D185 Installation Instructions EN Reverse Polarity Signaling Module D185 | Installation Instructions | 1.0 Description 1.0 Description Use the Underwriters Laboratories, Inc. (UL) Listed D185 Reverse Polarity Signaling Module (Figure 1) with Bosch Security Systems, Inc. (Bosch) control panels. You can also use the D185 with non-Bosch compatible UL Listed control panels where referenced in the associated installation instructions. Figure 1: D185 Module 1 2 3 2.0 Alarm, Trouble, and Supervisory Conditions If a single pair of telco lines connects to the D185, it signals alarm and trouble conditions to the monitoring station. If two pairs connect to the D185, it also signals supervisory conditions to the monitoring station. 3.0 Alarm and Trouble Responses (One Pair of Telco Lines) The D185 provides a constant 10 mA of current to the alarm telco outputs and 14 mA of current to the supervisory output. This module responds to an alarm (fire) input from the control panel by reversing the alarm telco output polarity. The D185 responds to a trouble input from the control panel by interrupting the current to the alarm telco outputs. GND PWR 8 12345678- PWR TRBL SUPV ALRM TRIG TRIG TRIG 7 SUPV SUPV ALRM ALRM GND SUPV ZONE 6 5 4 Alarm Test Switch Alarm Test LED Supervisory signal adjuster Alarm signal adjuster Supervision Zone terminal Telco terminals Inputs from control panel 12 VDC or 24 VDC auxiliary power inputs Follow these instructions when installing the D185. This module connects a control panel with either a single set or a pair of leased telephone company (telco) lines in NFPA 72 remote station applications. Local regulations might prohibit the transmission of trouble signals on the alarm circuit. The trouble feature is not suitable for remote station protected premises service where the local authority having jurisdiction (AHJ) requires separate transmission circuits for alarm, supervisory, and trouble signals. System configuration is subject to the local AHJ’s approval. If the control panel sends an alarm during a trouble signal, the D185 overrides the trouble telco output and responds with an alarm telco output (reversed polarity). The D185 transmits system alarm status information from the control panel to a monitoring station. This module operates with either a 12 VDC or 24 VDC supply. All circuits are power limited. The three D185 input terminals accept alarm, trouble, or supervisory input from the control panel. It responds to the input by communicating these conditions to a monitoring station. There is a builtin 20 sec (±5 sec) delay of alarm output. Under normal conditions, the D185 sends a steady current to a monitoring station. In an alarm or supervisory condition, the D185 reverses the output current polarity and signals a trouble condition by interrupting the output voltage and current. 2 Bosch Security Systems, Inc. | 10/08 | F01U034781-02 D185 | Installation Instructions | 4.0 Supervisory Response (Two Pairs of Telco Lines) . 4.0 Supervisory Response (Two Pairs of Telco Lines) If the supervisory telco outputs connect to a monitoring station, the D185 responds to a supervisory signal by reversing the polarity of the supervisory telco outputs. 6.1 Removing Power from the FACP Inform the operator and the local AHJ before installing this module in an existing system. Disconnect all power to the control panel before installing this module. 1. Before making or removing any connections to the FACP, remove the standby battery power. 2. Remove AC power from the system at the dedicated 120 VAC breaker. 