3-Way or More Applications (Multi-location) Remote Devices Cat. No. VP00R-10, Coordinating Dimmer Remote Cat. No. VP00R-1L, Matching Dimmer Remote Cat. No. VP0SR-10, Coordinating Switch Remote Cat. No. VP0SR-1L, Matching Switch Remote 120VAC, 60Hz PK-93461-10-00-2A INSTALLATION INSTRUCTIONS WARNINGS AND CAUTIONS: WARNINGS AND CAUTIONS: • To be installed and/or used in accordance with appropriate electrical codes and regulations. • If you are unsure about any part of these instructions, consult a qualified electrician. • To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a transformer-operated appliance. • For Hi-lume® or Eco-10® (EcoSeries) electronic ballast applications, use instruction sheet that comes with the dimmer for multi-location applications. • Vizia +™ remotes are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia +™ or Vizia rf +™ devices for multi-location switching. • Use only one (1) Vizia +™ dimmer in a multi-location circuit with up to 9 coordinating remotes without LEDs or up to 4 matching remotes with LEDs. The remote(s) will turn the light on at the brightness level selected at the dimmer. • Recommended minimum wall box depth is 2-1/2". • Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft (90 m). • Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture. • Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL. Tools needed to install your Remote: Slotted/Phillips Screwdriver Pliers Cutters Step 4b 3-Way Wiring with Coordinating Remote (no LEDs) Application: Step 2 cont’d Electrical Tape Pencil Ruler NOTE: Incandescent and Magnetic Low Voltage installations only. NOTE: Screw terminal dimmer depicted. Changing the color of your Device: Your device may include color options. To change color of the face proceed as follows: Dimmer Coordinating Remote Side Wire Connection Side wire terminals accept #14 AWG solid copper wire only. Back Wire (either hole may be used) Back wire openings use #14-12 AWG solid copper wire only. Bk Terminal Screw marked Black (Bk) 2 4 4 Push in side at tab to release not used INSTALLING YOUR REMOTE NOTE: Use check boxes when Steps are completed. Step 1 3-Way Wiring with Matching Remote (w/LEDs) Application: Step 4a NOTE: Incandescent and Magnetic Low Voltage installations only. NOTE: Screw terminal dimmer depicted. WARNING: To avoid fire, shock, or death; turn off power at circuit breaker or fuse and test that power is off before wiring! Matching Remote Terminal Screw marked White (Wh) /&& /. /&& /. /&& /. /&& /. Dimmer /&& /. /&& /. /&& /. /&& /. /&& /. /&& /. /&& /. /&& /. Step 2 Additional Neutral Wire 4 Bk 2 4 3 3 YL/RD RD 1 5 YL/RD RD 5 Identifying your wiring application (most common): NOTE: If the wiring in the wall box does not resemble any of these configurations, consult a qualified electrician. Matching Remote (w/LEDs) hot (Black) Wh Dimmer Bk Bk Green Ground Line 120vAC, 60hz YL/RD Green Ground RD Black YL/RD Load White 2 1 1 3 2 4 5 6 3 4 5 3-Way 1. Line or Load (See important instruction below) 2. Neutral 3. Ground 4. First Traveler – note color 5. Second Traveler – note color NOTE: For matching remote w/LEDs installation, the First Traveler becomes Line Hot. 4-Way 1. First Traveler – note color 2. Second Traveler – tagged 3. Neutral 4. Ground 5. Third Traveler – note color 6. Fourth Traveler – tagged NOTE: For matching remote w/LEDs installation, the First Traveler becomes Line Hot. IMPORTANT: For 3-Way applications, note that one of the screw terminals from the old switch being removed will usually be a different color (Black) or labeled Common. Tag that wire with electrical tape and identify as the common (Line or Load) in both the dimmer wall box and remote wall box. For 4-Way applications, note that the old switch being removed will have 4 screws plus a ground screw. Tag the two same color insulated wires with electrical tape. Step 3 Preparing and connecting wires: This remote can be wired using side