Safety switches with separate actuator

advertisement
4A
Safety switches with separate actuator
Selection diagram
VF KEYF
VF KEYF1
VF KEYF2
VF KEYF3
VF KEYF7
VF KEYF8
ACTUATORS
CONTACT
BLOCKS
FD
FP
FL
FC
5
1NO+1NC
snap action
20
1NO+2NC
slow action
6
1NO+1NC
slow action
21
3NC
slow action
7
1NO+1NC
slow action
overlapped
22
2NO+1NC
slow action
9
2NC
slow action
33
1NO+1NC
slow action
34
2NC
slow action
CONDUIT ENTRIES
Threaded conduit entries
(standard)
With cable gland
assembled
With M12 plastic
connector assembled and
wired
With M12 metal connector assembled and wired
PRODUCTOPTION
ACCESSORYSOLDSEPARATELY
4/3
General Catalog 2013-2014
4A
Code structure
Attention! The feasibility of a code number does not mean the effective availability of a product. Please contact our sales office.
article
options
FD 693-F1GM2K50
Preinstalled cable gland or connectors
Housing
FD
metal housing, one conduit entry
FL
metal housing, three conduit entries
FP
polymer housing, one conduit entry
no cable gland or connector (standard)
K21
...
with assembled cable gland suitable for Ø 6 to
Ø 12 mm cables range
........................
K50 with assembled 5 poles M12 metal connector
Contact blocks
...
5
1NO+1NC, snap action
6
1NO+1NC, slow action
7
1NO+1NC, slow action overlapped
9
2NC, slow action
20
1NO+2NC, slow action
21
3NC, slow action
22
2NO+1NC, slow action
33
1NO+1NC, slow action
34
2NC, slow action
........................
For the complete list of all combinations, please contact our technical
office.
Threaded conduit entry
PG 13,5 (standard)
M2 M20x1,5
Actuators
Contacts type
without actuator (standard)
F
with straight actuator
F1
with right-angled actuator
F2
with jointed actuator
F3
with jointed actuator adjustable in two
directions
F7
with jointed actuator adjustable in one
direction
F8
with universal actuator
silver contacts (standard)
G
article
silver contacts gold plated 1 µm
options
FC 3393-F1GM1K22
Housing
FC
Preinstalled cable gland
metal housing, one conduit entry
no cable gland (standard)
Contact blocks
33
1NO+1NC, slow action
34
2NC, slow action
with assembled cable gland suitable for Ø 5 to Ø 10 mm cables range
K26
with assembled cable gland suitable for Ø 3 to Ø 7 mm cables range
Threaded conduit entry
Actuators
PG 11 (standard)
without actuator (standard)
General Catalog 2013-2014
K22
M1 M16x1,5
F
with straight actuator
F1
with right-angled actuator
F2
with jointed actuator
Contacts type
F3
with jointed actuator adjustable in two
directions
F7
with jointed actuator adjustable in one
direction
G
F8
with universal actuator
silver contacts (standard)
silver contacts gold plated 1 µm
4/4
4A
Safety switches with separate actuator
Technical data
Housing
Housing type FP made of glass-reinforced polymer, self-extinguishing, shock-proof
thermoplastic resin and with double insulation .
Housing type FD, FL and FC made of metal, coated with baked epoxy powder.
FD, FP and FC series one conduit entry
FL series three conduit entries
Protection degree: IP67 according to EN 60529 with cable gland having equal or higher
protection degree
(electrical contacts)
General data
For safety applications up to SIL 3 / PL e
Safety parameters:
Ambient temperature:
see page 7/34
from -25°C to +80°C
Version for operation in ambient temperature from -40°C to +80° C on request
Main data
Metal housing or polymer housing, from one
to three conduit entries
Protection degree IP67
9 contact blocks available
6 stainless steel actuators available
M12 assembled connector versions
Silver contacts gold plated versions
Markings and quality marks:
Approval IMQ:
Approval UL:
Approval CCC:
EG605 (FD-FL-FC series)
EG606 (FP series)
E131787
2007010305230000
(FD-FL-FC series)
2007010305230014
(FP series)
Approval EZU:
Approval GOST: 1010151
POCC IT.AB24.B04512
Max actuation frequency: Mechanical endurance: Max actuating speed:
­Min. actuating speed:
Driving torque for installation:
3600 operations cycles1/hour
1 million operations cycles1
0,5 m/s
1 mm/s
see pages 7/1-7/12
(1) One operation cycle means two movements, one to close and one to open contacts, as foreseen by EN 609475-1 standard.
