CARRIAGE HOUSE 30 TO 260 CONVERTER AND VISITOR ROOM SIGNAL SELECTOR (RACK 5) 30 MHZ RCP FROM CARRIAGE HOUSE VIA CABLE COMPENSATION AMPLIFIER IN RACK 7 TWO 3OMHZ SIGNALS TO VISITOR EQUIPMENT ROOM RCP (OR POL A) 11 FP FP LCP (OR POL A OR POL B) -20dB -20dB 30MHZ -3 100 MHz LOW PASS 255-265MHZ BANDPASS 3dB 3dB LO RCP 30 MHZ LCP FROM CARRIAGE HOUSE VIA CABLE COMPENSATION AMPLIFIER IN RACK 7 5-12 TWO CARRIAGE HOUSE SIGNALS, UPCONVERTED TO 260 MHZ 11 FP FP -3 30MHZ 100 MHz LOW PASS L0 2 +13dBm CHANNEL 2 6dB 30 MHz to 260 MHz UPCONVERTER RACK 6 UNIT 19 290-MHz LO Inp 5-13 30-MHz Signal Inp Front BANDPASS FILTER 30 MHZ CENTER FREQ 12 MHZ BANDWIDTH "OUT 2" (REAR PANEL) 19 "OUTPUT 2" (FRONT PANEL) 3dB -3 BANDPASS FILTER 30 MHZ CENTER FREQ 12 MHZ BANDWIDTH BLANK BANDPASS FILTER 30 MHZ CENTER FREQ 40 MHZ BANDWIDTH Rear NORMAL Rear -3 19 "OUT 1" (REAR PANEL) 19 "OUT PUT 1" (FRONT PANEL) -3 11 3dB I LO INPUT FOR CHANNELS 1 & 4 FROM p2 (SYNTH. 4, PORT 1 FROM LO DISTRIBUITION CHASSIS, RACK 5 UNIT 7) BPF 260 MHz CF 30 MHz BW R 3dB L0 4 +13dBm CHANNEL 4 BANDPASS FILTER 30 MHZ CENTER FREQ 12 MHZ BANDWIDTH 3dB 19 "OUT 4" (REAR PANEL) 19 "OUTPUT 4" (FRONT PANEL) 19 "OUT 3" (REAR PANEL) 19 "OUTPUT 3" (FRONT PANEL) -3 F "SINGLE INPUT" NOTE: CH A & CH B delays are matched in "Thru" mode. Thru BANDPASS FILTER 30 MHZ CENTER FREQ 40 MHZ BANDWIDTH NORMAL SW is currently controlled manually from front panel, but will eventually be under remote control. 3dB LO INPUT FOR CHANNEL 3 FROM p2 (SYNTH. 3, PORT 1 FROM LO DISTRIBUITION CHASSIS, RACK 5 UNIT 7) See 'WB_30-260MHz)conv.fc7' & 'Coil_driver.fc7' 12 3dB -3 BLANK Convert Rear Rear SELECT 30 MHZ SOURCE FOR VISITOR ROOM CARRIAGE HOUSE ch OR GREGORIAN grn (grw=grn) EXAMPLE: if2 "if2_vis30mhz grn" -3 L SIGNAL INPUT FOR CHANNELS 3 & 4 FROM CHANNEL B, AMP 2, PORT 2 (page 2) THIS IS HOW CH SIGNALS GET INTO THE "NORMAL" IF PATH, VIA SELECTION IN 5-4. Front CHANNEL 1 6-19 LCP 3dB LO LCP 19 -3 3dB SIGNAL INPUT FOR CHANNELS 1 & 2 FROM CHANNEL A, AMP 2, PORT 2 (page 1) TO TRANSFER SWITCH (p. 1) IN RACK 5-4. 255-265MHZ BANDPASS 3dB LO INPUT FOR CHANNEL 2 FROM p2 (SYNTH. 2, PORT 1 FROM LO DISTRIBUITION CHASSIS, RACK 5 UNIT 7) RCP -20dB -20dB 260 MHZ TO 30 MHZ DOWN CONVERTER RACK 5 UNIT 13 CHANNEL 3 T ("DUAL INPUT") BANDPASS FILTER 30 MHZ CENTER FREQ 12 MHZ BANDWIDTH -3 CAL COMMAND SELECTOR EXAMPLE: if2 "if2_calsrc 8" 3-BIT CONTROL FROM HPIB CHASSIS L0 3 +13dBm 3dB 4 6dB "BLANKING ENABLED" "BLANKING ACTIVE" 3 2 1 "LOGIC PROBE" 50 NC REAR PANEL BNC INPUTS NC FROM INTERIM CORRELATOR 25 HZ SQ. WAVE FROM CLOCK DIST. 3 9 3 ENABLE BLANKING INPUT EXAMPLE: if2 "if2_430blnk T" (USED FOR 430 MHZ RADAR) PAGE 3 OF 3: 260 MHZ TO 30 MHZ CONVERTER, CARRIAGE HOUSE 260 TO 30 CONVERTER 30 MHz to 260 MHz UPCONVERTER AND VISITOR ROOM SIGNAL SOURCE SELECTOR, CAL ENABLE SELECTOR 2 CAL ON/OFF CONTROL SOURCE-SELECTOR - RACK 5 UNIT 11 TTL HI = BLANKING ON TTL LO = BLANKING OFF NO CONNECTION = BLANKING OFF 8:1 MUX 3 4 10 SOURCE #7 FRONT PANEL BNC "1" "0" CAL ON/OFF CONTROL SIGNAL TO DOME 5 6 7 SELECT 2 BANDS FROM POL. A & 2 BANDS FROM POL. B ("TRUE") OR 4 BANDS FROM POL. A ("FALSE") EXAMPLE: if2 "if2_2a2b30 T" SOURCE #8 FRONT PANEL TOGGLE SW. 8 LED "1" "0" file: ifloblok jbh 1-29-01 REV APR. 7, 2005 IFDWN3(rev).fc7 DEW 11 Feb 2009 (added switchable upconverter in 6-19) IFDWN3(rev_2).fc7 DEW 28 Aug 2012 (corrected paths into & out of 5-12) FRONT PANEL LEDS INDICATE SELECTED INPUT PORT 1 BLANKING INPUT DOWNSTAIRS IF-LO SYSTEM FUNCTIONAL BLOCK DIAGRAM 3 LINE TO 8 LINE DECODER 5-11 BNC MONITOR PORT (SELECTS THE ON/OFF CONTROL SOURCE FOR A SINGLE CAL ON/OFF SIGNAL THAT GOES TO THE DOME. IN THE DOME, A DISTRIBUTOR ROUTES THE SIGNAL TO THE CAL DIODE(S) OF A SELECTED RECEIVER)