Time Switches – 24 Hour Dial T100 Series – Designed for industrial, commercial and residential applications. Highest HP ratings in the industry for loads up to 40 amps, providing direct 24 hr. control of most loads. Provides 1 to 12 “ON/OFF” operations each day with minimum ON/OFF times of 1 hour. All models equipped with one “ON” and one “OFF” tripper. Applications • Indoor/Outdoor Lighting • Hydrochlorinators • Heating/Ventilating Systems • Post Lanterns • Air Conditioning • Music and Signal Systems • Signs • Blowers • Fans • Pool Heaters • Electric Fences • Poultry Foggers • Filters • Pumps • Conveyers Specifications Case – Drawn steel 7-3/4" (19.7 cm) H, 5" (12.7 cm) W, 3" (7.6 cm) D in gray finish. Spring hasp, with hole for lock, holds permanently attached, side hinged door closed. Three mounting holes on back plus handy box mounting holes. Knockouts – Combination 1/2"–3/4" nominal knockouts, one on back and each side of case and two on bottom. Optional Enclosures – See Time Switch Cases page for optional enclosures. Special Voltages and Cycles – See Time Switch Motors page for available motors. Switch Rating – Each Pole; 40 Amp Resistive, 120-480 VAC; 40 Amp Tungsten, inductive or 1000 VA pilot duty, 120-277 VAC; 2 HP (24 FLA) 120 VAC; 5 HP (28 FLA) 240 VAC single phase; 7-1/2 HP (28 FLA) 208 VAC three phase; 10 HP (28 FLA) 240 VAC three phase. Model # Model # w/See-Thru Cover Model # Plastic Case Switch Clock Motor Volts 60 Hz AMPS (per pole) HP Rating T101 T102 T103 T104 T101B* T105 T106R† T101PCD82 –– T103PCD82 T104PCD82 –– –– –– T101P T102P T103P T104P –– –– –– SPST SPST DPST DPST SPST 1NO / 1NC** 1NO / 1NC** 125 208-277 125 208-277 125 125 208-277 40 40 40 40 40 40 40 2 5 2 5 2 2 5 * Separate clock motor terminals for switching circuits not on line voltage ** Can be wired as SPDT † Only available in NEMA 3R case For additional trippers (1 ON / 1 OFF per pack), order No. 156T1978A C22.2-177 LR3730 UL917 2.75 lbs 1.25 kg 24 Hr. w/Skipper, Optional Carryover -40°F (-40°C) to 130°F (54°C) T170 Series – Same features as the T100 Series plus a skipper option to omit operation on selected days. Cutout screws are inserted in the dial for days which operation is to be skipped. Provides up to 10 ON/OFF operations each day with min. ON/OFF operations of 1 hour and max. ON time of 20 hours. Includes one CUTOUT tripper (also serves as an “ON” tripper), one “OFF” tripper and three skipping screws. T170CR Series – Same features as the T170 Series Skipper models plus a min. of 16 hours carryover for maintaining preset schedules during power failures. Carryover automatically rewinds when power resumes; only one hour of rewinding time required for every two hours of power outage. 4PST models are ideal for 3-phase load control. Specifications Case – T170 Series same as T100 except as noted under Optional Enclosures. T170CR only in NEMA 3R drawn steel 9-3/8" (23.8 cm) H, 5-1/2" (14.0 cm) W, 3-5/8" (9.2 cm) D in gray finish. Hasp, with hole for lock, holds permanently attached, side-hinged door closed. Bracket plus two holes on back below switch for mounting. Separate grounding terminal. Optional Enclosures – 4 pole and 2 NO/ 2 NC models not available in standard or plastic case; only in NEMA 3R steel case. T170CR only available in steel NEMA 3R enclosure. Special Voltages and Cycles – See Time Switch Motors for available motors. Contact factory for availability of time switch with 50 cycle or other voltages. Special Voltages and Cycles – Same as T100 Series. Switch Rating – Same as T100 Series. C22.2-177 LR3730 UL916 -40°F (-40°C) to 130°F (54°C) 2.75 lbs 1.25 kg Same as T100 Series Model # Switch Clock Motor Volts 60 Hz AMPS (per pole) HP Rating T171 T172 T173 T174 T175 T176 T1471BR* T1472BR* T1475BR* T1871BR* T171CR T173CR T174CR T1471BCR* SPST SPST DPST DPST 1NO / 1NC** 1NO / 1NC** 4PST 4PST 4PST 2NO / 2NC*** SPST DPST DPST 4PST 125 208-277 125 208-277 125 208-277 125 208-277 480 125 125 125 208-277 125 40 40 40 40 40 40 40 40 40 40 40 40 40 40 2 5 2 5 2 5 2 5 5 2 2 2 5 2 * Separate clock motor terminals for switching circuits not on line voltage. ** Can be wired as SPDT For additional trippers (1 ON / 1 OFF / 1 CUTOUT per pack), order No. 156T1948A For additional skipper screws (3 skipper screws per pack), order No. 156T3085A 74 www.intermatic.com ***Can be wired as DPDT Time Switches Portable This portable cord connected time switch performs all the functions of the T100 and T170 series time switches plus it is completely portable eliminating the need for wiring. Supplied complete with 6' grounded cord set and receptacle installed. Applications (Indoor Only) • Photo Copiers • Electric Water Heaters • Ventilating Systems • Portable Lights • Air Conditioning • Motors • Signs • Fans • Pumps • Space Heaters • Poultry Foggers • Blowers Specifications Case – Drawn steel 7-3/4" (19.7 cm) High, 5" (12.7 cm) Wide, 3" (7.6 cm) Deep in gray finish. Spring hasp, with hole for lock, holds permanently attached, side hinged door closed. Three mounting holes on back plus handy box mounting holes. Knockouts – Not applicable; prewired cord and receptacle. Switch Rating – 15 Amp Resistive, 15 Amp Tungsten; 345 VA pilot duty (15 FLA), 125 VAC. Model # Switch Clock Motor Volts 60 Hz Amps (per pole) Skipper Wheel P171-30 SPST 125 15 Yes G For additional trippers Model Series P170 (1 ON / 1 OFF / 1 CUTOUT per pack), order No. 156T1948A W 120V - 15A Receptacle C22.2-177 LR3730 UL917 3 lbs 1.36 kg -40°F (-40°C) to 130°F (54°C) C22.2-177 LR3730 UL917 2.75 lbs 1.25 kg -40°F (-40°C) to 130°F (54°C) 24 Hour Dial w/Skipper The T1900 Supervisor Series provides up to 96 operations (48 ON / 48 OFF) every 24 hours. This series provides operations with minimum ON / OFF times of 15 minutes. Trippers slide in and out of dial for fast accurate setting. The skipper models provide for operations to be omitted on selected day(s) of the week. Model with carryover provides a minimum of 16 hours of carryover to maintain preset schedules within +/- 2% accuracy during power failures. The carryover automatically rewinds when power resumes. Only one hour is required to rewind the carryover for each two hours of power outage. Applications • Oil Well Pumps • Filters • Blowers • Poultry Feeders • Heaters • Heaters • Process Equipment • Recorded Music • Dairy Equipment • Fans • Silo Unloaders • Poultry Foggers Specifications Case – Drawn steel 7-3/4" (19.7 cm) High, 5" (12.7 cm) Wide, 3" (7.6 cm) Deep in gray finish. Spring hasp, with hole for lock, holds permanently attached, side hinged door closed. Three mounting holes on back plus handy box mounting holes. Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case and two on bottom. Optional Enclosures – See Time Switch Cases for optional enclosures. Special Voltages and Cycles – See Time Switch Motors for available motors. Switch Rating – 20 Amp maximum 125, 208-277 and 480 VAC; 1/2 HP , 125 VAC; 1 HP, 250 VAC Power Input – 5 Watts maximum. Model # Switch Clock Motor Volts 60 Hz Spring Wound Carryover Amps Skipper Wheel T1905* T1906 T1975 T1976* T1975E* SPDT SPDT SPDT SPDT SPDT 125 208-277 125 208-277 480 No No No No No 20 20 20 20 20 No No Yes Yes Yes For additional trippers (12 per pack), order No. 156T1950A *Add “R” suffix for NEMA 3R steel case Replacement Snap Switch 133T701A www.intermatic.com 75 Time Switches Short Range Cycle Timer Short Range Cycle Timers provide repeat cycling for “ON” times. Ten combination “ON/OFF” trippers supplied with each switch. Applications • Ventilating Fans • Fogging Equipment • Process Equipment • Spraying Equipment • Poultry Feeders • Livestock Feeders • Pumps • Poultry Fans • Bulk Milk Coolers Specifications Case – Same as T100 Series. Knockouts – Same as T100 Series. Optional Enclosures – Same as T100 Series. Switch Rating – 20 Amp Resistive 125, 208-277 VAC; 1/2 HP, 125 VAC; 1 HP, 250 VAC C22.2-177 LR3730 UL917 2.75 lbs 1.25 kg -40°F (-40°C) to 130°F (54°C) Model # Switch Clock Motor Volts 60 Hz Dial Cycle Tripper Actuating Time Amps C8855 C8815 C8835 C8865 C8825 C8845 C8866 SPDT SPDT SPDT SPDT SPDT SPDT SPDT 125 125 125 125 125 125 250 5 Min. 10 Min. 30 Min. 1 Hr. 2 Hr. 4 Hr. 1 Hr. 2.5 Sec. 5 Sec. 15 Sec. 30 Sec. 60 Sec. 120 Sec. 30 Sec. 20 20 20 20 20 20 20 Note: The life of the switch contacts is affected by the size and type of the controlled load. The expected minimum life at 20 amps (resistive) load is 100,000 cycles Replacement Snap Switch 133T773A For additional trippers (12 trippers per pack), order No. 156T1950A See Solid State Cycle Percentage Timer Sprinkler/Irrigation Timer with 14-Day Skipper These irrigation timers permit 1 to 60 “ON” operations every 24 hours. This series is designed for water metering in increments of 12 minutes to 20 hours - 45 minutes for maximum conservation of precious water resources. The 14-day skipper feature permits irrigation to be omitted on selected day(s) and also provides for “every other” day operation. The “ON/OFF/AUTOMATIC” switch allows shutdown during rainy days or extended watering during dry periods without disturbing the automatic cycle set on dial. Applications • Multi-Station Hydro Indexing Valves • Irrigation Control • Greenhouses • Feeders • Lawn Sprinkling • Drip Irrigation Systems • Pumps Specifications Case – Plastic NEMA 3R case. Cases include hanging bracket plus two mounting holes on back below switch for mounting. Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case, and two on bottom. Switch Rating – T8805P101C – 15 Amps, 125 VAC, 1/2 HP, SPST. R8806P101C – 25 Amps, 208-277 VAC, 2 HP, DPST relay. R8815P101C – 25 Amps, 120 VAC, 1-1/2 HP, DPST relay. R8816P101C – 25 Amps, 208-277 VAC, 3 HP, DPST relay. T8845PV – 125 VAC, SPST, output 24 Volts - 20VA C22.2-177 LR3730 UL917 76 3.75 lbs 1.7 kg -40°F (-40°C) to 130°F (54°C) Model # Switch Motor Voltage 60 Hz Output Voltage 60 Hz AMPS (per pole) HP Rating T8805P101C R8806P101C R8815P101C* R8816P101C* T8845PV** SPST DPST DPST DPST SPST 125 208-277 120 208-277 125 –– — — –– 24 15 25 25 25 20VA 1/2 2 1-1/2 3 –– * Includes rain sensor input terminals- rain sensor not supplied ** Includes 24 volt - 20 VA transformer For additional trippers (12 per pack), order No. 156T1950A www.intermatic.com Time Switches Timing Control Center, 7-Day Dial with Carryover This series provides photo control initiated / time switch terminated control. These time switches provide a different “ON/OFF” program each day of the week and a spring wound carryover. These time switches are recommended for applications where you need to turn a load “ON” at dusk and “OFF” at a preset time. The spring wound carryover provides a carryover of 16 hours minimum to maintain accurate load control even during power failure. When power resumes, the carryover automatically rewinds itself. Only 1 hour is required to rewind the carryover for each 2 hours of outage. The three models provide control of 1,2 or 3 circuits. A light level adjustment is provided on the photo control. All models have single pole double throw switches and manual circuit by-pass switches. Unit is designed to control the contactor control circuit only. It is not recommended for direct switching of tungsten, mercury vapor or similar loads. Applications • Parking Lot Lighting • Storefront Lighting • Landscape Lighting • Stairway Lighting • Billboard Lighting • Car Lot Lighting • Entryway Lighting • Security Lighting Specifications Case – Steel in gray finish 12-1/2" (31.7 cm) high, 8-1/4" (21.0 cm) wide, 4" (10.2 cm) deep. Indoor type with toggle action drawbolt and locking feature. Four mounting holes on back. Separate grounding terminal. Knockouts – Combination 1/2"-3/4" nominal knockouts, two on back one on each side and two on bottom. Also one 1" nominal on bottom center. Optional Enclosures – None available. Contact Rating – 15 Amp, 1/2 HP, 125/250 VAC; 420 VA pilot duty; 150 Watts Tungsten, 125 VAC (May also be used with 24 volt systems if wired in accordance with National Electric Code Regulations.) Model # Description Clock Motor Volts 60 Hz T51211BC Circuit A Circuit B Circuit A Circuit B Circuit C 120 — 120 — — T51311BC - Sunset, Photo Control ON - Preset Time Switch OFF Sunset, Photo Control ON - Sunrise, Photo Control OFF Sunset, Photo Control ON - Preset Time Switch OFF Sunset, Photo Control ON - Sunrise, Photo Control OFF Preset Time Switch ON - Preset Time Switch OFF All models have separate clock motor terminals for switching circuits not on line voltage For additional trippers (7 ON / 7 Off per pack), order No. 156T2548A See Next Generation Electronic Time Switches with Astro Feature C22.2-177 LR3730 UL917 10.5 lbs 4.8 kg -40°F (-40°C) to 130°F (54°C) C22.2-177 LR3730 UL917 2.75 lbs 1.25 kg -40°F (-40°C) to 130°F (54°C) Compact, 7-Day The T2000 Series provides up to 84 (42 “ON/OFF”) operations each week. Minimum “ON/OFF” times for this series are 2 hours each providing up to 6 “ON/OFF” operations each day. Applications • Heating • Lights • Air Conditioning • Pumps • Ventilating • Motors • Defrost Control • Fans Specifications Case – Drawn steel 7-3/4" (19.7 cm) high, 5" (12.7 cm) wide, 3" (7.6 cm) deep in gray finish. Spring hasp, with hole for lock, holds permanently attached, side hinged door closed. Three mounting holes on back plus handy box mounting holes. Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case and two on bottom. Optional Enclosures – See Time Switch Cases for optional enclosures. Special Voltages and Cycles – See Time Switch Motors for available motors. Switch Rating – 20 Amp Resistive, 125 and 208-277 VAC; 1/2 HP 125 VAC; 1 HP 250 VAC Model # Switch Clock Motor Volts 60 Hz Amps T2005 T2006 SPDT SPDT 125 208-277 20 20 For additional trippers (12 per pack), order No. 156T1950A Replacement Snap Switch 133T701A www.intermatic.com 77 Time Switches 7-Day Dial With & Without Carryover These time switches provide a different “ON/OFF” program each day of the week. They also provide for 4 pole single throw and 4 pole (2NO/2NC) switching. This series provides true 7-day load control with minimum ON and minimum OFF times of 3-1/2 hours. The “BC” models with carryover provide a carryover of 16 hours minimum to maintain accurate load control even during power failure. When power resumes, the carryover automatically rewinds itself. Only 1 hour is required to rewind the carryover for each 2 hours of outage. Applications • Heating • Outdoor Lighting • Ventilating Systems • Air Conditioning • Motors • Fans • Pumps • Signs • Filters • Indoor Lighting • Billboards • 3 Phase Loads Specifications C22.2-177 LR3730 UL917 Models without carryover 8 lbs 3.6 kg Models with carryover 9 lbs 4.1 kg Case – Steel in gray finish 12-1/2" (31.7 cm) high, 8-1/4" (21.0 cm) wide, 4" (10.2 cm) deep. Indoor type with toggle action drawbolt and locking feature. Four mounting holes on back. Separate grounding terminal. Knockouts – Combination 1/2"-3/4" nominal knockouts, two on back one on each side and two on bottom. Also one 1" nominal on bottom center. Optional Enclosures – See Time Switch Cases for optional enclosures. Special Voltages and Cycles – See Time Switch Motors for available motors. Contact factory for availability of time switch with 50 cycle or other voltages. Switch Rating – Each Pole 40 amp resistive, 120-480 VAC; 40 amp tungsten, inductive or 1000 VA pilot duty, 120-277 VAC; 2 HP (24 FLA) 120 VAC; 5 HP (28 FLA) 240 VAC single phase; 7-1/2 HP (28 FLA) 208 VAC three phase; 10 HP (28 FLA) 240 VAC three phase. Carryover – Minimum time - mechanical operation: 16 hours. Carryover accuracy +/-2%. -40°F (-40°C) to 130°F (54°C) Model l# Model with CarryOver Switch Clock Motor Volts 60 Hz Amps (per pole) T7401B T7402B T7801B T7802B T7401BC T7402BC T7801BC T7802BC 4PST 4PST 2NO/2NC 2NO/2NC 125 208-277 125 208-277 40 40 40 40 * All models (B or BC suffix) have separate clock motor terminals.for switching circuits not on line voltage For additional trippers (7 ON / 7 OFF per pack), order No. 156T2548A Astro Dial With Skipper & Carryover This time switch self adjusts for seasonal changes. The astronomic dial; automatically adjusts itself as the days grow shorter or longer. A skipper provides lighting control to be omitted on selected day(s) of the week. The carryover is designed to maintain preset schedule during power outages for a minimum of 16 hours. Only 1 hour is required to rewind the carryover for each 2 hours of outage. The 3PST switch configuration provides for control of 3-phase lighting. Three skipper screws are furnished. Lighting Applications • Parking Lots • Entryways • Landscape Lights • Security • Stairways • Storefronts • Billboards • Car Lots Specifications Case – NEMA 3R drawn steel 11-1/2" (29.2 cm) high, 8-1/4" (20.9 cm) wide, 4-1/2" (11.4 cm) deep in gray finish. Hasp, with hole for lock, holds permanently attached, side hinged door closed. Mounting bracket plus two holes below switch on back for mounting. Separate grounding terminal. Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case and two on bottom. Optional Enclosures – None. Switch Rating – Each pole: 40 amp tungsten up to 277 VAC; 1 HP, 120 VAC; 690 VA pilot duty. UL917 E10694 C22.2-177 LR3730 Models V45471CR & V45472CR 9 lbs 4.1 kg Other Models 5 lbs 2.3 kg -40°F (-40°C) to 130°F (54°C) Model # Switch Clcock Motor Volts 60 Hz Amps V45471CR* V45472CR* V45471R V45472R 3PST 3PST 3PST 3PST 125 208-277 125 208-277 40 40 40 40 # Indicate City and State nearest installation when ordering. * Includes spring wound carryover For additional skipper screws (3 skipper screws per pack), order No. 156T1957A See Next Generation Electronic Time Switches with Astro Feature 78 www.intermatic.com Water Heater Time Switches The WH40 provides a convenient external override switch. Utilities in many areas of the country offer two electric rates for residential or commercial customers. One rate has the regular daytime electrical rate, the other is “off peak” rate. The off peak rate provides customers with “lower-priced” electricity during the nighttime and weekend periods. These time switches allow the customer to shift electricity use into these off-peak time periods in an attempt to save utility costs. Applications Water Heater Control for: • Residential • Commercial • Industrial • Institutional / Schools • Military Facilities Specifications Case – Drawn steel 7-3/4" (19.7 cm) High, 5" (12.7 cm) Wide, 3" (7.6 cm) Deep in gray finish. Spring hasp, with hole for lock, holds permanently attached, side hinged door closed. Three mounting holes on back plus handy box mounting holes. Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case and two on bottom. Special Voltages and Cycles – See Time Switch Motors for available motors. Switch Rating – 40 Amp Resistive, Inductive or Tungsten 120-277 VAC; 1000 VA pilot duty 120-277 VAC; 2 HP (24 FLA) 125 VAC; 5 HP (28 FLA) 240 VAC. Model # Switch Clock Supply Volts 60 Hz Watts External Switch Amps/Pole T104-20 WH40 DPST DPST 208-240 250 10000 10000 No Yes 40 40 The "LITTLE GRAY BOX"® For additional trippers (1 ON / 1 OFF per pack), order No. 156T1978A C22.2-177 LR3730 UL917 2.75 lbs 1.25 kg -40°F (-40°C) to 130°F (54°C) Electronic Water Heater Timers These time switches provide automatic control for electric water heaters. They provide to-the-minute accuracy in programming and timekeeping. The time switches can be programmed for repeat daily scheduling, 5-day working week scheduling, weekend scheduling or any individual day scheduling. Timers can be scheduled for operation during the lowest time-of-day rates or to switch off the electric heater during period of utilities peak power usage. The time switch can be set to operate for up to 6 on/off operations daily for a maximum of 42 on/off operations weekly. Both models provide a convenient external override switch and LED load indicator for ease in scheduling hot water as required for extra hot water demands. The timers include a “AA” alkaline battery carryover which protects both timekeeping and program information for a minimum of 3 years. Applications Water Heater Control for: • Residential • Military Facilities • Institutional • Schools • Industrial • Commercial Specifications With Manual External Override and Load Indicator Case – Drawn steel 7-3/4" (19.7 cm) H x 5" (12.7 cm) W x 3" (7.6 cm) D in gray finish. Spring hasp, with hole for lock, holds permanently attached, side hinged door closed. Three mounting holes on back plus handy box mounting holes. Knockouts – Combination 1/2"–3/4" nominal knockouts, one on back and each side of case and two on bottom. Switch Rating – 30 Amp Resistive or Inductive 120-240 VAC; 1 HP, 120 VAC; 1-1/2 HP, 240 VAC; 5 Amps Tungsten, 120/240 VAC. Model # Switch Clock Supply Volts 50/60 Hz Watts External Switch Amps/Pole EH10 EH40 SPST DPST 120 240 3600 7200 Yes Yes 30 30 www.intermatic.com 50/60 Hz Operation UL916 E76987 C22.2-177 LR3730 2.75 lbs 1.25 kg -4°F (-20°C) to 122°F (50°C) 79 Electronic Time Switches 7-Day 1 & 2 Circuit Electronic Time Switches 7 Day ET170C Series 7 Day with momentary output option ET279C (2 Circuit) Certified under Title 24, Part 6, Section 131(D) of the California Code of Regulations 50/60 Hz Operation UL917 C22.2-177 LR3730 2.5 lbs 1.1 kg -40°F (-40°C) to 155°F (68°C) These electronic time switches provide the to-the-minute programming for accurate load control and reduced energy costs. Up to 20 set points or events (10 ON/10 OFF or any combination) can be preset to automatically repeat on a weekly or daily basis. The program can be overridden at any time by placing the selector switch in the Manual position. These time switches provide for true 7-day load control with up to 140 operations (70 ON/70 OFF or any combination) each week. Model ET279C provides 20 operations or momentary contact closures of 1 to 8 seconds (ten each or any combination) for two independent circuits. All models come with a factory installed industrial grade standard “AA” alkaline battery to provide timekeeping and automatic carry-over for a minimum of 3 years. The battery is easily replaced in the field without requiring removal of the time switch mechanism or field wiring. These models can also be used for easy field replacement of the T100 and T170 series mechanical time switches. Just snap out the old mechanism and snap in the new using the existing wiring and case. Specifications Case – Drawn steel 7-3/4" (19.7 cm) High, 5" (12.7 cm) Wide, 3" (7.6 cm) Deep in gray finish. Spring hasp, with hole for lock, holds permanently attached, side hinged door closed. Three mounting holes on back plus handy box mounting holes. EP Models in plastic beige NEMA 3R raintight enclosure; 9-3/8" (23.8 cm) H, 5-1/2" (14.0 cm) W, 3-3/4" (9.5 cm) D. Note: The electronic mechanism snaps into the standard Intermatic time switch case, replacing mechanical mechs, if desired. Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case and two on bottom. Optional Enclosures – See Time Switch Cases for optional enclosures. Special Voltages and Cycles – ALL models 50 or 60 Hz. Switch Rating – Except model ET100C. 30 Amp Inductive/Resistive, 24 / 120 / 240 / 277 VAC 60 Hz; 20 Amp Resistive, 28 VDC; 1 HP 120 VAC 60 Hz; 2 HP 240 VAC 60 Hz; 5 Amp Tungsten, 120 / 240 / VAC 60 Hz; 20 Amp ballast, 120-277 VAC 60 Hz. ET100C same ratings for 120 Volt loads only. Models ET105C and ET175C the normally closed contact ratings are as follows: 10A Resistive/General purpose, 12 - 277VAC; 10A Resistive/General purpose, 28VDC; 3A Ballast, 120 - 277VAC; 1/4 HP, 120 VAC; 1/2 HP, 240 VAC; 30 LRA; 12 FLA; 275 VA pilot duty, 120 - 240 VAC Carry-over – Field replaceable “AA” battery maintains program and accurate timekeeping for 3 years minimum. Up front replacement does not require removal of mechanism or field wiring. Wiring Terminals – #18 to #10 AWG wire. Minimum ON/OFF Times – 1 minute. Maximum ON/OFF Times – 24 Hour models 23 hours 59 minutes, 7-Day models 6 days 23 hours 59 minutes. 24 Hour 24 Hour Electronic Time Switches These time switches provide the same dependable and uncomplicated performance as the T101 mechanical time switch...plus to-the-minute programming for accurate load control and reduced energy costs. Up to 8 set points or events (4 ON/4 OFF) can be preset to automatically repeat on a daily basis. The program can be overridden at any time by placing the selector switch in the Manual position. An industrial grade “AA” Alkaline battery provides 3 years minimum program and timing protection. Applications ET100C Series • Schools • Car Lots • Offices • Restaurants • Airports • Parks • Stores • Apartments • Commercial Ovens • Livestock Feeders • Lighting • Poultry Equipment • Air Conditioners • Process Equipment • Hotels For Controlling: • Water Heaters • Fans/Blowers/Pumps 24 Hour Model # Switch Clock Supply Volts Amps 50/60 Hz (per pole) HP Rating SPST DPST SPST SPST SPST DPST DPST SPDT 120^ 240^ 120 120 120-277 120 120-277 120 *** *** ** *** *** *** *** *** 24 Hour EP100C Series UL917 C22.2-177 LR3730 80 -40°F (-40°C) to 155°F (68°C) EP101CP3^ EP104CP3^ ET100C ET101C ET102C ET103C ET104C ET105C Model # Switch Clock Supply Volts Amps 50/60 Hz (per pole) HP Rating SPST SPST DPST DPST SPDT SPST* 120 120 120 240 120 120 *** *** *** *** *** *** 7 Day 30 30 30 30 30 30 30 30 ET171C ET171CR^^ ET173C ET174C ET175C ET279C^^^ ^ These models in NEMA 3R raintight plastic beige enclosure. 