Cross section of the conductors (flexible copper wire)
Contact blocks 20, 21, 22, 33, 34:
min. 1 x 0,34 mm2
max. 2 x 1,5 mm2 Contact blocks 5, 6, 7, 9:
min. 1 x 0,5 mm2 max. 2 x 2,5 mm2 (1 x AWG 22)
(2 x AWG 16)
(1 x AWG 20)
(2 x AWG 14)
In conformity with standards:
IEC 60947-5-1, EN 60947-5-1, EN 60947-1, IEC 60204-1, EN 60204-1, EN 1088,
EN ISO 12100-1, EN ISO 12100-2, IEC 60529, EN 60529, NFC 63-140, VDE 0660-200,
VDE 0113, BG-GS-ET-15.
Approvals:
IEC 60947-5-1, UL 508, GB14048.5-2001.
In conformity with requirements requested by:
Low Voltage Directive 2006/95/EC, Machinery Directive 2006/42/EC and
Electromagnetic Compatibility 2004/108/EC.
Positive contact opening in conformity with standards:
IEC 60947-5-1, EN 60947-5-1, VDE 0660-206.
If not expressly indicated in this chapter, for the right installation and the correct utilization of all articles see requirements indicated
from page 7/1 to page 7/12.
without
connector
Thermal current (Ith): 10 A
Rated insulation voltage (Ui): 500 Vac 600 Vdc
400 Vac 500 Vdc (contact blocks 20, 21, 22, 33, 34)
Rated impulse withstand voltage (Uimp): 6 kV
4 kV (contact blocks 20, 21, 22, 33, 34)
Conditional shot circuit current: 1000 A according to EN 60947-5-1
Protection against short circuits: fuse 10 A 500 V type aM
Pollution degree: 3
Alternate current: AC15 (50...60 Hz)
Ue (V)
250
400
500
Ie (A)
6
4
1
Direct current: DC13
Ue (V)
24
125
250
Ie (A)
6
1,1
0,4
with 4 or 5 poles
M12 connector
Utilization categories
Thermal current (Ith): Rated insulation voltage (Ui): Protection against short circuits: Pollution degree: 4A
250 Vac 300 Vdc
fuse 4 A 500 V type gG
3
Alternate current: AC15 (50...60 Hz)
Ue (V)
24
120
250
Ie (A)
4
4
4
Direct current: DC13
Ue (V)
24
125
250
Ie (A)
4
1,1
0,4
with 8 poles
M12 connector
Electrical data
Thermal current (Ith): Rated insulation voltage (Ui): Protection against short circuits: Pollution degree: 2A
30 Vac 36 Vdc
fuse 2 A 500 V type gG
3
Alternate current: AC15 (50...60 Hz)
Ue (V)
24
Ie (A)
2
Direct current: DC13
Ue (V)
24
Ie (A)
2
4/5
General Catalog 2013-2014
4A
Description
These safety switches are ideal to control gates, sliding doors and other guards protecting dangerous parts of machine.
The stainless steel actuator is fastened to the moving part of the guard, so it is removed from the switch on every opening of the guard. The
switch mechanism guarantees that removing the actuator forces the positive opening of the electrical contacts. Easy to install, these switches
can be applied to any kind of protection (with hinge, sliding and removable ones). Besides, the possibility to actuate the switch only with its
actuator guarantees that the machine can be restarted only when the guard has been closed. Made of rugged materials and with oversized
thickness, these switches are designed for the use on heavy guards.