6.2 Table 1: D185 Responses Trigger Response Alarm Trouble Supervisory Alarm outputs polarity reversed Alarm outputs current interrupted* Supervisory outputs (if any) polarity reversed * Alarm overrides 5.0 Alarm Test The Alarm Test Switch (Item 1 in Figure 1 on page 2) disables module output during testing that triggers a trouble output from the D185 during testing. Generally, this switch is off but during an Alarm Test, you must move the switch to the ON position. Turning on the Alarm Test Switch lights the Alarm Test LED (Item 2 in Figure 1). Mounting the D185 The D185 mounts on a snap-track and installs in the control panel enclosure. You can also mount the D185 in a separate, adjacent enclosure connected to the control panel by conduit or other protection against wiring damage. The snap-track is slotted and drilled for quick installation. 6.3 Connecting the D185 The D185 has 12 screw terminal connection points, 6 on the left side for input points and 6 on the right side for output points (Figure 2). Figure 2: D185 Terminal Block 1 SUPV SUPV ALRM GND ALRM SUPV ZONE 6.0 Installation Standards Install, test, and maintain the D185 according to these instructions, NFPA 72, local codes, and the AHJ. Failure to follow these instructions can result in failure of the D185 to report an alarm condition. Bosch is not responsible for improperly installed, tested, or maintained devices. Install the D185 up to 20 ft (6 m) from the control panel with a minimum of 22 AWG (0.8 mm) wire. Ensure all wiring is in conduit. Install the D185 in a system by: • Removing power from the control panel, • Mounting the D185, • Connecting the D185, • Restoring power to the control panel, and • Adjusting the amount of output current. Bosch Security Systems, Inc. | 10/08 | F01U034781-02 GND PWR PWR TRBL TRIG SUPV TRIG ALRM SUPV SUPV ALRM ALRM GND TRIG SUPV ZONE 2 GND PWR PWR 1 - Output points TRBL SUPV ALRM TRIG TRIG TRIG 2 - Input points Use Table 2 to connect the D185 and control panel. Connect the SUPV ZONE Terminal to the input of a standard point or zone on the control panel. When the Alarm Test Switch activates, the SUPV ZONE Terminal changes from an open collector (high resistance) to sinking current (ground). 3 D185 | Installation Instructions | 6.0 Table 2: Installation Standards D185 to Control Panel Connection Sequence D185 Terminal Control Panel Terminal No. Name 1 GND to Name Earth ground 2 PWR - to Common 3 PWR + to Vaux + or SMK + (12 VDC or 24 VDC) 4 TRBL TRIG to Trouble output or OctoRelay 5 SUPV TRIG to Supervisory output or OctoRelay 6 ALRM TRIG to Alarm output or OctoRelay 7 SUPV + to Telco line 8 SUPV - to Telco line 9 ALRM - to Telco line 10 ALRM + to Telco line 11 GND to Not used 12 SUPV ZONE to Zone input To adjust the amount of output current required on the telco output, use a screwdriver to rotate the alarm signal adjuster (Item 4 in Figure 1 on page 2). 6.4 Wiring the D185 to a D7024 or DS9400 Series Control Panel with ROM Version 2.03A and Newer The D185 can signal alarm, trouble, and supervisory conditions. Figure 3 shows the D185 used to signal alarm and trouble conditions only. Supervisory conditions can also be signaled using a third relay and an additional leased line. In the example shown in Figure 3, you must program Relay 1 to operate on alarm and Relay 2 to operate on trouble. Program Input 4 as a supervisory input point. Any alarm causes an interruption in the voltage to the monitoring station. Placing the D185 in Test Mode causes a supervisory trouble condition. Connect input power only to the PWR Terminals. 