WARNINGS AND CAUTIONS:
WARNINGS AND CAUTIONS:
• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are unsure about any part of these instructions, consult a qualified electrician.
• To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a
transformer-operated appliance.
• For Hi-lume® or Eco-10® (EcoSeries) electronic ballast applications, use instruction sheet that comes with the dimmer for multi-location applications.
• Vizia +™ remotes are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia +™ or Vizia rf +™ devices for multi-location
switching.
• Use only one (1) Vizia +™ dimmer in a multi-location circuit with up to 9 coordinating remotes without LEDs or up to 4 matching remotes with LEDs. The remote(s)
will turn the light on at the brightness level selected at the dimmer.
• Recommended minimum wall box depth is 2-1/2".
• Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft (90 m).
• Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
• Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.
Tools needed to install your Remote:
Slotted/Phillips Screwdriver
Pliers
Cutters
Step 4b 3-Way Wiring with Coordinating Remote (no LEDs)
Application:
Step 2 cont’d
Electrical Tape
Pencil
Ruler
NOTE: Incandescent and Magnetic Low Voltage
installations only. NOTE: Screw terminal dimmer
depicted.
Changing the color of your Device:
Your device may include color options. To change color of the face
proceed as follows:
Dimmer
Coordinating Remote
Side Wire Connection
Side wire terminals accept
#14 AWG solid copper wire
only.
Back Wire
(either hole may be used)
Back wire openings use
#14-12 AWG solid copper wire only.
Bk
Terminal
Screw marked
Black (Bk)
2
4
4
Push in side at tab
to release
not used
INSTALLING YOUR REMOTE
NOTE: Use check boxes when Steps are completed.
Step 1
3-Way Wiring with Matching Remote (w/LEDs)
Application:
Step 4a
NOTE: Incandescent and Magnetic Low Voltage
installations only.
NOTE: Screw terminal dimmer depicted.
WARNING: To avoid fire, shock, or death;
turn off power at circuit breaker or fuse and test
that power is off before wiring!
Matching Remote
Terminal
Screw marked
White (Wh)
/&&
/.
/&&
/.
/&&
/.
/&&
/.
Dimmer
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
Step 2
Additional
Neutral Wire
4
Bk
2
4
3
3
YL/RD
RD
1
5
YL/RD
RD
5
Identifying your wiring application (most
common):
NOTE: If the wiring in the wall box does not resemble
any of these configurations, consult a qualified
electrician.
Matching Remote (w/LEDs)
hot (Black)
Wh
Dimmer
Bk
Bk
Green
Ground
Line
120vAC, 60hz
YL/RD
Green
Ground
RD
Black
YL/RD
Load
White
2
1
1
3
2
4
5
6
3
4
5
3-Way
1. Line or Load (See important instruction below)
2. Neutral
3. Ground
4. First Traveler – note color
5. Second Traveler – note color
NOTE: For matching remote
w/LEDs installation, the First
Traveler becomes Line Hot.
4-Way
1. First Traveler – note color
2. Second Traveler – tagged
3. Neutral
4. Ground
5. Third Traveler – note color
6. Fourth Traveler – tagged
NOTE: For matching remote
w/LEDs installation, the First
Traveler becomes Line Hot.
IMPORTANT:
For 3-Way applications, note that one of the screw terminals from
the old switch being removed will usually be a different color (Black)
or labeled Common. Tag that wire with electrical tape and identify
as the common (Line or Load) in both the dimmer wall box and
remote wall box.
For 4-Way applications, note that the old switch being removed
will have 4 screws plus a ground screw. Tag the two same color
insulated wires with electrical tape.
Step 3
Preparing and connecting wires:
This remote can be wired using side wire terminal
screws or through backwire openings. Choose
appropriate wire stripping specifications accordingly.
RD
Load
YL/RD
YL/RD
RD
Neutral (White)
NOTE: The dimmer must be installed in a wall box that has a Load
connection. The matching remote must be installed in a wall box with
a Line Hot connection and a Neutral connection. A Neutral wire to the
matching remote needs to be added as shown.
If you are unsure about any part of these instructions, consult a
qualified electrician.
NOTE: Maximum wire length from dimmer to all installed remotes
cannot exceed 300 ft.
