Occupancy Sensor Lighting Controls Leviton’s Wall Switch and Ceiling Mounted Occupancy Sensors use passive infrared or ultrasonic sensing technology to provide costeffective lighting control. Leviton Occupancy Sensors are capable of monitoring conference rooms, classrooms, stairwells, stock rooms, lounges, rest rooms, and outdoor areas. The Passive Infrared (PIR) units respond to change in the infrared background by turning lights ON when people enter a space being monitored, and OFF when the space is unoccupied. The ultrasonic units transmit ultrasound and monitor for changes in the signal’s return time to detect occupancy, turning lights ON when movement is detected, and OFF when the space is unoccupied. By analyzing traffic flow, Leviton Occupancy Sensors can be installed to generate significant lighting cost savings combined with energy efficiency. OCCUPANCY SENSOR LIGHTING CONTROLS Overview ____________________________P1 Decora Wall Switch Infrared Occupancy Sensors ___________________P2 Decora Dual-Relay Wall Switch Infrared Occupancy Sensor ____________________P2 Centura™ Fluorescent Energy Management System ________P3, P4 Self-Contained Infrared Ceiling Mount Occupancy Sensor ____________________P5 Multi-Tech Ceiling Mount Occupancy Sensor ____________________P6 Ultrasonic Ceiling Mount Occupancy Sensor ____________________P7 Infrared Ceiling Mount Occupancy Sensor ____________________P8 Multi-Tech Wall Mount Occupancy Sensor ____________________P9 Infrared Wide-View Wall Mount Occupancy Sensor ___________________P10 Infrared High-Bay Wall Mount Occupancy Sensor ___________________P10 Power Packs for Occupancy Sensors ___P11 Infrared Outdoor Motion Sensors _______P12 S E C T I O N P Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Commercial Grade Occupancy Sensor Lighting Controls Leviton provides a variety of spacemonitoring Occupancy Sensor Lighting Controls for virtually any room, space, facility, home or office. Wall or ceiling, passive infrared or ultrasonic, end users will benefit from Leviton's Occupancy Sensors as a direct result of their energy efficiency and obvious cost-effectiveness. Passive Infrared (PIR) detection technolgy to monitor room for occupancy Fresnel lenses for “small motion” detection to monitor room movement Sensor automatically sends signal to switch lights on and keep them on when room is occupied and activity detected Features and Benefits ■ 180° field of view, covers approximately 2100 square feet ■ Selectable base time-delay interval from 30 seconds to 20 minutes ■ Self-adjusting delayed off time interval compensates for real time occupancy patterns, preventing unnecessary on/off switching ■ Can be used with incandescent or fluorescent lighting ■ Motion-activated; infrared sensing technology turns lights ON when room is occupied and OFF when unoccupied ■ Replaces standard switches in existing wallboxes ■ Ambient light override keeps lights off when there’s plenty of sunlight ■ Push-button manual override allows controls to be used like standard ON/OFF switches; manual-ON/Auto-OFF mode ■ “Walk-Through” feature shuts off lights after 21/2 minutes rather than an extended period ■ Compatible with Decora designer-styled devices ■ Backed by a Limited Five-Year Warranty 180° field of view, 2,100 square feet of coverage Adjustable delayed offtime (30 seconds 20 min- LED indicator light flashes when sensor detects motion Ambient light override prevents the sensor from switching lights on when there is ample natural sunlight Cat. No. ODS15-IDW Versatile Occupancy Sensor Lighting Controls for Cost-Effective Energy Savings Multi-Technology Ceiling-Mount Occupancy Sensor Multi-Technology Wall-Mount Occupancy Sensor Infrared High-Bay Wall-Mount Occupancy Sensor Combines infrared and ultrasonic technology for highly accurate monitoring. 360°, 2000 sq. ft coverages. Combines infrared and ultrasonic technology for highly accurate monitoring. 110°, 1200 sq. ft coverage. Ideal for warehouse aisles, hallways, stairways and other long, narrow spaces. Cat. No. ODC20-M0W Cat. No. ODW12-M0W Cat. No. ODWHB-I0W Self-Contained Ceiling Mount PIR Occupancy Sensor Contains sensor and switching relay; 360° field of view; adjustable delayed off time of 20 seconds to 15 minutes. Cat. No. ODC0S-I1W Dual-Relay Decora Wall Switch Infrared Occupancy Sensor Controls two separate lighting loads from a single unit. Features self-adjusting technology and choice of Classroom or Conference Room modes for maximum performance. Outdoor Motion Sensor Ideal for commercial/industrial settings, with temperature compensation to ensure performance in all weather conditions. Cat. No. PS200-10W Cat. No. ODS0D-IDW P1 To learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com ....Building a Connected World Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Occupancy Sensor Lighting Controls Commercial Grade Decora ® Wall Switch Infrared Occupancy Sensor (Incandescent or Fluorescent) DESCRIPTION CAT. NO. RATING COLOR Decora Wall Switch PIR Occupancy Sensor with Self-Adaptive Technology ODS15-ID (formerly 6768) I, W, G, A Decora Wall Switch PIR Occupancy Sensor ODS10-ID (formerly 16775) Fluorescent: 1800VA @ 120V, 4000VA @ 277V. Incandescent: 1800W @ 120V. Motor: 1/4 HP @ 120V Incandescent: 800W @ 120V, Fluorescent: 1200VA @ 120V, 2700VA @ 277V. For 60 Hz AC only. Motor: 1/4 HP @ 120V I, W, G, A Dual-Relay Decora ® Wall Switch Infrared Occupancy Sensor DESCRIPTION CAT. NO. PHOTOCELL CONTROL OPTIONS PER RELAY RATING COLOR Dual-Relay Decora Wall Switch PIR Occupancy Sensor with Self-Adaptive Technology ODS0D-ID (formerly 6772) Default Setting: Conference Room Mode Both Primary.and Secondary Relays