1 2 3 4 5 6 ABBREVIATIONS LEGEND (Not all symbols listed below are used on these drawings) SEE MECHANICAL EQUIPMENT SCHEDULE AFF ABOVE FINISHED FLOOR MIN MINIMUM AFG ABOVE FINISHED GRADE MLO MAIN LUGS ONLY ANN ANNUNCIATOR MTS MANUAL TRANSFER SWITCH ARF ABOVE RAISED FLOOR NC NORMALLY CLOSED B F C B F NORMALLY OPEN NTS NOT TO SCALE CABLE TELEVISION OC ON CENTER CB CIRCUIT BREAKER OFCI OWNER FURNISHED, CONTRACTOR INSTALLED CCTV CLOSED CIRCUIT TELEVISION OFOI OWNER FURNISHED, OWNER INSTALLED (E) EXISTING OSWF ON SITE WORK FORCE EM EMERGENCY PB PULL BOX EMDC EMERGENCY MAIN DISTRIBUTION CENTER SB STAND-BY EP EXPLOSION PROOF SDC SUB-DISTRIBUTION CENTER EPO EMERGENCY POWER OFF TP TAMPER PROOF EVO EMERGENCY VENTILATION ON/OFF TVSS TRANSIENT VOLTAGE SURGE SUPPRESSER EWC ELECTRIC WATER COOLER TYP TYPICAL FA FIRE ALARM UF UNDER FLOOR G GROUND UG UNDER GROUND GCP GENERATOR CONTROL PANEL UON UNLESS OTHERWISE NOTED GFI GROUND FAULT INTERRUPTING UPS UNINTERRUPTABLE POWER SUPPLY HOA HAND OFF AUTOMATIC V VOLTS IG ISOLATED GROUND VFD VARIABLE FREQUENCY DRIVE MAX MAXIMUM W/ WITH MCB MAIN CIRCUIT BREAKER W/O WITHOUT MCC MOTOR CONTROL CENTER WP WEATHER PROOF MDC MAIN DISTRIBUTION CENTER XFMR TRANSFORMER 96" (8'-0") UON CATV MD F F NOTE: ALL DEVICES INDICATED TO BE INSTALLED AT DIFFERENT MOUNTING HEIGHTS AND LOCATED WITHIN ONE STUD SPACE FROM EACH OTHER SHALL ALIGN VERTICALLY, ON THE SAME SIDE OF THE STUD. WHERE WALL MOUNTED TELEPHONES OCCUR OVER LIGHT SWITCHES, VOLUME CONTROLS, ETC. OFFSET ONE STUD SPACE. CONTROL PANELS TC T ANN W 1 IC 2 ZAM S D CB F M S S V E S E PB P P PC P F WP F BUSHING CONDUIT FINISHED FLOOR CABLE TRAY TYPICAL DEVICE MOUNTING HEIGHTS GROUND LUG NO SCALE NOTES: 1. HEIGHTS SHOWN ARE TYPICAL TO CENTERLINE OF BOX UNLESS NOTED OTHERWISE. 2. WHERE EVER DEVICES ARE INDICATED TO BE ABOVE DOORS, DEVICE SHALL BE CENTERED BETWEEN TOP OF DOOR TRIM AND CEILING LINE. 3. MOUNTING HEIGHTS SHOWN ON ARCHITECTURAL ELEVATIONS SHALL GOVERN OVER THOSE SHOWN ABOVE. NO SCALE 16143.1 ~ ~ ~ ~ ~ ~ ~ ~ 1 UH E EXISTING TO REMAIN KITCHEN/OWNER/MEDICAL EQUIPMENT REFERENCE R EXISTING TO BE REMOVED MECHANICAL EQUIPMENT REFERENCE RL EXISTING TO BE RELOCATED ER EXISTING TO REMAIN - REPLACE DEVICE ~ ~ KEY NOTE REFERENCE 3" ~ ~ CEILING ~ ~ 1 DESCRIPTION REQUEST TO EXIT DEVICE MOUNT CENTERED ON DOORS APPROXIMATLEY 12" ABOVE DOOR FRAME MAGNETIC DOOR LOCK (BY OTHERS) 1/2" C. CARD READER 4"X4" J-BOX W/SINGLE GANG MUD RING. REFER TO FLOOR PLAN FOR LOCATION LOCKSET TECHNOLOGY LEGEND 48" AFF 48" AFF 48" AFF Imaging Suite Fit-out & Underground Power Feed FLUSH MOUNT DOOR CONTACT 1/2" C. FLUSH MOUNT DOOR CONTACT ELECTRIC STRIKE (BY OTHERS) 3" 3/4" C. CARD READER 4"X4" J-BOX W/SINGLE GANG MUD RING. REFER TO FLOOR PLAN FOR LOCATION CL CL C 1/2" CONDUIT (STUBBED BEHIND DRYWALL REFER TO NOTE 3) REQUEST TO EXIT DEVICE MOUNT CENTERED ON DOORS APPROXIMATLEY 12" ABOVE DOOR