single door typical device mounting heights single door ab single

advertisement
1
2
3
4
5
6
ABBREVIATIONS LEGEND
(Not all symbols listed below are used on these drawings)
SEE MECHANICAL EQUIPMENT SCHEDULE
AFF
ABOVE FINISHED FLOOR
MIN
MINIMUM
AFG
ABOVE FINISHED GRADE
MLO
MAIN LUGS ONLY
ANN
ANNUNCIATOR
MTS
MANUAL TRANSFER SWITCH
ARF
ABOVE RAISED FLOOR
NC
NORMALLY CLOSED
B
F
C
B
F
NORMALLY OPEN
NTS
NOT TO SCALE
CABLE TELEVISION
OC
ON CENTER
CB
CIRCUIT BREAKER
OFCI
OWNER FURNISHED, CONTRACTOR INSTALLED
CCTV
CLOSED CIRCUIT TELEVISION
OFOI
OWNER FURNISHED, OWNER INSTALLED
(E)
EXISTING
OSWF
ON SITE WORK FORCE
EM
EMERGENCY
PB
PULL BOX
EMDC
EMERGENCY MAIN DISTRIBUTION CENTER
SB
STAND-BY
EP
EXPLOSION PROOF
SDC
SUB-DISTRIBUTION CENTER
EPO
EMERGENCY POWER OFF
TP
TAMPER PROOF
EVO
EMERGENCY VENTILATION ON/OFF
TVSS
TRANSIENT VOLTAGE SURGE SUPPRESSER
EWC
ELECTRIC WATER COOLER
TYP
TYPICAL
FA
FIRE ALARM
UF
UNDER FLOOR
G
GROUND
UG
UNDER GROUND
GCP
GENERATOR CONTROL PANEL
UON
UNLESS OTHERWISE NOTED
GFI
GROUND FAULT INTERRUPTING
UPS
UNINTERRUPTABLE POWER SUPPLY
HOA
HAND OFF AUTOMATIC
V
VOLTS
IG
ISOLATED GROUND
VFD
VARIABLE FREQUENCY DRIVE
MAX
MAXIMUM
W/
WITH
MCB
MAIN CIRCUIT BREAKER
W/O
WITHOUT
MCC
MOTOR CONTROL CENTER
WP
WEATHER PROOF
MDC
MAIN DISTRIBUTION CENTER
XFMR
TRANSFORMER
96" (8'-0") UON
CATV
MD
F
F
NOTE: ALL DEVICES INDICATED TO BE
INSTALLED AT DIFFERENT MOUNTING
HEIGHTS AND LOCATED WITHIN ONE STUD
SPACE FROM EACH OTHER SHALL ALIGN
VERTICALLY, ON THE SAME SIDE OF THE
STUD. WHERE WALL MOUNTED TELEPHONES
OCCUR OVER LIGHT SWITCHES, VOLUME
CONTROLS, ETC. OFFSET ONE STUD SPACE.
CONTROL PANELS
TC
T
ANN
W
1
IC
2
ZAM
S
D
CB
F
M
S
S
V
E
S
E
PB
P
P
PC
P
F
WP
F
BUSHING
CONDUIT
FINISHED FLOOR
CABLE TRAY
TYPICAL DEVICE MOUNTING HEIGHTS
GROUND LUG
NO SCALE
NOTES:
1.
HEIGHTS SHOWN ARE TYPICAL TO CENTERLINE OF BOX UNLESS NOTED OTHERWISE.
2.
WHERE EVER DEVICES ARE INDICATED TO BE ABOVE DOORS, DEVICE SHALL BE CENTERED BETWEEN TOP OF DOOR TRIM
AND CEILING LINE.
3.
MOUNTING HEIGHTS SHOWN ON ARCHITECTURAL ELEVATIONS SHALL GOVERN OVER THOSE SHOWN ABOVE.