respond to Ambient Light Override. Alternate Setting: Classroom Mode Primary Relay only responds to Ambient Light Override. Primary Relay: Fluorescent: 1200VA @ 120V, 2700VA @ 277V Incandescent: 800W @ 120V. Secondary Relay: Fluorescent: 800VA @ 120V, 1200VA 277V. Incandescent: 800W @ 120V I, W, G, A ODS15-IDW in 80301-W Decora® Wall Switch Infrared Occupancy Sensor DESCRIPTION CAT. NO. RATING COLOR Decora Wall Switch PIR Occupancy Sensor, Single-Pole & 3-Way, 180° field of view PR180-1L Incandescent: 500W, Fluorescent: 400VA Rapid Start Magnetic only @ 120V AC, Motor: 1⁄8 HP @ 120V AC I, W, A ODS0D-IDW in 80301-W Residential Grade Decora® Wall Switch Infrared Occupancy Sensor DESCRIPTION CAT. NO. RATING COLOR Decora Wall Switch PIR Occupancy Sensor, Single-Pole, 150° field of view PR150-1L Incandescent: 500W, Fluorescent: 400VA Rapid Start Magnetic only @ 120V AC, Motor: 1⁄8 HP @ 120V AC I, W, A All devices are UL Listed and CSA Certified. SPECIFICATIONS & FEATURES 1.75 (44.4 mm) 1.30 (33.0 mm) 0.49 (12.6 mm) ON OFF AUTO BOTTOM Cat. No. ODS15-ID 2.60 (66.1 mm) 4.06 (103.2 mm) 2.61 (66.3 mm) 1.35 (34.3 mm) Decora Wall Switch PIR Occupancy Sensor (ODS15-ID) • For use in small offices, conference rooms, class rooms, stock rooms, lounges, restrooms, warehouses & commercial areas • Exclusive automatic “Walk-Through” sensing increases energy savings by shutting lights within 2 1⁄2 minutes after momentary occupancy • Self-adjusting delayed OFF-time interval compensates for real-time occupancy patterns, preventing unnecessary ON/OFF switching • 180° field of view, 2100 sq. ft. of coverage Dual-Relay Decora Wall Switch PIR Occupancy Sensor (ODS0D-ID) • Ideal for class rooms and conference rooms • Exclusive automatic “Walk-Through” sensing • Provides automatic switching for 2 separate banks of fluorescent, incandescent, or low-voltage lighting from a single unit • Self-adjusting delayed OFF-time interval compensates for real-time occupancy patterns, preventing unnecessary ON/OFF switching • 180° field of view, 2100 sq. ft. of coverage • Ambient light override prevents these devices from switching lights ON when there is ample natural sunlight • Push-button manual override is used to turn lights ON at any time, regardless of the override setting Wall Switch PIR Occupancy Sensor (ODS10-ID) • For use in enclosed offices, storage rooms, copier rooms & closets • One unit can be used for 120V or 277VAC 60Hz incandescent, lowvoltage and fluorescent lighting with either magnetic or electronic ballasts, and motor loads. • 180° field of view • Fits in standard wallbox; gangable • Delayed-off time settings: 10, 20 and 30 minutes with 30-second test mode • Elegant Decora styling; uses Decora wallplate TESTING & CODE COMPLIANCE • • • • • UL Listed (File #E-118904) Cat. No. ODS0D-ID is CUL/US Certified CSA Certified (File #LR-91148M) NOM Certified (#057) Conforms to California Title 24 Energy Code • Backed by a Limited Five-Year Warranty COLOR Colors available as listed, add suffix to catalog number as follows: Ivory (-I), White (-W), Gray (-G), Almond (-A). MATERIAL CHARACTERISTICS Operating Temperature: 0°C to 50°C Storage Temperature: -10°C to 85°C Relative Humidity: 20% to 90% noncondensing For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 ....Building a Connected World P2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Commercial Grade Fluorescent Energy Management System Centura™ Fluorescent Energy Management System Centura combines the technology of "daylight harvesting " with a host of innovative energy-efficient modular lighting controls, including dimmers, timers, occupancy sensors and photo-sensors that dim or turn off fluorescent lighting when a space is not being used. Centura incorporates the ability to interface with any Leviton occupancy sensor to provide even greater energy savings. When single or multiple occupancy sensors are installed, programmed interior lighting is automatically turned OFF when the room is vacant and back ON to the programmed level when occupancy is detected. The use of movement sensors means energy savings up to a proven 50%. Leviton Occupancy Sensors Compatible with Centura System DESCRIPTION CAT. NO. COVERAGE PAGE NO. Multi-Tech Ceiling Sensor ODC05-M0W 180°, 500 sq. ft P6 Multi-Tech Ceiling Sensor ODC10-M0W 180°, 1000 sq. ft P6 Multi-Tech Ceiling Sensor ODC20-M0W 360°, 2000 sq. ft P6 Ultrasonic Ceiling Sensor ODC05-U0W 180°, 500 sq. ft P7 Ultrasonic Ceiling Sensor ODC10-U0W 180°, 1000 sq. ft P7 Ultrasonic Ceiling Sensor ODC20-U0W 360°, 2000 sq. ft P7 PIR Ceiling Sensor ODC04-I0W 360°, 450 sq. ft P8 Multi-Tech Wall Sensor ODW12-M0W 110°, 1200 sq. ft P9 PIR High-Bay Sensor ODWHB-I0W 120 ft, 14 ft wide @ 30 ft height P10 PIR Wide-View Sensor ODWWV-I0W 110°, 2500 sq. ft P10 Note: The Leviton Occupancy Sensors listed can be powered by the Centura Dimming Power Pack–Use of a separate Occupancy Sensor Power Pack is not required. Agency approvals for all Centura components are UL, CSA, FCC, and California Title 24 (where applicable). CONTROLLER Cat. No. CN221 OCCUPANCY SENSOR PHOTOCELL Cat. No. ODC0P Phase Dimming Power Pack Cat. No. CN100 POWER (+24V) GROUND OCCUPANY CAN_H CAN_L PHOTCELL Neutral DIM RETURN HVAC NO HVAC NC HVAC COMM. HVAC Interface 0–10V DC Ballast CENTURA™ ENERGY MANAGEMENT SYSTEM ESSENTIAL COMPONENTS For more information on the Centura™ Fluorescent Energy Management System, visit Leviton’s website at www.leviton.com/centura P3 For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 ....Building a Connected World Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Fluorescent Energy Management System Commercial Grade Centura™ Fluorescent Energy