Rhinocast - Ductile Iron Access Covers and Frames

advertisement
Rhinocast - Ductile Iron Access Covers and Frames
Typical Applications
•
•
•
•
•
•
•
•
•
•
•
Internal areas
Streetscapes
Prestige/Aesthetic projects
Commercial areas
Industrial applications
Docks and ports
Airports
Ducting trenches
Roads and carriageways
Electrical and communications
Trade waste, sewer and storm water
Ductile iron strengthening ribs cast into the cover.
10
Class B Cover
with ‘T’ frame
Decorative edge can be attached to the cover
and frame for aesthetic areas. This adds 12mm
or 40mm to overall height to accomodate tiles
or pavers
Circular, square and rectangular covers are
available as recessed or solid top
Class D & G covers
with cellular frame
Circular covers
Product Features
•
•
•
•
•
•
•
•
All covers are designed to meet
Australian Standard AS 3996 Class B,
D or G loading
600/3 ductile iron cover to
AS 1831 and grey iron frame
All covers are sealed to 1.5kPa to
AS 3996 requirements
‘T’ or cellular frame provides excellent
anchorage of the frame into the
concrete bed
Drawcut/undercut profile of cover and
frame allows the cover to slide out, in
one direction only
Reinforcing ribs cast into the cover
provide required strength
Plastic dust caps prevent lifting boss’
filling with dirt and debris
Optional brass or stainless steel
decorative edging adds 12mm
or 40mm to overall height to
accomodate tiles or brick pavers
Rhinocast - Solid Top Ductile Iron Access Cover and Frame
Single part square units can be used
to provide access to underground
stormwater/sewer systems, electricity and
communication enclosures, greasetraps,
valves and junction boxes.
ductile iron cover with square pattern
anti-slip surface
Class B
Class D
14
hold-down bolts for added security
or for back pressure applications
Also available as 2 part,3 part, trench and multipart systems
/Þ«iÊ
Ê
Ê
%*4#
%*4#
%*4#
%*4#
%*4#
%*4#
%*4#
%*4#
%*4#
%*4#
Ê
%*4%
%*4%
%*4%
%*4%
%*4%
%*4%
%*4%
%*4%
%*4%
%*4%
*>ÀÌÊ i>ÀÊ"«i˜ˆ˜}Ê
"ÛiÀ>Ê
"ÛiÀ>ÊÊ
œÛiÀÊ
"ÛiÀ>Ê
œ°Ê
7ÊÝÊÊ­““®Ê 7ÊÝÊÊ­““®Ê i«Ì…Ê­““®Ê 7}ÌÊ­Ž}®Ê 7}ÌÊ­Ž}®Ê
iVœÀ>̈ÛiÊ
`}ˆ˜}IÊ
œVŽˆ˜}
"«Ìˆœ˜II
Ê
>ÃÃÊʇÊ-ÊΙ™ÈʇÊnäŽ
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
£x
#&44o
#&44o
#&44o
#&44o
#&44o
#&44o
#&44o
#&44o
#&44o
#&44o
45%##
45%##
45%##
45%##
45%##
45%##
45%##
45%##
45%##
45%##
#&44o
#&44o
#&44o
#&44o
#&44o
#&44o
#&44o
#&44o
#&44o
#&44o
45%##
45%##
45%##
45%##
45%##
45%##
45%##
45%##
45%##
45%##
>ÃÃÊʇÊ-ÊΙ™ÈʇÊÓ£äŽ
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
%FDPSBUJWF#SBTT#&
PS4UBJOMFTT4UFFM44
FEHJOHDBOCFBEEFEKVTUTQFDJGZ#&PS44BOEIFJHIUNNPSNN
BGUFSQBSUOP
0QUJPOBMMPDLJOHCPMUTBSFBWBJMBCMFGPSTFDVSJUZPSCBDLQSFTTVSFBQQMJDBUJPOTTQFDJGZTUBOEBSECPMUT-%
PS#BSSJCPMUT##
BGUFSQBSUOP
/Þ«iÊ
Ê
Ê
%*#
%*#
%*#
%*#
%*#
%*#
%*#
%*#
%*#
