With compliments Helmut Singer Elektronik www.helmut-singer.de info@helmut-singer.de Introduction 1 0.01 0.001 0.0001 0.0001 The 11867A offers very low insertion loss and linear operation to minimize its effect on low level (< 0 dBm) signals passing through it. A typical application is shown in Figure 2; the input mixer of a spectrum analyzer is protected from inadvertent overload due to high level signals from an antenna. RF input RF output Max. Max. continuous pulse 0.1 0.001 0.01 0.1 1 10 100 Input power (watts) Figure 3. Typical output power vs input power; T = 25 °C 0 0.25 0.50 Specification limit 0.75 1.00 1.25 0 0.50 1.00 1.5 2.0 2.5 3.0 Frequency (GHz) Figure 4. Typical insertion loss vs frequency Specifications Specifications describe the instrument’s warranted performance over the temperature range 0 to 55 °C (except where noted). Supplemental characteristics are intended to provide information useful in applying the instrument by giving typical, but non-warranted, performance parameters. These are denoted as “typical,” “nominal,” or “approximately.” Frequency range: Insertion loss: Frequency response (flatness): Figure 1. RF limiter DC to 1800 MHz < 0.75 dB < ±0.25 dB Note: For operation to 2.4 GHz, see typical response shown in Figure 4. Description The Agilent 11867A RF limiter is a general purpose diode limiter designed to provide input protection for a variety of instruments. For example, the input circuitry of spectrum analyzers, frequency counters or amplifiers can be protected from unintentional inputs as high as 100 watts peak or 10 watts average power. At even greater power levels, failure mode for the limiter is either an open circuit or a short circuit to ground, thereby protecting the instrument from damage. Impedance: Reflection coefficient: Maximum input power levels: Continuous: Pulse: Limiting threshold: RF input connector: RF output connector: Antenna Limiter 50 ohms, nominal < 0.1 (1.2 SWR) 10 watts average (+40 dBm) 100 watts peak, pulse width ≤ 1 µsec, 0.001 duty cycle 1 mW (0 dBm) typical type N female type N male Note: Device limited to unilateral operation; i.e., input and output are not interchangeable. Weight: Net 0.09 kg (3 oz); shipping 0.45 kg (1 lb) Spectrum analyzer Figure 2. Typical application Insertion loss (dB) Output power (watts) fon +49 241 155 315 fax +49 241 152 066 Agilent Feldchen 16-24 D-52070 Aachen Germany 11867 A RF Limiter, DC to 1800 MHz Data Sheet 60 (2.38) 21 (0.81) For more information, please visit our Web site at: www.agilent.com/find/assist Note: Dimensions are in millimeters (and inches). Figure 5. Dimensions or call 800 829 4444 Product specifications and descriptions in this document are subject to change without notice. © Agilent Technologies, Inc., 2005, 2004, 1979 Printed in USA, March 28, 2005 5952-9295