage - Higher Current • Three Phase - Low
Current/High Performance
• DC - Higher Current
• Three Phase
• DC - Single Stage
• Dual Stage
• Three Phase - High Performance
Bolt-in Rear Terminals
Bolt-in Right Angle Terminals
High Frequency Attenuation
Snap-in With Wire Leads
Bolt-in With Wire Leads
Snap-in Mount
PCB Power Filters
Power Line Filters
Military/Aerospace
Multisection Filters
Custom/Application
Specific Filters
Appendix
23
• High Current Filtered
Terminal Blocks
60 - 97
• Military/Aerospace
Multisection Filters
98 - 105
• Custom/Application
Specific Filters
106 - 109
• Part Number Index
• Design Inquiry Form
• www.spectrumcontrol.com
Online tools
110 - 115
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
3
EMI Power Filters Selection Guide
Applications
High Current
Terminal Blocks
Cellular base stations, telephone
racks, high current switch mode
power supplies, power amplifiers
and servers
Cellular base stations, telecommunication switching networks,
hi-reliability radar & transmission
systems, industrial controls,
power supplies, UPS, instrumentation and power distribution
Digital equipment, personal
computers and peripherals,
measuring instruments,
home appliances, monitor
and display units
Digital equipment, personal
computers and peripherals,
measuring instruments, home
appliances, monitor and
display units
■ Easy installation Bolt-in style, surface mount
■ Rugged construction Provides protection to filtering element; especially
useful for repeated in-field
wiring changes
■ Rugged construction Designed to perform in
industrial environments
■ Design flexibility Available in PCB mount,
fast-on tab, solder lug or
flying leads
■ Performance Ideally suited for products
that must conform to FCC
part 15 regulations
Meets over-voltage of IEC
664 category II and
complies with IEC 950
Metal case provides maximum isolation that optimizes
performance
■ Agency approvals UL recognized, CSA certified,
TÜV approved (tested and
found to be in accordance
with VDE 0565 Part 3)
■ Custom options Value added connectors,
wire leads, ring terminals
■ Rugged construction Designed to perform in
industrial environments
■ Current ratings (max.) Up to 15 Amps
■ Voltage ratings (max.) From DC to 250 VAC,
60 Hz
■ Insertion loss range Effective filtering from
100 KHz to 30 MHz
■ Temperature range -25°C to +85°C
■ Leakage current range 0.35 mA to 0.50 mA max
■ Current ratings (max) 2, 4 and 6 Amps
■ Voltage ratings (max.) 125 VAC and 250 VAC
■ Insertion loss range Effective filtering from
100 KHz to 30 MHz
■ Temperature range -25°C to +85°C
■ Leakage current range 0.35 mA to 0.50 mA max
for general purpose filters
0.005 mA to 0.10 mA max
for medical filters
Pages 42-51
■ Design flexibility Available with single, dual,
triple and quad configurations, different stud lengths,
mounting brackets hardware
and EMI gasketing available.
■ Performance Ideally suited to help meet
NEBS, GR1089, and
EN55022
Features/
Benefits
■ Agency approvals Designed to meet agency
approvals, some selected
filters UL 1950 recognized,
CSA C22.2 certified and
TÜV approved
■ Custom options Custom interfacing, contact
pins, wire leads, multiple
outputs
■ Design flexibility 2 x 2 to 2 x 6 position
blocks
Terminal Blocks available
with either metric or US
threaded studs
■ Performance Filter elements provide
high insertion loss for EMI
filtering of DC power lines
to help meet NEBS,
GR1089, and EN55022
■ Agency approvals UL recognized
■ Environmental Can be used in both indoor
and outdoor applications
Performance
Characteristics
For data sheets on the
product you’re looking for,
enter the dedicated URL
4
■ Current ratings (max) To 500 Amps
■ Voltage ratings (max) To 1000 VDC
and to 240 VAC
■ Insertion loss range AC: 1 MHz to 1 GHz
DC: 150 KHz to 10 GHz
■ Temperature range -55°C to +125°C
■ Capacitance To 4.7 µF
Class Y2 and Y4 available
Pages 12-22
www.spectrumcontrol.com/sfilter
■ Current ratings (max.) Barrier strip: 60 Amps
■ Voltage ratings (max.) From 100 VDC to 250 VAC,
60 Hz
■ Insertion loss range Effective insertion loss from
1 MHz to 200 MHz
■ Temperature range -55°C to +105°C
■ Capacitance .015 µF per line or .030 µF
per pair
Pages 23
www.spectrumcontrol.com/terblk
Power Entry
Modules
Power Entry Modules
Fused/Switched
and Fused
High Current
Feed-thru Filters
Pages 24-41
www.spectrumcontrol.com/pem
■ Design flexibility Bolt-in or snap-in mounting
Available in fused or
switched and fused
versions
■ Performance Ideally suited for products
that must conform to FCC
part 15 regulations
Meets over-voltage of
IEC 664 category II and
complies with IEC 950
Low leakage versions
available for medical
applications
■ Agency approvals UL recognized, CSA
certified, TÜV approved
(tested and found to be
in accordance with VDE
0565 Part 3)
www.spectrumcontrol.com/pemfsf
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
EMI Power Filters Selection Guide
Power Line
Filters
Applications
Commercial Custom
Assemblies
Digital equipment, industrial
equipment, UPS, inverters,
converters, automation
equipment, computerized
industrial washing machines,
and switching power supplies
Commercial & military avionics,
satellites, secured communications, ruggedized computers,
radar, electronic warfare, and
ground/air weapon systems
Telecommunications, cellular
base stations, medical
equipment, telephone
switching, traffic control
systems, industrial work
stations, servers, power
supplies, UPS, industrial
controls and welders
■ Rugged construction Designed to perform in
industrial environments
■ Rugged construction Designed to perform in
industrial environments
■ Rugged construction Designed to perform in
industrial environments
■ Design flexibility Available with fast-on, bolt-in
terminals or wire leads
■ Design flexibility Available with fast-on
or bolt-in terminals
■ Rugged construction Metal enclosures built
to withstand MIL-STD
environmental conditions
Single stage and dual stage
Single and dual stage
High performance in both
metal and plastic cases
Excellent attenuation for
high voltage impulse
■ Agency approvals Several styles are UL
recognized, CSA certified,
TÜV approved (tested and
found to be in accordance
with VDE 0565 Part 3)
Performance
Characteristics
Military/Aerospace
Multisection Filters
Digital equipment, personal
computers and peripherals,
measuring instruments,
medical, industrial, telecommunications equipment, factory
automation, UPS, vending
machines, elevators, and switch
mode power supplies
■ Performance Ideally suited for products
that must conform to FCC
part 15 regulations
Features/
Benefits
Three-Phase
Power Line
Filters
■ Current ratings (max) To 260 Amps
■ Voltage ratings (max.) From DC to 250 VAC,
60 Hz
■ Insertion loss range Effective filtering from
100 KHz to 30 MHz
■ Temperature range -25°C to +85°C
■ Leakage current range 0.35 mA to 3.0 mA max
Pages 52-87
www.spectrumcontrol.com/pline
Delta and Wye
configurations
■ Performance Ideally suited for products
that must conform to FCC
part 15 regulations
Both metal and plastic cases
provide high performance
Excellent attenuation for
high voltage impulse
■ Agency approvals Agency approvals pending
■ Current ratings (max) 3 Amp to 200 Amps
■ Voltage ratings (max.) 250 VAC to 440 VAC
■ Insertion loss range Effective filtering from
100 KHz to 30 MHz
■ Temperature range -40°C to +85°C
■ Leakage current range Standard and low leakage
designs available
Pages 88-97
www.spectrumcontrol.com/3pline
■ Design flexibility Standard catalog parts available Parts designed to meet
customers’ requirements
■ Performance EMI designs provide
excellent isolation and high
frequency performance
■ Military approvals Available to meet MIL-F15733 and MIL-STD-461
Military testing IAW MILSTD-202, MIL-STD-105
■ EMI design verification Equipment verification can
be accomplished through
Spectrum Control’s EMI
test lab
■ Current ratings (max.) Up to 100 Amps
■ Voltage ratings (max.) 400 VDC and 240 VAC
standard; custom voltage
ratings available
■ Insertion loss range Effective filtering from
10 KHz to 10 GHz
■ Temperature range -55°C to +125°C
Pages 98-105
www.spectrumcontrol.com/multi
■ Design flexibility Filters designed to meet customer’s circuit requirements
Transient protection
Circuit breakers
Voltage cut-off
Other options available
Provides quick and economical solutions to meet customers’ specific requirements
Increases speed-to-market
and decreases development
time
Designs optimized through
EMC verification
■ Agency approvals Designed to meet NEBS
and safety agency approvals
■ Current ratings (max.) Up to 250 Amps
■ Voltage ratings (max.) 400 VDC and 240 VAC
standard; custom voltage
ratings available
■ Insertion loss range Effective filtering from
10 KHz to 10 GHz
■ Temperature range -55°C to +125°C
■ Leakage current range Standard and low leakage
designs available
Pages 106-109
www.spectrumcontrol.com/comcus
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
5
Spectrum Control’s Expertise
Spectrum Control is unique in providing an integrated
approach to EMC problem solving by offering customer
consulting, diagnostic testing, design and manufacturing
services. As a fully integrated manufacturer, we are able
to respond to short lead times and develop cost-effective
solutions to satisfy your performance and budgetary needs.
Test
■
■
■
■
Spectrum Control’s Test Facility provides a total solution
for your compliance issues
In-house anechoic chamber and shielding room
NARTE certified engineering staff
Tests available for:
• European emission and immunity regulations
(CE Mark)
• FCC Part 15
• MIL standard testing
Design
■
■
■
■
In-house EMI and power conditioning specialists
Comprehensive computer modeling
Designs are “in-house” compliance verified
Custom assemblies:
• Incorporate EMI filtering, circuit breaker protection,
transient suppression, voltage cut-off, power factor
correction, harmonic suppression, remote sensing
and other options to meet your specific requirements
• Plug-and-play designs
• Reduce your time to market
• Lower your inventory needs
Manufacture
■
■
■
■
■
6
Flexible factories
Custom designs
Spectrum Control, Inc. ISO 9001 certified
Schedule sharing programs available
Vertically integrated supplier
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Spectrum Control’s Expertise
As a complete source of EMC solutions, Spectrum Control
combines state-of-the-art test facilities with proven expertise in the design and manufacture of EMI/RFI filtered
power products.
Spectrum Control offers:
Engineering Support – Our experienced engineering staff
will work closely with your design and manufacturing team
to provide rapid and cost-effective solutions meeting the
most stringent EMI requirements.
Reduced Lead Times and Volume Production – Our
vertical integration allows us to reduce lead times for both
prototype and production orders . . . ensuring on-time
delivery. This not only reduces your inventory, it saves
you time and money.
Custom Solutions – We offer maximum design expertise
and versatility to meet the need of any unique filtering
application. In addition, we’ll develop power conditioning
solutions with features such as back panels with EMI
filtering and surge protection, circuit breakers, LEDs
and voltage cut-off.
Full Qualification Testing – We offer a fully integrated
quality assurance process, as well as testing in compliance
with MIL-F-28861, MIL-F-15733, MIL-STD-202, and other
EMI specifications. Spectrum Control’s facilities have been
audited and qualified to MIL-I-45208 and are registered
to ISO 9001.
Customer Support Programs – We will work closely
with your organization to help improve the final design
and performance of your products, as well as increase
your manufacturing and operational efficiency. Spectrum
Control has instituted a variety of programs designed
to maximize these opportunities.
■
Flexible manufacturing to cut cycle times and
meet deadlines
■
EDI to streamline the transmitting of information
■
Inventory Management through flexible shipping
programs
■
Consignment/schedule sharing programs
to accommodate customers’ forecasts
■
Broader distribution base to make our products
more readily available and accommodate vendor
reduction plans
■
New product development geared to meeting
customer-specific requirements and targets
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
7
Application Guidelines
Need for EMI suppression
Global regulatory agencies have established limits to
the amount of noise that man-made electronic devices
can radiate or conduct. These regulations have gained
greater importance as the world’s electronic population
intensifies and the proximity of electronic devices
becomes closer.
Power Filter Installation
EMI can propagate through two basic
avenues: Conducted and Radiated
Conducted refers to events where the EMI energy flows
through power lines, data cables and other wiring that
carries functional data or power.
Radiated refers to energy that is propagated by
magnetic or electric fields, which originate from other
electronic or electrical systems.
INCORRECT
CORRECT
CABINET
POWER
INPUT
DENOTES
COUPLING
FROM NOISY
CIRCUITS
BACK TO
LINE
CABINET
DENOTES
COUPLING
FROM NOISY
CIRCUITS
BACK TO
LINE
POWER
INPUT
Interference types
There are two modes of conducted noise: differential
mode (symmetrical or normal mode) and common mode
(asymmetrical mode).
Differential mode interference signals are present on
one side of the line, referenced to the other. The currents
flow along one phase and return along another phase.
Common mode interference signals are present on both
sides of the line referenced to ground. The current flows
from the source to ground along the ground path and
returns along the phases.
Sources of EMI
Electromagnetic interference can occur naturally
or through electronic sources. Lightning discharges,
precipitation, sand and dust storms, and cosmic noise
are sources of natural EMI.
EMI generated from power electrical products cause
the most concern. These man-made sources, such as
power lines, rotating machinery, power supplies and
electronic transmission devices, all have their own
signatures and noise pollution.
EMI filters, insertion loss
and attenuation
Power line EMI filters are designed to attenuate
(or reduce) all radio frequency emissions or energy that
is above the applicable EMC specification. Most power
line EMI filters utilize inductor/capacitor “low pass” component configurations that pass all DC or low frequency
AC necessary energy and attenuate (suppress) higher
frequencies containing noise or unwanted energy.
8
LINE
FILTER
CLEAN
LINE
LINE FILTER
To insure a customer’s “in system” unit to unit
attenuation uniformity of power line filters, an insertion loss
production line test is performed by Spectrum Control, Inc.
Each of the specific frequencies is measured using
RF test equipment and the “reference signal level” of
each frequency is stored. Some systems sweep the entire
frequency range and store this “reference signal level”. The
filter to be measured, tested, or evaluated is then “inserted”
between the generator and receiver that established the
stored “reference signal level” on the RF test analyzer.
The measured difference without a filter (“the reference
signal level”) and with the filter “inserted” into the RF test
equipment/analyzer is defined as insertion loss. The unit
of measure for insertion loss is the decibel (dB). As noted
on most curves in this bulletin, as frequency increases,
the higher the insertion loss or dB value. The plot of
frequency versus dB value establishes the typical
insertion loss curve.
Installation Criteria
Proper installation of a filter network is critical to achieving
successful filtering of electromagnetic interference.
Spectrum Control recommends that power line filters be
installed where the power line enters the equipment. The
filter acts as a barrier between polluted energy and clean
energy going into your equipment. It is important that the
filter is connected to an effective ground plane and where
proximity does not couple radiated noise to the clean lines.
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Measurement Guidelines
Spectrum Control has the capability to perform a
wide range of tests for EMI filters. Unique custom testing
systems, designed by Spectrum Control assure the
accuracy required in today’s demanding environments.
Testing is performed by employing a 50 ohm source and
load impedance per MIL-STD-220. The individual filter
performance is stated in terms of insertion loss. Overall
attenuation reflects the filter’s interaction within the system.
Individual filter performance may differ from system to
system and each application should be verified through
system testing. Examples of various testing abilities and
configurations are outlined below.
Differential (Normal or Symmetrical)
Mode Insertion Loss
Differential mode noise is caused by non-sinusoidal
conduction of rectifiers and other switching devices
creating harmonic distortion.
This noise is predominant from the power frequency
to approximately 10 MHz. Since it follows conventional
current flow, it is considered to be of the same magnitude
but opposite phase of the other line. Spectrum Control
measures differential mode insertion loss in a 50 ohm
system with Balun transformers as shown.
Leakage Current
Leakage is a measurement of reactive current (capacitance) to ground per line. Spectrum Control uses the
following test setup for leakage current measurement.
TIES TO CHASSIS
OF DEVICE
DEVICE
UNDER
TEST
1
AC
SOURCE
2
0.15 µFD
1 NEUTRAL TEST
2 HIGH TEST
1.5 KΩ
v
IN ACCORDANCE WITH U.L. 1283 METHOD
AC Voltage Drop
AC voltage drop is defined as E in - E out = AC
voltage drop.
Spectrum Control uses the following circuit for AC voltage
drop testing:
A
DUT
(FILTER)
E1
BALUN
INSULTATED TABLE
E2
BALUN
FILTER
ØA
50Ω
FILTER
ØB
SIGNAL
GENERATOR
50Ω
RECEIVER
Common (Asymmetrical)
Mode Insertion Loss
E VD
Since common mode insertion loss is of the same
phase as the opposite line, they may not be of the
same magnitude, depending on the end system circuitry.
Spectrum Control tests common mode insertion loss on
each line in a 50 ohm system as shown.
LINE
DUT
(FILTER)
A
RS
LINE
50Ω
50Ω
FILTER
NEUT
DC Voltage Drop
DC voltage drop is performed on each line individually.
This test provides the total DC voltage drop for that line
of the filter. The following circuit is used in testing:
FILTER
ØC
RECEIVER
NEUT
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
9
EMC Testing Solutions
Spectrum Control is a solutions-oriented EMC test
corporation committed to effectively satisfying worldwide
EMC standards for commercial and military equipment.
Our EMC testing services offer you a flexible resource
to assist in product development by identifying and
correcting EMI susceptibility and/or emission problems.
Our commitment to our customers goes much further
than any other EMI filtered power products manufacturer.
Spectrum Control has a fully equipped EMC Test
Laboratory and experienced engineering staff ready
to solve your most demanding EMC challenges.
We can test your equipment, system or subsystem to
various domestic and international regulatory standards,
determine state of compliance, and develop the most
compact and cost-effective solution. These services (EMC
testing and compliance recommendations) are available
for a modest daily fee. It is not uncommon for clients leave
Spectrum Control’s EMC Test Laboratory with a prototype
in hand.
State-of-the-art Testing
■
■
■
■
■
Two test environments available: anechoic
chamber and shielded room
Baseline of device under test in ambient-free
anechoic chamber
Computer controlled pre-selected EMI receivers
with quasi-peak detection accumulate data for
displaying information in graphical or tabular formats
Fiber optic coupled video cameras for dynamic
test observation
Computer generated test data reduces time and
improves accuracy
Testing Capabilities
UL Underwriter’s Laboratories, UL 1283
MILITARY
MIL-STD-461 A/B/C/D and MIL-STD-1399
AUTOMOTIVE
SAE-J1113, SAE-J551
COMMERCIAL
FCC-Part 15
RTCA-DO-160 A/B/C
Boeing-16050-2
Bellcore-TR-NWT-001089
INTERNATIONAL
EN 55011 (CISPR 11)
EN 55014 (CISPR 14)
EN 55022 (CISPR 22)
IEC-1000-4-02 ESD
IEC-1000-4-03 RFI
IEC-1000-4-04 EFT
IEC-1000-4-05 Surge
10
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
EMC Testing Solutions
One of the most significant advantages of Spectrum
Control’s testing services lies in our experience and
expertise in evaluating, designing and producing products
for the suppression of EMI. Our approach to EMC testing
enables us to identify, as well as solve any problems or
potential problems found in your system. Spectrum’s
design and production engineers will work with your
engineering team to develop a filter solution that
eliminates your EMI problems.
Once we have identified an EMI failure, we will develop
a prototype design, integrate the EMC modification into
your device or system, and verify compliance to the
appropriate test specifications. Spectrum Control maintains
semi-automated and automated manufacturing facilities
to economically produce the modification installed during
testing. Through these capabilities your equipment will
leave Spectrum Control with a prototype, as well as
a fully compliant system.
Test
■
■
■
■
Spectrum Control Test Facility
will define compliance issues
In-house anechoic chamber
and shielded room
NARTE certified engineering staff
Test available for:
• European emission
and immunity regulations
• FCC Part 15
• MIL 461 Series
Design
■
■
■
■
■
In-house EMI specialists
Computer modeling
CAD systems internet accessible
Designs are “in-house”
compliance verified
Value-added designs:
• Incorporate circuits and
additional components
• Ease of production assembly
• Lower inventory needs
Manufacture
■
■
■
■
■
■
Flexible operations
Custom designs built in U.S.A.
ISO 9001 certified facilities
Workmanship MIL-STD-2000
certified
Schedule sharing programs
available
Vertically integrated
EMI filter supplier
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
11
High Current
DC Single Line
Feed-thru Series
Features
■
■
■
■
Single Line Filters
■
■
■
■
■
Voltage Rating 130VDC
C Configuration with Class Y4 capacitors
Current rating up to 300 Amps
Operating Temperature Range: -40C to +85C
Excellent filtering in compact package
Bolt-in style with D-shaped bushing for easy installation
Low cost EMI solution
Design flexibility
UL and Semko approved
Applications
■
■
■
■
■
■
Telecommunications (cellular base stations,
telephone switching racks, etc.)
Power supplies
Medical Equipment
C.O.T.S. (Commercial-Off-The-Shelf) Military
Industrial equipment controls
Data Transmission Equipment
Specifications
Part
Number
52-226-011-10
52-226-011-16
52-226-011-32
52-226-011-63
52-226-011-100
52-226-011-200
52-226-011-250
52-226-011-300
52-226-021-16
52-226-021-32
52-226-031-63
52-226-021-100
52-226-021-200
52-226-021-250
52-226-021-300
52-226-031-16
52-226-031-32
52-226-031-63
52-226-031-100
52-226-031-200
52-226-031-250
52-226-031-300
52-226-041-16
52-226-041-32
52-226-041-63
52-226-041-100
52-226-041-200
Rated
Current
10A
16A
32A
63A
100A
200A
250A
300A
16A
32A
63A
100A
200A
250A
300A
16A
32A
63A
100A
200A
250A
300A
16A
32A
63A
100A
200A
Min.
Cap.
.01MHz
10nF
.10MHz
Minimum Insertion Loss (db)*
1MHz
10MHz
100MHz
1000MHz
–
4
21
41
60
2
15
34
53
74
100nF
5
21
40
60
85
47nF
2
15
34
53
74
100nF
5
21
40
60
85
47nF
–
470nF
2
16
33
52
75
90
100nF
–
5
21
40
60
85
470nF
2
16
33
52
75
1000nF
6
20
40
60
85
470nF
2
16
33
52
75
1000nF
4700nF
6
15
20
35
40
54
60
74
85
90
90
* Optimum performance with proper installation
12
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
High Current
DC Single Line
Feed-thru Series
B
E
WORKORDER NO.
C
Single Line Filters
F
D
DATE CODE
SINGLE "D"
MOUNTING FLAT
.025 (.64) SHOULDER
A
Dimensions
Part Number
52-226-011-10
52-226-011-16
52-226-011-32
52-226-011-63
52-226-011-100
52-226-011-200
52-226-011-250
52-226-011-300
52-226-021-16
52-226-021-32
52-226-031-63
52-226-021-100
52-226-021-200
52-226-021-250
52-226-021-300
52-226-031-16
52-226-031-32
52-226-031-63
52-226-031-100
52-226-031-200
52-226-031-250
52-226-031-300
52-226-041-16
52-226-041-32
52-226-041-63
52-226-041-100
52-226-041-200
A
B
C
D
E
2.24 (57)
0.39 (10)
0.51 (13)
0.56 (14.29)
0.63 (16)
2.48 (63)
0.47 (12)
0.67 (17)
0.75 (19.05)
0.71 (18)
3.78 (96)
4.45 (113)
5.12 (130)
0.55 (14)
0.63 (16)
0.87 (22)
1 (25.40)
1.18 (30)
1.06 (27)
1.25 (31.75)
1.02 (26)
1.26 (32)
1.57 (40)
1.57 (40)
2 (50.80)
1.81 (46)
1.65 (42)
5.83 (148)
0.75 (19)
F
2.95 (75)
0.47 (12)
0.67 (17)
0.75 (19.05)
0.71 (18)
3.78 (96)
4.45 (113)
5.12 (130)
0.55 (14)
0.63 (16)
0.87 (22)
1 (25.40)
1.06 (27)
1.25 (31.75)
1.02 (26)
1.26 (32)
1.57 (40)
1.57 (40)
2 (50.80)
1.81 (46)
6.30 (160)
0.75 (19)
0.71 (18)
1.30 (33)
1.18 (30)
1.30 (33)
2.13 (54)
2.95 (75)
0.47 (12)
0.67 (17)
0.75 (19.05)
0.71 (18)
3.78 (96)
4.45 (113)
5.79 (147)
0.55 (14)
0.63 (16)
0.87 (22)
1 (25.40)
1.25 (31.75)
1.5 (38.10)
1.02 (26)
1.26 (32)
1.57 (40)
1.30 (33)
1.97 (50)
2 (50.80)
1.81 (46)
2.83 (72)
7.01 (178)
3.23 (82)
3.98 (101)
5.24 (133)
6.50 (165)
0.75 (19)
0.63 (16)
0.75 (19)
1.06 (27)
1.57 (40)
1.06 (27)
1.57 (40)
1.25 (31.75)
1.5 (38.10)
2 (50.80)
0.71 (18)
1.02 (26)
1.26 (32)
1.57 (40)
1.18 (30)
1.30 (33)
1.97 (50)
2.68 (68)
Dimensions in inches (mm)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
13
High Current
DC Single Line
Pi Series
Features
■
■
■
■
Single Line Filters
■
■
■
Voltage Rating 130VDC
Pi Configuration with Class Y4 capacitors
Current rating up to 200 Amps
Excellent filtering in compact package
Bolt-in style with D-shaped bushing for easy installation
Low cost EMI solution
UL and Semko approved
Applications
■
■
■
■
■
■
Telecommunications (cellular base stations,
telephone switching racks, etc.)
Power supplies
Medical Equipment
C.O.T.S. (Commercial-Off-The-Shelf) Military
Industrial equipment controls
Data Transmission Equipment
Circuit Diagram
Specifications
Part
Number
Standard Performance
52-226-020-10
52-226-020-16
52-226-020-32
52-226-020-63
52-226-020-100
52-226-020-200
High Performance
52-226-029-10
52-226-029-16
52-226-029-32
52-226-029-63
52-226-029-100
52-226-029-200
Rated
Current
10A
16A
32A
63A
100A
200A
10A
16A
32A
63A
100A
200A
Min.
Cap. (2X)
10nF
.01MHz
–
.10MHz
Minimum Insertion Loss (db) *
1MHz
10MHz
100MHz
0.5
8
10
27
23
35
23
67
70
60
470nF
4
7
2
8
21
23
100nF
–
8
25
75
470nF
1000nF
4700nF
4
8
20
21
26
40
35
57
85
70
73
90
100nF
30
1000MHz
70
50
90
90
90
90
* Optimum performance with proper installation
14
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
High Current
Single Line Filters
DC Single Line
Pi Series
A
B
F
E
C
D
SINGLE "D"
MOUNTING FLAT
DATE CODE
WORKORDER NO.
.025 (.64) SHOULDER
Dimensions
Part Number
Standard Performance
52-226-020-10
52-226-020-16
52-226-020-32
52-226-020-63
52-226-020-100
52-226-020-200
High Performance
52-226-029-10
52-226-029-16
52-226-029-32
52-226-029-63
52-226-029-100
52-226-029-200
A
B
C
D
0.47 (12)
0.67 (17)
0.75 (19.05)
0.55 (14)
0.63 (16)
0.75 (19)
0.87 (22)
1 (25.40)
1.25 (31.75)
1.50 (38.10)
0.47 (12)
0.67 (17)
3.54 (90)
3.86 (98)
6.30 (160)
7.24 (184)
8.23 (209)
1.06 (27)
5.12 (130)
5.47 (139)
6.81 (173)
8.98 (228)
11 (279)
0.63 (16)
0.75 (19)
1.06 (27)
1.57 (40)
0.75 (19.05)
1.25 (31.75)
1.50 (38.10)
2 (50.80)
E
F
0.63 (16)
1.93 (49)
0.71 (18)
2.09 (53)
1.02 (26)
1.26 (32)
1.57 (40)
3.70 (94)
4.09 (104)
4.41 (112)
0.63 (16)
3.50 (89)
0.71 (18)
3.70 (94)
1.02 (26)
1.26 (32)
1.57 (40)
4.13 (105)
5.71 (145)
7.17 (182)
Dimensions in inches (mm)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
15
High Current
AC Single Line
Feed-thru Series
Features
■
■
■
■
■
Single Line Filters
■
■
■
Voltage Rating 250VAC
C Configuration with Class Y2 capacitors
Current rating up to 300 Amps
Excellent filtering in compact package
Bolt-in style with D-shaped bushing for easy installation
Low cost EMI solution
Design flexibility
UL and Semko approvals pending
Applications
■
■
■
■
■
■
Telecommunications (cellular base stations,
telephone switching racks, etc.)