Wiring Matching Remote (wall box with Line Hot
connection):
Connect wires per WIRING DIAGRAM as follows:
• Green or bare copper wire in wall box to Green terminal screw.
• Line Hot (common) wall box wire identified (tagged) when removing old switch and First Traveler to remote terminal screw marked “BK”
or the Black dimmer lead.
• Second Traveler wall box wire from dimmer to remote terminal
screw marked “YL/RD” (note wire color). This traveler from the
remote must go to the terminal screw on the dimmer marked
“YL/RD” or the Yellow/Red dimmer lead.
• Line Neutral wall box to remote terminal screw marked “WH”.
Line
120vAC, 60hz
White
Connect wires per WIRING DIAGRAM as follows:
NOTE: When using the coordinating remote without LEDs, the dimmer
can be installed on either the Line or Load side of the 3-way circuit.
NOTE: Maximum wire length from dimmer to all installed remotes
cannot exceed 300 ft (90 m).
• Green or bare copper wire in wall box to Green terminal screw or Green dimmer lead.
• Line Hot (common) wall box wire identified (tagged) when removing
old switch to dimmer terminal screw marked "BK" or Black dimmer
lead.
• First Traveler wall box wire to terminal screw marked "RD" or Red dimmer lead (note wire color). This traveler from the dimmer must
go to the terminal screw on the remote marked "RD".
• Remove Red insulating label from terminal screw marked
"YL/RD" or Yellow/Red dimmer lead.
• Second Traveler wall box wire to terminal screw marked "YL/RD" or
Yellow/Red dimmer lead (note wire color). This traveler from the
dimmer must go to the terminal screw on the remote marked "YL/RD".
3-Way Wiring with Matching Remote
(w/LEDs) for Controls with Neutral Connection
Application:
NOTE: Electronic Low Voltage, Mark 10™, Quiet Fan
Speed and Electronic Switch installations only.
NOTE: Dimmer is depicted.
Matching Remote
Terminal
Screw marked
White (WH)
Additional
Neutral Wire
YL/RD
Step 4d
Black
1
4
2
White
4
Terminal
Screw marked
Yellow/Red
(YL/RD)
3
YL/RD
RD
Red
1
3
5
5
Yellow/Red
Matching Remote (w/LEDs) Control
Hot (Black)
WH
BK
White
Line
120VAC, 60Hz
YL/RD
Black
Green
Ground
Red
Black
Yellow/Red
Load
White
Neutral (White)
RD
YL/RD
3-Way Wiring with Coordinating Remote (no
LEDs) for Controls with Neutral Connection
Application:
NOTE: Electronic Low Voltage, Mark 10™, Quiet
Fan Speed and Electronic Switch installations only.
NOTE: Dimmer is depicted.
Line
120vAC, 60hz
Terminal
Screw marked
White (WH)
2
2
Green
3
4
3
5
Red
Terminal
Screw marked
Yellow/Red
(YL/RD)
Yellow/Red
RD
not used
Load
BK
not used
Green
Ground
Black
4
RD
YL/RD
Load
Wiring Matching Remote (4-Way wall box with Line
Hot connection):
5
Coordinating Remote (no LEDs)
WH
YL/RD
RD
NOTE: The dimmer must be installed in a wall box that has a Load
connection. The matching remote must be installed in a wall box
with a Line Hot connection and a Neutral connection. A Neutral wire
to the matching remote needs to be added as shown.
If you are unsure about any part of these instructions, consult a
qualified electrician.
NOTE: Maximum wire length from dimmer to all installed remotes
cannot exceed 300 ft (90 m).
White
RD
YL/RD
YL/RD
Neutral (White)
1
BK
YL/RD
RD
White
Black
1
Bk
Control
Coordinating Remote
YL/RD
Control
White
Hot (Black)
Black
Green
Ground
Red
YL/RD
Line
120VAC, 60Hz
White
WIRING CONTROL:
Green
4-Way Wiring with Matching Remote (w/LEDs)
Application:
Bk
Neutral (White)
2
BK
Terminal
Screw marked
Black (BK)
Control
Step 5a
Bk
Connect wires per WIRING DIAGRAM as follows:
NOTE: Maximum wire length from dimmer to last remote is
300 ft (90 m).
• Green or bare copper wire in wall box to Green terminal screw.
