Ballasts Used With Grouse-Hinds Luminaires Watts £ S| High Pressure Sodium Data «- type R/HX/CWA Starting Current Operating Current Input Watts Kit Cat No. 35 J576 120 R-HPF 0.8 0.4 46 CHRBS 035 /120 50 J568 120 120/277 220/240-50 Hz R-HPF HX-HPF HX-HPF 1.0 0.7/0.3 0.3/0.3 0.6 0.6/0.3 0.6/0.6 62 66 66 CHRBS 050 /120 CHRBS 050 IDT CHRBS 050 /22050 » J co 120 120/208/240/277 120/277/347 220 420 220/240-SOHz R-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF 0.9 0.8/0.5/0.4/0.4 .8/.4/.S 0.4 0.2 .5/.4 0.8 0.8/0.5/0.4/0.4 0.8/0.4/0.3 0.4 0.2 .5/.4 86 91 93 91 93 94 CHRBS CHRBS CHRBS CHRBS CHRBS CHRBS 070 070 070 070 070 070 J 120 120/208/240/277 120/277/347 220 480 220/240-50 Hz R-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF 1.5 1 .3/0.8/0.7/0.6 1 .3/0.6/0.5 0.7 0.4 0.5/0.5 1.1 1 .2/0.7/0.6/0.5 1 .2/0.5/0.4 0.6 0.3 0.7/0.6 115 130 130 130 130 130 CHRBS CHRBS CHRBS CHRBS CHRBS CHRBS 100 /120 100 /MT 100 m 100 /220 100 /480 100 /22050 120 120/208/240/277 120/277/347 220 480 220/240-50 Hz R-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF 2.3 2.0/1.2/1.0/0.9 2.0/0.9/0.5 1.1 0.5 0.9/0.8 1.5 1.7/1.0/0.8/0.7 1 .7/0.7/0.6 0.9 0.4 0.9/0.8 170 188 188 188 188 188 CHRBS CHRBS CHRBS CHRBS CHRBS CHRBS 150 /120 150 /MT 150 /TT 150 /220 150 /480 150 /22050 70 100 150 (55V) ,„ /120 /MT ITT /220 /480 /22050 150 (100v) 356 120/208/240/277 480 220/240-50 Hz CWA CWA R-PFC 1 .2/0.7/0.6/.05 0.3 0.9/1.0 1 .8/1 .0/0.9/0.8 0.4 0.9/0.8 188 188 175 CHRBS 150 /MTCE CHRBS 150 /480CE CHRBS 150 /22050CE 200 !366 12-/208/240/277 480 CWA CWA 1 .4/0.8/0.7/0.6 0.4 2.4/1 .4/1 .2/1 .0 0.6 250 250 CHRBS 200 /MT CHRBS /200 /480 120 120/208/240/277 120/277/347 480 230-50 Hz CWA CWA CWA CWA CWA CWA 1.7 1 .7/1 .0/0.8/0.7 1 .7/0.7/0.6 0.9 0.4 1.0 2.5 2.5/1.5/1.3/1.1 2.7/1 .2/0.9 1.5 0.7 1.4 295 295 295 295 310 300 CHRBS CHRBS CHRBS CHRBS CHRBS CHRBS 250 /120 250 /MT 250 /TT 250 /220 250 /480 250 /22050 400 120 120/208/240/277 120/277/347 220 480 230-50 Hz CWA CWA CWA CWA CWA CWA 33 3.3/1 .8/1 .5/1 .4 3.3/1 .4/1 .0 1.6 0.8 1.9 3.8 3.8/2.2/1 .9/1 .7 3.8/1 .7/1 .3 2.1 1.0 2.0 457 464 464 457 464 465 CHRBS CHRBS CHRBS CHRBS CHRBS CHRBS 400 /120 400 /MT 400 /TT 400 /220 400 /480 400 /22050 1000 120/208/240/277 120/277/347 220 480 220/240-50 Hz CWA CWA CWA CWA CWA 6.4/3.8/3.2/2.8 6.4/2.8/2.2 3.6 1.6 6.0/5.6 9.5/5.5/4.8/4.2 9.5/4.2/3.3 5.0 2.3 5.2/4.8 1100 1100 1100 1100 1100 CHRBS CHRBS CHRBS CHRBS CHRBS 1000 /MT 1000 /TT 1000 /220 1000 /480 1000 /22050 250 674 ,_„ !iSU 352 220 Copyright 2002 Cooper Industries, Inc. COOPER Grouse-Hinds Industrial Lighting Table of Contents Section L of the Grouse-Hinds Catalog contains information on industrial lighting. Product details on individual luminaires are given in eleven separate sections, as noted below. In addition, a complete section (7L) is devoted to luminaire hangers and accessories. Considerations for Selection Section 3L High Intensity Discharge (H.I.D.) LightingEnclosed and Gasketed (for use in hazardous [classified] locations, non-hazardous locations, and marine locations) Preceding the eleven product sections is a Selector Guide. Included in this section is information on: • a selection of the appropriate light source for a given application • a Quick Selector Guide of the luminaires that are designed and approved to meet the various environmental requirements of the National Electric Code • determining the proper size (i.e., wattage) and number of units to achieve the desired light levels in a given application • methods to follow in making a luminaire layout. Cat. Nos. are shown, in many cases, for complete assemblies including mounting, reflector, globe, and guard, as well as individual components. In these cases, ordering can be done by component or by complete assembly. Photometric and other technical data is included in each section for the luminaires it contains. Information relating to product families in the Lighting Section is shown as follows: Indoor and outdoor vaportight luminaires for use in applications where dirt, moisture, and corrosion problems exist. Included are units with integral ballasts. DMV Champ" Series LMV Champ" Series VMV Champ" Series N2MV Champ* Series Section 1L Incandescent Lighting— Enclosed and Gasketed (for use in hazardous [classified] locations and non-hazardous locations) (for use in non-hazardous areas; some luminaires have specific hazardous [classified] locations suitability.) Indoor and outdoor vaportight luminaires and accessories for use in industrial applications where dirt, moisture, and corrosion problems exist. NDA Corro'Gard' Series V160 V Series Vaporgard™ Series Section 2L Incandescent Lighting (for use in hazardous [classified] locations) Indoor and outdoor luminaires and accessories EV Series COOPER Grouse-Hinds Section 4L High Intensity Discharge (H.I.D.) Lighting (for use in hazardous [classified] locations) Indoor and outdoor luminaires and accessories. Included are luminaires with integral ballasts. Hazard'Garif Series Lo'Pro Hazard-Card" Series Section 5L Fluorescent Lighting Indoor and outdoor fluorescent luminaires and accessories for application in all classes of hazardous and non-hazardous locations. For hazardous For non-hazardous locations locations CPMVF EVF, EVFDR NFL FVN VF Vaporgard Series FVS EVFT DMVF N2MVF EVLPF VF, ELLK Section 6L Floodlights (for use in hazardous [classified] locations and non-hazardous locations) CPMV EVMA-S812 HazardGard' Series FMV Champ" Series F2MV FZD FMV1000 RCDE Copyright 2002 Cooper Industries, Inc. Section 7L Luminaire Hangers and Accessories (for use in hazardous [classified] locations and non-hazardous locations) A variety of luminaire hangers for use with the luminaires listed. Information on mounting accessories required and typical luminaire weights also included. For hazardous For non-hazardous locations locations EAHC, EFHC AL EC AHG EFH ARB QUA, GUF FHM UNR UNE, UNH, UNHC CPS UNJ UNJC Section 8L Portable Lighting A variety of portable luminaires for hazardous and non-hazardous applications. VS EVH RCDER EVP Section 9L Emergency Lighting (for use in hazardous [classified] locations) • Emergency lighting for use in power outage situations. Also, exit signs and strobe warning lights. N2LPS Light-Pak™ Series CPMVFB EXL-exit sign DMVFB ELPS Light-Pak™ Series N2MVFB EVLPFB Section 10L Beacons and Strobes Indoor and outdoor luminaires for use in applications where visual signaling is a requirement. For hazardous locations EV Beacons and Strobes VF Beacons VDAS Strobes Section 11L Specialty Lighting Luminaires for use in applications where conventional lighting is not acceptable due to size and/or location, such as tank, instrument, and gauge applications. For hazardous For non-hazardous locations locations EV - tank lights V Observation EVIL ELG - gauge light 659