Diffinity RapidTip®2 – One minute purification! The Diffinity RapidTip2 effectively removes impurities from PCR samples prior to downstream applications, such as restriction digests, Sanger sequencing, or T-A cloning! Diffinity® technology in the RapidTip2 effectively removes dNTPs, primers, primer-dimers and DNA polymerase from your PCR sample while providing high recovery of DNA fragments ranging in length from 150bp to 10Kb. RapidTip2 dramatically reduces the amount of time to purify and prepare PCR reactions for use in downstream applications, such as restriction digest, T-A cloning, and Sanger cycle sequencing reactions. Automate your purification for an even faster workflow. Diffinity RapidTip®2 — it’s all in the tip! Purification of PCR products in one minute! No bind-wash-elute, enzymes, or magnetic beads! The Diffinity RapidTip2 functional pipette tip contains everything you need for PCR purification. The tip is filled with our proprietary adsorption technology that has a differential affinity for PCR reaction components. The impurities (e.g., single-stranded primers, nucleotides, and DNA polymerases used in the PCR process) are removed from the solution as it enters the pipette tip. Dispensing the solution yields purified, high quality DNA ready to use in your next application. You don’t need to use any capital equipment, reagents or buffers, or enzymes — all you need is a pipettor. Protocol — only a single purification step! Materials & Equipment • Diffinity RapidTip2 functional pipette tip — prepacked with our proprietary material and ready to use out of the box. • A pipettor or compatible robot. Results U C R Standard Hot Start Proofreading Diffinity RapidTip2 purifies PCR solutions and removes DNA polymerase (standard, HotStart, and Proofreading) comparably to popular spin column methods. PCR reactions were prepared and purified via a competitor’s product (C), RapidTip2 (R), or left unpurified (U). Then these reactions were placed in the thermocycler. Our sensitive assay generates a 600bp band when polymerase is present and no band when polymerase is absent. The unpurified (U) reaction contains a 600bp band that indicates polymerase is present. The control and RapidTip2 lanes have no detectable 600bp band indicating that polymerase was adequately removed. U C C ----RT2---1 2 3 2Kb-- • Optional: Microfuge tubes to store purified DNA. Method • Attach one or more of our pipette tips to a universal or Rainin LTS® P100/P200 pipettor (single or multichannel) or compatible robot. • Aspirate PCR product into the pipette tip and mix by pipetting up and down for approximately one minute. • Dispense purified PCR product into a clean tube or well and dispose of the tip in normal laboratory trash — that’s it! 50bp-20bp-Diffinity RapidTip2 effectively removes dNTPs (not visible on gel), primers (20bp), and primer-dimers (50bp). The PCR product was divided and subjected to PCR purification with either competitor’s products (C) or RapidTip2 (RT2: 1, 2, 3). RapidTip2 has high yield: the PCR amplicon (2Kb) shows no loss of band intensity after purification. Diffinity Genomics | Chiral Technologies, Inc. • 800 North Five Points Road • West Chester, PA 19380 • 877-362-1812 • www.diffinitygenomics.com Excellent Yield Recovers up to 90% of high quality dsDNA ready to use in subsequent applications. One Minute, One Step Extremely fast and efficient process to rapidly recover clean DNA. Effective Purification Up to 90% removal of dNTPs, primers, and primer dimers. Removes DNA polymerases to undetectable levels. Large Range of Fragment Length Returns pure DNA fragments of 150bp to 10kb. Cost Effective No capital equipment (e.g., centrifuge, magnetic extractor, vacuum manifold), extra plasticware, or liquids are required. Less labor time required due to simple protocol. Easy to Use Single step protocol requires little to no training of lab personnel. Simple protocol requires no complex operator techniques or interactions with equipment, buffers, or reagents. Robot Compatible Easily integrated on automated equipment for high throughput processing and increased productivity. Same purification process, eliminates additional process validation. Environmentally Friendly Waste is limited to the functional tip. No extra materials, tips, columns, buffers, or reagents required to purify PCR product. No Bind-Wash-Elute Steps Eliminates use of large amounts of reagents and time-consuming, tedious protocols. Catalog Number Seamless Workflow Uses standard pipettor so no changes are needed to your current lab workflows. RapidTip2 is optimized to purify a 50ul PCR sample volume. Product (Compatible with universal pipettes) RR050-048 Diffinity RapidTip2 (48) for PCR Purification w/Polymerase Removal RR050-096 Diffinity RapidTip2 (96) for PCR Purification w/Polymerase Removal Catalog Number Product (Compatible with Rainin LTS® pipettes) RR050-048L Diffinity RapidTip2 (48) for PCR Purification w/Polymerase Removal RR050-096L Diffinity RapidTip2 (96) for PCR Purification w/Polymerase Removal Automated Solutions Diffinity RapidTips for automated solutions are for labs seeking a faster, higher throughput process for PCR purification. Using a 96-tip head, you can purify a plate in less than 2 minutes — with no additional reagents, consumables, or accessories needed! Plus — eliminate user error and obtain consistently purified PCR samples at the push of a button. Contact us We will work with you to help program and validate your robot with the Diffinity RapidTip2. Email: info@diffinitygenomics.com www.diffinitygenomics.com | www.chiraltech.com Diffinity Genomics | Chiral Technologies, Inc. • 800 North Five Points Road • West Chester, PA 19380 • 877-362-1812 • www.diffinitygenomics.com © 2015 Chiral Technologies, Inc. All Rights reserved. Diffinity Genomics, Diffinity, and RapidTip are trademarks of Chiral Technologies, Inc. All other names may be trademarks or registered trademarks of their respective owners. Features and Benefits