iDrive AC variable speed R 2 TE YEA 1Ø, 110V / 50~60Hz, 0.2~0.75kW (¼~1HP)* 1Ø, 230V / 50~60Hz, 0.2~2.2kW (¼~3HP) 3Ø, 230V / 50~60Hz, 0.2~2.2kW (¼~3HP)* 3Ø, 400V / 50~60Hz, 0.75~2.2kW (1~3HP) E General Purpose AC Variable Speed Drives GUARAN CE, UL and cUL approvals Integrated EMC filter Basic & Advanced set-up parameters DIN rail mounting (IP20 models only) V/F and sensorless vector operating modes 8 preset frequencies PID control, with ‘sleep’ operation DC braking Thermostatic cooling fan PNP or NPN operation Remote keypad option PC and PDA set-up / test software Multi-function & RS232 and 485 option cards Options and ordering codes EDX - 020 - 11 - E iDrive Power (kW) 0.2 020 0.4 0.75 040 075 1.5 2.2 150 220 100v, 1-Phase 200v, 1-Phase 200v, 3-Phase 400v, 3-Phase iDrive/04/10 actual size 11 21 23 43 E No Filter EMC Filter built in www.imopc.com iDrive AC variable speed General Purpose AC Variable Speed Drives Power & Control Connections Optional braking resistor(s) Optional braking unit for fast stopping high-inertia loads. Braking Unit Requires suitable resistor. Power input terminals • 1-phase 100~120V • 1/3 phase 200~240V • 3-phase 380~480V PNP common terminal L1(L) T1 L2 T2 L3(N) PE T3 PE RA (1) (3) 24V (5) S2 ‘x’ digital input SW1: Digital signal selector NPN/PNP (UP = NPN / DOWN = PNP) SW2 (6) S3 (7) S4 SW2: Speed reference selector switch NPN common • Optional interface • Multi-function input output S5 (8) COM Multi-function analogue input terminal (V/mA) Multi-function output relay 250VAC, 10A resistive RB (2) (4) S1 Multi-function AC Motor S6 T+ card (2 IN/ 1 OUT) • Remote keypad port (9) +10V • Set speed (10) AIN Multi-function analogue output terminal 0~10VDC T24V/0.6A (11) COM FM Note: connect point ‘x’ to Terminal (3) for PNP operation Terminal (8) for NPN operation Specification & Dimensions All Models: Overload (A) = 150% for 60s Maximum operating temperature IP20 = 50ºc Maximum output frequency = 200Hz Carrier frequency = 4~16kHz (Derating applies above 10kHz) Safety Class = UL508C 1-ph input 200-240V 50/60Hz iDrive/04/10 3-ph input 380~480V 50/60Hz Part Number EDX… 020-21 040-21 075-21 150-21 220-21 075-43 150-43 220-43 Motor rating (kW) 0.18/0.25 0.37/0.55 0.75/1.1 1.5 2.2 0.75/1.1 1.5 2.2 Motor rating (H.P) 0.25 0.5 1 2 3 1 2 3 Rated output current (A) 1.7 3.1 4.2 7.5 10.5 2.3 3.8 5.2 Frame size 1 1 1 2 2 2 2 2 D(inches) Frame size IP20 H(mm) H(inches) W(mm) W(inches) D(mm) 1 132 5.2 77 3.03 130.5 5.13 2 132 5.2 118 4.65 148 5.83 www.imopc.com Jaguar CUB Series E TE YEA R GUARAN R TE YEA 1Ø, 230V / 50~60Hz, 0.4~2.2kW (½~3HP) 3Ø, 400V / 50~60Hz, 0.4~4.0kW (½~5HP) E General Purpose AC Variable Speed Drives GUARAN z IP20 side-by-side mounting z Optional integrated EMI filtered models z CE marked, UL / cUL approved z Revolutionary diagnostics z DC injection braking for fast stopping z Input and output phase-loss protection z High performance STV control z PID control mode as standard z Impact load stall prevention z 7 user-configurable preset speeds z 3 user-defined skip frequencies z Sink / source logic z Optional Copy unit / remote operator z Timer / one-shot operating mode z Loss-of-load output signal z Inputs configurable for ON/NOT-ON operation z Life time / service due alarm output z Internal brake chopper z RS485/Modbus RTU communication options z Jaguar Loader diagnostic software actualsize Options and ordering codes CUB Maximum continuous output current (A) 3A7 - 1A5 2A5 3A 3A7 5A 5A5 8A 9A 11A 17A JagCUB/01/09 4 E E 1 4 2 No filter Integrated EMC filter Input voltage 230v/1ph Input voltage 400v/3ph Input voltage 200v/3ph Jaguar CUB Series continued Power&Controlconnections Note: - Main Earth/Ground terminals ‘G’ shown not connected To earth for clarity. Warning: - Inverter must be earthed/grounded MC MCCB AC Power Supply 3-phase 380 to 480V 50/60Hz or 1-phase 200 to 240V 50/60Hz or RCD (if reqd) DBR (if required) Factory fitted link (if reqd) Motor L1/R (L) L2/S (N) L3/T U V W G G Potentiometer 0-10VDC (13) (12) (11) (+) (- ) (C1) (11) Current input 4-20mA DC 0-10V DC Analog output Main power circuit P1 P(+) DB N(-) EMI Filter M Ground terminals Control circuit (30C) (30B) (30A) Alarm output (For any fault) volt-free contacts (FMA) (FWD) (REV) (PLC) (X1) (X2) (X3) (CM) Digital inputs SINK SOURCE Digital output (Y1) (Y1E) (PLC) Input from (PLC) Load (max. 50mA) Specifications&Dimensions AllModels: z Overload (A) = 150% for 60s, 200% for 0.5s z Maximum operating temperature = 50ºC z Maximum output frequency = 400Hz z Carrier frequency = 0.75~15kHz Framesize 1 2 3 H(mm) 120 130 180 H(inches) 4.72 5.12 7.09 Part Number CUB… Motor rating (kW) Motor rating (H.P) Rated output current (A) Frame size Depth (mm) Depth (inches) 3A-1 0.37/0.55 0.5 3.0 1 97 3.82 3A-1E 0.37/0.55 0.5 3.0 1 117 4.60 1-phaseinput200-240V±10%50/60Hz±5% 5A-1 5A-1E 8A-1 8A-1E 0.75/1.1 0.75/1.1 1.5 1.5 1 1 2 2 5.0 5.0 8.0 8.0 1 2 2 3 142 141 151 184 5.50 5.55 5.94 7.24 Part Number CUB… Motor rating (kW) Motor rating (H.P) Rated output current (A) Frame size Depth (mm) Depth (inches) 1A5-4 0.37/0.55 0.5 1.5 2 117 4.6 1A5-4E 0.37/0.55 0.5 1.5 2 160 6.3 2A5-4 0.75/1.1 1 2.5 2 141 5.55 JagCUB/01/09 W(mm) 80 110 140 W(inches) 3.15 4.33 5.51 11A-1 2.2 3 11.0 3 141 5.55 11A-1E 2.2 3 11.0 3 184 7.28 3-phaseinput380-480V+10%-15%50/60Hz±5% 2A5-4E 3A7-4 3A7-4E 5A5-4 5A5-4E 0.75/1.1 1.5 1.5 2.2 2.2 1 2 2 3 3 2.5 3.7 3.7 5.5 5.5 2 2 3 2 3 184 141 184 141 184 7.24 5.55 7.24 5.55 7.28 9A-4 3.7/4.0 5 9.0 3 141 5.55 9A-4E 3.7/4.0 5 9.0 3 184 7.28 www.imopc.com High Performance AC Drives 0.4-400kW VXM YEA Dual rated from 5.5kW R High performance open and closed loop operation EE 5 year warranty G UA RA NT Speed or torque control 15 preset speeds FieldBus options – Profibus, DeviceNet etc RS485 port IMO loader PC software Display remote mounting Maintenance information/alarm Standard specification VXM*** Type Applied Output ratings 30kw VXM*** (K) VXMKP *1) Nominal HD (heavy duty) kW Maximum LD (light duty) kW Rated capacity *2) kVA Rated voltage *3) – – – – – – – – 3 phase 1.5 2.5 3.7 5.5 9.0 Cont. (VT use) LD A HD LD *1) Hz *10) Voltage/Frequency variations Momentary voltage dip capability *7) A (without DCR) Standard Starting torque kVA *1) Braking torque Time s – – 7.5 11 – – Duty cycle % 45 55 75 – – – – – – 15 18.5 22 – 30 37 45 55 75 90 110 132 160 200 220 280 315 400 – – – – – – 30 37 45 55 75 90 32 32 43 53 65 80 107 126 150 181 218 270 298 373 21 28 380, 400, 440, 460V/60Hz – OM: 440V/50Hz 24 30 39 45 – 60 75 16.5 23 30 37 44 – 60 75 91 112 150 176 210 253 304 377 415 520 91 112 150 176 210 253 304 377 415 520 150% of rated current for 1 min. 180% of rated current for 0.5s 110% 1 min LD 0.1 – 400 3 phase 380 to 480V 50/60Hz 3 phase 380 to 440V/50Hz 380 to 480V/60Hz *5) Frequency: +5 to -5% When the input voltage is 310V or more, the inverter can be operated continuously. When the input voltage drops below 310V from rated voltage, the inverter can be operated for 15ms. The smooth recovery method is selectable. 0.82 1.5 2.9 4.2 7.1 10.0 13.5 19.8 26.8 33.2 39.3 54 54 1.8 3.5 6.2 9.2 14.9 21.5 27.9 39.1 50.3 59.9 69.3 86 86 104 124 150 – – 0.6 1.1 2.1 3.0 5.0 7.0 9.4 14 38 93 111 136 161 196 244 267 341 19 24 >200% (with Dynamic torque-vector control selected) 150% 100% 5 5 5 3 Enclosure (IEC 60529) 5 3 2 28 38 67 47 81 100 134 160 196 232 282 352 385 491 57 70 – – – – – >180% (with Dynamic torque-vector control selected) 20% *9) 15 to 10% *9) No limit 3 2 No limit 100% Braking time: 0.0 to 30.0s Braking level: 0 to 100% of rated current IP 40 IP 00(IP20: Option) Natural cooling Standards – 110 132 160 200 220 280 315 13 18 Starting frequency: 0.1 to 60.0Hz Cooling method 90 110 132 160 200 220 280 315 15 18.5 22 150% DC injection braking Fan cooling -UL/cUL -CE Marking (Low Voltage) -EMC Directive -TÜV (up to 22kW) -EN 61800-2 (Ratings, specifications for low voltage adjustable frequency a.c. power drive systems) -EN 61800-3 (EMC product standard including specific test methods) Mass kg 2.2 2.5 3.8 3.8 3.8 6.5 6.5 10 10 10.5 10.5 31 31 36 41 42 50 73 73 104 104 145 145 VT: Variable torque NOTES: *1) Specifications for VT use are shown below. *2) Inverter output capacity (kVA) at 415V. *3) Output voltage is proportional to the power supply voltage and cannot exceed the power supply voltage. *4) Current derating may be required in case of low impedance loads such as high frequency motor. *5) When the input voltage is 380V/50Hz or 380 to 415V/60Hz, the top of the auxiliary transformer must be changed. *6) Refer to the EN 61800-3 (5.2.3). *7) Tested at standard load condition (85% load). *8) This value is calculated. (Refer to IMO). Jaguar VXM/09/08 37 30 – 17 380, 400, 415V/50Hz – 30 – – 150% of rated current for 1 min. 200% of rated current for 0.5s 110% HD - 60% LD Braking torque (Using