Data Sheet

advertisement
Raintight
NEMA3
RS, RSM and RSS Junction Boxes
Conduit Hub Plates and Gaskets
6F-9
Application:
RS, RSM, RSS junction boxes
are installed in conduit systems
to:
• act as pull box for conductors
• provide openings and space
for making splices and taps in
conductors
• provide for branch conduit
runs
• provide access to conductors
for maintenance and future
system changes
Features:
• Junction box bodies accept
wide range of hub plates
permitting varied hub
arrangements and sizes.
• Stocking a few components
provides for many specific
needs.
• Future system expansion
easily accomplished by
substituting hub plates for
currently installed plates.
• Suitable for use where boxes
with integral hubs cannot satisfy
requirements.
• Suitable for surface mounting
outdoors or indoors in rigid
conduit runs.
Standard Materials:
• Bodies and hub plates Feraloy" iron alloy
• Gaskets - cork
Standard Finishes:
• Feraloy iron alloy electrogalvanized and aluminum
acrylic paint
Junction
Boxest
Conduit Hub Plates t
Approximate Inside
Dimensions
For 8Va x 4 inch Sides
of RS and RSM Boxes
Size
8V4x8V4x4
8V4x4V4x4
4Vix4V6x4
Cat. #
RS1
RSM1
RSS1
Replacement
Cover Gaskets
Size
8Vi x 8'A
8Vix4Vfe
4Vfe x 4Vi
Cat. #
GASK61 '
GASK63
GASK64
Size
!4
%
1
1%
1Vfe
2
2V&
3
One
Two
Three
Hub
Hubs Hubs
Cat. # Cat. # Cat. #
RSP1
RSP11 RSP111
RSP2 RSP22 RSP222
RSP3 RSP33 RSP333
RSP4 RSP44 RSP444
RSP5 HSP55 RSP555
RSP6 RSP66
RSP7
RSP8
Blank
Hub
Plate
Cat.#
RSPO
Certifications and
Compliances:
• UL Standard: 514A
• CSA Standard: C22.2 No. 18
For 41/£ x 4 inch Sides
of RSM and RSS Boxes
One
Two
Hub
Hubs
Size Cat. #
Vi
RSMP1
%
RSMP2
1
RSMP3
RSMP4
1'/4
V/z
RSMP5
2
RSMP6
2'/2
RSMP7
Cat. #
RSMP11
RSMP22
Blank
Hub
Plate
Cat. #
RSMPO
Replacement Hub Plate Gaskets
Size
8Vi>x4
Cat.#
GASK66
Size
4V£x4
t Includes body, top cover with gaskel. 4 gaskete lor side plates, and 20 bolts.
$ Hub plates only. Gaskets rtoi included.
NOTE: For conduit liner ordering information, 38epage6F-29.
Copyright0 2000 Cooper Industries, Inc.
Cat. #
GASK65
Junction Boxes
6F-1
Quick Selector Chart
Quick Selector Chart
Junction
Boxes
NEC/CEC
Hazardous
Area
Compliance
——
Environmental
Capability/Type
Designation
Size Ranget
L, W, D Inside
Raintight/Type 3,
Dust-tight/Type12
4 x 4 x 2 to
Raintight/Type 3,
Watertight/Type 4,
Dust-tight/Type12
4 x 4 x 2 to
Raintight/Type 3,
Watertight/Type 4
4 x 4 x 4 to
WJBF
Raintight/Type 3,
Watertight/Type 4
RS, RSM,
RSS
GU, CUE, Cl. I, Div. 1 &2,
GUB
Groups B,C,D; Cl.
WAB
WCB
WJB
II, Div. 1, Groups
E,F,G;CI. II, Div.
2, Groups F,G;
Cl. Ill
EJB
Cl. I, Div. 1 &2,
Groups B,C,D; Cl.
II, Div. 1, Groups
E,F,G; Cl. II, Div.
2, Groups F,G;
Cl. Ill
GUA
Cl. I, Div. 1 &2,
Groups C,D; Cl.
II, Div. 1, Groups
E,F,G; Cl. II, Div.
2, Groups F,G;
Cl. Ill
GUP
Cl. I, Div. 1 &2,
Groups C,D; Cl.
II, Div. 1, Groups
E,F,G; Cl. II, Div.
2, Groups F,G;
Max.
Conduit
Opening
Size
Mtg.
Type of
Conduit
Opening
Cover
"Type
5
Surface
Drilled and
tapped, slip
holes
Unflanged
2
5
Surface
Drilled and
tapped, slip
holes
Overlapping
3
6
Surface
Drilled and
tapped, slip
holes
Flanged
4
4 x 4 x 4 to
24 x 24 x 1 2
6
Flush
Drilled and
tapped, slip
holes
External
flanged
recessed
sidewalk
5
Raintight/Type 3
41/2 x 41/2 x 4 to
81/2 x 81/2 x 4
3
Surface
Detachable
hub plates
Flanged
9
Raintight/Type 3
Watertight/Type 4*
Hazardous/Types
7,9
4 5 /16X4 5 /16X4 1 /8tO
4
Surface
Drilled and
tapped
Threaded,
glass window
and domed
covers
available
10
Raintight/Type 3,
Watertight/Type 4
(Style C only)
Hazardous/Types
7,9
6 x 4 x 4 to
60 x 22 x 1 2*
6
Surface
Drilled and
tapped
Ground joint
16
Raintight/Type 3,
Watertight/Type 4
(S302 Suffix)
Hazardous/Types
3%x3 3 /sx1%
1
Surface
Union hubs
Threaded
24
Raintight/Type 3,
Watertight/Type 4
(S302 Suffix)
Hazardous/Types
7,9
3% x 3% x 21A
%
Surface
Drilled and
tapped cast
hubs
Threaded
£.\J
Raintight/Type 3,
Watertight/Type 4
(S302 Suffix)
Hazardous/Types
7,9
*
4% Diameter, 8
max depth
%
Surface
Drilled and
tapped
Threaded
26
Raintight/Type 3
Hazardous/Types
7,9
51/2 x 51/2 x 4 to
6% x 6% x 5
1
Flush
Drilled and
tapped
Threaded
27
12x12x8
12x12x8
24x24x12
17x16%x173/s
«
7,9
Cl. I, Div. 1 &2,
Group D;CI. II,
Div. 1, Groups
E,F,G;CI. II, Div.
2, Groups F,G,;
Cl. Ill
EGJ
Cl. I, Div. 1 &2,
Group D; Cl. II,
Div. 1, Groups
E,F,G;CI. II, Div.
2, Groups F,G;
Cl. Ill
t Length and width are inside dimensions. Depth is inside dimension without cover.
$ All except GUB01110 and GUB15151.
* EJB602212 is suitable for Class I, Div. 1, Groups C and D.
Copyright" 2000 Cooper Industries, Inc.
25
i
Cl. Ill
EJH
1
1
Page 1
No. I