Mounting and Connecting Wiring Schematics

advertisement
Mounting and Connecting
1.
Locate the components required
for mounting the pattern controller.
2.
Mounting slot
Loosen the socket head mounting
screw. Retain screw for re-installation.
Ship-with Kit
277894
(Qty: 1)
Back panel
Slide the mounting plate out from
the mounting slot.
Mount the mounting plate on a rigid
support (e.g. wall or post) to prevent
external vibration. Secure with screws
provided in the ship-with kit.
2.95 in.
(75 mm)
3.
5.
1123338
(Qty: 3)
982594
M4 x 10 mm
(Qty: 4)
3.93 in.
(100 mm)
4.
Mounting plate
983116
M4 Lock Washer
(Qty: 4)
Installation Guide, 1123405_01
1122386
Fuse, 32V,
7.5 A,
(Qty: 2)
114876
Fuse, 250V,
4 A,
(Qty: 2)
1122831
16-Positions,
JP2
(Qty: 1)
1122832
14-Positions,
JP3
(Qty: 1)
1122833
1122901
Spectra™ 30
12-Positions,
Control System
JP4
Quick Reference Guide
(Qty: 1)
1122837
7-Positions,
JP17
(Qty: 1)
1122834
8-Positions,
JP5
(Qty: 1)
1123358
2-Positions,
JP16
(Qty: 1)
1123405
Spectra™ 30
Control System
Installation Guide
1123406
Spectra™ 30
1123841
Spectra™ 30
Control System
Safety Instructions
Control System
ProductManual
CD contains Product Manuals
emanuals.nordson.com/
adhesives
Dimensions
Slide pattern controller into the
mounting plate. Secure with
socket head mounting screw
removed in step 2.
9.76 in. (248 mm)
2.95 in.
(75 mm)
6.
Open the pattern controller cover by
loosening the four M5 captive
screws.
7.
9.84 in.(250 mm)
3.93 in.
(100 mm)
8.
Re-install the cover. Press switch to
turn on the pattern controller.
Route all the cables through the
conduits located on the base panel.
Refer to the Wiring Schematics for
connection details.
5.66 in.
(144 mm)
NORDSON CORPORATION SDULUTH, GA SUSA Swww.nordson.com
Wiring Schematics
Refer to the Connector Table and the Internal Board drawings to make internal connections.
Warning:
Allow only personnel with appropriate training and
experience to operate or service the equipment.
The use of untrained or inexperienced personnel to
operate or service the equipment can result in injury, including death, to themselves and others, and
damage to the equipment.
Conduit
System
Input/Output
(4 In, 2 Out)*
Ref
JP3/4
JP2
Encoder (1)
JP4
Run-up Out (1)/
Machine Stop
Outputs
JP17
AC Input
Equipment must be properly grounded and fused according to its rated current consumption (see ID plate). Failure to follow the safety
procedures can result in serious injury.
Connecting
Location
Trigger (1-4)
Applicator Outputs
(4)
Warning:
JP5
JP16
PE (Ground)
Install cooling fan if needed
(optional)
*Install PG connectors from
ship-with kit as needed
L1L2L2 /N
PE/G
IMPORTANT:
To Insert Wires in Terminal Blocks:
Use 10 mm strip length
Insert wire into spring-cage
clamp in either position
To Remove Wires from Terminal Blocks:
Press the release button
slot with a small
screwdriver and pull the
wire to remove
Wire Gauge Range:
JP5 and JP17 - 5 mm pitch connectors
(applicator and run-up): 14 – 24 AWG
JP 2, JP3, JP4 and JP7 - 3.5 mm pitch
connectors (triggers, encoders, and system I/O):
16 – 24 AWG
JP16 - AC Input Plug: 12 – 24 AWG
Using Setup Wizard at First Time Startup
Using touch gestures in this guide:
3.
Hold
Tap
1.
E NCODER
Set up the encoder.
a. Tap button to
select no encoder.
4.
S CALE
AND
U NITS
Scaling options allow you to program
patterns in time (ms) or distance (mm or in.).
L ANGUAGE
Scroll to select your language.
b. Tap buttons to select
a single phase encoder.
Encoder Icon Status:

c. Tap buttons to select
a quadrature encoder.
NOTE: When using an optional encoder, scaling
encoder not detected.

