05−1692 DIAGNOSTICS − POWER DOOR LOCK CONTROL SYSTEM 05AFX−01 DOUBLE LOCK FUNCTION DOES NOT OPERATE PROPERLY CIRCUIT DESCRIPTION All the doors except the back door have the double locking system. This system is set or unset by the door opening relay assy (double lock control relay). When the door opening relay assy receives a request signal (See page 73−1) that the double locking system is set or unset from the wireless transmitter, it drives the double lock motor in each door lock according to the condition of all the double lock position switches, this causing the double locking system to set or unset. LAND CRUISER PRADO REPAIR MANUAL (RM990E) 05−1693 − DIAGNOSTICS POWER DOOR LOCK CONTROL SYSTEM WIRING DIAGRAM D7 Door Opening Relay Assy (Double Lock Control Relay) Instrument Panel Junction Block Assy 9 IE 4 IL G−W Engine Room Relay Block Assy ECU−B 1 2 W−L 2 2 2 W−R 2 G−W 1 W−R 7 +B CPUB Junction Block No.1 4 1D 4 1A 2 SHORT PIN 1 26 IJ 4 IB B W−R DR/LCK 2 2 1 Battery D20 Front Door w/ Motor Lock Assy RH DLSR W−B J27 J/C 4 10 E B B UNDL W−B W−B B J28 J/C B 4 J24 J/C W−B IA1 A 5 E DLSR DL W−B A W−B 4 R−L 3 B−R UNDL A G 2 R−L 1 B−R 3 BB1 11 IO1 9 IO1 10 IO1 11 IA1 9 IA1 10 IA1 D22 Rear Door w/ Motor Lock Assy LH 6 9 G−B DLSR BA1 4 4 G−R 3 BA1 DL 10 BA1 E 5 W−B 3 L−W BA1 UNDL DLSR W−B 6 6 E W−B DL UNDL A J12 J/C G−Y 5 L−R L−R 3 L−W L−W 4 G 6 5 G−R 2 G−R 1 L−W W−B 6 BB1 4 BB1 5 BB1 DLPD ACTS ACTR L−R L−R DLPP L−W L−W L−W L−R 12 G−B L−R B B A DLPL J23 J/C L−W A B D23 Rear Door w/ Motor Lock Assy RH IN A G−Y D19 Front Door w/ Motor Lock Assy LH IO1 W−B DL 9 A G−R 11 DLPR L−R L−W 14 GND IJ LAND CRUISER PRADO REPAIR MANUAL (RM990E) B64717 05−1694 DIAGNOSTICS − POWER DOOR LOCK CONTROL SYSTEM INSPECTION PROCEDURE 1 (a) INSPECT WIRELESS DOOR LOCK OPERATION Check that the doors can be normally locked and unlocked by the wireless operation. NG GO TO WIRELESS DOOR CONTROL SYSTEM (See page 05−1699) OK 2 (a) INSPECT FUSES Inspect the ECU−B fuse and R/LCK fuse. (See page 68−1) NG OK LAND CRUISER PRADO REPAIR MANUAL (RM990E) REPLACE FUSES 05−1695 DIAGNOSTICS 3 − POWER DOOR LOCK CONTROL SYSTEM INSPECT DOOR LOCK ASSY (EXCEPT BACK DOOR LOCK) (a) Front Door w/Motor Lock Assy LH: Inspect operation of the double lock motor. (1) Apply battery voltage and set the door lock motor to LOCK. Standard: Measurement Condition Specified Condition Battery positive (+) ® Terminal 4 Battery negative (−) ® Terminal 3 Lock Battery positive (+) ® Terminal 3 Battery negative (−) ® Terminal 4 Unlock (2) Lock Apply battery voltage and inspect operation of the double lock motor. Standard: Unlock Measurement Condition Specified Condition Battery positive (+) ® Terminal 2 Battery negative (−) ® Terminal 1 Double locking system is Set Battery positive (+) ® Terminal 1 Battery negative (−) ® Terminal 2 Double locking system is Unset (3) B64707 Check that the doors cannot be unlocked by operating the control cable while the double locking system is set. (4) Inspect the double lock position switch continuity. Standard: Terminal No. 5Û6 LAND CRUISER PRADO REPAIR MANUAL (RM990E) Double Lock Position Specified Condition SET Continuity UNSET No continuity 05−1696 − DIAGNOSTICS (b) POWER DOOR LOCK