Power supplies
Medical Equipment
C.O.T.S. (Commercial-Off-The-Shelf) Military
Industrial equipment controls
Data Transmission Equipment
Specifications
Part
Number
52-226-016-10
52-226-016-16
52-226-016-32
52-226-016-63
52-226-016-100
52-226-016-200
52-226-016-250
52-226-016-300
52-226-026-10
52-226-026-16
52-226-026-32
52-226-026-63
52-226-026-100
52-226-026-200
52-226-026-250
52-226-026-300
52-226-036-16
52-226-036-32
52-226-036-63
52-226-036-100
52-226-036-200
52-226-036-250
52-226-036-300
52-226-046-16
52-226-046-32
52-226-046-63
52-226-046-100
52-226-046-200
52-226-046-250
52-226-046-300
Rated
Current
Min.
Cap.
10A
16A
32A
63A
100A
200A
250A
300A
10A
16A
32A
63A
100A
200A
250A
300A
16A
32A
63A
100A
200A
250A
300A
16A
32A
63A
100A
200A
250A
300A
2.2nF
.01MHz
.10MHz
Minimum Insertion Loss (db) *
1MHz
10MHz
100MHz
1000MHz
-
9
30
45
4.7nF
–
2
15
34
54
10nF
47nF
2
4
15
21
34
41
53
60
74
100nF
5
21
40
60
85
2
15
34
54
4
21
41
60
4.7nF
10nF
–
–
47nF
100nF
2
5
15
21
34
40
53
60
74
85
220nF
10
27
47
67
90
47nF
33nF
100nF
220nF
2
3
5
10
15
16
21
27
34
35
40
47
16
33
52
75
2
5
2
10
16
21
15
27
33
40
34
47
52
60
53
67
75
6
20
40
60
85
470nF
100nF
47nF
220nF
470nF
2
–
53
60
67
74
90
85
90
85
74
90
1000nF
* Optimum performance with proper installation
16
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
High Current
AC Single Line
Feed-thru Series
B
F
WORKORDER NO.
Single Line Filters
C
E
D
SINGLE "D"
MOUNTING FLAT
DATE CODE
.025 (.64) SHOULDER
A
Dimensions
Part Number
52-226-016-10
52-226-016-16
52-226-016-32
52-226-016-63
52-226-016-100
52-226-016-200
52-226-016-250
52-226-016-300
52-226-026-10
52-226-026-16
52-226-026-32
52-226-026-63
52-226-026-100
52-226-026-200
52-226-026-250
52-226-026-300
52-226-036-16
52-226-036-32
52-226-036-63
52-226-036-100
52-226-036-200
52-226-036-250
52-226-036-300
52-226-046-16
52-226-046-32
52-226-046-63
52-226-046-100
52-226-046-200
52-226-046-250
52-226-046-300
A
B
C
D
E
2.24 (57)
0.39 (10)
0.51 (13)
0.56 (14.29)
0.63 (16)
2.48 (63)
0.47 (12)
0.67 (17)
0.75 (19.05)
0.71 (18)
3.78 (96)
4.45 (113)
5.12 (130)
0.55 (14)
0.63 (16)
0.87 (22)
1 (25.40)
1.25 (31.75)
1.5 (38.10)
1.02 (26)
1.26 (32)
1.57 (40)
1.18 (30)
1.57 (40)
2 (50.80)
1.81 (46)
1.65 (42)
5.83 (148)
0.75 (19)
1.06 (27)
F
0.71 (18)
1.30 (33)
2.24 (57)
0.39 (10)
0.51 (13)
0.56 (14.29)
0.63 (16)
2.48 (63)
0.47 (12)
0.67 (17)
0.75 (19.05)
0.71 (18)
3.78 (96)
4.45 (113)
5.12 (130)
0.55 (14)
0.63 (16)
0.87 (22)
1 (25.40)
1.25 (31.75)
1.5 (38.10)
1.02 (26)
1.26 (32)
1.57 (40)
1.18 (30)
1.57 (40)
2 (50.80)
1.81 (46)
1.65 (42)
5.83 (148)
0.75 (19)
1.06 (27)
0.71 (18)
1.30 (33)
2.95 (75)
0.47 (12)
0.67 (17)
0.75 (19.05)
0.71 (18)
3.78 (96)
4.57 (116)
5.79 (147)
0.55 (14)
0.87 (22)
1.06 (27)
1 (25.40)
1.02 (26)
1.26 (32)
1.57 (40)
1.30 (33)
1.97 (50)
2 (50.80)
1.81 (46)
2.13 (54)
0.87 (22)
0.67 (17)
1 (25.40)
0.71 (18)
1.18 (30)
1.06 (27)
1.25 (31.75)
1.5 (38.10)
1.02 (26)
1.26 (32)
1.57 (40)
1.30 (33)
1.81 (46)
2.13 (54)
0.75 (19)
6.30 (160)
3.03 (77)
2.95 (75)
4.45 (113)
5.24 (133)
5.79 (147)
6.30 (160)
0.55 (14)
0.47 (12)
0.63 (16)
0.75 (19)
1.57 (40)
1.57 (40)
1.5 (38.10)
2 (50.80)
1.18 (30)
1.97 (50)
Dimensions in inches (mm)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
17
High Current
AC Single Line
Pi Series
Features
■
■
■
■
Single Line Filters
■
■
■
■
Voltage Rating 250VAC
Pi Configuration with Class Y2 capacitors
Current rating up to 300 Amps
Excellent filtering in compact package
Bolt-in style with D-shaped bushing for easy installation
Low cost EMI solution
Design flexibility
UL and Semko approvals pending
Circuit Diagram
Applications
■
■
■
■
■
■
Telecommunications (cellular base stations,
telephone switching racks, etc.)
Power supplies
Medical Equipment
C.O.T.S. (Commercial-Off-The-Shelf) Military
Industrial equipment controls
Data Transmission Equipment
Specifications
Part
Number
Standard Performance
52-226-037-10
52-226-037-16
52-226-037-32
52-226-037-63
52-226-037-100
52-226-037-200
52-226-037-250
52-226-037-300
High Performance
52-226-019-10
52-226-019-16
52-226-019-32
52-226-019-63
52-226-019-100
52-226-019-200
52-226-019-250
52-226-019-300
Rated
Current
Min.
Cap. (2X)
10A
16A
32A
63A
100A
200A
250A
300A
4.7nF
10A
16A
32A
63A
100A
200A
250A
300A
10nF
.01MHz
–
47nF
100nF
1
10nF
22nF
–
.10MHz
Minimum Insertion Loss (db) *
1MHz
10MHz
100MHz
–
4
19
77
1
8
22
50
4
8
21
25
52
73
80
9
26
75
1
9
30
3
15
47
27
39
75
150nF
1
12
470nF
4
21
57
85
1000MHz
90
90
80
90
90
* Optimum performance with proper installation
18
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
High Current
AC Single Line
Pi Series
Single Line Filters
A
B
F
E
C
D
SINGLE "D"
MOUNTING FLAT
DATE CODE
WORKORDER NO.
.025 (.64) SHOULDER
Dimensions
Part Number
Standard Performance
52-226-037-10
52-226-037-16
52-226-037-32
52-226-037-63
52-226-037-100
52-226-037-200
52-226-037-250
52-226-037-300
High Performance
52-226-019-10
52-226-019-16
52-226-019-32
52-226-019-63
52-226-019-100
52-226-019-200
52-226-019-250
52-226-019-300
A
B
C
D
E
F
0.47 (12)
0.67 (17)
0.75 (19.05)
0.63 (16)
0.71 (18)
2.24 (57)
2.40 (61)
0.55 (14)
0.63 (16)
0.87 (22)
1 (25.40)
1.25 (31.75)
1.02 (26)
1.26 (32)
1.57 (40)
3.7 (94)
4.09 (104)
4.41 (112)
1.81 (46)
3.66 (93)
3.86 (98)
4.17 (106)
6.30 (160)
7.24 (184)
8.23 (209)
7.87 (200)
0.75 (19)
1.06 (27)
1.57 (40)
1.5 (38.10)
4.21 (107)
0.47 (12)
0.67 (17)
0.75 (19.05)
0.63 (16)
2.6 (66)
4.57 (116)
0.55 (14)
0.87 (22)
1 (25.40)
0.71 (18)
2.72 (69)
6.81 (173)
8.98 (228)
9.57 (243)
0.63 (16)
1.06 (27)
1.25 (31.75)
1.5 (38.10)
1.02 (26)
1.26 (32)
4.13 (105)
5.71 (145)
5.75 (146)
1.57 (40)
2 (50.80)
1.57 (40)
10.5 (267)
0.75 (19)
6.30 (160)
Dimensions in inches (mm)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
19
High Current
Single Line
Feed-thru Filters
High current single line feed-thru filters from Spectrum
Control are ideal to meet broad frequency applications.
This series filters EMI/RFI with 150-500 Amp current with
AC and DC voltages. These filters are ideal for cellular
base stations, telephone switching stations and high
voltage power supply applications.
Single Line Filters
Features
■
■
■
■
■
■
■
■
■
■
■
■
Ideal for high current applications
Excellent filtering in a compact, durable package
Bolt-in style for easy installation
Current ratings to 500 Amps
Voltage ratings up to 1000VDC and 240VAC
Available with single, dual, and triple feed-thrus
Various capacitance ratings (up to 1.68 µF)
Rugged construction for indoor and outdoor
applications
Various mounting brackets available
Low cost EMI solution
Design flexibility
Custom mechanical configurations available
■
■
20
Temperature Range:
Amps
Amps
Amps
Amps
Amps
Amps
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
10
12
12
14
16
18
mm
mm
mm
mm
mm
mm
-25°C to 85°C
Typical Insertion Loss (dB)
90
80
70
50
Telecommunications (cellular base stations,
telephone switching racks, etc.)
Power supplies
Servers
Part
Number
Current Ratings/Bolt Size: 150
200
250
300
400
500
60
Applications
■
Electrical Specifications
1.68µF
40
0.04µF
30
0.03µF
0.02µF
20
0.01µF
10
0
0.01
0.1
1
10
Frequency (MHz)
100
Figure
Voltage Rating @
-40C to +85C
Current
Rating
Capacitance
Value
52-226-001
A
50VDC Max.
300 Amps
0.02 µF min. @ 50VDC
52-226-002
B
50VDC Max.
300 Amps
0.02 µF min. @ 50VDC
52-226-006
C
50VDC Max.
150 Amps
0.02 µF min. @ 50VDC
52-226-008
D
75VDC Max.
200 Amps
0.02 µF min. @ 50VDC
52-226-009
E
50VDC Max.
150 Amps
0.02 µF min. @ 50VDC
52-267-008
F
200VDC Max.
200 Amps
0.02 µF min. @ 40VDC
52-226-004
F
200VDC Max./240 VAC
200 Amps
1.68 µF min. @ 50VDC
52-226-015
G
200VDC Max./240 VAC
200 Amps
1.68 uF min. @ 50VDC
52-267-002
H
200VDC Max./240 VAC
200 Amps
1.68 µF min. @ 40VDC
52-267-003
J
200VDC Max./240 VAC
200 Amps
1.68 µF min. @ 40VDC
52-267-009
F
200VDC Max./240 VAC
60 Amps
1.68 µF min. @ 50VDC
52-267-010
K
200VDC Max./240 VAC
250 Amps
1.68 µF min. @ 40VDC
52-267-011
K
200VDC Max./240 VAC
100 Amps
1.68 µF min. @ 40VDC
52-267-012
K
250VDC Max.
100 Amps
1.00 µF+20% @ 40VDC
1000
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
High Current
Single Line
Feed-thru Filters
Mechanical Dimensions
Figure A
Figure B
4.67 (118.6)
4.20 (106.6)
.314 (8.0) (2x)
4.669 (118.6)
.236 (6.0) (2x)
4.196 (106.6)
.236 (6.0) (2x)
.314 (8.0) (2x)
1.221 (31.0)
1.220
(31.0)
1.811 (46.0)
1.498
(38.0)
1.811
(46.0)
2.441
(62.0)
Ø .204 ± .005 THRU (4x)
(5.2 ± .13)
1.587
(40.3)
1.496
(38.0)
1.586
(40.3)
Single Line Filters
2.441 (62.0)
Ø .204 (5.2)
THRU (4x)
SCI 24-0058-4800
SCI 24-0058-4800
M14 x 2.0 - 6g STUD (2x)
1.295 ± .02 (2x)
(32.9 ± 0.6)
M14 x 2.0-6g STUD (2x)
1.295 ± .02
(32.9 ± 0.6) (2x)
SCI 22-0833-0100
BRACKET ASSEMBLY
2.047 ± .02
(52.0 ± 0.6)
2.598
(66.0)
MAX.
4.015 ± .02
(102.0 ± 0.6)
.276 ± .016
(7 ± .4)
.063
(1.6)
.063
(1.6)
2.598
(66.0) MAX.
4.015 ± .02
(102.0 ± 0.6)
SCI 24-0058-4800
.125 (3.18) TYP.
FOR LABEL
LOCATION
.125 (3.18) TYP.
FOR LABEL LOCATION
DATE CODE
DATE CODE
.826 (21.0)
MIN. THRD.
LENGTH
Ø1.50
(38.8)
SCI 24-0058-4700 (3x)
45˚ CHAMFER
BOTH ENDS
.826 (21.0)
MIN. THRD. LENGTH
Figure C
Ø 1.25 (31.75)
Figure D
Ø .874 (22.20) (2x)
Ø .874 (22.20) (2x)
5.393 (137.0)
5.039 (128.0)
.177 (4.5) (2x)
.826 (21.0)
1.299
(33.0)
5.393 (137.0)
5.039 (128.0)
.177 (4.5) (2x)
.177 (4.5) (2x)
.177 (4.5) (2x)
.826 (21.0)
1.299
(33.0)
1.652 (42.0)
1.652 (42.0)
1.984
(49.5)
1.496
(38.0)
Ø .204 ± .005
(5.2 ± .13) THRU
.807 (20.5)
2.0
.429 (10.9)
1.413 ± .002
(35.9 ± 0.6)
2.598
(66.0) MAX.
Ø .204 ± .005
(5.2 ± .13) THRU (4x)
Ø .118 ± .005
(3.0 ± .13)
Ø .118 ± .005
(3.0 ± .13)
M10 x 1.5-6g STUD-BRASS (UNPLATED)
M10 x 1.5-6g STUD
TIN PLATED BRASS
.248 (6.3) (2x)
1.295 ± .02
(32.9 ± 0.6) (2x)
1.496
(38.0)
.807 (20.5)
1.984
(49.5)
M10 x 1.5-6g STUD
TIN PLATED BRASS
1.295 ± .02
(32.9 ± 0.6) (2x)
.248 [6.3] (2x)
.063 (1.6)
.429 [10.9]
1.421 ± .012
[36.1 ± 0.3]
1.89 0± .02
(48.0 ± 0.6) MAX.
4.015 ± .02
(102.0 ± 0.6)
2.717 ± .02
(89.0 ± .6)
.063 (1.6)
7.0
MIN.
.826 (21.0) MIN.
.826 (21.0) MIN.
DATE CODE
DATE CODE
M10 x 1.5-6g STUD-BRASS (UNPLATED)
Figure E
Ø 1.25
(31.75)
M10 x 1.5-6g STUD
TIN PLATED BRASS
Ø 1.25
(31.75)
Figure F
Ø .874 (22.20) (2x)
5.393 (137.0)
5.039 (128.0)
.177 (4.5) (2x)
3.406
(86.5)
.177 (4.5) (2x)
0.197
(5.00)
.826 (21.0)
1.299
(33.0)
3.799
(96.5)
0.197
(5.00)
1.801
(45.75)
0.197
(5.00)
1.652 (42.0)
1.984
(49.5)
1.496
(38.0)
.807 (20.5)
1.295 ± .02
(32.9 ± 0.6) (2x)
Ø .118 ± .005
(3.0 ± .13)
Ø .204 ± .005
(5.2 ± .13) THRU (4x)
(6x) ø 0.185 ±0.004
(4.70 ±0.1)
(2x) ø1.378 ± 0.004
(MAX) (35.0 ±0.1)
M10 x 1.5-6g STUD
TIN PLATED BRASS
0.689
(17.5)
1.909 ±0.02
(48.5 ±0.5)
1.378
(35.0)
1.772
(45.0)
1.053 ±0.01
(26.75 ±0.3)
M10x1.5 – 6g STUDS
1.102 ±0.02
(28.0 ± .5)
.063 (1.6)
2.598
(66.0) MAX.
.961 ±0.02
(24.4 ±0.5)
4.015 ± .02
(102.0 ± .6)
3.976 ±0.02
(101.0 ±0.5)
.921 (23.4)
.047
(1.2)
SQ 52 - 226 - 004
200VDC 200A XXXX
1.890
(48.0) 1.969 ±0.02
(50.0 ±0.5)
.826 (21.0) MIN.
Ø 1.25
(31.75)
Dimensions in inches (mm)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
21
High Current
Single Line
Feed-thru Filters
Figure G
Figure H
3.956
(100.5)
1.702
(43.25)
3.405
(86.5)
1.506
(38.25)
Ø 1.378
(35.0)
2.955 (75.0)
1.378
(35.0)
.964
(25.4)
Single Line Filters
1.023
(26.0)
1.929
(49.0)
5.516 (140.0)
PEM CLS-M4-1
(6 PLACES)
1.909 ± 1.968
(48.5 ± 50)
2.726 (69.2)
1.363 (34.6)
1.259
(32.0)
.078
(2.0)
MAX.
2.092 (53.10)
1.382 (35.08)
5.520 (140.10)
.248
(6.3)
1.889
(48.0)
1.52 (.060)
1.777 (45.10)
3.428 (87.00)
2.719 (69.00)
RED
BLACK
7.480 + .787/-0
(190.0 + 20.0/-0)
8.858 + .787/-0
(225.0 + 20.0/-0)
10.433 + .78/-0
(265.0 + 20.0/-0)
.984
(25.0)
M10 x 1.5-6g STUD
Figure J
Figure K
3.799 (96.5)
4.807 (122.00)
3.406 (86.50)
1.801
(15.75)
2.403 (51.00)
Ø .283 (7.2) (2x)
2.955 (75.0)
0.197 (5.0)
0.197 (5.0)
0.689 (17.5)
PEM BSOS-M4-6 (6x)
1.378 (35.00)
ø 0.185±0.004
(6x) (4.70±0.1)
2.285 (58.00)
.197
(5.0)
4.570 (116.00)
(MAX) ø 1.378±0.004
(2x) (35.0±0.1)
5.516 (140.0)
2.726 (69.20)
1.772 (45.0)
1.909±0.02
(48.5±0.5)
1.053±0.01
(26.75±0.3)
1.363 (34.60)
0.610±0.02
(15.5±0.5)
2.092 (53.10)
1.382 (35.08)
5.520 (140.10)
1.777 (45.10)
3.428 (87.00)
2.719 (69.00)
.080 (1.52)
.047 (1.2)
0.118±0.02
(3±0.5)
3.19±0.16
(81.0±4)
.039 (1.00)
1.890 (48.0)
1.969±0.02
(50.0±0.5)
M10 x 1.5-6g STUD
Dimensions in inches (mm)
22
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
High Current
Filtered Terminal Blocks
Features
■
■
■
Ideal for high current applications
Design flexibility
Available in 2 x 2 thru 2 x 6 positions
UL approved
Specifications
Applications
ELECTRICAL
Voltage rating:
Capacitance:
Telecommunications switching networks
■ Cellular base stations
■ Power supplies
■ UPS
■ Instrumentation
■ High reliability radar and transmission systems
■ Industrial controls
■ Power distribution
■
4.600 (116.8)
Dielectric
withstanding voltage: 1000VDC for 1 minute
Current rating:
60 Amps max per terminal
Typical Insertion Loss — dB:
In 50 Ohm Circuit
1
5
10
50
8-32 THREADED
INSERTS (4X)
1.625
(41.3)
.65 MIN (16.5) (6X)
1.10 (27.9)
.80 MIN (20.3)
.75 (19.0) (5X)
.172 (4.3) (4X)
70
100
160
200
MHz......... 36
MHz......... 33
MHz......... 25
MHz......... 25
US .200: (5.08 mm)
AWG #12-26
steel, zinc chromate plate
.05" (1.30 mm) contact hole
UL rated 94VO polyamide
2.5 in.-lbs. max. (28 Ncm)
Brass, tin-plated
* For filter elements with additional capacitance values,
consult factory.
1.685 2.025
(42.8) (51.4)
2.625 2.025 .75 (19.0)
(66.7) (51.4)
PANEL CUTOUT
4.6 (116.8)
5.0 (127)
5.0 (127)
5.6 (142.2)
Part
Number
MHz....... 8
MHz....... 24
MHz....... 32
MHz....... 38
MECHANICAL
Center spacing:
Wire size:
Screw material:
Recommended PCB
hole diameter:
Molded material:
Tightening torque:
Terminal:
R.125 (3.2) (4X)
1.15 (29.1)
100 VDC per terminal
.015µF* +80% / -20% per cap
.030µF +80% / -20% per pair
Filtered Terminal Blocks
■
Number of
Terminals
in.
A
(mm)
in.
B
(mm)
in.
C
(mm)
52-1013-102
2x2
2.60
66.04
2.00
50.80
1.66
42.16
52-1013-103
2x3
3.35
85.09
2.75
69.85
2.41
61.21
52-1013-104
2x4
4.10
104.14
3.50
88.90
3.16
80.25
52-1013-105
2x5
4.85
123.19
4.25
107.95
3.91
99.31
52-1013-106
2x6
5.60
142.24
5.00
127.00
4.66
118.36
Dimensions in inches (mm)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-835-1650 • Fax: 814-835-1651 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
23
Power Entry Modules
Bolt-in Rear Terminals
60-BPR & BPS Series
Features
Power Entry Modules
■
■
■
■
■
■
■
Tested and found to be
IAW VDE 0565 Part 3.
Ideally suited for products that must
conform to FCC part 15 regulations
Metal case offers high performance
Meets over voltage of IEC 664 category II
and complies with IEC 950
Uses IEC connector that meets most safety standards
Solder lug and Fast-on tab terminals available
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 25)
UL approved low leakage version also available
Circuit Diagram
3
1
Applications
■
■
■
■
CY
L1
CX
E
E
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
CY
2
4
Specifications
Model*
Rated Voltage
(@ 50/60Hz)
Rated
Current
60-XXX-010-3-2
60-XXX-010-3-4
250VAC
Leakage Current
(Max.)
CY
Capacitance
0.35mA
2200pF ± 20%
0.50mA
3300pF ± 20%
60-XXX-010-5-4
0.35mA
250VAC
2200pF ± 20%
0.50mA
3300pF ± 20%
60-XXX-020-5-4
0.35mA
250VAC
2200pF ± 20%
0.50mA
3300pF ± 20%
60-XXX-030-5-4
0.35mA
250VAC
2200pF ± 20%
0.50mA
3300pF ± 20%
0.35mA
2200pF ± 20%
0.50mA
3300pF ± 20%
0.35mA
2200pF ± 20%
60-XXX-060-5-4
0.53mH
45°C
.022uF ± 20%
0.26mH
45°C
.01uF ± 20%
0.15mH
45°C
.022uF ± 20%
.022uF ± 20%
.047uF ± 20%
250VAC
10A
250VAC
15A
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 45g
Input: Compatible with IEC-320
24
30°C
.022uF ± 20%
.047uF ± 20%
6A
60-XXX-060-5-2
60-BPR-150-3-11
1.2mH
.022uF ± 20%
.047uF ± 20%
60-XXX-060-3-2
60-XXX-100-5-2
30°C
.022uF ± 20%
.047uF ± 20%
3A
60-XXX-030-5-2
60-XXX-100-3-2
2.4mH
.022uF ± 20%
.047uF ± 20%
60-XXX-030-3-2
60-XXX-060-3-4
30°C
.022uF ± 20%
.047uF ± 20%
2A
60-XXX-020-5-2
60-XXX-030-3-4
6.0mH
.022uF ± 20%
.047uF ± 20%
60-XXX-020-3-2
60-XXX-020-3-4
Temperature
Rise (Max.)
.047uF ± 20%
1A
60-XXX-010-5-2
Inductance
(L1)
CX
* Substitute BPR or BPS for XXX
BPS - Solder lug terminals
BPR - Fast-on tab terminals
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Entry Modules
Bolt-in Rear Terminals
60-BPR & BPS Series
Temperature Characteristics
0.807
(20.5)
Power Entry Modules
120
Current (%)
100
.944 (24)
80
.846
(21.5)
60
1.476 (37.5)
(2x) .142
(3.6)
40
1.967
(50)
0
20
30
40
50
60
70
Ambient Temperature (°C)
80
.157
(4)
1.10
(28)
1.181
(30)
1.573
(40)
20
* General tolerance
± .012 (0.3)
90
Dimensions in inches (mm)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
50Ω
80
70
70
60-BPX-010-5-X
60-BPX-010-5-X
Insertion Loss (dB)
60
50
40
60-BPX-020-5-X
30
60-BPX-030-5-X
20
60
50
40
60-BPX-020-5-X
30
60-BPX-030-5-X
20
10
10
0
0.1
0.2
0.5
1
2
5
10
20
0
0.1
50
0.2
0.5
1
5
10
20
50
60-BPX-060;-100
60-BPX-060;-100
80
80
70
70
Insertion Loss (dB)
60
60-BPX-060-5-X
50
40
30
60-BPX-100-5-X
20
60-BPX-060-X-4
60
50
60-BPX-060-X-2
40
60-BPX-100-X-2
30
20
10
10
0
0.1
2
Frequency (MHz)
Frequency (MHz)
Insertion Loss (dB)
50Ω
Level
Meter
50Ω
60-BPX-010;-020;-030
60-BPX-010;-020;-030
80
Insertion Loss (dB)
2.263 (57.5)
.252
(6.4)
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
25
Power Entry Modules
Bolt-in Right Angle Terminals
60-BPF Series
Features
Power Entry Modules
■
■
■
■
■
■
■
■
Tested and found to be
IAW VDE 0565 Part 3.
Ideally suited for products that must
conform to FCC part 15 regulations
Metal case offers high performance
Meets over voltage of IEC 664 category II
and complies with IEC 950
Uses IEC connector that meets most safety standards
PCB mounting types available (see page 54)
Length under tab is shortened for small spaces
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 27)
UL approved low leakage version also available
■
■
■
3
1
CY
L1
CX
Applications
■
Circuit Diagram
E
E
CY
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
2
4
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
60-BPF-010-3-2
60-BPF-010-3-4
250VAC
Leakage Current
(Max.)
CY
Capacitance
0.35mA
2200pF ± 20%
0.50mA
3300pF ± 20%
60-BPF-010-5-4
0.35mA
250VAC
2200pF ± 20%
0.50mA
3300pF ± 20%
60-BPF-020-5-4
30°C
2.4mH
30°C
1.2mH
30°C
0.53mH
45°C
.022uF ± 20%
.022uF ± 20%
.047uF ± 20%
60-BPF-030-3-2
0.35mA
250VAC
2200pF ± 20%
.022uF ± 20%
.047uF ± 20%
3A
60-BPF-030-5-2
0.50mA
3300pF ± 20%
60-BPF-030-5-4
.022uF ± 20%
.047uF ± 20%
60-BPF-060-3-2
60-BPF-060-3-4
6.0mH
.022uF ± 20%
.047uF ± 20%
2A
60-BPF-020-5-2
60-BPF-030-3-4
Temperature
Rise (Max.)
