Time Switches – 24 Hour Dial 24 Hr. w/Skipper, Optional Carryover

advertisement
Time Switches – 24 Hour Dial
T100 Series – Designed for industrial, commercial and residential applications. Highest HP ratings in the
industry for loads up to 40 amps, providing direct 24 hr. control of most loads. Provides 1 to 12 “ON/OFF”
operations each day with minimum ON/OFF times of 1 hour. All models equipped with one “ON” and one
“OFF” tripper.
Applications
• Indoor/Outdoor Lighting
• Hydrochlorinators
• Heating/Ventilating Systems
• Post Lanterns
• Air Conditioning
• Music and Signal Systems
• Signs
• Blowers
• Fans
• Pool Heaters
• Electric Fences
• Poultry Foggers
• Filters
• Pumps
• Conveyers
Specifications
Case – Drawn steel 7-3/4" (19.7 cm) H, 5" (12.7 cm) W, 3" (7.6 cm) D in gray finish. Spring hasp, with hole for lock,
holds permanently attached, side hinged door closed. Three mounting holes on back plus handy box mounting holes.
Knockouts – Combination 1/2"–3/4" nominal knockouts, one on back and each side of case and two on bottom.
Optional Enclosures – See Time Switch Cases page for optional enclosures.
Special Voltages and Cycles – See Time Switch Motors page for available motors.
Switch Rating – Each Pole; 40 Amp Resistive, 120-480 VAC; 40 Amp Tungsten, inductive or 1000 VA pilot duty, 120-277 VAC;
2 HP (24 FLA) 120 VAC; 5 HP (28 FLA) 240 VAC single phase; 7-1/2 HP (28 FLA) 208 VAC three phase; 10 HP (28 FLA)
240 VAC three phase.
Model #
Model #
w/See-Thru Cover
Model #
Plastic Case
Switch
Clock Motor
Volts 60 Hz
AMPS
(per pole) HP Rating
T101
T102
T103
T104
T101B*
T105
T106R†
T101PCD82
––
T103PCD82
T104PCD82
––
––
––
T101P
T102P
T103P
T104P
––
––
––
SPST
SPST
DPST
DPST
SPST
1NO / 1NC**
1NO / 1NC**
125
208-277
125
208-277
125
125
208-277
40
40
40
40
40
40
40
2
5
2
5
2
2
5
* Separate clock motor terminals for switching circuits not on line voltage
** Can be wired as SPDT
† Only available in NEMA 3R case
For additional trippers (1 ON / 1 OFF per pack), order No. 156T1978A
C22.2-177
LR3730
UL917
2.75 lbs
1.25 kg
24 Hr. w/Skipper, Optional Carryover
-40°F
(-40°C)
to
130°F
(54°C)
T170 Series – Same features as the T100 Series plus a skipper option to omit operation on selected days.
Cutout screws are inserted in the dial for days which operation is to be skipped. Provides up to 10 ON/OFF
operations each day with min. ON/OFF operations of 1 hour and max. ON time of 20 hours. Includes one
CUTOUT tripper (also serves as an “ON” tripper), one “OFF” tripper and three skipping screws.
T170CR Series – Same features as the T170 Series Skipper models plus a min. of 16 hours carryover for
maintaining preset schedules during power failures. Carryover automatically rewinds when power resumes;
only one hour of rewinding time required for every two hours of power outage. 4PST models are ideal for
3-phase load control.
Specifications
Case – T170 Series same as T100 except as noted under Optional Enclosures. T170CR only in NEMA 3R drawn steel
9-3/8" (23.8 cm) H, 5-1/2" (14.0 cm) W, 3-5/8" (9.2 cm) D in gray finish. Hasp, with hole for lock, holds permanently attached,
side-hinged door closed. Bracket plus two holes on back below switch for mounting. Separate grounding terminal.
Optional Enclosures – 4 pole and 2 NO/ 2 NC models not available in standard or plastic case; only in NEMA 3R steel case.
T170CR only available in steel NEMA 3R enclosure.
Special Voltages and Cycles – See Time Switch Motors for available motors. Contact factory for availability of time switch
with 50 cycle or other voltages.
Special Voltages and Cycles – Same as T100 Series.
Switch Rating – Same as T100 Series.
C22.2-177
LR3730
UL916
-40°F
(-40°C)
to
130°F
(54°C)
2.75 lbs
1.25 kg
Same as
T100 Series
Model #
Switch
Clock Motor Volts 60 Hz
AMPS (per pole)
HP Rating
T171
T172
T173
T174
T175
T176
T1471BR*
T1472BR*
T1475BR*
T1871BR*
T171CR
T173CR
T174CR
T1471BCR*
SPST
SPST
DPST
DPST
1NO / 1NC**
1NO / 1NC**
4PST
4PST
4PST
2NO / 2NC***
SPST
DPST
DPST
4PST
125
208-277
125
208-277
125
208-277
125
208-277
480
125
125
125
208-277
125
40
40
40
40
40
40
40
40
40
40
40
40
40
40
2
5
2
5
2
5
2
5
5
2
2
2
5
2
* Separate clock motor terminals for switching circuits not on line voltage.
** Can be wired as SPDT
For additional trippers (1 ON / 1 OFF / 1 CUTOUT per pack), order No. 156T1948A
For additional skipper screws (3 skipper screws per pack), order No. 156T3085A
74
www.intermatic.com
***Can be wired as DPDT
Time Switches
Portable
This portable cord connected time switch performs all the functions of the T100 and T170 series time switches plus
it is completely portable eliminating the need for wiring. Supplied complete with 6' grounded cord set and receptacle installed.
Applications (Indoor Only)
• Photo Copiers
• Electric Water Heaters
• Ventilating Systems
• Portable Lights
• Air Conditioning
• Motors
• Signs
• Fans
• Pumps
• Space Heaters
• Poultry Foggers
• Blowers
Specifications
Case – Drawn steel 7-3/4" (19.7 cm) High, 5" (12.7 cm) Wide, 3" (7.6 cm) Deep in gray finish. Spring hasp, with hole for lock,
holds permanently attached, side hinged door closed. Three mounting holes on back plus handy box mounting holes.
Knockouts – Not applicable; prewired cord and receptacle.
Switch Rating – 15 Amp Resistive, 15 Amp Tungsten; 345 VA pilot duty (15 FLA), 125 VAC.
Model #
Switch
Clock Motor Volts 60 Hz
Amps (per pole)
Skipper Wheel
P171-30
SPST
125
15
Yes
G
For additional trippers Model Series P170 (1 ON / 1 OFF / 1 CUTOUT per pack), order No. 156T1948A
W
120V - 15A Receptacle
C22.2-177
LR3730
UL917
3 lbs
1.36 kg
-40°F
(-40°C)
to
130°F
(54°C)
C22.2-177
LR3730
UL917
2.75 lbs
1.25 kg
-40°F
(-40°C)
to
130°F
(54°C)
24 Hour Dial w/Skipper
The T1900 Supervisor Series provides up to 96 operations (48 ON / 48 OFF) every 24 hours. This series provides
operations with minimum ON / OFF times of 15 minutes. Trippers slide in and out of dial for fast accurate setting.
The skipper models provide for operations to be omitted on selected day(s) of the week. Model with carryover
provides a minimum of 16 hours of carryover to maintain preset schedules within +/- 2% accuracy during power
failures. The carryover automatically rewinds when power resumes. Only one hour is required to rewind the
carryover for each two hours of power outage.
Applications
• Oil Well Pumps
• Filters
• Blowers
• Poultry Feeders
• Heaters
• Heaters
• Process Equipment
• Recorded Music
• Dairy Equipment
• Fans
• Silo Unloaders
• Poultry Foggers
Specifications
Case – Drawn steel 7-3/4" (19.7 cm) High, 5" (12.7 cm) Wide, 3" (7.6 cm) Deep in gray finish. Spring hasp, with hole for lock,
holds permanently attached, side hinged door closed. Three mounting holes on back plus handy box mounting holes.
Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case and two on bottom.
Optional Enclosures – See Time Switch Cases for optional enclosures.
Special Voltages and Cycles – See Time Switch Motors for available motors.
Switch Rating – 20 Amp maximum 125, 208-277 and 480 VAC; 1/2 HP , 125 VAC; 1 HP, 250 VAC
Power Input – 5 Watts maximum.
Model #
Switch
Clock Motor Volts 60 Hz
Spring Wound Carryover
Amps
Skipper Wheel
T1905*
T1906
T1975
T1976*
T1975E*
SPDT
SPDT
SPDT
SPDT
SPDT
125
208-277
125
208-277
480
No
No
No
No
No
20
20
20
20
20
No
No
Yes
Yes
Yes
For additional trippers (12 per pack), order No. 156T1950A
*Add “R” suffix for NEMA 3R steel case
Replacement Snap Switch 133T701A
www.intermatic.com
75
Time Switches
Short Range Cycle Timer
Short Range Cycle Timers provide repeat cycling for “ON” times. Ten combination “ON/OFF” trippers supplied
with each switch.
Applications
• Ventilating Fans
• Fogging Equipment
• Process Equipment
• Spraying Equipment
• Poultry Feeders
• Livestock Feeders
• Pumps
• Poultry Fans
• Bulk Milk Coolers
Specifications
Case – Same as T100 Series.
Knockouts – Same as T100 Series.
Optional Enclosures – Same as T100 Series.