wire terminal screws or through backwire openings. Choose appropriate wire stripping specifications accordingly. RD Load YL/RD YL/RD RD Neutral (White) NOTE: The dimmer must be installed in a wall box that has a Load connection. The matching remote must be installed in a wall box with a Line Hot connection and a Neutral connection. A Neutral wire to the matching remote needs to be added as shown. If you are unsure about any part of these instructions, consult a qualified electrician. NOTE: Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft. Wiring Matching Remote (wall box with Line Hot connection): Connect wires per WIRING DIAGRAM as follows: • Green or bare copper wire in wall box to Green terminal screw. • Line Hot (common) wall box wire identified (tagged) when removing old switch and First Traveler to remote terminal screw marked “BK” or the Black dimmer lead. • Second Traveler wall box wire from dimmer to remote terminal screw marked “YL/RD” (note wire color). This traveler from the remote must go to the terminal screw on the dimmer marked “YL/RD” or the Yellow/Red dimmer lead. • Line Neutral wall box to remote terminal screw marked “WH”. Line 120vAC, 60hz White Connect wires per WIRING DIAGRAM as follows: NOTE: When using the coordinating remote without LEDs, the dimmer can be installed on either the Line or Load side of the 3-way circuit. NOTE: Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft (90 m). • Green or bare copper wire in wall box to Green terminal screw or Green dimmer lead. • Line Hot (common) wall box wire identified (tagged) when removing old switch to dimmer terminal screw marked "BK" or Black dimmer lead. • First Traveler wall box wire to terminal screw marked "RD" or Red dimmer lead (note wire color). This traveler from the dimmer must go to the terminal screw on the remote marked "RD". • Remove Red insulating label from terminal screw marked "YL/RD" or Yellow/Red dimmer lead. • Second Traveler wall box wire to terminal screw marked "YL/RD" or Yellow/Red dimmer lead (note wire color). This traveler from the dimmer must go to the terminal screw on the remote marked "YL/RD". 3-Way Wiring with Matching Remote (w/LEDs) for Controls with Neutral Connection Application: NOTE: Electronic Low Voltage, Mark 10™, Quiet Fan Speed and Electronic Switch installations only. NOTE: Dimmer is depicted. Matching Remote Terminal Screw marked White (WH) Additional Neutral Wire YL/RD Step 4d Black 1 4 2 White 4 Terminal Screw marked Yellow/Red (YL/RD) 3 YL/RD RD Red 1 3 5 5 Yellow/Red Matching Remote (w/LEDs) Control Hot (Black) WH BK White Line 120VAC, 60Hz YL/RD Black Green Ground Red Black Yellow/Red Load White Neutral (White) RD YL/RD 3-Way Wiring with Coordinating Remote (no LEDs) for Controls with Neutral Connection Application: NOTE: Electronic Low Voltage, Mark 10™, Quiet Fan Speed and Electronic Switch installations only. NOTE: Dimmer is depicted. Line 120vAC, 60hz Terminal Screw marked White (WH) 2 2 Green 3 4 3 5 Red Terminal Screw marked Yellow/Red (YL/RD) Yellow/Red RD not used Load BK not used Green Ground Black 4 RD YL/RD Load Wiring Matching Remote (4-Way wall box with Line Hot connection): 5 Coordinating Remote (no LEDs) WH YL/RD RD NOTE: The dimmer must be installed in a wall box that has a Load connection. The matching remote must be installed in a wall box with a Line Hot connection and a Neutral connection. A Neutral wire to the matching remote needs to be added as shown. If you are unsure about any part of these instructions, consult a qualified electrician. NOTE: Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft (90 m). White RD YL/RD YL/RD Neutral (White) 1 BK YL/RD RD White Black 1 Bk Control Coordinating Remote YL/RD Control White Hot (Black) Black Green Ground Red YL/RD Line 120VAC, 60Hz White WIRING CONTROL: Green 4-Way Wiring with Matching Remote (w/LEDs) Application: Bk Neutral (White) 2 BK Terminal Screw marked Black (BK) Control Step 5a Bk Connect wires per WIRING DIAGRAM as follows: NOTE: Maximum wire length from dimmer to last remote is 300 ft (90 m). • Green or bare copper wire in wall box to Green terminal screw. • Load wall box wire identified (tagged) when removing old switch to terminal screw marked "BK". • First Traveler wall box wire (note color as above) to terminal screw marked "RD". This traveler from the remote must go to the terminal screw on the dimmer marked "RD" or Red dimmer lead. • Second Traveler wall box wire (note color as above) to terminal screw marked "YL/RD". This traveler from the remote must go to the terminal screw on the dimmer marked "YL/RD" or Yellow/Red dimmer lead. • Remote terminal screw marked "WH" should have White insulation label affixed. NOTE: If insulating label is not affixed to terminal screw marked "WH", use electrical tape to cover. • Proceed to Step 6. Step 4c Connect wires per WIRING DIAGRAM as follows: NOTE: "BK" and "RD" terminals on coordinating remote are unused. Tighten both screws. NOTE: Maximum wire length from control to last remote is 300 ft (90 m). • Green or bare copper wire in wall box to Green terminal screw. • Load wall box wire identified (tagged) when removing old switch to First Traveler (note color as above). • Second Traveler wall box wire (note color as above) to terminal screw marked "YL/RD". This traveler from the remote must go to the terminal screw marked "YL/RD" or Yellow/Red control lead. • Remove White insulating label from terminal screw marked "WH". • Line Neutral wall box wire to terminal screw marked "WH". • Proceed to Step 6. NOTE: Incandescent and Magnetic Low Voltage Connect wires per WIRING DIAGRAM as follows: installations only. • Green or bare copper wire in wall box to Green terminal screw or NOTE: Screw terminal dimmer depicted. Green control lead. Dimmer Matching Remote Matching Remote • Load wall box wire identified (3-Way Wall box from Step 2) (4-Way Wall box from Step 2) (3-Way Wall box from Step 2) (tagged) when removing old switch Terminal Terminal Additional Screw marked Screw marked Additional Neutral Wire to terminal screw marked "RD" or White (Wh) White (Wh) Neutral Wire Red control lead. 4 2 3 Terminal • First Traveler Line Hot to terminal 1 Terminal 1 Screw marked Screw marked 2 Black (Bk) screw marked "BK" or Black Black (Bk) 5 4 3 control lead. 3 Terminal 4 Terminal Screw marked 1 2 Screw marked • Remove Red insulating label from Yellow/Red 5 Yellow/Red (YL/RD) 5 6 (YL/RD) terminal screw marked "YL/RD" or Yellow/Red control lead. • Second Traveler wall box wire (note color as above) to terminal screw marked "YL/RD" or Yellow/Red control lead. This traveler from the control must go to the terminal screw on the remote Matching Remote Matching Remote Dimmer (w/LEDs) (w/LEDs) marked "YL/RD". • Line neutral wall box wire to terminal screw marked "WH" or hot (Black) Bk Wh Wh Bk White control lead. Bk Green Green Green • Proceed to Step 6. Black Ground Ground Ground WIRING COORDINATING REMOTE: Wiring Dimmer (wall box with Load connection): Connect wires per WIRING DIAGRAM as follows: • Green or bare copper wire in wall box to Green terminal screw or Green dimmer lead. • Load wall box wire identified (tagged) when removing old switch to dimmer terminal screw marked “RD” or the Red dimmer lead. • First Traveler Line Hot to dimmer terminal screw marked “BK” or the Black dimmer lead. • Remove Red insulating label from terminal screw marked “YL/RD” or Yellow/Red dimmer lead. • Second Traveler wall box wire (note color as above) to dimmer terminal screw marked “YL/RD” or the Yellow/Red dimmer lead. This traveler from the dimmer must go to the terminal screw on the remote marked “YL/RD”. • Proceed to Step 6. Connect wires per WIRING DIAGRAM as follows: • Green or bare copper wire in wall box to Green terminal screw. • Line Hot (common) wall box wire identified (tagged) when removing old switch and First