HFW Standard 23" Full Cutoff High-Bay Product Information Project Name Type Catalog Number Date SPECIFICATIONS Features • • • • • • • • • • • Energy-efficient fluorescent luminaire replaces HID in multiple applications. Full bodied fixture protects lamps from incidental contact. Deep body provides thermal control, long life and durability of components. Optional fully ventilated body and endplates to help reduce heat in ballast compartment for longer life. Optional end mount sensor for additional savings in unoccupied spaces. Ballast is attached to ballast cover plate in ballast cavity to extend life in high ambient temperatures. Available up to 8 lamp cross section. Optional wireguard or lens available in recessed hinged frame. Excellent lumen maintenance (95% versus ~65% for typical metal halide). Superior color rendering (82 CRI, versus 65-70 for metal halide). Made In USA. Meets ARRA & Buy American requirements. Construction • Full cutoff housing available in aluminum or steel • Multiple reflector options available for high and low-bay mounting and distribution applications • Standard mounting holes and v-hangers included • Optional hinged and gasketed lens door • Weight: 2x4-15 lbs. Certifications • UL 1598 listed for Canada and U.S. • Luminaires bear appropriate listing labels. • Emergency-equipped fixtures labeled UL 924. Electrical • • • • • • • • Application Input Voltage Range: 100-277 VAC Nom. (90-305 V Min/Max) Lamp frequency: > 42 kHz Power Factor: >0.9% @ full load, 100V through 277V Harmonic Distortion: THD < 20% @ full load Protection: Over-Voltage, Over-Current & Short Circuit with self-recovery Compliant to FCC 47CFR Part 18 Non-consumer Class A Sound Rating Optional emergency battery backup Optional step down transformer, drops 480 VAC to 277 VAC • Open fixtures suitable up to 50°C/122°F • Suitable for use with most wired or wireless lighting control systems • Suitable for dry & damp locations: • Manufacturing • Factory • Warehouses • Storage • Commercial • High-Bay • Industrial • Low-Bay ORDERING INFORMATION – MODEL HFW Standard Body SIZE 2x4 2x4 Nominal LAMP QTY – – – – – – – LAMP TYPE BALLAST FACTOR2 BALLAST GRADE T5HO T5HO T8 T8 LP Low Power ST Standard BALLAST VOLTAGE1 UL x Universal 4L 4 Lamp 120-277 VAC 5L 5 Lamp UHx 347-480 6L 6 Lamp EXAMPLE HFW-2X4-6L-T8-UL2-HP-33IS-UE-EA-CR VAC 8L 8 Lamp (.75-.78) MP Medium Power (.85-.88) MN Neutral Power (.97-1.04) HP High Power (1.15-1.20) BALLAST STARTING3 IS Instant Start ISD Instant Start Step Dimming PS Programmed Start Grade UE Ultra Efficient REFLECTOR MATERIAL EA Enhanced Aluminum 95% – OTHER WG WW CA CP Zinc Wireguard White Wireguard Clear Acrylic Lens Clear Polycarbonate Lens VNT Vented Body HB 2 Point Mount Dedicated Hanging Brackets HBTB Hanging Brackets + WA White Aluminum DSTB Dottie Slots + 91-93% Reflector 90-91% BODY MATERIAL CR 22 Gauge Cold Rolled Steel Body Rolled Steel Body 1. Numeral indicates number of ballasts per fixture. 2. "MN" Ballast factor not for use with T8/ISD or T8/PS. 3. When using UL2, identify number of lamps powered by each ballast before starting method. Largest number first. Ex: 42PS = 6LT5HO. 4. Contact factory for additional cord & mounting options. 5. Numeral indicates number of lamps controlled, HBA is std. For Wattstopper, specify -WS after sensor option. – MM Micro Matte CD 20 Gauge Cold FOOTNOTES – HA Heavy Duty Top Mount Box Top Mount Box TRS Step Down Transformer (Takes 480 to 277 VAC) – CORD PLUG4 C6 6' Cord, No Plug – OTHER LF Factory Lamps (Lamp spec elsewhere) C6/ 6' Cord & L715 Plug PF Partial/Full C6/515 6' Cord & EB Emergency (L7-15P) Plug (515P) PQC15 15' Cord/ Quick Connect OCC SENSOR5 Switch Battery Backup 1PK Individually Boxed Fixture SHx Standard 360° View High-Bay Sensor RHx Rectangular Aisle View High-Bay Sensor SLx Standard 360° View Low-Bay Sensor Aluminum Body Page 1/3 - Revised: 05/26/16 | Created: 2016 © 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com HFW Standard 23" Full Cutoff High-Bay PHOTOMETRIC DATA PHOTOMETRIC DATA: HFW-2X4-6L-T8-UL1-HP-IS-ST-EA LUMINAIRE DATA Ballast Ballast Factor Lamp Fixture Lumens Watts Fixture Efficiency Mounting Shielding Angle Spacing Criterion Luminous Opening in feet HFW-2X4-6L-T8-UL1-HP-IS-ST-EA 2X4 Standard 17 " Full Cutoff High-Bay (2) 3L32-HP 1.00 F32 15598 221 