• Load wall box wire identified (tagged) when removing old switch to
terminal screw marked "BK".
• First Traveler wall box wire (note color as above) to terminal screw
marked "RD". This traveler from the remote must go to the terminal
screw on the dimmer marked "RD" or Red dimmer lead.
• Second Traveler wall box wire (note color as above) to terminal
screw marked "YL/RD". This traveler from the remote must go to
the terminal screw on the dimmer marked "YL/RD" or Yellow/Red
dimmer lead.
• Remote terminal screw marked "WH" should have White insulation
label affixed.
NOTE: If insulating label is not affixed to terminal screw marked
"WH", use electrical tape to cover.
• Proceed to Step 6.
Step 4c
Connect wires per WIRING DIAGRAM as follows:
NOTE: "BK" and "RD" terminals on coordinating remote are
unused. Tighten both screws.
NOTE: Maximum wire length from control to last remote is
300 ft (90 m).
• Green or bare copper wire in wall box to Green terminal screw.
• Load wall box wire identified (tagged) when removing old switch
to First Traveler (note color as above).
• Second Traveler wall box wire (note color as above) to terminal screw marked "YL/RD". This traveler from the remote must go to
the terminal screw marked "YL/RD" or Yellow/Red control lead.
• Remove White insulating label from terminal screw marked
"WH".
• Line Neutral wall box wire to terminal screw marked "WH".
• Proceed to Step 6.
NOTE: Incandescent and Magnetic Low Voltage
Connect wires per WIRING DIAGRAM as follows:
installations only.
• Green or bare copper wire in wall box to Green terminal screw or
NOTE: Screw terminal dimmer depicted.
Green control lead.
Dimmer
Matching Remote
Matching Remote
• Load wall box wire identified
(3-Way Wall box from Step 2)
(4-Way Wall box from Step 2) (3-Way Wall box from Step 2)
(tagged) when removing old switch
Terminal
Terminal
Additional
Screw marked
Screw marked
Additional
Neutral Wire
to terminal screw marked "RD" or
White (Wh)
White (Wh)
Neutral Wire
Red control lead.
4
2
3
Terminal
• First Traveler Line Hot to terminal
1
Terminal
1
Screw marked
Screw marked
2
Black (Bk)
screw marked "BK" or Black
Black (Bk)
5
4
3
control lead.
3
Terminal
4
Terminal
Screw marked
1
2
Screw marked
• Remove Red insulating label from Yellow/Red
5
Yellow/Red
(YL/RD)
5
6
(YL/RD)
terminal screw marked "YL/RD" or
Yellow/Red control lead.
• Second Traveler wall box wire
(note color as above) to terminal
screw marked "YL/RD" or Yellow/Red control lead. This traveler
from the control must go to the terminal screw on the remote
Matching Remote Matching Remote
Dimmer
(w/LEDs)
(w/LEDs)
marked "YL/RD".
• Line neutral wall box wire to terminal screw marked "WH" or
hot (Black)
Bk
Wh
Wh
Bk
White control lead.
Bk
Green
Green
Green
• Proceed to Step 6.
Black
Ground
Ground
Ground
WIRING COORDINATING REMOTE:
Wiring Dimmer (wall box with Load connection):
Connect wires per WIRING DIAGRAM as follows:
• Green or bare copper wire in wall box to Green terminal screw or
Green dimmer lead.
• Load wall box wire identified (tagged) when removing old switch to dimmer terminal screw marked “RD” or the Red dimmer lead.
• First Traveler Line Hot to dimmer terminal screw marked “BK” or the
Black dimmer lead.
• Remove Red insulating label from terminal screw marked “YL/RD”
or Yellow/Red dimmer lead.
• Second Traveler wall box wire (note color as above) to dimmer terminal screw marked “YL/RD” or the Yellow/Red dimmer lead.
This traveler from the dimmer must go to the terminal screw on the
remote marked “YL/RD”.
• Proceed to Step 6.
Connect wires per WIRING DIAGRAM as follows:
• Green or bare copper wire in wall box to Green terminal screw.
• Line Hot (common) wall box wire identified (tagged) when removing
old switch and First Traveler to terminal screw marked "BK" or Black
dimmer lead.
• Second Traveler wall box wire from control to remote terminal screw
marked "YL/RD" (note wire color). This traveler from the remote
must go to terminal screw marked "YL/RD" or Yellow/Red control
lead.
