TruGroove - Ledalite

advertisement
TruGroove
Installation Instructions
ID-39_TruGroove_T-Grid
T-Grid Ceiling
Standalone & Continuous Run Installation
System Overview
Prepare Fixtures/Reference Layout Drawings
These instructions review how to install TruGroove recessed fixtures in T-Grid Ceilings.
For continuous run lengths, please refer to layout drawings supplied by Philips Ledalite in
conjunction with these installation instructions. The graphic below shows the components
required to install a run of TruGroove fixtures in T-Grid ceilings.
Arrange boxed fixtures on floor in specified mounting locations, based on supplied layout drawings.
Remove fixtures from boxes. Remove plastic from fixtures. Match up each fixture and lens based on
the spec tag and ID number labelled on each fixture box for the specified run.
TruGroove joint kit(s)*
TruGroove hangar kit(s)*
• Joiner Aligners (x2)
• Joining Brackets (x2)
• Hex Bolts (x4)
• Bracket (x4)
• Screws (x8)
*NOTE:
One (1) kit required
for each module
*NOTE:
One (1) kits required per fixture.
Two (2) kits required per corner.
MODULE #2
Tools Required: Philips screwdriver, 3/8" nut driver.
MODULE #1
EXTERIOR LENS KIT
- VARIABLE LENGTHS
!
ATTENTION: Install in accordance with national and local building and electrical codes.
© 2014 Philips Ledalite
Phone: 604.888.6811
Fax: 800.665.5332
Web: ledalite.com
Page 1
0412
TruGroove
T-Bar Ceiling
T-Barprep
Ceiling prep
1
Straight run detail
Grid suspension cable
T-Bar grid
Installation Instructions
ID-39_TruGroove_T-Grid
Install Mounting Brackets
2
Install Fixture Above T-Bar Grid
9/16˝ Grid 19/316
Height
1 3/4˝ Height
/4˝ Grid
9/16˝ Grid 19/11
˝ Height
1 11/16˝ Height
16/˝16Grid
9/16˝ Grid 19/116
Height
1 1/2˝ Height
/2˝ Grid
T-Bar Ceiling prep
T-Bar Ceiling
T-Bar
prep
Ceiling prep
Grid
suspension
cable
4"
4"
9/16˝ Grid 19/116
˝ ˝Grid
Height
1 1/16
- 5˝/16
Height
˝ Tegular
- 5/16˝ Tegular
/16
9/16˝ Grid 19/116
Height
1 1-/25˝/16
Height
˝ Tegular
- 5/16˝ Tegular
/2˝ Grid
15/16˝ Grid 15
1 /11
˝ Height
1 11/16˝ Height
16/˝16Grid
Install Joiner Aligners
4
15/16˝ Grid 1 1/2˝ Height
15/16˝ Grid 1 115
Height
˝ Grid 1 1/2˝ Height 15/16˝ Grid 1 1/2˝ Height
/2/˝16
15/16˝ Grid 1 3/8˝ Height
15/16˝ Grid 1 315
Height
˝ Grid 1 3/8˝ Height 15/16˝ Grid 1 3/8˝ Height
/8/˝16
15/16˝ Grid 1 3/16˝ Height
15/16˝ Grid 1 315
˝ Height
˝ Grid 1 3/16˝ Height 15/16˝ Grid 1 3/16˝ Height
/16
/16
Install T-Grid mounting brackets to required height.
4" Fixture
4" modules require 44"brackets.
NOTE:
Corner modules require 8 brackets.
Complete Wiring and
Connect Fixtures
6
Install the joiner fixture into the T-Bar Grid
from above. Complete wiring and slide the
fixtures together.
Install the first fixture (or Standalone Unit)
from above the T-Bar Grid.
Install supplied side attachment brackets
with 3/8” nut driver.
Secure the Fixture to the Grid
7
Secure the fixture to the T-Bar grid.
Phone: 604.888.6811
Fax: 800.665.5332
Web: ledalite.com
Install Power Drop
8
Install power drop at desired location.
For continuous runs, finish installing run
first and then secure to the T-Bar grid.
ATTENTION: Install in accordance with national and local building and electrical codes.