options) CT: Constant torque – Voltage: +10 to -15% (Voltage unbalance *6): 2% or less) Rated current *8) (with DCR) Required power supply capacity (with DCR) – 1.0 1.7 2.6 3.9 6.4 9.3 12 V Short time (CT use) – 0.4 0.75 1.5 2.2 4.0 5.5 7.5 11 A Output frequency Braking – HD Phases, Voltage, Frequency Control 75 150 220 400 550 750 1100 1500 1850 2200G – – Rated current *4) Over Load Capability Input ratings 40 *9) With a nominal applied motor, this value is average torque when the motor decelerates and stops from 60Hz. (It may change according to motor loss.) *10) Input ratings given for HD use. Conformity to Low Voltage Directive The Jaguar VXM Series conforms to the Low Voltage Directive with EN50178. Conformity to EMC Directive • Emission requirement EMC filters in compliance with EN61800-3 are provided for all models as an optional extra • Immunity requirement The Jaguar VXM Series inverters meet EN61800-3 as standard. www.imopc.com High Performance AC Drives 0.4-400kW VXM continued Common specification Item Setting Output frequency Control Explanation Maximum frequency 50 to 400Hz *1) Base frequency 25 to 400Hz *1) Starting frequency 0.2 to 60Hz, Holding time: 0.0 to 10.0s Carrier frequency *2) HD use, heavy duty 0.75 to 15kHz (55kW or smaller) *3) 0.75 to 10kHz (75kW or larger) LD use light/normal duty 0.75 to 15kHz (22kW or smaller) 0.75 to 10kHz (30 to 75kW) 0.75 to 6kHz (90kW or larger) Accuracy (Stability) • Analog setting : ±0.2% of maximum frequency (at 25 ±10˚C) • Digital setting : ±0.01% of maximum frequency (at -10 to +50˚C) Setting resolution • Analog setting : 1/3000 of maximum frequency ex.) 0.02Hz at 60Hz, 0.04Hz at 120Hz, (0.15Hz at 400Hz : EN) • Digital setting : 0.01Hz at maximum frequency of up to 99.99Hz (0.1Hz at Maximum frequency of 100Hz and above) • LINK setting : 1/20000 of maximum frequency ex.) 0.003Hz at 60Hz, 0.006Hz at 120Hz, (0.02Hz at 400Hz : EN) • 0.01Hz (Fixed) Control method • V/f control (Sinusoidal PWM control) • Dynamic torque-vector control (Sinusoidal PWM control) • Vector control with PG (*) (EN only) Voltage/freq. (V/f) characteristic Adjustable at base and maximum frequency, with AVR control : 320 to 480V Torque boost Selectable by load characteristics: Constant torque load (Auto/manual), variable torque (manual) Operation method • KEYPAD operation : or key, key • Digital input signal operation : FWD or REV command, Coast-to-stop command, etc. • LINK operation : RS485 (Standard) Profibus-DP, Interbus-S, DeviceNet, Modbus Plus, CAN open (Option) Frequency setting (Frequency command) • KEYPAD operation : or key • External potentiometer (*) • Analog input (Reversible) (Inverse) : 1 to 5k (1/2W) : 0 to +10VDC (0 to +5VDC), 4 to 20mA DC 0 to ±10VDC (0 to ±5VDC) . . . Reversible operation by polarised signal can be selected. +10 to 0VDC, 20 to 4mA DC . . . Inverse mode operation can be selected. • UP/DOWN control : Output frequency increases when UP signal is ON, and decreases when DOWN signal is ON. • Multistep frequency : Up to 16 different frequencies can be selected by digital input signal. • Pulse train input (*) : 0 to 100kp/s • Digital signal (parallel) (*) : 16-bit binary • LINK operation • : RS485 (Standard) Profibus-DP, Interbus-S, DeviceNet, Modbus Plus, CAN open (Option) • Programmed PATTERN operation: Maximum 7 stages Jogging operation • Running status signal Transistor output (4 points) Acceleration/Deceleration time Active drive or key, FWD or REV digital input signal : RUN, FAR, FDT, OL, LU, TL, etc. Relay output (2 points) : Same as transistor output Analog output (1 point) : Output frequency, output current, output torque, etc. • Alarm output (for any fault) Pulse output (1 point) : Output frequency, output current, output torque, etc. 0.01 to 3600s : Independently adjustable acceleration and deceleration Mode select : Linear, S-curve (weak), S-curve (strong), Non-linear • 4 different times are selectable. When the acceleration time reaches 60s, the motor output torque is automatically reduced to rated torque. After 60s the motor operation mode is changed to torque limiting operation. The acceleration time is automatically extended up to 3 times. Frequency limiter High and low limiter can be preset. Bias frequency Bias frequency can be preset. Gain for frequency setting Gain for frequency setting can be preset (0.0 to 200.0%) frequency at 5VDC. ex.) Analog input 0 to +5VDC