%*#
%*#
Ê
%*%
%*%
%*%
%*%
%*%
%*%
%*%
%*%
%*%
%*%
%*%
ÊÊÊÊ
%*(
%*(
%*(
%*(
%*(
%*(
*>ÀÌÊ i>ÀÊ"«i˜ˆ˜}Ê
"ÛiÀ>Ê
"ÛiÀ>ÊÊ
œÛiÀÊ
"ÛiÀ>Ê
œ°Ê
7ÊÝÊÊ­““®Ê 7ÊÝÊÊ­““®Ê i«Ì…Ê­““®Ê 7}ÌÊ­Ž}®Ê 7}ÌÊ­Ž}®Ê
iVœÀ>̈ÛiÊ
`}ˆ˜}IÊ
œVŽˆ˜}
"«Ìˆœ˜II
Ê
>ÃÃÊʇÊ-ÊΙ™ÈʇÊnäŽ
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
#&44
#&44
#&44
#&44
#&44
#&44
-%##
-%##
-%##
-%##
-%##
-%##
>ÃÃÊʇÊ-ÊΙ™ÈʇÊÓ£äŽ
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
>ÃÃÊʇÊ-ÊΙ™ÈʇʙääŽ
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
%FDPSBUJWF#SBTT#&
PS4UBJOMFTT4UFFM44
FEHJOHDBOCFBEEFEKVTUTQFDJGZ#&PS44BOEIFJHIUNNPSNN
BGUFSQBSUOP
0QUJPOBMMPDLJOHCPMUTBSFBWBJMBCMFGPSTFDVSJUZPSCBDLQSFTTVSFBQQMJDBUJPOTTQFDJGZTUBOEBSECPMUT-%
PS#BSSJCPMUT##
BGUFSQBSUOP
£Ç
/Þ«iÊ
Ê
Ê
%*#
%*#
%*#
%*#
%*#
%*#
%*#
%*#
%*#
%*#
%*#
%*#
%*#
%*#
%*#
Ê
%*%
%*%
%*%
%*%
%*%
%*%
%*%
%*%
%*%
%*%
%*%
%*%
%*%
%*%
%*%
%*%
Ê
%*(
%*(
%*(
%*(
%*(
%*(
%*(
%*(
*>ÀÌÊ i>ÀÊ"«i˜ˆ˜}Ê
"ÛiÀ>Ê
"ÛiÀ>ÊÊ
œÛiÀÊ
"ÛiÀ>Ê
œ°Ê
7ÊÝÊÊ­““®Ê 7ÊÝÊÊ­““®Ê i«Ì…Ê­““®Ê 7}ÌÊ­Ž}®Ê 7}ÌÊ­Ž}®Ê
iVœÀ>̈ÛiÊ
`}ˆ˜}IÊ
œVŽˆ˜}
"«Ìˆœ˜II
Ê
>ÃÃÊʇÊ-ÊΙ™ÈʇÊnäŽ
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
>ÃÃÊʇÊ-ÊΙ™ÈʇÊÓ£äŽ
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
>ÃÃÊʇÊ-ÊΙ™ÈʇʙääŽ
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
%FDPSBUJWF#SBTT#&
PS4UBJOMFTT4UFFM44
FEHJOHDBOCFBEEFEKVTUTQFDJGZ#&PS44BOEIFJHIUNNPSNN
BGUFSQBSUOP
0QUJPOBMMPDLJOHCPMUTBSFBWBJMBCMFGPSTFDVSJUZPSCBDLQSFTTVSFBQQMJDBUJPOTTQFDJGZTUBOEBSECPMUT-%
PS#BSSJCPMUT##
BGUFSQBSUOP
£™
Rhinocast - 3-part and Trench Run Recessed
Ductile Iron Access Covers and Frames
3-part and trench cover units combine
standard size covers in a single run. They
are used where a single part cover does
not offer a large enough clear opening or
where continuous access is required.
Common applications include grease
traps/arrestors, communications
enclosures, where access along the entire
run is needed. All covers can be removed
for full uninterrupted access or single
covers can provide access to specific
areas.
Covers are available to suit 550, 1,000
and 2,000 litre grease traps.
decorative edging will add
12mm or 40mm to overall
height to allow for brick pavers
and tiles
provided widths and loading are the
same, any standard covers can be
combined to create 2-part units
standard ductile iron covers to
AS 3996 class B, D or G
20
undercut/drawcut overlap seals
and supports the covers at the join
without the need for crossbars
class B has a ‘T’
frame and class D
and G have cellular
frames
frame fits around both covers without the
need for additional support, the undercut/
drawcut profile supports covers across the
middle
Trench Runs
Trench runs can be produced using any
standard covers in widths of 450, 600,
750 or 900mm and in any length from
2340mm/2390mm upwards in multiples
of 150mm.
