We take care of it. • General Data Supply voltage Accuracy inputs Standard Time synchronisation Voltage inputs Current inputs Options • PQI-D – the flexible Design Inputs Options Memory Interface Optional interfaces • PQI-DA – the compact Design Inputs Memory Interface Optional interfaces • PQSys – the allrounder Design Inputs Options Industrial PC Memory Interface PQSys_08_2010_E_nü Installed software AC/DC 88 V … 264 V or DC 18 V ... 72 V < 0.1% voltage and currents; 24 bit resolution IEC61000-4-30 class A DCF77, GPS, IRIG-A, IRIG-B, NTP selectable for 100 V or 400 V input selectable for protection circuit 1A / 5A or metering circuit 1A /5A The PQSys devices can be connected with the interface REG-PE or REG-PED to SCADA systems via IEC 61850 or IEC 60870-5-103 protocol. 19“ rack wall mounting case panel mounting housing 4 x U, 4 x I or 8 x U for each plug in module 16 x U, 16 x I or 32 x U maximum channels per 19“ rack Binary inputs Relays outputs analog outputs (measurement transducer (-20 mA .. .0 ...+20 mA) analog inputs for temperature and additional signals current inputs for current clamps or Rogowski coils 64 MByte for each plug in module 2 x RS232 / 1 x RS485 2 x E-LAN (RS485) bus system for max. 255 devices 2 x time and trigger bus Ethernet TCP/IP; analog modem, GPRS, UMTS, two wire, four wire connection, optical-fibre Wall mounting case, DIN-rail housing 4 x U, 4 x I or 8 x U 4 binary inputs, 5 relays outputs 64 MByte 2 x RS232 / 1 x RS485 2 x E-LAN (RS485) bus system for max. 255 devices 2 x time and trigger bus Ethernet TCP/IP analog modem, GPRS, UMTS, two wire, four wire connection, optical fibre 19“ rack wall mounting case 4 x U, 4 x I or 8 x U for each plug in module 12 x U, 12 x I or 24 x U maximum channels per 19“ rack 4 x U, 4 x I or 8 x U maximum channels per wall mounting housing binary inputs relays outputs analog outputs (measurement transducer (-20 mA ... 0 ...+20 mA) analog inputs for temperature and additional signals current inputs for current clamps or Rogowski coils fix installed, robust, no rotating parts 16 GByte CF card 2 x RS232 / 1 x RS485 2 x E-LAN (RS485) bus system for max. 255 devices 2 x time and trigger bus 2 x USB 2.0 / 1 x Ethernet TCP/IP 1 x monitor, mouse and keyboard Windows XP / My-SQL database / user software WinPQ Head Office and Factory Austria and Eastern Europe Asia and Middle East Chinese Territory A. Eberle GmbH & Co. KG Aalener Straße 30/32 90441 Nuremberg/Germany A. Eberle GmbH & Co. KG Hamiltongasse 5 / A6 1140 Vienna/Austria phone +49 911 628108-0 e-mail info@a-eberle.de phone +43 1 416 93 53 e-mail alfred.nemec@a-eberle.at A. Eberle Systems Private Ltd. 113, Vardhaman Industrial complex Old Agra Road Thane West 400601 Mumbai India phone +91 22 41514034 mobile +91 98 19301301 e-mail pradeep.modi@a-eberle.de A. Eberle Shanghai Rep. Office Huichuan Rd. 88 Long (Regents Park) Building 7 / Room 3106 Shanghai / China phone +86 21 22819365 mobile +86 13524310636 e-mail dan.chen@a-eberle.de www.a-eberle.de PQSys Instantaneous Values PQSys – Instantaneous Values automatically available from Low, Medium and High-Voltage Grids • Disturbance Recorder • Power Quality Monitor • Voltage Quality according to EN 50160 • IEC 61000-4-30, Class A • Permanent Recorder • Transducer • SCADA connection according to IEC 61850 Voltage quality safely in view PQSys family: Network Analyzer, Disturbance Recorder and Transducer all in one Recorder Disturbance Recorder PQSys RMS Recorder EN 50160 Transducer MW PQSys is also available as mobile network analyzer PQ-Box 100. Area of Application The disturbance recorder and power quality analyzers of the PQSys famliy can be used on the consumer, distributor and generator side. With the function „Transnostic“ the PQSys clearly differentiate between accidental (“imported”) faults and selfcaused faults, whilst the energy supplier can document the voltage quality that he has supplied to his customers at a particular feeding point, over a freelyselectable time range. Disturbance Recorder The PQSys includes several disturbance recorders with different sampling frequencies. They differ in the level of detailing and length of recording time. The system offers a huge spectrum of trigger criterions to start recorders. Recording time and pre trigger time are free selectable. With the “retrigger function” the analyzer can adjust the recording time automatically to each disturbance. Oscilloscope Traces The instantaneous values (96 μs values) are recorded with a frequency of 10.24 kHz. This enables a fault fingerprint to be registered. RMS Recorder The RMS-recorder records with 10 ms interval time all TRMS values of voltages (line to line and line to earth), currents, real, apparent, reactive power and the frequency. Digital Channels All binary inputs can be recorded with up to 10,24 kHz. These channels can be used for recording external events (switch positions, protection relays) or to start and stop disturbance records. PQ Event Recorder All EN 50160 limit value violations, together with identification and timestamp, are recorded in the event recorder. Permanent Recorder With the continuous recorder function it is possible to record up to 3.000 different measurement values with different recording times parallel. These different recorders are possible: 200 ms; 1 sec; 3 sec; 1 min; 10 min; 15 min; 2 h. Additional to the average values are the 10 ms extreme values available. Transducer The PQSys can also be used as a multiple measurement transducer, that can supply up to eight mA outputs with over 3,000 measurement values. Auto Reporting The system automatically signals fault records and sends these on to e-mail addresses and fax machines. Weekly reports or yearly statistics are automatically created and archived. Analog Input The PQSys can be equipped with 4 additional analog inputs. With these inputs (-20 mA…0…+20 mA; 4 mA ... 20 mA or 0…10 V) it is possible to record temperature or other additional signals parallel to voltage and current inputs. Instantaneous values ...