Switch Rating – 20 Amp Resistive 125, 208-277 VAC; 1/2 HP, 125 VAC; 1 HP, 250 VAC
C22.2-177
LR3730
UL917
2.75 lbs
1.25 kg
-40°F
(-40°C)
to
130°F
(54°C)
Model #
Switch
Clock Motor Volts 60 Hz
Dial Cycle
Tripper Actuating Time
Amps
C8855
C8815
C8835
C8865
C8825
C8845
C8866
SPDT
SPDT
SPDT
SPDT
SPDT
SPDT
SPDT
125
125
125
125
125
125
250
5 Min.
10 Min.
30 Min.
1 Hr.
2 Hr.
4 Hr.
1 Hr.
2.5 Sec.
5 Sec.
15 Sec.
30 Sec.
60 Sec.
120 Sec.
30 Sec.
20
20
20
20
20
20
20
Note: The life of the switch contacts is affected by the size and type of the controlled load. The expected minimum life at 20 amps
(resistive) load is 100,000 cycles
Replacement Snap Switch 133T773A
For additional trippers (12 trippers per pack), order No. 156T1950A
See Solid State Cycle Percentage Timer
Sprinkler/Irrigation Timer
with 14-Day Skipper
These irrigation timers permit 1 to 60 “ON” operations every 24 hours. This series is designed for water metering
in increments of 12 minutes to 20 hours - 45 minutes for maximum conservation of precious water resources. The
14-day skipper feature permits irrigation to be omitted on selected day(s) and also provides for “every other” day
operation. The “ON/OFF/AUTOMATIC” switch allows shutdown during rainy days or extended watering during
dry periods without disturbing the automatic cycle set on dial.
Applications
• Multi-Station Hydro Indexing Valves
• Irrigation Control
• Greenhouses
• Feeders
• Lawn Sprinkling
• Drip Irrigation Systems
• Pumps
Specifications
Case – Plastic NEMA 3R case. Cases include hanging bracket plus two mounting holes on back below switch for mounting.
Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case, and two on bottom.
Switch Rating –
T8805P101C – 15 Amps, 125 VAC, 1/2 HP, SPST.
R8806P101C – 25 Amps, 208-277 VAC, 2 HP, DPST relay.
R8815P101C – 25 Amps, 120 VAC, 1-1/2 HP, DPST relay.
R8816P101C – 25 Amps, 208-277 VAC, 3 HP, DPST relay.
T8845PV – 125 VAC, SPST, output 24 Volts - 20VA
C22.2-177
LR3730
UL917
76
3.75 lbs
1.7 kg
-40°F
(-40°C)
to
130°F
(54°C)
Model #
Switch
Motor Voltage 60 Hz
Output Voltage 60 Hz
AMPS (per pole)
HP Rating
T8805P101C
R8806P101C
R8815P101C*
R8816P101C*
T8845PV**
SPST
DPST
DPST
DPST
SPST
125
208-277
120
208-277
125
––
—
—
––
24
15
25
25
25
20VA
1/2
2
1-1/2
3
––
* Includes rain sensor input terminals- rain sensor not supplied
** Includes 24 volt - 20 VA transformer
For additional trippers (12 per pack), order No. 156T1950A
www.intermatic.com
Time Switches
Timing Control Center,
7-Day Dial with Carryover
This series provides photo control initiated / time switch terminated control. These time switches provide a
different “ON/OFF” program each day of the week and a spring wound carryover. These time switches are
recommended for applications where you need to turn a load “ON” at dusk and “OFF” at a preset time. The
spring wound carryover provides a carryover of 16 hours minimum to maintain accurate load control even during
power failure. When power resumes, the carryover automatically rewinds itself. Only 1 hour is required to rewind
the carryover for each 2 hours of outage. The three models provide control of 1,2 or 3 circuits. A light level adjustment is provided on the photo control. All models have single pole double throw switches and manual circuit
by-pass switches.
Unit is designed to control the contactor control circuit only. It is not recommended for direct switching of tungsten,
mercury vapor or similar loads.
Applications
• Parking Lot Lighting
• Storefront Lighting
• Landscape Lighting
• Stairway Lighting
• Billboard Lighting
• Car Lot Lighting
• Entryway Lighting
• Security Lighting
Specifications
Case – Steel in gray finish 12-1/2" (31.7 cm) high, 8-1/4" (21.0 cm) wide, 4" (10.2 cm) deep. Indoor type with toggle action
drawbolt and locking feature. Four mounting holes on back. Separate grounding terminal.
Knockouts – Combination 1/2"-3/4" nominal knockouts, two on back one on each side and two on bottom. Also one 1" nominal on
bottom center.
Optional Enclosures – None available.
Contact Rating – 15 Amp, 1/2 HP, 125/250 VAC; 420 VA pilot duty; 150 Watts Tungsten, 125 VAC (May also be used with 24 volt
systems if wired in accordance with National Electric Code Regulations.)
Model #
Description
Clock Motor Volts 60 Hz
T51211BC
Circuit A
Circuit B
Circuit A
Circuit B
Circuit C
120
—
120
—
—
T51311BC
-
Sunset, Photo Control ON - Preset Time Switch OFF
Sunset, Photo Control ON - Sunrise, Photo Control OFF
Sunset, Photo Control ON - Preset Time Switch OFF
Sunset, Photo Control ON - Sunrise, Photo Control OFF
Preset Time Switch ON - Preset Time Switch OFF
All models have separate clock motor terminals for switching circuits not on line voltage
For additional trippers (7 ON / 7 Off per pack), order No. 156T2548A
See Next Generation Electronic Time Switches with Astro Feature
C22.2-177
LR3730
UL917
10.5 lbs
4.8 kg
-40°F
(-40°C)
to
130°F
(54°C)
C22.2-177
LR3730
UL917
2.75 lbs
1.25 kg
-40°F
(-40°C)
to
130°F
(54°C)
Compact, 7-Day
The T2000 Series provides up to 84 (42 “ON/OFF”) operations each week. Minimum “ON/OFF” times for this
series are 2 hours each providing up to 6 “ON/OFF” operations each day.
Applications
• Heating
• Lights
• Air Conditioning
• Pumps
• Ventilating
• Motors
• Defrost Control
• Fans
Specifications
Case – Drawn steel 7-3/4" (19.7 cm) high, 5" (12.7 cm) wide, 3" (7.6 cm) deep in gray finish. Spring hasp, with hole for lock,
holds permanently attached, side hinged door closed. Three mounting holes on back plus handy box mounting holes.
Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case and two on bottom.
Optional Enclosures – See Time Switch Cases for optional enclosures.
Special Voltages and Cycles – See Time Switch Motors for available motors.
Switch Rating – 20 Amp Resistive, 125 and 208-277 VAC; 1/2 HP 125 VAC; 1 HP 250 VAC
Model #
Switch
Clock Motor Volts 60 Hz
Amps
T2005
T2006
SPDT
SPDT
125
208-277
20
20
For additional trippers (12 per pack), order No. 156T1950A
Replacement Snap Switch 133T701A
www.intermatic.com
77
Time Switches
7-Day Dial With & Without Carryover
These time switches provide a different “ON/OFF” program each day of the week. They also provide for 4 pole
single throw and 4 pole (2NO/2NC) switching. This series provides true 7-day load control with minimum ON
and minimum OFF times of 3-1/2 hours. The “BC” models with carryover provide a carryover of 16 hours
minimum to maintain accurate load control even during power failure. When power resumes, the carryover
automatically rewinds itself. Only 1 hour is required to rewind the carryover for each 2 hours of outage.
Applications
• Heating
• Outdoor Lighting
• Ventilating Systems
• Air Conditioning
• Motors
• Fans
• Pumps
• Signs
• Filters
• Indoor Lighting
• Billboards
• 3 Phase Loads
Specifications
C22.2-177
LR3730
UL917
Models
without
carryover
8 lbs
3.6 kg
Models
with
carryover
9 lbs
4.1 kg
Case – Steel in gray finish 12-1/2" (31.7 cm) high, 8-1/4" (21.0 cm) wide, 4" (10.2 cm) deep. Indoor type with
toggle action drawbolt and locking feature. Four mounting holes on back. Separate grounding terminal.
Knockouts – Combination 1/2"-3/4" nominal knockouts, two on back one on each side and two on bottom.
Also one 1" nominal on bottom center.
Optional Enclosures – See Time Switch Cases for optional enclosures.
Special Voltages and Cycles – See Time Switch Motors for available motors. Contact factory for availability of
time switch with 50 cycle or other voltages.
Switch Rating – Each Pole 40 amp resistive, 120-480 VAC; 40 amp tungsten, inductive or 1000 VA pilot duty, 120-277 VAC;
2 HP (24 FLA) 120 VAC; 5 HP (28 FLA) 240 VAC single phase; 7-1/2 HP (28 FLA) 208 VAC three phase; 10 HP
(28 FLA) 240 VAC three phase.
Carryover – Minimum time - mechanical operation: 16 hours. Carryover accuracy +/-2%.
-40°F
(-40°C)
to
130°F
(54°C)
Model l#
Model with CarryOver
Switch
Clock Motor Volts 60 Hz
Amps (per pole)
T7401B
T7402B
T7801B
T7802B
T7401BC
T7402BC
T7801BC
T7802BC
4PST
4PST
2NO/2NC
2NO/2NC
125
208-277
125
208-277
40
40
40
40
* All models (B or BC suffix) have separate clock motor terminals.for switching circuits not on line voltage
For additional trippers (7 ON / 7 OFF per pack), order No. 156T2548A
Astro Dial With Skipper & Carryover
This time switch self adjusts for seasonal changes. The astronomic dial; automatically adjusts itself as the days
grow shorter or longer. A skipper provides lighting control to be omitted on selected day(s) of the week. The carryover is designed to maintain preset schedule during power outages for a minimum of 16 hours. Only 1 hour is
required to rewind the carryover for each 2 hours of outage. The 3PST switch configuration provides for control
of 3-phase lighting. Three skipper screws are furnished.
Lighting Applications
• Parking Lots
• Entryways
• Landscape Lights
• Security
• Stairways
• Storefronts
• Billboards
• Car Lots
Specifications
Case – NEMA 3R drawn steel 11-1/2" (29.2 cm) high, 8-1/4" (20.9 cm) wide, 4-1/2" (11.4 cm) deep in gray finish.
Hasp, with hole for lock, holds permanently attached, side hinged door closed. Mounting bracket plus two holes below switch
on back for mounting. Separate grounding terminal.
Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case and two on bottom.
Optional Enclosures – None.