/Þ«iÊ
Ê
Ê
%*#
%*#
%*#
%*#
%*#
%*#
%*#
%*#
%*#
%*#
%*#
%*#
%*#
%*#
Ê
%*%
%*%
%*%
%*%
%*%
%*%
%*%
%*%
%*%
%*%
%*%
%*%
%*%
%*%
Ê
%*(
%*(
%*(
%*(
%*(
%*(
%*(
%*(
%*(
%*(
*>ÀÌÊ i>ÀÊ"«i˜ˆ˜}IÊ "ÛiÀ>Ê
"ÛiÀ>ÊÊ
œÛiÀÊ
"ÛiÀ>Ê
œ°Ê
7ÊÝÊÊ­““®Ê 7ÊÝÊÊ­““®Ê i«Ì…Ê­““®Ê 7}ÌÊ­Ž}®Ê 7}ÌÊ­Ž}®Ê
iVœÀ>̈ÛiÊ
`}ˆ˜}IÊ
œVŽˆ˜}
"«Ìˆœ˜II
Ê
>ÃÃÊʇÊ-ÊΙ™ÈʇÊnäŽ
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
>ÃÃÊʇÊ-ÊΙ™ÈʇÊÓ£äŽ
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
>ÃÃÊʇÊ-ÊΙ™ÈʇʙääŽ
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
%FDPSBUJWF#SBTT#&
PS4UBJOMFTT4UFFM44
FEHJOHDBOCFBEEFEKVTUTQFDJGZ#&PS44BOEIFJHIUNNPSNN
BGUFSQBSUOP
0QUJPOBMMPDLJOHCPMUTBSFBWBJMBCMFGPSTFDVSJUZPSCBDLQSFTTVSFBQQMJDBUJPOTTQFDJGZTUBOEBSECPMUT-%
PS#BSSJCPMUT##
BGUFSQBSUOP
Ó£
Rhinocast - Multi-Part Recessed Ductile Iron Access Covers and Frame
Multipart units combine standard size
covers in multiple rows and lengths. They
are used where a single part cover does
not offer a large enough clear opening or
if smaller individual covers are required
for easier lifting.
Covers do not have to be the same length,
provided each row has covers of the same
width and load class.
Common applications include lift
motor rooms, access to large industrial
equipment, large electrical pits, pump
wells, container ports and transformers.
All covers and beams can be removed to
allow full uninterrupted access, or single
covers can be removed to provide access
to specific areas.
between the covers widthways, the cover
profiles are both undercut and therefore
require an additional centre frame to
provide the seal and a support beam to
take the loadings
individual ductile iron
covers tested to AS 3996
Class B, D or G
class B has a ‘T’ frame
and Class D and G have
cellular frames
overlap between the undercut
& drawcut profiles of the
covers lengthways provides
sufficient support and water
& gas seal that no additional
support is required
22
frame fits around all covers and a
removable frame and support beam is used
between rows
beam locating boxes
must be built into pit
construction
support beam sizes
are determined according to
loading and span requirements
Multi-part Design
Multi-part Sizes
The tables on pages 23-25 provide
information on the common multipart
sizes and is intended as a quick reference
guide.
Multi-parts are available in numerous
configurations and different cover sizes
can be combined to create a clear opening
to suit almost any requirement.
Due to the endless range of sizes
available, ACO will design the multipart closest to your requirements free of
charge and obligation, simply supply the
following information:
•
•
•
•
Clear opening
Load class
Position of obstacles that may affect
cover removal direction
Any width/slab depth restrictions
ACO will then provide:
•
•
•
Actual clear opening
Schedule of covers needed
Rebate drawing (which is essential for
correct installation)
/Þ«iÊ
Ê
Ê
%*.1#