60 Hz only ^^ In NEMA 3R raintight steel enclosure ^^^ Includes field selectable momentary output for bell ringing and latching contractor control * Each circuit for 2 circuits ** 1 @ 120 VAC *** 1 @ 120 VAC 2 @ 240 VAC www.intermatic.com 30 30 30 30 30 30 7-Day Programmable Electronic Time Switches and Lighting Control These electronic time switches provide a keyboard entry system for true 7-day load control. All models provide capability of programming up to 28 set points or events (14 ON/14 OFF or any other combination) which can be set “to-the-minute” any time during the week. The program can be overridden at any time by placing the selector switch in the MAN (Manual) position. A maximum of 196 set points can be programmed each week. All models are equipped with factory installed industrial grade “AA” NiCad rechargeable batteries which provide timekeeping (accurate within .01%) and maintain all programmed set points for a minimum of 24 hours. The batteries are located on the cover of the case providing easy field replacement. The batteries recharge automatically in approximately 8 hours. Batteries have an estimated life in excess of 5 years. These time switches may be used for controlling inductive loads by adding a surge suppressor of the proper voltage across the time switch contacts. See specification note. Model ET716CK is designed for 7-day control of outdoor lighting. It features a low voltage photo sensor (not a photo control) with a light level slide adjustment, to ensure that lights are OFF during daylight hours. A built-in delay prevents the load from switching due to sudden changes in light levels, such as those caused by headlights or lightning. Applications • Schools • Restaurants ET700C Series • Offices • Parks • Airports • Apartments • Stores • Hospitals • Hotels • Factories • Car Lots • Farms For Controlling: • Water Heaters • Process Equipment • Bells and Signals • Commercial Ovens • Lighting • Fans/Blowers/Pumps • Livestock Feeders • Heating/Ventilating Equipment • Air Conditioners • Poultry Equipment Certified under Title 24, Part 6, Section 131(D) of the California Code of Regulations Applications (Model ET716CK) • Outdoor Parking Lot Lighting • Car Lot Lighting • Billboard Lighting • Security Lighting UL916 E76987 • Landscape Lighting • Area Lighting C22.2-177 LR3730 2.7 lbs 1.2 kg Specifications -40°F (-40°C) to 150°F (65°C) Case – Drawn steel 7-3/4" (19.7 cm) high, 5" (12.7 cm) wide, 3" (7.6 cm) deep in gray finish. Spring hasp, with hole for lock, holds permanently attached, side hinged door closed. Three mounting holes on back plus handy box mounting holes. Note: The electronic mechanism snaps into the standard Intermatic time switch case, replacing mechanical mechs, if desired. Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case and two on bottom. Optional Enclosures – See Time Switch Cases for optional enclosures. Switch Rating – UL Listed Rating – 1 mA-5 amp resistive, 24/120/240 VAC 60 Hz; 75 VA pilot duty, 24 VAC, 60 Hz; 125 VA pilot duty, 120/240 VAC, 60 Hz CSA Certified Switch Rating – 1 mA-5 amp resistive, 24/120/240 VAC 60 Hz; 75 VA pilot duty, 24 VAC, 60 Hz; 120 VA pilot duty, 120/240 VAC, 60 Hz. Switch Rating (ET716CK) – Each Pole; 60 Hz unless noted. 1 mA- 5 amp resistive, 24 / 120 / 240 /277 VAC; 75 VA pilot duty, 24 VAC; 125 VA pilot duty, 120, 240 VAC; 480 VA pilot duty, 277 VAC; 2.16 amp inductive, 24, 120, 240, 277 VAC NO contacts; 0.85 amp inductive, 24, 120, 240, 277 VAC NC contacts Operating Temperature Range – Battery capacity and charge acceptance will be less than nominal outside of -4°F (-20°C) to 104° (40°C). Note: For controlling inductive loads a surge suppressor must be installed across the time switch contacts. Failure to do so may result in erratic timer operation. Order surge suppressors as follows; 176ET8A for 24 volt AC nominal loads, 176ET9A for 120 volt AC nominal loads, 176ET10A for 240 volt AC nominal loads. Model # Switch Clock Supply Volts 60 Hz Amps (per pole) ET715C ET718C ET799C ET716CK SPDT 4PDT 2PST** DPDT 120 120 120 120/240/277 (Field Selectable) 5 5 5 5 ET700CK Series ** With momentary contacts To order special cases see Optional Enclosures UL916 E76987 www.intermatic.com C22.2-177 LR3730 2.7 lbs 1.2 kg -40°F (-40°C) to 150°F (65°C) 81 Next Generation Electronic Time Switches These electronic time switches provide to-the-minute programming for 7-day or full year load control and reduced energy costs. A user selectable clock format for 12 hour AM/PM or 24 hour is provided for programming a minimum of 1,000 set points. Each ON and OFF switching function uses a set point. Full year control features include up to 99 different “holidays” each of which can be programmed for any duration. Any holiday or holiday duration can be left for “no load activity” or programmed for a unique load activity. Fully automatic daylight saving time adjustment, with user selectable override, and automatic leap year adjustment are also standard on the ET70000C series. Weekly programming provides single step weekday and weekend programming to simplify typical 5/2 day load control. An automatic review feature enables quick easy review of all programmed data. Flexible load control is enhanced by Astro, Pulse (from 1 to 127 seconds) and Interval options as required for outdoor lighting control, bell ringing and after hours temporary override respectively. These options can be combined, for example, to provide Astro switching with a Pulse output for outdoor lighting using a latching contactor. For model ET70415CR the Interval option provides the ability to program all 4 loads independently for override times (up to 6 days, 23 hours, 59 minutes). The loads can be independently overridden using a remote (up to 1,000 feet) momentary or maintained switch connected to the time switch with bell wire. Each load in the two and four circuit models may be programmed independently, together or in groups. A non-volatile memory maintains all programmed switching times for the life of the time switch. A factory installed field replaceable lithium battery maintains accurate time keeping and calender information for a minimum of 8 years. The self contained logic board is shielded and utilizes advanced circuit board layout techniques and state of the art micro components to eliminate problems related to electrical noise interference. Transient protection for up to 6,000 volts is provided by the power board. The 1 and 2 circuit time switches are housed in a lockable steel enclosure. Both NEMA 1 and NEMA 3R enclosures are available. All standard Intermatic T100 series enclosures will accept the 1 and 2 circuit models. The 4 circuit model ET70415CR is standard in a NEMA 3R enclosure. Applications • Schools • Stores • Restaurants • Offices • Hotels • Parks • Airports • Car Lots • Apartments • Hospitals • Factories • Farms For Controlling: • Water Heaters • Process Equipment • Bells and Signals • Commercial Ovens • Lighting • Fans/Blowers/Pumps • Livestock Feeders • Heating / Ventilating Equipment • Air Conditioners • Poultry Equipment Specifications ET7232M1 Surface Mount Wired remote override for 1 & 2 circuit models ET70115C/CR and ET70215C/CR ET7232M Flushmount or Raintight Certified under Title 24, Part 6, Section 131(D) of the California Code of Regulations 120/208/240/277 V 50/60 Hz Operation or 24V 60 Hz Operation UL917 E10694 82 C22.2-177 LR3730 1 & 2 Circuit Models 4.2 lbs 1.91 kg 4 Circuit Models 6.2 lbs 2.81 kg -40°F (-40°C) to 122°F (50°C) Case (1 & 2 circuit models) – NEMA 1 – Drawn steel 7-3/4" (19.7 cm) High, 5" (12.7 cm) Wide, 3" (7.6 cm) Deep in gray finish. NEMA 3R – Drawn steel 9-3/8" (23.8 cm) high, 5-1/2" (14.0 cm) wide, 3-5/8" (9.0 cm) deep in gray finish. Both types include permanently attached side hinged door with lockable hasp. Mounting holes and/or mounting bracket included. Separate grounding terminal. Case (4 circuit model) – NEMA 3R – Heavy duty .047" 18 gauge steel in gray finish; 12-1/2" (31.7 cm) High, 8-1/4" (21.0 cm) Wide, 4" (10.2 cm) Deep. Knockouts (1 & 2 circuit models) – Combination 1/2"-3/4" nominal knockouts, one on back and each side and two on case bottom. Knockouts (4 circuit model) – Combination 1/2"-3/4" nominal knockouts, two on back one on each side and two on bottom. Also one 1" nominal knockout on bottom center. Optional Enclosures – Refer to price list (TS190) or contact factory for availability of time switch in other enclosures. Model ET70415CR available in NEMA 3R only; for flush mounting order accessory # 6ET1398GA. Special Voltages and Cycles – Line voltage models 50 or 60 Hz and field selectable for 120 (factory shipped), 208, 240, 277 Volts or low voltage models 60 Hz 24 Volts. Switch Rating, Normally Open Contacts – Each Pole; 20 amp resistive/general purpose, 12–277 Volts AC; 20 amp resistive/general purpose, 28 Volts DC; 20 amp ballast, 120–277 VAC; 1 HP, 120 VAC 60 Hz; 98 LRA; 22 FLA; 2 HP, 240 VAC 60 Hz; 80 LRA; 30 FLA; 5 amp tungsten, 120–240 VAC; 470 VA pilot duty, 12–240 VAC; TV-5, 120–240 VAC Normally Closed Contacts – 10 Amp