.047uF ± 20%
60-BPF-020-3-2
60-BPF-020-3-4
Inductance
(L1)
.022uF ± 20%
.047uF ± 20%
1A
60-BPF-010-5-2
CX
0.35mA
250VAC
2200pF ± 20%
.047uF ± 20%
6A
60-BPF-060-5-2
60-BPF-060-5-4
.022uF ± 20%
0.50mA
3300pF ± 20%
.022uF ± 20%
.047uF ± 20%
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 50g
Input: Compatible with IEC-320
26
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Entry Modules
Bolt-in Right Angle Terminals
60-BPF Series
(
)
1.463 (37.2)
1.967 (50)
Temperature Characteristics
120
1.317
(33.5)
1.573 (40)
.885
(22.5)
.991
(25.2)
.590 (15)
2- .142
(3.6)
Current (%)
100
.047 (1.2)
.232 (5.9)
80
.024
(.6)
5
.
R4
.865
(22)
60
2- .142
(3.6)
1.573 (40)
40
.142
.059 (3.6)
(1.5)
.031 (.8)
1.070
(27.2)
1.180 (30)
* General
tolerance
± .012 (.3)
.779 1.180
(19.8) (30)
.708
(18)
Panel cutout dimensions
mounts from backside
20
0
20
30
40
50
60
70
Ambient Temperature (°C)
80
Power Entry Modules
60-BPF
Fast-on
Terminals
90
Dimensions in inches (mm)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
60-BPF-010;-020
80
70
70
Insertion Loss (dB)
Insertion Loss (dB)
60-BPF-010-3-X
60
50
60-BPF-020-3-X
40
30
20
10
60
60-BPF-010-X-4
50
40
30
60-BPF-020-X-4
20
10
0.2
0.5
1
2
5
10
20
0
0.1
50
0.2
0.5
1
Frequency (MHz)
5
10
20
50
20
50
60-BPF-030;-060
60-BPF-030;-060
80
70
70
60
Insertion Loss (dB)
Insertion Loss (dB)
2
Frequency (MHz)
80
60-BPF-030-3-X
50
40
60-BPF-060-3-X
30
20
60
50
40
60-BPF-030-X-4
30
60-BPF-060-X-4
20
10
10
0
0.1
50Ω
Level
Meter
50Ω
60-BPF-010;-020
80
0
0.1
50Ω
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
27
Power Entry Modules
High Frequency Attenuation
60-BHS Series
Features
Power Entry Modules
■
■
■
■
■
■
■
■
Tested and found to be
IAW VDE 0565 Part 3.
Ideally suited for products that must
conform to FCC part 15 regulations
Metal cased miniature filter offers high performance
Meets over voltage of IEC 664 category II
and complies with IEC 950
PCB mounting types available (see page 56)
PCB mounting minimizes space and provides
economical installation
Excellent filtering characteristics for high frequencies
Earth coil standard
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 29)
Applications
■
■
■
■
Circuit Diagram
3
1
CY
L1
CX
E
E
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
CY
2
4
L2
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
60-BHS-010-3-11
60-BHS-010-3-4
250VAC
Leakage Current
(Max.)
CY
Capacitance
0.35mA
2200pF ± 20%
0.50mA
3300pF ± 20%
60-BHS-010-5-4
0.35mA
250VAC
2200pF ± 20%
0.50mA
3300pF ± 20%
60-BHS-020-5-4
18.3uH
30°C
2.4mH
18.3uH
30°C
1.2mH
18.3uH
30°C
.53mH
18.3uH
45°C
0.1uF ± 20%
0.1uF ± 20%
.047uF ± 20%
60-BHS-030-3-11
0.35mA
250VAC
2200pF ± 20%
0.1uF ± 20%
.047uF ± 20%
3A
60-BHS-030-5-11
0.50mA
3300pF ± 20%
60-BHS-030-5-4
0.1uF ± 20%
.047uF ± 20%
60-BHS-060-3-11
60-BHS-060-3-4
6mH
0.1uF ± 20%
.047uF ± 20%
2A
60-BHS-020-5-11
60-BHS-030-3-4
Temperature
Rise (Max.)
.047uF ± 20%
60-BHS-020-3-11
60-BHS-020-3-4
Inductance
(L1)
(L2)
0.1uF ± 20%
.047uF ± 20%
1A
60-BHS-010-5-11
CX
0.35mA
250VAC
2200pF ± 20%
6A
60-BHS-060-5-11
60-BHS-060-5-4
0.1uF ± 20%
.047uF ± 20%
0.50mA
3300pF ± 20%
0.1uF ± 20%
.047uF ± 20%
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 50g
Input: Compatible with IEC-320
28
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Entry Modules
High Frequency Attenuation
60-BHS Series
.098
(2.5)
1.967 (50)
1.573 (40)
120
.885
(22.5)
100
Current (%)
1.534 (39)
1.389
(35.3)
Power Entry Modules
Temperature Characteristics
1.180
(30)
2- .142
(3.6)
80
1.180 (30)
.031 (.8)
.5
R4
.865
(22)
60
40
2- .142
(3.6)
1.573 (40)
.779 1.180
(19.8) (30)
Panel cutout dimensions
mounts from backside
20
0
20
30
40
50
60
70
Ambient Temperature (°C)
80
Dimensions in inches (mm)
90
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
90
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
60-BHS-XXX-X-11
90
50Ω
50Ω
Level
Meter
50Ω
60-BHS-XXX-3-11
80
80
Insertion Loss (dB)
Insertion Loss (dB)
60-BHS-010-X-11
70
60-BHS-020-X-11
60
50
40
60-BHS-030-X-11
30
60-BHS-060-X-11
70
60-BHS-010-3-11
60
50
60-BHS-020-3-11
40
60-BHS-030-3-11
30
60-BHS-060-3-11
20
20
10
10
0
0.1
0.2
0.5
1
2
5
10
20
0
0.1
50
0.2
0.5
1
90
60-BHS-XXX-X-4
90
5
10
20
50
60-BHS-XXX-3-4
80
60-BHS-010-X-4
70
Insertion Loss (dB)
Insertion Loss (dB)
80
60-BHS-020-X-4
60
50
40
60-BHS-030-X-4
30
60-BHS-060-X-4
70
60-BHS-010-3-4
60
50
60-BHS-020-3-4
40
60-BHS-030-3-4
30
60-BHS-060-3-4
20
20
10
10
0
0.1
2
Frequency (MHz)
Frequency (MHz)
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
29
Power Entry Modules
Bolt-in Rear Terminals
For General Purpose Applications
10-BPF Series
Features
Power Entry Modules
■
■
■
■
■
■
Ideally suited for products that must
conform to FCC part 15 regulations
Metal case offers high performance
Meets over voltage of IEC 664 category II
and complies with IEC 950
Uses IEC connector that meets most safety standards
Operating temperature: -25°C to +70°C
Compact configuration
Circuit Diagram
CX
CY
Applications
■
■
■
■
CY
L1
1
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
CX
CY
L1
CX
CY
2
CX
CX
L1
CY
CY
3
Specifications
Model
Rated
Rated
Voltage
Current
(@ 50/60Hz)
10-BPF-001-5-A
Leakage
Current
(Max.)
1A
120/250VAC
1.5mH
0.50mA
10-BPF-006-5-A
6A
4700pF
10A
10-BPF-010-5-D
Temperature
Rise
(Max.)
C
A
C
2
B
A
0.5mH
1
3300pF & 0.01uF
1.5mH
2
B
3300pF
0.01uF
0.5mH
1
A
3300pF & 0.01uF
3300pF & 0.01uF
1.5mH
3
B
3300pF
3300pF & 0.01uF
10-BPF-006-5-D
0.01uF
Figure
A
3.0mH
1
3A
10-BPF-003-5-C
10-BPF-010-5-A
Inductance Circuit
(L1)
Diagram
3300pF
10-BPF-003-5-A
10-BPF-006-5-C
CX
2200pF
10-BPF-001-5-C
10-BPF-003-5-D
Capacitance
CY
30°C
C
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 45g
Input: Compatible with IEC-320
30
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Entry Modules
Bolt-in Rear Terminals
Figure B
M3 (2X)
For General Purpose Applications
1.6
(40)
M3 (2X)
2.0 (52)
2.0 (52)
1.1 (28.5)
+.01 -0.0
1.6 (40)
±.007
1.4 (37)
2.8 (72)
1.25 (32)
Figure A
Figure C
.80 (20.5)
+.01 -0.0
1.4 (3.5) (2X)
2.3 (62)
1.9 1.6 1.2
(50) (40) (30)
.62 (16)
.82 (21)
.25
(6.5)
1.8 (46)
.13 (3.5 (2X)
1.1 (28)
1.5 (37.5)
1.6 (40)
2.0 (51)
1.9 (50)
1.1 (27)
Power Entry Modules
10-BPF Series
.07 (2)
Dimensions in inches (mm)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
80
70
70
Insertion Loss (dB)
Insertion Loss (dB)
10-BPF-001-5-A
10-BPF-001-5-C
50
40
10-BPF-003-5-A
30
10-BPF-003-5-C
20
60
10-BPF-001-5-A
50
10-BPF-001-5-C
40
30
10-BPF-003-5-A
20
10-BPF-003-5-C
10
10
0
0.1
0.2
0.5
1
2
5
10
20
0
0.1
50
0.2
0.5
1
5
10
50
80
10-BPF-006-5-D
70
70
Insertion Loss (dB)
60
10-BPF-006-5-A
10-BPF-006-5-C
40
30
20
10-BPF-006-5-D
60
50
40
10-BPF-010-5-A
10-BPF-010-5-D
30
10-BPF-006-5-A
20
10-BPF-006-5-C
10-BPF-010-5-A
10
10
0
0.1
20
10-BPF-006;-010
10-BPF-006;-010
80
Insertion Loss (dB)
2
Frequency (MHz)
Frequency (MHz)
50
50Ω
Level
Meter
50Ω
10-BPF-001;-003
10-BPF-001;-003
80
60
50Ω
10-BPF-010-5-D
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
31
Power Entry Modules
Bolt-in Rear Terminals
For Medical Purpose Applications
10-BPF Series
Features
Power Entry Modules
■
■
■
■
■
■
■
Ideally suited for products that must
conform to FCC part 15 regulations
Metal case offers high performance
Meets over voltage of IEC 664 category II
and complies with IEC 950
Uses IEC connector that meets most safety standards
Operating temperature: -25°C to +70°C
Compact configuration
Low leakage current
Circuit Diagram
■
■
■
■
3
1
Applications
L1
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
CX
E
E
2
4
Specifications
Model
Rated
Rated
Voltage
Current
(@ 50/60Hz)
10-BPF-001-2-A
10-BPF-003-2-A 120/250VAC
10-BPF-006-2-A
1A
Leakage
Current
(Max.)
Capacitance
CX
5uA
0.01uF
Inductance
(L1)
Circuit
Diagram
Figure
Temperature
Rise
(Max.)
1
A
30°C
3.0mH
10A
1.5mH
0.5mH
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 45g
Input: Compatible with IEC-320
32
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Entry Modules
Bolt-in Rear Terminals
For Medical Purpose Applications
Power Entry Modules
10-BPF Series
M3 (2X)
1.1 (28.5)
+.01 -0.0
1.6 (40)
±.007
.80 (20.5)
+.01 -0.0
1.4 (3.5)
(2X)
0.807
(20.5)
1.9 1.6 1.2
(50) (40) (30)
Dimensions in inches (mm)
1.1 (28)
1.5 (37.5)
.63 (16)
Common Mode
Normal Mode
1
3
Filter
2
4
1
3
Filter
2
4
Oscillator
50Ω
50Ω
Level
Meter
50Ω
Oscillator
50Ω
50Ω
50Ω
Level
Meter
50Ω
10-BPF-001;-003;-006
80
70
70
Insertion Loss (dB)
Insertion Loss (dB)
10-BPF-001;-003;-006
80
60
2.0 (51)
.25
(6.5)
.82 (21)
10-BPF-001-2-A
50
10-BPF-003-2-A
40
30
20
60
50
40
30
10-BPF-006-2-A
10-BPF-001-2-A
20
10-BPF-006-2-A
10
0
0.1
10
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
10-BPF-003-2-A
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
33
Power Entry Modules
Snap-in with Wire Leads
60-SPL Series
Features
Power Entry Modules
■
■
■
■
■
■
■
Tested and found to be
IAW VDE 0565 Part 3.
Ideally suited for products that must
conform to FCC part 15 regulations
Metal cased miniature filter offers high performance
Meets over voltage of IEC 664 category II
and complies with IEC 950
Uses IEC connector that meets most safety standards
Snap-in style saves labor and hardware inventory
Wire output minimizes space and provides
economical installation
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 35)
Applications
■
■
■
■
Circuit Diagram
3
1
CY
L1
CX
E
E
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
CY
2
4
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
60-SPL-010-3-2
60-SPL-010-3-3
250VAC
Leakage Current
(Max.)
CY
Capacitance
0.35mA
2200pF ± 20%
0.50mA
3300pF ± 20%
60-SPL-010-5-3
0.35mA
250VAC
2200pF ± 20%
0.50mA
3300pF ± 20%
60-SPL-020-5-3
30°C
2.4mH
30°C
1.2mH
30°C
0.53mH
45°C
22nF ± 20%
22nF ± 20%
33nF ± 20%
60-SPL-030-3-2
0.35mA
250VAC
2200pF ± 20%
.022uF ± 20%
3300pF ± 20%
3A
60-SPL-030-5-2
0.50mA
60-SPL-030-5-3
2200pF ± 20%
.033uF ± 20%
3300pF ± 20%
60-SPL-060-3-2
60-SPL-060-3-3
6.0mH
22nF ± 20%
33nF ± 20%
2A
60-SPL-020-5-2
60-SPL-030-3-3
Temperature
Rise (Max.)
33nF ± 20%
60-SPL-020-3-2
60-SPL-020-3-3
Inductance
(L1)
22nF ± 20%
33nF ± 20%
1A
60-SPL-010-5-2
CX
0.35mA
250VAC
2200pF ± 20%
6A
60-SPL-060-5-2
60-SPL-060-5-3
22nF ± 20%
33nF ± 20%
0.50mA
3300pF ± 20%
22nF ± 20%
33nF ± 20%
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 50g
Input: Compatible with IEC-320
34
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Entry Modules
Snap-in with Wire Leads
60-SPL Series
.963
(24.5)
* General tolerance
± .012 (.3)
120
.853
(21.7)
.838 (21.3)
Panel cutout dimensions
100
Current (%)
R2
* Metal case
Tin Plated
80
W
T
W
.039 (1.0)
1.270 (32.3)
.047 (1.2)
1.274 (32.4)
.059 (1.5)
1.285 (32.5)
T :Panel Thickness
1.612 (41)
4.719 (120)*
.252 (6.4)
1.172 (29.8)
.236 (6)
60
Blue
UL 1015 AWG #18
1.397
(35.5)
40
Green/Yellow
Brown
20
PVC Insulated wire
* Custom lengths available upon request.
0
20
30
40
50
60
70
Ambient Temperature (°C)
80
Dimensions in inches (mm)
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
60-SPL-010-X-4
60-SPL-020-5-X
70
60-SPL-010-X-2
Insertion Loss (dB)
60-SPL-010-5-X
50
60-SPL-010-3-X
40
30
20
60
50
60-SPL-020-X-4
40
30
60-SPL-020-X-2
20
10
10
0
0.1
0.2
0.5
1
2
5
10
20
0
0.1
50
0.2
0.5
1
5
10
20
50
60-SPL-030;-060
60-SPL-030;-060
80
80
60-SPL-030-X-4
60-SPL-030-5-X
70
70
60-SPL-030-3-X
Insertion Loss (dB)
60
50
40
60-SPL-060-5-X
30
60-SPL-060-3-X
60
60-SPL-030-X-2
50
40
60-SPL-060-X-4
30
20
20
10
10
0
0.1
2
Frequency (MHz)
Frequency (MHz)
Insertion Loss (dB)
50Ω
Level
Meter
50Ω
80
60-SPL-020-3-X
Insertion Loss (dB)
50Ω
60-SPL-010;-020
60-SPL-010;-020
80
70
UL1617 AWG #22
90
Common Mode
60
Power Entry Modules
Temperature Characteristics
60-SPL-060-X-2
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
35
Power Entry Modules
Bolt-in with Wire Leads
60-BPL Series
Features
Ideally suited for products that must
conform to FCC part 15 regulations
Metal case filter offers high performance
Meets over voltage of IEC 664 category II
and complies with IEC 950
Uses IEC connector that meets most safety standards
Wire output for minimizing space use
and economical installation
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 37)
■
Power Entry Modules
Tested and found to be
IAW VDE 0565 Part 3.
■
■
■
■
■
Circuit Diagram
3
1
Applications
■
■
■
■
CY
L1
CX
E
E
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
CY
2
4
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
60-BPL-010-3-2
60-BPL-010-3-3
250VAC
Leakage Current
(Max.)
CY
Capacitance
0.35mA
2200pF ± 20%
0.50mA
3300pF ± 20%
60-BPL-010-5-3
0.35mA
250VAC
2200pF ± 20%
0.50mA
3300pF ± 20%
60-BPL-020-5-3
30°C
2.4mH
30°C
1.2mH
30°C
0.53mH
45°C
22nF ± 20%
22nF ± 20%
33nF ± 20%
60-BPL-030-3-2
0.35mA
250VAC
2200pF ± 20%
.022uF ± 20%
3300pF ± 20%
3A
60-BPL-030-5-2
0.50mA
60-BPL-030-5-3
2200pF ± 20%
.033uF ± 20%
3300pF ± 20%
60-BPL-060-3-2
60-BPL-060-3-3
6.0mH
22nF ± 20%
33nF ± 20%
2A
60-BPL-020-5-2
60-BPL-030-3-3
Temperature
Rise (Max.)
33nF ± 20%
60-BPL-020-3-2
60-BPL-020-3-3
Inductance
(L1)
22nF ± 20%
33nF ± 20%
1A
60-BPL-010-5-2
CX
0.35mA
250VAC
2200pF ± 20%
33nF ± 20%
6A
60-BPL-060-5-2
60-BPL-060-5-3
22nF ± 20%
0.50mA
3300pF ± 20%
22nF ± 20%
33nF ± 20%
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 50g
Input: Compatible with IEC-320
36
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Entry Modules
Bolt-in with Wire Leads
60-BPL Series
.5
.5
R4
.865
(22)
120
1.180 (30)
1.573 (40)
Current (%)
100
1.573 (40)
1.612 (41)
.830
(21.1)
1.172
(29.8)
1.967
(50)
20
30
40
50
60
70
Ambient Temperature (°C)
80
GREEN/YELLOW
BROWN
90
Dimensions in inches (mm)
Normal Mode
1
3
Filter
2
4
1
3
Filter
2
4
Oscillator
50Ω
50Ω
Level
Meter
50Ω
Oscillator
50Ω
50Ω
50Ω
Level
Meter
50Ω
60-BPL-010;-020
60-BPL-010;-020
80
80
60-BPL-020-5-X
60-BPL-010-X-4
70
70
60-BPL-010-X-2
60
50
60-BPL-010-5-X
40
60-BPL-010-3-X
30
20
Insertion Loss (dB)
60-BPL-020-3-X
60
50
60-BPL-020-X-4
40
30
60-BPL-020-X-2
20
10
10
0.2
0.5
1
2
5
10
20
0
0.1
50
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
Frequency (MHz)
60-BPL-030;-060
60-BPL-030;-060
80
80
60-BPL-030-X-4
60-BPL-030-5-X
70
70
60-BPL-030-3-X
Insertion Loss (dB)
60
50
40
60-BPL-060-5-X
30
60-BPL-060-3-X
20
60
60-BPL-030-X-2
50
40
60-BPL-060-X-2
30
20
60-BPL-060-X-4
10
10
0
0.1
* General tolerance
±.012 (0.3)
PVC Insulated wire
UL1617 AWG #22
* Custom lengths available upon request.
Common Mode
0
0.1
.236 (6)
UL1015 AWG # 18
BLUE
1.160
(29.5)
1.573
(40)
0
Insertion Loss (dB)
4.719 (120)*
.252 (6.4)
60
40
1.239 (31.5)
Panel cutout dimensions
mounts from front side
.944 (24)
2- .142
(3.6)
20
Insertion Loss (dB)
2- .118 (M3)
2- .130 (3.3)
Panel cutout dimensions
mounts from back side
80
R3
.885
(22.5)
.837
(21.3)
Power Entry Modules
Temperature Characteristics
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
37
Power Entry Modules
Bolt-in with Wire Leads
10-BPL Series
Features
Ideally suited for products that must
conform to FCC part 15 regulations
Metal case filter offers high performance
Meets over voltage of IEC 664 category II
and complies with IEC 950
Uses IEC connector that meets most safety standards
Wire output for minimizing space use
and economical installation
Operating temperature: -25°C to +70°C
Compact configuration
Power Entry Modules
■
■
■
■
■
■
■
Circuit Diagram
Applications
■
■
■
■
3
1
CY
L1
CX
E
E
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
CY
2
4
Specifications
Model
Rated
Rated Leakage
Voltage
Current Current
(@ 50/60Hz)
(Max.)
10-BPL-006-5-B
CX
3300pF
0.01uF
1A
10-BPL-001-5-B
10-BPL-003-5-B
Capacitance
CY
250VAC
3A
Inductance Circuit
Diagram
(L1)
Figure
Temperature
Rise
(Max.)
A
30°C
3.0mH
0.50mA
6A
1.5mH
1
0.5mH
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 50g
Input: Compatible with IEC-320
38
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Entry Modules
Bolt-in with Wire Leads
10-BPL Series
Figure A
Power Entry Modules
M3 (2X)
1.1 (28.5)
+.01 -0.0
1.6 (40)
±.007
.80 (20.5)
+.01 -0.0
1.4 (3.5)
(2X)
1.9 1.6 1.2
(50) (40) (30)
1.1 (28)
1.5 (37.5)
.63 (16)
2.0 (51)
.25
(6.5)
.82 (21)
Dimensions in inches (mm)
Common Mode
Normal Mode
1
3
Filter
2
4
1
3
Filter
2
4
Oscillator
50Ω
50Ω
Level
Meter
50Ω
Oscillator
50Ω
80
10-BPL-001-5-B
70
70
10-BPL-003-5-B
10-BPL-001-5-B
Insertion Loss (dB)
Insertion Loss (dB)
50Ω
Level
Meter
50Ω
10-BPL-001;-003;-006
10-BPL-001;-003;-006
80
60
50Ω
50
40
30
10-BPL-006-5-B
20
60
50
40
10-BPL-003-5-B
30
20
10-BPL-006-5-B
10
10
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
39
Power Entry Modules
Snap-in Mount
60-SPR & SPS Series
Features
Power Entry Modules
■
■
■
■
■
■
■
■
Tested and found to be
IAW VDE 0565 Part 3.
Ideally suited for products that must
conform to FCC part 15 regulations
Metal cased miniature filter offers high performance
Meets over voltage of IEC 664 category II
and complies with IEC 950
Uses IEC connector that meets most safety standards
Snap-in style saves labor and hardware inventory
Solder lug and fast-on tab terminations available
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 41)
UL approved low leakage version also available
■
■
■
3
1
CY
L1
CX
Applications
■
Circuit Diagram
E
E
CY
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
2
4
Specifications
Model*
Rated Voltage
(@ 50/60Hz)
Rated
Current
60-XXX-010-3-2
60-XXX-010-3-4
250VAC
Leakage Current
(Max.)
CY
Capacitance
0.35mA
2200pF ± 20%
0.50mA
3300pF ± 20%
60-XXX-010-5-4
0.35mA
250VAC
2200pF ± 20%
30°C
2.4mH
30°C
1.2mH
30°C
0.53mH
45°C
.022uF ± 20%
0.26mH
45°C
.01uF ± 20%
0.15mH
45°C
.022uF ± 20%
.022uF ± 20%
.047uF ± 20%
2A
60-XXX-020-5-2
0.50mA
3300pF ± 20%
60-XXX-020-5-4
.022uF ± 20%
.047uF ± 20%
60-XXX-030-3-2
60-XXX-030-3-4
6.0mH
.022uF ± 20%
.047uF ± 20%
60-XXX-020-3-2
60-XXX-020-3-4
Temperature
Rise (Max.)
.047uF ± 20%
1A
60-XXX-010-5-2
Inductance
(L1)
CX
0.35mA
250VAC
.022uF ± 20%
2200pF ± 20%
.047uF ± 20%
3A
60-XXX-030-5-2
0.50mA
.022uF ± 20%
3300pF ± 20%
60-XXX-030-5-4
.047uF ± 20%
60-XXX-060-3-2
60-XXX-060-3-4
0.35mA
250VAC
2200pF ± 20%
.047uF ± 20%
6A
60-XXX-060-5-2
0.50mA
3300pF ± 20%
0.35mA
2200pF ± 20%
0.50mA
3300pF ± 20%
0.35mA
2200pF ± 20%
60-XXX-060-5-4
60-XXX-100-3-2
250VAC
10A
250VAC
15A
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 45g
Input: Compatible with IEC-320
40
.022uF ± 20%
.047uF ± 20%
60-XXX-100-5-2
60-SPR-150-3-11
.022uF ± 20%
* Substitute SPR or SPS for XXX
60-SPR - Fast-on terminals
60-SPS - Solder lug terminals
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Entry Modules
Snap-in Mount
60-SPR & SPS Series
.837
(21.3)
.963
(24.5)
120
.853
(21.7)
Panel cutout dimensions
Current (%)
100
80
T: Panel Thickness
T
W
.039 (1.0)
1.270 (32.3)
.047 (1.2)
1.274 (32.4)
.059 (1.5)
1.285 (32.5)
1.418 (35.9)
.157
(4)
1.395
(35.5)
* Standard terminal
Fast-on tab #250
available as
SPR series
2.096 (53.3)
20
30
40
50
60
70
Ambient Temperature (°C)
80
90
Solder lugs shown. Also available in fast-ons.
Common Mode
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
60-SPX-010;-020;-030
50Ω
50Ω
Level
Meter
50Ω
60-SPX-010;-020;-030
80
80
70
70
60-SPX-010-5-X
60-SPX-010-X-4
Insertion Loss (dB)
60
50
40
60-SPX-020-5-X
30
60-SPX-030-5-X
20
10
60
50
60-SPX-020-X-4
40
60-SPX-030-X-4
30
20
10
0.2
0.5
1
2
5
10
20
0
0.1
50
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
Frequency (MHz)
60-SPX-060;-100
60-SPX-060;-100
80
80
70
70
Insertion Loss (dB)
60
60-SPX-60-5-X
50
40
30
60-SPX-100-5-X
20
10
0
0.1
Dimensions in inches (mm)
Normal Mode
1
3
Filter
2
4
0
0.1
1.172
(29.8)
* General tolerance
± .012 (0.3)
0
Insertion Loss (dB)
Solder Lug
2 X 3 hole
40
20
Insertion Loss (dB)
1.805 (45.9)
.252 (6.4)
60
W
Panel cutout dimensions
for 1.0t chassis
2.033 (51.7)
Power Entry Modules
R2
Temperature Characteristics
60-SPX-060-X-4
60
50
60-SPX-060-X-2
40
60-SPX-100-X-2
30
20
10
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
41
Fused Filtered
Power Entry Modules
For General Purpose Applications
64-65-BFF/64-65-BFS Series
Features
Fused Filtered
Power Entry Modules
■
■
■
■
■
■
■
Tested and found to be
IAW VDE 0565 Part 3.
North American and Metric fuse
holders available
Fuse holder provides effective EMI suppression
of common and differential mode
Suitable for products that must conform
to FCC and FTZ requirements
Meets over voltage category II of IEC 664
and complies with IEC 950
Fast-on terminals or solder lug terminals
Metal case provides effective EMI shielding
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 43)
■
■
■
■
L
L
L1
E
R
CY
E
CX
CY
Applications
■
Circuit Diagram
N
N
Computers and peripheral equipment
Electronic equipment
Digital equipment
Measuring and testing instruments
Telecommunications equipment
Specifications
Model*
64-XXX-020-3-11
64-XXX-020-5-11
64-XXX-020-3-12
64-XXX-020-5-12
64-XXX-040-3-11
64-XXX-040-5-11
64-XXX-040-3-12
64-XXX-040-5-12
64-XXX-060-3-11
64-XXX-060-5-11
64-XXX-060-3-12
64-XXX-060-5-12
65-XXX-020-3-11
65-XXX-020-5-11
65-XXX-020-3-12
65-XXX-020-5-12
65-XXX-040-3-11
65-XXX-040-5-11
65-XXX-040-3-12
65-XXX-040-5-12
65-XXX-060-3-11
65-XXX-060-5-11
65-XXX-060-3-12
65-XXX-060-5-12
Rated Voltage
(@ 50/60Hz)
250VAC
250VAC
250VAC
125VAC
125VAC
125VAC
Rated
Current
2A
4A
6A
2A
4A
6A
Note: Test Voltage 1500VAC one minute, line to ground
Insulation Resistance: 300 MΩ min. at 500VDC
F(S) = Fast-on or (Solder lug terminals)
42
Leakage Current
(Max.)