%*.1#
%*.1#
%*.1#
%*.1#
%*.1#
%*.1#
%*.1#
Ê
%*.1%
%*.1%
%*.1%
%*.1%
%*.1%
%*.1%
%*.1%
%*.1%
*>ÀÌÊ
œ°Ê
i>ÀÊ"«i˜ˆ˜}Ê
7ÊÝÊÊ­““®Ê
œÊ
*>ÀÌÃÊ
œÛiÀÃÊ
7ÊÝÊÊ
œ>`Êi>Àˆ˜}Ê
i>“ÃÊ,iµÕˆÀi`Ê
iVœÀ>̈ÛiÊ
`}ˆ˜}IÊ
œVŽˆ˜}
"«Ìˆœ˜II
Y
Y
Y
Y
Y
Y
Y
Y
YNN6$
YNN6$
YNN6$
YNN6$
YNN6$
YNN6$
YNN6$
YNN6$
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
Y
Y
Y
Y
Y
Y
Y
Y
YNN6$
YNN6$
YNN6$
YNN6$
YNN6#
YNN6#
YNN6#
YNN6#
#&44
#&44
#&44
#&44
#&44
#&44
#&44
#&44
-%##
-%##
-%##
-%##
-%##
-%##
-%##
-%##
Ê >ÃÃÊʇÊ-ÊΙ™ÈʇÊnäŽ
Y
Y
Y
Y
Y
Y
Y
Y
1BSU
1BSU
1BSU
1BSU
1BSU
1BSU
1BSU
1BSU
>ÃÃÊʇÊ-ÊΙ™ÈʇÊÓ£äŽ
Y
Y
Y
Y
Y
Y
Y
Y
1BSU
1BSU
1BSU
1BSU
1BSU
1BSU
1BSU
1BSU
%FDPSBUJWF#SBTT#&
PS4UBJOMFTT4UFFM44
FEHJOHDBOCFBEEFEKVTUTQFDJGZ#&PS44BOEIFJHIUNNPSNN
BGUFSQBSUOP
0QUJPOBMMPDLJOHCPMUTBSFBWBJMBCMFGPSTFDVSJUZPSCBDLQSFTTVSFBQQMJDBUJPOTTQFDJGZTUBOEBSECPMUT-%
PS#BSSJCPMUT##
BGUFSQBSUOP
-iiÊ«>}iÃÊÓ{ÊEÊÓxÊvœÀʜ̅iÀÊÈâiÃÊ>˜`ÊVœÛiÀÊVœ“Lˆ˜>̈œ˜Ã
ÓÎ
24
1095
4-Part
4-Part
4-Part
6-Part
6-Part
6-Part
6-Part
8-Part
8-Part
8-Part
8-Part
8-Part
10-Part
10-Part
10-Part
10-Part
10-Part
12-Part
12-Part
12-Part
12-Part
12-Part
14-Part
14-Part
14-Part
14-Part
14-Part
16-Part
16-Part
945
4-Part
4-Part
4-Part
6-Part
6-Part
6-Part
6-Part
8-Part
8-Part
8-Part
8-Part
8-Part
10-Part
10-Part
10-Part
10-Part
10-Part
12-Part
12-Part
12-Part
12-Part
12-Part
14-Part
14-Part
14-Part
14-Part
14-Part
16-Part
16-Part
4-Part
4-Part
4-Part
6-Part
6-Part
6-Part
6-Part
8-Part
8-Part
8-Part
8-Part
8-Part
10-Part
10-Part
10-Part
10-Part
10-Part
12-Part
12-Part
12-Part
12-Part
12-Part
14-Part
14-Part
14-Part
14-Part
14-Part
16-Part
16-Part
1245
1440
100UC
6-Part
6-Part
6-Part
9-Part
9-Part
9-Part
9-Part
12-Part
12-Part
12-Part
12-Part
12-Part
15-Part
15-Part
15-Part
15-Part
15-Part
18-Part
18 Part
18-Part
18 Part
18-Part
21-Part
21-Part
21-Part
21-Part
21-Part
24-Part
24-Part
1590
Beam
6-Part
6-Part
6-Part
9-Part
9-Part
9-Part
9-Part
12-Part
12-Part
12-Part
12-Part
12-Part
15-Part
15-Part
15-Part
15-Part
15-Part
18-Part
18 Part
18-Part
18 Part
18-Part
21-Part
21-Part
21-Part
21-Part
21-Part
24-Part
24-Part
6-Part
6-Part
6-Part
9-Part
9-Part
9-Part
9-Part
12-Part
12-Part
12-Part
12-Part
12-Part
15-Part
15-Part
15-Part
15-Part
15-Part
18-Part
18 Part
18-Part
18 Part
18-Part
21-Part
21-Part
21-Part
21-Part
21-Part
24-Part
24-Part
1740
6-Part
6-Part
6-Part
9-Part
9-Part
9-Part
9-Part
12-Part
12-Part
12-Part
12-Part
12-Part
15-Part
15-Part
15-Part
15-Part
15-Part
18-Part
18 Part
18-Part
18 Part
18-Part
21-Part
21-Part
21-Part
21-Part
21-Part
24-Part
24-Part
1890
8-Part
8-Part
8-Part
12-Part
12-Part
12-Part
12-Part
16-Part
16-Part
16-Part
16-Part
16-Part
20-Part
20-Part
20-Part
20-Part
20-Part
24-Part
24-Part
24-Part
24-Part
24-Part
28-Part
28-Part
28-Part
28-Part
28-Part
32-Part
32-Part
1935
8-Part
8-Part
8-Part
12-Part
12-Part
12-Part
12-Part
16-Part
16-Part
16-Part
16-Part
16-Part
20-Part
20-Part
20-Part
20-Part
20-Part
24-Part
24-Part