4 Bosch Security Systems, Inc. | 10/08 | F01U034781-02 D185 | Installation Instructions | 6.0 Installation Standards . Figure 3: Wiring the D185 to a D7024 or DS9400 Series Control Panel 1 2 GND PWR - 1 NC2 31 COM2 30 2 PWR TRBL + TRIG 3 4 SUPV ALRM SUPV SUPV ALRM ALRM GND TRIG TRIG + + 5 6 7 8 9 10 11 SUPV ZONE 12 3 13 COM1 27 NO1 26 SMK+ 25 SMK- 24 4 5 12 21 6 7 1234567- 11 4- 20 L+ 19 3- 18 10 9 8 D185 Module Fire panel Relay 2 Relay 1 Smoke power Earth ground Input points Bosch Security Systems, Inc. | 10/08 | F01U034781-02 9 8910 11 12 13 - 2.21 kΩ end-of-line (EOL) for supervisory input Blue wire Yellow wire D275 EOL Supervisory Relay Black wire To monitoring station 5 D185 | Installation Instructions | 6.0 6.5 Installation Standards Wiring the D185 to an FPD-7024 Control Panel Figure 4 shows the D185 used to signal alarm and trouble conditions when wired to an FPD-7024. Figure 4: Wiring the D185 to an FPD-7024 Control Panel 1 GND PWR - 1 PWR TRBL SUPV ALRM SUPV SUPV ALRM ALRM GND SUPV + TRIG TRIG TRIG + + ZONE 2 3 4 5 6 7 8 9 10 11 12 NC2 2 COM2 13 12 COM1 3 NO1 4 SMK+ 11 SMK- 5 10 8 6 9 4A+ 7 4B+ 4B- 9 4A- 1234567- 6 D185 Module Relay 2 Relay 1 Smoke power Earth ground Fire panel Input points 8910 11 12 13 - 2.2 kΩ EOL Blue wire Yellow wire D275 EOL Supervisory Relay Black wire To monitoring station Bosch Security Systems, Inc. | 10/08 | F01U034781-02 D185 | Installation Instructions | 6.0 Installation Standards . 6.6 Wiring the D185 to a D9412GV2, D7412GV2, D9412G, or D7412G Control Panel Figure 5 shows the D185 used to signal alarm and trouble conditions when wired to a D9412GV2, D7412GV2, D9412G, or D7412G Control Panel. Supervisory conditions can also be signaled using a third relay and an additional leased line. Figure 5: GND PWR - 1 2 Wiring the D185 to a D9412GV2, D7412GV2, D9412G, or D7412G Control Panel PWR TRBL SUPV ALRM SUPV SUPV ALRM ALRM GND SUPV + TRIG TRIG TRIG + + ZONE 3 4 5 6 7 8 9 4 6 10 11 1 12 3 2 5 43489F 7 LEDs Off When Normal YEL Charging Status RED Low Battery - 12.1 VDC Digital Alarm Communicator Transmitter 6 1 2 + AUX POWER 4 BATTERY NEGATIVE ONLY 7 CAUTION: See Manual For Power Requirements Relating to Terminals RELAY A 7 RELAY B 8 RELAY C 9 COMMON 10 6 7 POWER + This equipment should be installed in accordance with the NFPA 70 (National Electrical Code) and NFPA 72 (National Fire Alarm Code) for Local, Central Station, Remote Station and Household Fire Warning Systems and under the limits of the Local Authority Having Jurisdiction (National Fire Protection Association, Batterymarch Park, Quincy, MA 02269) Printed information describing proper installation, operation, testing, maintenance, evacuation planning and repair service is to be provided with this equipment. DATA BUS A 31 GREEN DATA BUS B 30 COMMON 29 ZONEX OUT 1 28 N.F.P.A. Style 3.5 Signaling Line Circuits ZONEX IN 1 27 ZONEX OUT 2 26 ZONEX IN 2 25 ZONEX POWER + 24 D9412G Control / Communicator is UL Listed For Central Station, Local, Remote Station and Household Fire Alarm, and Central Station, Local, Police Station Connect and Household Burglar Alarm. System is Intended To Be Checked By A Qualified Technician At Least Every 3 Years. The types of initiating circuits that the panel has been approved for are A, M, W, SS. Open Normal Short EARTH GROUND GROUND FAULT DETECT Enabled Disabled Point 1 Point 2 Point 3 Point 4 Point 5 Point 6 VOLTAGE RANGES 3.7 - 5.0 VDC 2.0 - 3.0 VDC 0.0 - 1.3 VDC Point 7 Point 8 PHONE MONITOR SELECT LOOP START GND START GROUND START PHONE RED Requires LED Relay # D136 in ON WHEN Ground COMMUNICATING OFF WHEN IDLE Start Socket 11 12 13 14 15 16 17 18 19 20 21 22 32 YELLOW BLACK Multi-Battery Installation Requires Battery: Replace Every 3 to Model No. D122 Dual Battery Harness. 5 years with Model D126, 12 V Improper Installation Can Be a Fire Hazard. 