Resistive/general purpose, 12-277 VAC; 10 Amp Resistive/general purpose, 28 Volts DC; 3 Amp ballast, 120-277 VAC; 1/4 HP, 120 VAC 60 Hz; 1/2 HP, 240 VAC 60 Hz; 30 LRA; 12 FLA; 275 VA pilot duty, 12–240 VAC Carry-over – Non volatile memory requires no backup. Time keeping and calender data maintained within 0.01% accuracy for minimum of 8 years with one factory installed, field replaceable lithium coin cell. Model # Circuits Switch Clock Supply Volts 50/60 Hz Amps (per pole) Ballast HP 120-240 ET70115C ET70115CR ET70115CR24 ET70215C ET70215CR ET70215CR24 ET70415CR ET70415CR24 1 1 1 2 2 2 4 4 SPDT SPDT SPDT SPDT SPDT SPDT SPDT SPDT 120/208/240/277 120/208/240/277 24V 60 Hz 120/208/240/277 120/208/240/277 24V 60 Hz. 120/208/240/277 24V 60 Hz 20* 20* 20* 20* 20* 20* 20* 20* 20* 20* 20* 20* 20* 20* 20* 20* 1-2 1-2 1-2 1-2 1-2 1-2 1-2 1-2 * 120/277 VAC Normally Open Contact Ratings (see specifications for complete ratings), per pole for multi-circuit models Models with CR and CR24 suffix in NEMA 3R raintight enclosure www.intermatic.com Next Generation Full Year or 7-Day 8 & 16 Circuit Electronic Time Switches These electronic time switches provide to-the-minute programming for 7-day or full year load control and reduced energy costs. A user selectable clock format for 12 hour AM/PM or 24 hour is provided for programming a minimum of 4,000 set points. Each ON and OFF switching function uses a set point. Full year control features include up to 99 different “holidays” each of which can be programmed for any duration. Any holiday or holiday duration can be left for “no load activity” or programmed for a unique load activity. Fully automatic daylight saving time adjustment, with user selectable override, and automatic leap year adjustment are also standard on the ET70000C series. Weekly programming provides single step weekday and weekend programming to simplify typical 5/2 day load control. An automatic review feature enables quick easy review of all programmed data. Flexible load control is enhanced by Astro, Pulse (from 1 to 127 seconds) and Interval options as required for outdoor lighting control, bell ringing and after hours temporary override respectively. These options can be combined, for example, to provide Astro switching with a Pulse output for outdoor lighting using a latching contactor. The Interval option provides the ability to program loads independently for override times (up to 6 days, 23 hours, 59 minutes). All models are standard in a NEMA 3R steel enclosure and include input terminals for wired remote 4 circuit override. Accessory #156ET9402A expands 8 circuit models to 8 circuits of override: accessory #156ET9403A expands 16 circuit models to 16 circuits of override. The loads can be independently overridden using a remote (up to 1,000 feet) momentary or maintained switch connected to the time switch or override accessory with bell wire. Each load in the eight and sixteen circuit models may be programmed independently, together or in groups. A non-volatile memory maintains all programmed switching times for the life of the time switch. A factory installed field replaceable lithium battery maintains accurate time keeping and calender information for a minimum of 8 years. The self contained logic board is shielded and utilizes advanced circuit board layout techniques and state of the art micro components to eliminate problems related to electrical noise interference. Transient protection for up to 6,000 volts is provided by the power board. Applications • Schools • Stores • Restaurants • Offices • Hotels • Parks • Airports • Car Lots • Apartments • Hospitals • Factories • Farms For Controlling: • Water Heaters • Process Equipment • Bells and Signals • Commercial Ovens • Lighting • Fans/Blowers/Pumps • Livestock Feeders • Heating / Ventilating Equipment • Air Conditioners • Poultry Equipment Specifications Case – 8 Circuit NEMA 3R - Heavy duty .048" steel in gray finish; 10-3/4" (27.3 cm) High, 11-1/2" (29.2 cm) Wide, 4-3/4" (12.1 cm) deep with lockable hasp. 16 Circuit NEMA 3R - Heavy duty .060" steel in gray finish; 20-5/8" (52.4 cm) High, 13-1/4" (33.7 cm) Wide, 5-1/8" (13.0 cm) Deep with lockable hasp. Knockouts – 8 Circuit - 1/2"-3/4" four on bottom, plus two 1" on bottom. 16 Circuit - 1/2"-3/4", two on each side of case, six on bottom plus one 1" on each side of case, four 1" on bottom. Optional Override for 8 and 16 Circuit Time Switches – Provides override capability for maximum available circuits; #156ET9402A for 8 circuit time switches or #156ET9403A for 16 circuit time switches. Optional Enclosures – NEMA 3R only. Switch Rating, Normally Open Contacts – 20 Amp resistive/general purpose, 12-277 VAC; 20 Amp resistive/general purpose, 28 Volts DC; 20 Amp ballast, 120-277 VAC; 1 Hp, 120 VAC 60 Hz.; 98 LRA; 22 FLA; 2 HP, 240 VAC 60 Hz; 80 LRA; 30 FLA; 5 Amp tungsten, 120-240 VAC; 470 VA pilot duty, 12-240 VAC; TV-5, 120-240 VAC Normally Closed Contacts – 10 Amp Resistive/general purpose, 12-277 VAC; 10 Amp Resistive/general purpose, 28 Volts DC; 3 Amp ballast, 120-277 VAC; 1/4 HP, 120 VAC 60 Hz; 1/2 HP, 240 VAC 60 Hz; 30 LRA; 12 FLA; 275 VA pilot duty, 12–240 VAC Carry-over – Non volatile memory requires no backup. Time keeping and calender data maintained within 0.01% accuracy for minimum of 8 years with one factory installed, field replaceable lithium coin cell. Model # Circuits Switch Clock Supply Volts 50/60 Hz Amps (per pole) Ballast HP 120-240 ET70815CR ET70815CR24 ET71615CR ET71615CR24 8 8 16 16 SPDT SPDT SPDT SPDT 120/208/240/277 24V 60 Hz 120/208/240/277 24V 60 Hz 20* 20* 20* 20* 20* 20* 20* 20* 1-2 1-2 1-2 1-2 * 120/277 VAC Normally Open Contact Ratings (see specifications for complete ratings), per pole for multi-circuit models Models with CR and CR24 suffix in NEMA 3R raintight enclosure www.intermatic.com 156ET9403A Override Accessory Certified under Title 24, Part 6, Section 131(D) of the California Code of Regulations 120/208/240/277 V 50/60 Hz Operation or 24V 60 Hz Operation UL916 E76987 C22.2-177 LR3730 8 Circuit 12.5 lbs 5.67 kg 16 Circuit 25.0 lbs 11.34 kg -40°F (-40°C) to 122°F (50°C) 83 Rated for Service Entrance, CTL Panelboard ARC Fault Current Rating 10,000 Amps The Power to Control Any Application & the Dependability of Intermatic Pre-Wired For easy installation Heavy Duty Mounting Bracket Provides secure panel mounting Deadfront Storage To store deadfront during wiring Genuine Intermatic® Time Switches Choice of models allow you to specify the exact control you need: mechanical, 24-hour or 7-day electronic or astronomic Captive Screws Convenience while panel is being serviced Lockable Enclosure Prevents unauthorized access Main Disconnect Lock Provides safety during maintenance Stainless Steel Enclosure Option Long life in the most severe environments 84 www.intermatic.com Timed Load Control Panels When Intermatic engineers set out to reinvent billboard energy control, they addressed the critical issues: application flexibility and durability. The result is the Intermatic SignMaster line, which sets a new industry standard for control and dependability. Only Intermatic SignMaster offers you: • Mechanical, Electronic or Astronomic Time Switch Options, engineered for maximum energy savings and dependability • Relay, Breaker and Multi-Circuit Options, so you get the exact electrical configuration you need for every application • Painted or Stainless Steel Enclosure Options, so you get long life in the harshest environments SM2200 Series Flexibility & Dependability Choice of time switches Heavy-Duty Mechanical The industry standard in heavy-duty switching 24 Hour & 7 Day Electronic Flexibility in schedule control, with battery backup Astronomic The ultimate in sunset-to-sunrise control, with lifetime (non-volatile) memory • Prewired for time savings and easy installation • 1 or 2 Circuit Independent Control Option provides unique scheduling for both sides of billboard • Factory Programming Option according to your needs • Lightning Arrestor Option provides panel protection for lightning prone areas • Photo Control Option low cost alternative to astronomic control • Heavy-duty 16 ga. 1008 CRS NEMA 3R Electrostatically Painted Gray Enclosure – provides durability in harsh billboard environments • NEMA 3R Stainless Enclosure Option Heavy-duty 16 ga. Type 304 stainless provides the ultimate in durability, in the most severe environments. • Mercury or “Ice Cube” Relays provides extra heavy-duty or standard duty control at a cost savings • Back Fed Breaker Disconnect or Dedicated Disconnect provides integral disconnect in the panel • Up to 8 Breaker Base provide breakers for up to (8) circuits or (36) 400-Watt metal halide fixtures SM4400 Series • 40, 80 or 120 Amp Panels handle any poster or bulletin board • Agency Listing CSA tested to US Standards • Lockable Enclosure prevents unauthorized access • Main Disconnect Lock provides maintenance safety • Captive Deadfront Screws eliminates lost hardware during installation • Deadfront Storage provides a convenient place to store deadfront during wiring SM6600 Series • Gasketless Design eliminates concerns regarding gasket deterioration -31°F (-35°C) to 122°F (50°C) www.intermatic.com All Models Available in Stainless Steel 85 Timed Load Control Panels Time Switch Options T100 Series • Heavy duty mechanism • Available in all configurations • Motor transient protected for 6,000 volts • Easy to set ET100C and ET279C Series • Seven day option • Available in all configurations • Field replaceable “AA” Alkaline battery • Dual independent circuit option (2 sides of billboard can have independent schedules) Mechanical Time Switches provide reliable long life control ET70000C Series • Eliminates the need for photo controls • Lifetime memory; no resetting ever • Auto DST, twice a year, eliminates bi-annual resetting of time switch • Available in SM4400 and SM6600 series • Dual independent circuit option (2 sides of billboard can have independent schedules) SM2200 Series Gasketless panel with two 20 Amp DPST Relays. Prewired with one 20 Amp double pole Square D homeline main breaker. 120 V output: one twin 20 Amp breaker & one single pole 20 Amp breaker (for 240 V output- quad breaker with common trip on outside and inside). Capable of controlling 40 Amps @ 120 V and 20 Amps @ 240 V or 12- 400 Watt metal halide or HID fixtures. Electronic Time Switches provide reliable to-the-minute control and 3 yr. battery backup for program and time keeping protection Electronic Astronomic Time Switches provide reliable to-the-minute control and feature lifetime memory protection and astronomic programming for “sun-tracking” SM2200 15" 9" 4.75" SM4400 Model # Time Switch/Description Photo Control Outputs SM2200-1 SM2200-2 SM2200-3 SM2200-4 SM2200-5 *** SM2200-6 *** SM2200-7 SM2200-8 SM2200S-X * SM2200LA-X ** T103M Mechanical DPST 120 V T103M Mechanical DPST 120 V EP101CM Elect. 24 Hr. SPST 120 V EP101CM Elect. 24 Hr. SPST 120 V ET279C 2 Ch. Elect. 7-Day SPST 120 V ET279C 2 Ch. Elect. 7-Day SPST 120 V EP104CM Elect. 24 Hr. DPST 240 V EP104CM Elect. 24 Hr. DPST 240 V Stainless Panel Lightning Arrestor Option - AG2401 No Yes No Yes No Yes No Yes 2 2 2 2 2 2 1 (240 V) 1 (240 V) SM4400 Series Gasketless panel with two 20 Amp DPST Relays. Prewired with one 40 Amp double pole Square D homeline main breaker. 120 V output: Six single pole 20 Amp breakers (240 V output: three double pole 20 Amp breakers). Capable of controlling 80 Amps @ 120 V and 40 Amps @ 240 V or 24- 400 Watt metal halide or HID fixtures. Model # Time Switch/Description Photo Control Outputs SM4400-1 SM4400-2 SM4400-3 SM4400-4 SM4400-5 *** SM4400-6 *** SM4400-7 SM4400-8 *** SM4400-9 *** SM4400-10 SM4400-11 SM4400-12 SM4400-13 SM4400-14 SM4400-15 *** SM4400S-X * SM4400LA-X T103M Mechanical DPST 120 V T103M Mechanical DPST 120 V EP101CM Elect. 24 Hr. SPST 120 V EP101CM Elect. 24 Hr. SPST 120 V ET279C 2 Ch. Elect. 7-Day SPST 120 V ET279C 2 Ch. Elect. 7-Day SPST 120 V ET70115C Astro SPDT 120-277 V ET70215C 2 Ch. Astro SPDT 120-277 V ET70215C 2 Ch. Astro SPDT 120-277 V T104M Mechanical DPST 208-277 V T104M Mechanical DPST 208-277 V EP104CM Elect. 24 Hr. DPST 240 V EP104CM Elect. 24 Hr. DPST 240 V ET70115C Astro SPDT 120-277 V ET70215C 2 Ch. Astro SPDT 120-277 V Stainless Panel Lightning Arrestor Option - AG2401 No Yes No Yes No Yes No No Yes No Yes No Yes No No 4 4 4 4 4 4 4 4 4 2 (240 V) 2 (240 V) 2 (240 V) 2 (240 V) 2 (240 V) 2 (240 V) SM6600 Series Gasketless panel with one 60 Amp DPST mercury relay. Split buss service- Upper buss. 120 V output: prewired with one 60 Amp double pole Square D homeline main breaker and one single pole 20 Amp breaker (240 V output: one 60 Amp double pole and one 20 Amp double pole breaker) Lower Buss - for load connections. Eight single pole 20 Amp breakers (for 240 V output - four double pole breakers). Capable of controlling 120 Amp @ 120 V and 60 Amps @ 240 V or 36- 400 Watt metal halide or HID fixtures. 17" 11" 4.75” SM6600 21" 13" 86 5" Model # Time Switch/Description Photo Control Outputs SM6600-1 SM6600-2 SM6600-3 SM6600-4 SM6600-5 SM6600-6 SM6600-7 *** SM6600-8 *** SM6600-9 SM6600-10 *** SM6600S-X * SM6600LA-X ** T103M Mechanical DPST 120 V T103M Mechanical DPST 120 V EP101CM Elect. 24 Hr. SPST 120 V EP101CM Elect. 24 Hr. SPST 120 V EP104CM Elect. 24 Hr. DPST 240 V EP104CM Elect. 24 Hr. DPST 240 V ET279C 2 Ch. Elect. 7-Day SPST 120 V ET279C 2 Ch. Elect. 7-Day SPST 120 V ET70115C Astro SPDT 120-277 V ET70215C 2 Ch. Astro SPDT 120-277 V Stainless Panel Lightning Arrestor Option - AG2401 No Yes No Yes No Yes No Yes No No 8 8 8 8 4 (240 V) 4 (240 V) 8 8 8 8 *For Stainless enclosure add “S” suffix (Example SM6600S-7) **For lightning arrestor add “LA” suffix (Example SM6600LA-7) Note: For both stainless enclosure and lightning arrestor options use “LAS” suffix (Example SM6600LAS-7) ***Both channels provide individual load control for independent control of two sides of a billboard www.intermatic.com In-Wall Timers Automatic Shut-Off Timers These energy saving timers use no electricity to operate. These timers are designed to replace any standard wall switch, single or multi-gang, and automatically limit the “ON” time of fans, lights, motors, heaters and other energy consuming loads. Time limits of 5, 15, 30 and 60 minutes and 2, 4, 6 and 12 hours are available. The “hold feature” allows the user to override the automatic shut-off function for extended use of the load as required. The decorator models are supplied with a molded (white, ivory or almond) time dial plate which is designed to fit either toggle or decorator style switch plates; single or multi-gang. No field modifications are required to fit either style switch plate. An exclusive “up front” terminal connection with teeter type terminals and an easy “press-on” knob design ensure quick and easy installation. Applications • Indoor/Outdoor Lighting • Tennis Court Lighting • Whirlpools • Self Storage Facilities • Lighting Overrides • Pumps • Porch Lights • Engine Block Heaters • Exhaust Fans • Air Conditioners • Broom Closets • Process Controls • Whole House Fans • Steam Rooms • Carriage Lights • Ventilating Fans • Bathrooms Fans • Television Sets FD Series FF Series Only 1-1/4" Deep Specifications Switch Rating – Each Pole 1 HP 125 Volt AC 50/60 Hz 2 HP 250 Volt AC 50/60 Hz 20 Amp 125 Volt AC 50/60 Hz* * Inductive 10 Amp 250 Volt AC 50/60 Hz* 10 Amp 277 Volt AC 50/60 Hz* 7 Amp 125 Volt AC Tungsten UL917 E10694 C22.2-177 LR3730 1/2 lb .23 kg 40°F (4°C) to 120°F (49°C) Caution: Do not use for sunlamps, sauna, etc.. Decorator Timers Time Cycle 5 minute 15 minute 30 minute 60 minute 2 hour 4 hour 6 hour 12 hour Commercial (FF) Series Knobs IVORY WHITE ALMOND without hold with hold SPST without hold with hold without hold only FD5M FD15MC FD30MC FD60MC FD2H FD4H FD6H FD12HC FD5MW FD15MWC FD30MWC FD60MWC FD2HW FD4HW FD6HW FD12HWC — FD15MAC FD30MAC FD60MAC — — — — — FD15MH FD30MH FD60MH — — FD6HH FD12HH — FD15MHW FD30MHW FD60MHW — — FD6HHW FD12HHW SPDT Can be used as a normally closed for “Reverse Action” applications 2 hour 4 hour 6 hour 12 hour FD32H FD34H FD36H — FD415M FD430M FD460M FD46H — To order separate components use the chart below for reference. Example shown for 15 minute timer with out hold. — — — — FD32HW FD34HW FD36HW FD312HW — — — — — — — — — — — — — — FD430MW FD460MW FD46HW — — — — — — — — — — — DPST 15 minute 30 minute 60 minute 6 hour 12 hour Color Part No. Stonedust White 146MT415A Black 146MT417A Decorator (FD) Series Knobs Color Part No. Ivory 146MT492A White 146MT494A Almond 146MT563A Mechanism only* Time dial only Ivory Decorator time dial only White Decorator time dial only Almond Decorator time dial only Suffix Example 10 P P PW PA FF15M10 FF15MP FD15MP FD15MPW FD15MPA * Mechanism only models available for “FF” Series only and are shipped with black knob. Decorator (FD) timers shipped with timer, color coordinated time dial and knob. Commercial Timers Time Cycle Without hold With hold Time Cycle SPST 5 minute 15 minute 30 minute 60 minute 2 hour 4 hour 6 hour 12 hour FF5M FF15MC FF30MC FF60MC FF2H FF4H FF6H FF12HC Without hold White With hold SPDT Can be used as a normally closed for “Reverse