24-Part
24-Part
24-Part
28-Part
28-Part
28-Part
28-Part
28-Part
32-Part
32-Part
2085
8-Part
8-Part
8-Part
12-Part
12-Part
12-Part
12-Part
16-Part
16-Part
16-Part
16-Part
16-Part
20-Part
20-Part
20-Part
20-Part
20-Part
24-Part
24-Part
24-Part
24-Part
24-Part
28-Part
28-Part
28-Part
28-Part
28-Part
32-Part
32-Part
2235
8-Part
8-Part
8-Part
12-Part
12-Part
12-Part
12-Part
16-Part
16-Part
16-Part
16-Part
16-Part
20-Part
20-Part
20-Part
20-Part
20-Part
24-Part
24-Part
24-Part
24-Part
24-Part
28-Part
28-Part
28-Part
28-Part
28-Part
32-Part
32-Part
2385
8-Part
8-Part
8-Part
12-Part
12-Part
12-Part
12-Part
16-Part
16-Part
16-Part
16-Part
16-Part
20-Part
20-Part
20-Part
20-Part
20-Part
24-Part
24-Part
24-Part
24-Part
24-Part
28-Part
28-Part
28-Part
28-Part
28-Part
32-Part
32-Part
2535
Span
Width/Beam
1300
1450
1600
2000
2150
2300
2450
2700
2850
3000
3150
3300
3400
3550
3700
3850
4000
4150
4250
4400
4550
4700
4850
5000
1395
4-Part
4-Part
4-Part
6-Part
6-Part
6-Part
6-Part
8-Part
8-Part
8-Part
8-Part
8-Part
10-Part
10-Part
10-Part
10-Part
10-Part
10-Part
12-Part
12-Part
12-Part
12-Part
12-Part
12-Part
1245
4-Part
4-Part
4-Part
6-Part
6-Part
6-Part
6-Part
8-Part
8-Part
8-Part
8-Part
8-Part
10-Part
10-Part
10-Part
10-Part
10-Part
10-Part
12-Part
12-Part
12-Part
12-Part
12-Part
12-Part
1545
100UC Beam
4-Part
4-Part
4-Part
6-Part
6-Part
6-Part
6-Part
8-Part
8-Part
8-Part
8-Part
8-Part
10-Part
10-Part
10-Part
10-Part
10-Part
10-Part
12-Part
12-Part
12-Part
12-Part
12-Part
12-Part
6-Part
6-Part
6-Part
9-Part
9-Part
9-Part
9-Part
12-Part
12-Part
12-Part
12-Part
12-Part
15-Part
15-Part
15-Part
15-Part
15-Part
15-Part
18-Part
18-Part
18-Part
18-Part
18-Part
18-Part
1890
6-Part
6-Part
6-Part
9-Part
9-Part
9-Part
9-Part
12-Part
12-Part
12-Part
12-Part
12-Part
15-Part
15-Part
15-Part
15-Part
15-Part
15-Part
18-Part
18-Part
18-Part
18-Part
18-Part
18-Part
2040
6-Part
6-Part
6-Part
9-Part
9-Part
9-Part
9-Part
12-Part
12-Part
12-Part
12-Part
12-Part
15-Part
15-Part
15-Part
15-Part
15-Part
15-Part
18-Part
18-Part
18-Part
18-Part
18-Part
18-Part
2190
6-Part
6-Part
6-Part
9-Part
9-Part
9-Part
9-Part
12-Part
12-Part
12-Part
12-Part
12-Part
15-Part
15-Part
15-Part
15-Part
15-Part
15-Part
18-Part
18-Part
18-Part
18-Part
18-Part
18-Part
2340
8-Part
8-Part
8-Part
12-Part
12-Part
12-Part
12-Part
16-Part
16-Part
16-Part
16-Part
16-Part
20-Part
20-Part
20-Part
20-Part
20-Part
20-Part
24-Part
24-Part
24-Part
24-Part
24-Part
24-Part
2535
2685
150UC Beam
8-Part
8-Part
8-Part
12-Part
12-Part
12-Part
12-Part
16-Part
16-Part
16-Part
16-Part
16-Part
20-Part
20-Part
20-Part
20-Part
20-Part
20-Part
24-Part
24-Part
24-Part
24-Part
24-Part
24-Part
8-Part
8-Part
8-Part
12-Part
12-Part
12-Part
12-Part
16-Part
16-Part
16-Part
16-Part
16-Part
20-Part
20-Part
20-Part
20-Part
20-Part
20-Part
24-Part
24-Part
24-Part
24-Part
24-Part
24-Part
2835
8-Part
8-Part
8-Part
12-Part
12-Part
12-Part