Management System Leviton’s new Centura™, a modular lighting control system for dimming fluorescent ballasts (Advance Mark VII™, OSRAM Sylvania Quicktronic® Helios™ and Energy Savings SuperDim™), brings increased energy savings to commercial spaces. Using a technique known as “daylight harvesting”, Centura factors in the available daylight for the precise control of fluorescent light levels to achieve optimum comfort and energy efficiency. Centura™ Fluorescent Energy Management System DESCRIPTION CAT. NO. RATING Centura Dimming Power Pack*—ON/OFF and DIM/BRIGHT control of 0-10VDC dimming fluorescent ballasts. Responds to Wall Controller, Occupancy Sensor and Photocell input and provides +24 VDC power supply for these devices. Programmed via Wall Controller or via Leviton Personal Dimmer software from a PC. Secondary relay sends control signals to HVAC system. LED's indicate operation mode. CN100-0D0 2400VA @ 120V AC 60Hz, 5500VA Gray Metallic @ 277V AC 60Hz. For use with 0-10VDC Advance Mark VII™, OSRAM Sylvania Quicktronic® Helios™, Energy Savings SuperDim™ and comparable ballasts only Centura Dimming Controller with Infrared Receiver*— Decora-style 5-button unit for ON/OFF, DIM/BRIGHT and MAX override. Built-in IR receiver for use with Centura NE200-00E Hand-Held Remote. Programs energy management functions. CN200-00C No load rating, for use with Centura Dimming Power Pack only White (Ivory color change kit included) Centura Hand-Held Remote Controller Infrared— Remote provides convenient ON/OFF, DIM/BRIGHT control presets and programming. Designed for use with Centura CN200 Entry Station with Infrared Receiver. NE200-00E No load rating, for use with Centura CN200 Controller only Black Centura Switching Controller*— Decora-style rocker for ON/OFF switching CN220-00C No load rating White (Ivory color change kit included) Centura Dimming Controller*—Decora-style rocker for ON/OFF switching with built-in arrow-shaped rocker for DIM/BRIGHT control. LED display indicates selected brightness level. Programs energy management functions— back of wallplate provides instruction label that lines up with LED's to facilitate programming. CN221-00C Centura Photocell*—Detects available light levels for “Daylight Harvesting”. Allows Centura system to maintain a programmed light level by constantly adjusting fluorescent light output to compensate for changes in available daylight. Centura SmartJack*—Allows desktop PC control of Centura Lighting Control System. Includes a cable for connecting the SmartJack to a PC and a mini-CD containing server, administrator and user software. For the latest software upgrades, check Leviton’s website COLOR No load rating, for use with Centura Dimming Power Pack only White (Ivory color change kit included) ODC0P No load rating, for use with Centura Dimming Power Pack only. 0–70 foot candles White NE100-00C No load rating, for use with Centura Power Pack White (Ivory color change kit included) CN100 CN221 SPECIFICATIONS & FEATURES • Ideal for commercial spaces and individual offices • Reduces eyestrain and fatigue from glare, Increasing comfort and productivity • All functions conveniently accessed through Controllers or via Leviton Personal Dimmer software from a PC • Dimming Power Pack provides lowvoltage power supply for Controllers, Photocell and Occupancy Sensors • Photocell provides energy savings through Daylight Harvesting technology • Use with Leviton Occupancy Sensors for increased energy savings: Lights turn ON automatically to programmed levels when personnel enter area; OFF automatically when area becomes vacant • Modular system design expands energy saving options with an interface for building emergency systems, load shedding programs and time clock systems • Dimming Power Pack mounts in standard 4" square back box. Entry Station Wall Switch mounts in standard single-gang switch box. TESTING & CODE COMPLIANCE • *Agency approvals for all Centura components are UL, CSA, NOM, FCC, and California Title 24 (where applicable) except for the handheld remote controller For more information on the Centura™ Fluorescent Energy Management System, visit Leviton’s website at www.leviton.com/centura For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 P4 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Commercial Grade Occupancy Sensor Lighting Controls Self-Contained Ceiling-Mount Occupancy Sensor PIR Occupancy Sensor with built-in relay—Separate Power Pack not required DESCRIPTION CAT. NO. RATING COVERAGE COLOR Self-Contained Ceiling-Mount Infrared Occupancy Sensor and Switching Relay ODC0S-I1W (formerly 16786-120) Incandescent: 1000W @ 120V. Fluorescent: 1000VA @ 120V. 1 HP @ 120V For 60Hz AC only 360°, 530 sq. ft White Self-Contained Ceiling-Mount Infrared Occupancy Sensor and Switching Relay ODC0S-I2W Incandescent: 1000W @ 220V. Fluorescent: 500VA @ 220V. For 50Hz AC only 360°, 530 sq. ft White Self-Contained Ceiling-Mount Infrared Occupancy Sensor and Switching Relay ODC0S-I7W (formerly 16786-277) Fluorescent: 2700VA @ 277V. For 60Hz AC only 360°, 530 sq. ft White Protective Cage ODCCG — — White ODC0S-I1W All devices are UL Listed and CSA Certified. 