© 2014 Philips Ledalite
If corners are required, install the corner
module first from above the T-Bar grid.
For standalone unit installation, skip to step 7.
Install Mounting Brackets
NOTE: In the final continuous run
module, fully insert the joiner aligner,
tap to beyond 50%.
!
3b
15/16˝ Grid 15
1 /116
Height
1 1/2˝ Height
/2˝ Grid
15/16˝ Grid 15
1 /316
Height
1 3/8˝ Height
/8˝ Grid
15/16˝ Grid 15
1 /316
˝ ˝Grid
Height
1 3/16˝ Height
/16
9/16˝ Grid 1 3/4˝ Height
9/16˝ Grid 1 3/94/˝16
9/16
5//416
1/916
Height
˝ Grid 1 3/49˝/16
Height
˝ Grid
1˝-3Grid
˝ Height
/16
˝ Grid 1 1/916
˝ Height
˝ 1Tegular
˝ Height
˝ Grid 1-15/16
Tegular
- 5/916
˝ ˝Tegular
Grid 1 1/16˝ Height - 5/16˝ Tegular
/16
/16˝˝Height
/16
9/16˝ Grid 1 11/16˝ Height
9/16˝ Grid 1 119//16
9/˝16
9/˝16Tegular
Grid 1 11/16
Height
Grid9/116-11
/16˝ Height
˝ Grid 1 91/16
˝5Grid
Tegular
1 1/92/˝16Height
˝ Grid 1- 51//16
Tegular
- 5/16
˝ Grid 1 1/2˝ Height - 5/16˝ Tegular
16˝˝ Height
2˝ ˝Height
2˝˝Height
9/16˝ Grid 1 1/2˝ Height
9/16˝ Grid 1 1/92/˝16
9//16
15/1
15//16
Height
˝ Grid 1 1/215
˝ Height
Height
1 11
Grid 1 11/16˝ Height 15/16˝ Grid 1 11/16˝ Height
/16˝ Grid 1 11
2˝ Height
16˝˝Grid
161˝/Grid
16˝ Height
5
In the joining fixture install the joiner
aligners in the trim extrusion to
approximately halfway.
3
T-Bar Ceiling prep
Corner detail
Install main Ts, 4" on center for all grid
conditions. Ensure grid suspension4"
cables
are positioned a minimum 12" from fixture/
corner module ends. For continuous row
lengths, refer to supplied layout drawings.
Add 1/4" to the overall housing length
indicated on your layout drawings. Position
the cross T.
T-Grid Ceiling
Standalone & Continuous Run Installation
Page 2
0412
TruGroove
Install Wire Access Covers
9
Installation Instructions
T-Grid Ceiling
Standalone & Continuous Run Installation
ID-39_TruGroove_T-Grid
Install Seismic Restraints
Install Lamps (Fluorescent Only)
10
Install wire access covers to close the fixture.
11
Install seismic restraints according to local
building code requirements.
At joint locations, tuck wires inside the
housing and secure the lampholder brackets
using supplied hardware. Ensure brackets
sit flush with the bottom reflectors for a
proper lamp fit.
Install Flush Snap In Lens
12
Install lamps if required. LEDs are factory
pre-installed.
NOTE: lamps are staggered in some
configurations.
Install Regressed Lens
12b
13
13b
OR
Standalone Units: Lenses are supplied
in 2, 4, or 8’ lengths.
Install “snap-in” flush lenses into the fixture.
Continuous Runs: Lenses are pre-cut to a
maximum of 8’ lengths and are specific to
run lengths. Consult layout drawings for
placement.
!
Standalone Units: Lenses are supplied
in 2’, 4’, or 8’ lengths.
Continuous Runs: Lenses are pre-cut to a
maximum of 8’ lengths and are specific to
run lengths. Consult layout drawings for
placement.
ATTENTION: Install in accordance with national and local building and electrical codes.
© 2014 Philips Ledalite
Phone: 604.888.6811
Angle lens to insert into fixture.
Lay lens on aluminum extrusion flange.
Fax: 800.665.5332
Web: ledalite.com
Page 3
0412
Download