watteredge.com ISOLATOR/DISCONNECT SWITCH—TYPE DCS But Contact Design, Bolted Bus, 6kA to 72kA The Watteredge But Contact Type High current disconnect switch is an OFF-Load switch that utilizes a proprietary sealed silver contact assembly. This switch design is available in single and back to back configurations for both AC and DC plant installations. The switch is self supporting and can be installed in aluminum or copper bus systems without additional support. The disconnect is supported by the bus bar system. An integrated flexible terminal allows for the switch operation and also can be used to compensate for thermal expansion in the bus bar system. Features: x x x x x x Mounting: all mounting orientations possible DC or AC applications Working voltage up to 1000V Manual, Electric or Pneumatic drive Electromechanical interlock, Kirk key interlock Auxiliary limit switches DC Disconnect Type DCS-S-12-P 12kA with pneumatic Actuator and solenoid valve. Options/Accessories: x x x x x RTD temperature monitoring Voltage monitoring Pre-arcing contacts for back EMF Control box Pneumatic protection systems Applications: x x x Single pole Multiple pole Change over (Polarity reversing) DC Disconnect Type DCS-S-30-E 30kA with electric Actuator © 2014 Watteredge LLC • 567 Miller Road • Avon Lake, Ohio 44012-2304 USA • Phone: (440) 933-6110 • Toll Free: (800) 311-8515 • Fax: (440) 933-8248 2 3 Flohe DC High current isolator The modular structure corresponds to the highest mechanical and electrical standards. TYPE FRH Type FRH has a visible isolating distance and regardless of the position, can be vertically or horizontally welded or screwed into the busbar system. DC High current isolator FRH 5 kA · 400 kA · single-doublepole The isolator has incoming and outgoing aluminium contact blocks or copper contact blocks which are provided for welding or screwing to the existing busbar system. An additional wall support is not necessary. The isolator is supported by the busbar package. Shifts to the busbars are compensated in three directions. for currentless switching in DC systems VDE 0110 Group C · EN 60947-3 · IEC 60077-1 쑺 FRH-CC Copper bolted version A flexible spring adjustment system ensures a secure electrical and mechanical contact and the silver plated main contacts ensure a low voltage drop. FRH types can be supplied in all needed versions 쮿 Manual / 쮿 Locking systems: motor pneumatic 쮿 Remote drive / 쮿 emergency drive 쮿 Panic switch function 쮿 Auxiliary switch for inter- 쮿 nal and external control Type mechanical or electrical Terminal box: local / or remote control box Temperature monitoring Current Assembling Contact adapter A A1 A2 A3 쑺쑺쑺 Standard units max. nominal current max. nominal voltage Peak short circuit current Insulation voltage max. ambient temperature max. temperatur rise Operating time ON OFF Traversing in (x/y/z) direction mechanical lifespan 400 kA 3000 V 10x nominal current 1 s 5000 V DC 60°C max. ambient temp. +40°C motor less 20s/pneumatic less 1s ± 20 mm 5000 operations FRH-AA 1x15 1x20 1x25 1x30 1x35 1x40 1x45 1x50 1x55 1x60 1x70 1x80 1x90 1x100 1x110 1x120 2x65 2x70 2x75 2x80 2x90 2x100 180 230 280 330 380 430 480 530 580 630 730 830 930 1030 1130 1230 1470 1570 1670 1770 1970 2170 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 Dimension Contact adapter B B1 B2 B3 260 310 360 410 460 510 560 610 660 710 810 910 1010 1110 1210 1310 1550 1650 1750 1850 2050 2250 쮿 FRH‐CC Aluminium welded version 쑸쑸쑸 쮿 FRH‐AC Copper bolted version 쮿 FRH‐MO Combination Al/Cu Mobile for graphite plants Custom design upon request C D Type E B3 F B3 closed open B3 G B3 closed open H 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 167 167 167 167 167 167 167 167 167 167 167 167 167 167 167 167 167 167 167 167 167 167 400 450 500 550 600 650 700 750 800 850 950 1050 1150 1250 1350 1450 1690 1790 1890 1990 2190 2390 475 475 475 475 475 475 475 475 475 475 475 475 475 475 475 475 475 475 475 475 475 475 783 833 883 933 983 1033 1083 1133 1183 1233 1333 1433 1533 1633 1733 1833 2073 2173 2273 2373 