Product sheet RA and RB

advertisement
Product sheet RA och RB 2012-06-01
DUCTS RA and RB
Sound attenuating rectangular duct with
integrated grille for hidden air intake
• Manufactured in high quality Aluzink sheet steel
• Duct opens below window ledge which acts as weather protection
• Delivered custom cut to length
• Usual solution together with Easy-Vent with top connection (Easy-Vent-D-T och -E-T) and air terminals Flexi in series Easy-Vent for renovation
design
Sound attenuation
RA and sound attenuating RB are rectangular ducts with
integrated grilles and tabs for fastening to the wall. They are
often mounted in connection with the changing of windows,
but are also used in new construction. These duct opens
discretely under the window ledge and for this reason have
no effect on the appearance of the facade. The window
ledge also provides protection against the weather. Ducts RA
and RB are used together with the Easy-Vent air terminal with
top connection and air terminals Flexi in the series Easy-Vent
for renovation.
The sound attenuating duct RB uses the wall’s insulation as
an absorption material. They only function in stud framed
walls with mineral wool (fibre glass or rock wool) insulation.
RA and RB are manufactured in Aluzink sheet steel, a durable
material with very good anti-corrosion characteristics. This is
important since the duct is intended to have the same length
of life as the building in which it is installed.
The table below shows the reduction coefficient for a
complete installation consisting of Easy-Vent or Flexi, RA
or RB duct and radiator.
Reduction coefficient Dn,e,w ref. 10 m2 is measured according to ISO 140-10 and SS-EN ISO 717. Contact Acticon if
you would like more information about the actual
modification terms.
RA and RB duct below window ledge
Easy-Vent with top connection and Flexi (Easy-Vent for
renovation)
Dn,e,w
Duct
Stud framed wall Concrete
with mineral wool
46
RB
X
37
RA
X
X
dimensions
35
*)
250 mm
*) dimensions modified to suit actual wall construction
1
Acticon AB • Sjöåkravägen 30 • SE-564 31 Bankeryd • Sweden • Tel +46 (0)36 370790 • www.acticon.se
Right to design and construction changes reserved • Copyright © Acticon AB
The duct’s dimensions according to the drawing below.
Note that the dimensions of the hole shall always be a
least 5 mm larger than the dimensions given.