Action” applications FF5MH FF15MH FF30MH FF60MHC — — FF6HH FF12HHC 15 minute 30 minute 60 minute 2 hour 4 hour 6 hour 12 hour FF315M FF330M FF360M FF32H FF34H FF36H FF312H –– –– –– FF32HH FF34HH — FF312HH DPST 15 minute 30 minute 60 minute 6 hour 12 hour FF415M FF430M FF460M FF46H FF412H –– –– –– — — Commercial (FF) timers shipped with timer brushed aluminum time dial and white knob. For standard or decorator switch or combination switch/receptacle applications Ivory Wall switch plates shown not included with timer Almond See Weatherproof Covers www.intermatic.com 87 In-Wall Timers Electronic, Auto Shut-Off Timer EI40C For use with existing decorator style switch plates The EI40C effectively replaces 16 different spring-wound models, freeing up additional shelf space, providing more specification flexibility, ease of installation and absolutely silent operation. A factory supplied AAA alkaline battery provides up to three years of program protection and time keeping without AC power. A low battery indicator appears in the display when the battery requires replacement. A field selectable warning feature provides an audible and/or visual signal that the load is about to switch off. Functions to control all voltages and frequencies (within the contact ratings) with no adjustments required. Provides “true” 3-way control allowing the load interval to be started and stopped using a standard mechanical switch. Applications • Bathroom Fans • HID Lighting • Carriage Lights • Entertainment Equipment • Remote Feeding/Watering Equipment • Ceiling Fans • Fluorescent Lights • Heaters • Fountains/Pool Pumps • Refrigerated Room Lights • Whole House Fans • Incandescent PAR Lights • Recreational Vehicles • Garage/Access Doors • Library/Classroom Lights Specifications EI40AC Supplied with opaque & clear covers 50/60 Hz Operation Switch – Single switch or 3 way use (up to 200 feet) Switch Rating – Resistive (heater): 20 Amp, 120-277 VAC; Tungsten (incandescent): 15 Amp, 120 VAC; 6 Amp, 208-277 VAC; Ballast/Fluorescent: 16 Amp, 120-277 VAC; Motors: 1 H.P., 120 VAC; 2 HP, 240 VAC; 4 Amp, 12 VDC; 2 Amp, 28 VDC Size – 2-5/8" (6.67 cm) H x 1-1/4" (3.18 cm) W x 2-1/2" (6.35 cm) D; fits standard decorator or GFCI switch plate Model # Switch Volts 50/60 Hz Watts Color EI40C EI40AC Single Pole or 3-Way Single Pole or 3-Way 12-277 12-277 1800-4155* 1800-4155* White Almond * Derating for multi-gang applications not required UL917 E10694 C22.2-177 LR3730 32°F (0°C) to 104°F (40°C) 95% non-condensing humidity EI40C & EI40AC 0.5 lbs .23 kg Electronic Automatic Shut-Off Timer EI15MH This energy saving timer is designed to replace any standard wall switch, single or multi-gang, and automatically limits the “ON” time of lighting loads. This compact solid-state design with silent, state-of-the-art technology provides 2-way operation– immediate switch “OFF” or a time-delayed “OFF” after 15 minutes. To restart timer, simply switch to “OFF” for one second then move toggle switch back to TIMER position. A blocking plate, supplied with the timer, may be used to eliminate permanent “ON” mode for timed “ON” use only. Applications • Indoor/Outdoor Lighting • Halls • Bathrooms • Storerooms • Track Lighting • Closets • Pantries • Garage Lights Specifications Switch – Solid state single pole use only. For 3-way use, consult factory. Switch Rating – 40 - 500 watts incandescent or P-type ballast fluorescent, UL listed thermally protected ballast. Power Consumption – 0.6 watt in TIMER position after timed period. Size – 2-11/16" (6.83 cm) L x 1-11/16" (4.29 cm) W x 1-1/8" (2.86 cm) D. Model # Interval Volts 60 Hz Watts Color EI15MH* 15 minutes 120 40-500 Ivory toggle * With hold for continuous service or eliminate permanent “ON” by using blocking plate supplied UL917 E78300 88 C22.2-177 LR3730 32°F (0°C) to 104°F (40°C) 0.5 lbs .23 kg www.intermatic.com In-Wall Timers Electronic In-Wall Timer EI20C This easy to program timer provides up to 6 ON and 6 OFF operations which can be used for 24 hour or 7 day load control. A factory supplied AAA alkaline battery provides up to three years of program protection and time keeping without AC power. A low battery indicator appears in the display when the battery requires replacement. In addition, the display continuously shows time of day, day of the week, timer load and the load status. For use with existing decorator style switch plates The timer has an isolated single pole single throw switch which allows the timer to switch any load type, including PAR lamps and motor loads from 12 to 277 volts AC or 12 to 28 volts DC, within the specified ratings. A unique “3 wire” design allows the timer to replace, or be used in place of single switches or multiple switches for “3 way” and “4 way” applications up to 30 feet from the timer. The timer can also be used with any standard dimmer. Mounting of the timer requires a standard decorator or GFCI type switch plate and a standard junction box. Applications • Bathroom Fans • HID Lighting • Carriage Lights • Entertainment Equipment • Remote Feeding/Watering Equipment • Ceiling Fans • Fluorescent Lights • Heaters • Fountains/Pool Pumps • Whole House Fans • Incandescent PAR Lights • Recreational Vehicles • Garage/Access Doors Specifications Switch – Single switch or 3 way use (up to 30 feet). Switch Rating – Resistive (heater): 20 Amp, 120-277 VAC; Tungsten (incandescent): 15 Amp, 120 VAC; 6 Amp, 208-277 VAC; Ballast/Fluorescent: 16 Amp, 120-277 VAC; Motors: 1 HP, 120 VAC; 2 HP, 240 VAC; 4 Amp, 12 VDC; 2 Amp, 28 VDC Size – 2-5/8" (6.67 cm) H x 1-1/4" (3.18 cm) W x 2-1/2" (6.35 cm) D fits standard decorator or GFCI switch plate. Model # Switch Volts 50/60 Hz Watts Color EI20C Single Pole or 3-Way 120-277 1800-4155* White Certified under Title 24, Part 6, Section 131(D) of the California Code of Regulations 50/60 Hz Operation * Derating for multi-gang applications not required UL917 E10694 C22.2-177 LR3730 32°F (0°C) to 104°F (40°C) 95% non-condensing humidity 0.5 lbs .23 kg Heavy Duty In-Wall Timers These heavy duty timers can be used to turn on lights, fans, pumps and other heavy duty loads for energy savings, security and convenience. The timer is designed to mount to any standard junction box for replacing a wall switch. Models are available in single ON / OFF or multiple ON / OFF type. Both models have an easy to use manual override. E1020 Model E1010 equipped with a 24 hour dial divided in half-hour increments with a permanently attached “ON” and “OFF” tripper permitting single “ON / OFF” control every 24 hours. Model E1020 equipped with a multiple program dial. The dial accommodates 12 “ON” and 12 “OFF” trippers. Furnished with two “ON” and two “OFF” trippers. Both timers have three color code leads and require a hot, neutral and one side of the load. See Electronic In-Wall Timers for timers which wire “in series” with the load and require only a hot and one side of the load. Applications • Hall Lights • Paddle Fans • 1 HP Air Conditioners • Attic Fans • Ceiling Lights • Porch Lights • Coffee Makers • Industrial Fans • Whole House Fans • Outdoor Lights • Broilers • Automated Light Control E1010 Specifications Size – 4-1/4" (10.8 cm) High, 3-1/4" (9.5 cm) Wide, 1-3/8" (3.5 cm) Deep. Switch Rating – 120 VAC 60 Hz; 1440 Watts Tungsten; 12 Full load Amps.; 15 Amp max load. Timing Cycle – Minimum “ON” time 1/2 hour, maximum “ON” time 22-1/2 hours; Minimum time between any two “ON” trippers (and any two “OFF” trippers) is 2 hours. Model # Switch Volts 50/60 Hz Amps Watts Color E1010 E1020 SPST SPST 120 120 15 15 1800 1800 Stonedust white housing Stonedust white housing For additional trippers for E1020 (2 “ON” / 2 “OFF” per pack), order No. 156EB1945A UL917 C22.2-177 LR3730 www.intermatic.com E1010 1.5 lbs .7 kg E1020 1.5 lbs .7 kg 89 E1120 In-Wall Timers Compact Heavy-Duty In-Wall Timers These compact heavy-duty 24 hour timers can be used to turn on lights, fans, pumps and other heavy-duty loads for energy savings, security and convenience. Its compact, quiet, low profile design has easy to set tabs for precise 24 hour control. Models are available for single gang, 2-gang and dual timer applications. Easy set tabs provide for minimum on/off times of 20 minutes for up to 36 on/off events daily. A manual ON or OFF override provides for permanent on or off override of loads at any time. Four models are available; E1120 - a single timer model, E1220 - a single timer with a 2 gang switch plate for a toggle switch, E1221 - a single timer with a 2 gang switch plate and a decorator switch and E1222 - with dual timers. All four models include a