with 200% gain results in maximum Skip frequency control Skip frequency (3 points) and its common skip hysteresis width (0 to 30Hz) can be preset. Rotating motor pick up (Flying start) A rotating motor (including inverse rotating mode) can be smoothly picked up without stopping the motor (speed search method). Auto-restart after momentary power failure Automatic restart is available without stopping motor after a momentary power failure (speed search method). When “Smooth recovery” mode is selected, the motor speed drop is held minimum. (The inverter searches the motor speed and smoothly returns to setting frequency.) Line/Inverter changeover operation Controls the switching operation between line power and inverter. The inverter has internal sequence function. Slip compensation The inverter output frequency is controlled according to the load torque to keep motor speed constant. When the value is set at “0.00” and “Torque-vector” is set at “active”, the compensation value is automatically set. Slip compensation can be preset for the second motor. Droop operation The motor speed droops in proportional to output torque (-9.9 to 0.0Hz). Torque limiting • When the motor torque reaches a preset limiting level, this function automatically adjusts the output frequency to prevent the inverter from tripping due to an overcurrent. • Torque limiting 1 and 2 can be individually set, and are selectable with a digital input signal. Torque control Output torque (or load factor) can be controlled with an analog input signal. PID control This function can control flow rate pressure, etc. (with an analog feedback signal.) • Reference • KEYPAD operation ( or key): Setting freq./Max. freq. X 100 (%) • PATTERN operation : Setting freq./Max. freq. X 100 (%) signal • Voltage input (Terminal 12 and V2) : 0 to +10V DC • DI option input (*) : BCD, setting freq./Max. freq. X 100 (%) • Current input (Terminal C1) : 4 to 20mA DC • Binary, full scale/100 (%) • Reversible operation with polarity (Terminal 12) : 0 to ±10V DC • Multistep frequency setting : Setting freq./Max freq. X 100 (%) • Reversible operation with polarity (Terminal 12 + V1) : 0 to ±10V DC • RS485 : Setting freq./Max freq. X 100 (%) • Inverse mode operation (Terminal 12 and V2) : +10 to 0V DC • Inverse mode operation (Terminal C1) : 20 to 4mA DC • Feedback • Terminal 12 (0 to +10V DC or +10 to 0V DC) signal • Terminal C1 (4 to 20mA DC or 20 to 4mA DC) NOTES: (*) Option *1) For application at 120Hz or above, please contact IMO. *2) Inverter may automatically reduce carrier frequency, in accordance with ambient temperature or output current for protection purposes. *3) The minimum carrier frequency changes depending on maximum output frequency. Jaguar VXM/09/08 www.imopc.com High Performance AC Drives 0.4-400kW VXM continued Common specification continued Control Indication Item Explanation Automatic deceleration Torque limiter 1 (braking) is set at “F41:0” (Same as Torque limiter 2 (braking). • In deceleration : The deceleration time is automatically extended up to 3 times the setting time for tripless operation even if braking resistor not used. • In constant speed operation : Based on regenerative energy, the frequency is increased and tripless operation is active. Second motor’s setting This function is used for two motors switching operation. • The second motor’s V/f characteristics (base and maximum frequency) can be preset. • The second motor’s circuit parameter can be preset. Torque-vector control can be applied to both motors. Energy saving operation This function minimises inverter and motor losses at light load. Fan stop operation This function is used for silent operation or extending the fan’s lifetime. Universal DI Transmits to main controller of LINK operation. Universal DO Outputs command signal from main controller of LINK operation. Universal AO Outputs analog signal from main controller of LINK operation. Zero speed control (*) The motor speed is controlled with the speed reference of zero – (holding torque). Positioning control (*) The SY option card can be used for positioning control by differential counter method. Synchronised operation (*) The function controls the synchronised operation between 2 axes with encoders. Operating mode (Running) LED monitor • Output frequency 1 (before slip compensation) (Hz) • Output frequency 2 (after slip compensation) (Hz) • Setting frequency (Hz) • Output current (A) • Output voltage (V) • Motor synchronous speed (r/min) • Line speed (m/min) LCD monitor (English, German, French, Spanish, Italian, Japanese) Operation monitor and alarm monitor Operation monitor • Displays operation guidance • Bargraph: Output frequency (%), output current (A), output torque (%) Alarm monitor • The alarm data is displayed when the inverter trips. • Load shaft speed (r/min) • Torque calculation value (%) • Input power (kW) • PID reference value (“F01”) • PID reference value (Remote) (“C30”) • PID feedback value • Trip history: Cause of trip by code (even when main power supply is off, trip history data of the last 4 trips are retained). Stopping Trip mode Selected setting value or output value Displays the cause of trip by codes as follows. • OC1 (Overcurrent during acceleration) • OC2 (Overcurrent during deceleration) • OC3 (Overcurrent running at constant speed) • EF (Ground fault) • Lin (Input phase loss) • FUS (Fuse blown) • OU1 (Overvoltage during acceleration) • OU2 (Overvoltage during deceleration) • OU3 (Overvoltage running at constant speed) • LU (Undervoltage) • OH1 (Overheating at heat sink) • OH2 (External thermal relay tripped) • OH3 (Overtemperature of inside air) • dBH (Overheating of DB circuit) • OL1 (Motor 1 overload) • OL2 (Motor 2 overload) • OLU (Inverter unit overload) • OS (Overspeed) • PG (PG error) • Er1 (Memory error) • Er2 (KEYPAD panel communication error) • Er3 (CPU error) • Er4 (Option error) • Er5 (Option error) • Er7 (Output phase loss error, impedance imbalance) • Er8 (RS485 error) Charge lamp Jaguar VXM/09/08 Function setting and monitor Function setting Displays function codes and its data or data code, and changes the data value. Operation condition • Output frequency (Hz) • Motor synchronous speed (r/min) • Output current (A) • Load shaft speed (r/min) • Line speed (m/min) • Output voltage (V) • Torque calculation value (%)• PID reference value • Setting frequency (Hz) • PID feedback value • Operation condition • Driving torque limiter setting value (%) (FWD/REV, IL, VL/LU, TL) • Braking torque limiter setting value (%) Tester function (I/O check) • Digital I/O: (ON), (OFF) • Analog I/O: (V), (mA), (H), (p/s) Maintenance data • Operation time (h) • Cooling fan operation time (h) • DC link circuit voltage (V) • Communication error times • Temperature of inside air (˚C) (KEYPAD, RS485, Option) • Temperature of heat sink (˚C) • ROM version • Maximum current (A) (Inverter, KEYPAD, Option) • Main circuit capacitor life (%) • Control PC board life (h) Load factor calculation • Measurement time (s) • Average current (A) • Average braking power (%) • Maximum current (A) Alarm data • Output frequency (Hz) • Temperature of inside air (˚C) • Output current (A) • Heat sink temperature (˚C) • Output voltage (V) • Communication error times • Torque calculation value (%) (KEYPAD, RS485, Option) • Setting frequency (Hz) • Digital input terminal condition • Operation condition (Remote, communication) (FWD/REV, IL, VL/LU, TL) • Transistor output terminal condition • Operation time (h) • Trip history code • DC link circuit voltage (V) • Multiple alarm occurrence • When the DC link circuit voltage is higher than 50V, the charge lamp is ON. www.imopc.com High Performance AC Drives 0.4-400kW VXM continued Common specification continued Item Protection Explanation Overload Protects the inverter by electronic thermal and detection of inverter temperature. Overvoltage Detects DC link circuit overvoltage, and stops the inverter. Undervoltage Detects DC link circuit undervoltage, and stops the inverter. Input phase loss Phase loss protection for power line input. Overheating Protects the inverter by detection of inverter temperature. Short-circuit Short-circuit protection for inverter output circuit. Ground fault • Ground fault protection for inverter output circuit (3 phase current detection method). • Zero-phase current detection method (30kW or larger). Motor overload • Electronic thermal overload relay can be selected for standard motor or inverter rated motor. • Thermal time constant (0.5 to 75.0 minutes) can be preset for a special motor. • The second motor’s electronic thermal overload relay can be preset for 2-motor changeover operation. DB resistor overheating • Prevents DB resistor overheating by internal electronic thermal overload relay (7.5kW or smaller). • Prevents DB