NO SCALE
16143.1
~
~
~
~
~
~ ~
~
1
UH
E
EXISTING TO REMAIN
KITCHEN/OWNER/MEDICAL EQUIPMENT REFERENCE
R
EXISTING TO BE REMOVED
MECHANICAL EQUIPMENT REFERENCE
RL
EXISTING TO BE RELOCATED
ER
EXISTING TO REMAIN - REPLACE DEVICE
~
~
KEY NOTE REFERENCE
3"
~
~
CEILING
~
~
1
DESCRIPTION
REQUEST TO EXIT DEVICE
MOUNT CENTERED ON
DOORS APPROXIMATLEY 12"
ABOVE DOOR FRAME
MAGNETIC DOOR LOCK
(BY OTHERS)
1/2" C.
CARD READER 4"X4" J-BOX
W/SINGLE GANG MUD RING.
REFER TO FLOOR PLAN FOR
LOCATION
LOCKSET
TECHNOLOGY LEGEND
48" AFF
48" AFF
48" AFF
Imaging Suite Fit-out &
Underground Power
Feed
FLUSH MOUNT DOOR CONTACT
1/2" C.
FLUSH MOUNT DOOR CONTACT
ELECTRIC
STRIKE
(BY OTHERS)
3"
3/4" C.
CARD READER 4"X4" J-BOX
W/SINGLE GANG MUD RING.
REFER TO FLOOR PLAN FOR
LOCATION
CL
CL
C
1/2" CONDUIT (STUBBED BEHIND
DRYWALL REFER TO NOTE 3)
REQUEST TO EXIT DEVICE
MOUNT CENTERED ON
DOORS APPROXIMATLEY 12"
ABOVE DOOR FRAME
3"
1/2" C.
CL
1/2" C.
(STUBBED BEHIND DRYWALL)
1/2" C.
FLUSH MOUNT DOOR CONTACT
LOCKSET
CEILING
1/2" C.
(STUBBED BEHIND DRYWALL)
3/4" C.
CARD READER 4"X4" J-BOX
W/SINGLE GANG MUD RING.
REFER TO FLOOR PLAN FOR
LOCATION
LOCATE BOX IN ATTIC ABOVE ROOMS
E201 OR E202, WHICHEVER IS CLOSER
LOCATE BOXES IN ATTIC ABOVE ROOMS
E201 OR E202, WHICHEVER IS CLOSER
1/2" CONDUIT (STUBBED BEHIND
DRYWALL REFER TO NOTE 3)
3/4" C.
TO CABLE TRAY
ATTIC LEVEL
120 VAC MAGLOCK POWER
SUPPLY (BY OTHERS)
LOCATE BOX IN ATTIC ABOVE ROOMS
E201 OR E202, WHICHEVER IS CLOSER
1/2" CONDUIT (STUBBED BEHIND
DRYWALL REFER TO NOTE 3)
REQUEST TO EXIT DEVICE
MOUNT CENTERED ON
DOORS APPROXIMATLEY 12"
ABOVE DOOR FRAME
16111.1
3/4" C.
TO CABLE TRAY
ATTIC LEVEL
CEILING
12-23-98
3/4" C.
TO CABLE TRAY
ATTIC LEVEL
(Not all symbols listed below are used on these drawings)
SYMBOL
CONDUIT-TO-CABLE TRAY
CONDUIT CONNECTION
3-27-07
REFERENCE SYMBOLS LEGEND
DESCRIPTION
PANIC
HARDWARE
CSU PROJECT #09-059
CL
COLORADO STATE UNIVERSITY
FOOTHILLS CAMPUS
FORT COLLINS, CO
ELECTRIC
STRIKE
(BY OTHERS)
EMERGENCY
DOOR RELEASE
48" AFF
DATE
MARK (YYYY-MM-DD)
2011-01-07
2011-03-04
2011-05-11
2011-10-28
(Not all symbols listed below are used on these drawings)
SYMBOL
DESCRIPTION
TELEPHONE TERMINAL CABINET
#
DESCRIPTION
KEYPAD
1 . SECURITY JUNCTION BOX (SJB) SHALL BE 6X6x6 WITH SCREW COVER.
1 . SECURITY JUNCTION BOX (SJB) SHALL BE 6X6x6 WITH SCREW COVER.