2573 2773 226 226 226 226 226 226 226 226 226 226 226 226 226 226 226 226 226 226 226 226 226 226 Other designs upon request · E + G + H = external dimension · all engine-driven designs with manual panic switch function 326 326 326 326 326 326 326 326 326 326 326 326 326 326 326 326 326 326 326 326 326 326 559 559 559 559 559 559 559 559 559 559 559 559 559 559 559 559 559 559 559 559 559 559 646 646 646 646 646 646 646 646 646 646 646 646 646 646 646 646 646 646 646 646 646 646 Current Assembling Contact adapter A A1 A2 A3 617 617 617 617 617 617 617 617 617 617 617 617 617 617 617 617 617 617 617 617 617 617 Dimension Contact adapter B B1 B2 B3 C D E standard standard standard standard standard standard standard standard standard standard ON OFF ON OFF min. min. min. min. approx. approx. approx. [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] min. [kA] 15 20 25 30 35 40 45 50 55 60 70 80 90 100 110 120 130 140 150 160 180 200 쮿 FRH‐AA Techni cal data standard standard standard standard standard standard standard standard standard FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FLOHE DC High current Isolator FRH is universally as… 15 20 25 30 35 40 45 50 55 60 70 80 90 100 110 120 130 140 150 160 180 200 open B3 G B3 closed open H standard ON OFF ON OFF min. min. min. min. approx. approx. approx. [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] min. [kA] FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA B3 F B3 closed 1x 15 1x 20 1x 25 1x 30 1x 35 1x 40 1x 45 1x 50 1x 55 1x 60 1x 70 1x 80 1x 90 1x 100 1x 110 1x 120 2x 65 2x 70 2x 75 2x 80 2x 90 2x100 180 230 280 330 380 430 480 530 580 630 730 830 930 1030 1130 1230 1470 1570 1670 1770 1970 2170 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 260 310 360 410 460 510 560 610 660 710 810 910 1010 1110 1210 1310 1550 1650 1750 1850 2050 2250 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 400 450 500 550 600 650 700 750 800 850 950 1050 1150 1250 1350 1450 1690 1790 1890 1990 2190 2390 475 475 475 475 475 475 475 475 475 475 475 475 475 475 475 475 475 475 475 475 475 475 783 833 883 933 983 1033 1083 1133 1183 1233 1333 1433 1533 1633 1733 1833 2073 2173 2273 2373 2573 2773 226 226 226 226 226 226 226 226 226 226 226 226 226 226 226 226 226 226 226 226 226 226 Other designs upon request · E + G + H = external dimension · all engine-driven designs with manual panic switch function 326 326 326 326 326 326 326 326 326 326 326 326 326 326 326 326 326 326 326 326 326 326 559 559 559 559 559 559 559 559 559 559 559 559 559 559 559 559 559 559 559 559 559 559 646 646 646 646 646 646 646 646 646 646 646 646 646 646 646 646 646 646 646 646 646 646 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 2 3 Flohe DC High current isolator The modular structure corresponds to the highest mechanical and electrical standards. TYPE FRH Type FRH has a visible isolating distance and regardless of the position, can be vertically or horizontally welded or screwed into the busbar system. DC High current isolator FRH 5 kA · 400 kA · single-doublepole The isolator has incoming and outgoing aluminium contact blocks or copper contact blocks which are provided for welding or screwing to the existing busbar system. An additional wall support is not necessary. The isolator is supported by the busbar package. Shifts to the busbars are compensated in three directions. for currentless switching in DC systems VDE 0110 Group C · EN 60947-3 · IEC 60077-1 쑺 FRH-CC Copper bolted version A flexible spring adjustment system ensures a secure electrical and mechanical contact and the silver plated main contacts ensure a low voltage drop. FRH types can be supplied in all needed versions 쮿 Manual / 쮿 Locking systems: motor pneumatic 쮿 Remote drive / 쮿 emergency drive 쮿 Panic switch function 쮿 Auxiliary switch for inter- 쮿 nal and external control Type mechanical or electrical Terminal box: local / or remote control box Temperature monitoring Current Assembling Contact adapter A A1 A2 A3 쑺쑺쑺 Standard units max. nominal current max. nominal voltage Peak