Traveler to terminal screw marked "BK" or Black dimmer lead. • Second Traveler wall box wire from control to remote terminal screw marked "YL/RD" (note wire color). This traveler from the remote must go to terminal screw marked "YL/RD" or Yellow/Red control lead. • Line Neutral wall box to remote terminal screw marked "WH". Step 4d cont’d WIRING COORDINATING REMOTE: Wiring Dimmer (wall box with Load connection): Green Ground Green Ground Cut (if necessary) hot (Black) Bk Green Ground WIRING DIMMER: 1 Terminal Screw marked Yellow/Red (YL/RD) Bk Wh Black Neutral (White) Dimmer 2 Bk Terminal Screw marked Black (Bk) 5 Terminal Screw marked Red (RD) Strip Gage (measure bare wire here or use gage on back of the dimmer) • Make sure that the ends of the wires from the wall box are straight (cut if necessary). • Remove insulation from each wire in the wall box as shown. RD YL/RD 5 Coordinating Remote (no LEDs) Line up tabs and press in sides one at a time to attach 2 3 RD YL/RD Wiring Matching Remote (wall box with Line Hot connection): 1 3 Terminal Screw marked Yellow/Red (YL/RD) 5/8" (1.6 cm) Bk 1 NOTE: The control must be installed in a wall box that has a Load connection. The matching remote must be installed in a wall box with a Line Hot connection and a Neutral connection. A Neutral wire to the matching remote needs to be added as shown. If you are unsure about any part of these instructions, consult a qualified electrician. NOTE: Maximum wire length from control to all installed remotes cannot exceed 300 ft (90 m). Connect wires per WIRING DIAGRAM as follows: NOTE: The control must be installed in a wall box that has a Line Hot Connection. NOTE: Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft (90 m). • Green or bare copper wire in wall box to Green terminal screw or Green control lead. • Line Hot (common) wall box wire identified (tagged) when removing old switch to terminal screw marked "BK" or Black control lead. • First Traveler wall box wire to terminal screw marked "RD" or Red control lead (note wire color). • Remove Red insulating label from terminal screw marked "YL/RD" or Yellow/Red control lead. • Second Traveler wall box wire to terminal screw marked "YL/RD" or Yellow/Red control lead (note wire color). This traveler from the control must go to the terminal screw on the remote marked "YL/RD". • Line Neutral wall box wire to terminal screw marked "WH" or White control lead. Connect wires per WIRING DIAGRAM as follows: • Green or bare copper wire in wall box to Green terminal screw. • First Traveler and Third Traveler wall box wire from dimmer in the 3-way box to remote terminal screw marked "BK" in the 4-way box, and to the terminal screw marked "BK" of the remaining remote in the 3-way box. • Second Traveler (tagged) and Fourth Traveler (tagged) wall box wire from dimmer in the 3-way box to remote terminal screw marked "YL/RD" in the 4-way box, and to the terminal screw marked "YL/RD" of the remaining remote in the 3-way box (note wire colors). This traveler from the remotes must go to the terminal screw on the dimmer marked "YL/RD" or the Yellow/Red dimmer lead. • Line Neutral wall box wire to remote terminal screw marked "WH". Wiring MATCHING REMOTE (3-Way wall box with Line Hot connection): Connect wires per WIRING DIAGRAM as follows: • Green or bare copper wire in wall box to Green terminal screw. • Line Hot (common) wall box wire identified (tagged) when removing old switch and First Traveler dimmer terminal screw marked "BK" or the Black dimmer lead. • Second Traveler wall box wire from dimmer to remote terminal screw marked "YL/RD" (note wire color as above). This traveler from the remote must go to the terminal screw on the dimmer marked "YL/RD" or the Yellow/Red dimmer lead. • Line Neutral wall box wire to remote terminal screw marked "WH". 