Buell® Blast Tech Note

advertisement
Twin Tec
Buell Blast Tech Note
CAUTION: CAREFULLY READ INSTRUCTIONS BEFORE PROCEEDING. NOT LEGAL FOR SALE
OR USE IN CALIFORNIA OR ON ANY POLLUTION CONTROLLED VEHICLES.
OVERVIEW
The Model 1005 ignition module can be used on
single cylinder Buell® Blast models with minor
modifications as described in this tech note.
REQUIRED PARTS
You will require the following parts:
1. Twin Tec Model 1005 ignition module P/N 1005
2. Twin Tec 3 ohm mini coil P/N MINI-COIL
2. The timing cover has a boss that must be relieved
to provide clearance for the Model 1005 ignition
module as shown in Figure 2. Final orientation of
the ignition module is shown in Figure 3. Remove
the minimum amount of material so that the ignition
module may be rotated freely from end-to-end of
the slots once the mounting standoffs are installed.
Caution: if you remove too much material, oil
leakage may occur.
Figure 2 – Timing Cover Modification
3. H-D timing rotor P/N 32402-83 or an equivalent
aftermarket part such as Twin Tec P/N ROTOR32402
4. VOES switch (highly recommended for all
applications except drag racing) such as Twin Tec
P/N VOES-KIT-MC7.
INSTALLATION
1. The timing rotor requires a modification as shown
in Figure 1 below. Flatten or grind off the existing
index notch. Punch a new index notch oriented 45
degrees counterclockwise from the original notch.
Figure 1 – Timing Rotor Modification
Figure 3 – Ignition Module Orientation
Daytona Twin Tec LLC, 933 Beville Road, Suite 101-H, S. Daytona, FL 32119
(386) 304-0700 www.daytona-twintec.com
Page 1
Buell® Blast Tech Note
5/2015
3. Follow the Model 1005 installation instructions,
except use the wiring diagram shown in Figure 4.
The unit must be operated in single fire mode.
Note that the blue wire is used for the coil
connection. The unused pink wire should be taped
up.
Figure 4 – Buell® Blast Wiring Diagram
ENGINE
STOP/RUN
SWITCH
TO
+12V
TWIN TEC 3 OHM MINI COIL
TO FRONT
SPARK
PLUG
BLUE
OPTIONAL VOES
(VACUUM SWITCH)
WHITE/BLACK
PURPLE/WHITE
TAPE UP WIRE IF
VOES NOT USED
OPTIONAL TACH
ADJUST
MODE ADVANCE RPM LIMIT
SELECT SLOPE X1000 X100
901
901
78
901
78
78
901
23
456
23
456
23
456
456
23
78
STATUS
WEATHER PACK CONNECTORS
FEMALE TERMINAL MALE TERMINAL
VOES
TwinTec
Internal Ignition
Model 1005
RPM
BROWN
MODE SETTINGS FOR SINGLE FIRE
2 STREET ADVANCE CURVES, MULTI-SPARK DISABLED
3 STREET ADVANCE CURVES, MULTI-SPARK ENABLED
6 RACE ADVANCE CURVES, MULTI-SPARK DISABLED
7 RACE ADVANCE CURVES, MULTI-SPARK ENABLED
TIMING PROCEDURE
The Buell® Blast engine has a straight line as
the TDC timing mark. You can follow the same static
timing procedure as explained in the Model 1005
instructions. For precise timing or checking custom
advance curves, use a dial-back timing light referenced
back to the TDC timing mark. All standard dial-back
TO PC
SERIAL
PORT
OPTIONAL CABLE CONNECTED TO
BROWN TACH WIRE DURING PC LINK
timing lights should work properly with this single
cylinder application. Make sure you disable multi-spark
when using the timing light.
Daytona Twin Tec LLC, 933 Beville Road, Suite 101-H, S. Daytona, FL 32119
(386) 304-0700 www.daytona-twintec.com
Page 2
Buell® Blast Tech Note
5/2015
Download