2.15 (54.6 mm) SPECIFICATIONS & FEATURES • Ideal for use in storage areas, small bathrooms, copy rooms and a variety of small spaces without wall switches • Full 360° view of a 530 sq. ft. area when surface mounted on standard, 8-foot ceiling • Sensor and switching relay combined in a single self-contained unit—No control unit required • Ambient light override option prevents lights from turning ON when there is ample natural light • Adjustable Delayed-OFF time settings from 20 seconds (for test mode) to 15 minutes • Small, unobtrusive self-contained unit: 4.3" (109.2 mm) diameter TESTING & CODE COMPLIANCE • UL Listed • CSA Certified 4.3 (109.2 mm) Cat. No. ODC0S-I1W P5 For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 ....Building a Connected World Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Occupancy Sensor Lighting Controls Commercial Grade Multi-Technology Ceiling-Mount Occupancy Sensor (For use with Leviton Power Pack)* Advanced motion sensors combine infrared and ultrasonic technology for highly accurate monitoring without false triggering. All-digital self-adjusting technology provides “Install and Forget” solution for automatic lighting control DESCRIPTION CAT. NO. COVERAGE OPERATING FREQUENCY COLOR Multi-Tech Ceiling-Mount Occupancy Sensor ODC05-M0W 180°, 500 sq. ft 40kHz White Multi-Tech Ceiling-Mount Occupancy Sensor with Ambient Light Override and Secondary Relay ODC05-MRW 180°, 500 sq. ft 40kHz White Multi-Tech Ceiling-Mount Occupancy Sensor ODC10-M0W 180°, 1000 sq. ft 32kHz White Multi-Tech Ceiling-Mount Occupancy Sensor with Ambient Light Override and Secondary Relay ODC10-MRW 180°,1000 sq. ft 32kHz White Multi-Tech Ceiling-Mount Occupancy Sensor ODC20-M0W 360°, 2000 sq. ft 32kHz White Multi-Tech Ceiling-Mount Occupancy Sensor with Ambient Light Override and Secondary Relay ODC20-MRW 360°, 2000 sq. ft 32kHz White Hard-Ceiling Raceway Adapter Kit ODCRA-000 — — White Protective Cage for Ceiling-Mount Occupancy Sensors ODCCG-000 — — White ODC20-M0W *Low-voltage wiring is used to connect Leviton Occupancy Sensors to Cat. No. ODP20 Power Pack (purchased separately). See page P11 for Power Pack information. All devices are CUL/US Certified. 1.40 (35.6 mm) ø 4.53 (115.1 mm) SPECIFICATIONS & FEATURES Cat. Nos. ODC050-M, ODC10-M 1.40 (35.6 mm) ø 4.53 (115.1 mm) • Ideal for office areas with cubicles, general work space, warehouse and storage facilities, cafeterias and public areas in commercial facilities • Ultrasonic sensing for maximum sensitivity combined with Passive Infrared (PIR) sensing to prevent false triggering from air conditioning and corridor activity • Self-adjusting settings continuously analyze and adjust infrared sensitivity, timer operation, and air current compensation for reliable, long-term performance • Automatic dual-mode operation adjusts to either economy or highsensitivity mode based on actual occupancy patterns for maximum energy savings • Built-in Circadian Calendar — Provides 4-week learning period where the sensor monitors occupancy to establish trends that serve as the basis for automatic operation. During peak occupancy periods the sensor remains in highsensitivity mode and during low occupancy periods it switches to economy mode. • Manual Delayed-OFF time settings of 8, 16, and 32 minutes, with 8-second test mode • Self-Adjusting Delayed-OFF time interval settings for 8 to 100 minutes — Compensates for real-time occupancy patterns, preventing unnecessary ON/OFF switching • Non-volatile memory preserves all automatic and manual settings during power outages • Choice of coverage patterns to suits a variety of applications • Small, unobtrusive size (4.5" diameter) blends in with any décor • Fast, simple installation using 3 color-coded low-voltage wires and a single mounting post • Hard-Ceiling Raceway Adapter Kit (optional) provides complete solution for mounting occupancy sensors to hard ceilings. Two-piece kit contains Adapter Base and “rotate and lock” Adapter Plate for attaching Sensor. Compatible with most standard surface-mounting raceways; also suitable for mounting Sensors to standard octagonal J box Optional Performance Features (Models with -MRW suffix) • Ambient light override option prevents lights from turning ON when there is ample natural light • Secondary Relay — Single-Pole Double-Throw (SPDT), rated 500 mA @ 24V AC/DC, three-wire isolated relay • Secondary Relay can be used to send control signals to HVAC systems based on occupancy detection TESTING & CODE COMPLIANCE • CUL/US Certified Cat. No. ODC20-M For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 P6 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Commercial Grade Occupancy Sensor Lighting Controls Ultrasonic Ceiling-Mount Occupancy Sensor (For use with Leviton Power Pack)* Advanced Ultrasonic sensing technology for highly accurate monitoring with excellent immunity to air currents and other interference . All-digital self-adjusting technology provides “Install and Forget” solution for automatic lighting control. ODC10-U0W DESCRIPTION CAT. NO. COVERAGE OPERATING FREQUENCY COLOR Ultrasonic Ceiling-Mount Occupancy Sensor ODC05-U0W 180°, 500 sq. ft 40kHz White Ultrasonic Ceiling-Mount Occupancy Sensor with Ambient Light Override and Secondary Relay ODC05-URW 180°, 500 sq. ft 40kHz White Ultrasonic Ceiling-Mount Occupancy Sensor ODC10-U0W 180°, 1000 sq. ft 32kHz White Ultrasonic Ceiling-Mount Occupancy Sensor with Ambient Light Override and Secondary Relay ODC10-URW 180°, 1000 sq. ft 32kHz White Ultrasonic Ceiling-Mount Occupancy Sensor ODC20-U0W 360°, 2000 sq. ft 32kHz White Ultrasonic Ceiling-Mount Occupancy Sensor with Ambient Light Override and Secondary Relay ODC20-URW 360°, 2000 sq. ft 32kHz White Hard-Ceiling Raceway Adapter Kit ODCRA-000 — — Protective Cage for Ceiling-Mount Occupancy Sensors ODCCG-000 White White — — *Low-voltage wiring is used to connect Leviton Occupancy Sensors to Cat. No. ODP20 Power Pack (purchased separately). See page P11 for Power Pack information. All devices are CUL/US Certified. 