4-Way Wiring with Matching Remote (w/LEDs) Application: Step 5a cont’d NOTE: Electronic Low Voltage, Mark 10™, Quiet Fan Speed and Electronic Switch installations only. NOTE: Dimmer is depicted. Wiring Dimmer (3-Way wall box with Load connection): Connect wires per WIRING DIAGRAM as follows: • Green or bare copper wire in wall box to Green terminal screw or Green dimmer lead. • Load wall box wire identified (tagged) when removing old switch to dimmer terminal screw marked "RD" or the Red dimmer lead. • First Traveler Line Hot to dimmer terminal screw marked "BK" or the Black dimmer lead. • Remove Red insulating label from terminal screw marked "YL/RD" or the Yellow/ Red dimmer lead. • Second Traveler wall box wire (note color as above) to dimmer terminal screw marked "YL/RD" or the Yellow/Red dimmer lead. This traveler from the dimmer must go to the terminal screw on the remote marked "YL/RD". • Proceed to Step 6. Step 5b 4-Way Wiring with Coordinating Remote (no LEDs) Application: Terminal Screw marked Black (BK) Terminal Screw marked Yellow/Red (YL/RD) BK RD YL/RD WH NOTE: The control must be installed in a wall box that has a Load connection. The matching remote must be installed in a wall box with a Line Hot connection and a Neutral connection. A Neutral wire to the matching remote needs to be added as shown. If you are unsure about any part of these instructions, consult a qualified electrician. NOTE: Maximum wire length from control to all installed remotes cannot exceed 300 ft (90 m). Connect wires per WIRING DIAGRAM as follows: NOTE: The control must be installed in a wall box that has a Line Hot connection. NOTE: Maximum wire length from control to all installed remotes cannot exceed 300 ft (90 m). • Green or bare copper wire in wall box to Green terminal screw or Green control lead. • Line Hot (common) wall box wire identified (tagged) when removing old switch to terminal screw marked "BK" or Black control lead. • First Traveler wall box wire to terminal screw marked "RD" or Red control lead (note wire color as above). • Remove Red insulating label from terminal screw marked "YL/RD" or Yellow/Red control lead. • Second Traveler wall box wire to terminal screw marked "YL/RD" or Yellow/Red control lead (note wire color as above). This traveler from the control must go to the terminal screw on the remote marked "YL/RD". • Line Neutral wall box wire to terminal screw marked "WH" or White control lead. Wiring Matching Remote (4-Way wall box with Line Hot connection): WIRING COORDINATING REMOTE (3-Way box): Green Ground Green Ground Black Yellow/Red Red YL/RD YL/RD Line 120VAC, 60Hz Terminal Screw marked Yellow/Red (YL/RD) Bk YL/RD 1 Load 3 4 4 1 RD YL/RD 5 Load Wh RD 2 3 5 4 2 6 YL/RD Coordinating Remote (no LEDs) Bk not used Wh Green Ground RD 1 RD 5 Terminal Screw marked Yellow/Red (YL/RD) Coordinating Remote (no LEDs) not used Neutral (White) Bk 3 Terminal Screw marked Red (RD) Black White Bk 2 YL/RD RD Dimmer hot (Black) not used Bk Green Ground Green Ground Bk YL/RD RD YL/RD Line 120vAC, 60hz White Neutral (White) WIRING COORDINATING REMOTE (4-Way box): Connect wires per WIRING DIAGRAM as follows: NOTE: Maximum wire length from dimmer to last remote is 300 ft (90 m). • Green or bare copper wire in wall box to Green terminal screw. • First Traveler and Third Traveler wall box wire (note wire colors) to terminal screw marked "RD". These travelers from the remote in the 4-way box must go to the terminal screw on the dimmer marked "RD" or Red dimmer lead, and to the terminal screw marked "RD" of the remaining remote in the 3-way box. • Second Traveler (tagged) and Fourth Traveler (tagged) wall box wire (note wire colors) to terminal screw marked "YL/RD". These travelers from the remote in the 4-way box must go to the terminal screw on the dimmer marked "YL/RD" or the Yellow/Red dimmer lead, and to the terminal screw marked "YL/RD" of the remaining remote in the 3-way box. • Remote terminal screw marked "WH" should have White insulation label affixed. NOTE: If insulating label