• Line Neutral wall box to remote terminal screw marked "WH".
Step 4d cont’d
WIRING COORDINATING REMOTE:
Wiring Dimmer (wall box with Load connection):
Green
Ground
Green
Ground
Cut
(if necessary)
hot (Black)
Bk
Green
Ground
WIRING DIMMER:
1
Terminal
Screw marked
Yellow/Red
(YL/RD)
Bk
Wh
Black
Neutral (White)
Dimmer
2
Bk
Terminal
Screw marked
Black (Bk)
5
Terminal
Screw marked
Red (RD)
Strip Gage (measure bare wire here or
use gage on back of the dimmer)
• Make sure that the ends of the wires from the wall box are straight
(cut if necessary).
• Remove insulation from each wire in the wall box as shown.
RD
YL/RD
5
Coordinating Remote (no LEDs)
Line up tabs and
press in sides one at
a time to attach
2
3
RD
YL/RD
Wiring Matching Remote (wall box with Line Hot
connection):
1
3
Terminal
Screw marked
Yellow/Red
(YL/RD)
5/8"
(1.6 cm)
Bk
1
NOTE: The control must be installed in a wall box that has a Load
connection. The matching remote must be installed in a wall box with
a Line Hot connection and a Neutral connection. A Neutral wire to the
matching remote needs to be added as shown.
If you are unsure about any part of these instructions, consult a
qualified electrician.
NOTE: Maximum wire length from control to all installed remotes
cannot exceed 300 ft (90 m).
Connect wires per WIRING DIAGRAM as follows:
NOTE: The control must be installed in a wall box that has a Line Hot
Connection.
NOTE: Maximum wire length from dimmer to all installed remotes
cannot exceed 300 ft (90 m).
• Green or bare copper wire in wall box to Green terminal screw or
Green control lead.
• Line Hot (common) wall box wire identified (tagged) when removing
old switch to terminal screw marked "BK" or Black control lead.
• First Traveler wall box wire to terminal screw marked "RD" or Red
control lead (note wire color).
• Remove Red insulating label from terminal screw marked "YL/RD"
or Yellow/Red control lead.
• Second Traveler wall box wire to terminal screw marked "YL/RD"
or Yellow/Red control lead (note wire color). This traveler from
the control must go to the terminal screw on the remote marked
"YL/RD".
• Line Neutral wall box wire to terminal screw marked "WH" or White
control lead.
Connect wires per WIRING DIAGRAM as follows:
• Green or bare copper wire in wall box to Green terminal screw.
• First Traveler and Third Traveler wall box wire from dimmer in
the 3-way box to remote terminal screw marked "BK" in the
4-way box, and to the terminal screw marked "BK" of the
remaining remote in the 3-way box.
• Second Traveler (tagged) and Fourth Traveler (tagged) wall box
wire from dimmer in the 3-way box to remote terminal screw
marked "YL/RD" in the 4-way box, and to the terminal screw
marked "YL/RD" of the remaining remote in the 3-way box (note
wire colors). This traveler from the remotes must go to the
terminal screw on the dimmer marked "YL/RD" or the Yellow/Red
dimmer lead.
• Line Neutral wall box wire to remote terminal screw marked
"WH".
Wiring MATCHING REMOTE (3-Way wall box with Line
Hot connection):
Connect wires per WIRING DIAGRAM as follows:
• Green or bare copper wire in wall box to Green terminal screw.
• Line Hot (common) wall box wire identified (tagged) when
removing old switch and First Traveler dimmer terminal screw
marked "BK" or the Black dimmer lead.
• Second Traveler wall box wire from dimmer to remote terminal
screw marked "YL/RD" (note wire color as above). This traveler
from the remote must go to the terminal screw on the dimmer
marked "YL/RD" or the Yellow/Red dimmer lead.
• Line Neutral wall box wire to remote terminal screw marked
"WH".
4-Way Wiring with Matching Remote (w/LEDs)
Application:
Step 5a cont’d
NOTE: Electronic Low Voltage, Mark 10™, Quiet Fan Speed and Electronic
Switch installations only.
NOTE: Dimmer is depicted.