1.40 (35.6 mm) SPECIFICATIONS & FEATURES • Ideal for restrooms, office areas with cubicles, general work space, warehouse and storage facilities, cafeterias and public areas in commercial facilities • Ultrasonic sensing for maximum range and sensitivity combined with high immunity to false triggering from air currents and other interference • Self-adjusting settings continuously analyze and adjust sensitivity, timer operation, and air current compensation for reliable, long-term performance • Automatic dual-mode operation adjusts to either economy or highsensitivity mode based on actual occupancy patterns for maximum energy savings • Built-in Circadian Calendar — Provides 4-week learning period where the sensor monitors occupancy to establish trends that serve as the basis for automatic operation. During peak occupancy periods the sensor remains in high-sensitivity mode and during low occupancy periods it switches to economy mode. • Manual Delayed-OFF time settings of 8, 16, and 32 minutes, with 8-second test mode • Self-Adjusting Delayed-OFF time interval settings for 8 to 100 minutes — Compensates for real-time occupancy patterns, preventing unnecessary ON/OFF switching • Non-volatile memory preserves all automatic and manual settings during power outages • Choice of coverage patterns to suit a variety of applications • Small, unobtrusive size (4.5" diameter) blends in with any décor • Fast, simple installation using 3 color-coded low-voltage wires and a single mounting post • Hard-Ceiling Raceway Adapter Kit (optional) provides complete solution for mounting occupancy sensors to hard ceilings. Two-piece kit contains Adapter Base and “rotate and lock” Adapter Plate for attaching Sensor. Compatible with most standard surface-mounting raceways; also suitable for mounting Sensors to standard octagonal J box Optional Performance Features (Models with -URW suffix) • Ambient light override option prevents lights from turning ON when there is ample natural light • Secondary Relay — Single-Pole Double-Throw (SPDT), rated 500 mA @ 24V AC/DC, three-wire isolated relay • Secondary Relay can be used to send control signals to HVAC systems based on occupancy detection ø 4.53 (115.1 mm) Cat. Nos. ODC05-U, ODC010-U 1.40 (35.6 mm) ø 4.53 (115.1 mm) TESTING & CODE COMPLIANCE • CUL/US Certified Cat. No. ODC20-U P7 To learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com ....Building a Connected World Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Occupancy Sensor Lighting Controls Commercial Grade Infrared Ceiling-Mount Occupancy Sensor (For use with Leviton Power Pack)* Advanced Passive Infrared technology for highly accurate monitoring in a variety of commercial applications. All-digital self-adjusting technology provides “Install and Forget” solution for automatic lighting control. DESCRIPTION CAT. NO. COVERAGE COLOR Infrared Ceiling-Mount Occupancy Sensor ODC04-I0W 360°, 450 sq. ft White Infrared Ceiling-Mount Occupancy Sensor with Ambient Light Override and Secondary Relay ODC04-IRW 360°, 450 sq. ft White Hard-Ceiling Raceway Adapter Kit ODCRA-000 — White Protective Cage for Ceiling-Mount Occupancy Sensors ODCCG-000 — White ODC04-10W *Low-voltage wiring is used to connect Leviton Occupancy Sensors to Cat. No. ODP20 Power Pack (purchased separately). See page P11 for Power Pack information. All devices are CUL/US Certified. 1.40 (35.6 mm) ø 4.53 (115.1 mm) Cat. No. ODC04-I SPECIFICATIONS & FEATURES • Ideal for use in small offices, general work areas, closets, restrooms, and other small areas in commercial facilities • Self-adjusting settings continuously analyze and adjust infrared sensitivity, timer operation, and air current compensation for reliable, long-term performance • Automatic dual-mode operation adjusts to either economy or highsensitivity mode based on actual occupancy patterns for maximum energy savings • Built-in Circadian Calendar — Provides 4-week learning period where the sensor monitors occupancy to establish trends that serve as the basis for automatic operation. During peak occupancy periods the sensor remains in high-sensitivity mode and during low occupancy periods it switches to economy mode. • Manual Delayed-OFF time settings of 8, 16, and 32 minutes, with 8-second test mode • Self-Adjusting Delayed-OFF time interval settings for 8 to 100 minutes — Compensates for real-time occupancy patterns, preventing unnecessary ON/OFF switching • Non-volatile memory preserves all automatic and manual settings during power outages • Small, unobtrusive size (4.5" diameter) blends in with any décor • Fast, simple installation using 3 color-coded low-voltage wires and a single mounting post • Hard-Ceiling Raceway Adapter Kit (optional) provides complete solution for mounting occupancy sensors to hard ceilings. Two-piece kit contains Adapter Base and “rotate and lock” Adapter Plate for attaching Sensor. Compatible with most standard surface-mounting raceways; also suitable for mounting Sensors to standard octagonal J box Optional Performance Features (Models with -IRW suffix) • Ambient light override option prevents lights from turning ON when there is ample natural light • Secondary Relay — Single-Pole Double-Throw (SPDT), rated 500 mA @ 24V AC/DC, three-wire isolated relay • Secondary Relay can be used to send control signals to HVAC systems based on occupancy detection TESTING & CODE COMPLIANCE • CUL/US Certified For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 ....Building a Connected World P8 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Commercial Grade Occupancy Sensor Lighting Controls Multi-Technology Wall-Mount Occupancy Sensor (For use with Leviton Power Pack)* Advanced motion sensors combine infrared and ultrasonic technology for highly accurate monitoring without false triggering. All-digital self-adjusting