page 1
WARNING
Door
strike
+
NO
COM
NO
COM
+
2
_
1
See note below
A
1
2
-+
NO
COM
Extra
handsets
NOTES:
Power Supply
1. Only one 12V DC Power Supply is typically needed to power the
system.
2. Power can be connected to any component in the system.
3. The diagram shows the 12V Battery Supply of gate motor
connected to the entry panel to power the system.
4. If power is being connected to the handset use either a mains adapter
with a DC jack compatible with the socket provided (A) or connect
12V-14V DC to the terminals (B).
Auxiliary Output/potential-free Normally-Open
- Gate pedestrian opening
- Pillar-Light control
- Entrance light control
See note below
B
2
_
1
1
2
-+
NO
COM
Handset
If the gate trigger wire is connected to a potential-free contact (NO or COM) on the entry panel, the gate can be opened by joining
the NO and COM terminals together.
For additional security it is advisable to wire to the auxiliary terminals on the handset or connect the POLOswitch in the gate motor.
Potential-free
Normally-Open
contact to
activate gate
motor etc.
TRG COM
+
NO
COM
+
NO
COM
Battery supply
2
_
2
_
Power supply
for door strike
1
-+
NO
COM
-+
1
2
NO
COM
1
2
Entry panel
1
Wiring Diagram
Commissioning
Entry Panel Selector Switch and Volume Control



If the system has only one Entry Panel set the selector switch (A) to the upper position or
(1)
If there are two Entry Panels set the selector switch on the one panel to the upper position
(1) and on the other panel to the lower position (2)
When adjusting the speech volume start by setting the control knob (B) approximately
75% of full volume. Clockwise rotation increases the volume. Having set the volume
adjustment on all the handsets to the same volume, optimise the speech volume at the
Entry Panel(s)
FIGURE 1. ENTRY PANEL SELECTOR SWITCH AND VOLUME CONTROL
page 2
facebook.com/CenturionSystems
YouTube.com/CenturionSystems
Subscribe to the newsletter: www.CentSys.com/Subscribe
Sharecall: 0860 236 887
Head Office: +27 11 699 2400
Sharecall Technical Support 0861 003 123 or
+27 11 699 2481
from 07h00 to 18h00 (GMT+2)
(Sharecall numbers applicable when dialed from within South Africa only)
DOC1163G02_12012015
www.CentSys.com
Download