Switch Rating – Each pole: 40 amp tungsten up to 277 VAC; 1 HP, 120 VAC; 690 VA pilot duty.
UL917
E10694
C22.2-177
LR3730
Models
V45471CR &
V45472CR
9 lbs
4.1 kg
Other
Models
5 lbs
2.3 kg
-40°F
(-40°C)
to
130°F
(54°C)
Model #
Switch
Clcock Motor Volts 60 Hz
Amps
V45471CR*
V45472CR*
V45471R
V45472R
3PST
3PST
3PST
3PST
125
208-277
125
208-277
40
40
40
40
# Indicate City and State nearest installation when ordering.
* Includes spring wound carryover
For additional skipper screws (3 skipper screws per pack), order No. 156T1957A
See Next Generation Electronic Time Switches with Astro Feature
78
www.intermatic.com
Water Heater Time Switches
The WH40 provides a convenient external override switch. Utilities in many areas of the country offer two electric
rates for residential or commercial customers. One rate has the regular daytime electrical rate, the other is “off
peak” rate. The off peak rate provides customers with “lower-priced” electricity during the nighttime and weekend
periods. These time switches allow the customer to shift electricity use into these off-peak time periods in an
attempt to save utility costs.
Applications
Water Heater Control for:
• Residential
• Commercial
• Industrial
• Institutional / Schools
• Military Facilities
Specifications
Case – Drawn steel 7-3/4" (19.7 cm) High, 5" (12.7 cm) Wide, 3" (7.6 cm) Deep in gray finish. Spring hasp, with hole for lock,
holds permanently attached, side hinged door closed. Three mounting holes on back plus handy box mounting holes.
Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case and two on bottom.
Special Voltages and Cycles – See Time Switch Motors for available motors.
Switch Rating – 40 Amp Resistive, Inductive or Tungsten 120-277 VAC; 1000 VA pilot duty 120-277 VAC; 2 HP (24 FLA) 125 VAC;
5 HP (28 FLA) 240 VAC.
Model #
Switch
Clock Supply Volts 60 Hz
Watts
External Switch
Amps/Pole
T104-20
WH40
DPST
DPST
208-240
250
10000
10000
No
Yes
40
40
The
"LITTLE
GRAY BOX"®
For additional trippers (1 ON / 1 OFF per pack), order No. 156T1978A
C22.2-177
LR3730
UL917
2.75 lbs
1.25 kg
-40°F
(-40°C)
to
130°F
(54°C)
Electronic Water Heater Timers
These time switches provide automatic control for electric water heaters. They provide to-the-minute accuracy
in programming and timekeeping. The time switches can be programmed for repeat daily scheduling, 5-day
working week scheduling, weekend scheduling or any individual day scheduling. Timers can be scheduled for
operation during the lowest time-of-day rates or to switch off the electric heater during period of utilities peak
power usage. The time switch can be set to operate for up to 6 on/off operations daily for a maximum of
42 on/off operations weekly. Both models provide a convenient external override switch and LED load indicator
for ease in scheduling hot water as required for extra hot water demands. The timers include a “AA” alkaline
battery carryover which protects both timekeeping and program information for a minimum of 3 years.
Applications
Water Heater Control for:
• Residential
• Military Facilities
• Institutional
• Schools
• Industrial
• Commercial
Specifications
With Manual External Override
and Load Indicator
Case – Drawn steel 7-3/4" (19.7 cm) H x 5" (12.7 cm) W x 3" (7.6 cm) D in gray finish. Spring hasp, with hole for lock,
holds permanently attached, side hinged door closed. Three mounting holes on back plus handy box mounting holes.
Knockouts – Combination 1/2"–3/4" nominal knockouts, one on back and each side of case and two on bottom.
Switch Rating – 30 Amp Resistive or Inductive 120-240 VAC; 1 HP, 120 VAC; 1-1/2 HP, 240 VAC;
5 Amps Tungsten, 120/240 VAC.
Model #
Switch
Clock Supply Volts 50/60 Hz
Watts
External Switch
Amps/Pole
EH10
EH40
SPST
DPST
120
240
3600
7200
Yes
Yes
30
30
www.intermatic.com
50/60 Hz Operation
UL916
E76987
C22.2-177
LR3730
2.75 lbs
1.25 kg
-4°F
(-20°C)
to
122°F
(50°C)
79
Electronic Time Switches
7-Day 1 & 2 Circuit
Electronic Time Switches
7 Day
ET170C
Series
7 Day
with momentary
output option
ET279C
(2 Circuit)
Certified under Title 24, Part 6, Section
131(D) of the California Code of
Regulations
50/60 Hz Operation
UL917
C22.2-177
LR3730
2.5 lbs
1.1 kg
-40°F
(-40°C)
to
155°F
(68°C)
These electronic time switches provide the to-the-minute programming for accurate load control and reduced
energy costs. Up to 20 set points or events (10 ON/10 OFF or any combination) can be preset to automatically
repeat on a weekly or daily basis. The program can be overridden at any time by placing the selector switch in
the Manual position. These time switches provide for true 7-day load control with up to 140 operations
(70 ON/70 OFF or any combination) each week. Model ET279C provides 20 operations or momentary contact
closures of 1 to 8 seconds (ten each or any combination) for two independent circuits.
All models come with a factory installed industrial grade standard “AA” alkaline battery to provide timekeeping
and automatic carry-over for a minimum of 3 years. The battery is easily replaced in the field without requiring
removal of the time switch mechanism or field wiring. These models can also be used for easy field replacement
of the T100 and T170 series mechanical time switches. Just snap out the old mechanism and snap in the new
using the existing wiring and case.
Specifications
Case – Drawn steel 7-3/4" (19.7 cm) High, 5" (12.7 cm) Wide, 3" (7.6 cm) Deep in gray finish. Spring hasp, with hole for lock,
holds permanently attached, side hinged door closed. Three mounting holes on back plus handy box mounting holes. EP Models
in plastic beige NEMA 3R raintight enclosure; 9-3/8" (23.8 cm) H, 5-1/2" (14.0 cm) W, 3-3/4" (9.5 cm) D.
Note: The electronic mechanism snaps into the standard Intermatic time switch case, replacing mechanical mechs, if desired.
Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case and two on bottom.
Optional Enclosures – See Time Switch Cases for optional enclosures.
Special Voltages and Cycles – ALL models 50 or 60 Hz.
Switch Rating – Except model ET100C. 30 Amp Inductive/Resistive, 24 / 120 / 240 / 277 VAC 60 Hz; 20 Amp Resistive,
28 VDC; 1 HP 120 VAC 60 Hz; 2 HP 240 VAC 60 Hz; 5 Amp Tungsten, 120 / 240 / VAC 60 Hz; 20 Amp ballast,
120-277 VAC 60 Hz. ET100C same ratings for 120 Volt loads only. Models ET105C and ET175C the normally closed contact
ratings are as follows: 10A Resistive/General purpose, 12 - 277VAC; 10A Resistive/General purpose, 28VDC; 3A Ballast,
120 - 277VAC; 1/4 HP, 120 VAC; 1/2 HP, 240 VAC; 30 LRA; 12 FLA; 275 VA pilot duty, 120 - 240 VAC
Carry-over – Field replaceable “AA” battery maintains program and accurate timekeeping for 3 years minimum.
Up front replacement does not require removal of mechanism or field wiring.
Wiring Terminals – #18 to #10 AWG wire.
Minimum ON/OFF Times – 1 minute.
Maximum ON/OFF Times – 24 Hour models 23 hours 59 minutes, 7-Day models 6 days 23 hours 59 minutes.
24 Hour
24 Hour Electronic Time Switches
These time switches provide the same dependable and uncomplicated performance as the T101 mechanical time
switch...plus to-the-minute programming for accurate load control and reduced energy costs. Up to 8 set points
or events (4 ON/4 OFF) can be preset to automatically repeat on a daily basis. The program can be overridden
at any time by placing the selector switch in the Manual position. An industrial grade “AA” Alkaline battery
provides 3 years minimum program and timing protection.
Applications
ET100C
Series
• Schools
• Car Lots
• Offices
• Restaurants
• Airports
• Parks
• Stores
• Apartments
• Commercial Ovens
• Livestock Feeders
• Lighting
• Poultry Equipment
• Air Conditioners
• Process Equipment
• Hotels
For Controlling:
• Water Heaters
• Fans/Blowers/Pumps
24 Hour
Model #
Switch
Clock Supply
Volts
Amps
50/60 Hz
(per pole)
HP
Rating
SPST
DPST
SPST
SPST
SPST
DPST
DPST
SPDT
120^
240^
120
120
120-277
120
120-277
120
***
***
**
***
***
***
***
***
24 Hour
EP100C
Series
UL917
C22.2-177
LR3730
80
-40°F
(-40°C)
to
155°F
(68°C)
EP101CP3^
EP104CP3^
ET100C
ET101C
ET102C
ET103C
ET104C
ET105C
Model #
Switch
Clock Supply
Volts
Amps
50/60 Hz
(per pole)
HP
Rating
SPST
SPST
DPST
DPST
SPDT
SPST*
120
120
120
240
120
120
***
***
***
***
***
***
7 Day
30
30
30
30
30
30
30
30
ET171C
ET171CR^^
ET173C
ET174C
ET175C
ET279C^^^
^ These models in NEMA 3R raintight plastic beige enclosure. 60 Hz only
^^ In NEMA 3R raintight steel enclosure
^^^ Includes field selectable momentary output for bell ringing and latching contractor control
* Each circuit for 2 circuits ** 1 @ 120 VAC *** 1 @ 120 VAC 2 @ 240 VAC
www.intermatic.com
30
30
30
30
30
30
7-Day Programmable
Electronic Time Switches and Lighting Control
These electronic time switches provide a keyboard entry system for true 7-day load control. All models provide
capability of programming up to 28 set points or events (14 ON/14 OFF or any other combination) which can
be set “to-the-minute” any time during the week. The program can be overridden at any time by placing the
selector switch in the MAN (Manual) position. A maximum of 196 set points can be programmed each week.