12-Part
16-Part
16-Part
16-Part
16-Part
16-Part
20-Part
20-Part
20-Part
20-Part
20-Part
20-Part
24-Part
24-Part
24-Part
24-Part
24-Part
24-Part
2985
8-Part
8-Part
8-Part
12-Part
12-Part
12-Part
12-Part
16-Part
16-Part
16-Part
16-Part
16-Part
20-Part
20-Part
20-Part
20-Part
20-Part
20-Part
24-Part
24-Part
24-Part
24-Part
24-Part
24-Part
3135
10-Part
10-Part
10-Part
15-Part
15-Part
15-Part
15-Part
20-Part
20-Part
20-Part
20-Part
20-Part
25-Part
25-Part
25-Part
25-Part
25-Part
30-Part
30-Part
30-Part
30-Part
30-Part
35-Part
35-Part
35-Part
35-Part
35-Part
40-Part
40-Part
2880
10-Part
10-Part
10-Part
15-Part
15-Part
15-Part
15-Part
20-Part
20-Part
20-Part
20-Part
20-Part
25-Part
25-Part
25-Part
25-Part
25-Part
30-Part
30-Part
30-Part
30-Part
30-Part
35-Part
35-Part
35-Part
35-Part
35-Part
40-Part
40-Part
3030
10-Part
10-Part
10-Part
15-Part
15-Part
15-Part
15-Part
20-Part
20-Part
20-Part
20-Part
20-Part
25-Part
25-Part
25-Part
25-Part
25-Part
30-Part
30-Part
30-Part
30-Part
30-Part
35-Part
35-Part
35-Part
35-Part
35-Part
40-Part
40-Part
3180
Notes.
1. Rhinocast Multi-Part systems are available
in a choice of recessed and solid top covers.
2. Beams are positioned parallel to the span.
3. All dimensions are clear openings.
4. This table only contains typical
combinations, contact ACO for other
possibilities.
Class B 80kN
2580
2730
150UC Beam
10-Part
10-Part
10-Part
10-Part
10-Part
10-Part
15-Part
15-Part
15-Part
15-Part
15-Part
15-Part
15-Part
15-Part
20-Part
20-Part
20-Part
20-Part
20-Part
20-Part
20-Part
20-Part
20-Part
20-Part
25-Part
25-Part
25-Part
25-Part
25-Part
25-Part
25-Part
25-Part
25-Part
25-Part
30-Part
30-Part
30-Part
30-Part
30-Part
30-Part
30-Part
30-Part
30-Part
30-Part
35-Part
35-Part
35-Part
35-Part
35-Part
35-Part
35-Part
35-Part
35-Part
35-Part
40-Part
40-Part
40-Part
40-Part
This table contains cover quantities for multi-part systems comprising cover sizes 600 x 600, 600 x 750, 750 x 600, 750 x 750
Span
Width/Beam
1000
1150
1300
1550
1700
1850
2000
2100
2250
2400
2550
2700
2800
2950
3100
3250
3400
3500
3650
3800
3950
4100
4200
4350
4500
4650
4800
4900
5050
This table contains cover quantities for multi-part systems comprising cover sizes 450 x 450, 450 x 600, 600 x 450, 600 x 600
Typical Multi-Part Rhinocast Combinations for Class B
1120
4-Part
4-Part
4-Part
6-Part
6-Part
6-Part
6-Part
8-Part
8-Part
8-Part
8-Part
8-Part
10-Part
10-Part
10-Part
10-Part
10-Part
12-Part
12-Part
12-Part
12-Part
12-Part
14-Part
14-Part
14-Part
14-Part
14-Part
970
4-Part
4-Part
4-Part
6-Part
6-Part
6-Part
6-Part
8-Part
8-Part
8-Part
8-Part
8-Part
10-Part
10-Part
10-Part
10-Part
10-Part
12-Part
12-Part
12-Part
12-Part
12-Part
14-Part
14-Part
14-Part
14-Part
14-Part
1270
150UC Beam
4-Part
4-Part
4-Part
6-Part
6-Part
6-Part
6-Part
8-Part
8-Part
8-Part
8-Part
8-Part
10-Part
10-Part
10-Part
10-Part
10-Part
12-Part
12-Part
12-Part
12-Part
12-Part