resistor overheating by external thermal overload relay attached to DB resistor (11kW or larger). (The inverter stops discharge operation to protect the DB resistor). Stall prevention • Controls the output frequency to prevent (overcurrent) trip when the output current exceeds the limit value during acceleration. • Lowers the output frequency to hold almost constant torque when the output current exceeds the limit value during operation at constant speed. • Controls the output frequency to prevent (overvoltage) trip when the DC link circuit voltage exceeds the limit value during deceleration. Output phase loss When the inverter executes auto-tuning, detects each phase impedance imbalance and displays an Error code. Motor protection by PTC thermistor When the motor temperature exceeds allowable value, the inverter trips automatically. Auto reset When the inverter is tripped it can be set to automatically reset and start. Condition Installation location (Installation Altitude and operation) Ambient temperature Ambient humidity Vibration Storage condition 400V series: 800VDC. 400V series: 400VDC. Free from corrosive gases, flammable gases, oil mist, dusts and direct sunlight. Indoor use only. 1000m or less. Applicable to 3000m with power derating (-10%/1000m). -10 to +50˚C. For inverters of 22kW or smaller, remove the ventilation covers when operating it at a temperature of 40˚C or above. 5 to 95%RH (non-condensing). 3mm from 2 to less than 9Hz, 9.8m/s2 from 9 to less than 20Hz 2m/s2 from 20 to less than 55Hz, 1m/s2 from 55 to less than 200Hz Temperature: -25 to +65˚C, Humidity: 5 to 95%RH (non-condensing) Basic wiring diagram Terminal arrangement • Main circuit terminals • Control circuit terminals VXM40 VXM75 VXM30KP VXM110K VXM150 VXM400 VXM132K VXM220K VXM550 VXM750 VXM1100 VXM2200G Jaguar VXM/09/08 www.imopc.com High Performance AC Drives 0.4-400kW VXM continued Terminal functions continued Main circuit Symbol Terminal name L1/R, L2/S, L3/T U, V, W P1, P(+) Power input Inverter output For DC REACTOR P(+), N(-) For BRAKING UNIT 12 For EXTERNAL BRAKING RESISTOR Grounding Auxiliary control power supply Potentiometer power supply Voltage input C1 (Torque control) (PID control) (PG feedback) Current input P(+), DB G R0, T0 Analog input Digital input 13 V2 11 FWD REV X1 X2 X3 X4 X5 X6 X7 X8 X9 (SS1) (SS2) (SS4) (SS8) (RT1) (RT2) (HLD) ACC/DEC time selection 3 wire operation stop command (BX) Coast-to-stop command (RST) Alarm reset Remarks Func. code Connect a 3 phase induction motor Connect the DC REACTOR for power-factor correcting or harmonic current reducing • Connect the BRAKING UNIT (option) DC REACTOR: Option BRAKING UNIT (Option): 11kW or larger Used for DC bus connection system Connect the EXTERNAL BRAKING RESISTOR (option) Only for 7.5kW or smaller Ground terminal for inverter chassis (housing) Connect the same AC power supply as that of the main circuit to back up the control circuit power supply 0.75kW or smaller: Not applicable +10VDC power supply for frequency setting POT (POT: 1 to 5k ) • Allowable maximum output current: 10mA • 0 to +10VDC/0 to 100% (0 to +5VDC/0 to 100%) • Reversible operation can be selected by function setting. 0 to ±10VDC/0 to ±100% (0 to ±5VDC/0 to ±100%) • Inverse mode operation can be selected by function setting or digital input signal +10 to 0VDC/0 to 100% Used for torque control reference signal Used for PID control reference signal or feedback signal Used for reference signal of PG feedback control (option) • 4 to 20mA DC/0 to 100% • Inverse mode operation can be selected by function setting or digital input signal. 20 to 4mA DC/0 to 100% • Input impedance: 22k • Allowable maximum input voltage: ±15VDC • If input voltage is 10 to 15VDC, the inverter estimates it to 10VDC Used for PID control reference signal or feedback signal The PTC-thermistor (for motor protection) can be connected to terminal C1-11 0 to +10VDC Common for analog signal FWD: ON . . . The motor runs in the forward direction FWD: OFF . . . The motor decelerates and stops REV: ON . . . The motor runs in the reverse direction REV: OFF . . . The motor decelerates and stops These terminals can be preset as follows F01, H21 Change over the PIN switch on control board (SW2: PTC) H26, H27 Can’t change over the terminal C1 F01 Isolated from terminal CMY and CM When FWD and REV are simultaneously ON, the F02 decelerates and stops • ON