POLOphone Entry Panel Wiring Diagram & Commissioning Procedure TM Visit www.CentSys.com for the full range of products from Centurion Systems (Pty) Ltd page 1 WARNING Door strike + NO COM NO COM + 2 _ 1 See note below A 1 2 -+ NO COM Extra handsets NOTES: Power Supply 1. Only one 12V DC Power Supply is typically needed to power the system. 2. Power can be connected to any component in the system. 3. The diagram shows the 12V Battery Supply of gate motor connected to the entry panel to power the system. 4. If power is being connected to the handset use either a mains adapter with a DC jack compatible with the socket provided (A) or connect 12V-14V DC to the terminals (B). Auxiliary Output/potential-free Normally-Open - Gate pedestrian opening - Pillar-Light control - Entrance light control See note below B 2 _ 1 1 2 -+ NO COM Handset If the gate trigger wire is connected to a potential-free contact (NO or COM) on the entry panel, the gate can be opened by joining the NO and COM terminals together. For additional security it is advisable to wire to the auxiliary terminals on the handset or connect the POLOswitch in the gate motor. Potential-free Normally-Open contact to activate gate motor etc. TRG COM + NO COM + NO COM Battery supply 2 _ 2 _ Power supply for door strike 1 -+ NO COM -+ 1 2 NO COM 1 2 Entry panel 1 Wiring Diagram Commissioning Entry Panel Selector Switch and Volume Control If the system has only one Entry Panel set the selector switch (A) to the upper position or (1) If there are two Entry Panels set the selector switch on the one panel to the upper position (1) and on the other panel to the lower position (2) When adjusting the speech volume start by setting the control knob (B) approximately 75% of full volume. Clockwise rotation increases the volume. Having set the volume adjustment on all the handsets to the same volume, optimise the speech volume at the Entry Panel(s) FIGURE 1. ENTRY PANEL SELECTOR SWITCH AND VOLUME CONTROL page 2 facebook.com/CenturionSystems YouTube.com/CenturionSystems Subscribe to the newsletter: www.CentSys.com/Subscribe Sharecall: 0860 236 887 Head Office: +27 11 699 2400 Sharecall Technical Support 0861 003 123 or +27 11 699 2481 from 07h00 to 18h00 (GMT+2) (Sharecall numbers applicable when dialed from within South Africa only) DOC1163G02_12012015 www.CentSys.com