G9EC-1 DC Power Relays (200-A Models) DC Power Relays Capable of Interrupting High-voltage, High-current Loads • A compact relay (98 x 44 x 86.7 mm (L x W x H)) capable of switching 400-V 200-A DC loads. (Capable of interrupting 1,000 A at 400 VDC max.) • The switching section and driving section are gas-injected and hermetically sealed, allowing these compact relays to interrupt high-capacity loads. The sealed construction also requires no arc space, saves space, and helps ensure safe applications. • Downsizing and optimum design allow no restrictions on the mounting direction. • Terminal Cover is also available for industrial applications. • UL/CSA standard UL508 approved. RoHS Compliant Refer to "DC Power Relays Common Precautions". ■Model Number Legend G 9 E C -@ -@ -@ -@ — — — — 2 3 4 2. Contact Form Blank: SPST-NO - 1 1. Number of Poles 1: 1 pole G 9 E C 1 3. Coil Terminals B : M3.5 screw terminals (standard) Blank: Lead wire output 4. Special Functions ■List of Models Terminals Models Coil terminals Contact terminals Contact form Coil rated voltage SPST-NO 12 VDC 24 VDC 48 VDC 60 VDC 100 VDC Screw terminals Switching/current conduction models Screw terminals Lead wire Model G9EC-1-B G9EC-1 Note 1. Two M8 nuts are provided for the contact terminal connection. Note 2. Two M3.5 screws are provided for the coil terminal connection. ■Ratings ●Coil Item Rated voltage Rated current (mA) Coil resistance (Ω) 12 VDC 938 24 VDC 469 51.2 48 VDC 234 204.8 60 VDC 188 320.0 100 VDC 113 888.9 Must-operate voltage Must-release voltage (V) (V) Maximum voltage (V) Power consumption (W) 110% of rated voltage (at 23°C within 10 minutes) Approx. 11 12.8 75% max. of rated voltage 8% min. of rated voltage Note 1. The figures for the rated current and coil resistance are for a coil temperature of 23°C and have a tolerance of ±10%. Note 2. The figures for the operating characteristics are for a coil temperature of 23°C. Note 3. The figure for the maximum voltage is the maximum voltage that can be applied to the relay coil. ●Contacts Item Rated load Resistive load G9EC-1(-B) 200 A at 400 VDC Rated carry current 200 A Maximum switching voltage 400 V Maximum switching current 200 A 1 G9EC-1 DC Power Relays (200-A Models) ■Characteristics Item Model Contact resistance *1 Contact voltage drop 0.1 V max. (for a carry current of 200 A) Operate time 50 ms max. Release time Insulation resistance *2 Dielectric strength 30 ms max. Between coil and contacts 1,000 MΩ min. Between contacts of the same polarity 1,000 MΩ min. Between coil and contacts 2,500 VAC, 1 min Between contacts of the same polarity 2,500 VAC, 1 min Impulse withstand voltage *3 Vibration resistance Shock resistance 4,500 V Destruction 10 to 55 to 10 Hz 0.75-mm single amplitude (Acceleration: 2.94 to 88.9 m/s2) Malfunction 10 to 55 to 10 Hz 0.75-mm single amplitude (Acceleration: 2.94 to 88.9 m/s2) Destruction 490 m/s2 Malfunction 196 m/s2 Mechanical endurance *4 - G 9 E C 1 G9EC-1(-B) 30 mΩ max. (0.2 mΩ typical) 200,000 operations min. Electrical endurance (resistive load) *5 400 VDC, 200 A, 3,000 operations min. Short-time carry current 300 A (15 min) Maximum interruption current 1,000 A at 400 VDC (10 times) Overload interruption 700 A at 400 VDC (40 times min.) Reverse polarity interruption -200 A at 200 VDC (1,000 times min.) Ambient operating temperature -40 to 50°C (with no icing or condensation) Ambient operating humidity 5% to 85% Weight (Including accessories) Approx. 560 g Note. The above values are initial values at an ambient temperature of 23°C unless otherwise specified. *1. The contact resistance was measured with 1 A at 5 VDC using the voltage drop method. *2. The insulation resistance was measured with a 500-VDC megohmmeter. *3. The impulse withstand voltage was measured with a JEC-212 (1981) standard impulse voltage waveform (1.2 x 50 μs). *4. The mechanical endurance was measured at a switching frequency of 3,600 operations/hr. *5. The electrical endurance was measured at a switching frequency of 60 operations/hr. 2 G9EC-1 DC Power Relays (200-A Models) ■Engineering Data Operations (× 104 1,000 500 300 100 DC resistive load 50 30 10 5 3 10 5 Switching 400-VDC resistive load (positive direction) 3 1,000 500 300 1 100 0.5 50 0.3 30 0.1 10 1 0.05 5 0.5 0.3 