Wiring Dimmer (3-Way wall box with Load connection):
Connect wires per WIRING DIAGRAM as follows:
• Green or bare copper wire in wall box to Green terminal screw or Green dimmer
lead.
• Load wall box wire identified (tagged) when removing old switch to dimmer terminal
screw marked "RD" or the Red dimmer lead.
• First Traveler Line Hot to dimmer terminal screw marked "BK" or the Black dimmer
lead.
• Remove Red insulating label from terminal screw marked "YL/RD" or the Yellow/
Red dimmer lead.
• Second Traveler wall box wire (note color as above) to dimmer terminal screw
marked "YL/RD" or the Yellow/Red dimmer lead. This traveler from the dimmer
must go to the terminal screw on the remote marked "YL/RD".
• Proceed to Step 6.
Step 5b
4-Way Wiring with Coordinating Remote (no LEDs)
Application:
Terminal
Screw marked
Black (BK)
Terminal
Screw marked
Yellow/Red
(YL/RD)
BK
RD
YL/RD
WH
NOTE: The control must be installed in a wall box that has a Load connection. The
matching remote must be installed in a wall box with a Line Hot connection and a Neutral
connection. A Neutral wire to the matching remote needs to be added as shown.
If you are unsure about any part of these instructions, consult a qualified electrician.
NOTE: Maximum wire length from control to all installed remotes cannot exceed
300 ft (90 m).
Connect wires per WIRING DIAGRAM as follows:
NOTE: The control must be installed in a wall box that has a Line Hot connection.
NOTE: Maximum wire length from control to all installed remotes cannot exceed 300 ft
(90 m).
• Green or bare copper wire in wall box to Green terminal screw or Green control lead.
• Line Hot (common) wall box wire identified (tagged) when removing old switch to
terminal screw marked "BK" or Black control lead.
• First Traveler wall box wire to terminal screw marked "RD" or Red control lead (note
wire color as above).
• Remove Red insulating label from terminal screw marked "YL/RD" or Yellow/Red
control lead.
• Second Traveler wall box wire to terminal screw marked "YL/RD" or Yellow/Red
control lead (note wire color as above). This traveler from the control must go to the
terminal screw on the remote marked "YL/RD".
• Line Neutral wall box wire to terminal screw marked "WH" or White control lead.
Wiring Matching Remote (4-Way wall box with Line Hot connection):
WIRING COORDINATING REMOTE (3-Way box):
Green
Ground
Green
Ground
Black
Yellow/Red
Red
YL/RD
YL/RD
Line
120VAC, 60Hz
Terminal
Screw marked
Yellow/Red
(YL/RD)
Bk
YL/RD
1
Load
3
4
4
1
RD
YL/RD
5
Load
Wh
RD
2
3
5
4
2
6
YL/RD
Coordinating Remote
(no LEDs)
Bk
not used
Wh
Green
Ground
RD
1
RD
5
Terminal
Screw marked
Yellow/Red
(YL/RD)
Coordinating Remote
(no LEDs)
not used
Neutral (White)
Bk
3
Terminal
Screw marked
Red (RD)
Black
White
Bk
2
YL/RD
RD
Dimmer
hot (Black)
not used
Bk
Green
Ground
Green
Ground
Bk
YL/RD
RD
YL/RD
Line
120vAC, 60hz
White
Neutral (White)
WIRING COORDINATING REMOTE (4-Way box):
Connect wires per WIRING DIAGRAM as follows:
NOTE: Maximum wire length from dimmer to last remote is 300 ft (90 m).
• Green or bare copper wire in wall box to Green terminal screw.
• First Traveler and Third Traveler wall box wire (note wire colors) to terminal
screw marked "RD". These travelers from the remote in the 4-way box must go to
the terminal screw on the dimmer marked "RD" or Red dimmer lead, and to the
terminal screw marked "RD" of the remaining remote in the 3-way box.
• Second Traveler (tagged) and Fourth Traveler (tagged) wall box wire (note wire
colors) to terminal screw marked "YL/RD". These travelers from the remote in
the 4-way box must go to the terminal screw on the dimmer marked "YL/RD" or
the Yellow/Red dimmer lead, and to the terminal screw marked "YL/RD" of the
remaining remote in the 3-way box.
• Remote terminal screw marked "WH" should have White insulation label affixed.
