Prewired Connectors

advertisement
Prewired
Connectors
Introducing Faster, More Reliable
Connections for Prewired Raceway Systems
ew
Prewired
Connectors
from
Wiremold/Legrand, offer the fastest,
most reliable connectivity solution
available for prewired raceway system
installations. Independent testing has shown
that when using new Prewired Connectors in
prewired raceway installations, installers can
get off the job up to eighteen times faster than
when using conventional installation
methods…while virtually eliminating any
callbacks for wiring errors.
The new Prewired Connectors from
Wiremold/Legrand are an ideal choice for large
repetitive, prewired installations such as in
classrooms, offices, dormitories, hotels,
laboratories, and healthcare facilities.
N
Prewired Connectors provide
fast and reliable connectivity
and are available in 3-, 6- and
8-wire configurations.
Features & Benefits
n Prewired connectors. Eliminate miswiring, troubleshooting,
time-consuming backtracking, and expensive callbacks.
n Factory tested and wired components. Ensures correct
wiring each and every time. Provides confidence and
performance reliability for every installation.
n Ultra fast installations. Each Prewired Connector takes
less than five seconds to install vs. traditional six-wire
installations that can require as much as three minutes to
install including wire stripping and attachment of twist-on
wire connectors.
n Rated for applications up to 250V, 30A. Suitable for use
in labs, healthcare facilities, offices, and classrooms. Meets
the needs of most installations while accommodating
future growth.
n Compatible with most raceways. Available in a wide range
of raceway profiles to fit a variety of installation needs (See
the chart on page 2).
n Made in the USA. Assembled and tested by skilled wiring
professionals to meet your specific job specifications.
n UL & cUL Listed multioutlet assemblies. File E15191.
ED1587 – March 2009 – For latest specs visit www.wiremold.com
Prewired Connectors Technical Specifications
Prewired Connector Applications:
Current Rating:
Voltage Rating:
Wire Gauge:
Wire Type:
30A maximum
250V maximum
10AWG maximum
Stranded Copper
3-Wire
6-Wire
8-Wire
NUMBER OF CONNECTORIZED CIRCUITS
Raceway
Systems
3 Wire
Connector
No Shared
Ground or
Neutral
6 Wire
Connector
No Shared
Ground or
Neutral
8 Wire
Connector
Shared Ground/ Shared Ground/
Separate
Shared
Neutral
Neutral
No Shared
Ground or
Neutral
Total Number
of Circuits
Shared Ground/ Shared Ground/
Separate
Shared
Neutral
Neutral
Number of
Ground or
Neutral
Shared Ground/ Shared Ground/
Separate
Shared
Neutral
Neutral
AL3000
1
2
2
3
2
3
5
4
5
8
AL4000
1
2
2
3
2
3
5
4
5
8
AL4320
1
2
2
3
2
3
5
4
5
8
AL4400
1
2
2
3
2
3
5
4
5
8
AL4520
1
2
2
3
2
3
5
4
5
8
AL4750
1
2
2
3
-
-
-
3
3
4
AL7320
1
2
2
3
2
3
5
4
5
8
AL7450
1
2
2
3
2
3
5
4
5
8
ALA3800
1
2
2
3
2
3
5
4
5
8
ALA4800
1
2
2
3
2
3
5
4
5
8
DS4000
1
2
2
3
2
3
5
4
5
8
ALDS4000
1
2
2
3
2
3
5
4
5
8
4000 w/Divider
(Per Channel)"
1
2
2
3
-
-
-
3
3
4
4000
1
2
2
3
2
3
5
4
5
8
5400
1
2
2
3
-
-
-
3
3
4
5500
1
2
2
3
-
-
-
3
3
4
6000
1
2
2
3
2
3
5
5
6
9
NOTE: Do not include special devices in circuit count when fed at device. (not going through connectors)
Currently supports the following NEMA configurations:
5-15R
5-20R
5-30R
L5-15R
L5-20R
L5-30R
6-15R
6-20R
6-30R
L6-15R
L6-20R
L6-30R
NOTE: Consult factory for other configurations.
Specification Guidelines:
•
•
•
•
Maximum of one (1) device per foot of raceway.
Harnesses from multiple feeds may not cross in duct when feeding from different directions.
Maximum base segment length of ten (10) feet.
No downstream protection on GFCI or Surge devices.
Wiremold / Legrand
U.S. and International:
60 Woodlawn Street • West Hartford, CT 06110
1-800-621-0049 • FAX 860-232-2062 • Outside U.S. 860-233-6251
Canada:
570 Applewood Crescent • Vaughan, Ontario L4K 4B4
1-800-723-5175 • FAX 905-738-9721
© Copyright 2009 Wiremold / Legrand All Rights Reserved
ED1587 – March 2009 – For latest specs visit www.wiremold.com