All models are equipped with factory installed industrial grade “AA” NiCad rechargeable batteries which provide
timekeeping (accurate within .01%) and maintain all programmed set points for a minimum of 24 hours. The
batteries are located on the cover of the case providing easy field replacement. The batteries recharge automatically in approximately 8 hours. Batteries have an estimated life in excess of 5 years. These time switches may be
used for controlling inductive loads by adding a surge suppressor of the proper voltage across the time switch
contacts. See specification note.
Model ET716CK is designed for 7-day control of outdoor lighting. It features a low voltage photo sensor (not a
photo control) with a light level slide adjustment, to ensure that lights are OFF during daylight hours. A built-in
delay prevents the load from switching due to sudden changes in light levels, such as those caused by headlights
or lightning.
Applications
• Schools
• Restaurants
ET700C Series
• Offices
• Parks
• Airports
• Apartments
• Stores
• Hospitals
• Hotels
• Factories
• Car Lots
• Farms
For Controlling:
• Water Heaters
• Process Equipment
• Bells and Signals
• Commercial Ovens
• Lighting
• Fans/Blowers/Pumps
• Livestock Feeders
• Heating/Ventilating Equipment
• Air Conditioners
• Poultry Equipment
Certified under Title 24, Part 6, Section
131(D) of the California Code of
Regulations
Applications (Model ET716CK)
• Outdoor Parking Lot Lighting
• Car Lot Lighting
• Billboard Lighting
• Security Lighting
UL916
E76987
• Landscape Lighting
• Area Lighting
C22.2-177
LR3730
2.7 lbs
1.2 kg
Specifications
-40°F
(-40°C)
to
150°F
(65°C)
Case – Drawn steel 7-3/4" (19.7 cm) high, 5" (12.7 cm) wide, 3" (7.6 cm) deep in gray finish. Spring hasp, with hole for lock,
holds permanently attached, side hinged door closed. Three mounting holes on back plus handy box mounting holes.
Note: The electronic mechanism snaps into the standard Intermatic time switch case, replacing mechanical mechs, if desired.
Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case and two on bottom.
Optional Enclosures – See Time Switch Cases for optional enclosures.
Switch Rating –
UL Listed Rating – 1 mA-5 amp resistive, 24/120/240 VAC 60 Hz; 75 VA pilot duty, 24 VAC, 60 Hz; 125 VA pilot duty,
120/240 VAC, 60 Hz
CSA Certified Switch Rating – 1 mA-5 amp resistive, 24/120/240 VAC 60 Hz; 75 VA pilot duty, 24 VAC, 60 Hz;
120 VA pilot duty, 120/240 VAC, 60 Hz.
Switch Rating (ET716CK) – Each Pole; 60 Hz unless noted. 1 mA- 5 amp resistive, 24 / 120 / 240 /277 VAC; 75 VA pilot duty,
24 VAC; 125 VA pilot duty, 120, 240 VAC; 480 VA pilot duty, 277 VAC; 2.16 amp inductive, 24, 120, 240,
277 VAC NO contacts; 0.85 amp inductive, 24, 120, 240, 277 VAC NC contacts
Operating Temperature Range – Battery capacity and charge acceptance will be less than nominal outside of -4°F (-20°C)
to 104° (40°C).
Note: For controlling inductive loads a surge suppressor must be installed across the time switch contacts. Failure to do so may result
in erratic timer operation. Order surge suppressors as follows; 176ET8A for 24 volt AC nominal loads, 176ET9A for 120 volt AC
nominal loads, 176ET10A for 240 volt AC nominal loads.
Model #
Switch
Clock Supply Volts 60 Hz
Amps (per pole)
ET715C
ET718C
ET799C
ET716CK
SPDT
4PDT
2PST**
DPDT
120
120
120
120/240/277 (Field Selectable)
5
5
5
5
ET700CK Series
** With momentary contacts
To order special cases see Optional Enclosures
UL916
E76987
www.intermatic.com
C22.2-177
LR3730
2.7 lbs
1.2 kg
-40°F
(-40°C)
to
150°F
(65°C)
81
Next Generation
Electronic Time Switches
These electronic time switches provide to-the-minute programming for 7-day or full year load control and reduced
energy costs. A user selectable clock format for 12 hour AM/PM or 24 hour is provided for programming a
minimum of 1,000 set points. Each ON and OFF switching function uses a set point. Full year control features
include up to 99 different “holidays” each of which can be programmed for any duration. Any holiday or holiday
duration can be left for “no load activity” or programmed for a unique load activity. Fully automatic daylight
saving time adjustment, with user selectable override, and automatic leap year adjustment are also standard on
the ET70000C series. Weekly programming provides single step weekday and weekend programming to simplify
typical 5/2 day load control. An automatic review feature enables quick easy review of all programmed data.
Flexible load control is enhanced by Astro, Pulse (from 1 to 127 seconds) and Interval options as required for
outdoor lighting control, bell ringing and after hours temporary override respectively. These options can be
combined, for example, to provide Astro switching with a Pulse output for outdoor lighting using a latching
contactor. For model ET70415CR the Interval option provides the ability to program all 4 loads independently for
override times (up to 6 days, 23 hours, 59 minutes). The loads can be independently overridden using a remote
(up to 1,000 feet) momentary or maintained switch connected to the time switch with bell wire. Each load in the
two and four circuit models may be programmed independently, together or in groups.
A non-volatile memory maintains all programmed switching times for the life of the time switch. A factory installed
field replaceable lithium battery maintains accurate time keeping and calender information for a minimum of
8 years. The self contained logic board is shielded and utilizes advanced circuit board layout techniques and state
of the art micro components to eliminate problems related to electrical noise interference. Transient protection for
up to 6,000 volts is provided by the power board.
The 1 and 2 circuit time switches are housed in a lockable steel enclosure. Both NEMA 1 and NEMA 3R
enclosures are available. All standard Intermatic T100 series enclosures will accept the 1 and 2 circuit models.
The 4 circuit model ET70415CR is standard in a NEMA 3R enclosure.
Applications
• Schools
• Stores
• Restaurants
• Offices
• Hotels
• Parks
• Airports
• Car Lots
• Apartments
• Hospitals
• Factories
• Farms
For Controlling:
• Water Heaters
• Process Equipment
• Bells and Signals
• Commercial Ovens
• Lighting
• Fans/Blowers/Pumps
• Livestock Feeders
• Heating / Ventilating Equipment
• Air Conditioners
• Poultry Equipment
Specifications
ET7232M1
Surface Mount
Wired remote override for
1 & 2 circuit models
ET70115C/CR and ET70215C/CR
ET7232M
Flushmount or Raintight
Certified under Title 24, Part 6, Section
131(D) of the California Code of
Regulations
120/208/240/277 V 50/60 Hz
Operation or 24V 60 Hz Operation
UL917
E10694
82
C22.2-177
LR3730
1 & 2 Circuit
Models
4.2 lbs
1.91 kg
4 Circuit
Models
6.2 lbs
2.81 kg
-40°F
(-40°C)
to
122°F
(50°C)
Case (1 & 2 circuit models) – NEMA 1 – Drawn steel 7-3/4" (19.7 cm) High, 5" (12.7 cm) Wide, 3" (7.6 cm) Deep in
gray finish. NEMA 3R – Drawn steel 9-3/8" (23.8 cm) high, 5-1/2" (14.0 cm) wide, 3-5/8" (9.0 cm) deep in gray finish.
Both types include permanently attached side hinged door with lockable hasp. Mounting holes and/or mounting bracket included.
Separate grounding terminal.
Case (4 circuit model) – NEMA 3R – Heavy duty .047" 18 gauge steel in gray finish; 12-1/2" (31.7 cm) High,
8-1/4" (21.0 cm) Wide, 4" (10.2 cm) Deep.
Knockouts (1 & 2 circuit models) – Combination 1/2"-3/4" nominal knockouts, one on back and each side and two on
case bottom.
Knockouts (4 circuit model) – Combination 1/2"-3/4" nominal knockouts, two on back one on each side and two on bottom.
Also one 1" nominal knockout on bottom center.
Optional Enclosures – Refer to price list (TS190) or contact factory for availability of time switch in other enclosures.
Model ET70415CR available in NEMA 3R only; for flush mounting order accessory # 6ET1398GA.
Special Voltages and Cycles – Line voltage models 50 or 60 Hz and field selectable for 120 (factory shipped), 208, 240,
277 Volts or low voltage models 60 Hz 24 Volts.
Switch Rating, Normally Open Contacts – Each Pole; 20 amp resistive/general purpose, 12–277 Volts AC; 20 amp
resistive/general purpose, 28 Volts DC; 20 amp ballast, 120–277 VAC; 1 HP, 120 VAC 60 Hz; 98 LRA; 22 FLA; 2 HP, 240 VAC 60 Hz;
80 LRA; 30 FLA; 5 amp tungsten, 120–240 VAC; 470 VA pilot duty, 12–240 VAC; TV-5, 120–240 VAC
Normally Closed Contacts – 10 Amp Resistive/general purpose, 12-277 VAC; 10 Amp Resistive/general purpose, 28 Volts DC;
3 Amp ballast, 120-277 VAC; 1/4 HP, 120 VAC 60 Hz; 1/2 HP, 240 VAC 60 Hz; 30 LRA; 12 FLA; 275 VA pilot duty, 12–240 VAC
Carry-over – Non volatile memory requires no backup. Time keeping and calender data maintained within 0.01% accuracy for
minimum of 8 years with one factory installed, field replaceable lithium coin cell.
Model #
Circuits
Switch
Clock Supply Volts 50/60 Hz
Amps (per pole)
Ballast
HP 120-240
ET70115C
ET70115CR
ET70115CR24
ET70215C
ET70215CR
ET70215CR24
ET70415CR
ET70415CR24
1
1
1
2
2
2
4
4
SPDT
SPDT
SPDT
SPDT
SPDT
SPDT
SPDT
SPDT
120/208/240/277
120/208/240/277
24V 60 Hz
120/208/240/277
120/208/240/277
24V 60 Hz.
