DCG31 & DCG32 SERIES COMMERCIAL GAS DAMPERED WATER HEATERS Check for 24V between black and white wires on ignition control module YES When thermostat NO turned up, does pilot spark? YES YES Check for 24V between PV & PV/MV terminals on gas valve NO Does sparking stop? YES Replace gas valve NO Replace ignition control Replace ignition control module Check for 24V between PV and PV/MV terminals on ignition control module Check for 24V between yellow and white wires on damper harness YES Check spark wire for damage & continuity. Also check spark assembly FOUND ALL for cracks in DAMAGE OKAY ceramic or wrong spark gap Clean flame sensor - check ground. If still problem, see below Problem is either bad spark assembly or wiring between spark assembly and control module Replace lower sensor/ ECO YES NO NO Check for 24V between PV & MV/PV terminals on ignition control module NO YES Replace faulty component Does main burner fire? NO YES Is there 24V between MV & MV/PV terminals at gas valve? Go to NO thermostat troubleshooting chart FC31/32-0805 YES Does main burner stay lit until thermostat satisfies? NO Does pilot light shrink or go out when main burner fires? YES Is gas flex being used, or other small gas pipe? Check for blockage in burner or orifice, also check incoming gas supply NO Bypass damper, if heater fires then replace damper Go to thermostat troubleshooting flow chart Replace ignition control Is there 24V between MV & MV/PV terminals at ignition control module? NO YES ALL SHOULD BE OKAY NO Repair ground Does pilot ignite? YES NO Is ground good from control module to incoming ground? NO YES OK Replace gas valve Check & adjust gas pressure OK Copyright© by American Water Heater Company 2005. All rights reserved. Replace ignition control module YES DCG31 & DCG32 SERIES COMMERCIAL GAS DAMPERED WATER HEATER THERMOSTAT No voltage or low voltage from yellow wire between thermostat board & damper Replace bad sensor With an ohm meter set at X1, check orange NO wires on set pot (6,000 ohms at lowest setting & 0 ohms at highest setting Replace set pot Ohm reading no good OK Has bad spot When slowly turning set pot dial from low to high, ohm reading should be a smooth transition with no skips, jumps or glitches OK Take ohm reading from upper sensor and lower sensor and compare reading with chart on next page (A termperature reading from a water sample taken from the T&P valve is also needed for this test) Ohms show OK Replace thermostat circuit board Sequence of Operation: When thermostat contacts close on a call for heat, a 24 Volt signal is sent to the damper and cause it to open. When the damper proves fully open, the 24 Volt signal continues to the ignition control module will then start sparking at the pilot head while at the same time sending 24 volts to the pilot valve portion of the gas valve to open it and allow the main burner to light. The main burner will continue to fire until the thermostat system is satisfied and opens the thermostat contacts, causing the damper to close and the ignition control module to shut down. FC31/32-0805 Copyright© by American Water Heater Company 2005. All rights reserved.