NOTE: If insulating label is not affixed to terminal screw marked "WH", use
electrical tape to cover. Remote terminal screw marked "BK" is not used. Use
electrical tape to cover.
WIRING DIMMER (3-Way box):
Connect wires per WIRING DIAGRAM as follows:
NOTE: When using the coordinating remote without LEDs, the dimmer can be
installed on either the Line or Load side of the 3-way circuit.
NOTE: Maximum wire length from dimmer to all installed remotes cannot exceed
300 ft (90 m).
• Green or bare copper wire in wall box to Green terminal screw or Green dimmer
lead.
• Line Hot (common) wall box wire identified (tagged) when removing old switch to
dimmer terminal screw marked "BK" or Black dimmer lead.
• First Traveler wall box wire to dimmer terminal screw marked "RD" or Red dimmer
lead (note wire color as above). This traveler from the dimmer must go to the
terminal screw on the remote marked "RD".
• Remove Red insulating label from terminal screw marked "YL/RD" or Yellow/Red
dimmer lead.
• Second Traveler wall box wire to dimmer terminal screw marked "YL/RD" or Yellow/
Red dimmer lead (note wire color as above). This traveler from the dimmer must
go to the terminal screw on the remote marked "YL/RD".
WIRING COORDINATING REMOTE (3-Way box):
Connect wires per WIRING DIAGRAM as follows:
NOTE: Maximum wire length from dimmer to last remote is 300 ft (90 m).
• Green or bare copper wire in wall box to Green terminal screw.
• Load wall box wire identified (tagged) when removing old switch to terminal screw
marked "BK".
• First Traveler wall box wire (note color as above) to terminal screw marked "RD".
This traveler from the remote must go to the terminal screw on the dimmer marked
"RD" or the Red dimmer lead.
• Second Traveler wall box wire (note color as above) to terminal screw marked
"YL/RD". This traveler from the remote must go to the terminal screw on the
dimmer marked "YL/RD" or the Yellow/Red dimmer lead.
• Remote terminal screw marked "WH" should have White insulation label affixed.
NOTE: If insulating label is not affixed to terminal screw marked "WH", use
electrical tape to cover.
• Proceed to Step 6.
Connect wires per WIRING DIAGRAM as follows:
• Green or bare copper wire in wall box to Green terminal screw.
• First Traveler and Third Traveler wall box wire to remote terminal screw marked "BK"
in 4-way box, and to terminal screw marked "BK" of the remaining remote in 3-way
box.
• Second Traveler (tagged) and Fourth Traveler (tagged) wall box wire from control in
3-way box to remote terminal screw marked "YL/RD" in 4-way box and to terminal
screw marked "YL/RD" of the remaining remote in 3-way box (note wire colors). This
traveler from the remotes must go to the terminal screw marked "YL/RD" or
Yellow/Red control lead.
• Line Neutral wall box wire to remote terminal screw marked "WH".
Wiring MATCHING REMOTE (3-Way wall box with Line Hot connection):
Connect wires per WIRING DIAGRAM as follows:
• Green or bare copper wire in wall box to Green terminal screw.
• Line Hot (common) wall box wire identified (tagged) when removing old switch and
First Traveler wall box wire to control terminal screw marked "BK" or Black dimmer
lead.
• Second Traveler wall box wire from control to remote terminal screw marked "YL/RD"
(note wire color as above). This traveler from the remote must go to the terminal
screw marked "YL/RD" or Yellow/Red dimmer lead.
• Line Neutral wall box wire to remote terminal screw marked "WH".
Connect wires per WIRING DIAGRAM as follows:
NOTE: "BK" and "RD" terminals on coordinating remote are unused. Tighten both
screws.
NOTE: Maximum wire length from control to last remote is 300 ft (90 m).
• Green or bare copper wire in wall box to Green terminal screw.
• Load wall box wire identified (tagged) when removing old switch to First Traveler (note
color as above).
• Second Traveler wall box wire (note color as above) to terminal screw marked
"YL/RD". This traveler from the remote must go to the terminal screw marked "YL/RD"
or Yellow/Red control lead.
• Remove White insulating label from terminal screw marked "WH".
• Line Neutral wall box wire to terminal screw marked "WH".
• Proceed to Step 6.
Step 6 Testing your Remote prior to completely
mounting in wall box:
• Position all wires to provide room in
outlet wall box for device.