120/208/240/277
24V 60 Hz
20*
20*
20*
20*
20*
20*
20*
20*
20*
20*
20*
20*
20*
20*
20*
20*
1-2
1-2
1-2
1-2
1-2
1-2
1-2
1-2
* 120/277 VAC Normally Open Contact Ratings (see specifications for complete ratings), per pole for multi-circuit models
Models with CR and CR24 suffix in NEMA 3R raintight enclosure
www.intermatic.com
Next Generation
Full Year or 7-Day 8 & 16 Circuit Electronic
Time Switches
These electronic time switches provide to-the-minute programming for 7-day or full year load control and reduced
energy costs. A user selectable clock format for 12 hour AM/PM or 24 hour is provided for programming a
minimum of 4,000 set points. Each ON and OFF switching function uses a set point. Full year control features
include up to 99 different “holidays” each of which can be programmed for any duration. Any holiday or holiday
duration can be left for “no load activity” or programmed for a unique load activity. Fully automatic daylight
saving time adjustment, with user selectable override, and automatic leap year adjustment are also standard on
the ET70000C series. Weekly programming provides single step weekday and weekend programming to simplify
typical 5/2 day load control. An automatic review feature enables quick easy review of all programmed data.
Flexible load control is enhanced by Astro, Pulse (from 1 to 127 seconds) and Interval options as required for
outdoor lighting control, bell ringing and after hours temporary override respectively. These options can be
combined, for example, to provide Astro switching with a Pulse output for outdoor lighting using a latching
contactor. The Interval option provides the ability to program loads independently for override times (up to 6 days,
23 hours, 59 minutes). All models are standard in a NEMA 3R steel enclosure and include input terminals for
wired remote 4 circuit override. Accessory #156ET9402A expands 8 circuit models to 8 circuits of override:
accessory #156ET9403A expands 16 circuit models to 16 circuits of override. The loads can be independently
overridden using a remote (up to 1,000 feet) momentary or maintained switch connected to the time switch or
override accessory with bell wire. Each load in the eight and sixteen circuit models may be programmed
independently, together or in groups.
A non-volatile memory maintains all programmed switching times for the life of the time switch. A factory installed
field replaceable lithium battery maintains accurate time keeping and calender information for a minimum of
8 years. The self contained logic board is shielded and utilizes advanced circuit board layout techniques and state
of the art micro components to eliminate problems related to electrical noise interference. Transient protection for
up to 6,000 volts is provided by the power board.
Applications
• Schools
• Stores
• Restaurants
• Offices
• Hotels
• Parks
• Airports
• Car Lots
• Apartments
• Hospitals
• Factories
• Farms
For Controlling:
• Water Heaters
• Process Equipment
• Bells and Signals
• Commercial Ovens
• Lighting
• Fans/Blowers/Pumps
• Livestock Feeders
• Heating / Ventilating Equipment
• Air Conditioners
• Poultry Equipment
Specifications
Case – 8 Circuit NEMA 3R - Heavy duty .048" steel in gray finish; 10-3/4" (27.3 cm) High, 11-1/2" (29.2 cm) Wide,
4-3/4" (12.1 cm) deep with lockable hasp. 16 Circuit NEMA 3R - Heavy duty .060" steel in gray finish; 20-5/8" (52.4 cm) High,
13-1/4" (33.7 cm) Wide, 5-1/8" (13.0 cm) Deep with lockable hasp.
Knockouts – 8 Circuit - 1/2"-3/4" four on bottom, plus two 1" on bottom. 16 Circuit - 1/2"-3/4", two on each side of case,
six on bottom plus one 1" on each side of case, four 1" on bottom.
Optional Override for 8 and 16 Circuit Time Switches – Provides override capability for maximum available circuits;
#156ET9402A for 8 circuit time switches or #156ET9403A for 16 circuit time switches.
Optional Enclosures – NEMA 3R only.
Switch Rating, Normally Open Contacts – 20 Amp resistive/general purpose, 12-277 VAC; 20 Amp resistive/general purpose,
28 Volts DC; 20 Amp ballast, 120-277 VAC; 1 Hp, 120 VAC 60 Hz.; 98 LRA; 22 FLA; 2 HP, 240 VAC 60 Hz;
80 LRA; 30 FLA; 5 Amp tungsten, 120-240 VAC; 470 VA pilot duty, 12-240 VAC; TV-5, 120-240 VAC
Normally Closed Contacts – 10 Amp Resistive/general purpose, 12-277 VAC; 10 Amp Resistive/general purpose,
28 Volts DC; 3 Amp ballast, 120-277 VAC; 1/4 HP, 120 VAC 60 Hz; 1/2 HP, 240 VAC 60 Hz; 30 LRA; 12 FLA;
275 VA pilot duty, 12–240 VAC
Carry-over – Non volatile memory requires no backup. Time keeping and calender data maintained within 0.01% accuracy
for minimum of 8 years with one factory installed, field replaceable lithium coin cell.
Model #
Circuits
Switch
Clock Supply Volts 50/60 Hz
Amps (per pole)
Ballast
HP 120-240
ET70815CR
ET70815CR24
ET71615CR
ET71615CR24
8
8
16
16
SPDT
SPDT
SPDT
SPDT
120/208/240/277
24V 60 Hz
120/208/240/277
24V 60 Hz
20*
20*
20*
20*
20*
20*
20*
20*
1-2
1-2
1-2
1-2
* 120/277 VAC Normally Open Contact Ratings (see specifications for complete ratings), per pole for multi-circuit models
Models with CR and CR24 suffix in NEMA 3R raintight enclosure
www.intermatic.com
156ET9403A
Override Accessory
Certified under Title 24, Part 6, Section
131(D) of the California Code of
Regulations
120/208/240/277 V 50/60 Hz
Operation or 24V 60 Hz Operation
UL916
E76987
C22.2-177
LR3730
8 Circuit
12.5 lbs
5.67 kg
16 Circuit
25.0 lbs
11.34 kg
-40°F
(-40°C)
to
122°F
(50°C)
83
Rated for Service
Entrance, CTL Panelboard
ARC Fault Current Rating
10,000 Amps
The Power to Control Any Application & the
Dependability of Intermatic
Pre-Wired
For easy installation
Heavy Duty Mounting
Bracket
Provides secure panel mounting
Deadfront Storage
To store deadfront during wiring
Genuine Intermatic®
Time Switches
Choice of models allow you to
specify the exact control you need:
mechanical, 24-hour or 7-day
electronic or astronomic
Captive Screws
Convenience while panel is being
serviced
Lockable Enclosure
Prevents unauthorized access
Main Disconnect Lock
Provides safety during maintenance
Stainless Steel
Enclosure Option
Long life in the most severe
environments
84
www.intermatic.com
Timed Load Control Panels
When Intermatic engineers set out to reinvent billboard energy control, they addressed
the critical issues: application flexibility and durability. The result is the Intermatic
SignMaster line, which sets a new industry standard for control and dependability.
Only Intermatic SignMaster offers you:
• Mechanical, Electronic or Astronomic Time Switch Options, engineered for maximum energy
savings and dependability
• Relay, Breaker and Multi-Circuit Options, so you get the exact electrical configuration you need
for every application
• Painted or Stainless Steel Enclosure Options, so you get long life in the harshest environments
SM2200 Series
Flexibility & Dependability
Choice of time switches
Heavy-Duty Mechanical
The industry standard in heavy-duty switching
24 Hour & 7 Day Electronic
Flexibility in schedule control, with battery backup
Astronomic
The ultimate in sunset-to-sunrise control, with lifetime (non-volatile) memory
• Prewired
for time savings and easy installation
• 1 or 2 Circuit Independent
Control Option
provides unique scheduling for both
sides of billboard
• Factory Programming Option
according to your needs
• Lightning Arrestor Option
provides panel protection for lightning
prone areas
• Photo Control Option
low cost alternative to astronomic
control
• Heavy-duty 16 ga. 1008 CRS
NEMA 3R Electrostatically
Painted Gray Enclosure –
provides durability in harsh billboard
environments
• NEMA 3R Stainless Enclosure
Option
Heavy-duty 16 ga. Type 304 stainless
provides the ultimate in durability, in
the most severe environments.
• Mercury or “Ice Cube” Relays
provides extra heavy-duty or standard
duty control at a cost savings
• Back Fed Breaker Disconnect
or Dedicated Disconnect
provides integral disconnect in
the panel
• Up to 8 Breaker Base
provide breakers for up to (8) circuits
or (36) 400-Watt metal halide fixtures
SM4400 Series
• 40, 80 or 120 Amp Panels
handle any poster or bulletin board
• Agency Listing
CSA tested to US Standards
• Lockable Enclosure
prevents unauthorized access
• Main Disconnect Lock
provides maintenance safety
• Captive Deadfront Screws
eliminates lost hardware during
installation
• Deadfront Storage
provides a convenient place to store
deadfront during wiring
SM6600 Series
• Gasketless Design
eliminates concerns regarding gasket
deterioration
-31°F
(-35°C)
to
122°F
(50°C)
www.intermatic.com
All Models Available in
Stainless Steel
85
Timed Load Control Panels
Time Switch Options
T100 Series
• Heavy duty mechanism
• Available in all configurations
• Motor transient protected for 6,000 volts
• Easy to set
ET100C and ET279C Series
• Seven day option
• Available in all configurations
• Field replaceable “AA” Alkaline battery
• Dual independent circuit option (2 sides of billboard can have independent schedules)
Mechanical Time
Switches provide
reliable long life
control
ET70000C Series
• Eliminates the need for photo controls
• Lifetime memory; no resetting ever
• Auto DST, twice a year, eliminates bi-annual resetting of time switch
• Available in SM4400 and SM6600 series
• Dual independent circuit option (2 sides of billboard can have independent schedules)
SM2200 Series
Gasketless panel with two 20 Amp DPST Relays. Prewired with one 20 Amp double pole Square D homeline main
breaker. 120 V output: one twin 20 Amp breaker & one single pole 20 Amp breaker (for 240 V output- quad
breaker with common trip on outside and inside). Capable of controlling 40 Amps @ 120 V and 20 Amps @ 240 V
or 12- 400 Watt metal halide or HID fixtures.