technology provides “Install and Forget” solution for automatic lighting control ODW12-M0W DESCRIPTION CAT. NO. COVERAGE OPERATING FREQUENCY COLOR Multi-Tech Wall-Mount Occupancy Sensor ODW12-M0W 110°, 1200 sq. ft 32kHz White Multi-Tech Wall-Mount Occupancy Sensor with Ambient Light Override and Secondary Relay ODW12-MRW 110°, 1200 sq. ft 32kHz White *Low-voltage wiring is used to connect Leviton Occupancy Sensors to Cat. No. ODP20 Power Pack (purchased separately). See page P11 for Power Pack information. All devices are CUL/US Certified. • Ideal for conference rooms, stairwells, high-ceiling rooms, open areas, storage rooms and classrooms. Also ideal for corner mounting in a variety of applications. • Ultrasonic sensing for maximum sensitivity combined with Passive Infrared (PIR) sensing to prevent false triggering from air conditioning and corridor activity • Adjustable swivel neck rotates 80° vertically and 60° horizontally— Can be used for ceiling or wall mounting • Self-adjusting settings continuously analyze and adjust infrared sensitivity, timer operation, and air current compensation for reliable, long-term performance • Automatic dual-mode operation adjusts to either economy or highsensitivity mode based on actual occupancy patterns for maximum energy savings • Built-in Circadian Calendar— Provides 4-week learning period where the sensor monitors occupancy to establish trends that serve as the basis for automatic operation. During peak occupancy periods the sensor remains in high-sensitivity mode and during low occupancy periods it switches to economy mode. • Manual Delayed-OFF time settings of 4, 8, 16, and 32 minutes, with 8-second test mode P9 • Self-Adjusting Delayed-OFF time interval settings for 4 to 100 minutes—Compensates for real-time occupancy patterns, preventing unnecessary ON/OFF switching • Non-volatile memory preserves all automatic and manual settings during power outages • Fast, simple installation using 3 color-coded low-voltage wires and a single mounting post Optional Performance Features (Models with -MRW suffix) • Ambient light override option prevents lights from turning ON when there is ample natural light • Secondary Relay—Single-Pole Double-Throw (SPDT), rated 500 mA @ 24V AC/DC, three-wire isolated relay • Secondary Relay can be used to send control signals to HVAC systems based on occupancy detection TESTING & CODE COMPLIANCE • CUL/US Certified 5.29 (134.4 mm) SPECIFICATIONS & FEATURES 6.58 (167.1 mm) ø 3.63 (92.2 mm) 3.72 (94.5 mm) 2.73 (69.3 mm) Cat. No. ODW12-M To learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com ....Building a Connected World Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Occupancy Sensor Lighting Controls Commercial Grade Infrared Wide-View and High-Bay Wall Mount Occupancy Sensors (For use with Leviton Power Pack)* Advanced Passive Infrared technology for highly accurate monitoring in a variety of commercial applications. All-digital self-adjusting technology provides “Install and Forget” solution for automatic lighting control. Wide-View DESCRIPTION CAT. NO. COVERAGE COLOR Infrared Wide-View Wall-Mount Occupancy Sensor ODWWV-I0W 110°, 2500 sq. ft White Infrared Wide-View Wall-Mount Occupancy Sensor with Ambient Light Override and Secondary Relay ODWWV-IRW 110°, 2500 sq. ft White DESCRIPTION CAT. NO. COVERAGE COLOR Infrared High-Bay Wall-Mount Occupancy Sensor ODWHB-I0W 120 ft, 14 ft wide @ 30 ft height White Infrared High-Bay Wall-Mount Occupancy Sensor with Ambient Light Override and Secondary Relay ODWHB-IRW 120 ft, 14 ft wide @ 30 ft height White High-Bay ODWWV-I0W, ODWHB-I0W *Low-voltage wiring is used to connect Leviton Occupancy Sensors to Cat. No. ODP20 Power Pack (purchased separately). See page P11 for Power Pack information. All devices are CUL/US Certified. 5.29 (134.4 mm) 6.58 (167.1 mm) ø 3.63 (92.2 mm) 3.72 (94.5 mm) 2.73 (69.3 mm) Cat. Nos. ODWWV-I, ODWHB-I SPECIFICATIONS & FEATURES • ODWWV-I: Ideal for conference rooms, stair-wells, high-ceiling rooms, large open areas, parking garages, storage rooms and rooms with pendant fixtures. Also ideal for corner mounting in a variety of applications. • ODWHB-I: Ideal for monitoring long, narrow spaces such as warehouse aisles, hallways, stairways, any narrow room, closets and storage areas. Also ideal for corner mounting in a variety of applications. • Self-adjusting settings continuously analyze and adjust infrared sensitivity, timer operation, and air current compensation for reliable, long-term performance • Adjustable swivel neck rotates 80° vertically and 60° horizontally—Can be used for ceiling or wall mounting • Automatic dual-mode operation adjusts to either economy or highsensitivity mode based on actual occupancy patterns for maximum energy savings • Built-in Circadian Calendar— Provides 4-week learning period where the sensor monitors occupancy to establish trends that serve as the basis for automatic operation. During peak occupancy periods the sensor remains in highsensitivity mode and during low occupancy periods it switches to economy mode. • Manual Delayed-OFF time settings of 4, 8, 16, and 32 minutes, with 8-second test mode • Self-Adjusting Delayed-OFF time interval settings for 4 to 100 minutes — Compensates for real-time occupancy patterns, preventing unnecessary ON/OFF switching • Non-volatile memory preserves all automatic and manual settings during power outages • Fast, simple installation using 3 color-coded low-voltage wires and a single mounting post Optional Performance Features (Models with -IRW suffix) • Ambient light override option prevents lights from turning ON when there is ample natural light • Secondary