short circuit current Insulation voltage max. ambient temperature max. temperatur rise Operating time ON OFF Traversing in (x/y/z) direction mechanical lifespan 400 kA 3000 V 10x nominal current 1 s 5000 V DC 60°C max. ambient temp. +40°C motor less 20s/pneumatic less 1s ± 20 mm 5000 operations FRH-AA 1x15 1x20 1x25 1x30 1x35 1x40 1x45 1x50 1x55 1x60 1x70 1x80 1x90 1x100 1x110 1x120 2x65 2x70 2x75 2x80 2x90 2x100 180 230 280 330 380 430 480 530 580 630 730 830 930 1030 1130 1230 1470 1570 1670 1770 1970 2170 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 Dimension Contact adapter B B1 B2 B3 260 310 360 410 460 510 560 610 660 710 810 910 1010 1110 1210 1310 1550 1650 1750 1850 2050 2250 쮿 FRH‐CC Aluminium welded version 쑸쑸쑸 쮿 FRH‐AC Copper bolted version 쮿 FRH‐MO Combination Al/Cu Mobile for graphite plants Custom design upon request C D Type E B3 F B3 closed open B3 G B3 closed open H 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 167 167 167 167 167 167 167 167 167 167 167 167 167 167 167 167 167 167 167 167 167 167 400 450 500 550 600 650 700 750 800 850 950 1050 1150 1250 1350 1450 1690 1790 1890 1990 2190 2390 475 475 475 475 475 475 475 475 475 475 475 475 475 475 475 475 475 475 475 475 475 475 783 833 883 933 983 1033 1083 1133 1183 1233 1333 1433 1533 1633 1733 1833 2073 2173 2273 2373 2573 2773 226 226 226 226 226 226 226 226 226 226 226 226 226 226 226 226 226 226 226 226 226 226 Other designs upon request · E + G + H = external dimension · all engine-driven designs with manual panic switch function 326 326 326 326 326 326 326 326 326 326 326 326 326 326 326 326 326 326 326 326 326 326 559 559 559 559 559 559 559 559 559 559 559 559 559 559 559 559 559 559 559 559 559 559 646 646 646 646 646 646 646 646 646 646 646 646 646 646 646 646 646 646 646 646 646 646 Current Assembling Contact adapter A A1 A2 A3 617 617 617 617 617 617 617 617 617 617 617 617 617 617 617 617 617 617 617 617 617 617 Dimension Contact adapter B B1 B2 B3 C D E standard standard standard standard standard standard standard standard standard standard ON OFF ON OFF min. min. min. min. approx. approx. approx. [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] min. [kA] 15 20 25 30 35 40 45 50 55 60 70 80 90 100 110 120 130 140 150 160 180 200 쮿 FRH‐AA Techni cal data standard standard standard standard standard standard standard standard standard FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FRH-CC FLOHE DC High current Isolator FRH is universally as… 15 20 25 30 35 40 45 50 55 60 70 80 90 100 110 120 130 140 150 160 180 200 open B3 G B3 closed open H standard ON OFF ON OFF min. min. min. min. approx. approx. approx. [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] min. [kA] FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA FRH-AA B3 F B3 closed 1x 15 1x 20 1x 25 1x 30 1x 35 1x 40 1x 45 1x 50 1x 55 1x 60 1x 70 1x 80 1x 90 1x 100 1x 110 1x 120 2x 65 2x 70 2x 75 2x 80 2x 90 2x100 180 230 280 330 380 430 480 530 580 630 730 830 930 1030 1130 1230 1470 1570 1670 1770 1970 2170 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 260 310 360 410 460 510 560 610 660 710 810 910 1010 1110 1210 1310 1550 1650 1750 1850 2050 2250 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 400 450 500 550 600 650 700 750 800 850 950 1050 1150 1250 1350 1450 1690 1790 1890 1990 2190 2390 475 475 475 475 475 475 475 475 475 475 475 475 475 475 475 475 475 475 475 475 475 475 783 833 883 933 983 1033 1083 1133 1183 1233 1333 1433 1533 1633 1733 1833 2073 2173 2273 2373 2573 2773 226 226 226 226 226 226 226 226 226 226 226 226 226 226 226 226 226 226 226 226 226 226 Other designs upon request · E + G + H = external dimension · all engine-driven designs with manual panic switch function 326 326 326 326 326 326 326 326 326 326 326 326 326 326 326 326 326 326 326 326 326 326 559 559 559 559 559 559 559 559 559 559 559 559 559 559 559 559 559 559 559 559 559 559 646 646 646 646 646 646 646 646 646 646 646 646 646 646 646 646 646 646 646 646 646 646 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600