state maximum input voltage: 2V (maximum source current: 5mA) • OFF state maximum terminal voltage: 22 to 27V (allowable maximum leakage current: 0.5mA) E01 to E09 (SS1) : 2 (0,1) different frequencies are selectable (SS1, SS2) : 4 (0 to 3) different frequencies are selectable (SS1, SS2, SS4) : 8 (0 to 7) different frequencies are selectable (SS1, SS2, SS4, SS8) : 16 (0 to 15) different frequencies are selectable (RT1 : 2 (0, 1) different ACC/DEC times are selectable (RT1, RT2) : 4 (0 to 3) different ACC/DEC times are selectable Used for 3 wire operation (HLD): ON . . . The inverter self-holds FWD or REV signal (HLD): OFF . . . The inverter releases self-holding (BX): ON . . . Motor will coast-to-stop. (No alarm signal will be output) Frequency 0 is set by F01 (or C30) (All signals of SS1 to SS8 are OFF) C05 to C19 Time 0 is set by F07/F08 (All signals of RT1 to RT2 are OFF) Assigned to terminal X7 at factory setting F07, F08 E10 to E15 (RST): ON . . . Faults are reset. (This signal should be held for more than 0.1s) • Input impedance: 250k • Allowable maximum input current: 30mA DC • If input current is 20 to 30mA DC, the inverter estimates it to 20mA DC • The motor restarts from 0Hz by turning off BX with the operation command (FWD or REV) ON • Assigned to terminal X8 at factory setting • During normal operating, this signal is ignored • Assigned to X9 at factory setting (THR): OFF . . . “OH2 trip” occurs and motor will coast-to-stop This alarm signal is held internally (JOG) (JOG): ON . . . JOG frequency is effective (Hz2/Hz1) Freq. set 2/Freq. set 1 (Hz2/Hz1): ON . . . Freq. set 2 is effective (M2/M1) Motor 2/Motor 1 (DCBRK) DC brake command This signal is effective only while the inverter is stopped If this signal is changed while the inverter is running the signal is effective only after the inverter stops If this signal is changed while the inverter is running the signal is effective only after the inverter stops If the operation command (FWD/REV) is input while DC braking is effective, the operation command (FWD/REV) has priority (TL2/TL1) (SW50) (SW60) (UP) (DOWN) (WE-KP) (Hz/PID) (IVS) (IL) (Hz/TRQ) (LE) (U-DI) (STM) Torque limiter 2/ Torque limiter 1 Switching operation between line and inverter UP command DOWN command (M2/M1): ON . . . The motor circuit parameter and V/f characteristics are changed to the second motor’s ones (DCBRK): ON . . . The DC injection brake is effective. (In the inverter deceleration mode) H11 C20 C30/F01 A10 to A18/ P01 to P09 F20 to F22 E16, E17/ F40, F41 (TL2/TL1): ON . . . Torque limiter 2 is effective (SW50(SW60)): ON . . . The motor is changed from inverter operation to line operation (SW50(SW60)): OFF . . . The motor is changed from line operation to inverter operation (UP): ON . . . The output frequency increases (DOWN): ON . . . The output frequency decreases • The output frequency change rate is determined by ACC/DEC time • Restarting frequency can be selected from 0Hz or setting value at the time of stop Write enable for KEYPAD (WE-KP): ON . . . The data is changed by KEYPAD PID control cancel (Hz/PID): ON . . . The PID control is cancelled, and frequency setting by KEYPAD ( or ) is effective Inverse mode changeover (IVS): ON . . . Inverse mode is effective in analog signal input the signal is effective only after the inverter stops Interlock signal for 52-2 Connect to auxiliary contact (1NC) of 52-2 TRQ control cancel (Hz/TRQ): ON . . . The torque control is cancelled, and ordinary operation is effective Link enable (RS485, Bus) (LE): ON . . . The link operation is effective. Used to switch between manual operation and serial link auto mode Universal DI This signal is transmitted to main controller of LINK operation Pick up start mode (STM): ON . . . The “Pick up” start mode is effective F01, C30 H18 F01, H21 Trip command (External fault) Jogging operation (THR) Jaguar VXM/09/08 (PID control) (PTC-Thermistor input) Voltage input 2 Common Forward operation command Reverse operation command Digital input 1 Digital input 2 Digital input 3 Digital input 4 Digital input 5 Digital input 6 Digital input 7 Digital input 8 Digital input 9 Multistep freq. selection Function Connect a 3 phase power supply Main circuit changeover signals are output through Y1 to Y5 terminal When UP and DOWN commands are simultaneously ON, DOWN signal is effective F01, C30 F00 H20 to H25 If this signal is changed while