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.20mA
0.25mA
0.20mA
0.25mA
0.20mA
0.25mA
0.20mA
0.25mA
0.20mA
0.25mA
0.20mA
0.25mA
Capacitance
CY
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
CX
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
Voltage Drop: 1V max. at rated current
Weight: 78g
Inlet: Compatible with IEC-320
Inductance
(L1)
Temperature
Rise (Max.)
6.5mH
40°C
4.2mH
45°C
1.6mH
45°C
6.5mH
40°C
4.2mH
45°C
1.6mH
45°C
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
* Substitute BFF or BFS for XXX
BFF - Fast-on terminals
BFS - Solder lug terminals
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Fused Filtered
Power Entry Modules
For General Purpose Applications
64-65-BFF/64-65-BFS Series
Dimensions
Temperature Characteristics
1.738 (44.2)
100
Current (%)
2.32 (59)
.098 (2.5)
1.101 (28)
Fuse cover
1.376
(35)
80
1.298
(33)
1.29
(32.8)
2 - .13 +.008
-.004
(2 - 3.3+0.2
-0.1)
Hole
60
1.416±.008
(36±0.2)
0.252 (6.4)
1.14
(29)
1.616 (41.1)
* Alternate Terminal for 64/65-BFS-Solder Lug Terminal
40
Fast-on tab#250
t= .031 (0.8)
20
0.158
(4.0)
0
20
30
40
50
60
70
Ambient Temperature (°C)
80
Fused Filtered
Power Entry Modules
64/65-BFF Series
120
* General Tolerance:
±.020 (0.5)
* Metal Case
90
2.249 (L:57.2)
Dimensions in inches (mm)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
0.50 mA Leakage Versions
50Ω
50Ω
Level
Meter
50Ω
0.50 mA Leakage Versions
90
90
80
80
2 Amp
70
2 Amp
Insertion Loss (dB)
Insertion Loss (dB)
70
60
50
40
6 Amp
30
20
60
50
6 Amp
40
4 Amp
30
20
4 Amp
10
10
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
10
20
0
0.1
50
0.35 mA Leakage Versions
90
90
80
80
2 Amp
Insertion Loss (dB)
Insertion Loss (dB)
0.5
1
2
5
Frequency (MHz)
10
20
50
10
20
50
0.35 mA Leakage Versions
70
70
60
50
40
6 Amp
30
2 Amp
60
50
40
6 Amp
30
4 Amp
20
20
4 Amp
10
10
0
0.1
0.2
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
43
Fused Filtered
Power Entry Modules
For Medical or General Purpose Applications
■
■
■
■
■
■
■
■
■
■
Medical equipment
Electronic equipment
Digital equipment
Industrial equipment
■
■
■
Telecommunications equipment
Measuring and testing instruments
Personal computers
and peripherals
Circuit Diagrams
66/67-BFF(S)-XXX-0-X and
66/67-BFF(S)-XXX-4-X Filters
66/67-BFF(S)-XXX-1-X Filter
L
L
L
L
L1
R
L1
CX
E
E
R
CY
CX
E
E
CY
N
N
N
N
Specifications
Model*
66-XXX-020-1-11
66-XXX-020-1-12
66-XXX-020-0-11
66-XXX-020-4-11
66-XXX-020-0-12
66-XXX-020-4-12
66-XXX-040-1-11
66-XXX-040-1-12
66-XXX-040-0-11
66-XXX-040-4-11
66-XXX-040-0-12
66-XXX-040-4-12
66-XXX-060-1-11
66-XXX-060-1-12
66-XXX-060-0-11
66-XXX-060-4-11
66-XXX-060-0-12
66-XXX-060-4-12
67-XXX-020-1-11
67-XXX-020-1-12
67-XXX-020-0-11
67-XXX-020-4-11
67-XXX-020-0-12
67-XXX-020-4-12
67-XXX-040-1-11
67-XXX-040-1-12
67-XXX-040-0-11
67-XXX-040-4-11
67-XXX-040-0-12
67-XXX-040-4-12
67-XXX-060-1-11
67-XXX-060-1-12
67-XXX-060-0-11
67-XXX-060-4-11
67-XXX-060-0-12
67-XXX-060-4-12
Rated Voltage
(@ 50/60Hz)
Rated
Current
0.01mA
250VAC
2A
0.075mA
0.1mA
0.075mA
0.1mA
0.01mA
250VAC
4A
0.075mA
0.1mA
0.075mA
0.1mA
0.01mA
250VAC
6A
0.075mA
0.1mA
0.075mA
0.1mA
0.005mA
125VAC
2A
0.035mA
0.05mA
0.035mA
0.05mA
0.005mA
125VAC
4A
0.035mA
0.05mA
0.035mA
0.05mA
0.005mA
125VAC
6A
Note: Test Voltage 1500VAC one minute, line to ground
Insulation Resistance: 300 MΩ min. at 500VDC
F(S) = Fast-on or (Solder lug terminals)
44
Leakage Current
(Max.)
0.035mA
0.05mA
0.035mA
0.05mA
Capacitance
CY
none
330pF
470pF
330pF
470pF
±
±
±
±
20%
20%
20%
20%
none
330pF
470pF
330pF
470pF
±
±
±
±
20%
20%
20%
20%
none
330pF
470pF
330pF
470pF
±
±
±
±
20%
20%
20%
20%
none
330pF
470pF
330pF
470pF
±
±
±
±
20%
20%
20%
20%
none
330pF
470pF
330pF
470pF
±
±
±
±
20%
20%
20%
20%
none
330pF
470pF
330pF
470pF
±
±
±
±
20%
20%
20%
20%
Voltage Drop: 1V max. at rated current
Weight: 78g
Inlet: Compatible with IEC-320
CX
0.1uF
0.22uF
0.1uF
Inductance
(L1)
Temperature
Rise (Max.)
6.5mH
40°C
4.2mH
45°C
1.6mH
45°C
6.5mH
40°C
4.2mH
45°C
1.6mH
45°C
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
* Substitute BFF or BFS for XXX
BFF - Fast-on terminals
BFS - Solder lug terminals
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
LOAD
■
Applications
LINE
■
Tested and found to be
IAW VDE 0565 Part 3.
Metric and North American fuse
holders available
Fuse holder provides effective EMI suppression
of common and differential mode
Suitable for products that must conform
to FCC and FTZ requirements
Meets over voltage category II of IEC 664
and complies with IEC 950
Fast-on terminations or solder lug terminations
Metal case provides effective EMI shielding
Provides susceptibility protection without the leakage
current associated with line-to-ground capacitance
Reduces the line to ground capacitance in order
to meet patient care requirements
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 45)
LOAD
Fused Filtered
Power Entry Modules
■
LINE
66-67-BFF/66-67-BFS Series
Features
Fused Filtered
Power Entry Modules
For Medical or General Purpose Applications
66-67-BFF/66-67-BFS Series
Dimensions
Temperature Characteristics
1.738 (44.2)
2.32 (59)
.098 (2.5)
1.101 (28)
100
Current (%)
Fuse cover
1.376
(35)
80
1.298
(33)
60
1.416±.008
(36±0.2)
40
1.29
(32.8)
2 - .13 +.008
-.004
(2 - 3.3+0.2
-0.1)
Hole
0.252 (6.4)
1.14
(29)
1.616 (41.1)
* Alternate Terminal for 66/67-BFS-Solder Lug Terminal
Fast-on tab#250
t= .031 (0.8)
20
0.158
(4.0)
0
20
30
40
50
60
70
Ambient Temperature (°C)
80
2.249 (L:57.2)
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
90
90
80
80
70
70
Insertion Loss (dB)
Insertion Loss (dB)
50Ω
60
2 Amp
40
30
60
2 Amp
50
30
0
0.1
0.2
0.5
10
1
2
5
Frequency (MHz)
10
20
0
0.1
50
80
80
70
70
Insertion Loss (dB)
90
60
2 Amp
50
0.2
0.5
1
2
5
Frequency (MHz)
40
30
10
0.2
0.5
20
50
60
50
2 Amp
40
30
4 Amp
20
20
6 Amp
6 Amp
4 Amp
10
0.075 and 0.1 mA Leakage Current
0.075 and 0.1 mA Leakage Current
90
0
0.1
6 Amp
6 Amp
4 Amp
4 Amp
40
20
20
10
50Ω
Level
Meter
50Ω
0.01 mA Leakage Current
0.01 mA Leakage Current
Insertion Loss (dB)
Dimensions in inches (mm)
Normal Mode
1
3
Filter
2
4
50
* General Tolerance:
±.020 (0.5)
* Metal Case
90
Common Mode
Fused Filtered
Power Entry Modules
66-67-BFF/66-67-BFS Series
120
10
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
45
Switched and Fused Filtered
Power Entry Modules
Switched and Fused Filtered
Power Entry Modules
For General Purpose Applications
64-65-BSF/64-65-SSF Series
Features
■
■
■
■
■
■
■
■
Tested and found to be
IAW VDE 0565 Part 3.
North American and Metric fuse
holders available
Fuse holder and double pole power ON/OFF switch
provided in a convenient/compact package
Suitable for products that must conform
to FCC and FTZ requirements
Meets over voltage category II of IEC 664
and complies with IEC 950
Metal case provides effective EMI shielding
Easy access fuse drawer with space for spare fuse
Flange-mounted or snap-in styles available
for quick mounting
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 47)
Applications
■
■
Computers and
peripheral equipment
Electronic equipment
■
■
■
Digital equipment
Measuring and testing instruments
Telecommunications equipment
Circuit Diagram
L
L
CY
CX
E
CX
E
R
CY
N
N
Specifications
Model*
Rated Voltage
(@ 50/60Hz)
Rated
Current
64-XXX-020-3-12
64-XXX-020-3-04
64-XXX-020-3-14
64-XXX-020-3-06
250VAC
2A
64-XXX-020-5-12
64-XXX-020-5-04
64-XXX-020-5-14
64-XXX-020-5-06
64-XXX-040-3-12
64-XXX-040-3-04
64-XXX-040-3-14
64-XXX-040-3-06
250VAC
4A
64-XXX-040-5-12
64-XXX-040-5-04
64-XXX-040-5-14
64-XXX-040-5-06
64-XXX-060-3-12
64-XXX-060-3-04
64-XXX-060-3-14
64-XXX-060-3-06
250VAC
6A
64-XXX-060-5-12
64-XXX-060-5-04
64-XXX-060-5-14
64-XXX-060-5-06
65-XXX-020-3-12
65-XXX-020-3-04
65-XXX-020-3-14
65-XXX-020-3-06
125VAC
2A
65-XXX-020-5-12
65-XXX-020-5-04
65-XXX-020-5-14
65-XXX-020-5-06
65-XXX-040-3-12
65-XXX-040-3-04
65-XXX-040-3-14
65-XXX-040-3-06
125VAC
4A
65-XXX-040-5-12
65-XXX-040-5-04
65-XXX-040-5-14
65-XXX-040-5-06
65-XXX-060-3-12
65-XXX-060-3-04
65-XXX-060-3-14
65-XXX-060-3-06
125VAC
6A
65-XXX-060-5-12
65-XXX-060-5-04
65-XXX-060-5-14
65-XXX-060-5-06
Note: Test Voltage 1500VAC one minute, line to ground
Insulation Resistance: 300 MΩ min. at 500VDC
B(S) = Bolt-in terminals or (Snap-in terminals)
46
Leakage Current
(Max.)
CY
0.35mA
2200pF
Capacitance
CX1
0.22uF
0.47uF
0.22uF
0.50mA
3300pF
0.47uF
0.22uF
0.35mA
2200pF
0.47uF
0.22uF
0.50mA
3300pF
0.47uF
0.22uF
0.35mA
0.47uF
2200pF
0.22uF
0.50mA
0.47uF
0.22uF
0.35mA
2200pF
0.47uF
0.22uF
0.50mA
3300pF
0.47uF
0.22uF
0.35mA
2200pF
0.47uF
0.22uF
0.50mA
3300pF
0.47uF
0.22uF
0.35mA
0.47uF
2200pF
0.22uF
0.50mA
0.47uF
Voltage Drop: 1V max. at rated current
Weight: 130g
Inlet: Compatible with IEC-320
CX2
Inductance
(L1)
NONE
0.22uF
NONE
10.5mH
0.47uF
NONE
0.22uF
NONE
0.47uF
NONE
0.22uF
NONE
0.47uF
4.2mH
NONE
0.22uF
NONE
0.47uF
NONE
0.22uF
NONE
0.47uF
1.6mH
NONE
0.22uF
NONE
0.47uF
NONE
0.22uF
NONE
0.47uF
10.5mH
NONE
0.22uF
NONE
0.47uF
NONE
0.22uF
NONE
0.47uF
4.2mH
NONE
0.22uF
NONE
0.47uF
NONE
0.22uF
NONE
0.47uF
1.6mH
NONE
0.22uF
NONE
0.47uF
* Substitute BSF or SSF for XXX
BSF - Bolt-in switched and fused
SSF - Snap-in switched and fused
Temperature
Rise (Max.)
45°C
45°C
45°C
45°C
45°C
45°C
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Temperature
Temperature Characteristics
Characteristics
120
100
Current (%)
Switched and Fused Filtered
Power Entry Modules
80
60
40
20
0
Dimensions
30
40
50
60
70
Ambient Temperature (°C)
80
90
64/65-SSF Series
64/65-BSF Series
1.947 (49.5)
1.101 (28)
20
1.313 (33.4)
1.101 (28)
.248
(6.3)
.248
(6.3)
1.133
(28.8)
1.514 (38.8)
1.526 (38.8)
Fast-on tab #250
t= .031 (0.8)
2.556
(65)
2.556
(65)
2.340
(59.5)
2.348
(59.7)
2.348
(59.7)
2.340
(59.5)
Ø.142
(3.6)
R .079
(2.0)
2 - .142
(3.6) Hole
R .059
(1.5)
A
t= .031 (0.8)
Panel cutout
dimension
mount from
back side
1.573 1.16±.334
0
(40.±0.2) (29.5± 0.5)
0
Thickness of Panel
.031 (0.8t)
.039 (1.0t)
.047 (1.2t)
.059 (1.5t)
.071 (1.8t)
.079 (2.0t)
1.133
(28.8)
Fast-on Tab #250
2.273 (57.8)
1.573 (40±0.2)
2.273 (57.8)
Dimensions in inches (mm)
Panel cutout dimension
mount from back side
1.16 +.02
-0
(29.5 +0.5
-0 )
A
2.430 (61.8±0.1)
2.446 (62.2±0.1)
2.462 (62.6±0.1)
2.470 (62.8±0.1)
2.473 (62.9±0.1)
2.477 (63.0±0.1)
Switched and Fused Filtered
Power Entry Modules
For General Purpose Applications
* General Tolerance
± .039 (1.0)
* Metal Case
2.399 (61)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
Oscillator
50Ω
0.35 mA Leakage Versions
100
80
90
70
80
2 Amp
Insertion Loss (dB)
Insertion Loss (dB)
50Ω
Level
Meter
50Ω
64/65-B(S)SF-*-*-02(04,06)
90
60
50
40
4 Amp
30
6 Amp
20
70
60
50
2 Amp
40
4 Amp
30
10
6 Amp
20
0
0.1
0.2
1
0.5
2
5
Frequency (MHz)
10
20
0
0.1
50
0.50 mA Leakage Versions
0.5
1
2
5
Frequency (MHz)
10
20
50
20
50
100
80
90
70
80
Insertion Loss (dB)
2 Amp
60
50
40
4 Amp
30
6 Amp
20
70
60
4 Amp
6 Amp
50
2 Amp
40
30
10
0
0.1
0.2
64/65-B(S)SF-*-*-11(12,14)
90
Insertion Loss (dB)
50Ω
20
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
10
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
47
Switched and Fused Filtered
Power Entry Modules
66-67-BSF/66-67-SSF Series
Features
Tested and found to be
IAW VDE 0565 Part 3
Metric and North American fuse holders available
Fuse holder and a double pole power ON/OFF switch
provides a convenient/compact package
■ Suitable for products that must conform
to FCC and FTZ requirements
■ Meets over voltage category II of IEC 664
and complies with IEC 950
■ Provides susceptibility protection without the leakage
current associated with line-to-ground capacitors
■ Designed to meet requirements for non-patient
and patient care equipment
■ Metal case provides effective EMI shielding
■ Easy access fuse drawer - space for spare fuse
■ Flange-mounted or snap-in styles available
for quick mounting
■ Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 49)
■
■
Applications
■
■
■
■
Medical equipment
Industrial equipment
Telecommunications equipment
Measuring and testing instruments
■
■
Digital equipment (including
switching power supplies)
General purpose filter for
susceptibility or high frequency
“clean up” applications
Circuit Diagram
L
L
L1
R
CX1
CX2
CY1
E
E
LOAD
Note: CY1 and CY2 capacitors
omitted on 66/67
B(S)F-XXX-1-X Filters
LINE
Switched and Fused Filtered
Power Entry Modules
For Medical or General Purpose Applications
CY2
N
N
Specifications
Model*
66-XXX-020-0-12
66-XXX-020-0-04
66-XXX-020-0-14
66-XXX-020-0-06
66-XXX-020-1-12
66-XXX-020-1-04
66-XXX-020-1-14
66-XXX-020-1-06
66-XXX-020-4-12
66-XXX-020-4-04
66-XXX-020-4-14
66-XXX-020-4-06
66-XXX-040-0-12
66-XXX-040-0-04
66-XXX-040-0-14
66-XXX-040-0-06
66-XXX-040-1-12
66-XXX-040-1-04
66-XXX-040-1-14
66-XXX-040-1-06
66-XXX-040-4-12
66-XXX-040-4-04
66-XXX-040-4-14
66-XXX-040-4-06
66-XXX-060-0-12
66-XXX-060-0-04
66-XXX-060-0-14
66-XXX-060-0-06
66-XXX-060-1-12
66-XXX-060-1-04
66-XXX-060-1-14
66-XXX-060-1-06
66-XXX-060-4-12
66-XXX-060-4-04
66-XXX-060-4-14
66-XXX-060-4-06
Rated Rated Leakage
Voltage Current Current
Capacitance
50/60Hz
(Max.) CY
CX1
CX2
0.22uF
.075mA 330pF
0.47uF
0.22uF
2A
.01mA NONE
0.47uF
0.22uF
0.1mA 470pF
0.47uF
0.22uF
.075mA 330pF
0.47uF
250
VAC
0.22uF
4A
.01mA NONE
0.47uF
0.22uF
.01mA 470pF
0.47uF
0.22uF
.075mA 330pF
0.47uF
0.22uF
6A
.01mA NONE
0.47uF
0.22uF
0.1mA 470pF
0.47uF
Rise
(Max.)
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF 10.5mH 40°C
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
4.2mH
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
45°C
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
1.6mH
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
Note: Test Voltage: 1500VAC one minute, line to ground
Insulation Resistance: 300 MΩ min. at 500VDC
Voltage Drop: 1V max. at rated current
48
Temp.
Induct.
(L1)
Model*
67-XXX-020-0-12
67-XXX-020-0-04
67-XXX-020-0-14
67-XXX-020-0-06
67-XXX-020-1-12
67-XXX-020-1-04
67-XXX-020-1-14
67-XXX-020-1-06
67-XXX-020-4-12
67-XXX-020-4-04
67-XXX-020-4-14
67-XXX-020-4-06
67-XXX-040-0-12
67-XXX-040-0-04
67-XXX-040-0-14
67-XXX-040-0-06
67-XXX-040-1-12
67-XXX-040-1-04
67-XXX-040-1-14
67-XXX-040-1-06
67-XXX-040-4-12
67-XXX-040-4-04
67-XXX-040-4-14
67-XXX-040-4-06
67-XXX-060-0-12
67-XXX-060-0-04
67-XXX-060-0-14
67-XXX-060-0-06
67-XXX-060-1-12
67-XXX-060-1-04
67-XXX-060-1-14
67-XXX-060-1-06
67-XXX-060-4-12
67-XXX-060-4-04
67-XXX-060-4-14
67-XXX-060-4-06
Rated Rated Leakage
Voltage Current Current
Capacitance
50/60Hz
(Max.) CY
CX1
CX2
0.22uF
0.04mA 330pF
0.47uF
0.22uF
2A
.005mA NONE
0.47uF
0.22uF
0.05mA 470pF
0.47uF
0.22uF
0.04mA 330pF
0.47uF
125
VAC
0.22uF
4A
.005mA NONE
0.47uF
0.22uF
0.05mA 470pF
0.47uF
0.22uF
0.04mA 330pF
0.47uF
0.22uF
6A
Weight: 130g
Inlet: Compatible with IEC-320
B(S) = Bolt-in terminals or (Snap-in terminals)
.005mA NONE
0.47uF
0.22uF
0.05mA 470pF
0.47uF
Temp.
Induct.
(L1)
Rise
(Max.)
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF 10.5mH 40°C
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
4.2mH
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
45°C
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
1.6mH
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
* Substitute BSF or SSF for XXX
BSF - Bolt-In Switched and Fused
SSF - Snap-In Switched and Fused
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Temperature Characteristics
120
100
Current (%)
Switched and Fused Filtered
Power Entry Modules
For Medical or General Purpose Applications
80
60
40
20
20
30
40
50
60
70
Ambient Temperature (°C)
80
90
Dimensions
66/67-BSF Series
1.947 (49.5)
1.101 (28)
66/67-SSF Series
.248
(6.3)
1.313 (33.4)
1.101 (28)
1.526 (38.8)
.248
(6.3)
1.133
(28.8)
1.514 (38.8)
Fast-on tab #250
2.556
(65)
t= .031 (0.8)
2.556
(65)
2.348
(59.7)
2.340
(59.5)
Ø.142
(3.6)
2 - .142
(3.6) Hole
R .079
(2.0)
1.133
(28.8)
Fast-on Tab #250
2.273 (57.8)
1.573 (40±0.2)
2.340
(59.5)
2.348
(59.7)
R .059
(1.5)
A
Dimensions in inches (mm)
2.399 (61)
Common Mode
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
80
80
70
70
Insertion Loss (dB)
Insertion Loss (dB)
90
60
2 Amp
40
30
20
2 Amp
50
40
30
4 Amp
6 Amp
10
10
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
10
20
0
0.1
50
90
80
80
70
70
Insertion Loss (dB)
90
60
2 Amp
50
40
30
20
1
2
5
Frequency (MHz)
10
20
50
2 Amp
60
50
40
4 Amp
30
6 Amp
10
10
0
0.1
0.5
20
6 Amp
4 Amp
0.2
0.075 and 0.1 mA Leakage Current
0.075 and 0.1 mA Leakage Current
Insertion Loss (dB)
50Ω
Level
Meter
50Ω
60
20
6 Amp
4 Amp
50Ω
0.01 mA Leakage Current
0.01 mA Leakage Current
90
50
* General Tolerance
± .039 (1.0)
* Metal Case
Panel cutout dimension
mount from back side
1.16 +.02
-0
(29.5 +0.5
-0 )
A
2.430 (61.8±0.1)
2.446 (62.2±0.1)
2.462 (62.6±0.1)
2.470 (62.8±0.1)
2.473 (62.9±0.1)
2.477 (63.0±0.1)
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
Thickness of Panel
.031 (0.8t)
.039 (1.0t)
.047 (1.2t)
.059 (1.5t)
.071 (1.8t)
.079 (2.0t)
t= .031 (0.8)
Panel cutout
dimension
mount from
back side
1.573
1.16 +.02
-0
(40.±0.2) (29.5 +0.5)
-0
2.273 (57.8)
Switched and Fused Filtered
Power Entry Modules
0
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
49
Switched and Fused Filtered
Power Entry Modules
Switched and Fused Filtered
Power Entry Modules
Dual Fuse for European Applications
68-BSF Series
Features
Dual fuse for European applications
Fuse holder and double pole power ON/OFF switch
provides a convenient/compact package
■ Suitable for products that must conform
to FCC and FTZ requirements
■ Meets over voltage category II of IEC 664
and complies with IEC 950
■ Metal case provides effective EMI shielding
■ IEC connector meets the safety standards of most
certifying agencies
■ Easy access fuse drawer
■ Flange-mounted
■ UL, CSA, and SEMKO approved
■ Designed to be in accordance with VDE 0565, part 3
■ Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 51)
■
■
Circuit Diagram
FUSE
L
L
L1
E
CY1
CX2
CX1
E
R1
L2
CY2
N
N
SW
Applications
Computers and peripheral equipment
Electronic equipment
■ Digital equipment
■ Measuring and testing instruments
■ Telecommunications equipment
■
■
Specifications
Model
Rated Voltage
(@ 50/60Hz)
68-BSF-020-3-01
Rated
Current
Leakage Current
(Max.)
CY1
Capacitance
CY2
CX1
2A
68-BSF-020-3-04
68-BSF-040-3-01
250VAC
4A
68-BSF-040-3-04
68-BSF-060-3-01
6A
68-BSF-060-3-04
0.35mA
2200pF
2200pF
CX2
0.1uF
0.1uF
0.22uF
0.22uF
0.1uF
0.1uF
0.22uF
0.22uF
0.1uF
0.1uF
0.22uF
0.22uF
Inductance
(L1)
Temperature
Rise (Max.)
10.5mH
4.2mH
45°C
1.6mH
Note: Test Voltage 1500VAC one minute, line to ground
Insulation Resistance: 300 MΩ min. at 500VDC
Voltage Drop: 1V max. at rated current
Weight: 130g
Inlet: Compatible with IEC-320
B(S) = Bolt-in terminals or (Snap-in terminals)
50
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Switched and Fused Filtered
Power Entry Modules
Dual Fuse for European Applications
Temperature Characteristics
1.947 (49.5)
1.101 (28)
.248
(6.3)
1.526 (38.8)
120
2.556
(65)
Current (%)
100
80
2.348
(59.7)
60
2 - .142
(3.6) Hole
20
30
40
50
60
70
Ambient Temperature (°C)
80
90
Dimensions in inches (mm)
Normal Mode
1
3
Filter
2
4
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
90
50Ω
50Ω
Level
Meter
50Ω
100
90
70
80
Insertion Loss (dB)
80
60
50
40
4 Amp
30
2 Amp
6 Amp
20
70
4 Amp
60
50
2 Amp
40
30
10
0
0.1
t= .031 (0.8)
2.399 (61)
Common Mode
Oscillator
50Ω
R .059
(1.5)
Panel cutout
dimension
mount from
back side
1.573
1.16 +.02
-0
(40.±0.2) (29.5 +0.5)
-0
0
1.133
(28.8)
Fast-on Tab #250
2.273 (57.8)
1.573 (40±0.2)
40
20
Insertion Loss (dB)
2.340
(59.5)
Ø.142
(3.6)
Switched and Fused Filtered
Power Entry Modules
68-BSF Series
6 Amp
20
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
51
PCB Power Filters
Miniature Printed Circuit Board
61-MPC Series
Tested and found to be
IAW VDE 0565 Part 3
Features
■
■
■
■
■
PCB Power Filters
■
Miniature general purpose PCB mounted filter
Requires minimal PCB real estate space
Low cost
Designed for two wire cord systems
For three wire cord systems, Y capacitors
can be attached externally
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 53)
Circuit Diagram
3
1
Applications
■
■
■
■
■
L1
Personal computers and peripherals
Digital equipment
Measuring instruments and medical equipment
TV & VCR monitors and display units
Home appliances
CX1
CX1
2
4
Specifications
Model
Rated Voltage
(@ 50/60Hz)
61-MPC-010-1-11
61-MPC-016-1-11
61-MPC-025-1-11
61-MPC-036-1-11
Rated
Current
Leakage Current
(Max.)
Capacitance
CX1
CX2
1A
250VAC
1.6A
2.5A
3.6A
Inductance
(L1)
Temperature
Rise (Max.)