white metal single or 2-gang switch plate as required. The toggle or decorator switch is not included with timers. Model E1221 with decorator switch plate can be wired to control a decorator style receptacle or GFCI receptacle to provide for “timed receptacle” control. The dual timer model E1222 provides control of two loads on different 24 hour schedules. Applications • Hall Lights • Porch Lights • Broilers • Ceiling Lights • Outdoor Lights • Attic Fans • Whole House Fans • Air Conditioners • Industrial Fans • Paddle Fans • Coffee Makers • Automated Light Control Specifications Size – All models 1-1/4" (3.18 cm) Deep. Model E1120 - 4-1/2" (11.43 cm) H, 2-3/4" (6.99 cm) W; Models E1220, E1221 and E1222 - 4-1/2" (11.43 cm) H, 4-9/16" (11.59 cm) W. Switch Rating – 120 Volt AC, 60 Hz, 15 Amps, 1875 Watts Resistive 1350 Watts Tungsten, 1/2 HP Motor Load, 8 Amp Inductive Manual Control – Timers can be turned on and off manually for temporary or permanent control. Color – White switch plate and trippers, black dial. E1221 E1220 UL885L E10694 C22.2-177 LR3730 E1120 1.25 lbs .6 kg E1220 1.375 lbs .62 kg Model # Plate Only Switch Volts/60 Hz Amps Watts Min. On/Off Time Max. On Time E1120 E1220 E1221 24EB5495 24EB5497 24EB5524 SPST SPST SPST 120 120 120 15 15 15 1875 1875 1875 20 mins. 20 mins. 20 mins. 23 hrs. 40 mins. 23 hrs. 40 mins. 23 hrs. 40 mins. E1221 1.375 lbs .62 kg Time Switches Cycle Percentage Timer This timer provides for repetitive cycling of loads. The timer provides six field selectable total on time durations. The cycling pattern can then be selected from as little as 3% to as great as 97% of the total cycle duration. Total cycle durations are available in 30 seconds, 1 minute, 3 minutes, 5 minutes, 10 minutes and 30 minutes. The field selectable total cycle durations and “up front” user selection of the percentage of cycle time provide the ultimate flexibility in repetitive cycling control. The percentage cycle timer can be wired in series with a manual switch or time switch for “time-of-day” cycling applications. The sealed enclosure handles dusty, ammonia rich or wash-down environments, and the heavy- duty construction withstands power surges up to 6000 volts at 3000 amps. A reliable solid state electronic design ensures long life in severe duty applications. A green/red LED provides operational feedback at all times. A manual ON or OFF override allows continuous duty or cycling shutdown as required. The single pole single throw contacts are isolated from the supply power to enable switching loads with a voltage different than the supply voltage. This single model will handle all of your short cycle timing applications. Applications • Poultry Houses • Oil Wells • Irrigation • Foggers • Fans • Animation • Nurseries • Feeders • Misters • Seasonal Lighting Specifications 50/60 Hz Operation UL917 E10694 90 1.5 lbs .68 kg C22.2-177 LR3730 Size – 5-3/4" (14.60 cm) H, 3-1/2" (8.89 cm) W, 2-13/16" (7.14 cm) D. Switch Rating – 20 Amp Resistive at 28 Volts DC; 20 Amps general purpose at 240 VAC; 1 HP at 125 VAC, 2 HP at 240 VAC; Tungsten Rating - TV-5 at 240 VAC; Pilot duty 470 VA at 240 VAC; 10 Amp ballast at 277 VAC Manual Control – Timers can be turned on and off manually for temporary or permanent control. Color – Brushed aluminum housing with black molded base. Total Cycle Duration Minimum ON/OFF Maximum ON/OFF 30 Seconds 1 Minute 3 Minutes 5 Minutes 10 Minutes 30 Minutes 1 Second 2 Seconds 6 Seconds 10 Seconds 20 Seconds 1 Minute 29 Seconds 58 Seconds 2 Minutes 54 Seconds 4 Minutes 50 Seconds 9 Minutes 40 Seconds 29 Minutes Model # Switch Timer Supply 50/60 Hz Amps Watts CT1000 SPST 120 VAC or 240 VAC (field selectable) 20 4800 www.intermatic.com Time Switch Cases A. Plastic Case A. 2T2500GA Plastic Case NEMA 3R Ends rusting problems forever. Made of heavy-duty industrial grade plastic, Intermatic’s rainproof all plastic case is perfect for applications where high humidity and/or dust can be a problem. Developed for use with pool and spa equipment, the noncorroding plastic case is useful for applications in other high moisture areas such as car washes, industrial water spray areas, etc; NEMA 3R case. A hasp with a hole for lock holds the side-hinged door closed. A bracket plus two holes below the switch on the back are for mounting. Has five combination 1/2 - 3/4" nominal knockouts, one on back and each side of case, two on bottom. Type Number Description Weight (a) 2T2500GA (a) 2T2502GA Indoor / Outdoor Plastic Case – 9-3/8" x 5-1/2" x 3-3/4" Beige Indoor / Outdoor Plastic Case – 9-3/8" x 5-1/2" x 3-3/4" 1.3 lbs 1.3 lbs B. 2T2040GA Standard Case NEMA 1 B. Standard Case Drawn steel with gray powder coat paint finish. Spring hasp (with hole for seal or lock) holds permanently attached hinged door closed. Has combination 1/2" - 3/4" nominal knockouts, one on back and on each side, and two on bottom. (Except “P” Series switches which are equipped with cord-connection and receptacle.) Convenient mounting holes. NEMA Type 1. Type Number Description Weight (a) 2T2040GA (e) 2T2292GA Standard Indoor Case – 7 3/4" x 5" x 3" Indoor Case – 12-1/2" x 8-1/4" x 3-7/8" 1.4 lbs 7.0 lbs C. 2T511GA Steel Indoor/Outdoor Case NEMA 3R UL & CSA apply to all enclosures shown. UL917 E10694 C. Indoor-Outdoor Case C22.2-177 LR3730 For protecting time switch from rain, sleet, snow and ice. Drawn steel with gray or beige powder coat paint .036" construction with side-hinged door. Hasp provided for lock. Has combination 1/2-3/4" nominal knockouts, one on back and each side of case, and two on bottom. Separate grounding terminal. Convenient mounting holes. NEMA 3R. Type Number Description Weight (a) 2T511GA (a) 2T2485GA (c) 2T2331GA (e) 2T2293GA (f) 2T1985GR Standard Indoor/Outdoor Case – 9-3/8" x 5-1/2" x 3-5/8" Beige Standard Indoor/Outdoor Case – 9-3/8" x 5-1/2" x 3-5/8" Indoor/Outdoor Case – 9-3/8" x 5-1/2" x 3-5/8" Indoor/Outdoor Case – 12-1/2" x 8-1/4" x 3-7/8" Indoor/Outdoor Case – 9-3/8" x 5-1/2" x 3-5/8" 2.5 lbs 2.5 lbs 2.5 lbs 2.5 lbs 2.5 lbs 22T713 (Brackets Only) D. T10000R 2-in-1 Raintight Case D. 2-in-1 Raintight Case and Panel For use where 2 time switches are to be mounted side by side. Heavy-duty spot-welded raintight construction with powder coat paint. Hasp (with hole for lock) holds permanently attached hinged door closed. Combination 1/2" - 3/4" nominal knockouts conveniently located (two on back, five on bottom and one on each side). Top mounting brackets plus two holes below switch level on back of case. Type Number Description Weight (b) T10000R (replaces 2T2089GA) (b) T30000R (b) T40000R 2-in-1 Indoor/Outdoor Case – 10-1/2" x 10-1/2" x 4" Indoor/Outdoor Panel – 16-3/4" x 10-1/2" x 4-1/4" Indoor/Outdoor Panel – 20-3/4" x 12-3/4" x 4-1/4" 6.5 lbs 11.0 lbs 17.0 lbs E. 2T2365GA Flushmount Case Surface Mount Bracket Din Rail Bracket E. Flushmount Case For concealing mechanism in wall and giving a finished, flushed appearance. Heavy-duty, .063" formed steel construction with hinged door. Gray finish with powder coat paint. Combination 1/2" - 3/4" nominal knockouts one each side, and two on bottom, plus one 1" knockout on top and bottom. Convenient mounting holes. With or without key lock. Cutout 9 -1/8" x 6" x 4 -1/8" deep; flange 11" x 8" Type Number Description Weight (b) 2T308A (d) 2T2365GA 6ET1398GA Standard Flushmount w/Lock Flushmount Case w/Lock Flush Cover for ET70415CR and ET70415CR24 6.5 lbs 7.0 lbs 2.5 lbs F. Din Rail Mounting Bracket Heavy gauge steel mounting bracket mounts to a standard symmetrical rail TS35 according to DIN46277 and EN50022. Ideal for panel mounting of mechanical or electronic time switch controls, along side of other DIN rail mountable electrical devices. This snap-in type bracket accepts a wide range of Intermatic time switches including most T100, T170, T180, T1900, T2000, C8800, E T100, E T170, E T700 and E T70000 time switches. Type Number Description Weight 22T535GR 22T338GR Din Rail Bracket – 6" x 5" x 2" Surface Mount Snap-in Bracket – 6" x 5" x 2" 1.0 lbs 1.0 lbs www.intermatic.com A. Available for SERIES T100, T170, T180, T1100, T1200, T1400, T1900, T2000, C8800, ET100C, ET170C, ET700C and models EH10, EH40 and ET279C. B. Available for SERIES T100, T170, T180, T1900, T2000 and C8800. NOT FOR T1400/T1800/T1900 MODELS WITH BCR SUFFIX. C. Available for SERIES T100CR, T170CR, T1400BR, T1400BCR, T1800BR and T1800BCR. D. Available for SERIES ET100C, ET170C, ET700C and models EH10, EH40, ET279C, ET7115C, ET7215C, ET70215C and ET70115C. E. Available for SERIES T7400B, T7800B, T7400BC and T7800BC. F. Available for SERIES LS7000 only. 93