is not affixed to terminal screw marked "WH", use electrical tape to cover. Remote terminal screw marked "BK" is not used. Use electrical tape to cover. WIRING DIMMER (3-Way box): Connect wires per WIRING DIAGRAM as follows: NOTE: When using the coordinating remote without LEDs, the dimmer can be installed on either the Line or Load side of the 3-way circuit. NOTE: Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft (90 m). • Green or bare copper wire in wall box to Green terminal screw or Green dimmer lead. • Line Hot (common) wall box wire identified (tagged) when removing old switch to dimmer terminal screw marked "BK" or Black dimmer lead. • First Traveler wall box wire to dimmer terminal screw marked "RD" or Red dimmer lead (note wire color as above). This traveler from the dimmer must go to the terminal screw on the remote marked "RD". • Remove Red insulating label from terminal screw marked "YL/RD" or Yellow/Red dimmer lead. • Second Traveler wall box wire to dimmer terminal screw marked "YL/RD" or Yellow/ Red dimmer lead (note wire color as above). This traveler from the dimmer must go to the terminal screw on the remote marked "YL/RD". WIRING COORDINATING REMOTE (3-Way box): Connect wires per WIRING DIAGRAM as follows: NOTE: Maximum wire length from dimmer to last remote is 300 ft (90 m). • Green or bare copper wire in wall box to Green terminal screw. • Load wall box wire identified (tagged) when removing old switch to terminal screw marked "BK". • First Traveler wall box wire (note color as above) to terminal screw marked "RD". This traveler from the remote must go to the terminal screw on the dimmer marked "RD" or the Red dimmer lead. • Second Traveler wall box wire (note color as above) to terminal screw marked "YL/RD". This traveler from the remote must go to the terminal screw on the dimmer marked "YL/RD" or the Yellow/Red dimmer lead. • Remote terminal screw marked "WH" should have White insulation label affixed. NOTE: If insulating label is not affixed to terminal screw marked "WH", use electrical tape to cover. • Proceed to Step 6. Connect wires per WIRING DIAGRAM as follows: • Green or bare copper wire in wall box to Green terminal screw. • First Traveler and Third Traveler wall box wire to remote terminal screw marked "BK" in 4-way box, and to terminal screw marked "BK" of the remaining remote in 3-way box. • Second Traveler (tagged) and Fourth Traveler (tagged) wall box wire from control in 3-way box to remote terminal screw marked "YL/RD" in 4-way box and to terminal screw marked "YL/RD" of the remaining remote in 3-way box (note wire colors). This traveler from the remotes must go to the terminal screw marked "YL/RD" or Yellow/Red control lead. • Line Neutral wall box wire to remote terminal screw marked "WH". Wiring MATCHING REMOTE (3-Way wall box with Line Hot connection): Connect wires per WIRING DIAGRAM as follows: • Green or bare copper wire in wall box to Green terminal screw. • Line Hot (common) wall box wire identified (tagged) when removing old switch and First Traveler wall box wire to control terminal screw marked "BK" or Black dimmer lead. • Second Traveler wall box wire from control to remote terminal screw marked "YL/RD" (note wire color as above). This traveler from the remote must go to the terminal screw marked "YL/RD" or Yellow/Red dimmer lead. • Line Neutral wall box wire to remote terminal screw marked "WH". Connect wires per WIRING DIAGRAM as follows: NOTE: "BK" and "RD" terminals on coordinating remote are unused. Tighten both screws. NOTE: Maximum wire length from control to last remote is 300 ft (90 m). • Green or bare copper wire in wall box to Green terminal screw. • Load wall box wire identified (tagged) when removing old switch to First Traveler (note color as above). • Second Traveler wall box wire (note color as above) to terminal screw marked "YL/RD". This traveler from the remote must go to the terminal screw marked "YL/RD" or Yellow/Red control lead. • Remove White insulating label from terminal screw marked "WH". • Line Neutral wall box wire to terminal screw marked "WH". • Proceed to Step 6. Step 6 Testing your Remote prior to completely mounting in wall box: • Position all wires to provide room in outlet wall box for device. • Ensure that the word "TOP" is facing up on the device strap. • Partially screw in mounting screws in wall box mounting hole. Wiring CONTROL (3-Way wall box with Load connection): Connect wires per WIRING DIAGRAM as follows: • Green or bare copper wire in wall box to Green terminal screw or Green dimmer lead. • Load wall box wire identified (tagged) when removing old switch to terminal screw marked "RD" or Red control lead. • First Traveler Line Hot to terminal screw marked "BK" or Black control lead. • Remove Red insulating label from terminal screw marked "YL/RD" or Yellow/Red control lead. • Second Traveler wall box wire (note color as above) to terminal screw marked "YL/RD" or Yellow/Red control lead. This traveler from the control must go to the terminal screw on the remote marked "YL/RD". • Line Neutral wall box wire to terminal screw marked "WH" or White control lead. • Proceed to Step 6. Step 5d Coordinating Remote (4-Way Box from Step 2) Control (3-Way Wall Box from Step 2) Terminal Screw marked White (WH) Terminal Screw marked Yellow/Red (YL/RD) BK 3 1 Terminal Screw marked Black (BK) 2 Terminal Screw marked Yellow/Red (YL/RD) 4 YL/RD RD 5 BK 1 2 2 1 NOTE: Dress wires with a bend as shown in diagram in order to relieve stress when mounting device. • Restore power at circuit breaker or fuse. • See applicable operation section to ensure dimmer or switch is functioning properly. • If lights do not turn ON, refer to the TROUBLESHOOTING section. Green 5 RD 3 6 Red Yellow/Red 4 5 Coordinating Remote (no LEDs) WH not used Coordinating Remote (no LEDs) WH Green Ground Black RD not used Load BK YL/RD BK not used Green Ground RD not used YL/RD Locator Light VP0SR Switch Remote Operation (Device may be unlighted): The lighting can be switched from either the dimmer or the remote location. Push Pad (Default settings) Turn ON from OFF position: Tap – Lights turn ON to preset level. Turn OFF from ON position: Tap – Lights turn OFF. In the event of power outage or interruption the lights will reset to the last level when power is restored. Push Pad Locator Light VP00R-1L ADVANCED PROGRAMMING FEATURES FOR USE WITH VIZIA RF +™ ONLY Definition of A Modes A)LED Options: Sets single LED (default) or LED Bar to display the load status. Program Mode A To enter Program Mode A: Press and hold the Push Pad and then the right half of the DIM/BRIGHT Bar (^) for 5 seconds until all LEDs blink. Upon releasing the Push Pad Locator LED will blink once per second to indicate Program Mode A, LED Options. To change the LED Options settings, release the Push Pad. This setting will automatically be saved and the device will exit Programming Mode. LED Options LED Brightness/Fan Speed Display Default Single LED First toggle LED Bar Lights Flickering - Lamp has a bad connection. - Wires not secured firmly under terminal screws of dimmer and/or remote. Light does not turn ON and Locator LED does not turn ON - Circuit breaker or fuse has tripped. - Lamp is burned out. - Lamp Neutral connection is not wired. Intermittent dimmer operation - Minimum load is under 40W. Remote does not operate lights - Ensure that total wire length does not exceed 300 ft (90 m). - Ensure that only Coordinating Remotes are used with Vizia rf +™ devices White 3 4 YL/RD DIM/BRIGHT Bar Push Pad (Default settings) Turn ON from OFF position: Tap – Lights turn ON to preset level. Press and Hold – Lights turn ON to full bright. Turn OFF from ON position: Tap – Lights turn OFF. DIM/BRIGHT Bar BRIGHTEN: Press right half of DIM/BRIGHT Bar – Lights brighten to desired level. DIM: Press left half of DIM/BRIGHT Bar – Lights