• Ensure that the word "TOP" is facing up
on the device strap.
• Partially screw in mounting screws in
wall box mounting hole.
Wiring CONTROL (3-Way wall box with Load connection):
Connect wires per WIRING DIAGRAM as follows:
• Green or bare copper wire in wall box to Green terminal screw or Green dimmer lead.
• Load wall box wire identified (tagged) when removing old switch to terminal screw
marked "RD" or Red control lead.
• First Traveler Line Hot to terminal screw marked "BK" or Black control lead.
• Remove Red insulating label from terminal screw marked "YL/RD" or Yellow/Red
control lead.
• Second Traveler wall box wire (note color as above) to terminal screw marked
"YL/RD" or Yellow/Red control lead. This traveler from the control must go to the
terminal screw on the remote marked "YL/RD".
• Line Neutral wall box wire to terminal screw marked "WH" or White control lead.
• Proceed to Step 6.
Step 5d
Coordinating Remote
(4-Way Box from Step 2)
Control
(3-Way Wall Box from Step 2)
Terminal
Screw marked
White (WH)
Terminal
Screw marked
Yellow/Red
(YL/RD)
BK
3
1
Terminal
Screw marked
Black (BK)
2
Terminal
Screw marked
Yellow/Red
(YL/RD)
4
YL/RD
RD
5
BK
1
2
2
1
NOTE: Dress wires with a bend as shown in diagram in order to relieve stress when
mounting device.
• Restore power at circuit breaker or fuse.
• See applicable operation section to ensure dimmer or switch is functioning properly.
• If lights do not turn ON, refer to the TROUBLESHOOTING section.
Green
5
RD
3
6
Red
Yellow/Red
4
5
Coordinating Remote
(no LEDs)
WH
not used
Coordinating Remote
(no LEDs)
WH
Green
Ground
Black
RD
not used
Load
BK
YL/RD
BK
not used
Green
Ground
RD
not used
YL/RD
Locator
Light
VP0SR Switch Remote Operation (Device may be unlighted):
The lighting can be switched from either the dimmer or the remote location.
Push Pad (Default settings)
Turn ON from OFF position:
Tap – Lights turn ON to preset level.
Turn OFF from ON position:
Tap – Lights turn OFF.
In the event of power outage or
interruption the lights will reset to the last
level when power is restored.
Push Pad
Locator
Light
VP00R-1L ADVANCED PROGRAMMING FEATURES
FOR USE WITH VIZIA RF +™ ONLY
Definition of A Modes
A)LED Options: Sets single LED (default) or LED Bar to display the load status.
Program Mode A
To enter Program Mode A:
Press and hold the Push Pad and then the right half of the DIM/BRIGHT Bar (^) for 5
seconds until all LEDs blink.
Upon releasing the Push Pad Locator LED will blink once per second to indicate
Program Mode A, LED Options. To change the LED Options settings, release
the Push Pad. This setting will automatically be saved and the device will exit
Programming Mode.
LED Options
LED Brightness/Fan Speed Display
Default
Single LED
First toggle
LED Bar
Lights Flickering
- Lamp has a bad connection.
- Wires not secured firmly under terminal screws of dimmer and/or remote.
Light does not turn ON and Locator LED does not turn ON
- Circuit breaker or fuse has tripped.
- Lamp is burned out.
- Lamp Neutral connection is not wired.
Intermittent dimmer operation
- Minimum load is under 40W.
Remote does not operate lights
- Ensure that total wire length does not exceed 300 ft (90 m).
- Ensure that only Coordinating Remotes are used with Vizia rf +™ devices
White
3
4
YL/RD
DIM/BRIGHT
Bar
Push Pad (Default settings)
Turn ON from OFF position:
Tap – Lights turn ON to preset level.
Press and Hold – Lights turn ON to full bright.
Turn OFF from ON position:
Tap – Lights turn OFF.
DIM/BRIGHT Bar
BRIGHTEN:
Press right half of DIM/BRIGHT Bar – Lights brighten to
desired level.
DIM:
Press left half of DIM/BRIGHT Bar – Lights dim to
desired level.
If you continue to hold, the lights will DIM to minimum
level and then turn OFF.
In the event of power outage or interruption the lights will
reset to the last level when power is restored.
