ADEO T8 Inaccessible Installation * T8 Fixture has housing extension. Read instructions to acomodate for extension. Step 1: Rough in Step 2: Setting up the Flange Kit 1. Build ceiling framing using Dim “A” and “B” 2. Make appropriate cut out in drywall using Dim “A” and “C” (see dimension chart below). 3. Install flange kit. 1. Slide (snap-lock) corner angles into the inboard side of the side rail and end/intermediate rail as shown. 2. Place assembled flange into ceiling opening and tie off to structure using tie wires (by others) on all four corners. 1x2 Step Blocking End/Intermediate rail Corner angle Drywall Tie Wire Support (By others) Ceiling Bracing Flange Kit (By others) +1/8” “B” -0” Dimension Chart Fixture Size Dim “A” Dim “B” Dim “C” 1x4 12-1/4” 49-3/4” 48-1/4” 2x2 24-1/4” 25-3/4” 24-1/4” 2x4 24-1/4” 49-3/4” 48-1/4” “A” +1/8” -0” CUT OUT Side rail *1x2 Step Block* +1/8” “C”-0” 3/4” 1-1/2” ® 12655 E. 42nd Ave. #50 Denver, CO 80239 Phone: 303.322.5570 Fax: 303.322.5568 www.pinnacle-ltg.com © 2013 Pinnacle Architectural Lighting 1 of 4 1. This product must be installed in accordance with applicable installation and electrical codes by a professional familiar with the construction and operation of the product. 2. Minimum 90ºC supply conductors. 3. All electrical connections must be performed by a certified electrician to applicable local and national electrical codes. 4. Contact Pinnacle prior to making any fixtures alterations. 5. Contact Pinnacle wit h any installation questions or field issuess. ADEO T8 Inaccessible Installation * T8 Fixture has housing extension. Read instructions to acomodate for extension. Step 3: Making the Connections Step 4: Install Fixture into Ceiling 1. Remove electrical cover, remove knockout, attach building supplied conduit. 2. Make electrical connections, recess wires into fixture cavity and attach cover. 1. After wiring the fixture and checking all connections, carefully install fixture by angling it up through drywall frame kit and rest the housing on the frame. Phone: 303.322.5570 Fax: 303.322.5568 www.pinnacle-ltg.com © 2013 Pinnacle Architectural Lighting 2 of 4 1. This product must be installed in accordance with applicable installation and electrical codes by a professional familiar with the construction and operation of the product. 2. Minimum 90ºC supply conductors. 3. All electrical connections must be performed by a certified electrician to applicable local and national electrical codes. 4. Contact Pinnacle prior to making any fixtures alterations. 5. Contact Pinnacle wit h any installation questions or field issuess. ® 12655 E. 42nd Ave. #50 Denver, CO 80239 2-1/16” ADEO Step 5: Installing Lamps T8 Inaccessible Installation * T8 Fixture has housing extension. Read instructions to acomodate for extension. For 1x4 and 2x4 1. Locate notch on lens endcap, pull down from notched side of lens to open. 2. Lens remains captive to fixture for lamp installation and maintenance. 3. When closing lens make sure to push in center of lens so lens snaps shut over lens clip. 1. When closing lens, reverse steps for opening lens. 2. Once done also push on center of lens (both sides) to engage lens to housing. Notch Notch Housing Notches ® 12655 E. 42nd Ave. #50 Denver, CO 80239 Phone: 303.322.5570 Fax: 303.322.5568 www.pinnacle-ltg.com © 2013 Pinnacle Architectural Lighting 3 of 4 1. This product must be installed in accordance with applicable installation and electrical codes by a professional familiar with the construction and operation of the product. 2. Minimum 90ºC supply conductors. 3. All electrical connections must be performed by a certified electrician to applicable local and national electrical codes. 4. Contact Pinnacle prior to making any fixtures alterations. 5. Contact Pinnacle wit h any installation questions or field issuess. ADEO T5/T8 Maintenance Sheet Figure 1 Figure 1 Figure 2 Figure 2 #8-32 Screws (holds ballast tray) Notch Access to lamps 1. Disconnect power. 2. Locate lens notch (located on one side only) and pull lens down from that side (Fig 1). 3. Lens swings open allowing access to lamps (Fig 2). 4. Lens remains captive to fixture during lamps/ballast maintenance (Fig 2). Lens Cleaning 1. Open lens (as instructed) 2. Lens remains captive to fixture during maintenance/cleaning. 3. Wipe top and bottom of lenses with Isopropyl alcohol and a clean rag (DO NOT USE AMMONIA). 4. Close by rotating and pushing lens up until it snaps in place. 1. Disconnect power. 2. To access the ballast, remove #8-32 screws (fig. 1). 3. Pull ballast tray off as shown (fig. 2) and ballast will be fully accessible. 4. Reverse step 2 prior to closing lens. 5. Close by rotating and pushing lens up until it snaps in place. Phone: 303.322.5570 Fax: 303.322.5568 www.pinnacle-ltg.com © 2013 Pinnacle Architectural Lighting 4 of 4 1. This product must be installed in accordance with applicable installation and electrical codes by a professional familiar with the construction and operation of the product. 2. Minimum 90ºC supply conductors. 3. All electrical connections must be performed by a certified electrician to applicable local and national electrical codes. 4. Contact Pinnacle prior to making any fixtures alterations. 5. Contact Pinnacle with any installation questions or field issues. ® 12655 E. 42nd Ave. #50 Denver, CO 80239 Access to ballast