Relay—Single-Pole Double-Throw (SPDT), rated 500 mA @ 24V AC/DC, three-wire isolated relay • Secondary Relay can be used to send control signals to HVAC systems based on occupancy detection TESTING & CODE COMPLIANCE • CUL/US Certified For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 ....Building a Connected World P10 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Occupancy Sensor Lighting Controls Commercial Grade Power Packs for Occupancy Sensors (For use with Leviton Occupancy Sensors listed on pages P6–P10)* Leviton Power Pack units contain both a 24V DC power supply for Occupancy Sensors and a relay for switching incandescent or fluorescent ballast lighting loads. Add-A-Relay units can be used to expand control capability. Compact, lightweight Power Pack and Add-A-Relay units are easily mounted inside or outside a junction box or inside a fluorescent ballast cavity. ODP20-010 DESCRIPTION CAT. NO. POWER INPUT RELAY RATING CONTROL INPUT POWER SUPPLY OUTPUT Power Pack, 120V ODP20-010 120V AC 60Hz 13A Incandescent, 5mA, 24V DC 20A Fluorescent Power Pack, 230V ODP20-020 230V AC 50 & 60Hz 20A Fluorescent 5mA, 24V DC 100mA, 24V DC Power Pack, 277V ODP20-070 277V AC 60Hz 20A Fluorescent 5mA, 24V DC 100mA, 24V DC Power Pack, 347V ODP15-030 347V AC 60Hz 15A Fluorescent 5mA, 24V DC 100mA, 24V DC Add-A-Relay Unit ODA00-000 — All Ratings Listed Above 5mA, 24V DC — 100mA, 24V DC All devices are CUL/US Certified. Power Pack Adapter DESCRIPTION CAT. NO. Low-Voltage Nipple Adapter with 1/2" Lock Nut for Power Pack and Add-A-Relay units ODPNA Power Pack Capacity Guide One Leviton Power Pack will supply power for a combination of up to 3 devices (Sensors and Add-A-Relay units) in the following configurations listed below. Allowable Load Configurations Power Pack • For use with the following Leviton Occupancy Sensors: ODC20-M, ODC10-M, ODC05-M, ODC20-U, ODC10-U, ODC05-U, ODC04-I, ODW12-M, ODWWV-I and ODWHB-I • Self-contained power supply for occupancy sensors and switching relay for lighting loads • Provides 24V DC 100 mA nominal, full-wave rectified and filtered power for occupancy sensors and Add-ARelay units (see Power Pack Capacity Guide) • Available in 120VAC, 230VAC, 277VAC and 347VAC versions with relay contacts rated for incandescent or lighting ballast loads • Compact size and light weight (15-oz.) allows easy mounting through knockout in junction box (from either inside or outside the box) with a simple twist-on nut. Also mounts inside fluorescent ballast cavity. Number of Add-A-Relay Units 1 0 2 0 3 0 1 1 2 1 1 2 Add-A-Relay • Expands Power Pack load capacity by functioning as a supplementary relay • Provides ability to switch loads in different voltage systems (For example, switching 120V incandescent loads in a 277V fluorescent system and vice versa) • Compatible with electronic ballasts • Same compact size and mounting features as Power Pack Nipple Adapter • Simplifies the connection of any OD-series Occupancy Sensor to the low-voltage side of a Power Pack mounted inside a fluorescent ballast cavity • 1/2" conduit lock nut included 2.35 (59.7 mm) TESTING & CODE COMPLIANCE • Power Pack Units are CUL/US Certified • Backed by a Limited Five-Year Warranty COLOR Power Pack and Add-A-Relay devices are black. P11 1.38 (35.1 mm) 3.66 (93.0 mm) SPECIFICATIONS & FEATURES Number of Occupancy Sensors ALL POWER PACK AND ADD-A-RELAY UNITS For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 ....Building a Connected World Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Occupancy Sensor Lighting Controls Commercial Grade Outdoor Motion Sensors Passive Infrared (PIR) outdoor motion sensor provide outstanding value in security lighting, convenience, safety and energy savings for a wide range of commercial and residential applications. Commercial Grade DESCRIPTION CAT. NO. RATING COVERAGE COLOR Professional Series Outdoor PIR Motion Sensor PS200-10 Incandescent: 1000W @ 120V. Fluorescent/Inductive: 500VA @ 120V. For 60Hz AC only 200° W, B Professional Series Outdoor PIR Motion Sensor with Dual Floodlights PS200-1F Incandescent: 1000W @ 120V. Fluorescent/Inductive: 500VA @ 120V. For 60Hz AC only Professional Series Outdoor PIR Motion Sensor PS110-10 Incandescent: 1000W @ 120V. Fluorescent/Inductive: 500VA @ 120V. For 60Hz AC only 110° W, B Professional Series Outdoor PIR Motion Sensor with Dual Floodlights PS110-1F Incandescent: 1000W @ 120V. Fluorescent/Inductive: 500VA @ 120V. For 60Hz AC only 110° W, B DESCRIPTION CAT. NO. RATING COVERAGE Residential Series Outdoor PIR Motion Sensor RS110-10 Incandescent: 500W @ 120V. Fluorescent/Inductive: 500VA @ 120V. For 60Hz AC only 110° W, B Residential Series Outdoor PIR Motion Sensor with Dual Floodlights RS110-1F Incandescent: 500W @ 120V. Fluorescent/Inductive: 500VA @ 120V. For 60Hz AC only. 110° W, B Residential Series Outdoor PIR Motion Sensor with Dual Floodlights RS110-2FW Incandescent: 500W @ 220V. Fluorescent/Inductive: 500VA @ 220V. For 50Hz AC only. 110° W only W, B 200° PS2000 Residential Grade COLOR All devices are UL Listed and CSA Certified. SPECIFICATIONS & FEATURES 9.16 (232.7 mm) 2.48 (63.0 mm) 4.50 (114.3 mm) 5.36 (136.1 mm) Cat. No. PS2000 Professional Series • Ideal for a wide range of commercial/industrial settings including parking areas, storage facilities, warehouses, loading docks, marina, garages, walkways, campus grounds, meat lockers, walk-in refrigerators/freezers and outbuildings • Adjustable Delayed-OFF time settings from 20 seconds (for test mode) to 15 minutes • Adjustable sensitivity and immunity to RFI signals reduces false triggers • Ambient light override prevents lights from turning ON when there is ample natural