1 . SECURITY JUNCTION BOX (SJB) SHALL BE 6X6x6 WITH SCREW COVER.
DOOR CONTACT
2 . ENCLOSURE AND CONDUIT TO BE PROVIDED BY ELECTRICAL CONTRACTOR.
2 . ENCLOSURE AND CONDUIT TO BE PROVIDED BY ELECTRICAL CONTRACTOR.
2 . ENCLOSURE AND CONDUIT TO BE PROVIDED BY ELECTRICAL CONTRACTOR.
3 . DOOR HEADER CONDUIT SHALL BE STUBBED TO JUST ENTER HEADER FRAME 3" TO 4" FROM
OPENING SIDE OF DOOR.
3 . DOOR HEADER CONDUIT SHALL BE STUBBED TO JUST ENTER HEADER FRAME 3" TO 4" FROM
OPENING SIDE OF DOOR.
3 . DOOR HEADER CONDUIT SHALL BE STUBBED TO JUST ENTER HEADER FRAME 3" TO 4" FROM
OPENING SIDE OF DOOR.
4 . IF CONDUIT IS REQUIRED, INSTALL BY APPLICABLE CODE AND AUTHORITY HAVING JURISDICTION
(AHJ).
4 . IF CONDUIT IS REQUIRED, INSTALL BY APPLICABLE CODE AND AUTHORITY HAVING JURISDICTION
(AHJ).
4 . IF CONDUIT IS REQUIRED, INSTALL BY APPLICABLE CODE AND AUTHORITY HAVING JURISDICTION
(AHJ).
ELECTRIC DOOR STRIKE
TELEVISION OUTLET
EH
ELECTRIC HINGE
CLOCK OUTLET (D = DOUBLE SIDED)
EP
ELECTRIC POWER TRANSFER
EMERGENCY EXIT BUTTON
RX
REQUEST TO EXIT
S
PAGING SYSTEM SPEAKER
PS
POWER SUPPLY
S
PAGING SYSTEM HORN (HIGH OUTPUT)
ML
MAGNETIC DOOR LOCK
S
PAGING SYSTEM SPEAKER, SURFACE MOUNT
GB
GLASS BREAK DETECTOR (WALL MOUNTED)
SECURITY CAMERA, (1) CAT5E, DEVICE BY OWNER
GB
GLASS BREAK DETECTOR (CEILING MOUNTED)
PROJECTOR
MD
MOTION DETECTOR (WALL MOUNTED)
IC
INTERCOM STATION
MD
MOTION DETECTOR (CEILING MOUNTED)
VC
VOLUME CONTROL
DA
DURESS ALARM
PROJ
M
SECURE AREA
KP
ES
D
SECURE AREA
TELEPHONE OR DATA OUTLET (# = NUMBER OF CAT6 CABLES)
TELEPHONE/POWER POLE
C
SECURE AREA
CARD READER
EL
TP
FLOOR LINE
CR
ELECTRIC DOOR LOCK
W
FLOOR LINE
SECURITY CONTROL PANEL
TELEPHONE, WALL MOUNT (# = NUMBER OF CAT6 CABLES)
#
FLOOR LINE
TELEPHONE TERMINAL BACKBOARD
TELEPHONE OR DATA OUTLET, FLOOR MOUNTED (# = NUMBER OF CAT6 CABLES)
#
B
SYMBOL
SEC
WAP
MICROPHONE STATION
500 EAST BOULEVARD
CHARLOTTE, NORTH CAROLINA 28203
704 | 332-7004
3665 JFK PARKWAY BUILDING 2, SUITE 103
FORT COLLINS, COLORADO 80525
970 | 232-3125
GFI
1/2" C.
(STUBBED BEHIND DRYWALL)
SYMBOL
D
PROVIDE GROUND CLAMP AND JUMPER IF
CONDUIT-TO-CABLE TRAY CLAMP IS NOT
UL LISTED FOR GROUNDING.
CR
3/4" C.