!
2.
encoder detected and license
available to enable encoder operation.
is used to ensure that line speed displays are correct
and programmed pattern measurements are accurate
at all line speeds.
encoder detected, license missing to
enable encoder operation.
Units
C OMPONENTS
 System detects active and/or connected
triggers automatically. Default selection can
be overridden.
Tap down arrow buttons to
select installed components.
 Only triggers that are programmed into the
pattern controller are available for selection in
all screens.
Scaling Procedures
0 - [NONE]
to modify the default settings.
0 - [NONE]
 Tap box or down arrow to select
applicator family from the drop down list.
a. Select ms (milliseconds)
to set patterns in time ONLY.
No scaling needed.
indicates that the selections are
unavailable because of the settings
selected.
b. Select millimeter or inch
to set patterns in distance.
See scaling steps below.
For these procedures, make sure that the line speed is constant.
Scaling using product length
10
 Only applicators that are programmed
into the pattern controller are available for
selection in all the screens.

 Compensation settings are pre-programmed
based on applicator selection.
I NPUTS
6.
Set up system inputs.
b. Tap to select scale by product length.
c. Tap to use different trigger input for the
length measurement.
d. Enter the measured product length
from step a.
 The hourglass symbol appears until
a product is detected on the trigger input.
to modify the default settings.
5.
a. Measure actual product length in line
with where the trigger detects the
product.
e. Run at least one product past the trigger.
O UTPUTS
 The system calculates the resulting
scale.
Set up system outputs.
Scaling using line speed

a. Make sure that the line is running at a
constant speed.
b. Tap to select scale by line speed.
c. Enter the known line speed.
 The system calculates the resulting
scale.
11
Remote Recipe
Selection:
Tap to select each output to:
Remote System Enable:
 Active high (24 VDC)
or
 Active low (0 VDC)
 Set the remote enable
input
to active low (0 VDC)
Tap to check the box for
to
disable
this function.
remote recipes selection.
 Set the remote enable
 The active recipe is
input
to active high
selected using the five
(24
VDC)
to enable this
binary inputs.
function.
Example: 1-1-0-1-0 selects
recipe #11.
7.
Scaling manually
Outputs Icon Status:
Ready

Manual scaling is normally used with one
encoder.

a. Tap to scale manually.
Alert
Fault/Machine
Stop
M ACHINE S ETTINGS
b. Enter the pulse per millimeter (or per
inch) of line travel.
8.
Perform the following steps:
A DDITIONAL M ACHINE S ETTINGS
9.
PASSWORD
Tap to select a single recipe.
Tap to select multiple recipe files.
Tap to select adhesive output on or off when
power is turned on.
Adhesive OFF at power on.
Must be turned on manually.
Adhesive ON at power on.
Tap to set the clock.
Tap
Go to step 8 for Additional Machine Settings.
Tap
. In the numeric keypad enter line
speed when adhesive output
starts.
and
. In the numeric keypad enter line
speed when adhesive output
stops.
Tap the box to enter:
 Trigger timeout time (with no encoder)
or
 Trigger timeout distance (with encoder)
Tap to skip products (like palletizing).
Tap to enable adhesive application when the
line stops, on products that passed the trigger.
Tap to skip adhesive application when the line
stops, on products that passed the trigger.
Original copyright date 2014 S Nordson and the Nordson logo are registered trademarks of Nordson Corporation S Issued 07/14
Tap button, and enter a PIN in the
PIN keypad.
Tap to enable the password function.
Download