Electronic Time
Switches provide
reliable to-the-minute
control and 3 yr.
battery backup for
program and time
keeping protection
Electronic Astronomic
Time Switches provide
reliable to-the-minute
control and feature
lifetime memory
protection and astronomic programming for
“sun-tracking”
SM2200
15"
9"
4.75"
SM4400
Model #
Time Switch/Description
Photo Control
Outputs
SM2200-1
SM2200-2
SM2200-3
SM2200-4
SM2200-5 ***
SM2200-6 ***
SM2200-7
SM2200-8
SM2200S-X *
SM2200LA-X **
T103M Mechanical DPST 120 V
T103M Mechanical DPST 120 V
EP101CM Elect. 24 Hr. SPST 120 V
EP101CM Elect. 24 Hr. SPST 120 V
ET279C 2 Ch. Elect. 7-Day SPST 120 V
ET279C 2 Ch. Elect. 7-Day SPST 120 V
EP104CM Elect. 24 Hr. DPST 240 V
EP104CM Elect. 24 Hr. DPST 240 V
Stainless Panel
Lightning Arrestor Option - AG2401
No
Yes
No
Yes
No
Yes
No
Yes
2
2
2
2
2
2
1 (240 V)
1 (240 V)
SM4400 Series
Gasketless panel with two 20 Amp DPST Relays. Prewired with one 40 Amp double pole Square D homeline main
breaker. 120 V output: Six single pole 20 Amp breakers (240 V output: three double pole 20 Amp breakers). Capable
of controlling 80 Amps @ 120 V and 40 Amps @ 240 V or 24- 400 Watt metal halide or HID fixtures.
Model #
Time Switch/Description
Photo Control
Outputs
SM4400-1
SM4400-2
SM4400-3
SM4400-4
SM4400-5 ***
SM4400-6 ***
SM4400-7
SM4400-8 ***
SM4400-9 ***
SM4400-10
SM4400-11
SM4400-12
SM4400-13
SM4400-14
SM4400-15 ***
SM4400S-X *
SM4400LA-X
T103M Mechanical DPST 120 V
T103M Mechanical DPST 120 V
EP101CM Elect. 24 Hr. SPST 120 V
EP101CM Elect. 24 Hr. SPST 120 V
ET279C 2 Ch. Elect. 7-Day SPST 120 V
ET279C 2 Ch. Elect. 7-Day SPST 120 V
ET70115C Astro SPDT 120-277 V
ET70215C 2 Ch. Astro SPDT 120-277 V
ET70215C 2 Ch. Astro SPDT 120-277 V
T104M Mechanical DPST 208-277 V
T104M Mechanical DPST 208-277 V
EP104CM Elect. 24 Hr. DPST 240 V
EP104CM Elect. 24 Hr. DPST 240 V
ET70115C Astro SPDT 120-277 V
ET70215C 2 Ch. Astro SPDT 120-277 V
Stainless Panel
Lightning Arrestor Option - AG2401
No
Yes
No
Yes
No
Yes
No
No
Yes
No
Yes
No
Yes
No
No
4
4
4
4
4
4
4
4
4
2 (240 V)
2 (240 V)
2 (240 V)
2 (240 V)
2 (240 V)
2 (240 V)
SM6600 Series
Gasketless panel with one 60 Amp DPST mercury relay. Split buss service- Upper buss. 120 V output: prewired with one
60 Amp double pole Square D homeline main breaker and one single pole 20 Amp breaker (240 V output: one 60 Amp
double pole and one 20 Amp double pole breaker) Lower Buss - for load connections. Eight single pole 20 Amp breakers
(for 240 V output - four double pole breakers). Capable of controlling 120 Amp @ 120 V and 60 Amps @ 240 V or
36- 400 Watt metal halide or HID fixtures.
17"
11"
4.75”
SM6600
21"
13"
86
5"
Model #
Time Switch/Description
Photo Control
Outputs
SM6600-1
SM6600-2
SM6600-3
SM6600-4
SM6600-5
SM6600-6
SM6600-7 ***
SM6600-8 ***
SM6600-9
SM6600-10 ***
SM6600S-X *
SM6600LA-X **
T103M Mechanical DPST 120 V
T103M Mechanical DPST 120 V
EP101CM Elect. 24 Hr. SPST 120 V
EP101CM Elect. 24 Hr. SPST 120 V
EP104CM Elect. 24 Hr. DPST 240 V
EP104CM Elect. 24 Hr. DPST 240 V
ET279C 2 Ch. Elect. 7-Day SPST 120 V
ET279C 2 Ch. Elect. 7-Day SPST 120 V
ET70115C Astro SPDT 120-277 V
ET70215C 2 Ch. Astro SPDT 120-277 V
Stainless Panel
Lightning Arrestor Option - AG2401
No
Yes
No
Yes
No
Yes
No
Yes
No
No
8
8
8
8
4 (240 V)
4 (240 V)
8
8
8
8
*For Stainless enclosure add “S” suffix (Example SM6600S-7)
**For lightning arrestor add “LA” suffix (Example SM6600LA-7)
Note: For both stainless enclosure and lightning arrestor options use “LAS” suffix (Example SM6600LAS-7)
***Both channels provide individual load control for independent control of two sides of a billboard
www.intermatic.com
In-Wall Timers
Automatic Shut-Off Timers
These energy saving timers use no electricity to operate. These timers are designed to replace any standard wall
switch, single or multi-gang, and automatically limit the “ON” time of fans, lights, motors, heaters and other
energy consuming loads. Time limits of 5, 15, 30 and 60 minutes and 2, 4, 6 and 12 hours are available.
The “hold feature” allows the user to override the automatic shut-off function for extended use of the load as
required. The decorator models are supplied with a molded (white, ivory or almond) time dial plate which is
designed to fit either toggle or decorator style switch plates; single or multi-gang. No field modifications are
required to fit either style switch plate. An exclusive “up front” terminal connection with teeter type terminals and
an easy “press-on” knob design ensure quick and easy installation.
Applications
• Indoor/Outdoor Lighting
• Tennis Court Lighting
• Whirlpools
• Self Storage Facilities
• Lighting Overrides
• Pumps
• Porch Lights
• Engine Block Heaters
• Exhaust Fans
• Air Conditioners
• Broom Closets
• Process Controls
• Whole House Fans
• Steam Rooms
• Carriage Lights
• Ventilating Fans
• Bathrooms Fans
• Television Sets
FD Series
FF Series
Only 1-1/4" Deep
Specifications
Switch Rating – Each Pole
1 HP 125 Volt AC 50/60 Hz
2 HP 250 Volt AC 50/60 Hz
20 Amp 125 Volt AC 50/60 Hz*
* Inductive
10 Amp 250 Volt AC 50/60 Hz*
10 Amp 277 Volt AC 50/60 Hz*
7 Amp 125 Volt AC Tungsten
UL917
E10694
C22.2-177
LR3730
1/2 lb
.23 kg
40°F
(4°C)
to
120°F
(49°C)
Caution: Do not use for sunlamps, sauna, etc..
Decorator Timers
Time Cycle
5 minute
15 minute
30 minute
60 minute
2 hour
4 hour
6 hour
12 hour
Commercial (FF) Series Knobs
IVORY
WHITE
ALMOND
without hold with hold
SPST
without hold with hold
without hold only
FD5M
FD15MC
FD30MC
FD60MC
FD2H
FD4H
FD6H
FD12HC
FD5MW
FD15MWC
FD30MWC
FD60MWC
FD2HW
FD4HW
FD6HW
FD12HWC
—
FD15MAC
FD30MAC
FD60MAC
—
—
—
—
—
FD15MH
FD30MH
FD60MH
—
—
FD6HH
FD12HH
—
FD15MHW
FD30MHW
FD60MHW
—
—
FD6HHW
FD12HHW
SPDT Can be used as a normally closed for “Reverse Action” applications
2 hour
4 hour
6 hour
12 hour
FD32H
FD34H
FD36H
—
FD415M
FD430M
FD460M
FD46H
—
To order separate components use the
chart below for reference.
Example shown for 15 minute timer with out hold.
—
—
—
—
FD32HW
FD34HW
FD36HW
FD312HW
—
—
—
—
—
—
—
—
—
—
—
—
—
—
FD430MW
FD460MW
FD46HW
—
—
—
—
—
—
—
—
—
—
—
DPST
15 minute
30 minute
60 minute
6 hour
12 hour
Color
Part No.
Stonedust White
146MT415A
Black
146MT417A
Decorator (FD) Series Knobs
Color
Part No.
Ivory
146MT492A
White
146MT494A
Almond
146MT563A
Mechanism only*
Time dial only
Ivory Decorator time dial only
White Decorator time dial only
Almond Decorator time dial only
Suffix
Example
10
P
P
PW
PA
FF15M10
FF15MP
FD15MP
FD15MPW
FD15MPA
* Mechanism only models available for “FF” Series only and are
shipped with black knob.
Decorator (FD) timers shipped with timer, color coordinated time dial and knob.
Commercial Timers
Time Cycle
Without hold
With hold
Time Cycle
SPST
5 minute
15 minute
30 minute
60 minute
2 hour
4 hour
6 hour
12 hour
FF5M
FF15MC
FF30MC
FF60MC
FF2H
FF4H
FF6H
FF12HC
Without hold
White
With hold
SPDT Can be used as a normally closed for “Reverse Action” applications
FF5MH
FF15MH
FF30MH
FF60MHC
—
—
FF6HH
FF12HHC
15 minute
30 minute
60 minute
2 hour
4 hour
6 hour
12 hour
FF315M
FF330M
FF360M
FF32H
FF34H
FF36H
FF312H
––
––
––
FF32HH
FF34HH
—
FF312HH
DPST
15 minute
30 minute
60 minute
6 hour
12 hour
FF415M
FF430M
FF460M
FF46H
FF412H
––
––
––
—
—
Commercial (FF) timers shipped with timer brushed aluminum time dial and
white knob.