FRAME 3" 1/2" C. CL 1/2" C. (STUBBED BEHIND DRYWALL) 1/2" C. FLUSH MOUNT DOOR CONTACT LOCKSET CEILING 1/2" C. (STUBBED BEHIND DRYWALL) 3/4" C. CARD READER 4"X4" J-BOX W/SINGLE GANG MUD RING. REFER TO FLOOR PLAN FOR LOCATION LOCATE BOX IN ATTIC ABOVE ROOMS E201 OR E202, WHICHEVER IS CLOSER LOCATE BOXES IN ATTIC ABOVE ROOMS E201 OR E202, WHICHEVER IS CLOSER 1/2" CONDUIT (STUBBED BEHIND DRYWALL REFER TO NOTE 3) 3/4" C. TO CABLE TRAY ATTIC LEVEL 120 VAC MAGLOCK POWER SUPPLY (BY OTHERS) LOCATE BOX IN ATTIC ABOVE ROOMS E201 OR E202, WHICHEVER IS CLOSER 1/2" CONDUIT (STUBBED BEHIND DRYWALL REFER TO NOTE 3) REQUEST TO EXIT DEVICE MOUNT CENTERED ON DOORS APPROXIMATLEY 12" ABOVE DOOR FRAME 16111.1 3/4" C. TO CABLE TRAY ATTIC LEVEL CEILING 12-23-98 3/4" C. TO CABLE TRAY ATTIC LEVEL (Not all symbols listed below are used on these drawings) SYMBOL CONDUIT-TO-CABLE TRAY CONDUIT CONNECTION 3-27-07 REFERENCE SYMBOLS LEGEND DESCRIPTION PANIC HARDWARE CSU PROJECT #09-059 CL COLORADO STATE UNIVERSITY FOOTHILLS CAMPUS FORT COLLINS, CO ELECTRIC STRIKE (BY OTHERS) EMERGENCY DOOR RELEASE 48" AFF DATE MARK (YYYY-MM-DD) 2011-01-07 2011-03-04 2011-05-11 2011-10-28 (Not all symbols listed below are used on these drawings) SYMBOL DESCRIPTION TELEPHONE TERMINAL CABINET # DESCRIPTION KEYPAD 1 . SECURITY JUNCTION BOX (SJB) SHALL BE 6X6x6 WITH SCREW COVER. 1 . SECURITY JUNCTION BOX (SJB) SHALL BE 6X6x6 WITH SCREW COVER. 1 . SECURITY JUNCTION BOX (SJB) SHALL BE 6X6x6 WITH SCREW COVER. DOOR CONTACT 2 . ENCLOSURE AND CONDUIT TO BE PROVIDED BY ELECTRICAL CONTRACTOR. 2 . ENCLOSURE AND CONDUIT TO BE PROVIDED BY ELECTRICAL CONTRACTOR. 2 . ENCLOSURE AND CONDUIT TO BE PROVIDED BY ELECTRICAL CONTRACTOR. 3 . DOOR HEADER CONDUIT SHALL BE STUBBED TO JUST ENTER HEADER FRAME 3" TO 4" FROM OPENING SIDE OF DOOR. 3 . DOOR HEADER CONDUIT SHALL BE STUBBED TO JUST ENTER HEADER FRAME 3" TO 4" FROM OPENING SIDE OF DOOR. 3 . DOOR HEADER CONDUIT SHALL BE STUBBED TO JUST ENTER HEADER FRAME 3" TO 4" FROM OPENING SIDE OF DOOR. 4 . IF CONDUIT IS REQUIRED, INSTALL BY APPLICABLE CODE AND AUTHORITY HAVING JURISDICTION (AHJ). 4 . IF CONDUIT IS REQUIRED, INSTALL BY APPLICABLE CODE AND AUTHORITY HAVING JURISDICTION (AHJ). 4 . IF CONDUIT IS REQUIRED, INSTALL BY APPLICABLE CODE AND AUTHORITY HAVING JURISDICTION (AHJ). ELECTRIC DOOR STRIKE TELEVISION OUTLET EH ELECTRIC HINGE CLOCK OUTLET (D = DOUBLE SIDED) EP ELECTRIC POWER TRANSFER EMERGENCY EXIT BUTTON RX REQUEST TO EXIT S PAGING SYSTEM SPEAKER PS POWER SUPPLY S PAGING SYSTEM HORN (HIGH OUTPUT) ML MAGNETIC DOOR LOCK S PAGING SYSTEM SPEAKER, SURFACE MOUNT GB GLASS BREAK DETECTOR (WALL MOUNTED) SECURITY CAMERA, (1) CAT5E, DEVICE BY OWNER GB GLASS BREAK DETECTOR (CEILING MOUNTED) PROJECTOR MD MOTION DETECTOR (WALL MOUNTED) IC INTERCOM STATION MD MOTION DETECTOR (CEILING MOUNTED) VC VOLUME CONTROL DA DURESS ALARM PROJ M SECURE AREA KP ES