light • Provides Automatic, Test and Continuous Modes—Test mode simulates automatic operation with short delayed-OFF time for ease of making adjustments. Continuos mode enables manual override for constant “lights ON” operation (when used with standard ON/OFF switch) • Surge suppression minimizes likelihood of damage due to electrical surges • Temperature compensation feature ensures uniform performance in extreme hot or cold weather and during temperature fluctuations • Sensor neck adjustment allows accurate area monitoring: 110° vertical, 180° horizontal, 110° rotational For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 Residential Series • Ideal for a wide range of residential settings including backyards, garages, entranceways, porches, swimming pool areas, doorways and private docks • Sensor neck adjustment allows accurate area monitoring: 110° vertical, 180° horizontal, 110° rotational • Adjustable Delayed-OFF time settings from 20 seconds (for test mode) to 15 minutes • Adjustable sensitivity reduces false triggers • Provides Automatic, Test and Continuous Modes—Test mode simulates automatic operation with short delayed-OFF time for ease of making adjustments. Continuos mode enables manual override for constant “lights ON” operation (when used with standard ON/OFF switch) TESTING & CODE COMPLIANCE • UL Listed • CSA Certified COLOR Colors available as listed. For color selections, add suffix to catalog numbers as follows: White (-W) and Brown (-B). P12 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com How To Use This Catalog This edition of the Leviton Wiring Device Catalog has been re-designed to help you find the device you’re seeking in the quickest and easiest way possible. To achieve this, each Section (A, B, C, etc.) has been divided into three distinct portions in the following sequence—Industrial Grade first, Commercial Grade second, Residential Grade third—and grouped according to their amperage and voltage, lowest to highest. (Some product classes may have slight differences.) If you need to place an order for any quantity of 15 Amp, 125 Volt, Industrial Grade duplex receptacles with back and side wiring, you would begin your search for the right Leviton product with the Table of Contents. Here you’ll see that all receptacles are listed in Section D. Turning to Section D, you’ll find that product descriptions now lead off each listing, so that you’ll be able to understand what the device is about, functionally, in relation to your needs. Product description, in turn, is followed by Amps and catalog numbers for ordering purposes. To assist you further, such helpful highlights as Specifications & Features, Testing & Code Compliance, Color listing, Material Characteristics, color photos and dimensional drawings virtually fill each page. Four-color photographs have been added throughout the catalog to provide you with an enhanced view of the Leviton product line. Any page in this L-504 Catalog can be used as a specificer sheet or as part of a presentation; and any page can be clearly faxed to customers and prospects. Product classes may also be pinpointed in the Quick Reference Guide following the Table of Contents. After turning to the proper page, you would locate the catalog number for the item that corresponds to your needs, along with basic information about similar items. Wiring diagrams, NEMA Configuration Charts, Electrical Industry Definitions, ANSI Architectural Symbols, and other related information can be found in the Technical Section (U). Specific product catalog A Straight Blade Receptacles Industrial Grade E D Back and Side Wired (Basic Cat. No. Denotes Brown Device*) DESCRIPTION B C CAT. NO./COLOR 15A/125V G G 5-15R 5262-I • Impact-resistant thermoplastic nylon cover and body • Smooth face does not collect dirt • Four corner latches securely fasten face • Locked-in mounting strap • Large, triple-wipe, brass “T” contacts for superior contact and conductivity W 6-15R 5-20R G 5462 5662 I 5362 I, W, GY, R, E Single Receptacle 5261 I, W, GY 5661 I 5361 I, W, GY, A, E 5461 I, A, GY Narrow Body Duplex Receptacle 5252 I, W (No Brown) — 5352 I, W (No Brown) — 5361-CH Stainless Steel — HSingle g p Receptacle, I 5261-CH Stainless Steel — I, W I I, GY Back and Side Wired Dual Voltage (Basic Cat. No. Denotes Brown Device*) DESCRIPTION RATING CAT. NO. COLOR Duplex Receptacle 15A 125V/15A 250V 5292 I I All devices are UL Listed and CSA Certified. 1.09 (27.7 mm) 1.56 (39.6 mm) K Basic Cat. Nos. shown above denote Brown device. For other color selections, add suffix to the catalog number as follows: Ivory (-I), White (-W), Brown , Almond (-A), Gray (-G or -GY), Black (-E), Red (-R) and Blue (-BU). 3.28 (83.3 mm) 2.38 (60.3 mm) 4.06 (103.2 mm) 4.06 (103.2 mm) J 3.27 (83.1 mm) 2.78 (70.6 mm) *COLOR G 6-20R 5262 I, W, GY, R, E TESTING & CODE COMPLIANCE • UL Listed 498 (UL File #13399); UL Federal Specification WC-596 • CSA Certified where applicable (CSA File #LR-406) • NOM Certified (#057) • Backed by a Limited 10-Year Warranty G W Duplex Receptacle, Brass Strap Clockhanger SPECIFICATIONS & FEATURES F CAT. NO./COLOR CAT. NO./COLOR CAT. NO./COLOR 15A/250V 20A/125V 20A/250V 0.84 (21.4 mm) 1.31 (33.3 mm) 1.06 (27.0 mm) BACK & SIDE WIRED Cat. No. 5252 SINGLE RECEPTACLE Cat. No. 5361 A Choose GRADE, if appropriate E Select RATING and WIRING I TESTING & CODE COMPLIANCE B PHOTOGRAPH F Check for NEMA CONFIGURATION J COLOR LISTING C Check for SINGLE or DUPLEX G COLOR ABBREVIATIONS H SPECIFICATIONS & FEATURES K DIMENSIONAL ILLUSTRATIONS MATERIAL CHARACTERISTICS Environmental: Flammability, Rated V2 D Find AMPERAGE P13 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com