7 Amp Hr Lead Acid Battery PROGRAMMABLE ALARM OUTPUTS Terminals 7 & 8 Requires Optional D136 Relay In ALT ALARM & SW AUX RED WARNING! Maximum Charging Current 1.4 Amps. BATTERY POSITIVE ONLY 6 PERIPHERAL DEVICE CONNECTIONS POWER SUPPLY REQUIREMENTS The Power Supply Provides a Maximum of 1.4 Amps For The Control Panel and All Accessory Devices. For System Loading, See OperationInstallation Manual #43488 ___. All External Connections Except Terminal 5 (Battery Positive) Are Inherently Power Limited. Requirements For Battery Standby Time May Reduce Allowable Output. CLASS 2 TRANSFORMER 16.5 VAC 40 VA 60 Hz Part No. D1640 Internally Fused - Do Not short Requires Unswitched Outlet Do Not Share With Other Equipment 3 5 Reset Pin Disable All Except Battery Charging And Programming Reference Manual #43494 ___ For System Wiring Diagram, Issue A Reference Document #33284 ___ For Compatible Smoke Detectors 10.2 VDC - Battery Load Shed Point 8 GND FAULT Detect D E I N S A A B B L L E E ZONEX COMMON 23 PROG CONN GRN 8 7 7 9 1 - D185 Module 2 - D9412GV2, D7412GV2, D9412G, or D7412G Control Panel 3 - Black wire 4 - To monitoring station 56789- D275 EOL Supervisory Relay Red wire Blue wire ALT ALARM socket (enables Terminal 7 output)* P105F EOL Resistor (P/N: 15-03130-004) * For the D9412G and D7412G, insert the D136 with the three pins positioned toward the top of the control panel. This is not required on the D9412GV2 and D7412GV2 as the relays are included. A D136 Relay Module (located under the control panel) is required when using Relay B on the D9412G and D7412G. Refer to the D9412G/D7412G Operation & Installation Guide (P/N: 43488) for installation instructions. The D9412GV2 and D7412GV2 have built-in D136 Relays. Bosch Security Systems, Inc. | 10/08 | F01U034781-02 7 D185 | Installation Instructions | 7.0 Specifications Figure 5 on page 7 shows Relay A programmed to activate for fire alarms (program as steady output) and Relay B programmed to activate for summary fire trouble. Point 1 is programmed for supervisory. Any alarm causes an interruption to the monitoring station. Placing the D185 in Test Mode causes a Supervisory Trouble condition. Refer to the panel wide relays in the D9412GV2/D7412GV2 Program Entry Guide (P/N: F01U003636) and the D9412G/D7412G Program Entry Guide (P/N: 47775). You can also refer to these program entry guides for complete programming instructions. 7.0 Specifications Table 3: Specifications Power Inputs (for standby battery calculations) 12 V Start up voltage Minimum voltage Maximum voltage Idle current draw Alarm current draw Supervisory Trouble Supervisory Zone (current sink) Telco Output Current Adjustment Range Temperature Humidity Environment Wiring Input Supv. No Current No Current Active High Active High No Current Active High Active High Trouble No Current Active High No Current Active High No Current No Current Active High Alarm Normal Output Supv. Normal No Current No Current No Current Reversed Polarity Reversed Polarity Reversed Polarity Normal Reversed Polarity Reversed Polarity Normal Reversed Polarity Reversed Polarity 10.2 VDC 30 VDC 120 mA 300 mA 143 mA Minimum Maximum Voltage 10.2 VDC 30 VDC Current 2.25 mA 8.1 mA Voltage 10.2 VDC 30 VDC Current 2.25 mA 8.1 mA Voltage 10.2 VDC 30 VDC Current 2.25 mA Minimum 8.1 mA Maximum 0 mA 35 mA Minimum Maximum 2.5 mA 15 mA Current Alarm No Current No Current No Current No Current Active High Active High Active High Input and Output States 11 VDC 245 mA Inputs Alarm* 24 V Table 4: Nominal 10 mA +5 mA +32°F to +120°F (0°C to +49°C) 93% Indoor/dry 22 AWG to 12 AWG (0.8 mm to 2.3 mm) * The alarm activation delay is 20 sec ±5 sec. 8 Bosch Security Systems, Inc. | 10/08 | F01U034781-02 D185 | Installation Instructions | Notes . Notes Bosch Security Systems, Inc. | 10/08 | F01U034781-02 9 Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY 14450-9199 (800) 289-0096 © 2008 Bosch Security Systems, Inc. F01U034781-02