11mH
0.1mA
0.01uF
0.01uF
6.0mH
2.4mH
40°C
1.2mH
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 17.5g
52
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PCB Power Filters
Miniature Printed Circuit Board
61-MPC Series
4
3
4 — .031 (.8)
.551 (14)
2
.767 (19.5)
.059 (1.5)
.590 (15)
1.239 (31.5)
.354
(9)
Dimensions in inches (mm)
Temperature Characteristics
Common Mode
120
1
3
Filter
2
4
Oscillator
50Ω
100
50Ω
Level
Meter
50Ω
1
3
Filter
2
4
(Test circuit 2)
Oscillator
50Ω
Current (%)
Common
mode with
Y cap.
(Test circuit 1)
PCB Power Filters
1
.767 (19.5)
50Ω
Level
Meter
50Ω
80
60
40
20
0
0
30
40
50
60
70
80
Ambient Temperature (°C)
90
100
61-MPC
80
Y Cap
2 X 3300pF
70
Insertion Loss (dB)
61-MPC-010-1-11
Normal Mode
60
50
1
3
Filter
2
4
40
(Test circuit 3)
61-MPC-016-1-11
30
61-MPC-025-1-11
Oscillator
50Ω
20
50Ω
50Ω
Level
Meter
50Ω
61-MPC-036-1-11
10
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
61-MPC
61-MPC
80
80
70
70
60
Insertion Loss (dB)
Insertion Loss (dB)
61-MPC-010-1-11
50
40
30
61-MPC-016-1-11
20
61-MPC-036-1-11
0.5
1
61-MPC-010-1-11
40
61-MPC-016-1-11
30
61-MPC-025-1-11
20
10
10
0.2
50
61-MPC-036-1-11
61-MPC-025-1-11
0
0.1
60
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
53
Power Entry Modules
Bolt-in Right Angle Terminals
for PCB Applications
60-BPP Series
Tested and found to be
IAW VDE 0565 Part 3
Features
■
■
■
■
PCB Power Filters
■
■
■
Ideally suited for products that must
conform to FCC part 15 regulations
Metal case offers high performance
Meets over voltage of IEC 664 category II
and complies with IEC 950
Uses IEC connector that meets most safety standards
Solder lug, Fast-on tab styles available (see page 26)
PCB mounting style minimizes space and provides
economical installation
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 55)
UL approved low leakage version also available
■
■
■
3
1
CY
L1
CX
E
E
Applications
■
Circuit Diagram
CY
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
2
4
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
60-BPP-010-3-2
60-BPP-010-3-4
Leakage Current
(Max.)
CY
Capacitance
0.35mA
2200pF
0.50mA
3300pF
60-BPP-020-3-2
0.35mA
60-BPP-020-3-4
2200pF
0.50mA
3300pF
0.022uF
2.4mH
30°C
0.022uF
0.047uF
250VAC
60-BPP-030-3-2
0.35mA
2200pF
0.022uF
0.047uF
3A
60-BPP-030-5-2
0.50mA
3300pF
0.047uF
60-BPP-060-3-2
0.022uF
0.35mA
2200pF
0.047uF
6A
60-BPP-060-5-2
60-BPP-060-5-4
0.50mA
3300pF
1.2mH
0.022uF
60-BPP-030-5-4
60-BPP-060-3-4
6.0mH
0.022uF
0.047uF
2A
60-BPP-020-5-2
60-BPP-030-3-4
Temperature
Rise (Max.)
0.047uF
60-BPP-010-5-4
60-BPP-020-5-4
Inductance
(L1)
0.022uF
0.047uF
1A
60-BPP-010-5-2
CX
0.53mH
45°C
0.022uF
0.047uF
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 50g
Input: Compatible with IEC-320
54
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Entry Modules
Bolt-in Right Angle Terminals
for PCB Applications
60-BPP Series
.098 (2.5)
120
Current (%)
100
1.463 (37.2)
1.967 (50)
1.317
(33.5)
1.573 (40)
.885
(22.5)
2- .142
(3.6)
80
.047 (1.2)
.232 (5.9)
60
.024
(.6)
5
.
R4
.865
(22)
40
2- .142
(3.6)
1.573 (40)
* General
tolerance
± .012 (.3)
.142
.059 (3.6)
(1.5)
.031 (.8)
1.070
(27.2)
1.180 (30)
.779 1.180
(19.8) (30)
.708
(18)
Panel cutout dimensions
mounts from backside
20
0
.991
(25.2)
.590 (15)
20
30
40
50
60
70
Ambient Temperature (°C)
80
Dimensions in inches (mm)
90
Common Mode
PCB Power Filters
Temperature Characteristics
60-BPP
PCB
Mounting
Type
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
50Ω
50Ω
Level
Meter
50Ω
60-BPP-010;-020
60-BPP-010;-020
80
80
70
70
60
Insertion Loss (dB)
Insertion Loss (dB)
60-BPP-010-3-X
50
60-BPP-020-3-X
40
30
20
60-BPP-010-X-4
50
40
30
60-BPP-020-X-4
20
10
10
0
0.1
60
0.2
0.5
1
2
5
10
20
0
0.1
50
0.2
0.5
1
Frequency (MHz)
5
10
20
50
20
50
60-BPP-030;-060
80
70
70
60
Insertion Loss (dB)
Insertion Loss (dB)
60-BPP-030;-060
80
60-BPP-030-3-X
50
40
60-BPP-060-3-X
30
20
10
0
0.1
2
Frequency (MHz)
60
50
40
60-BPP-030-X-4
30
60-BPP-060-X-4
20
10
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
55
Power Entry Modules
High Frequency Attenuation
Bolt-in for PCB Applications
60-BHP Series
Tested and found to be
IAW VDE 0565 Part 3
Features
■
■
■
■
■
PCB Power Filters
■
■
■
Ideally suited for products that must
conform to FCC part 15 regulations
Metal cased filter offers high performance
Meets over voltage of IEC 664 category II
and complies with IEC 950
Solder lug, Fast-on tab styles available (see page 28)
PCB mounting minimizes space and provides
economical installation
Excellent filtering characteristics for high frequencies
Earth coil standard
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 57)
Circuit Diagram
■
■
■
CY
L1
Applications
■
3
1
CX
E
E
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
CY
2
4
L2
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
60-BHP-010-3-11
Leakage Current
(Max.)
0.35mA
60-BHP-010-3-4
Capacitance
CY
2200pF±20%
0.50mA
3300pF±20%
60-BHP-010-5-4
0.35mA
60-BHP-020-3-4
2200pF±20%
0.50mA
3300pF±20%
0.35mA
2200pF±20%
2.4mH
0.50mA
3300pF±20%
60-BHP-030-5-4
30°C
0.1uF±20%
18.3 uH
0.1uF±20%
.047uF±20%
3A
60-BHP-030-5-11
1.2mH
0.1uF±20%
.047uF±20%
60-BHP-060-3-11
60-BHP-060-5-11
0.1uF±20%
.047uF±20%
250VAC
60-BHP-030-3-11
60-BHP-060-3-4
6mH
0.1uF±20%
.047uF±20%
2A
60-BHP-020-5-11
60-BHP-030-3-4
Temperature
Rise (Max.)
.047uF±20%
60-BHP-020-3-11
60-BHP-020-5-4
Inductance
(L1)
(L2)
0.1uF±20%
.047uF±20%
1A
60-BHP-010-5-11
CX
0.35mA
2200pF±20%
0.1uF±20%
.047uF±20%
6A
0.50mA
60-BHP-060-5-4
3300pF±20%
0.53mH
45°C
0.1uF±20%
.047uF±20%
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 50g
Input: Compatible with IEC-320
56
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Entry Modules
High Frequency Attenuation
Bolt-in for PCB Applications
60-BHP Series
120
.991
(25.2)
.590 (15)
2- .142
(3.6)
.5
2- .142
(3.6)
1.573 (40)
40
.059
(1.5)
.031 (.8)
1.070
(27.2)
.024
(.6)
R4
.865
(22)
.142
(3.6)
.047 (1.2)
.232 (5.9)
1.180 (30)
80
60
1.534 (39)
1.389
(35.3)
.885
(22.5)
100
Current (%)
.098
(2.5)
1.967 (50)
1.573 (40)
.779 1.180
(19.8) (30)
.708 (18)
Panel cutout dimensions
mounts from backside
20
Dimensions in inches (mm)
0
20
30
40
50
60
70
Ambient Temperature (°C)
80
90
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
90
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
60-BHP-XXX-X-11
90
80
Insertion Loss (dB)
Insertion Loss (dB)
60-BHP-020-X-11
50
40
60-BHP-030-X-11
30
60-BHP-060-X-11
60-BHP-010-3-11
50
60-BHP-020-3-11
40
60-BHP-030-3-11
30
60-BHP-060-3-11
10
10
1
0.5
60-BHP-XXX-3-11
60
20
0.2
2
5
10
20
0
0.1
50
0.2
0.5
1
Frequency (MHz)
90
5
10
20
50
60-BHP-XXX-3-4
90
80
80
60-BHP-010-X-4
70
Insertion Loss (dB)
Insertion Loss (dB)
2
Frequency (MHz)
60-BHP-XXX-X-4
60-BHP-020-X-4
60
50
40
60-BHP-030-X-4
30
60-BHP-060-X-4
70
60-BHP-010-3-4
60
50
60-BHP-020-3-4
40
60-BHP-030-3-4
30
60-BHP-060-3-4
20
20
10
10
0
0.1
50Ω
Level
Meter
50Ω
70
20
0
0.1
50Ω
80
60-BHP-010-X-11
70
60
PCB Power Filters
60-BHP
PCB
Mounting
Type
Temperature Characteristics
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
57
PCB Power Filters
Miniature Printed Circuit Board
11-MPC Series
Features
■
■
■
■
■
Miniature general purpose PCB mounted filter
Requires minimal PCB real estate space
Low cost
Operating temperature: -25°C to +70°C
Two forms of cases are available:
metal case and plastic case
Circuit Diagram
Circuit 1
PCB Power Filters
Applications
■
■
■
■
■
Personal computers and peripherals
Digital equipment
Measuring instruments and medical equipment
TV & VCR monitors and display units
Home appliances
Circuit 2
Circuit 3
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
11-MPC-001-2-B
Leakage Current
(Max.)
Circuit
Diagram
Figure
5uA
1
B
1A
11-MPC-001-5-A
A
2
11-MPC-001-5-B
11-MPC-002-5-B
11-MPC-002-5-D
11-MPC-003-5-E
11-MPC-006-5-B
11-MPC-006-5-C
11-MPC-016-5-B
120/250VAC
2A
0.50mA
3A
6A
16A
Temperature Rise
(Max.)
3
2
0.2mA
4
B
D
30°C
E
B
C
B
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 17.5g
58
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PCB Power Filters
Miniature Printed Circuit Board
11-MPC Series
Figure A
Figure C
Figure B
.03 (1) (5X)
0.6 0.9
(16) (25)
.30 (7.5)
2.0
0.9
(25)±.007 (51)
0.6
(16)
0.9 (25)
0.6
(15)
0.4
(10)
1.9 (30)
.30 (7.5)
2.5 (64)
Figure D
.79 (20)
1.1 (29)
0.9 (25)
1.7 (44)
0.6 (15)
±.03
1.4 (36)
.60
(15)
±.07
0.3 (8)
0.3 (8)
.45
(11.5) 1.4
(35)
1.1
(28)
.45
(11.5)
0.6
(16)
1.4 (36)
1.8 (45)
1.4 (35.5)
1.9 (49)
0.6 (15)
±.07
1.1 (27)
Common Mode
.15
(4)
Dimensions in inches (mm)
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
50Ω
PCB Power Filters
Figure E
0.03 (1) (5X)
50Ω
Level
Meter
50Ω
11-MPC-001;-002
11-MPC-001;-002
80
80
11-MPC-002-5-D
70
70
11-MPC-001-5-A
60
11-MPC-001-2-B
50
40
11-MPC-002-5-D
30
20
Insertion Loss (dB)
Insertion Loss (dB)
11-MPC-001-5-B
60
11-MPC-001-5-B
50
11-MPC-001-2-B
40
30
20
11-MPC-001-5-A
11-MPC-002-5-B
10
10
11-MPC-002-5-B
0
0.1
0.2
0.5
1
2
5
10
20
0
0.1
50
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
Frequency (MHz)
11-MPC-003;-006;-016
11-MPC-003;-006;-016
80
80
70
70
60
Insertion Loss (dB)
Insertion Loss (dB)
11-MPC-006-5-C
11-MPC-003-5-E
50
11-MPC-006-5-B
40
30
11-MPC-016-5-B
20
60
11-MPC-016-5-B
50
11-MPC-003-5-E
40
30
11-MPC-006-5-C
20
11-MPC-006-5-B
10
0
0.1
10
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
59
Power Line Filters
Appliance Filters
62-AL/62-AC Series
Features
■
■
■
■
■
■
■
Tested and found to be
IAW VDE 0565 Part 3
Low-cost plastic case
Compact design requires minimal real estate space
Suitable for products that must conform
to FCC regulations
Wide variety of circuit and filtering options
Good filtering characteristics for both normal mode
and common mode
Epoxy molded for reliability
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 61)
Fast-on tab #110
.629
(16.0)
1.220
(31.0)
1.573 (40.0)
.177 x .138 (4.5 x 3.5)
.994 (24.0)
.371
(9.4)
.371
(9.4)
1.527 (38.8)
.657
(16.7)
.374 (9.5)
.263 (6.7)
Applications
■
Power Line Filters
■
■
■
■
■
Dimensions in inches (mm)
Circuit Diagrams
Personal computers and peripherals
Digital equipment
Industrial equipment
Vending machines
Home appliances
Office equipment
L
62-A*L
Series
62-AFL-010-3-11
62-AFC-010-3-11
62-AFL-010-5-11
62-AFC-010-5-11
62-AFL-016-3-11
62-AFC-016-3-11
62-AFL-016-5-11
62-AFC-016-5-11
62-AFL-030-3-11
62-AFC-030-3-11
62-AFL-030-5-11
62-AFC-030-5-11
62-AFL-045-3-11
62-AFC-045-3-11
62-AFL-045-5-11
62-AFC-045-5-11
62-AFL-060-3-11
62-AFC-060-3-11
62-AFL-060-5-11
62-AFC-060-5-11
Rated
Current
Leakage Current
(Max.)
CY
Capacitance
0.35mA
2200pF
0.50mA
3300pF
0.35mA
2200pF
0.50mA
3300pF
0.35mA
2200pF
0.50mA
3300pF
0.35mA
2200pF
0.50mA
3300pF
0.35mA
2200pF
0.50mA
3300pF
R
CX
CY1
CY2
Inductance
(L1)
Temperature
Rise (Max.)
11.0mH
1.6A
6.0mH
0.1uF
3.0A
4.5A
2.4mH
40°C
1.0mH
6.0A
0.53mH
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3
Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max.
60
CX
1.0A
250VAC
CY2
* R= w/ Bleeder Resistor
F = w/o Bleeder Resistor
Specifications
Rated Voltage
(@ 50/60Hz)
CY1
L
62-A*C
Series
Model*
CX
R
* Available with bleeder resistor
Replace F with R for part number
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Temperature Characteristics
120
100
Current (%)
Power Line Filters
Appliance Filters
80
60
40
20
0
Normal
20 Mode
30
40
50
60
70
Ambient Temperature (°C)
62-AL/62-AC Series
Common Mode
80
90
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
50Ω
50Ω
Level
Meter
50Ω
62-AFL-XXX-3-11
62-AFL-xxx-3-11
80
80
62-AFL-030-3-11
70
62-AFL-045-3-11
70
62-AFL-010-3-11
50
40
30
20
60
62-AFL-016-3-11
50
62-AFL-010-3-11
40
30
62-AFL-030-3-11
20
62-AFL-060-3-11
62-AFL-060-3-11
10
10
62-AFL-045-3-11
0
0.1
0.2
0.5
1
2
10
5
20
0
0.1
50
0.2
0.5
1
5
10
62-AFC-030-3-11
62-AFC-030-3-11
70
62-AFC-016-3-11
60
Insertion Loss (dB)
62-AFC-016-3-11
62-AFC-010-3-11
50
40
30
20
60
50
62-AFC-010-3-11
40
30
62-AFC-045-3-11
62-AFC-060-3-11
20
62-AFC-060-3-11
10
10
62-AFC-045-3-11
0
0.1
0.2
0.5
1
2
10
5
20
0
0.1
50
0.2
0.5
1
62-AFL-030-5-11
20
50
20
50
70
62-AFL-016-5-11
62-AFL-010-5-11
Insertion Loss (dB)
62-AFL-016-5-11
40
30
62-AFL-045-5-11
20
62-AFL-030-5-11
60
62-AFL-010-5-11
50
40
30
20
62-AFL-060-5-11
62-AFL-060-5-11
10
10
0
0.1
0.2
0.5
1
2
5
10
20
62-AFL-045-5-11
0
0.1
50
0.2
0.5
1
2
5
10
Frequency (MHz)
Frequency (MHz)
62-AFC-xxx-5-11
62-AFC-xxx-5-11
80
80
70
70
62-AFC-016-5-11
62-AFC-010-5-11
Insertion Loss (dB)
Insertion Loss (dB)
10
80
50
60
5
62-AFL-xxx-5-11
62-AFL-xxx-5-11
80
Insertion Loss (dB)
2
Frequency (MHz)
Frequency (MHz)
60
50
80
70
70
20
62-AFC-XXX-3-11
62-AFC-XXX-3-11
80
Insertion Loss (dB)
2
Frequency (MHz)
Frequency (MHz)
Power Line Filters
60
Insertion Loss (dB)
Insertion Loss (dB)
62-AFL-016-3-11
50
40
30
62-AFC-060-5-11
20
62-AFC-045-5-11
62-AFC-030-5-11
62-AFC-016-5-11
10
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
10
20
62-AFC-030-5-11
60
62-AFC-010-5-11
50
40
30
20
62-AFC-045-5-11
10
50
0
0.1
62-AFC-060-5-11
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
61
Power Line Filters
Single Stage
62-PPF/PQF/PRF Series
Tested and found to be
IAW VDE 0565 Part 3
Features
■
■
■
■
■
■
■
Low-cost plastic case
Compact design requires minimal real estate space
Suitable for products that must conform
to FCC and FTZ regulations
Wide variety of circuit and filtering options
Good filtering characteristics for both normal mode
and common mode
Epoxy molded for reliability
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 63)
Applications
■
Power Line Filters
■
■
■
■
Circuit Diagrams
L1
62-PQF-020-5-11
62-PQF-020-5-12
62-PPF-020-5-11
62-PPF-020-5-12
62-PQF-030-5-11
62-PQF-030-5-12
62-PPF-030-5-11
62-PPF-030-5-12
62-PQF-060-5-11
62-PQF-060-5-12
62-PPF-060-5-11
62-PPF-060-5-12
62-PRF-010-5-11
62-PRF-010-5-12
62-PRF-020-5-11
62-PRF-020-5-12
62-PRF-030-5-11
62-PRF-030-5-12
Rated Voltage
(@ 50/60Hz)
CY
CY
CY
CX
R
CY
L1
L1
62-PRF*
Series
R
CX
CY
CY
* Bleeder Resistor is available only for
62-P(Q/R/P)F-XXX-X-12
Specifications
Model
R
L1
62-PPF*
Series
Personal computers and peripherals
Digital equipment
Industrial equipment
Vending machines
Office equipment
CX
62-PQF*
Series
Rated
Current
Leakage Current
(Max.)
Capacitance
CY
2A
3A
0.50mA
250VAC
3300pF
6A
1A
2A
3A
CX
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
Inductance
(L1)
Temperature
Rise (Max.)
15mH
8mH
30°C
2.1mH
486uH
181uH
97uH
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3
Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. (except 62-PRF-010-5-11) at rated current
62-PRF-010-5-11: 1.5V max. at rated current
Weight: 62-PPF & PQF Series: 2.11 ounces (60 grams)
62-PRF Series: 1.76 ounces (50 grams)
62
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Line Filters
Single Stage
62-PPF/PQF/PRF Series
Temperature Characteristics
Normal Mode
120
1
3
Filter
2
4
Current (%)
100
Oscillator
50Ω
80
50Ω
50Ω
Level
Meter
50Ω
60
40
62-PQF Series
80
20
70
20
30
40
50
60
70
Ambient Temperature (°C)
80
90
Fast-on tab #110
50
40
62-PQF-020-5-11
30
62-PQF-060-5-12
20
62-PQF-060-5-11
10
0
0.1
.786
(20)
0.2
1
0.5
.177 x .138 (4.5 x 3.5)
5
10
20
50
10
20
50
10
20
50
62-PPF Series
2.006 (51)
1.947 (49.5)
.354
(9)
2
Frequency (MHz)
1.573 (40)
.354
(9)
Power Line Filters
0
Insertion Loss (dB)
62-PQF-020-5-12
60
80
1.265 (32)
.590 (15)
Dimensions in inches (mm)
Also available with .250 Fast-ons
Common Mode
Insertion Loss (dB)
70
.904
(23)
60
50
62-PPF-020-5-12
40
62-PPF-020-5-11
30
62-PPF-060-5-12
20
62-PPF-060-5-11
10
1
3
Filter
2
4
Oscillator
50Ω
0
0.1
50Ω
Level
Meter
50Ω
0.2
1
0.5
2
5
Frequency (MHz)
62-PRF Series
62-P(P/Q/R)F Series
80
80
70
60
60
Insertion Loss (dB)
Insertion Loss (dB)
62-P(Q/P)-060-5-11
70
50
40
30
62-P(Q/P)-020-5-11
20
50
62-PRF-010-5-11
40
62-PRF-010-5-12
30
62-PRF-030-5-12
20
62-P(Q/P)-030-5-11
62-PRF-030-5-11
10
0
0.1
10
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
63
Power Line Filters
Single Stage Wire Leads
62-PML Series
Tested and found to be
IAW VDE 0565 Part 3
Features
■
■
■
■
■
■
■
Compact design requires minimal real estate space
Suitable for products that must conform
to FCC and FTZ regulations
Excellent attenuation for high voltage impulse
Metal case provides effective shielding
Excellent filtering characteristics for both normal mode
and common mode
Structure provides effective shielding for noise
generated externally and internally
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 65)
Circuit Diagram
1
3
CY
L1
CX
CX
R
Applications
Power Line Filters
■
■
■
■
■
E
Digital equipment
Personal computers and peripherals
Measuring instruments
Medical equipment
Factory automation equipment
CY
4
2
Specifications
Model
Rated Voltage
(@ 50/60Hz)
62-PML-015-3-11
Rated
Current
1.5A
62-PML-015-5-11
62-PML-030-3-11
62-PML-030-5-11
62-PML-050-3-11
62-PML-050-5-11
62-PML-100-5-11
3A
250VAC
5A
10A
Leakage Current
(Max.)
CY
Capacitance
0.35mA
2200pF
0.50mA
3300pF
0.35mA
2200pF
0.50mA
3300pF
0.35mA
2200pF
0.50mA
3300pF
0.50mA
3300pF
CX
Inductance
(L1)
Temperature
Rise (Max.)
10.0mH
4.3mH
30°C
0.1uF
2.4mH
2.2mH
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3
Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 62-PML-015 Series: 3.06 ounces (87 grams)
62-PML-030 Series: 3.17 ounces (90 grams)
62-PML-050 Series: 3.28 ounces (93 grams)
Discharge time: 0.4 sec. max.
64
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Line Filters
Single Stage Wire Leads
62-PML Series
BK
Temperature Characteristics
WH
G/Y
120
BK
1.219
(31)
.786
(20) 1.966
(50)
WH
PVC
Insulated wire
AWG # 20 UL1015
100
.629
(16)
2 — .138 x .181 (3.5 x 4.6)
.944 (24)
80
60
.395 (10)
.395
(10)
5.112* (130)
40
5.112* (130)
20
* Custom lengths available upon request. Dimensions in inches (mm)
0
20
30
40
50
60
70
80
1.856 (47.2)
90
Power Line Filters
Current (%)
1.573
(40)
Ambient Temperature (°C)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
50Ω
50Ω
Level
Meter
50Ω
80
70
62-PML
90
40
30
62-PML-050-5-21
20
10
0
0.1
62-PML
80
62-PML-030-5-21
50
Insertion Loss (dB)
Insertion Loss (dB)
62-PML-015-5-21
60
70
60
62-PML-050-5-11
50
40
62-PML-030-5-11
30
62-PML-015-5-11
20
0.2
0.5
1
2
5
10
20
50
10
Frequency (MHz)
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
65
Power Line Filters
Single Stage Wire Leads
for Medical Purpose Applications
12-PML & 12-PMF Series
Features
■
■
■
■
■
■
■
■
Compact design requires minimal real estate
space
Suitable for products that must conform
to FCC and FTZ regulations
Excellent attenuation for high voltage impulse
Metal case provides effective shielding
Excellent filtering characteristics for both normal
mode and common mode
Structure provides effective shielding for noise
generated externally and internally
Operating temperature: -25°C to +70°C
Low leakage current
Circuit Diagram
Circuit 1
Circuit 2
Power Line Filters
Applications
■
■
■
■
■
Digital equipment
Personal computers and peripherals
Measuring instruments
Medical equipment
Factory automation equipment
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
12-PML-001-2-A
1A
12-PML-002-2-A
2A
12-PML-006-2-A
6A
12-PML-010-2-A
12-PMF-001-2-B
120/250VAC
10A
1A
12-PMF-002-2-B
2A
12-PMF-006-2-B
6A
12-PML-001-2-C
1A
Leakage Current
(Max.)
Circuit
Diagram
Figure
1
A
5uA
Temperature Rise
(Max.)
30°C
2
B
1
C
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3
Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Discharge time: 0.4 sec. max.
66
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Line Filters
Single Stage Wire Leads
for Medical Purpose Applications
12-PML & 12-PMF Series
Figure A
Figure C
.31 (8)
.13 (3.5) X .17 (4.5) SLOT (2 PLACES)
.13 (3.5) X .17 (4.5) SLOT (2 PLACES)
.94
(24)
1.5
(39)
1.9
(49)
1.2
(30)
1.25 (32)
1.6 (42)
1.9 (48)
1.7 (44)
.78 (20)
.78 (20)
Figure B
.14 (3.8) (2X)
1.2
(30)
1.7 (44)
.79 (20)
2.2 (56)
2.4 (61)
Common Mode
Power Line Filters
Dimensions in inches (mm)
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
12-PML-001;-002;-006;-010
50Ω
50Ω
Level
Meter
50Ω
12-PML-001;-002;-006;-010
80
80
70
70
12-PML-002-2-A
12-PML-006-2-A
60
12-PML-001-2-A
Insertion Loss (dB)
Insertion Loss (dB)
12-PML-001-2-A
12-PML-006-2-A
50
40
30
20
12-PML-002-2-A
10
0
0.1
50
40
30
20
12-PML-010-2-A
10
12-PML-010-2-A
0.2
60
0.5
1
2
5
10
20
0
0.1
50
0.2
0.5
1
2
Frequency (MHz)
70
70
12-PMF-001-2-B
12-PMF-002-2-B
50
40
30
20
12-PMF-006-2-B
10
0
0.1
0.5
1
2
5
Frequency (MHz)
10
12-PMF-001-2-B
20
50
20
50
12-PMF-002-2-B
60
50
11-PML-001-2-C
40
30
20
12-PMF-006-2-B
10
11-PML-001-2-C
0.2
10
12-PMF-001;-002;-006;-010
80
Insertion Loss (dB)
Insertion Loss (dB)
12-PMF-001;-002;-006;-010
80
60
5
Frequency (MHz)
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
67
Power Line Filters
Single Stage
62-LMF & LMB Series
Tested and found to be
IAW VDE 0565 Part 3
Features
■
■
■
■
■
■
■
Space saving, compact designs
Suitable for products that must conform
to FCC and FTZ regulations
Excellent filtering characteristics for both normal mode
and common mode
Structure provides effective shielding for noise
generated externally and internally
Metal case provides effective shielding
Rugged construction
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 69)
Circuit Diagram
CY
1
Power Line Filters
■
■
■
CX
CX
R
Applications
■
3
L1
CY
Digital equipment
Office automation equipment, such as copy
and fax machines
Computers and peripherals
Instrumentation and controls
E
4
2
Specifications
Model*
Rated Voltage
(@ 50/60Hz)
62-LMB-030-5-11
Rated
Current
Leakage Current
(Max.)