C
PROVIDE CONDUIT-TO-CABLE TRAY CLAMP BY SAME
MANUFACTURER AS TRAY. SIZE AS REQUIRED FOR
CONDUIT
M
18" (1'-6") UON
NO
TOP OF CABINET
48" (4'-0") UON
NIGHT LIGHT
54" (4'-6") UON
NL
64" (5'-4") UON
AUTOMATIC TRANSFER SWITCH
C
S/S
F
FACP
72" (6'-0") UON
ATS
H/S
MD
TOP OF CABINET
78" (6'-6") UON
NOT IN CONTRACT
RI
C S
C
TOP OF CABINET
80" (6'-8") OR 6" BELOW CEILING WHICHEVER IS LOWER
NIC
CONDUIT
C
F
84" (7'-0") UON
AIR SAMPLING SMOKE DETECTION
C
TYPICAL 8'-0" CEILING
BOTTOM OF DEVICE
ASSD
BELOW FINISHED GRADE
C
TOP
MEC
BFG
C
RI
~
~
ABOVE COUNTER, MOUNT HORIZONTALLY TO CENTERLINE
OF DEVICE,+6" ABOVE COUNTER OR BACK SPLASH
MOTOR CIRCUIT PROTECTOR
EXISTING CABLE TRAY
TOP
C S
~
~
AC
TYPICAL 9'-0" CEILING OR HIGHER
~ ~
~
~
MCP
DESCRIPTION
~
~
AMPERES
A
D
SYMBOL
DESCRIPTION
~
~
SYMBOL
NOTES:
A
NOTES:
B
SINGLE DOOR
NO SCALE
E101, E102, E103, EN103, E105, E106, E107, E110, E112
NOTES:
C
SINGLE DOOR
NO SCALE
E104A, E104B, EN104, EN105, E108A, E108B
SINGLE DOOR
DESCRIPTION
100% DD
95% CD
100% CD
NIH FINAL RECORD
DOCUMENTS
B
NO SCALE
EN106
3/4" C.
TO CABLE TRAY
ATTIC LEVEL
CEILING
1/2" C.
(STUBBED BEHIND DRYWALL)
WIRELESS ACCESS POINT, CEILING MOUNTED
1/2" CONDUIT (STUBBED BEHIND
DRYWALL REFER TO NOTE 3)
REQUEST TO EXIT DEVICE
MOUNT CENTERED ON
DOORS APPROXIMATLEY 12"
ABOVE DOOR FRAME
3"
FLUSH MOUNT DOOR CONTACT
3/4" C.
CARD READER 4"X4" J-BOX
W/SINGLE GANG MUD RING.
REFER TO FLOOR PLAN FOR
LOCATION
1/2" C.
LOCKSET
PROJECT NO:
FWA 2284.12
CL
ELECTRIC
STRIKE
(BY OTHERS)
48" AFF
JAI
APPROVED BY:
CMK
THESE DRAWINGS AND THE PROJECT
MANUAL ARE INSTRUMENTS OF SERVICE AND
REMAIN THE PROPERTY OF THE FWA GROUP
ARCHITECTS. UNAUTHORIZED DUPLICATION
OR REUSE WITHOUT WRITTEN CONSENT IS
PROHIBITED.
FLOOR LINE
SECURE AREA
NOTES:
DRAWN BY:
1 . SECURITY JUNCTION BOX (SJB) SHALL BE 6X6x6 WITH SCREW COVER.
SHEET TITLE
2 . ENCLOSURE AND CONDUIT TO BE PROVIDED BY ELECTRICAL CONTRACTOR.
A
A
3 . DOOR HEADER CONDUIT SHALL BE STUBBED TO JUST ENTER HEADER FRAME 3" TO 4" FROM
OPENING SIDE OF DOOR.
4 . IF CONDUIT IS REQUIRED, INSTALL BY APPLICABLE CODE AND AUTHORITY HAVING JURISDICTION
(AHJ).
D
SINGLE DOOR
TECHNOLOGY
LEGENDS AND
DETAILS
NO SCALE
E201, E202
SHEET NUMBER
1
2
3
4
5
6
T-100