PANZONE Wall Mount Cabinet Part Numbers: PZC12S, PZC12P, PZC12W INSTRUCTIONS CM315 © Panduit Corp. 2006 PZC12S Cabinet with Solid Door PZC12P Cabinet with Perforated Door Location Footprint PZC12W Cabinet with Windowed Door Cabinet depth is 22.9” in closed position 43.0" Footprint with Cabinet Open 25.0" Cabinet Width 6.5" 16.0" Mounting Holes 2.3" 25.6" 19.7" Mouunting Holes FOR TECHNICAL SUPPORT www.panduit.com/resources/install_maintain.asp Page 1 of 4 INSTRUCTIONS CM315 PANZONE Wall Mount Cabinets can be installed in a hinged right or hinged left application. For your installation, determine which side of the cabinet will hinge. The cabinet is shown hinged right. Rotate the cabinet 180 degrees for the left hinge application. Mounting surface must have sufficient strength to support the cabinet with payload. The mounting surface must also be flat and extend beyond the overall cabinet footprint. 7/8” Conduit Knockout 2” or 3” Conduit Knockout Wireless Access Point Knockouts 2” Conduit Knockout Step 1: Install (4) 3/8” mounting hardware (not provided) as shown in Location Footprint. Hardware should protrude 3/8” from wall. Mount the cabinet to the wall by hooking the keyholes over the protruding 3/8” mounting hardware. Once the cabinet is in place, carefully swing cabinet from wall and tighten the hardware securely. Front Door with Lock 7/8” or 1 1/8” Conduit Knockout Step 2: Install door by pressing(2) hinges provided in locations shown below. Step 3:To adjust the depth of the mounting rail for specific applications, remove the mounting screws and lockwashers, move the rail to the desired position and re-install mounting hardware. Mounting Rail Door Hinges Mounting Hardware For Technical Support: www.panduit.com/resources/install_maintain.asp Page 2 of 4 INSTRUCTIONS CM315 Cable Routing Cable must be routed with an adequate slack loop to prevent cable damage. Route cable to point 1 secure to tie down with a TAC-TY. Next route cable across the bottom of the enclosure to point 2 secure to tie down with a TAC-TY. Route to the desired patch panel after securing the cables with a Tac-Ty at point 3 or 4. Point 4 Point 1 Point 3 Cables Extend to Patch Panel Point 2 For Technical Support: www.panduit.com/resources/install_maintain.asp Page 3 of 4 INSTRUCTIONS CM315 PZC12S Cabinet with Solid Door PZC12P Cabinet with Perforated Door PZC12W (Shown) Cabinet with Window Door Optional Accessories PZBR4 PANZONE 4” Bend Radius Post Kit PZCFK PANZONE Fan Kit PZCHSM2 PANZONE Horizontal Slack Manager PZCRR PANZONE Rear Equipment Rail Kit For instuctions in Local Languages and Technical Support: www.panduit.com/resources/install_maintain.asp www.panduit.com Page 4 of 4 E-mail: cs@panduit.com Fax: (708)444-6448