Capacitance
CX
Inductance
(L1)
3A
0.1uF
14mH
5A
0.1uF & .22uF
7.0mH
8A
.22uF
4.2mH
10A
.33uF
2.2mH
CY
Temperature
Rise (Max.)
62-LMF-030-5-11
62-LMB-050-5-11
62-LMF-050-5-11
62-LMB-080-5-11
62-LMF-080-5-11
62-LMB-100-5-11
250VAC
0.50mA
62-LMF-100-5-11
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Discharge time: 0.4 sec. max.
Weight: 5.3 ounces (150 grams)
68
45°C
3300pF
*62-LMF - designates Fast-on terminals
62-LMB - designates Bolt-in terminals
62-LML - wire lead in/outputs also available
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Temperature Characteristics
120
100
Current (%)
Power Line Filters
Single Stage
80
60
40
20
62-LMF & LMB Series
0
30
40
50
60
70
Ambient Temperature (°C)
80
90
62-LMF
62-LMB
.708
(18.0)
20
1.10
(28.0)
1.97
(50.0)
.66
(16.8)
.66
(16.8)
.255
(6.5)
.61
(15.5)
1.10
(28.0)
.708
(18.0)
.61
(15.5)
1.97
(50.0)
2 - ø4.8
.255
(6.5)
5-M4
2.39
(60.7± 0.5)
1.97
(50.0)
1.22
(31.0)
2.79
(70.9)
.61
(15.5)
1.97
(50.0)
2.79
(70.9)
.61
(15.5)
Fast-on Tabs #250
.031 (0.8) t
2 - ø .188
(4.8)
Dimensions in inches (mm)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
Power Line Filters
1.22
(31.0)
2.39
(60.7± 0.5)
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
62-LMF & LMB
50Ω
50Ω
Level
Meter
50Ω
62-LMF & LMB
90
90
80
80
70
62-LM-030-5-11
Insertion Loss (dB)
Insertion Loss (dB)
62-LM-030-5-11
62-LM-050-5-11
60
50
40
30
62-LM-100-5-11
20
0.5
60
50
40
62-LM-100-5-11
30
62-LM-080-5-11
10
10
0.2
70
20
62-LM-080-5-11
0
0.1
62-LM-050-5-11
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
69
Power Line Filters
Single Stage
62-PMF & PMB Series
Tested and found to be
IAW VDE 0565 Part 3
Features
■
■
■
■
■
■
■
■
Space-saving, compact designs
Suitable for products that must conform
to FCC regulations
Excellent attenuation for high voltage impulse
Metal case provides effective EMI shielding
Excellent filtering characteristics for both normal mode
and common mode
Epoxy molded for internal component reliability
Structure provides effective shielding for noise
generated externally and internally
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 71)
Circuit Diagram
CY
1
3
L1
CX
CX
R
CY
E
Applications
Power Line Filters
■
■
■
■
■
■
■
■
■
4
2
Digital equipment
Computers and peripherals
Measuring instruments
Medical equipment
Equipment requiring very high impulse attenuation
Factory automation equipment
Industrial equipment such as UPS, inverters
and converters
Telecommunications equipment
Office automation equipment, such as copy
and fax machines
Specifications
Model*
Rated Voltage
(@ 50/60Hz)
62-PMB-050-5-11
Rated
Current
Leakage Current
(Max.)
Capacitance
CX
Inductance
(L1)
5A
0.1uF
14mH
8A
.1uF & .22uF
7.0mH
.22uF
4.2mH
CY
Temperature
Rise (Max.)
62-PMF-050-5-11
62-PMB-080-5-11
62-PMF-080-5-11
62-PMB-100-5-12
62-PMF-100-5-12
62-PMB-150-5-13
62-PMF-150-5-13
250VAC
10A
2.2mH
35°C
1.8mH
45°C**
.33uF
20A
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max.
Discharge time: 0.4 sec. max.
Weight: 8.82 ounces ( 250 grams)
70
3300pF
15A
62-PMB-200-5-13
62-PMF-200-5-13
0.50mA
30°C
* PMF - designates Fast-on terminals
PMB - designates Bolt-in terminals
** The temperature rise of 20 amp units can be decreased to 30°C
by mounting on 200 X 200 x 1.0(mm) steel chassis
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Line Filters
Single Stage
62-PMF & PMB Series
62-PMF
3.291 (83.7)
B
C
Fast-on tab
#250
2.937 (74.7)
Temperature Characteristics
1.258
(32)
120
2 — .197 (5)
.610
(15.5)
.315
(8)
A
62-PMB
80
3.291 (83.7)
B
2.937 (74.7)
5 — .157
(M4)
60
C
2 — .197
(5)
1.258
(32)
1.998
(50.8)
40
MODEL
30
40
50
60
70
Ambient Temperature (°C)
80
90
Common Mode
B
C
1.490 .944 .433
(38) (24) (11)
62-PMF/PMB-050-080
1.258 .786
(32) (20)
0
(0)
Dimensions in inches (mm)
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
62-PMB-050-6
50Ω
50Ω
Level
Meter
50Ω
62-PMB-050-6
R2
R1
S1 Filter S2
T1
T2
50Ω
Level
Meter
Oscillator
50Ω
90
90
80
80
50Ω
50Ω
50Ω
R2
R1
S1 Filter S2
T1
T2
Oscillator
50Ω
Insertion Loss (dB)
60
50
40
62-PMB-100-5-12
30
62-PMB-150-5-13
20
62-PMF-050-5-11
70
60
50
40
62-PMF-150-5-13
30
20
62-PMB-200-5-13
10
50Ω
Level
Meter
62-PMB-200-5-13
62-PMB-050-5-11
62-PMB-080-5-11
0
0.1
A
62-PMF/PMB-100-200
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
.315
(8)
A
50Ω
20
50Ω
0
70
.649
(16.5)
2.497 (63.5)
Power Line Filters
.649
(16.5)
20
Insertion Loss (dB)
.610
(15.5)
2.497 (63.5)
50Ω
Current (%)
100
1.998
(50.8)
62-PMF-080-5-11
10
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
62-PMF-100-5-12
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
71
Power Line Filters
Single Stage
12-PMF Series
Features
■
■
■
■
■
■
■
■
Space-saving, compact designs
Suitable for products that must conform
to FCC regulations
Excellent attenuation for high voltage impulse
Metal case provides effective EMI shielding
Excellent filtering characteristics for both normal mode
and common mode
Epoxy molded for internal component reliability
Structure provides effective shielding for noise
generated externally and internally
Operating temperature: -40°C to +85°C
Circuit Diagram
Circuit 1
Circuit 2
Circuit 3
Circuit 4
Circuit 5
Circuit 6
Applications
■
Power Line Filters
■
■
■
■
■
■
■
■
Digital equipment
Computers and peripherals
Measuring instruments
Medical equipment
Equipment requiring very high impulse attenuation
Factory automation equipment
Industrial equipment such as UPS, inverters
and converters
Telecommunications equipment
Office automation equipment, such as copy
and fax machines
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
Leakage Current
(Max.)
Circuit
Diagram
Figure
12-PMF-001-5-A
1A
1
A
12-PMF-002-5-B
2A
2
B
4
A
2
B
12-PMF-003-5-A
3A
12-PMF-003-5-B
12-PMF-006-5-A
6A
12-PMF-006-5-C
12-PMF-006-5-D
12-PMF-010-5-A
12-PMF-010-5-C
12-PMF-015-5-C
12-PMF-015-5-E
120/250VAC
10A
A
1
C
6
D
2
A
3
15A
20A
12-PMF-020-5-E
30°C
C
E
5
12-PMF-020-5-C
12-PMF-020-5-D
0.5mA
4
Temperature Rise
(Max.)
C
D
E
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max.
Discharge time: 0.4 sec. max.
72
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Line Filters
Single Stage
12-PMF Series
Figure A
Figure B
.14 (3.8)
2 .34 (8.8)
1.2
(30)
2.4 1.8
(62) (46)
2.1
(54)
1.7 (44)
2.2 (56)
.78 (20)
3.2 (81)
1.25 (32)
2.4 (62)
.86 (22)
Figure D
Figure C
Figure E
.41 (10.5)
2 .17 (8.8)
2-
1.7 (4.5) (2X)
.18 (4.8)
2.0
(52)
2.0 (52)
2.4 (63)
1.9 2.3 2.8
(50) (60) (10.5)
1.4 (37)
2.5 3.3
(64) (85)
2.9
(74)
3.2 (82)
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
12-PMF-001;-002;-003;-006
12-PMF-006-5-C
12-PMF-001-5-A
70
12-PMF-001-5-A
12-PMF-006-5-A
12-PMF-002-5-B
12-PMF-003-5-B
12-PMF-006-5-A
40
12-PMF-003-5-A
12-PMF-006-5-C
30
20
12-PMF-006-5-D
60
12-PMF-006-5-D
50
40
30
12-PMF-003-5-B
20
12-PMF-003-5-A
10
10
0
0.1
12-PMF-002-5-B
0.2
0.5
1
2
5
10
20
0
0.1
50
0.2
0.5
1
Frequency (MHz)
12-PMF-001;-002;-003;-006
12-PMF-006-5-A
40
12-PMF-003-5-A
12-PMF-006-5-C
30
20
Insertion Loss (dB)
Insertion Loss (dB)
12-PMF-003-5-B
50
12-PMF-015-5-E
60
12-PMF-020-5-C
50
40
12-PMF-010-5-A
30
20
12-PMF-020-5-D
12-PMF-020-5-E
12-PMF-006-5-D
10
10
0.5
20
12-PMF-010-5-C
12-PMF-002-5-B
0.2
10
70
12-PMF-001-5-A
0
0.1
5
12-PMF-010;-015;-020
80
70
50
2
Frequency (MHz)
80
60
50Ω
Level
Meter
50Ω
80
Insertion Loss (dB)
Insertion Loss (dB)
50
50Ω
12-PMF-001;-002;-003;-006
80
70
1.4 (36)
3.1 (80)
Common Mode
60
2.0 (51)
1.1 (28)
2.9 (74)
Power Line Filters
1.7 (44)
Dimensions in inches (mm)
1
2
5
Frequency (MHz)
10
20
50
0
0.1
12-PMF-015-5-C
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
73
Power Line Filters
Single Stage - Higher Current
62-PMB Series
Features
■
■
■
■
■
■
■
■
■
Power Line Filters
■
Space-saving, compact designs
Suitable for products that must conform
to FCC regulations
Excellent attenuation for high voltage impulse
Metal case provides effective shielding
Excellent filtering characteristics for both normal mode
and common mode
Epoxy molded for internal component reliability
Structure provides effective shielding for noise
generated externally and internally
Safety agency approvals pending
Designed to be in accordance with VDE 0565 Part 3
Operating temperature: -25°C to +85°C
(including temperature rise)
Circuit Diagram
3
1
L1
CX
CY
CX
R
E
CY
L1
4
2
Applications
■
■
■
■
■
■
■
■
■
Digital equipment
Computers and peripherals
Measuring instruments
Medical equipment
Equipment requiring very high impulse attenuation
Factory automation equipment
Industrial equipment such as UPS, inverters
and converters
Telecommunications equipment
Office automation equipment, such as copy
and fax machines
Specifications
Model
Rated Voltage
(@ 50/60Hz)
62-PMB-300-5-14
Rated
Current
CY
Capacitance
CX
0.50mA
3300pF
.47uF
40A
Inductance
(L1)
Temperature
Rise (Max.)
1.6mH
30A
250VAC
62-PMB-400-5-14
Leakage Current
(Max.)
45°C
0.8mH
Note: Test voltage: 1500VAC one minute, line to earth
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max.
Discharge time: 0.4 sec. max.
Weight: 8.82 ounces (250 grams)
74
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Line Filters
Single Stage - Higher Current
62-PMB Series
62-PMB-300-5-14 and 62-PMB-400-5-14
4.13 (105)
3.74 (95±.08)
3.15 (80)
0.511
(13.0)
3.70 (94)
3.85 (98)
1.022
(26.0)
5.591 (142.00)
2.049 (52.0)
Dimensions in inches (mm)
Common Mode
Normal Mode
1
3
1
4
2
50 ohm
LEVEL
METER
50 ohm
90
90
80
80
70
70
60
62-PMB-400-5-14
40
30
20
10
0
0.1
50 ohm
LEVEL
METER
50 ohm
60
50
62-PMB-300-5-14
40
30
20
62-PMB-300-5-14
4
OSCILLATOR
50 ohm
Insertion Loss (dB)
Insertion Loss (dB)
50 ohm
50
3
FILTER
FILTER
2
OSCILLATOR
50 ohm
Power Line Filters
3.03 (77±0.5)
62-PMB-400-5-14
10
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
75
Power Line Filters
Single Stage - Higher Current
12-PMB Series
Features
■
■
■
■
■
■
■
■
■
Space-saving, compact designs
Suitable for products that must conform
to FCC regulations
Excellent attenuation for high voltage impulse
Metal case provides effective shielding
Excellent filtering characteristics for both normal mode
and common mode
Epoxy molded for internal component reliability
Structure provides effective shielding for noise
generated externally and internally
Designed to be in accordance with VDE 0565 Part 3
Operating temperature: -40°C to +85°C
Circuit Diagram
Power Line Filters
■
■
■
■
■
■
■
■
L1
CX
CY
CX
R
L1
Applications
■
3
1
E
CY
4
2
Digital equipment
Computers and peripherals
Measuring instruments
Medical equipment
Equipment requiring very high impulse attenuation
Factory automation equipment
Industrial equipment such as UPS, inverters
and converters
Telecommunications equipment
Office automation equipment, such as copy
and fax machines
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
12-PMB-025-5-A
25A
12-PMB-030-5-A
30A
12-PMB-035-5-B
12-PMB-050-5-B
120/250VAC
Leakage Current
(Max.)
100A
120A
Temperature Rise
(Max.)
A
1
50A
12-PMB-120-8-C
Figure
0.5mA
35A
12-PMB-100-8-C
Circuit
Diagram
1.0mA
B
30°C
C
Note: Test voltage: 1500VAC one minute, line to earth
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max.
Discharge time: 0.4 sec. max.
Weight: 8.82 ounces (250 grams)
76
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Line Filters
Single Stage - Higher Current
12-PMB Series
Figure A
1M4 STUD
(4X)
Figure B
.17 (4.5) ±.007
(2X)
M4 THREAD (10X)
Figure C
0.2 (6.3)
0.5 (4.5)
2.0
(24) ±.03
2.0
(52)
0.16 (4.2) X 0.25 (6.4) (2X)
M8 THREAD (4X)
4.3 4.5 5.1
(110) (115) (130)
3.3 3.7 4.1
(84) (95) (105)
0.2 (6) ±.03
2.5 (64) MAX
2.9 (75) ±.01
0.8 (22)
±.03
1.4 (37) MAX
3.9 (101) MAX
1.9 (50)
2.0 (51)
3.9 (98.5)
1.5 (38.5)
3.1 (80)
4.7 (120)
7.0 (180)
5.3 (135)
Common Mode
Power Line Filters
Dimensions in inches (mm)
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
50Ω
50Ω
Level
Meter
50Ω
12-PMB-025;-030;-035
12-PMB-025;-030;-035
80
80
70
70
60
Insertion Loss (dB)
Insertion Loss (dB)
12-PMB-035-5-B
12-PMB-025-5-A
50
40
30
12-PMB-035-5-B
20
60
50
12-PMB-025-5-A
40
12-PMB-030-5-A
30
20
12-PMB-030-5-A
10
10
0
0.1
0.2
0.5
1
2
10
5
20
0
0.1
50
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
Frequency (MHz)
12-PMB-050;-100;-120
12-PMB-050;-100;-120
80
80
70
70
12-PMB-050-5-B
Insertion Loss (dB)
Insertion Loss (dB)
12-PMB-100-8-C
60
50
40
30
12-PMB-050-5-B
20
60
50
12-PMB-120-8-C
40
12-PMB-100-8-C
30
20
12-PMB-120-8-C
10
0
0.1
10
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
77
Power Line Filters
DC - Higher Current
12-PMF & 12 PMB DC Series
Features
■
■
■
■
■
■
■
■
■
Space-saving, compact designs
Suitable for products that must conform to FCC regulations
Excellent attenuation for high voltage impulse
Metal case provides effective shielding
Excellent filtering characteristics for both normal mode
and common mode
Epoxy molded for internal component reliability
Structure provides effective shielding for noise
generated externally and internally
Designed to be in accordance with VDE 0565 Part 3
Operating temperature: -40°C to +85°C
Circuit Diagram
Circuit 1
Applications
■
Power Line Filters
■
■
■
■
■
■
Circuit 2
Digital equipment
Computers and peripherals
Measuring instruments
Equipment requiring very high impulse attenuation
Factory automation equipment
Industrial equipment such as UPS, inverters and converters
Telecommunications equipment
Specifications
Model
12-PMF-006-DC-C
12-PMF-010-DC-C
12-PMF-015-DC-C
12-PMF-020-DC-C
12-PMF-025-DC-D
12-PMB-025-DC-F
12-PMB-030-DC-F
12-PMB-035-DC-F
12-PMB-040-DC-F
12-PMB-040-DC-B
12-PMB-050-DC-B
12-PMB-060-DC-B
12-PMB-080-DC-G
12-PMB-080-DC-C
12-PMB-100-DC-C
12-PMB-120-DC-C
12-PMB-140-DC-C
12-PMB-180-DC-E
12-PMB-200-DC-E
12-PMB-260-DC-E
Rated Voltage
(@ 50/60Hz)
Rated
Current
Circuit
Diagram
6A
10A
15A
20A
30A
35A
Figure
Temperature Rise
(Max.)
A
B
25A
1
C
40A
48/250
VDC
50A
60A
80A
100A
120A
140A
180A
200A
260A
Note: Test voltage: 1500VAC one minute, line to earth
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max.
78
Circuit 3
D
2
3
2
30°C
E
F
G
Discharge time: 0.4 sec. max.
Weight: 8.82 ounces (250 grams)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Figure A
Power Line Filters
DC - Higher Current
12-PMF & 12-PMB DC Series
Figure B
Figure C
Figure D
Figure E
Figure F
Figure G
Power Line Filters
1.9 (50)
±.003
Dimensions in inches (mm)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
12-PMF-006;-010;-015;-020;-025
80
12-PMF-006;-010;-015;-020;-025
12-PMF-025-DC-D
70
60
Insertion Loss (dB)
Insertion Loss (dB)
12-PMF-010-DC-C
50
12-PMF-025-DC-D
40
30
12-PMF-015-DC-C
20
12-PMF-020-DC-C
10
60
12-PMF-020-DC-C
50
12-PMF-010-DC-C
40
12-PMF-015-DC-C
30
12-PMF-006-DC-C
20
10
0.2
0.5
1
2
5
10
20
0
0.1
50
0.2
0.5
1
Frequency (MHz)
12-PMB-080-DC-G
12-PMB-080-DC-C
12-PMB-025-DC-F
12-PMB-030-DC-F
12-PMB-035-DC-F
12-PMB-040-DC-F
20
50
40
12-PMB-180-DC-E
12-PMB-200-DC-E
12-PMB-260-DC-E
30
20
12-PMB-040-DC-B
12-PMB-050-DC-B
12-PMB-060-DC-B
12-PMB-100-DC-C
12-PMB-120-DC-C
12-PMB-140-DC-C
10
0.2
0.5
1
2
5
Frequency (MHz)
70
Insertion Loss (dB)
Insertion Loss (dB)
10
80
50
0
0.1
5
12-PMB-025; thru -260
12-PMB-025; thru -260
60
2
Frequency (MHz)
80
70
50Ω
Level
Meter
50Ω
80
12-PMF-006-DC-C
70
0
0.1
50Ω
10
20
60
40
12-PMB-080-DC-G
12-PMB-080-DC-C
30
20
10
50
12-PMB-025-DC-F
12-PMB-030-DC-F
12-PMB-035-DC-F
12-PMB-040-DC-F
50
0
0.1
12-PMB-180-DC-E
12-PMB-200-DC-E
12-PMB-260-DC-E
0.2
0.5
12-PMB-040-DC-B
12-PMB-050-DC-B
12-PMB-060-DC-B
1
2
12-PMB-100-DC-C
12-PMB-120-DC-C
12-PMB-140-DC-C
5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
79
Power Line Filters
Dual Stage
62-MMF Series
Features
■
■
■
■
■
■
■
Suitable for products that must conform
to FCC regulations
Excellent attenuation for high voltage impulse
Metal case provides effective EMI shielding
Two stages for excellent filtering characteristics
Epoxy molded for reliability
Structure provides effective shielding for noise
generated both externally and internally
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 81)
Circuit Diagram
62-MMF-XXX-7-11
1
L1
CX
R
Applications
■
Power Line Filters
■
■
■
■
CX
CY
CX
CY
Digital equipment
Personal computers and peripherals
Measuring instruments and medical equipment
Telecommunications equipment
Equipment requiring very high noise attenuation
3
L1
CY
CY
2
E
4
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
Leakage Current
(Max.)
CY1
Capacitance
CY2
CX
Inductance
(L1) (2X)
Temperature
Rise (Max.)
62-MMF-030-7-11
250VAC
3A
.7mA
3300pF
1000pF
0.1uF
3.7mH
30°C
62-MMF-050-7-11
250VAC
5A
.7mA
3300pF
1000pF
0.1uF
2.9mH
30°C
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3
Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Leakage current: 0.7 mA max.
Voltage drop: 1V max.
Discharge time: 0.4 sec. max.
Weight: 6.0 ounces (170 grams)
80
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Line Filters
Dual Stage
62-MMF Series
Temperature Characteristics
3.291 (83.7)
120
.786 (20)
.315
(8)
Fast-on tab
#250
2.937 (74.7)
Current (%)
100
80
.315
(8)
2 – .197 (5)
1.258
(32)
1.998
(50.8)
60
.610
(15.5)
40
.610
(15.5)
2.497 (63.5)
1.258 (32)
20
Dimensions in inches (mm)
20
30
40
50
60
70
80
90
Power Line Filters
0
Ambient Temperature (°C)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
90
80
80
70
70
60
62-MMF-050-7-11
50
62-MMF-030-7-11
40
30
20
60
62-MMF-050-7-11
50
62-MMF-030-7-11
40
30
20
10
0
0.1
50Ω
Level
Meter
50Ω
62-MMF
90
Insertion Loss (dB)
Insertion Loss (dB)
62-MMF
50Ω
10
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
81
Power Line Filters
Dual Stage
12-MMF & 12-MMB Series
Features
■
Suitable for products that must conform
to FCC regulations
Excellent attenuation for high voltage impulse
Metal case provides effective EMI shielding
Two stages for excellent filtering characteristics
Structure provides effective shielding for noise
generated both externally and internally
Operating temperature: -40°C to +85°C
■
High performance
■
Low leakage current
■
■
■
■
■
Circuit Diagram
Circuit 1
Applications
■
Power Line Filters
■
■
■
■
■
Circuit 2
Digital equipment
Switching power supplies
Personal computers and peripherals
Measuring instruments and medical equipment
Telecommunications equipment
Equipment requiring very high noise attenuation
Circuit 3
Specifications
Model
12-MMF-002-5-F
12-MMF-003-5-F
12-MMF-003-5-A
12-MMF-006-5-F
12-MMF-006-5-G
12-MMF-008-5-B
12-MMF-010-5-F
12-MMF-010-5-G
12-MMF-010-5-B
12-MMF-012-5-B
12-MMB-015-5-E
12-MMB-020-5-F
12-MMB-030-5-D
12-MMB-050-5-C
Rated Voltage
(@ 50/60Hz)
Rated
Current
Leakage
Current (Max.)
2A
1
3A
120/250VAC
Circuit
Diagram
3
Figure
A
B
C
6A
B
8A
D
10A
0.5mA
B
2
12A
15A
20A
30A
50A
Temperature Rise
(Max.)
30°C
D
E
D
F
G
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3
Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Leakage current: 0.7 mA max.
Voltage drop: 1V max.
Discharge time: 0.4 sec. max.
82
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Figure C
Power Line Filters
Dual Stage
2.12
(54)
1.81 2.44
(46) (62)
12-MMF & 12-MMB Series
Figure A
Ø .15 (3.8) (2X)
1.26 (32)
.87 (22)
2.44 (62)
Figure B
Figure D
Ø .25 (6.4) (2X)
2.00
(51)
2.24
(57)
2.00 ± .02 (75 ± .5)
3.35 (85) MAX
Figure E
Figure F
M4 THREAD (5X)
M4 STUD (7X)
2.90 (73)
2.42 (87)
4.01 (102)
1.77 (45)
Figure G
.117 (4.5) X .25 (6.3) SLOT (4X)
M4 THREAD
.21 (5.4) X .37 (9.4) HOLE (4X)
M6 THREAD (4X)
3.30 3.74 4.13
(84) (95) (105)
.71 (18)
1.50 (38)
6.30 (160)
7.24 (184)
7.95 (202)
2.30 (58)
1.51 (38.5)
3.93 4.52 5.12
(100) (115) (130)
2.01 (51)
3.88 (98.5)
5.31 (135)
1.97 (50)
3.15 (80)
4.72 (120)
7.09 (180)
Dimensions in inches (mm)
Common Mode
Power Line Filters
2.40 ± .007
(60 ± .2)
3.38 1.65
(86) (42)
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
12-MMF-002;-003;-006;-008
50Ω
50Ω
Level
Meter
50Ω
12-MMF-002;-003;-006;-008
80
80
70
70
60
Insertion Loss (dB)
Insertion Loss (dB)
12-MMF-006-5-G
12-MMF-002-5-F
50
12-MMF-003-5-F
40
12-MMF-006-5-F
12-MMF-006-5-G
30
20
12-MMF-008-5-B
60
12-MMF-002-5-F
50
12-MMF-006-5-F
12-MMF-003-5-F
40
12-MMF-008-5-B
30
20
12-MMF-003-5-A
10
10
0
0.01
12-MMF-003-5-A
0.05
0.15 0.45 1
2
5
10
20
0
0.01
50
0.05
0.15 0.45 1
Frequency (MHz)
2
5
10
20
50
Frequency (MHz)
12-MMF-010;-012;-015;-020;-030;-050
12-MMF-010;-012;015;-020;-030;-050
80
80
70
70
60
12-MMB-030-5-D
50
12-MMB-050-5-C
40
12-MMB-015-5-E
12-MMF-010-5-F
12-MMF-010-5-G 12-MMB-020-5-F
12-MMF-010-5-B
12-MMF-012-5-B
30
20
10
0
0.01
0.05
0.15 0.45 1
2
5
Frequency (MHz)
10
20
50
Insertion Loss (dB)
Insertion Loss (dB)
12-MMB-050-5-C
60
50
40
12-MMB-030-5-D
30
12-MMF-010-5-F
12-MMF-010-5-G
12-MMF-010-5-B
12-MMF-012-5-B
12-MMB-015-5-E
12-MMB-020-5-F
20
10
0
0.01
0.05
0.15 0.45 1
2
5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
83
Power Line Filters
Dual Stage
12-MMF & 12-MMB Series
Features
■
Suitable for products that must conform
to FCC regulations
Excellent attenuation for high voltage impulse
Metal case provides effective EMI shielding
Two stages for excellent filtering characteristics
Structure provides effective shielding for noise
generated both externally and internally
Operating temperature: -40°C to +85°C
■
High performance
■
■
■
■
■
Circuit Diagram
Circuit 1
Applications
■
■
Power Line Filters
■
■
■
Digital equipment
Personal computers and peripherals
Measuring instruments and medical equipment
Telecommunications equipment
Equipment requiring very high noise attenuation
Circuit 2
Specifications
Model
12-MMF-003-11-F
12-MMF-006-11-F
12-MMF-010-11-F
12-MMB-012-11-A
12-MMB-015-11-G
12-MMB-020-11-D
12-MMB-030-11-D
12-MMB-040-11-B
12-MMB-040-11-E
12-MMB-050-11-H
Rated Voltage
(@ 50/60Hz)
120/250VAC
Rated
Current
3A
6A
10A
12A
15A
20A
30A
Leakage
Current (Max.)
1.5mA
40A
50A
Circuit
Diagram
Figure
1
A
2
B
C
1
2
1
Temperature Rise
(Max.)
30°C
B
D
E
F
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3
Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Leakage current: 0.7 mA max.
Voltage drop: 1V max.
Discharge time: 0.4 sec. max.
