For ConTech Lighting Standard, High, and Super High Output Tapelight Series; White, RGB and Single Color
• Please read all instructions prior to installation.
• Product should be installed by a qualified electrician.
• Prior to installation, pleast test all tapelight components to ensure no damage has occurred during shipment and layout materials to check bill of material.
• In hardwire applications, ensure power is off at fuse box to prevent electrical shock.
ConTech POWER SUPPLY STANDARD OUTPUT HIGH OUTPUT
INPUT VOLTAGE: 12V DC 0.7W/FT 1.45W/FT
MODEL NO. WATTAGE
RUN
SUPER HIGH
OUTPUT
3.24W/F
RGB*
3.9W/FT
SIDE EMITTING SIDE EMITTING
STANDARD OUTPUT HIGH OUTPUT
0.65W/FT 1.4W/FT
TLP12VP60 60W
TLP12VHW60 60W
TLP12VHW60 277 60W
22FT 36FT 17FT 28FT 12FT 16FT 7FT 10FT 32FT 78FT** 22FT 40FT
22FT 36FT 17FT 28FT 12FT 16FT 7FT 10FT 32FT 78FT** 22FT 40FT
22FT 36FT 17FT 28FT 12FT 16FT 7FT 10FT 32FT 78FT** 22FT 40FT
*RGB Is at full power (all three LEDs are illuminated). Power consumption may vary based on color changing program.
**Max split can be split more than once, without exceeding the max single run in each leg.
• Max Run refers to the total single run of tapelight that can go on a power supply. Max Split refers to the total amount of tapelight that can go on a driver if it were separated into two runs.
• Max Run lengths are calculated with 12V DC at the start of the tape run. Voltage drop may occur if not using proper wire gauge. Please refer to the Power Supply Wiring Chart on page one of these instructions.
• Max Run lengths above are calculated with no more than 30% light loss from the start of the tape run to the end of the tape run for optimal light consistency. If run lengths are extended beyond the recommended lengths noted above, there will be inconsistent light output and voltage drop.
1
When cutting tapelight, cut only on the cut lines provided.
Cut Lines
2
Remove adhesive backing, then gently press down the tape onto the surface. Avoid contact with LEDs.
NOTE: DO NOT bend or pinch tape on a hard angle.
LED Tape
3M Backing
3
Add input connector by plugging the input connector into the beginning of the tape. For hardwire applications, an electrician can add any additional wire needed to run back to the power supply.
Hardwire connector can be field cut
Positive to Positive
4
For plug-and-play applications, simply plug power supply into a wall outlet.
Plug-and-Play
Power Supply
Input Connector
TLCIP12
1-847-559-5500
Connector
Negative to Negative www.contechlighting.com
All specifications subject to change without notice.
This document can be recycled.
TLT INST
For ConTech Lighting Standard, High, and Super High Output Tapelight Series; White, RGB and Single Color
• Always wear safety glasses when cutting aluminum channels 2
Remove the adhesive backing from the tapelight and place into mounting channel. Gently press tapelight down into the channel. Avoid pressure on the LEDs
3
Snap the clear or frosted lens into place. Add end caps to finish off the fixture.
Endcaps
Add to connector
4
Mark mounting clip locations. Use screws provided for installation. Recommended max distance between clips is 24".
Lens
1-7/8"
3/8"
1/4"
3/8"
5/8"
3/4"
1"
1/4"
35°
1/4"
3/8"
Standard:
TLACS6
Angled:
TLACA6
3/8"
5/8"
Recessed:
TLACR6
3/8"
1-1/8"
3/8"
Double Wide:
TLACD6
1"
Round:
TLACO6
IMPORTANT SAFETY INSTRUCTIONS:
• Read all the instructions before installation. Save instructions for later use.
• Turn off power at fuse or circuit breaker box before installation or before doing any maintenance work.
• Product must be grounded to avoid potential electric shock and any other potential hazards.
• Product must be mounted in locations and at heights and in a manner consistent with its intended use, and in compliance with National Electrical Code and local codes. Use of accessory equipment is not recommended.
• Installing contrary to instructions may cause unsafe conditions.
• Do not block light from the trim aperture, in whole or in part, as this may cause unsafe conditions.
• Warning: Risk of fire. Most dwellings built before 1985 have supply wire rated at 60°C. Consult a qualified electrician before installation.
• To avoid hazards to children, account for all parts and properly dispose of all packing materials.
• Call the Technical Support department at ConTech Lighting with any installation questions: 847.559.5500.
1-847-559-5500 www.contechlighting.com
All specifications subject to change without notice.
This document can be recycled.
TLT INST
For ConTech Lighting Standard, High, and Super High Output Tapelight Series; White, RGB and Single Color
To optimize performance, it is recommended to locate the power supply in the middle of your tapelight design.
High Output: Two (2) 30' runs with two (2) 60W power supplies, non-dimming
60W
Power Supply
Input Connector
60W
Power Supply
Input Connector
15' 15'
High Output: Two (2) 30' runs with two (2) 60W power supplies, dimming
60W
Power Supply
Dimming Module
Input Connector
15'
60W
Power Supply
Output Connector
Repeater
Input Connector
15'
15' 15' 15'
Super High Output: Four (4) 12' runs with four (4) 60W power supplies, dimming
60W
Power Supply
60W
Power Supply
Dimming Module
Output Connector
Input Connector
60W
Power Supply
Repeater
Output Connector
Input Connector
60W
Power Supply
Repeater
Output Connector
Input Connector
12' 12' 12'
15'
Repeater
Input Connector
12'
Power Supply Wiring Chart (Copper Wire)
Wire Gauge 20 18 16 14 12
Distance* 6 ft. 10 ft. 15 ft. 23 ft. 40 ft.
*From driver output to the input connector of the tapelight. 12 Gauge wire recommended.
1-847-559-5500 www.contechlighting.com
All specifications subject to change without notice.
This document can be recycled.
TLT INST
For ConTech Lighting Standard, High, and Super High Output Tapelight Series; White, RGB and Single Color
0-10V Dimming, WHITE LIGHT ONLY
LED Dimming Module
120VAC
Cord & Plug or Hard Wire
Power
Supply
Black
Red
Purple
Grey
Input Output
Black
Red
Black
Red
0-10V Dimmer
(Supplied by Others)
For Continuous Dimming, WHITE LIGHT ONLY
Signal Input Options:
1. Output connector from previous run of tapelight
2. Secondary dimming signal from output of dimming module
Black
Red
G
R
V
B
LED Power Repeater (TLPRPT)
Signal
Input
Output
V
B
G
R
Power Input
Black
Red
Red
Black
Power
Supply
RGB ONLY
120VAC
Cord & Plug or Hard Wire
Power
Supply
Black
Red
Input
RGB Controller
Output
O
O
O
Red
Green
Blue
120VAC
Cord & Plug or Hard Wire
RGB Tapelight
Using a DMX512 Signal.
DMX Converter
Provided by Others
DMX
DMX
IN
DMX
OUT
To Next DMX Decoder
For Daisy Chaining Multiple
DMX Decoders
120VAC
Cord & Plug or Hard Wire
1-847-559-5500
Power
Supply
Red
Black www.contechlighting.com
Power Channel V+
1 2 3 4 +
Blue
Green
Red
All specifications subject to change without notice.
RGB Tapelight
This document can be recycled.
TLT INST