Emergency LED Lighting & Equipment www.cpsauthority.com Grille and Surface Mount Wire Diagram T3 / Dual T3 / T4 / Dual T4 / T6 / Dual T6 Modules NOTES: Prior to installing the modules, you should take into consideration the position of the module, routing of wiring, and mounting. The module is weatherproof which can be installed inside our outside the vehicle. When mounting the module(s), we recommend predrilling the mounting holes to ease installation. Included with each module are 2 mounting screws. DO NOT over tighten the mounting screws as they could crack the black cover shroud. Each module has 12 different flash patterns to choose from including the steady burn feature. You have the ability to sync two modules together so that they will alternate patterns. (**NOTE** When using SYNC not all flash patterns will be available). INSTALLATION: Prior to installing, you should determine which flash pattern you would like the module to use. Find access to the easiest power and ground source (vehicle’s battery). Take each module and apply power to the RED wire and apply ground to the BLACK wire. The module will turn on. To change the flash patterns, apply GROUND (-) for less than one second to the BLUE wire. Apply more than one second but less than five seconds; this will go to the previous flash pattern. Apply more than five seconds will advance to the default flash pattern. When you find the pattern you like, disconnect the wires and the unit is ready for installation. - To sync two modules together perform the following tasks. (**NOTE** When using SYNC not all flash patterns will be available) Each individual module will need to be set to the same flash pattern prior to connecting the SYNC wire. If the modules are not set to the same pattern, they SYNC will not work. Since some of the flash patterns resemble other patterns, we recommend just finding the steady burn pattern for each module utilizing the SYNC method. When modules are set to the same pattern disconnect wires from the power source. Now connect all RED wires together, all BLACK wires together, and all YELLOW wires together. Apply RED wires to Power (+12v) and apply BLACK wires to GROUND (-). All modules should be displaying the same flash pattern. If not, STOP disconnect all wires and correct the one module that is different. Now with all modules displaying the same flash pattern, apply GROUND (-) for less than one second to just one of the BLUE wires. This will put the modules into sync. Continue advancing through the flash patterns until you find one you like. Again remember, when using sync not all flash patterns will sync with each other so just continue cycling patterns. Wire Color RED BLACK BLUE YELLOW WHITE Description Power Ground Pattern Select Sync Hi/Low Power Wiring Code Summary Trigger Input (+)12v *Fused at 3 amps* (-) Ground (-)Ground – Use momentary (spring loaded) switch Used to sync multiple units (+) 12v continuous to activate low power