Rotating heads
Actuator regulation zone
Removing the two fastening
screws, in all switches, the
head can be rotated in 90°
steps.
Installation examples
0,5
...
5m
m
This switch has a wide backlash
of the actuator into the head (4,5
mm) for an easier installation.
With closed door, check that the
actuator doesn’t knock straight
against the head of the switch; it
must be in the adjustment zone
(0,5…5 mm)
Safety screws for actuators
These new screws have tamper-resistant Torx
buttonheads.
Devices fixed with this kind of screws cannot be
removed or tampered by common tools.
See Accessories page 6/5.
Limits of utilization
Do not use where dust and dirt may penetrate in any way into the
head and deposit there, in particular where metal dust, concrete or
chemicals are spread.
Do not use where explosive or inflammable gas is present.
Use Atex products in environments with explosion hazard (see page
2/137).
Data type approved by IMQ, CCC and EZU
Data type approved by UL
Rated insulation voltage (Ui): 500 Vac
400 Vac (for contact blocks 20, 21, 22, 33, 34)
Thermal current (Ith): 10 A
Protection against short circuits: fuse 10 A 500 V type aM
Rated impulse withstand voltage (Uimp): 6 kV
4 kV (for contact blocks 20, 21, 22, 33, 34)
Protection degree: IP67
MV terminals (screw clamps)
Pollution degree 3
Utilization category: AC15
Operation voltage (Ue): 400 Vac (50 Hz)
Operation current (Ie): 3 A
Forms of the contact element: Zb, Y+Y, Y+Y+X, Y+Y+Y, Y+X+X
Positive opening of contacts on contact block 5, 6, 7, 9, 20, 21, 22, 33, 34
Utilization categories Q300 (69 VA, 125-250 Vdc)
A600 (720 VA, 120-600 Vac)
Data of the housing type 1, 4X “indoor use only”, 12, 13
For all contact blocks use 60 or 75 °C copper (Cu) conductor and wire size
No. 12-14 AWG. Terminal tightening torque of 7,1 lb in (0.8 Nm).
In conformity with standard: UL 508
Please contact our technical service for the list of approved products.
In conformity with standards: EN 60947-1, EN 60947-5-1+ A1:2009, fundamental
requirements of the Low Voltage Directive 2006/95/CE.
Please contact our technical service for the list of approved products.
General Catalog 2013-2014
4/6
4A
Safety switches with separate actuator
Dimensional drawings
Metal housing
Metal housing
Metal housing
Switch without actuator
Switch without actuator
Switch without actuator
32
43
35
7
32
6
40
5.5
57
60
8
5.2x6.2
100
109.5
5.3x7.3
35
43
35
43
60
109
8
32
87
32
overlapped
8
35
43
8
8
R = snap action
L = slow action
LO = slow action
5.3x7.3
Polymer housing
Switch without actuator
8
Contacts type:
28.5
44
30
Contact blocks
5
FD 593
1NO+1NC
0
10
7
8.6
0 5.6
1NO+1NC
LO
10.5
20
5.8
FD 2093
8.8
5.8
22
5.8
FP 2293
L
8.8
0
5.8
5.8
FD 2293
8.8
0
FP 3393
L
0
FD 3393
1NO+1NC
5.3
8.3
0
FP 3493
L
0
8.5
10 N (18 N
Min. force
0
)
18
0
Max travel
11-12
6.5
23-24
7
NO closing
5.5
8.8
8.8
3NC
5.8
FL 2293
0
8.8
2NO+1NC
5.8
8.8
6.4
FL 3393
8.3
0
2NC
FL 3493
8.5
0
1NO+1NC
5.3
8.3
FC 3393
0
