COOPER LIGHTING - SURE-LITES DESCRIPTION Catalog # The fastest and easiest mounting cylinder unit available. The SLC Series is a totally solid-state and self-contained emergency lighting system. The sleek architecturally designed heads blend perfectly with the most sophisticated decor. The SLC Series blends well with the decor in offices, lobbies, restaurants, stores, public lodgings and other areas where decor must reflect architectural appeal and beauty. Type Project Comments Prepared by Date The SLC Series is available with the capability of powering remote fixtures and exit signs. S P E C I F I C AT I O N F E AT U R E S Electronic Dual Voltage Input 120/277 VAC, 60 Hz Universal J-Box Mounting Pattern Warranty Unit – 1 year Line-latching White Finish Battery – 5 year pro-rata Solid-state Voltage Limited Charger Solid-state Switching Battery Sealed Lead Calcium, Recombination Head/Lamp Data Single or Double Front Mounted Low Voltage Disconnect Maintenance Free, Long Life Brownout Circuit Full Recharge Time, 24 hrs. (max.) Overload/Short Circuit Protection Glare-Free Lens Fully Adjustable Remote Capability High Impact – Thermoplastic Polarized Battery Terminals White Finish Test Switch/Power Indicator Light Code Compliance UL 924 Listed Housing Construction 18 Gauge Die-Formed Steel Life Safety NFPA 101 NEC/OSHA Knockout, Conduit or Cord Set Most State and Local Codes 81 /2" [21 6m m] 23 1/4" [591mm] maximum 11 1/4" [286mm] SLC SERIES 2 1/8" [54mm] 2 1/4" [57mm] LARGE CYLINDER HEAD 2 1/4" [57mm] 4 1/2" [114mm] EMERGENCY LIGHT 4 1/2" [114mm] 5 1/2" [140mm] 11" [279mm] 5 1/2" [140mm] 11" [279mm] Emergency Lighting E L E C T R I C A L R AT I N G S Lamp Information R a t e d W a t t a g e to 87 1/2% of Rated D.C. Voltage Model No. of Heads SLC1 SLC1H SLC2 SLC2H 1 1 2 2 DC Voltage 6 6 6 6 1 1/2 Hours 2 Hours 10.8 27 18 54 7.2 24 15 48 3 Hours 4 Hours Type Wattage Number – 18 10 36 – 14 8 28 Incandescent Incandescent Incandescent Incandescent 9 9 9 9 29-84 29-84 29-84 29-84 O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: SLC1V O p t i o n s (add as suffix) Model Number SLC1 SLC1H SLC2 SLC2H A c c e s s o r i e s (order separately) A1=Ammeter WG5=Wire Guard for SCL1, SLC1H TDM=Time Delay Monitor WG6=Wire Guard for SLC2, SLC2H E N E R G Y D AT A SLC1 Input Current (Max.): 120V= .08A 277V= .04A SLC1H, SLC2, SLC2H Input Current (Max.): 120V= .12A 277V= .05A V1=Voltmeter Alternate Lamps: Consult Cooper Lighting Representative Other Options: Consult Cooper Lighting Representative COOPER LIGHTING Note: 1Provision for one meter only. ADX041158 ® S L C SERIES PHOTOMETRICS Horizontal Distribution Ve r t i c a l D i s t r i b u t i o n 10 FEET LEFT 10 FEET LEFT 1FC 0 0.5 0.3 0.2 0.1 LAMP AXIS 1FC 0 FEET RIGHT 10 0.5 0.3 0.2 0.1 LAMP AXIS FEET RIGHT 10 0 10 20 30 40 50 60 70 0 FEET FROM LAMP (Measured on axis) Lamp No. 29-84 Initial Lumens – 29-84 @ 132 10 20 30 40 50 60 70 FEET FROM LAMP (Measured on axis) Lamp No. 29-84 T E C H N I C A L D AT A Heads Line-Latched Brownout Circuit The lamp housing is constructed of impact-resistant injection molded thermoplastic with white finish. The three dimensional swivel assembly permits 80° aiming adjustment from vertical and approximately 358° rotation. The placement is secured with a lockable pivot mounted on a rotating base ring. Sure-Lites’ line-latched electronic circuitry makes installation easy and economical. A labor efficient AC-activated load switch prevents the lamps from turning on during installation to a nonenergized AC circuit. Line-latching eliminates the need for a contractor’s return to a job site to connect the batteries when the building’s main power is permanently turned on. The brownout circuit in SureLites’ units monitors the flow of AC current to the unit and activates the emergency lighting system when a predetermined reduction of AC power occurs. This dip in voltage will cause most ballasted fixtures to extinguish causing loss of normal lighting even though a total power failure has not occurred. Solid-State Charger S o l i d - S t a t e Tr a n s f e r Supplied with a 120/277 VAC, voltage regulated solid-state charger. Immediately upon restoration of AC current after a power failure, the charger provides a high charge rate. The charge circuit reacts to the condition of the battery and alters the rate of charge in order to maintain peak battery capacity and maximize battery life. Solid-state construction recharges the battery following a power failure in accordance with UL 924. The unit incorporates a solidstate switching transistor which eliminates corroded and pitted contacts or mechanical failures associated with relays. The switching circuit is designed to detect a loss of AC voltage and automatically energizes the lamps. Upon restoration of the AC power, the emergency lamp(s) will switch off and the charger will automatically recharge the battery. Lamps Designed specifically for emergency lighting applications, the PAR 36 sealed beam type design insures optimum glarefree trapezoidal light distribution along with horizontal and vertical adjustment by rotating the lens within the housing. Housing The rugged 18 gauge die-formed steel faceplate is finished with an attractive corrosion-resistant polyester powder coat painted front and a complementary body. Cabinet has side knockout for conduit entry for AC/DC wiring connections and universal mounting pattern. Single molex connector makes all wiring connections between backplate and removable faceplate. Overload and Short Circuit Protection The solid-state overload monitoring device in the DC circuit disconnects the lamp load from the battery should excessive wattage demands be made and automatically resets when the overload or short circuit is removed. This overload current protective feature eliminates the need for fuses or circuit breakers for the DC load. L o w Vo l t a g e D i s c o n n e c t Te s t S w i t c h / P o w e r I n d i c a t o r Light Conveniently located Test Switch allows for manual verification of proper operation of the transfer circuit and emergency lamps. The Power Indicator Light provides visual assurance that the AC power is on. Sealed Lead Calcium Battery The fully sealed, long life, maintenance free lead calcium battery is ideal for emergency lighting applications. These recombinant cycle batteries typically provide eight to ten years of life and may be operated in any position. Warranty All Sure-Lites’ units are backed by a firm one year warranty against defect in material and workmanship (excluding lamps). Maintenance free, long life, sealed lead calcium batteries carry a five-year pro-rata warranty. When the battery’s terminal voltage falls below 80% of the rated voltage, the low voltage circuitry disconnects the lighting load. The disconnect remains in effect until normal utility power is restored, preventing deep battery discharge. N O T E S : See option/accessories or technical sections for additional detailed product data. Specifications and Dimensions subject to change without notice. Customer First Center 1121 Highway 74 South, Peachtree City, GA 30269 770.486.4800 Fax 770.486.4801 ADX041158