CPS Authority LED Surface Module Wiring Diagram

advertisement
Emergency LED Lighting & Equipment
www.cpsauthority.com
Grille and Surface Mount Wire Diagram
T3 / Dual T3 / T4 / Dual T4 / T6 / Dual T6 Modules
NOTES:
Prior to installing the modules, you should take into consideration the position of the
module, routing of wiring, and mounting. The module is weatherproof which can be
installed inside our outside the vehicle. When mounting the module(s), we recommend
predrilling the mounting holes to ease installation. Included with each module are 2
mounting screws. DO NOT over tighten the mounting screws as they could crack the
black cover shroud. Each module has 12 different flash patterns to choose from
including the steady burn feature. You have the ability to sync two modules together so
that they will alternate patterns. (**NOTE** When using SYNC not all flash patterns will
be available).
INSTALLATION:
Prior to installing, you should determine which flash pattern you would like the module
to use. Find access to the easiest power and ground source (vehicle’s battery). Take
each module and apply power to the RED wire and apply ground to the BLACK wire. The
module will turn on. To change the flash patterns, apply GROUND (-) for less than one
second to the BLUE wire. Apply more than one second but less than five seconds; this
will go to the previous flash pattern. Apply more than five seconds will advance to the
default flash pattern. When you find the pattern you like, disconnect the wires and the
unit is ready for installation.
- To sync two modules together perform the following tasks. (**NOTE** When
using SYNC not all flash patterns will be available) Each individual module will need to be
set to the same flash pattern prior to connecting the SYNC wire. If the modules are not
set to the same pattern, they SYNC will not work. Since some of the flash patterns
resemble other patterns, we recommend just finding the steady burn pattern for each
module utilizing the SYNC method. When modules are set to the same pattern disconnect wires from the power
source. Now connect all RED wires together, all BLACK wires together, and all YELLOW wires together. Apply RED
wires to Power (+12v) and apply BLACK wires to GROUND (-). All modules should be displaying the same flash
pattern. If not, STOP disconnect all wires and correct the one module that is different. Now with all modules
displaying the same flash pattern, apply GROUND (-) for less than one second to just one of the BLUE wires. This will
put the modules into sync. Continue advancing through the flash patterns until you find one you like. Again
remember, when using sync not all flash patterns will sync with each other so just continue cycling patterns.
Wire Color
RED
BLACK
BLUE
YELLOW
WHITE
Description
Power
Ground
Pattern Select
Sync
Hi/Low Power
Wiring Code Summary
Trigger Input
(+)12v *Fused at 3 amps*
(-) Ground
(-)Ground – Use momentary (spring loaded) switch
Used to sync multiple units
(+) 12v continuous to activate low power
Download