87% Suspended 0° = 90 90° = 90 0° = 1.26 90° = 1.60 Length: 4.00 Width: 1.81 Height: 0.00 90 RCR RC 50 103 89 76 66 58 51 46 41 37 33 31 10 103 81 64 52 44 37 31 27 24 21 19 70 101 91 82 74 67 61 56 52 48 44 42 50 101 87 75 65 57 50 45 40 36 33 30 %Fixt 17 33 65 87 20 38 75 100 70 60 AVG. LUMINANCE (Candela/Sq. M.) 4691 50 6255 0 10 20 50 30 101 83 69 58 49 42 37 32 29 26 23 %Lamp 3111 5981 11759 15598 3128 70 30 103 84 70 59 50 43 37 33 29 26 23 Lumens 0-30 0-40 0-60 0-90 80 30 40 0.0 _____ 40.0 _ _ _ _ 90.0 _ _ _ _ 80 70 103 93 84 76 69 63 58 53 49 46 43 Zone 1564 COEFFICIENTS OF UTILIZATION (%) RW 0 1 2 3 4 5 6 7 8 9 10 ZONAL LUMEN SUMMARY Average Luminance Angle Luminaire INDOOR CANDELA PLOT 10 101 79 64 52 43 37 31 27 24 21 18 50 92 83 71 62 55 48 43 39 35 32 29 30 92 80 66 56 48 41 36 32 28 25 23 0 10 92 77 62 51 43 36 31 27 23 21 18 0 83 70 57 47 39 33 28 25 21 19 17 0 5 15 25 35 45 55 65 75 85 0.0 22.5 45.0 67.5 90 4286 4255 4097 3795 3358 2811 2181 1488 780 142 4286 4363 4750 5102 5020 4351 3346 1941 809 173 4286 4603 5686 5943 5346 4228 2525 1564 807 171 4286 4804 6145 6067 5265 3541 2352 1529 795 173 4286 4869 6255 6095 5140 3314 2344 1528 790 170 RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance MOUNTING OPTIONS - SUSPENDED DOTTIE SLOT WITH V-HANGER GRIPPLE LOOP Included Order Separately HB 2-POINT HANGING BRACKETS V-HANGER Optional - Factory Installed Included DOTTIE SLOT WITH V-HANGER GRIPPLE LOOP Order Separately TOP BOX FOR POWER SUPPLY Included Optional 4" OR GRIPPLE LOOP Order Separately 4" 2" Page 2/3 - Revised: 05/26/16 | Created: 2016 © 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com HFW Standard 23" Full Cutoff High-Bay FIXTURE DIMENSIONS END VIEW (8 LAMP T8) 3.808" 23.500" TOP VIEW 48.0000" 23.500" *Drawings N.T.S. EXISTING VS. PROPOSED HIGH-BAY SYSTEM Existing High-Bay System Lamp Quantity & Type Initial Lamp Lumens Lumen Maintenance EOL (1) Lumens All Lamps Total Fixture Lumens MH250 HPS400 MH1000 (12k Hours) MH1000 (8k Hours) 1 1 1 1 20,500 50,000 110,000 110,000 58% 70% 37% 50% 11,890 35,000 40,700 55,000 11,890 35,000 40,700 55,000 Proposed High-Bay System Lamp Quantity & Type Initial Lamp Lumens Lumen Maintenance EOL (1) Lumens All Lamps Total Fixture Lumens 5,000 5,000 5,000 93% 93% 93% 4,650 4,650 4,650 18,600 27,900 37,200 4L-T5HO 6L-T5HO 8L-T5HO 4 6 8 Std. MH250 Std. HPS400 MH1000/U MH1000/U FP54T5HO FP54T5HO FP54T5HO EOL (1) Ballast Fixture Lumens Per Factor Efficiency Fixture 1.00 1.00 1.00 1.00 0.75 0.75 0.75 0.75 8,198 26,250 30,525 41,250 EOL (1) Ballast Fixture Lumens Per Factor Efficiency Fixture 1.00 1.00 1.00 0.92 0.92 0.92 17,112 25,668 34,224 S/P (2) Ratio Net (3) EOL Lumens Fixture Input Watts 1.49 0.62 1.49 1.49 12,171 18,080 41,662 56,300 295 464 1080 1080 S/P (2) Ratio Net (3) EOL Lumens Fixture Input Watts 1.62 1.62 1.62 24,930 37,395 49,860 234 351 468 147 4L-T8 Plus 4 F32T8/841 2,950 90% 2,655 10,620 1.14 0.90 10,896 1.62 15,874 6L-T8 Plus 6 F32T8/841 2,950 90% 2,655 15,930 1.18 0.90 16,918 1.62 24,647 218 8L-T8 Plus 8 F32T8/841 2,950 90% 2,655 21,240 1.14 0.90 21,792 1.62 31,749 294 (1) EOL = End of life (2) S/P Ratio = Scotopic to Photopic Lumens (3) Net EOL Lumens = EOL Lumens Per Fixture x (S/P).78 [.78 exponent] *Lamp/ballast system values shown are a general reference intended to supply a quick comparison of several common lamp/ballast systems, the associated energy consumption, and net lumen output. *Values shown are based on normal operating temperatures (25°C T8 and 35°C T5) and at 277 volts. *Fixture efficiency percentages are generally representative of each system type, actual values will vary. *There are many operating variables that affect system output, in addition to rating variances from brand to brand. *All T8 electronic ballast values shown are based on Ultra Efficient (aka 3rd Generation) T8 ballasts. *All T5 and T8 lamp values shown are for basic grade lamps. Extended life and higher lumen lamp types are available. *In addition to those shown, there are a wide variety of systems to choose from, each with distinct features and cost points. *Please consult the lamp/ballast manufacturer's catalogs for the detailed information required to model your system. Page 3/3 - Revised: 05/26/16 | Created: 2016 © 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com