14-Part
14-Part
14-Part
14-Part
14-Part
1490
6-Part
6-Part
6-Part
9-Part
9-Part
9-Part
9-Part
12-Part
12-Part
12-Part
12-Part
12-Part
15-Part
15-Part
15-Part
15-Part
15-Part
18-Part
18-Part
18-Part
18-Part
18-Part
21-Part
21-Part
21-Part
21-Part
21-Part
1640
6-Part
6-Part
6-Part
9-Part
9-Part
9-Part
9-Part
12-Part
12-Part
12-Part
12-Part
12-Part
15-Part
15-Part
15-Part
15-Part
15-Part
18-Part
18-Part
18-Part
18-Part
18-Part
21-Part
21-Part
21-Part
21-Part
21-Part
1790
6-Part
6-Part
6-Part
9-Part
9-Part
9-Part
9-Part
12-Part
12-Part
12-Part
12-Part
12-Part
15-Part
15-Part
15-Part
15-Part
15-Part
18-Part
18-Part
18-Part
18-Part
18-Part
21-Part
21-Part
21-Part
21-Part
21-Part
1940
6-Part
6-Part
6-Part
9-Part
9-Part
9-Part
9-Part
12-Part
12-Part
12-Part
12-Part
12-Part
15-Part
15-Part
15-Part
15-Part
15-Part
18-Part
18-Part
18-Part
18-Part
18-Part
21-Part
21-Part
21-Part
21-Part
21-Part
2010
250UB Beam
8-Part
8-Part
8-Part
12-Part
12-Part
12-Part
12-Part
16-Part
16-Part
16-Part
16-Part
16-Part
20-Part
20-Part
20-Part
20-Part
20-Part
24-Part
24-Part
24-Part
24-Part
24-Part
28-Part
28-Part
28-Part
28-Part
28-Part
2160
8-Part
8-Part
8-Part
12-Part
12-Part
12-Part
12-Part
16-Part
16-Part
16-Part
16-Part
16-Part
20-Part
20-Part
20-Part
20-Part
20-Part
24-Part
24-Part
24-Part
24-Part
24-Part
28-Part
28-Part
28-Part
28-Part
28-Part
2310
8-Part
8-Part
8-Part
12-Part
12-Part
12-Part
12-Part
16-Part
16-Part
16-Part
16-Part
16-Part
20-Part
20-Part
20-Part
20-Part
20-Part
24-Part
24-Part
24-Part
24-Part
24-Part
28-Part
28-Part
28-Part
28-Part
28-Part
2460
8-Part
8-Part
8-Part
12-Part
12-Part
12-Part
12-Part
16-Part
16-Part
16-Part
16-Part
16-Part
20-Part
20-Part
20-Part
20-Part
20-Part
24-Part
24-Part
24-Part
24-Part
24-Part
28-Part
28-Part
28-Part
28-Part
28-Part
2610
8-Part
8-Part
8-Part
12-Part
12-Part
12-Part
12-Part
16-Part
16-Part
16-Part
16-Part
16-Part
20-Part
20-Part
20-Part
20-Part
20-Part
24-Part
24-Part
24-Part
24-Part
24-Part
28-Part
28-Part
28-Part
28-Part
28-Part
Span
Width/Beam
1350
1500
1650
2100
2250
2400
2550
2850
3000
3150
3300
3450
3600
3750
3900
4050
4200
4350
4500
4650
4800
4950
5100
1270
1420
150UC Beam
4-Part
4-Part
4-Part
4-Part
4-Part
4-Part
6-Part
6-Part
6-Part
6-Part
6-Part
6-Part
6-Part
6-Part
8-Part
8-Part
8-Part
8-Part
8-Part
8-Part
8-Part
8-Part
8-Part
8-Part
10-Part
10-Part
10-Part
10-Part
10-Part
10-Part
10-Part
10-Part
10-Part
10-Part
10-Part
10-Part
12-Part
12-Part
12-Part
12-Part
12-Part
12-Part
12-Part
12-Part
12-Part
12-Part
1940
6-Part
6-Part
6-Part
9-Part
9-Part
9-Part
9-Part
12-Part
12-Part
12-Part
12-Part
12-Part
15-Part
15-Part
15-Part
15-Part
15-Part
15-Part
18-Part
18-Part
18-Part
18-Part
18-Part
1570
4-Part
4-Part
4-Part
6-Part
6-Part
6-Part
6-Part
8-Part
8-Part
8-Part
8-Part
8-Part
10-Part
10-Part
10-Part
10-Part
10-Part
10-Part
12-Part
12-Part
12-Part
12-Part
12-Part
2090
250UB
6-Part
6-Part
6-Part
9-Part
