Prewired Connectors Introducing Faster, More Reliable Connections for Prewired Raceway Systems ew Prewired Connectors from Wiremold/Legrand, offer the fastest, most reliable connectivity solution available for prewired raceway system installations. Independent testing has shown that when using new Prewired Connectors in prewired raceway installations, installers can get off the job up to eighteen times faster than when using conventional installation methods…while virtually eliminating any callbacks for wiring errors. The new Prewired Connectors from Wiremold/Legrand are an ideal choice for large repetitive, prewired installations such as in classrooms, offices, dormitories, hotels, laboratories, and healthcare facilities. N Prewired Connectors provide fast and reliable connectivity and are available in 3-, 6- and 8-wire configurations. Features & Benefits n Prewired connectors. Eliminate miswiring, troubleshooting, time-consuming backtracking, and expensive callbacks. n Factory tested and wired components. Ensures correct wiring each and every time. Provides confidence and performance reliability for every installation. n Ultra fast installations. Each Prewired Connector takes less than five seconds to install vs. traditional six-wire installations that can require as much as three minutes to install including wire stripping and attachment of twist-on wire connectors. n Rated for applications up to 250V, 30A. Suitable for use in labs, healthcare facilities, offices, and classrooms. Meets the needs of most installations while accommodating future growth. n Compatible with most raceways. Available in a wide range of raceway profiles to fit a variety of installation needs (See the chart on page 2). n Made in the USA. Assembled and tested by skilled wiring professionals to meet your specific job specifications. n UL & cUL Listed multioutlet assemblies. File E15191. ED1587 – March 2009 – For latest specs visit www.wiremold.com Prewired Connectors Technical Specifications Prewired Connector Applications: Current Rating: Voltage Rating: Wire Gauge: Wire Type: 30A maximum 250V maximum 10AWG maximum Stranded Copper 3-Wire 6-Wire 8-Wire NUMBER OF CONNECTORIZED CIRCUITS Raceway Systems 3 Wire Connector No Shared Ground or Neutral 6 Wire Connector No Shared Ground or Neutral 8 Wire Connector Shared Ground/ Shared Ground/ Separate Shared Neutral Neutral No Shared Ground or Neutral Total Number of Circuits Shared Ground/ Shared Ground/ Separate Shared Neutral Neutral Number of Ground or Neutral Shared Ground/ Shared Ground/ Separate Shared Neutral Neutral AL3000 1 2 2 3 2 3 5 4 5 8 AL4000 1 2 2 3 2 3 5 4 5 8 AL4320 1 2 2 3 2 3 5 4 5 8 AL4400 1 2 2 3 2 3 5 4 5 8 AL4520 1 2 2 3 2 3 5 4 5 8 AL4750 1 2 2 3 - - - 3 3 4 AL7320 1 2 2 3 2 3 5 4 5 8 AL7450 1 2 2 3 2 3 5 4 5 8 ALA3800 1 2 2 3 2 3 5 4 5 8 ALA4800 1 2 2 3 2 3 5 4 5 8 DS4000 1 2 2 3 2 3 5 4 5 8 ALDS4000 1 2 2 3 2 3 5 4 5 8 4000 w/Divider (Per Channel)" 1 2 2 3 - - - 3 3 4 4000 1 2 2 3 2 3 5 4 5 8 5400 1 2 2 3 - - - 3 3 4 5500 1 2 2 3 - - - 3 3 4 6000 1 2 2 3 2 3 5 5 6 9 NOTE: Do not include special devices in circuit count when fed at device. (not going through connectors) Currently supports the following NEMA configurations: 5-15R 5-20R 5-30R L5-15R L5-20R L5-30R 6-15R 6-20R 6-30R L6-15R L6-20R L6-30R NOTE: Consult factory for other configurations. Specification Guidelines: • • • • Maximum of one (1) device per foot of raceway. Harnesses from multiple feeds may not cross in duct when feeding from different directions. Maximum base segment length of ten (10) feet. No downstream protection on GFCI or Surge devices. Wiremold / Legrand U.S. and International: 60 Woodlawn Street • West Hartford, CT 06110 1-800-621-0049 • FAX 860-232-2062 • Outside U.S. 860-233-6251 Canada: 570 Applewood Crescent • Vaughan, Ontario L4K 4B4 1-800-723-5175 • FAX 905-738-9721 © Copyright 2009 Wiremold / Legrand All Rights Reserved ED1587 – March 2009 – For latest specs visit www.wiremold.com