T8 Inaccessible Installation - Pinnacle Architectural Lighting

advertisement
ADEO
T8
Inaccessible Installation
* T8 Fixture has housing extension. Read instructions to acomodate for extension.
Step 1:
Rough in
Step 2:
Setting up the Flange Kit
1. Build ceiling framing using Dim “A” and “B”
2. Make appropriate cut out in drywall using Dim
“A” and “C” (see dimension chart below).
3. Install flange kit.
1. Slide (snap-lock) corner angles into the
inboard side of the side rail and end/intermediate rail as shown.
2. Place assembled flange into ceiling opening and tie off to structure using tie wires (by
others) on all four corners.
1x2 Step Blocking
End/Intermediate rail
Corner angle
Drywall
Tie Wire Support
(By others)
Ceiling Bracing
Flange Kit
(By others)
+1/8”
“B” -0”
Dimension Chart
Fixture Size
Dim “A”
Dim “B”
Dim “C”
1x4
12-1/4”
49-3/4”
48-1/4”
2x2
24-1/4”
25-3/4”
24-1/4”
2x4
24-1/4”
49-3/4”
48-1/4”
“A”
+1/8”
-0”
CUT OUT
Side rail
*1x2 Step Block*
+1/8”
“C”-0”
3/4”
1-1/2”
®
12655 E. 42nd Ave. #50 Denver, CO 80239
Phone: 303.322.5570 Fax: 303.322.5568
www.pinnacle-ltg.com
© 2013 Pinnacle Architectural Lighting
1 of 4
1. This product must be installed in accordance with applicable installation and electrical codes by a professional familiar with
the construction and operation of the product.
2. Minimum 90ºC supply conductors.
3. All electrical connections must be performed by a certified electrician to applicable local and national electrical codes.
4. Contact Pinnacle prior to making any fixtures alterations.
5. Contact Pinnacle wit h any installation questions or field issuess.
ADEO
T8
Inaccessible Installation
* T8 Fixture has housing extension. Read instructions to acomodate for extension.
Step 3:
Making the Connections
Step 4:
Install Fixture into Ceiling
1. Remove electrical cover, remove knockout,
attach building supplied conduit.
2. Make electrical connections, recess wires
into fixture cavity and attach cover.
1. After wiring the fixture and checking all
connections, carefully install fixture by angling
it up through drywall frame kit and rest the
housing on the frame.
Phone: 303.322.5570 Fax: 303.322.5568
www.pinnacle-ltg.com
© 2013 Pinnacle Architectural Lighting
2 of 4
1. This product must be installed in accordance with applicable installation and electrical codes by a professional familiar with
the construction and operation of the product.
2. Minimum 90ºC supply conductors.
3. All electrical connections must be performed by a certified electrician to applicable local and national electrical codes.
4. Contact Pinnacle prior to making any fixtures alterations.
5. Contact Pinnacle wit h any installation questions or field issuess.
®
12655 E. 42nd Ave. #50 Denver, CO 80239
2-1/16”
ADEO
Step 5:
Installing Lamps
T8
Inaccessible Installation
* T8 Fixture has housing extension. Read instructions to acomodate for extension.
For 1x4 and 2x4
1. Locate notch on lens endcap, pull down from
notched side of lens to open.
2. Lens remains captive to fixture for lamp
installation and maintenance.
3. When closing lens make sure to push in center of lens so lens snaps shut over lens clip.
1. When closing lens, reverse steps for opening lens.
2. Once done also push on center of lens (both sides) to engage lens to
housing.
Notch
Notch
Housing Notches
®
12655 E. 42nd Ave. #50 Denver, CO 80239
Phone: 303.322.5570 Fax: 303.322.5568
www.pinnacle-ltg.com
© 2013 Pinnacle Architectural Lighting
3 of 4
1. This product must be installed in accordance with applicable installation and electrical codes by a professional familiar with
the construction and operation of the product.
2. Minimum 90ºC supply conductors.
3. All electrical connections must be performed by a certified electrician to applicable local and national electrical codes.
4. Contact Pinnacle prior to making any fixtures alterations.
5. Contact Pinnacle wit h any installation questions or field issuess.
ADEO
T5/T8 Maintenance Sheet
Figure 1
Figure 1
Figure 2
Figure 2
#8-32 Screws
(holds ballast tray)
Notch
Access to lamps
1. Disconnect power.
2. Locate lens notch (located on one side only) and pull lens down
from that side (Fig 1).
3. Lens swings open allowing access to lamps (Fig 2).
4. Lens remains captive to fixture during lamps/ballast maintenance
(Fig 2).
Lens Cleaning
1. Open lens (as instructed)
2. Lens remains captive to fixture during maintenance/cleaning.
3. Wipe top and bottom of lenses with Isopropyl alcohol and a clean rag
(DO NOT USE AMMONIA).
4. Close by rotating and pushing lens up until it snaps in place.
1. Disconnect power.
2. To access the ballast, remove #8-32 screws (fig. 1).
3. Pull ballast tray off as shown (fig. 2) and ballast will be fully accessible.
4. Reverse step 2 prior to closing lens.
5. Close by rotating and pushing lens up until it snaps in place.
Phone: 303.322.5570 Fax: 303.322.5568
www.pinnacle-ltg.com
© 2013 Pinnacle Architectural Lighting
4 of 4
1. This product must be installed in accordance with applicable installation and electrical codes by a professional familiar with
the construction and operation of the product.
2. Minimum 90ºC supply conductors.
3. All electrical connections must be performed by a certified electrician to applicable local and national electrical codes.
4. Contact Pinnacle prior to making any fixtures alterations.
5. Contact Pinnacle with any installation questions or field issues.
®
12655 E. 42nd Ave. #50 Denver, CO 80239
Access to ballast