Weight: 6.0 ounces (170 grams)
84
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Line Filters
Dual Stage
12-MMF & 12-MMB Series
Figure C
Figure B
Ø .18 ± .007 (2X)
(4.5 ± 0.2)
3.74
1.73 3.33
± .02
± .04 MAX
(44 ± 1) (84.5) (95 ± 0.5)
.75 ± .04 (19 ± 1)
1.53 MAX (39)
Figure D
4.13
MAX
(105)
2.24
(57)
2.01 ± .02
(51 ± 0.5)
3.90 MAX (99)
6.20 MAX (157)
Figure F
.25 (6.4) x .37(9.4) SLOT (4X)
2.28
(58)
1.77 (45)
.95
(24.1)
2.24
(57)
.35 (9)
.90 (23)
8.66 (220)
9.57 (243)
10.27 (261)
3.54
(90)
.165 (4.2) X .25 (6.4) (4X)
M8 THREAD (4X)
.177 (4.5) X .25 (6.5) SLOT (2X)
3.54 5.90
(90) (150)
2.90 (73)
3.42 (87)
4.30 (109)
1.80 (45)
Figure E
M6 THREAD (5X)
M4 THREAD (4X)
1.77
(45)
3.93 4.53 5.12
(100) (115) (130)
2.91 (74)
3.66 (93)
4.01 (102)
1.97
(50)
3.14 (80)
4.72 (120)
7.08 (180)
Dimensions in inches (mm)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
50Ω
50Ω
Level
Meter
50Ω
12-MMF-003;-006;-010;-012;-015
12-MMF-003;-006;-010;-012;-015
120
120
12-MMF-003-11-F
12-MMF-012-11-A
105
105
12-MMF-003-11-F
12-MMF-012-11-A
90
Insertion Loss (dB)
Insertion Loss (dB)
Power Line Filters
Figure A
75
60
12-MMF-006-11-F
45
12-MMF-010-11-F
30
15
0
0.1
90
75
60
45
12-MMF-015-11-G
30
12-MMF-006-11-F
12-MMF-015-11-G
15
12-MMF-010-11-F
0
0.2
0.5
1
2
5
10
20
0.1
50
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
Frequency (MHz)
12-MMF-020;-030;-040;-050
12-MMF-020;-030;-040;-050
120
120
12-MMF-040-11-B
12-MMF-020-11-D
105
105
90
90
Insertion Loss (dB)
Insertion Loss (dB)
12-MMF-040-11-B
75
60
45
30
75
60
45
12-MMF-050-11-H
30
12-MMF-040-11-E
12-MMF-040-11-E
15
0.2
0.5
1
12-MMF-020-11-D
12-MMF-050-11-H
0
0.1
12-MMF-030-11-D
15
12-MMF-030-11-D
2
5
Frequency (MHz)
10
0
20
50
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
85
Power Line Filters
Dual Stage
12-MMF & 12-MMB Series
Features
■
■
■
■
■
■
■
Suitable for products that must conform
to FCC regulations
Excellent attenuation for high voltage impulse
Metal case provides effective EMI shielding
Two stages for excellent filtering characteristics
Epoxy molded for reliability
Structure provides effective shielding for noise
generated both externally and internally
Operating temperature: -25°C to +85°C
Circuit Diagram
Circuit 1
Applications
■
■
Power Line Filters
■
■
■
Digital equipment
Personal computers and peripherals
Measuring instruments and medical equipment
Telecommunications equipment
Equipment requiring very high noise attenuation
Circuit 2
Circuit 3
Specifications
Model
12-MMF-001-5-F
12-MMF-003-5-G
12-MMF-003-2-G
12-MMF-006-5-G
12-MMB-010-5-D
12-MMB-015-5-E
12-MMB-020-5-E
12-MMB-030-5-E
Rated Voltage
(@ 50/60Hz)
Rated
Current
1A
3A
120/250VAC
6A
10A
15A
20A
30A
Leakage
Current (Max.)
Circuit
Diagram
0.5mA
3
5uA
1
Figure
A
B
C
0.5mA
Temperature Rise
(Max.)
30°C
2
D
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3
Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Leakage current: 0.7 mA max.
Voltage drop: 1V max.
Discharge time: 0.4 sec. max.
Weight: 6.0 ounces (170 grams)
86
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Line Filters
Dual Stage
12-MMF & 12-MMB Series
Figure B
Figure A
2.01
(51)
2.52 (64)
2.95 (75)
3.70 (94)
1.06 (27)
M4 THREAD (5X)
Figure D
.25 (6.4) .37 (9.4) HOLE (4X)
M4 STUD (7X)
3.33
1.73 ± .03 (84.5)
(44 ± 1)
MAX
3.74 ± .02
(95 ± 0.5)
4.13 MAX.
(64)
0.75 ± .03 (19 ± 1)
2.36 ± .007
(60 ± .2)
3.38 1.65
(86) (42)
2.01 ± .02
(51 ± .05)
1.52 (39)
MAX
2.28 (58)
3.15 (99) MAX
5.31 (135) MAX
Dimensions in inches (mm)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
7.09 (180)
7.24 (184)
7.95 (202)
.71 (18)
1.50 (38)
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
12-MMF-001;-003;-006
50Ω
12-MMF-001;-003;-006
120
120
12-MMF-006-5-G
12-MMF-006-5-G
105
105
12-MMF-003-2-G
90
Insertion Loss (dB)
Insertion Loss (dB)
12-MMF-003-5-G
75
60
45
30
12-MMF-003-2-G
12-MMF-001-5-F
15
0
0.1
90
75
60
12-MMF-003-5-G
45
30
12-MMF-001-5-F
15
0
0.2
0.5
1
2
10
5
20
0.1
50
0.2
0.5
1
Frequency (MHz)
2
5
10
20
50
Frequency (MHz)
12-MMB-010;-015;-020;-030
12-MMB-010;-015;-020;-030
120
120
12-MMB-010-5-D
12-MMB-015-5-E
105
105
12-MMB-020-5-E
90
Insertion Loss (dB)
Insertion Loss (dB)
50Ω
Level
Meter
50Ω
Power Line Filters
Figure C
75
60
12-MMB-030-5-E
45
30
12-MMB-010-5-D
12-MMB-015-5-E
12-MMB-020-5-E
90
75
12-MMB-030-5-E
60
45
30
15
15
0
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
87
Power Line Filters
Three Phase
Low Current/High Performance
62-PMB/63-PMF Series
Features
■
■
■
■
■
■
■
■
■
Excellent attenuation for high voltage impulse
Effective for both balanced and unbalanced
three-phase loads
Metal case provides effective EMI shielding
Epoxy molded for internal component reliability
Compact and economical
Excellent filtering characteristics for both normal
and common mode
Various current ratings available: 3, 5, 8 and 16 Amps
Safety agency approvals pending
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 89)
Power Line Filters
■
■
■
62-PMB-050-6-12 (5 Amp Delta)
L
L
L
L
CX
CX
CY
CX
L
CY
L
CY
63-PMF-030-8-14 and 63-PMF-080-8-14 (3 and 8 Amp Wye)
Applications
■
Circuit Diagram
CX
L
Digital equipment
Industrial equipment (UPS, inverters
and converters)
Automation equipment
Computerized washing machines
CY
L
CY
CX
L
CX
CY
L
CY
63-PMF-160-9-21 (16 Amp Wye)
L
L
L
CX
CX
CX
CX CX CX
L
CY
CY
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
Leakage Current
(Max.)
CY
CX
Inductance
(L1)
Temperature
Rise (Max.)
62-PMB-050-6-12
250VAC
5A
0.6mA
2200pF
0.22uF
115mH
45°C
1.0mA
4700pF (4X)
470uF (3X)
3.0mA
0.015uF (2X)
1.0uF (6X)
3A
63-PMF-030-8-14
63-PMF-080-8-14
63-PMF-160-9-21
420VAC
8A
16A
Capacitance
1.0mH (4X)
30°C
0.74mH (4X)
40°C
1.2mH (4X)
45°C
Note: Test Voltage 1500VAC one minute, line to ground.
Insulation Resistance: 300 MΩ min. at 500VDC.
Voltage Drop: 1V max. at rated current.
Weight: 8.82 ounces (250 grams) for 63-PMF-030-8-14 and 63-PMF-080-8-14
19.4 ounces (550 grams) for 62-PMB-050-6-12
51.5 ounces (1450 grams) for 63-PMF-160-9-21
88
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Temperature Characteristics
Power Line Filters
Three Phase
Low Current/High Performance
62-PMB/63-PMF Series
62-PMB-050-6-12 (5 Amp)
5 — .157
(M4)
.865 (22)
2.753
(70)
3.460 3.539
(88) (90)
.865 (22)
.039 (1)
1.376
(35)
63-PMF-030-8-14 and 63-PMF-080-8-14 (3 and 8 Amp)
4.444 (113)
4.050 (103)
Fast-on
tab #250
2 - .197
(ø5) Hole
.629
(16)
.708
(18)
BL
BK
BL
.547
(13.9)
.547
(13.9)
3.585 (91.2)
1.809
(46)
Dimensions in inches (mm)
4 - .216
(ø5.5) Hole
Fast on
tab #250
2.045
(52)
.983
(25)
63-PMF-160-9-21 (16 Amp)
BK
.208
(5.3)
.350 (8.9)
.362
(9.2)
4.404
(112) .350 (8.9)
.350 (8.9)
4.286
(109)
Fast on
tab #250
(Ground
tab)
3.146
(80.0±0.5)
5.112 (130.0)
5.702 (145 ± 0.5)
6.292 (160)
Common Mode
Normal Mode
62-PMB-050-6-12 (5 Amp)
62-PMB-050-6-12 (5 Amp)
63-PMF (3, 8 and 16 Amp)
63-PMF (3, 8 and 16 Amp)
* General
tolerance
±..059 (1.5)
1.494 (38)
2.359 (60)
.708
(18)
Power Line Filters
* General .944 (24)
tolerance
±.020 (0.5)
63-PMF-160-9-21
63-PMF-160-9-21
63-PMF-080-8-14
63-PMF-030-8-14
63-PMB-050-8-12
63-PMF-030-8-14
63-PMF-080-8-14
63-PMB-050-8-12
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
89
Power Line Filters
Three Phase
13-PWF/PWL/PWB Series
Features
■
Excellent attenuation for high voltage impulse
Effective for both balanced and unbalanced
three-phase loads
Metal case provides effective EMI shielding
Epoxy molded for internal component reliability
Suitable for both Wye and Delta connection
Excellent filtering characteristics for both normal
and common mode
Operating temperature: -40°C to +85°C
■
Designed for 3-phase 4-line power supply systems
■
■
■
■
■
■
Circuit Diagram
Circuit 1
Applications
■
Power Line Filters
■
■
■
Digital equipment
Industrial equipment (UPS, inverters
and converters)
Automation equipment
Computerized washing machines
A
A'
B
B'
C
C'
N
G
N'
Circuit 2
A
A'
B
B'
C
C'
N
G
N'
Specifications
Model
13-PWF-005-12-H
13-PWL-005-12-C
13-PWF-010-12-H
13-PWL-010-12-C
13-PWB-010-12-D
13-PWB-015-12-D
13-PWB-020-12-D
13-PWB-025-12-D
13-PWB-030-12-D
Rated Voltage
(@ 50/60Hz)
Rated
Current
Leakage
Current (Max.)
Circuit
Diagram
Figure
1
A
B
A
B
5A
10A
1.5mA
440/250VAC
15A
20A
25A
30A
Temperature Rise
(Max.)
30°C
2
C
Note: Test Voltage 1500VAC one minute, line to ground.
Insulation Resistance: 300 MΩ min. at 500VDC.
Voltage Drop: 1V max. at rated current.
90
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Figure B
Power Line Filters
Three Phase
13-PWF/PWL/PWB Series
Figure A
Figure C
2.0 (51)
3.9 (98.5)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
13-PWF-005;-010;-PWL-005;-010;-PWB-010
13-PWB-010-12-D
70
Insertion Loss (dB)
60
50
40
13-PWF-010-12-H
13-PWL-010-12-C
30
13-PWB-010-12-D
20
10
60
50
40
13-PWF-005-12-H
13-PWL-005-12-C
30
20
13-PWF-010-12-H
13-PWL-010-12-C
10
0.2
0.5
1
2
5
10
20
0
0.1
50
0.2
0.5
1
Frequency (MHz)
13-PWB-015;-020;-025:-030
5
10
20
50
10
20
50
13-PWB-015;-020;-025:-030
80
70
13-PWB-015-12-D
13-PWB-020-12-D
13-PWB-025-12-D
70
13-PWB-015-12-D
13-PWB-020-12-D
13-PWB-025-12-D
60
50
Insertion Loss (dB)
Insertion Loss (dB)
2
Frequency (MHz)
80
40
30
13-PWB-030-12-D
20
10
0
0.1
50Ω
Level
Meter
50Ω
80
13-PWF-005-12-H
13-PWL-005-12-C
70
Insertion Loss (dB)
50Ω
13-PWF-005;-010;-PWL-005;-010;-PWB-010
80
0
0.1
Power Line Filters
5.3 (135)
Dimensions in inches (mm)
60
50
40
13-PWB-030-12-D
30
20
10
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
91
Power Line Filters
Three Phase
13-PDF/PDL/PDB Series
Features
■
Excellent attenuation for high voltage impulse
Effective for both balanced and unbalanced
three-phase loads
Metal case provides effective EMI shielding
Epoxy molded for internal component reliability
Compact and economical
Excellent filtering characteristics for both normal
and common mode
Operating temperature: -40°C to +85°C
■
Designed for 3-phase, 3-Delta connection system
■
■
■
■
■
■
Circuit Diagram
Circuit 1
Applications
■
Power Line Filters
■
■
■
Digital equipment
Industrial equipment (UPS, inverters
and converters)
Automation equipment
Switching power supplies
A
A'
B
B'
C
C'
G
Circuit 2
A
A'
B
B'
C
C'
G
Specifications
Model
13-PDF-005-11-J
13-PDL-005-11-D
13-PDF-010-11-J
13-PDL-010-11-D
13-PDB-010-11-D
13-PDB-015-11-D
13-PDB-020-11-D
13-PDB-025-11-D
13-PDB-030-11-D
Rated Voltage
(@ 50/60Hz)
Rated
Current
Leakage
Current (Max.)
Circuit
Diagram
Figure
1
A
B
A
B
5A
10A
1.5mA
440/250VAC
15A
20A
25A
30A
Temperature Rise
(Max.)
30°C
2
C
Note: Test Voltage 1500VAC one minute, line to ground.
Insulation Resistance: 300 MΩ min. at 500VDC.
Voltage Drop: 1V max. at rated current.
92
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Figure B
Ø .177 (4.5) (2X)
Power Line Filters
Three Phase
2.00
(51)
13-PDF/PDL/PDB Series
2.52 (64)
1.06
(27)
2.95 (75)
3.35 (85)
Figure A
Figure C
Ø .177 (4.5) (2X)
.25 (6.3)
M4
THREAD
(10X)
.117 (4.5)
2.52 2.91 3.35
(64) (74) (85)
3.31 3.74 4.13
(84) (95) (105)
1.42
(36)
2.00
(51)
2.00 (51)
3.88 (98.5)
1.51
(38.5)
3.15 (80)
5.31 (135)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
13-PDF-005;-010; PDL-005;-010 PDB-010
50Ω
Level
Meter
50Ω
80
13-PDF-005-11-J
13-PDL-005-11-D
70
13-PDB-010-11-D
70
60
Insertion Loss (dB)
Insertion Loss (dB)
50Ω
13-PDF-005;-010; PDL-005;-010 PDB-010
80
50
40
13-PDB-010-11-D
30
13-PDF-010-11-J
13-PDL-010-11-D
20
10
60
50
13-PDF-010-11-J
13-PDL-010-11-D
40
30
13-PDF-005-11-J
13-PDL-005-11-D
20
10
0
0.1
0.2
0.5
1
2
5
10
20
0
0.1
50
0.2
0.5
1
Frequency (MHz)
13-PDB-015;-020;-025:-030
5
10
20
50
10
20
50
13-PDB-015;-020;-025:-030
80
70
70
13-PDB-015-11-D
13-PDB-020-11-D
13-PDB-025-11-D
13-PDB-030-11-D
Insertion Loss (dB)
60
50
40
30
13-PDB-030-11-D
20
10
0
0.1
2
Frequency (MHz)
80
Insertion Loss (dB)
Power Line Filters
Dimensions in inches (mm)
60
50
40
13-PDB-015-11-D
13-PDB-020-11-D
13-PDB-025-11-D
30
20
10
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
93
Power Line Filters
Three Phase
High Performance
13-PWB Series
Features
■
Excellent attenuation for high voltage impulse
Metal case provides effective EMI shielding
Epoxy molded for internal component reliability
Excellent filtering characteristics for both normal
and common mode
Various current ratings available: from 5 to 150 Amps
Operating temperature: -40°C to +85°C
■
Designed for 3-phase, 4-line power systems
■
■
■
■
■
Applications
■
■
Power Line Filters
■
■
Power supplies for data systems
Industrial equipment (UPS, inverters
and converters)
Automation equipment
Telecommunications systems and equipment
Circuit Diagram
Circuit 1
A
A'
B
B'
C
C'
N
G
N'
Circuit 2
A
A'
B
B'
C
C'
N
G
N'
Specifications
Model
13-PWB-005-12-A
13-PWB-010-12-B
13-PWB-020-12-B
13-PWB-035-12-C
13-PWB-050-13-C
13-PWB-080-14-D
13-PWB-100-14-D
13-PWB-150-14-E
Rated Voltage
(@ 50/60Hz)
Rated
Current
440/250VAC
5A
10A
20A
35A
50A
80A
100A
150A
Leakage
Current (Max.)
Circuit
Diagram
4.5mA
1
30°C
9.0mA
20mA
Temperature Rise
(Max.)
2
Note: Test Voltage 1500VAC one minute, line to ground.
Insulation Resistance: 300 MΩ min. at 500VDC.
Voltage Drop: 1V max. at rated current.
94
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Line Filters
Three Phase
H
High Performance
I
L
P
M E
F D
13-PWB Series
K
B
A
C
G
N
J
Dimensions
Dimensions in inches (mm)
B
C
13-PWB-005-12-A 7.2 (184) 6.3 (160) 7.9 (202)
13-PWB-010-12-B
13-PWB-020-12-B
13-PWB-035-12-C
9.6
(243)
8.7
(220)
10.3
(261)
13-PWB-080-14-D
13.9
(354)
12.6
(320)
E
2.4
(60)
1.7
(44)
3.1
(81)
13-PWB-050-13-C
13-PWB-100-14-D
D
3.9
(99)
15.1
(384)
13-PWB-150-14-E
F
G
H
I
J
3.5 (86) .70 (18) 2.3 (58)
3.9
(100)
3.8
(96)
4.9
(125)
6.1
(155)
7.3
(185)
M
N
P
3.5
(90)
M6
–
–
–
M4
2.9
(74)
1.9
(49)
M6
2.2
(56)
M8
.25 x .37 (6.4 x 9.4)
1.8
(45)
M8
.25 x .37 (6.4 x 9.5)
.25 x .38 (6.4 x 9.6)
2.3
(58)
M4
1.2
(30)
3.4
(86)
2.4
(62)
7.5 (190) 8.7 (220) 1.4 (35) 3.9 (100)
.25 x .38 (6.4 x 9.7)
.25 x .38 (6.4 x 9.8)
.25 x .39 (6.4 x 9.9)
.25 x .36 (6.4 x 9.10)
.25 x .36 (6.4 x 9.11)
2.4 (61)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
50Ω
50Ω
Level
Meter
50Ω
13-PWB-005;-010;-020;-035
13-PWB-005;-010;-020;-035
120
120
13-PWB-010-12-A
105
13-PWB-005-12-A
105
13-PWB-010-12-A
13-PWB-020-12-A
90
Insertion Loss (dB)
Insertion Loss (dB)
L
1.5 (38)
M4
.98
(25)
K
Power Line Filters
A
Model
75
13-PWB-020-12-A
60
13-PWB-035-12-A
45
30
90
75
60
13-PWB-035-12-A
45
30
13-PWB-005-12-A
15
15
0
0.1
0
0.2
0.5
1
2
5
10
20
0.1
50
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
Frequency (MHz)
13-PWB-050;-080;-100;-150
13-PWB-050;-080;-100;-150
120
120
13-PWB-080-14-D
13-PWB-100-14-D
13-PWB-080-14-D
105
105
90
75
60
13-PWB-150-14-E
13-PWB-050-13-C
45
30
15
Insertion Loss (dB)
Insertion Loss (dB)
13-PWB-100-14-D
90
75
13-PWB-050-13-C
60
45
13-PWB-150-14-E
30
15
0
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
95
Power Line Filters
Three Phase
High Performance
13-PDB Series
Features
■
Excellent attenuation for high voltage impulse
Metal case provides effective EMI shielding
Epoxy molded for internal component reliability
Excellent filtering characteristics for both normal
and common mode
Various current ratings available: from 5 to 200 Amps
Operating temperature: -40°C to +85°C
■
Designed for 3-phase, 3-line connection systems
■
■
■
■
■
Applications
■
■
Digital equipment
Industrial equipment (UPS, inverters
and converters)
Circuit Diagram
Circuit 1
A
A'
B
B'
C
C'
G
Power Line Filters
Circuit 2
A
A'
B
B'
C
C'
G
Specifications
Model
13-PDB-005-12-A
13-PDB-010-12-A
13-PDB-020-12-B
13-PDB-035-12-B
13-PDB-050-13-B
13-PDB-080-13-C
13-PDB-100-14-C
13-PDB-150-14-C
13-PDB-200-14-D
Rated Voltage
(@ 50/60Hz)
Rated
Current
440/250VAC
5A
10A
20A
35A
50A
80A
100A
150A
200A
Leakage
Current (Max.)
Circuit
Diagram
Temperature Rise
(Max.)
4.5mA
1
30°C
9.0mA
20mA
2
Note: Test Voltage 2250VDC one minute, line to ground.
Insulation Resistance: 500MΩ.
96
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Line Filters
Three Phase
High Performance
I
L
P
H
F D
M E
13-PDB Series
B
A
C
G
N
J
K
Dimensions
Model
A
B
C
D
E
F
G
H
I
J
K
M
N
Dimensions in inches (mm)
P
L
13-PDB-005-12-A
7.2
(184)
6.3
(160)
7.9
(202)
1.6
(42)
2.4
(60)
3.3
(86)
.70
(18)
2.3
(58)
M4
1.5
(38)
–
–
–
M4
9.6
(243)
8.7
(220)
10.3
(261)
2.3
(58)
2.7
(70)
3.9
(100)
.98
(25)
M6
2.3
(58)
1.9
(49)
M6
13-PDB-020-12-B
13-PDB-035-12-B
13-PDB-050-13-B
13-PDB-100-14-C
13.9
(354)
13-PDB-150-14-C
12.6
(320)
15.1
(384)
6.1
(155)
2.5
(66)
13-PDB-200-14-D
7.3
(185)
.25 x .37 (6.4 x 9.5)
.25 x .38 (6.4 x 9.6)
.25 x .38 (6.4 x 9.7)
.25 x .38 (6.4 x 9.8)
3.5
(90)
13-PDB-080-13-C
2.9
(74)
.25 x .37 (6.4 x 9.4)
M4
1.2
(30)
M8
3.3
(86)
2.4
(62)
.25 x .39 (6.4 x 9.9)
2.2
(56)
M8
Common Mode
.25 x .36 (6.4 x 9.11)
.25 x .36 (6.4 x 9.12)
2.4 (61)
7.5 (190) 8.6 (220) 1.4 (35) 3.9 (100)
.25 x .36 (6.4 x 9.10)
Power Line Filters
13-PDB-010-12-A
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
13-PDB-005;-010;-020;-035
50Ω
50Ω
Level
Meter
50Ω
13-PDB-005;-010;-020;-035
120
120
13-PDB-010-12-A
105
13-PDB-020-12-B
13-PDB-005-12-A
90
Insertion Loss (dB)
Insertion Loss (dB)
105
75
60
13-PDB-035-12-B
45
13-PDB-005-12-A
30
15
0
0
0.02
.1
1
10
75
60
45
13-PDB-035-12-B
30
13-PDB-020-12-B
15
13-PDB-010-12-A
0.01
90
20
30
0
0
60
0.01
0.02
.1
Frequency (MHz)
13-PDB-050;-080;-100;-150;-200
10
30
60
120
105
105
90
13-PDB-080-13-C
75
60
45
13-PDB-150-14-C
30
Insertion Loss (dB)
13-PDB-100-14-C
13-PDB-050-13-B
13-PDB-100-14-C
13-PDB-050-13-B
90
13-PDB-200-14-D
75
60
45
13-PDB-080-13-C
30
13-PDB-150-14-C
13-PDB-200-14-D
15
0
0
20
13-PDB-050;-080;-100;-150;-200
120
Insertion Loss (dB)
1
Frequency (MHz)
15
0.01
0.02
.1
1
10
Frequency (MHz)
20
30
60
0
0
0.01
0.02
.1
1
10
20
30
60
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
97
Military/Aerospace
Multisection Filters
Features
■
■
■
■
■
■
■
High common and differential mode attenuation
Standard designs up to 100 Amps
Excellent insertion loss characteristics up to 1 GHz
Voltage rating 115-250VAC and 400VDC up to 400 Hz
Available to meet MIL-F-15733 and MIL-STD-461
standards
Available to meet TEMPEST and FCC requirements
Custom designs available
The High Performance Power Line Filters shown on pages
99 through 105 are designed to meet the following criteria.
The information shown can be used as a basis for
filter specifications. (Contact factory for additional details).
Applications
■
■
Military/Aerospace Multisection Filters
■
■
■
Military
Commercial &
military/aerospace
Secured communications
Switching power supplies
Data processing equipment
■
■
■
■
■
Ruggedized computers
Radar
Electronic warfare
Ground/air weapon systems
Satellites
Test Specifications
Test
Group
Order
of
Test
Examination
or Test
Test Method
(Per MIL-STD-202)
Post Test
Requirements
1
Voltage Drop
Paragraph 4.6.8 of MIL-F-15733
Three percent of rated voltage max.
2
Leakage Current
UL 1283
Per applicable specification
3
Temperature Rise
MIL-F-15733 Paragraph 4.6.4
25°C max.
4
Terminal Strength
Method 211, Condition A
No evidence of loosening or rupture.
5 lb. applied force. Line Cords: 35 Lbs.
1
Shock, Medium Impact
Method 213, Condition G
Must pass DWV and Insertion Loss
2
Vibration, High Frequency
Method 204, Condition A
Monitor for shorts or open
3
Thermal Shock
Method 107, Test Condition A
Pass 90% DWV IR to be 30% of initial
4
Humidity
Method 107, Condition B, except
temperature equals 25°C
Pass 90% DWV IR to be 30% of initial
1
Life
Method 108, Condition D 1.2 x Rated AC voltage
at max. operating temp. or 1.4 x DC voltage
Pass 90% DWV insulation resistance
to be 30% of initial.
IIA
IIB
III
98
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Military/Aerospace
Multisection Filters
Insertion Loss
52-600-001
Insertion Loss (dB)
80
differential
mode
60
Circuit Schematic
40
common mode
20
0
0.01
0.1
1
10
Frequency (MHz)
100
1000
100
1000
LINE
LOAD
52-600-002
60
common mode
40
differential mode
20
0
0.01
0.1
1
10
Frequency (MHz)
Military/Aerospace Multisection Filters
Insertion Loss (dB)
80
Dimensions
1.250
(31.75)
.250 Fast-on tabs (3 PL.)
.240
(6.10)
SWITCH
52-600-001
52-600-002
.215
(5.46)
FUSE
CONNECTOR
.250
(6.35)
2.500
(63.50)
.625
(15.8)
1.68
(42.67)
2.98
(75.70)
Dimensions in inches (mm)
Model
Temperature
Rating
DCR.
max.
(ohms)
Leakage
Current
(max.)
Mode
(max.)
52-600-001
5A
120/240VAC
-40°C to +65°C
.20
1 mA
60 Hz
120/240VAC
60 Hz
2.120 ± .010
(53.85)
3.88
(98.55)
Voltage
Rating
10A
.03 R.
4 PL
2.500
(63.50)
CHASSIS
MOUNTING
HOLE
#6-32 THREADED
INSERTS (4 PL.)