For standard or decorator
switch or combination
switch/receptacle
applications
Ivory
Wall switch plates shown
not included with timer
Almond
See Weatherproof Covers
www.intermatic.com
87
In-Wall Timers
Electronic, Auto Shut-Off Timer
EI40C
For use with existing
decorator style
switch plates
The EI40C effectively replaces 16 different spring-wound models, freeing up additional shelf space, providing
more specification flexibility, ease of installation and absolutely silent operation. A factory supplied AAA alkaline
battery provides up to three years of program protection and time keeping without AC power. A low battery
indicator appears in the display when the battery requires replacement. A field selectable warning feature
provides an audible and/or visual signal that the load is about to switch off. Functions to control all voltages and
frequencies (within the contact ratings) with no adjustments required. Provides “true” 3-way control allowing the
load interval to be started and stopped using a standard mechanical switch.
Applications
• Bathroom Fans
• HID Lighting
• Carriage Lights
• Entertainment Equipment
• Remote Feeding/Watering Equipment
• Ceiling Fans
• Fluorescent Lights
• Heaters
• Fountains/Pool Pumps
• Refrigerated Room Lights
• Whole House Fans
• Incandescent PAR Lights
• Recreational Vehicles
• Garage/Access Doors
• Library/Classroom Lights
Specifications
EI40AC
Supplied with opaque
& clear covers
50/60 Hz Operation
Switch – Single switch or 3 way use (up to 200 feet)
Switch Rating – Resistive (heater): 20 Amp, 120-277 VAC; Tungsten (incandescent): 15 Amp, 120 VAC; 6 Amp, 208-277 VAC;
Ballast/Fluorescent: 16 Amp, 120-277 VAC; Motors: 1 H.P., 120 VAC; 2 HP, 240 VAC; 4 Amp, 12 VDC; 2 Amp, 28 VDC
Size – 2-5/8" (6.67 cm) H x 1-1/4" (3.18 cm) W x 2-1/2" (6.35 cm) D; fits standard decorator or GFCI switch plate
Model #
Switch
Volts 50/60 Hz
Watts
Color
EI40C
EI40AC
Single Pole or 3-Way
Single Pole or 3-Way
12-277
12-277
1800-4155*
1800-4155*
White
Almond
* Derating for multi-gang applications not required
UL917
E10694
C22.2-177
LR3730
32°F
(0°C)
to
104°F
(40°C)
95%
non-condensing
humidity
EI40C
&
EI40AC
0.5 lbs
.23 kg
Electronic Automatic Shut-Off Timer
EI15MH
This energy saving timer is designed to replace any standard wall switch, single or multi-gang, and automatically
limits the “ON” time of lighting loads. This compact solid-state design with silent, state-of-the-art technology
provides 2-way operation– immediate switch “OFF” or a time-delayed “OFF” after 15 minutes. To restart timer,
simply switch to “OFF” for one second then move toggle switch back to TIMER position. A blocking plate, supplied
with the timer, may be used to eliminate permanent “ON” mode for timed “ON” use only.
Applications
• Indoor/Outdoor Lighting
• Halls
• Bathrooms
• Storerooms
• Track Lighting
• Closets
• Pantries
• Garage Lights
Specifications
Switch – Solid state single pole use only. For 3-way use, consult factory.
Switch Rating – 40 - 500 watts incandescent or P-type ballast fluorescent, UL listed thermally protected ballast.
Power Consumption – 0.6 watt in TIMER position after timed period.
Size – 2-11/16" (6.83 cm) L x 1-11/16" (4.29 cm) W x 1-1/8" (2.86 cm) D.
Model #
Interval
Volts 60 Hz
Watts
Color
EI15MH*
15 minutes
120
40-500
Ivory toggle
* With hold for continuous service or eliminate permanent “ON” by using blocking plate supplied
UL917
E78300
88
C22.2-177
LR3730
32°F
(0°C)
to
104°F
(40°C)
0.5 lbs
.23 kg
www.intermatic.com
In-Wall Timers
Electronic In-Wall Timer
EI20C
This easy to program timer provides up to 6 ON and 6 OFF operations which can be used for 24 hour or 7 day
load control. A factory supplied AAA alkaline battery provides up to three years of program protection and time
keeping without AC power. A low battery indicator appears in the display when the battery requires replacement.
In addition, the display continuously shows time of day, day of the week, timer load and the load status.
For use
with existing
decorator style
switch plates
The timer has an isolated single pole single throw switch which allows the timer to switch any load type, including
PAR lamps and motor loads from 12 to 277 volts AC or 12 to 28 volts DC, within the specified ratings. A unique
“3 wire” design allows the timer to replace, or be used in place of single switches or multiple switches for “3 way”
and “4 way” applications up to 30 feet from the timer. The timer can also be used with any standard dimmer.
Mounting of the timer requires a standard decorator or GFCI type switch plate and a standard junction box.
Applications
• Bathroom Fans
• HID Lighting
• Carriage Lights
• Entertainment Equipment
• Remote Feeding/Watering Equipment
• Ceiling Fans
• Fluorescent Lights
• Heaters
• Fountains/Pool Pumps
• Whole House Fans
• Incandescent PAR Lights
• Recreational Vehicles
• Garage/Access Doors
Specifications
Switch – Single switch or 3 way use (up to 30 feet).
Switch Rating – Resistive (heater): 20 Amp, 120-277 VAC; Tungsten (incandescent): 15 Amp, 120 VAC; 6 Amp, 208-277 VAC;
Ballast/Fluorescent: 16 Amp, 120-277 VAC; Motors: 1 HP, 120 VAC; 2 HP, 240 VAC; 4 Amp, 12 VDC; 2 Amp, 28 VDC
Size – 2-5/8" (6.67 cm) H x 1-1/4" (3.18 cm) W x 2-1/2" (6.35 cm) D fits standard decorator or GFCI switch plate.
Model #
Switch
Volts 50/60 Hz
Watts
Color
EI20C
Single Pole or 3-Way
120-277
1800-4155*
White
Certified under Title 24, Part 6, Section
131(D) of the California Code of
Regulations
50/60 Hz Operation
* Derating for multi-gang applications not required
UL917
E10694
C22.2-177
LR3730
32°F
(0°C)
to
104°F
(40°C)
95%
non-condensing
humidity
0.5 lbs
.23 kg
Heavy Duty In-Wall Timers
These heavy duty timers can be used to turn on lights, fans, pumps and other heavy duty loads for energy savings,
security and convenience. The timer is designed to mount to any standard junction box for replacing a wall
switch. Models are available in single ON / OFF or multiple ON / OFF type. Both models have an easy to use
manual override.
E1020
Model E1010 equipped with a 24 hour dial divided in half-hour increments with a permanently attached “ON”
and “OFF” tripper permitting single “ON / OFF” control every 24 hours. Model E1020 equipped with a multiple
program dial. The dial accommodates 12 “ON” and 12 “OFF” trippers. Furnished with two “ON” and two “OFF”
trippers. Both timers have three color code leads and require a hot, neutral and one side of the load.
See Electronic In-Wall Timers for timers which wire “in series” with the load and require only a hot and one side
of the load.
Applications
• Hall Lights
• Paddle Fans
• 1 HP Air Conditioners
• Attic Fans
• Ceiling Lights
• Porch Lights
• Coffee Makers
• Industrial Fans
• Whole House Fans
• Outdoor Lights
• Broilers
• Automated Light Control
E1010
Specifications
Size – 4-1/4" (10.8 cm) High, 3-1/4" (9.5 cm) Wide, 1-3/8" (3.5 cm) Deep.
Switch Rating – 120 VAC 60 Hz; 1440 Watts Tungsten; 12 Full load Amps.; 15 Amp max load.
Timing Cycle – Minimum “ON” time 1/2 hour, maximum “ON” time 22-1/2 hours; Minimum time between any two “ON” trippers
(and any two “OFF” trippers) is 2 hours.
Model #
Switch
Volts 50/60 Hz
Amps
Watts
Color
E1010
E1020
SPST
SPST
120
120
15
15
1800
1800
Stonedust white housing
Stonedust white housing
For additional trippers for E1020 (2 “ON” / 2 “OFF” per pack), order No. 156EB1945A
UL917
C22.2-177
LR3730
www.intermatic.com
E1010
1.5 lbs
.7 kg
E1020
1.5 lbs
.7 kg
89
E1120
In-Wall Timers
Compact Heavy-Duty In-Wall Timers
These compact heavy-duty 24 hour timers can be used to turn on lights, fans, pumps and other heavy-duty loads
for energy savings, security and convenience. Its compact, quiet, low profile design has easy to set tabs for precise
24 hour control. Models are available for single gang, 2-gang and dual timer applications. Easy set tabs provide
for minimum on/off times of 20 minutes for up to 36 on/off events daily. A manual ON or OFF override provides
for permanent on or off override of loads at any time.
Four models are available; E1120 - a single timer model, E1220 - a single timer with a 2 gang switch plate for
a toggle switch, E1221 - a single timer with a 2 gang switch plate and a decorator switch and E1222 - with dual
timers. All four models include a white metal single or 2-gang switch plate as required. The toggle or decorator
switch is not included with timers. Model E1221 with decorator switch plate can be wired to control a decorator
style receptacle or GFCI receptacle to provide for “timed receptacle” control. The dual timer model E1222
provides control of two loads on different 24 hour schedules.