For additional information, contact Leviton’s Techline at
1-800-824-3005 or visit Leviton’s website at www.leviton.com
Black
Terminal
Screw marked
Black (BK)
Push Pad
•
•
•
•
NOTE: Electronic Low Voltage, Mark 10™, Quiet Fan Speed and
Electronic Switch installations only. NOTE: Dimmer is depicted.
Terminal
Screw marked
White (WH)
LED
Brightness
Display
TROUBLESHOOTING
4-Way Wiring with Coordinating Remote (no LEDs) for Controls
with Neutral Connection Application:
Coordinating Remote
(3-Way Wall box from Step 2)
VP00R Dimmer Remote Operation (Device may be unlighted):
NOTE: The lights will turn ON at brightness set on dimmer’s DIM/BRIGHT bar. The
lighting can be switched from either the dimmer or the remote location.
WIRING CONTROL (3-Way box):
Black
White
BK
WH
BK
CLEANING: Clean with a damp cloth. DO NOT use chemical cleaners.
RD
YL/RD
Terminal
Screw marked
Red (RD)
Terminal
Screw marked
Black (Bk)
WIRING COORDINATING REMOTE (4-Way box):
BK
Green
Ground
Coordinating Remote
Dimmer
(4-Way Box from Step 2) (3-Way Wall Box from Step 2)
OPERATION
Step 5d cont’d
Connect wires per WIRING DIAGRAM as follows:
NOTE: "BK" and "RD" terminals on coordinating remote are unused. Tighten both
screws.
Matching Remote
Matching Remote
Control
(3-Way Wall box from Step 2)
(4-Way Wall box from Step 2) (3-Way Wall Box from Step 2) NOTE: Maximum wire length from dimmer to last remote is 300 ft (90 m).
Terminal
Terminal
Green
Additional
Screw marked
Screw marked
Additional
• Green or bare copper wire in wall box to Green terminal screw.
Neutral Wire
White (WH)
White (WH)
Neutral Wire
Black
• Connect First Traveler wall box wire to Third Traveler wall box wire (note wire colors)
4
2
3
to terminal screw marked "RD" of remote in 4-way box, and to terminal screw marked
1
Terminal
1
2
Screw marked
White
Black (BK)
"RD" of the remaining remote in 3-way box.
5
4
3
4
• Connect Second Traveler and Fourth Traveler wall box wire (note wire colors) to
Terminal
3
Red
2
1
Screw marked
5
Yellow/Red
terminal screw marked "YL/RD" of remote in 4-way box, and to terminal screw marked
6
(YL/RD)
"YL/RD" of the remaining remote in 3-way box.
5
Yellow/Red
This traveler from the remotes must go to the terminal screw marked "YL/RD" or
Yellow/Red control lead.
• Remove White insulating label from terminal screw marked "WH".
Matching Remote Matching Remote
Control
• Line Neutral wall box wire to terminal screw marked "WH".
(w/LEDs)
(w/LEDs)
Hot (Black)
NOTE: Incandescent and Magnetic Low Voltage installations only.
NOTE: Screw terminal dimmer depicted.
Coordinating Remote
(3-Way Wall box from Step 2)
4-Way Wiring with Matching Remote (w/LEDs) for Controls
with Neutral Connection Application:
Step 5c
Step 7 Dimmer Remote Mounting:
Control
White
Turn off power at circuit breaker or fuse.
Hot (Black)
Black
Green
Ground
Red
YL/RD
Line
120VAC, 60Hz
Installation may now be completed by tightening
mounting screws into wall box. Attach wallplate.
White
Neutral (White)
Step 8 Restore Power:
Covered by one or more US & Foreign Patents and patents pending
Copyright© 2007 Leviton Manufacturing Co., Inc.
All Rights Including Trade Dress Rights Reserved
Eco-10™ (Eco Series) is a trademark and Hi-lume® is a registered trademark of
Lutron Electronics Inc.
FCC COMPLIANCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class B
Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment OFF
and ON, the user is encouraged to try to correct the interference by one or more of the
following measures:
• Reorient or relocate the receiving Antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/tv technician for help.
Restore power at circuit breaker or fuse. Installation is complete.
PK-93461-10-00-2A
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof of purchase
date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in
any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five
years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.