CONTROL SYSTEM Front Door w/Motor Lock Assy RH: Inspect operation of the double lock motor. (1) Apply battery voltage and set the door lock motor to LOCK. Standard: Measurement Condition Specified Condition Battery positive (+) ® Terminal 2 Battery negative (−) ® Terminal 1 Lock Battery positive (+) ® Terminal 1 Battery negative (−) ® Terminal 2 Unlock (2) Apply battery voltage and inspect operation of the double lock motor. Standard: Unlock Lock Measurement Condition Specified Condition Battery positive (+) ® Terminal 4 Battery negative (−) ® Terminal 3 Double locking system is Set Battery positive (+) ® Terminal 3 Battery negative (−) ® Terminal 4 Double locking system is Unset (3) B64708 Check that the doors cannot be unlocked by operating the control cable while the double locking system is set. (4) Inspect the double lock position switch continuity. Standard: Terminal No. 9 Û 10 LAND CRUISER PRADO REPAIR MANUAL (RM990E) Double Lock Position Specified Condition SET Continuity UNSET No continuity 05−1697 DIAGNOSTICS (c) − POWER DOOR LOCK CONTROL SYSTEM Rear Door w/Motor Lock Assy LH: Inspect operation of the double lock motor. (1) Apply battery voltage and set the door lock motor to LOCK. Standard: Measurement Condition Specified Condition Battery positive (+) ® Terminal 2 Battery negative (−) ® Terminal 1 Lock Battery positive (+) ® Terminal 1 Battery negative (−) ® Terminal 2 Unlock (2) Apply battery voltage and inspect operation of the double lock motor. Standard: Lock Unlock Measurement Condition Specified Condition Battery positive (+) ® Terminal 4 Battery negative (−) ® Terminal 3 Double locking system is Set Battery positive (+) ® Terminal 3 Battery negative (−) ® Terminal 4 Double locking system is Unset (3) B64705 Check that the doors cannot be unlocked by operating the control cable while the double locking system is set. (4) Inspect the double lock position switch continuity. Standard: Terminal No. 9 Û 10 LAND CRUISER PRADO REPAIR MANUAL (RM990E) Double Lock Position Specified Condition SET Continuity UNSET No continuity 05−1698 − DIAGNOSTICS (d) POWER DOOR LOCK CONTROL SYSTEM Rear Door w/Motor Lock Assy RH: Inspect operation of the double lock motor. (1) Apply battery voltage and set the door lock motor is LOCK. Standard: Measurement Condition Specified Condition Battery positive (+) ® Terminal 4 Battery negative (−) ® Terminal 3 Lock Battery positive (+) ® Terminal 3 Battery negative (−) ® Terminal 4 Unlock (2) Apply battery voltage and inspect operation of the double lock motor. Standard: Unlock Lock Measurement Condition Specified Condition Battery positive (+) ® Terminal 2 Battery negative (−) ® Terminal 1 Double locking system is Set Battery positive (+) ® Terminal 1 Battery negative (−) ® Terminal 2 Double locking system is Unset (3) B64706 Check that the doors cannot be unlocked by operating the control cable while the double locking system is set. (4) Inspect the double lock position switch continuity. Standard: Terminal No. 5Û6 NG Double Lock Position Continuity UNSET No continuity REPLACE DOOR LOCK ASSY OK REPLACE DOOR OPENING RELAY ASSY (DOUBLE LOCK CONTROL RELAY) LAND CRUISER PRADO REPAIR MANUAL (RM990E) Specified Condition SET