dim to desired level. If you continue to hold, the lights will DIM to minimum level and then turn OFF. In the event of power outage or interruption the lights will reset to the last level when power is restored. For additional information, contact Leviton’s Techline at 1-800-824-3005 or visit Leviton’s website at www.leviton.com Black Terminal Screw marked Black (BK) Push Pad • • • • NOTE: Electronic Low Voltage, Mark 10™, Quiet Fan Speed and Electronic Switch installations only. NOTE: Dimmer is depicted. Terminal Screw marked White (WH) LED Brightness Display TROUBLESHOOTING 4-Way Wiring with Coordinating Remote (no LEDs) for Controls with Neutral Connection Application: Coordinating Remote (3-Way Wall box from Step 2) VP00R Dimmer Remote Operation (Device may be unlighted): NOTE: The lights will turn ON at brightness set on dimmer’s DIM/BRIGHT bar. The lighting can be switched from either the dimmer or the remote location. WIRING CONTROL (3-Way box): Black White BK WH BK CLEANING: Clean with a damp cloth. DO NOT use chemical cleaners. RD YL/RD Terminal Screw marked Red (RD) Terminal Screw marked Black (Bk) WIRING COORDINATING REMOTE (4-Way box): BK Green Ground Coordinating Remote Dimmer (4-Way Box from Step 2) (3-Way Wall Box from Step 2) OPERATION Step 5d cont’d Connect wires per WIRING DIAGRAM as follows: NOTE: "BK" and "RD" terminals on coordinating remote are unused. Tighten both screws. Matching Remote Matching Remote Control (3-Way Wall box from Step 2) (4-Way Wall box from Step 2) (3-Way Wall Box from Step 2) NOTE: Maximum wire length from dimmer to last remote is 300 ft (90 m). Terminal Terminal Green Additional Screw marked Screw marked Additional • Green or bare copper wire in wall box to Green terminal screw. Neutral Wire White (WH) White (WH) Neutral Wire Black • Connect First Traveler wall box wire to Third Traveler wall box wire (note wire colors) 4 2 3 to terminal screw marked "RD" of remote in 4-way box, and to terminal screw marked 1 Terminal 1 2 Screw marked White Black (BK) "RD" of the remaining remote in 3-way box. 5 4 3 4 • Connect Second Traveler and Fourth Traveler wall box wire (note wire colors) to Terminal 3 Red 2 1 Screw marked 5 Yellow/Red terminal screw marked "YL/RD" of remote in 4-way box, and to terminal screw marked 6 (YL/RD) "YL/RD" of the remaining remote in 3-way box. 5 Yellow/Red This traveler from the remotes must go to the terminal screw marked "YL/RD" or Yellow/Red control lead. • Remove White insulating label from terminal screw marked "WH". Matching Remote Matching Remote Control • Line Neutral wall box wire to terminal screw marked "WH". (w/LEDs) (w/LEDs) Hot (Black) NOTE: Incandescent and Magnetic Low Voltage installations only. NOTE: Screw terminal dimmer depicted. Coordinating Remote (3-Way Wall box from Step 2) 4-Way Wiring with Matching Remote (w/LEDs) for Controls with Neutral Connection Application: Step 5c Step 7 Dimmer Remote Mounting: Control White Turn off power at circuit breaker or fuse. Hot (Black) Black Green Ground Red YL/RD Line 120VAC, 60Hz Installation may now be completed by tightening mounting screws into wall box. Attach wallplate. White Neutral (White) Step 8 Restore Power: Covered by one or more US & Foreign Patents and patents pending Copyright© 2007 Leviton Manufacturing Co., Inc. All Rights Including Trade Dress Rights Reserved Eco-10™ (Eco Series) is a trademark and Hi-lume® is a registered trademark of Lutron Electronics Inc. FCC COMPLIANCE STATEMENT This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment OFF and ON, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving Antenna. • Increase the separation between the equipment and the receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/tv technician for help. Restore power at circuit breaker or fuse. Installation is complete. PK-93461-10-00-2A LIMITED 5 YEAR WARRANTY AND EXCLUSIONS Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.