(3.50-32)
Current
Rating
52-600-002
1.250
(31.75)
-40°C to +65°C
.10
1 mA
Minimum Insertion Loss
(db) Per MIL-STD-220
50K 150K 300K 1M
10M 100M 1G
COMM
33
65
80
80
80
80
60
DIFF
37
65
80
80
80
–
–
COMM
–
50
70
80
80
70
60
DIFF
25
50
75
80
80
–
–
Consult factory for UL/CSA approval availability.
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
99
HIGH PERFORMANCE
Military/Aerospace
Power Line Filters for C.O.T.S./
Multisection
Filters
TEMPEST Applications
# 52-600-001
52-600-002
Circuit Schematic
Insertion Loss
52-523-002
52-523-002
LINE
Insertion Loss (dB)
80
LOAD
60
40
20
0
0.01
0.1
1
10
Frequency (MHz)
100
1000
Dimensions
Military/Aerospace Multisection Filters
52-523-002
.750
(19.05)
.600
(15.24)
2.010
(51.05)
.250
(6.35)
.250
(6.35)
3.000
(76.2)
.375
(9.52)
FUSEHOLDER
1.75
.875 (44.4)
(22.2)
3.50
.875 (88.9)
(22.2)
PLUG
#6-32 THDED
INSERT 4 PLCS.
(3.50-32)
4.00
(101.6)
.625
(15.8)
1.25
(31.75)
Dimensions in inches (mm)
Model
Current
Rating
Voltage
Rating
Temperature
Rating
DCR
max.
(ohms)
Leakage
Current
(max.)
Mode
(max.)
52-523-002
5A
120/240VAC
-40°C to +65°C
.25
1 mA
COMM
–
55
60
80
80
70
60
DIFF
–
50
60
80
80
–
–
60 Hz
Minimum Insertion Loss
(db) Per MIL-STD-220
50K 150K 300K 1M
10M 100M 1G
Consult factory for UL/CSA approval availability.
100
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Military/Aerospace
Multisection Filters
Insertion Loss
1212-0502
Insertion Loss (dB)
80
Circuit Schematic
60
1212-0502
40
20
0
0.01
0.1
1
10
Frequency (MHz)
100
1000
Dimensions
.219 TYP.
(5.56)
.656
(16.41)
.418
(10.62)
1.000
(25.4)
.500
(12.7)
.209
(5.31)
.120 TYP.
(3.05)
.594
± .031
± (.78)
1.187 ± .015
(30.15 ± .38)
1.125
(28.58)
MOUNTING
SURFACE
.032
(.81)
.125 6-PLCS.
(3.18 ± .00)
.875
(22.23)
1.250
(31.75)
.105 TYP.
(2.67)
.281 ± .031
(7.14 ± .78)
.710
(18.03)
.187
(4.75)
1.437 ± .031
(36.50 ± .78)
Dimensions in inches (mm)
Model
Current
Rating
1212-0502
10A
Voltage
Rating
350VDC
Temperature
Rating
-55°C to +125°C
DCR
max.
(ohms)
Leakage
Current
(max.)
Cx
Value
.01
1 mA
5000pF
Military/Aerospace Multisection Filters
.055 TYP.
(1.40)
1212-0502
Minimum Insertion Loss
(db) Per MIL-STD-220
10M
100M
500M
1G
20
65
70
70
240VAC 60 Hz
Consult factory for UL/CSA approval availability.
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
101
Military/Aerospace
Multisection Filters
Secure Communications
Spectrum's electromagnetic compatibility expertise in
the secure communication or “TEMPEST” arena is represented by this group of high performance filters. These
units are especially well suited for use in MIL-STD-461
applications to reduce conducted emissions. The filters
are manufactured with glass sealed terminals
and connectors.
Filter Schematic A
LINE
Features
■
■
■
■
A
A
C
C
B
B
Filter Schematic B
LINE
LOAD
A
A
C
C
B
B
Dimensions
2.50
(63.50)
1.25
(31.75)
Insertion Loss
1.75
(44.45)
52-378-002, -004 MIL-STD-220
80
52-378-002
Insertion Loss (dB)
Military/Aerospace Multisection Filters
■
Excellent insertion loss profile
Available for DC & AC applications up to 400 Hz
Available for 3-14 Amp applications
Custom systems can be designed
to your specific needs
QPL to MIL-F 15733/63-0001
LOAD
1.500
(38.10)
.750
2.50
(19.05)
(63.50)
#8-32 UNC THD. INSERTS
(4.17-32)
.350 DEEP, 2 PLACES
(8.89)
CONNECTOR #8001-14S-7P-A3
MATES WITH MS-3106-14S-7S
60
40
20
0
0.01
0.1
1
10
Frequency (MHz)
100
1000
Dimensions in inches (mm)
102
Minimum Insertion Loss (db)
Model
Current
Rating
Voltage
Rating
Temperature
Range
DCR
max.
(ohms)
Leakage
Current
(max.)
Schematic
52-378-001
3 Amps
240VAC 60 Hz
Line to Line
-55°C to 85°C
.3
50 mA
A
30
60
70
80
80
70
70
52-378-002
5 Amps
240VAC 60 Hz
Line to Line
-55°C to 85°C
.2
50 mA
B
24
64
70
80
80
70
70
52-378-004
5 Amps
240VAC 60 Hz
Line to Line
-55°C to 85°C
.2
50 mA
A
34
64
70
80
80
70
70
52-378-005
3 Amps
240VAC 60 Hz
Line to Line
-55°C to 85°C
.3
50 mA
B
40
70
80
80
80
70
60
50 150 300
1
10 100
1
KHz KHz KHz MHz MHZ MHZ GHz
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power
Line Filters
Military/Aerospace
Multisection
Filters
for Secure Communications
Filter Schematic C
Insertion Loss
LINE
52-387-010, -003 MIL-STD-220
52-409-001 MIL-STD-220
LOAD
A
A
C
C
B
B
60
52-387-010,
-003 MIL-STD-220
40
Filter Schematic D
52-409-001
MIL-STD-220
20
0
0.01
0.1
1
10
Frequency (MHz)
LINE
100
LOAD
A
A
C
C
B
B
1000
Military/Aerospace Multisection Filters
Insertion Loss (dB)
80
Filter Schematic E
LINE
3 Phase and 400 Hz models available.
Please consult the factory.
LOAD
A
A
C
C
B
B
Dimensions
Figure 1
2.50
(63.50)
1.25
(31.75)
Figure 2
3.00
(76.20)
2.50
(63.50)
1.25
(31.75)
.625
(15.87)
#8-32 UNC
(4.17-32)
STUD
1.25
(31.75)
1.500
(38.10)
.750
2.50
(19.05)
(63.50)
1.500
(38.10)
.750
2.50
(19.05)
(63.50)
#8-32 UNC THD. INSERTS
(4.17-32)
.350 DEEP, 2 PLACES
(8.89)
Current
Rating
CONNECTOR #8001-10SL-3PN-FP-A3
MATES WITH MS-3106-10SL-3S
Voltage
Rating
Model
Fig.
52-387-010
1
10 Amps 240VAC 60 Hz
Line to Line
52-387-012
1
5 Amps
52-409-001
2
#8-32 UNC THD. INSERTS
(4.17-32)
.350 DEEP, 2 PLACES
(8.89)
Dimensions in inches (mm)
Temperature
Range
DCR Leakage
max. Current
(ohms) (max.)
common
24
60
70
80
80
70
70
common
34
64
70
80
80
70
70
differential
30
30
70
80
80
–
–
common
14
30
45
80
80
70
60
C
240VAC 400 Hz
-55°C to 85°C
Line to Line
.2
5 mA
D
50 mA
50 150 300 1.0
10 100
1
KHz KHz KHz MHz MHz MHz GHz
Mode
50 mA
.04
Dimensions in inches (mm)
Sch.
.2
-55°C to 85°C
CONNECTOR #8001-14S-7P-A3
MATES WITH MS-3106-14S-7S
Minimum Insertion Loss (db)
-55°C to 85°C
14 Amps 240VAC 60 Hz
Line to Line
1.75
(44.45)
E
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
103
Military/Aerospace
Multisection Filters
Secure Communications
Features
■
■
■
■
■
■
■
Meets applicable sections of MIL-F-15733
Excellent performance
Integral IEC connector
Available with integral fused IEC connector
and two pole switch
Current ratings to 15 Amps
Custom designs available
Designed to meet TEMPEST requirements
Part Numbering System:
760 - A
06
Q
Model
Military/Aerospace Multisection Filters
Current Rating:
3, 6, 10, 15 Amps
Electrical Specifications
Rated current ranges ..................
Rated voltage.............................
Operating frequency...................
Maximum leakage current
@115VAC 60 Hz............
@250VAC 50 Hz............
Test voltage
Line-to-Line ....................
Line-to-Ground...............
3, 6, 10, 15 Amps
115-250VAC
50-60 Hz
Terminal Style:
A=.25 Quick Connect
C=Wire Leads (4" min.)
1.2 mA
2.5 mA
Series: 760; 761 or 762
1450VDC
2250VDC
Insertion Loss
760, 761, 762 - 3, 6 Amps
760, 761, 762 - 10, 15 Amps
common mode
80
Insertion Loss (dB)
Insertion Loss (dB)
80
60
40
20
differential mode
0
0.01
0.1
1
10
Frequency (MHz)
100
1000
common mode
60
40
20
differential mode
0
0.01
0.1
1
10
Frequency (MHz)
100
1000
Common Mode (CM) is tested in a 50 ohm system with all lines tied together on the line and load sides of the filter.
Differential Mode (DM) is tested in a 50 ohm system using a 180˚ phase splitter on both sides of the filter.
104
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Military/Aerospace
Multisection Filters
Dimensions - 760 Series
.55 (13.97)
Current
Rating
(Amps)
Series
B
C
3, 6
2.25
(57.15)
3.00
(76.20)
1.88
(47.75)
10, 15
5.50
(139.70)
3.15
(88.01)
2.10
(53.34)
A
760
1.23
(31.24)
Filter Dimensions
A
.13 (3.30)
B
1.332
(33.83)
.67 (42.41)
C
.66 (16.67)
TERMINATION
STYLE “A”
8-32 Inserts (4 Places)
TERMINATION
STYLE “C”
Dimensions in inches (mm)
Dimensions - 761, 762 Series
C
Series
Current
Rating
(Amps)
761, 762
Filter Dimensions
A
B
C
3, 6
2.55
(64.77)
2.97
(75.43)
1.88
(47.75)
761
10, 15
5.50
(139.70)
3.15
(88.01)
2.10
(53.34)
762
10, 15
5.75
(146.05)
3.15
(88.01)
2.10
(53.34)
Military/Aerospace Multisection Filters
1.312
(33.32)
.95 (24.13)
3.00
(76.2)
0.20
(5.08)
1.30
(33.02)
1.30
(33.02)
0.20 (5.08)
A
0.80
(20.32)
1.875
(47.62)
6-32 UNC-2B
(6 Places)
B
3.67
(93.21)
0.80
(20.32)
.40 (10.16)
Switch Omitted
in Model 761
3, 6, 10, AMP
FRONT PANEL
Switch Omitted
in Model 761
15 AMP
FRONT PANEL
.55 (13.97)
Dimensions in inches (mm)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
105
Custom/Application
Specific Filters
SpectrumControl will address virtually any requirement for
a custom power product. Our many years of experience in
providing EMI/RFI solutions has allowed us to satisfy both
global EMC regulations and time-to-market constraints.
Spectrum Control’s engineering expertise and vertical
integration reduces your speed-to-market, as well as
saves you money.
Features/Benefits
■
■
■
■
■
■
■
■
■
Custom/Application Specific Filters
■
Incorporates filtering and custom circuitry into one
design package
SCI’s EMC Test Facility will define compliance issues
Current and voltage ratings to meet your specifications
Specific circuit designs to accommodate your application
Reduces your development time
Increases speed-to-market
Designed to perform in industrial environments
Designs incorporate filtering for both common and
differential modes
Ensures reliability (all parts are 100% tested)
Designed to meet agency approvals
Options
■
■
■
■
■
EMI filtering
Transient protection
Circuit breaker protection
Voltage cut-off
Reverse polarity
■
■
■
■
Power distribution
Indicator lights
Leads or studs
Agency approvals
Performance Characteristics
Insertion loss range
Effective filtering from 10 KHz to
10 MHz with proper installation
Current ratings (max.)
up to 500 Amps
Voltage ratings (max.)
400VDC and 240VAC standard,
custom ratings available
Leakage current ratings Varies, low leakage designs
available
Temperature
-25° C to +85° C
Specify your required current rating, voltage ratings
and capacitance value.
106
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
EMI Filtering
Custom/Application
Specific Filters
Circuit
Breaker
Protection
Power
Distribution
Multiple
Outlets
Power Distribution
Power Entry
EMI Filtering
Transient Protection
-48 VDC
-60 VDC
Rugged
Construction
Pigtail Leads
Low Voltage Cut-off
UL Recognized
Complies to UL 1459
CSA Certified
Custom/Application Specific Filters
Three-Phase Delta EMI Filter
High Current
Terminal Block
Custom Ground Plate
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
107
Custom/Application
Specific Filters
Spectrum Control's design teams can help transform
a functional electronic design into an easy to install
EMI filtered package containing all required components.
We will define your EMC problem through our test
facilities, develop a filter solution and manufacture
product to meet your schedule.
By designing and manufacturing
your entire assembly,
Spectrum Control will:
■
■
■
■
■
Custom/Application Specific Filters
■
Reduce development time
Combine your design into a compact, filtered package
Simplify installation, saving time and money
Increase productivity
Complement your inventory control program
Reduce your vendor base
108
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Custom/Application
Specific Filters
Single Line Filters
Power Distribution Units
Filtered
Terminal Blocks
PSM High Current
Surface Mount Filters
Custom/Application Specific Filters
Power
Line Filters
Remote control options available with intelligent power
distribution units.
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
109
Appendix
Part Number Index
110
Spectrum part # . . . . . . . . . . .Page
Spectrum part # . . . . . . . . . . .Page
Spectrum part # . . . . . . . . . . .Page
10-BPF-XXX-2-X . . . . . . . . . . . . . .32
10-BPF-XXX-5-X . . . . . . . . . . . . . .30
10-BPL-XXX-5-X . . . . . . . . . . . . . .38
11-MPC-XXX-X-X . . . . . . . . . . . . .58
12-MMB-XXX-5-X . . . . . . . . . . . . .82
12-MMB-XXX-5-X . . . . . . . . . . . . .86
12-MMB-XXX-11-X . . . . . . . . . . . .84
12-MMF-XXX-5-X . . . . . . . . . . . . .82
12-MMF-XXX-5-X . . . . . . . . . . . . .86
12-MMF-XXX-11-X . . . . . . . . . . . .84
12-PMB-XXX-DC-X . . . . . . . . . . . .78
12-PMB-XXX-X-X . . . . . . . . . . . . .76
12-PMF-XXX-DC-X . . . . . . . . . . . .78
12-PMF-XXX-2-X . . . . . . . . . . . . .66
12-PMF-XXX-5-X . . . . . . . . . . . . .72
12-PML-XXX-X-X . . . . . . . . . . . . .66
13-PDB-XXX-XX-X . . . . . . . . . . . .92
13-PDB-XXX-XX-X . . . . . . . . . . . .96
13-PDF-XXX-XX-X . . . . . . . . . . . .92
13-PDL-XXX-XX-X . . . . . . . . . . . .92
13-PWB-XXX-XX-A . . . . . . . . . . . .94
13-PWB-XXX-XX-B . . . . . . . . . . . .94
13-PWB-XXX-XX-C . . . . . . . . . . . .94
13-PWB-XXX-14-D . . . . . . . . . . . .94
13-PWB-XXX-XX-E . . . . . . . . . . . .94
13-PWB-010-12-D . . . . . . . . . . . . .90
13-PWB-015-12-D . . . . . . . . . . . . .90
13-PWB-020-12-D . . . . . . . . . . . . .90
13-PWB-025-12-D . . . . . . . . . . . . .90
13-PWB-030-12-D . . . . . . . . . . . . .90
13-PWF-XXX-XX-X . . . . . . . . . . . .90
13-PWL-XXX-XX-X . . . . . . . . . . . .90
52-226-001 . . . . . . . . . . . . . . . . . .20
52-226-002 . . . . . . . . . . . . . . . . . .20
52-226-004 . . . . . . . . . . . . . . . . . .20
52-226-006 . . . . . . . . . . . . . . . . . .20
52-226-008 . . . . . . . . . . . . . . . . . .20
52-226-009 . . . . . . . . . . . . . . . . . .20
52-226-011-XX . . . . . . . . . . . . . . .12
52-226-015 . . . . . . . . . . . . . . . . . .20
52-226-016-XX . . . . . . . . . . . . . . .16
52-226-019-XX . . . . . . . . . . . . . . .18
52-226-020-XX . . . . . . . . . . . . . . .14
52-226-021-XX . . . . . . . . . . . . . . .12
52-226-026-XX . . . . . . . . . . . . . . .16
52-226-029-XX . . . . . . . . . . . . . . .14
52-226-031-XX . . . . . . . . . . . . . . .12
52-226-036-XX . . . . . . . . . . . . . . .16
52-226-037-XX . . . . . . . . . . . . . . .18
52-226-041-XX . . . . . . . . . . . . . . .12
52-226-046-XX . . . . . . . . . . . . . . .16
52-267-002 . . . . . . . . . . . . . . . . . .20
52-267-003 . . . . . . . . . . . . . . . . . .20
52-267-008 . . . . . . . . . . . . . . . . . .20
52-267-009 . . . . . . . . . . . . . . . . . .20
52-267-010 . . . . . . . . . . . . . . . . . .20
52-267-011 . . . . . . . . . . . . . . . . . .20
52-267-012 . . . . . . . . . . . . . . . . . .20
52-378-XXX . . . . . . . . . . . . . . . .102
52-387-XXX . . . . . . . . . . . . . . . .103
52-409-XXX . . . . . . . . . . . . . . . .103
52-523-002 . . . . . . . . . . . . . . . . .100
52-600-XXX . . . . . . . . . . . . . . . . .99
52-1013-XXX . . . . . . . . . . . . . . . .23
60-BHP-XXX-X-X . . . . . . . . . . . . .56
60-BHS-XXX-X-X . . . . . . . . . . . . .28
60-BPF-XXX-X-X . . . . . . . . . . . . .26
60-BPL-XXX-X-X . . . . . . . . . . . . . .36
60-BPP-XXX-X-X . . . . . . . . . . . . .54
60-BPR-XXX-X-X . . . . . . . . . . . . .24
60-BPS-XXX-X-X . . . . . . . . . . . . .24
60-SPL-XXX-X-X . . . . . . . . . . . . . .34
60-SPR-XXX-X-X . . . . . . . . . . . . .40
60-SPS-XXX-X-X . . . . . . . . . . . . .40
61-MPC-XXX-X-XX . . . . . . . . . . . .52
62-AFC-XXX-X-XX . . . . . . . . . . . .60
62-AFL-XXX-X-XX . . . . . . . . . . . . .60
62-LMF-XXX-X-XX . . . . . . . . . . . .68
62-LMB-XXX-X-XX . . . . . . . . . . . .68
62-MMF-XXX-X-XX . . . . . . . . . . . .80
62-PMB-XXX-5-XX . . . . . . . . . . . .70
62-PMB-XXX-6-XX . . . . . . . . . . . .88
62-PMB-XXX-X-XX . . . . . . . . . . . .74
62-PMF-XXX-5-XX . . . . . . . . . . . .70
62-PML-XXX-X-XX . . . . . . . . . . . .64
62-PPF-XXX-X-XX . . . . . . . . . . . .62
62-PQF-XXX-X-XX . . . . . . . . . . . .62
62-PRF-XXX-X-XX . . . . . . . . . . . .62
63-PMF-XXX-8-XX . . . . . . . . . . . .88
63-PMF-XXX-9-XX . . . . . . . . . . . .88
64-BFF-XXX-X-X . . . . . . . . . . . . . .42
64-BFS-XXX-X-X . . . . . . . . . . . . .42
64-BSF-XXX-X-XX . . . . . . . . . . . .46
64-SSF-XXX-X-XX . . . . . . . . . . . .46
65-BFF-XXX-X-X . . . . . . . . . . . . . .42
65-BFS-XXX-X-X . . . . . . . . . . . . .42
65-BSF-XXX-X-XX . . . . . . . . . . . .46
65-SSF-XXX-X-XX . . . . . . . . . . . .46
66-BFF-XXX-X-X . . . . . . . . . . . . . .44
66-BFS-XXX-X-X . . . . . . . . . . . . .44
66-BFS-XXX-X-X . . . . . . . . . . . . .44
66-BSF-XXX-X-XX . . . . . . . . . . . .48
66-SSF-XXX-X-XX . . . . . . . . . . . .48
67-BFF-XXX-X-X . . . . . . . . . . . . . .44
67-BFS-XXX-XX . . . . . . . . . . . . . .44
67-BSF-XXX-X-X . . . . . . . . . . . . .48
67-SSF-XXX-X-X . . . . . . . . . . . . .48
68-BSF-XXX-X-XX . . . . . . . . . . . .50
760-XXXX . . . . . . . . . . . . . . . . . .106
761-XXXX . . . . . . . . . . . . . . . . . .106
762-XXXX . . . . . . . . . . . . . . . . . .106
1212-0502 . . . . . . . . . . . . . . . . . .101
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Appendix
Notes
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
111
Appendix
Notes
112
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Design Inquiry Form
Request for Quote/Custom Design Form
Outlet/Inlet Type:
Duplex
Single
IEC
Vendor
P/N
Company name
Other
Name/Title
AC
Requirements:
Address
City
Phone (
State
)
Fax (
120VAC
Other
Zip
)
Frequency
(Hz):
Target price
Anticipated yearly usage
Current
(Amps):
Life of program
250VAC
50
400
60
Other
Current/ phase (Amps):
Phase requirements:
Single
Customer Time Line (fill in dates):
Three
Quotation
Delta (3 wires)
Prototype
Wye (4 wires)
First Article
Other
Production Start Up
Leakage
Current:
Product Offering Suggested for this Application:
(Check appropriate response)
DC
Requirements:
Custom Assembly (Multi-Section Filter)
mA (max.)
Voltage:
Current (Amps):
Custom Assembly (Power Distribution Unit)
Insertion Loss
Requirements:
Power Entry Filter
Common mode (load) (no load)
Differential mode (no load)
High Current Single/Dual Line Filter
Accessories
Physical Parameters
Mechanical Requirements:
Surge
Suppression:
Maximum Dimensions:
Height (inches)
Length (inches)
No
Yes
Define
Width
Please include drawing or sketch, if available.
Circuit
Breaker:
Electrical Parameters
No
Current Rating
LOAD SIDE
Vendor
P/N
Lighted
Non-lighted
Remote
None
UL
CE
CSA
TUV
Connector
Studs
Switches:
Pigtails/leads
Connector
Terminal
Block
Agency
Approvals:
Appendix
Voltage Rating
Electrical Terminations:
LINE SIDE
Yes
Other
Other
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
113
A
Control Products
Systems Company
&
As A Control Products & Systems Company, we
strive to meet our customers’ needs by providing greater
component and system solutions to their design problems.
Our family of interference, power and microwave products
is now the broadest line in the industry. These engineering
driven products deliver unmatched performance in the
high frequencies common to new applications.
To satisfy the increased demand that corresponds
with our growth, we’ve conducted a major manufacturing
expansion. This additional manufacturing capacity involves
all of our facilities and is highlighted by our new plants in
Juarez, Mexico and Guang Dong, China. These expanded
facilities produce components and systems for all of our
groups and have received numerous positive customer audits.
Global
Manufacturing
Signal & Power Integrity Group
As a vertically integrated producer of ceramic capacitors
and filters, we continue to provide the widest range of
discrete EMI filters, filtered connectors, ferrite inductors
and filtered power products. In addition, we have
extended our ceramic technology to develop our
line of wireless components.
■ Low Pass EMI Filters
■ Ceramic Capacitors
■ Filtered Terminal Blocks
■ Single Line Filters
and Filter Plates
■ Filtered Terminal Blocks
■ Filtered Connectors
■ Power Entry Modules
■ Datacom Connectors
and Power Line Filters
■ Ferrite Inductors
■ Multisection Filters
EMI Filters
and Filtered
Power
Products
Frequency Control Group
In order to expand our line of microwave products,
we recently acquired FSY Microwave, including all
products and design expertise. The new Spectrum
FSY Microwave family of SPECWAVE components
and systems provides a wide range of frequency
control solutions.
■ Bandpass Filters
■ Suspended Substrates
and Duplexers
■ Cavity Filters
■ Patch Antenna
■ Coaxial Tubular Filters
Elements
■ Microwave Custom
■ Waveguide Filters
Assemblies
■ Lumped Element Filters
Frequency
Control
Products
Power Management Systems Group
Several years ago, we began to apply our
fundamental filtering expertise to improve power
management. The result is a complete line of
standard, yet customizable power distribution
units and remote management systems.
■ SMARTstart AC/DC Intelligent
Power Distribution Units
■ SHARPstart AC/DC Power Distribution Units
■ Custom Commercial Assemblies
114
Power
Management
Systems
CERTIFIED
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Our new Check Stock system allows you to gather instant
information regarding a particular component’s inventory
status at Spectrum Control’s network of authorized distributors.
Selecting the Check Stock icon will provide you with distributor
names, part numbers, quantity on hand, online ordering
capability and the last date the inventory was updated for
that particular component. Use Check Stock to improve your
organization’s efficiency by simplifying inventory management
and reducing inventory
We’ve made finding the right product for your application
easier than ever. By using our new online catalog you can tell
us the performance parameters you need and we’ll help you
locate the appropriate product. You start by identifying your
mechanical package, add some required electrical characteristics
and we’ll show you applicable standard part numbers and how
they compare to your specifications.
New Design Direct allows you to work with our engineers in a
collaborative online effort to develop a custom solution tailored
to your specific needs. After registering on our site, you’ll be
able to create and track your project, entirely online. As our
engineering team makes changes to your project, you’ll receive
an e-mail with a direct link to see the current status and provide
feedback. Designing a custom solution has never been easier.
To see all of our new online tools,
come visit us @ www.spectrumcontrol.com
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
115
A
Control Products
Systems Company
&
Signal & Power
Integrity Products
Ferrite beads & inductors
Surface mount filters
Discrete EMI filters
Filter plates
Filter connectors
Gaskets & shielding
Ceramic capacitors
Single line filters
Filtered terminal blocks
Power entry & power line filters
Military/multisection filters
EMC testing
www.spectrumcontrol.com
Corporate Headquarters
8031 Avonia Road
Fairview, Pennsylvania 16415
Phone: 814-474-2207
Fax:
814-474-2208 NEW
Signal & Power Integrity
8061 Avonia Road
Fairview, Pennsylvania 16415
Phone: 814-474-1571
Fax:
814-474-3110
Sales Offices
NORTH AMERICA
NEW
6798 Oak Hall Lane
Columbia, Maryland 21045
Phone: 301-916-2919
Fax:
301-916-2910
EUROPE
Spectrum Control GmbH
Hansastrasse 6
91126 Schwabach, Germany
Phone: (49)-9122-795-0
Fax:
(49)-9122-795-58
Frequency Control Products
Resonators
Bandpass filters & duplexers
Patch antenna elements
Waveguide filters
Combiners
Couplers
Duplexer-LNA assemblies
Lumped element filters
Suspended Substrates
Cavity filters
Coaxial tubular filters
Microwave custom assemblies
Tower mount amplifiers
www.specwave.com
Represented or Distributed by:
Power Management Systems
AC/DC power distribution units
& remote reboot power management systems
Custom assemblies
Power strips
www.specpower.com
AHA
12/03
20M
27-0027-0046
CHINA
Spectrum Control Limited
Room 73-78 - 2nd Floor
Sino Industrial Plaza
NEW
9 Kai Cheung Road
Kowloon Bay
Kowloon, Hong Kong
Phone: (011)-852-2197-9912
Fax:
(011)-852-2750-9663
For additional information regarding
Spectrum Control, our full line of
EMI filtering and power products
and our many new products,
call us or contact our Website at
http://www.spectrumcontrol.com
Spectrum Control, Inc. reserves
the right to alter the specifications
provided in this publication.
Consult factory for current
specifications.
CERTIFIED
© Spectrum Control, Inc.
Printed in U.S.A.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
API Technologies:
1212-0502
Download