D SECURE AREA TELEPHONE OR DATA OUTLET (# = NUMBER OF CAT6 CABLES) TELEPHONE/POWER POLE C SECURE AREA CARD READER EL TP FLOOR LINE CR ELECTRIC DOOR LOCK W FLOOR LINE SECURITY CONTROL PANEL TELEPHONE, WALL MOUNT (# = NUMBER OF CAT6 CABLES) # FLOOR LINE TELEPHONE TERMINAL BACKBOARD TELEPHONE OR DATA OUTLET, FLOOR MOUNTED (# = NUMBER OF CAT6 CABLES) # B SYMBOL SEC WAP MICROPHONE STATION 500 EAST BOULEVARD CHARLOTTE, NORTH CAROLINA 28203 704 | 332-7004 3665 JFK PARKWAY BUILDING 2, SUITE 103 FORT COLLINS, COLORADO 80525 970 | 232-3125 GFI 1/2" C. (STUBBED BEHIND DRYWALL) SYMBOL D PROVIDE GROUND CLAMP AND JUMPER IF CONDUIT-TO-CABLE TRAY CLAMP IS NOT UL LISTED FOR GROUNDING. CR 3/4" C. C PROVIDE CONDUIT-TO-CABLE TRAY CLAMP BY SAME MANUFACTURER AS TRAY. SIZE AS REQUIRED FOR CONDUIT M 18" (1'-6") UON NO TOP OF CABINET 48" (4'-0") UON NIGHT LIGHT 54" (4'-6") UON NL 64" (5'-4") UON AUTOMATIC TRANSFER SWITCH C S/S F FACP 72" (6'-0") UON ATS H/S MD TOP OF CABINET 78" (6'-6") UON NOT IN CONTRACT RI C S C TOP OF CABINET 80" (6'-8") OR 6" BELOW CEILING WHICHEVER IS LOWER NIC CONDUIT C F 84" (7'-0") UON AIR SAMPLING SMOKE DETECTION C TYPICAL 8'-0" CEILING BOTTOM OF DEVICE ASSD BELOW FINISHED GRADE C TOP MEC BFG C RI ~ ~ ABOVE COUNTER, MOUNT HORIZONTALLY TO CENTERLINE OF DEVICE,+6" ABOVE COUNTER OR BACK SPLASH MOTOR CIRCUIT PROTECTOR EXISTING CABLE TRAY TOP C S ~ ~ AC TYPICAL 9'-0" CEILING OR HIGHER ~ ~ ~ ~ MCP DESCRIPTION ~ ~ AMPERES A D SYMBOL DESCRIPTION ~ ~ SYMBOL NOTES: A NOTES: B SINGLE DOOR NO SCALE E101, E102, E103, EN103, E105, E106, E107, E110, E112 NOTES: C SINGLE DOOR NO SCALE E104A, E104B, EN104, EN105, E108A, E108B SINGLE DOOR DESCRIPTION 100% DD 95% CD 100% CD NIH FINAL RECORD DOCUMENTS B NO SCALE EN106 3/4" C. TO CABLE TRAY ATTIC LEVEL CEILING 1/2" C. (STUBBED BEHIND DRYWALL) WIRELESS ACCESS POINT, CEILING MOUNTED 1/2" CONDUIT (STUBBED BEHIND DRYWALL REFER TO NOTE 3) REQUEST TO EXIT DEVICE MOUNT CENTERED ON DOORS APPROXIMATLEY 12" ABOVE DOOR FRAME 3" FLUSH MOUNT DOOR CONTACT 3/4" C. CARD READER 4"X4" J-BOX W/SINGLE GANG MUD RING. REFER TO FLOOR PLAN FOR LOCATION 1/2" C. LOCKSET PROJECT NO: FWA 2284.12 CL ELECTRIC STRIKE (BY OTHERS) 48" AFF JAI APPROVED BY: CMK THESE DRAWINGS AND THE PROJECT MANUAL ARE INSTRUMENTS OF SERVICE AND REMAIN THE PROPERTY OF THE FWA GROUP ARCHITECTS. UNAUTHORIZED DUPLICATION OR REUSE WITHOUT WRITTEN CONSENT IS PROHIBITED. FLOOR LINE SECURE AREA NOTES: DRAWN BY: 1 . SECURITY JUNCTION BOX (SJB) SHALL BE 6X6x6 WITH SCREW COVER. SHEET TITLE 2 . ENCLOSURE AND CONDUIT TO BE PROVIDED BY ELECTRICAL CONTRACTOR. A A 3 . DOOR HEADER CONDUIT SHALL BE STUBBED TO JUST ENTER HEADER FRAME 3" TO 4" FROM OPENING SIDE OF DOOR. 4 . IF CONDUIT IS REQUIRED, INSTALL BY APPLICABLE CODE AND AUTHORITY HAVING JURISDICTION (AHJ). D SINGLE DOOR TECHNOLOGY LEGENDS AND DETAILS NO SCALE E201, E202 SHEET NUMBER 1 2 3 4 5 6 T-100