Applications
• Hall Lights
• Porch Lights
• Broilers
• Ceiling Lights
• Outdoor Lights
• Attic Fans
• Whole House Fans
• Air Conditioners
• Industrial Fans
• Paddle Fans
• Coffee Makers
• Automated Light Control
Specifications
Size – All models 1-1/4" (3.18 cm) Deep. Model E1120 - 4-1/2" (11.43 cm) H, 2-3/4" (6.99 cm) W; Models E1220, E1221 and
E1222 - 4-1/2" (11.43 cm) H, 4-9/16" (11.59 cm) W.
Switch Rating – 120 Volt AC, 60 Hz, 15 Amps, 1875 Watts Resistive 1350 Watts Tungsten, 1/2 HP Motor Load, 8 Amp Inductive
Manual Control – Timers can be turned on and off manually for temporary or permanent control.
Color – White switch plate and trippers, black dial.
E1221
E1220
UL885L
E10694
C22.2-177
LR3730
E1120
1.25 lbs
.6 kg
E1220
1.375 lbs
.62 kg
Model #
Plate Only
Switch
Volts/60 Hz
Amps
Watts
Min. On/Off Time
Max. On Time
E1120
E1220
E1221
24EB5495
24EB5497
24EB5524
SPST
SPST
SPST
120
120
120
15
15
15
1875
1875
1875
20 mins.
20 mins.
20 mins.
23 hrs. 40 mins.
23 hrs. 40 mins.
23 hrs. 40 mins.
E1221
1.375 lbs
.62 kg
Time Switches
Cycle Percentage Timer
This timer provides for repetitive cycling of loads. The timer provides six field selectable total on time durations.
The cycling pattern can then be selected from as little as 3% to as great as 97% of the total cycle duration. Total
cycle durations are available in 30 seconds, 1 minute, 3 minutes, 5 minutes, 10 minutes and 30 minutes. The field
selectable total cycle durations and “up front” user selection of the percentage of cycle time provide the ultimate
flexibility in repetitive cycling control. The percentage cycle timer can be wired in series with a manual switch or
time switch for “time-of-day” cycling applications.
The sealed enclosure handles dusty, ammonia rich or wash-down environments, and the heavy- duty construction
withstands power surges up to 6000 volts at 3000 amps. A reliable solid state electronic design ensures long life
in severe duty applications. A green/red LED provides operational feedback at all times. A manual ON or OFF
override allows continuous duty or cycling shutdown as required.
The single pole single throw contacts are isolated from the supply power to enable switching loads with a voltage
different than the supply voltage. This single model will handle all of your short cycle timing applications.
Applications
• Poultry Houses
• Oil Wells
• Irrigation
• Foggers
• Fans
• Animation
• Nurseries
• Feeders
• Misters
• Seasonal Lighting
Specifications
50/60 Hz Operation
UL917
E10694
90
1.5 lbs
.68 kg
C22.2-177
LR3730
Size – 5-3/4" (14.60 cm) H, 3-1/2" (8.89 cm) W, 2-13/16" (7.14 cm) D.
Switch Rating – 20 Amp Resistive at 28 Volts DC; 20 Amps general purpose at 240 VAC; 1 HP at 125 VAC, 2 HP at 240 VAC;
Tungsten Rating - TV-5 at 240 VAC; Pilot duty 470 VA at 240 VAC; 10 Amp ballast at 277 VAC
Manual Control – Timers can be turned on and off manually for temporary or permanent control.
Color – Brushed aluminum housing with black molded base.
Total Cycle Duration
Minimum ON/OFF
Maximum ON/OFF
30 Seconds
1 Minute
3 Minutes
5 Minutes
10 Minutes
30 Minutes
1 Second
2 Seconds
6 Seconds
10 Seconds
20 Seconds
1 Minute
29 Seconds
58 Seconds
2 Minutes 54 Seconds
4 Minutes 50 Seconds
9 Minutes 40 Seconds
29 Minutes
Model #
Switch
Timer Supply 50/60 Hz
Amps
Watts
CT1000
SPST
120 VAC or 240 VAC (field selectable)
20
4800
www.intermatic.com
Time Switch Cases
A. Plastic Case
A. 2T2500GA
Plastic Case NEMA 3R
Ends rusting problems forever.
Made of heavy-duty industrial grade plastic, Intermatic’s rainproof all plastic case is perfect for applications
where high humidity and/or dust can be a problem. Developed for use with pool and spa equipment, the noncorroding plastic case is useful for applications in other high moisture areas such as car washes, industrial water
spray areas, etc; NEMA 3R case.
A hasp with a hole for lock holds the side-hinged door closed. A bracket plus two holes below the switch on the
back are for mounting. Has five combination 1/2 - 3/4" nominal knockouts, one on back and each side of case,
two on bottom.
Type Number
Description
Weight
(a) 2T2500GA
(a) 2T2502GA
Indoor / Outdoor Plastic Case – 9-3/8" x 5-1/2" x 3-3/4"
Beige Indoor / Outdoor Plastic Case – 9-3/8" x 5-1/2" x 3-3/4"
1.3 lbs
1.3 lbs
B. 2T2040GA
Standard Case
NEMA 1
B. Standard Case
Drawn steel with gray powder coat paint finish. Spring hasp (with hole for seal or lock) holds permanently
attached hinged door closed. Has combination 1/2" - 3/4" nominal knockouts, one on back and on each side,
and two on bottom. (Except “P” Series switches which are equipped with cord-connection and receptacle.)
Convenient mounting holes. NEMA Type 1.
Type Number
Description
Weight
(a) 2T2040GA
(e) 2T2292GA
Standard Indoor Case – 7 3/4" x 5" x 3"
Indoor Case – 12-1/2" x 8-1/4" x 3-7/8"
1.4 lbs
7.0 lbs
C. 2T511GA
Steel Indoor/Outdoor
Case NEMA 3R
UL & CSA apply to all
enclosures shown.
UL917
E10694
C. Indoor-Outdoor Case
C22.2-177
LR3730
For protecting time switch from rain, sleet, snow and ice. Drawn steel with gray or beige powder coat paint .036"
construction with side-hinged door. Hasp provided for lock. Has combination 1/2-3/4" nominal knockouts, one
on back and each side of case, and two on bottom. Separate grounding terminal. Convenient mounting holes.
NEMA 3R.
Type Number
Description
Weight
(a) 2T511GA
(a) 2T2485GA
(c) 2T2331GA
(e) 2T2293GA
(f) 2T1985GR
Standard Indoor/Outdoor Case – 9-3/8" x 5-1/2" x 3-5/8"
Beige Standard Indoor/Outdoor Case – 9-3/8" x 5-1/2" x 3-5/8"
Indoor/Outdoor Case – 9-3/8" x 5-1/2" x 3-5/8"
Indoor/Outdoor Case – 12-1/2" x 8-1/4" x 3-7/8"
Indoor/Outdoor Case – 9-3/8" x 5-1/2" x 3-5/8"
2.5 lbs
2.5 lbs
2.5 lbs
2.5 lbs
2.5 lbs
22T713
(Brackets Only)
D. T10000R
2-in-1 Raintight Case
D. 2-in-1 Raintight Case and Panel
For use where 2 time switches are to be mounted side by side. Heavy-duty spot-welded raintight construction
with powder coat paint. Hasp (with hole for lock) holds permanently attached hinged door closed. Combination
1/2" - 3/4" nominal knockouts conveniently located (two on back, five on bottom and one on each side).
Top mounting brackets plus two holes below switch level on back of case.
Type Number
Description
Weight
(b) T10000R (replaces 2T2089GA)
(b) T30000R
(b) T40000R
2-in-1 Indoor/Outdoor Case – 10-1/2" x 10-1/2" x 4"
Indoor/Outdoor Panel – 16-3/4" x 10-1/2" x 4-1/4"
Indoor/Outdoor Panel – 20-3/4" x 12-3/4" x 4-1/4"
6.5 lbs
11.0 lbs
17.0 lbs
E. 2T2365GA
Flushmount Case
Surface Mount Bracket
Din Rail Bracket
E. Flushmount Case
For concealing mechanism in wall and giving a finished, flushed appearance. Heavy-duty, .063" formed steel
construction with hinged door. Gray finish with powder coat paint. Combination 1/2" - 3/4" nominal knockouts
one each side, and two on bottom, plus one 1" knockout on top and bottom. Convenient mounting holes.
With or without key lock. Cutout 9 -1/8" x 6" x 4 -1/8" deep; flange 11" x 8"
Type Number
Description
Weight
(b) 2T308A
(d) 2T2365GA
6ET1398GA
Standard Flushmount w/Lock
Flushmount Case w/Lock
Flush Cover for ET70415CR and ET70415CR24
6.5 lbs
7.0 lbs
2.5 lbs
F. Din Rail Mounting Bracket
Heavy gauge steel mounting bracket mounts to a standard symmetrical rail TS35 according to DIN46277 and
EN50022. Ideal for panel mounting of mechanical or electronic time switch controls, along side of other DIN rail
mountable electrical devices. This snap-in type bracket accepts a wide range of Intermatic time switches including
most T100, T170, T180, T1900, T2000, C8800, E T100, E T170, E T700 and E T70000 time switches.
Type Number
Description
Weight
22T535GR
22T338GR
Din Rail Bracket – 6" x 5" x 2"
Surface Mount Snap-in Bracket – 6" x 5" x 2"
1.0 lbs
1.0 lbs
www.intermatic.com
A. Available for SERIES T100, T170, T180, T1100, T1200,
T1400, T1900, T2000, C8800, ET100C, ET170C,
ET700C and models EH10, EH40 and ET279C.
B. Available for SERIES T100, T170, T180, T1900, T2000
and C8800. NOT FOR T1400/T1800/T1900 MODELS
WITH BCR SUFFIX.
C. Available for SERIES T100CR, T170CR, T1400BR,
T1400BCR, T1800BR and T1800BCR.
D. Available for SERIES ET100C, ET170C, ET700C and
models EH10, EH40, ET279C, ET7115C, ET7215C,
ET70215C and ET70115C.
E. Available for SERIES T7400B, T7800B, T7400BC and
T7800BC.
F. Available for SERIES LS7000 only.
93
Download