9-Part
9-Part
9-Part
12-Part
12-Part
12-Part
12-Part
12-Part
15-Part
15-Part
15-Part
15-Part
15-Part
15-Part
18-Part
18-Part
18-Part
18-Part
18-Part
2240
Beam
6-Part
6-Part
6-Part
9-Part
9-Part
9-Part
9-Part
12-Part
12-Part
12-Part
12-Part
12-Part
15-Part
15-Part
15-Part
15-Part
15-Part
15-Part
18-Part
18-Part
18-Part
18-Part
18-Part
2610
8-Part
8-Part
8-Part
12-Part
12-Part
12-Part
12-Part
16-Part
16-Part
16-Part
16-Part
16-Part
20-Part
20-Part
20-Part
20-Part
20-Part
20-Part
24-Part
24-Part
24-Part
24-Part
24-Part
2390
6-Part
6-Part
6-Part
9-Part
9-Part
9-Part
9-Part
12-Part
12-Part
12-Part
12-Part
12-Part
15-Part
15-Part
15-Part
15-Part
15-Part
15-Part
18-Part
18-Part
18-Part
18-Part
18-Part
2760
8-Part
8-Part
8-Part
12-Part
12-Part
12-Part
12-Part
16-Part
16-Part
16-Part
16-Part
16-Part
20-Part
20-Part
20-Part
20-Part
20-Part
20-Part
24-Part
24-Part
24-Part
24-Part
24-Part
2910
310UB Beam
8-Part
8-Part
8-Part
12-Part
12-Part
12-Part
12-Part
16-Part
16-Part
16-Part
16-Part
16-Part
20-Part
20-Part
20-Part
20-Part
20-Part
20-Part
24-Part
24-Part
24-Part
24-Part
24-Part
3060
8-Part
8-Part
8-Part
12-Part
12-Part
12-Part
12-Part
16-Part
16-Part
16-Part
16-Part
16-Part
20-Part
20-Part
20-Part
20-Part
20-Part
20-Part
24-Part
24-Part
24-Part
24-Part
24-Part
3210
8-Part
8-Part
8-Part
12-Part
12-Part
12-Part
12-Part
16-Part
16-Part
16-Part
16-Part
16-Part
20-Part
20-Part
20-Part
20-Part
20-Part
20-Part
24-Part
24-Part
24-Part
24-Part
24-Part
2830
10-Part
10-Part
10-Part
15-Part
15-Part
15-Part
15-Part
20-Part
20-Part
20-Part
20-Part
20-Part
25-Part
25-Part
25-Part
25-Part
25-Part
30-Part
30-Part
30-Part
30-Part
30-Part
35-Part
35-Part
35-Part
35-Part
35-Part
2980
10-Part
10-Part
10-Part
15-Part
15-Part
15-Part
15-Part
20-Part
20-Part
20-Part
20-Part
20-Part
25-Part
25-Part
25-Part
25-Part
25-Part
30-Part
30-Part
30-Part
30-Part
30-Part
35-Part
35-Part
35-Part
35-Part
35-Part
Notes.
1. Rhinocast Multi-Part systems are available
in a choice of recessed and solid top covers.
2. Beams are positioned parallel to the span.
3. All dimensions are clear openings.
4. This table only contains typical
combinations, contact ACO for other
possibilities.
Class D 210kN
2680
310UB Beam
10-Part
10-Part
10-Part
15-Part
15-Part
15-Part
15-Part
20-Part
20-Part
20-Part
20-Part
20-Part
25-Part
25-Part
25-Part
25-Part
25-Part
30-Part
30-Part
30-Part
30-Part
30-Part
35-Part
35-Part
35-Part
35-Part
35-Part
This table contains cover quantities for multi-part systems comprising cover sizes 600 x 600, 600 x 750, 750 x 600, 750 x 750
Span
Width/Span
1050
1200
1350
1650
1800
1950
2100
2250
2400
2550
2700
2850
3000
3150
3300
3450
3600
3750
3900
4050
4200
4350
4500
4650
4800
4950
5100
This table contains cover quantities for multi-part systems comprising cover sizes 450 x 450, 450 x 600, 600 x 450, 600 x 600
Typical Multi-Part Rhinocast Combinations for Class D
25
Download