5.3
5.9
)
8.3
5.9
FC 3493
2NC
5.5
1NO+1NC
0
8.5
10 N (18 N
)
2NC
5.5
8.5
10 N (18 N
)
All measures in the diagrams are in mm
Example diagram
NC opening
4.5
8.8
1NO+2NC
5.8
6.4
10 N (18 N
How to read travel diagrams
0
FL 2193
5.9
FD 3493
2NC
5.5
3NC
1NO+1NC
5.3
5.9
34
0
6.4
6.4
33
FL 2093
8.8
2NO+1NC
5.8
10.2
7.2
6.4
FD 2193
2NO+1NC
0
2NC
0
1NO+2NC
0
3NC
0
FL 993
10.2
7.2
6.4
FP 2193
L
1NO+1NC
10.5
0 7.5
2NC
0
1NO+2NC
0
21
FL 793
5
FD 993
10.2
7.2
FP 2093
L
10.5
0 7.5
2NC
0
1NO+1NC
5
FP 993
L
7.5
FD 793
1NO+1NC
5
9
1NO+1NC
8.6
0 5.6
7.5
FP 793
0 7.5
FL 693
8.6
0 5.6
7.5
7
10
7
4.8
FD 693
1NO+1NC
33
1NO+1NC
0
4.8
FP 693
L
40
33
FL 593
10
7
4.8
6
56
30
38
1NO+1NC
0
14.5
14.3
30
40
30
39
FP 593
R
15
5.3
16
6.5
30
40
6
5.3
Closed contact
Open contact
IMPORTANT:
NC contact has to be considered with inserted actuator. In safety applications
it is necessary to activate the switch at least up to the positive opening point
indicated in the diagrams with the symbol . Operate the switch at least with the
positive opening force, indicated between brackets, below each article, next the
value of minimum force.
Positive opening travel
Accessories See page 6/1
Items with code on the green background are available in stock
All measures in the drawings are in mm
4/7
General Catalog 2013-2014
4A
Stainless steel actuators
IMPORTANT: These actuators must be used with FD, FP, FL, FC or FS series only (e.g. FD 693).
Article
Description
Article
VF KEYF1
Straight actuator
Description
Right-angled actuator
5.5
0
15
R>30
30
15
R>30
0
15
6
Description
Jointed actuator
R>500
2.5
10
4
12°
5°
0
2.5
Actuator adjustable in two directions for doors with reduced
dimensions.
Article
Description
Article
VF KEYF7
Jointed actuator adjustable in one direction
VF KEYF8
5.5
Description
Universal actuator
10
0
11
12°
12°
4.8
R
12°
r8
0
20
12°
Ø 4.2
Actuator adjustable in one direction for doors with reduced dimensions.
Rr
40
56
2.4
16
12°
2.5
2.5
R>500
8.6
26
10.8 13
6.5
37
°
11
32
5.2
r
5.2
30
16.2
80
16.2
39
28
R
8.5
R>500
12°
The actuator can flex in four directions for applications where the
door alignment is not precise.
R>
11
R>100
R>500
2.5
8°
32
12°
8°
32
26
R>
0
5°
24
4.2
R>500
22
10
7
16.2
26
8°
R>
20
0
4.5
11 13
Description
Jointed actuator adjustable in two directions
30
20
16.2
4.5
Article
VF KEYF3
16
R>30
7
32
7 13
30
20
8°
R>500
26
Article
2.5
32
VF KEYF2
10
16.2
26
R>500
R>500
26
30
16.2
Ø 5.5
15.3
22
10
80
15
6
VF KEYF
Joined and two directions adjustable actuator for doors with
reduced dimensions.
The actuator has two couples of fixing holes and it is possible to
rotate by 90° the actuator-working plan.
Accessories
Description
Article
VF KB1
Actuator entry locking device
Padlockable device to lock
the actuator entry in order to
prevent from the accidental
closing of the door behind
operators while they are
inside the machine. It cannot
be used for switches with
plastic heads.
General Catalog 2013-2014
4/8
Download