0.03 3 0.1 30 50 100 300 ●Carry Current vs Energizing Time 10 30 50 100 10,000 300 10 500 1,000 50 100 ●Must-operate Voltage and Must-release Voltage Distributions 1,000 30 Sample: G9EC-1 Number: 35 Must-operate voltage Must-release voltage 25 20 500 1,000 10,000 Switching current (A) Switching current (A) Number of Relays 100,000 Interrupting 400-VDC resistive load (positive direction) 1 0.01 500 1,000 Switching voltage (V) ●Time Characteristic Distributions Number of contacts 10 Energizing time (s) ●Electrical Endurance (Interruption Performance) Operations 卐 Switching current (A) G9EC-1(-B) Switching/Current Conduction Models ●Maximum Switching Capacity ●Electrical Endurance (Switching Performance) 30 Sample: G9EC-1 Number: 32 Operate time Release time 25 20 15 15 10 10 5 5 G 9 E C 1 100 - 10 100 300 500 0 700 1,000 10 20 Sample: G9EC-1 Number: 5 Unconfirmed area 0.8 0.7 5.0 4.0 60 70 80 0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 Time (ms) Sample: G9EC-1 Number: 5 3.0 2.0 0.6 1.0 0.5 0.0 Must-release voltage Must-operate voltage Confirmed area 0.4 50 ●Vibration Resistance Rate of change (%) Single amplitude (mm) 1 0.9 40 Percentage of rated voltage (%) Carry current (A) ●Vibration Malfunction 30 -1.0 0.3 -2.0 0.2 -3.0 0.1 -4.0 -5.0 0 1 3 5 10 30 50 100 Start After test Characteristics were measured after applying vibration at a frequency of 10 to 55 Hz (single amplitude of 0.75 mm) to the test piece (not energized) for 2 hours each in 3 directions. The percentage rate of change is the average value for all of the samples. Frequency (Hz) Unit: m/s2 Sample: G9EC-1 Number: 5 ●Shock Resistance T: TAC VDC -1-BCONA 400 ECC 200 AN 1 G9VDJAP -000 12 IN 2K1 136 1,000 E MAD Lot Z No. X 800 Y' Y 600 X Z' ) 1(+ ) 2(- Y Z X' Rate of change (%) ●Shock Malfunction 5.0 4.0 Sample: G9EC-1 Number: 5 3.0 2.0 400 1.0 200 0.0 Must-operate voltage Must-release voltage 㸫1.0 200 Z' Deenergized 㸫2.0 400 X' 600 㸫4.0 800 1,000 Y' 㸫3.0 Energized The value at which malfunction occurred was measured after applying shock to the test piece 3 times each in 6 directions along 3 axes. 㸫5.0 Start After test Characteristics were measured after applying a shock of 490 m2/s to the test piece 3 times each in 6 directions along 3 axes. The percentage rate of change is the average value for all of the samples. 3 G9EC-1 DC Power Relays (200-A Models) ■Dimensions (Unit: mm) ●Models with Screw Terminals G9EC-1-B Terminal Arrangement/ Internal Connections (TOP VIEW) 1 (+) 7 32 44 2-M3.5 2 (−) 1 (+) 2 : CT DC TA 0V BN 0 -1- C0O0A 4 EC 2 G9VDJACPAN 01 -00 K1 1A2DE IN 62 13 M tN 7 28.6 ) 2(− o. Lo 98 Mounting Hole Dimensions (TOP VIEW) 2-M8 26 1(+) 86.7 68.6 (Terminal height) G9EC-1-B 12VDC CONTACT: 200A 400VDC 8 MADE IN JAPAN 44.2 (Coil terminal height) Dimension (mm) Tolerance (mm) 10 or lower ±0.3 10 to 50 ±0.5 50 or higher ±1 Two, M6 or 6.5-dia. holes 26.7 2(−) 7 8 Note: Be sure to connect terminals with the correct polarity. Coils do not have polarity. 72 86 Two, 6.2-dia. holes 86±0.1 Lot No. 1362K1-0001 10.5 32±0.1 ●Models with Lead Wires G G9EC-1 9 E C 1 Terminal Arrangement/ Internal Connections (TOP VIEW) 1 (+) 32 44 - 2 (−) ) 1(+ 2 ) 2(− M tN 7 28.6 : CT DC TA 0V BN 0 -1- C0O0A 4 EC 2 G9VDJACPAN 01 -00 K1 1A2DE IN 62 13 o. Lo 98 26 (10) 2-M8 230±20 Two, M6 or 6.5-dia. holes 1(+) G9EC-1 12VDC 8 Mounting Hole Dimensions (TOP VIEW) 26.7 2(−) 7 8 Note: Be sure to connect terminals with the correct polarity. Coils do not have polarity. 72 86 Two, 6.2-dia. holes MADE IN JAPAN 86.7 68.6 (Terminal height) CONTACT: 200A 400VDC 86±0.1 Lot No. 1362K1-0001 Dimension (mm) Tolerance (mm) 10 or lower ±0.3 10 to 50 ±0.5 50 or higher ±1 10.5 32±0.1 ■Options (Unit: mm) ●Terminal Cover P9EC-C * Dimensions of cutout for wiring. Note: Be sure to remove the cutouts for wiring that are located in the wiring outlet direction before installing the Terminal Cover. 44 P9 MA DE IN EC -C JA PA N >P C< CCE 9 NA PA JN <C P> IE P DA 18 M 28 * 28 74 * * 20 30 18 * 27 38 44 4 * Dimension (mm) Tolerance (mm) 10 or lower ±0.3 10 to 50 ±0.5 50 or higher ±1 G9EC-1 DC Power Relays (200-A Models) - G 9 E C 1 • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation Electronic and Mechanical Components Company Contact: www.omron.com/ecb Cat. No. J188-E1-02 0316(0207)(O) 5