the inverter is running RS485: Standard, Bus: option F01, C30 H18 H30 H09 www.imopc.com High Performance AC Drives 0.4-400kW VXM continued Terminal functions continued Digital input Symbol (PG/Hz) (SYC) (ZERO) (STOP 1) Terminal name SY-PG enabled Synchronised command Zero speed command Forced stop command (STOP 2) Forced stop command (STOP 2): OFF . . . The motor decelerates and stops with Deceleration time 4 with Deceleration time 4 Pre-exciting command (EXITE): ON . . . Motor magnetic flux is established before starting in PG vector mode PLC terminal Connect PLC power supply to avoid malfunction of the inverter that has SINK type digital input, when PLC power supply is off DC voltage supply DC voltage supply (+24V, maximum 100mA) Analog monitor Output voltage (0 to 10VDC) is proportional to selected function’s value as follows. The proportional coefficient and bias value can be preset. • Output frequency 1 (Before slip compensation) (0 to max. frequency) • Output frequency 2 (After slip compensation) (0 to max. frequency) (0 to 200%) • Output current • Output voltage (0 to 200%) • Output torque (0 to 200%) • Load factor (0 to 200%) • Input power (0 to 200%) • PID feedback value (0 to 100%) • PG feedback value (0 to max. speed) • DC link circuit voltage (0 to 1000V) (Common) • Universal AO (0 to 100%) Pulse rate monitor • Pulse rate mode: Pulse rate is proportional to selected function’s value* (50% duty pulse) • Average voltage mode: Average voltage is proportional to selected function’s value* (2670p/s pulse width control) (EXITE) PLC Analog output Pulse Output Transistor output P24 FMA (11) FMP (CM) CM Y1 Y2 Y3 Y4 (RUN) (FAR) (FDT1) (LU) (B/D) (TL) (IPF) (OL1) (KP) (STP) (RDY) (SW88) (SW52-2) (SW52-1) (SWM2) (AX) (TU) (TO) (STG1) (STG2) (STG4) (AL1) (AL2) (AL4) (AL8) (FAN) (TRY) (U-DO) (OH) (SY) (LIFE) (FDT2) (OL2) (C1OFF) (N-EX) CMY Relay output 30A, 30B 30C Y5A, Y5C Link DX+, DX-, SD Jaguar VXM/09/08 (Common) Common Transistor output 1 Transistor output 2 Transistor output 3 Transistor output 4 Inverter running Frequency equivalence signal Frequency level detection Undervoltage detection signal Torque polarity Torque limiting Auto-restarting Overload early warning Function (PG/Hz): ON . . . Synchronised operation or PG-feedback operation is effective (SYC): ON . . . The motor is controlled for synchronised operation between 2 axes with PGs (ZERO): ON . . . The motor speed is controlled with the speed reference of zero (STOP 1): OFF . . . The motor decelerates and stops • Function to be output is same as those of analog output (FMA) Common for pulse output Output the selected signals from the following items Remarks Option Option This function can be selected at PG feedback control. Option Func. code E15 Allowable maximum output current: 2mA F30 to F31 Allowable maximum output current: 2mA F33 to F35 Isolated from terminal CMY and 11 • ON state maximum output voltage: 3V (Allowable maximum sink current: 50mA) • OFF state maximum leakage current: 0.1mA (Allowable maximum voltage: 27V) Outputs ON signal when the output frequency is higher than starting frequency Outputs ON signal when the difference between output frequency and setting frequency is smaller than FAR hysteresis width Outputs ON signal by comparison of output frequency and preset value (level and hysteresis) E20 to E23 E30 E31, E32 Outputs ON signal when the inverter stops by undervoltage while the operation command is ON. Outputs ON signal in braking or stopping mode, and OFF signal in driving mode Output ON signal when the inverter is in torque-limiting mode Outputs ON signal during auto restart operation (Instantaneous power failure) mode. (Including “restart time”) • Outputs ON signal when the electronic thermal value is higher than preset alarm level • Outputs ON signal when the output current value is higher than preset alarm level KEYPAD operation mode Outputs ON signal when the inverter is in KEYPAD operation mode Inverter stopping Outputs ON signal when the inverter is in stopping mode or in DC braking mode Ready output Outputs ON signal when the inverter is ready for operation Line/Inv changeover Outputs 88’s ON signal for Line/Inverter changeover operation (for 88) Line/Inv changeover Outputs 52-2’s ON signal for Line/Inverter changeover operation (for 52-2) Line/Inv changeover Outputs 52-1’s ON signal for Line/Inverter changeover operation (for 52-1) Motor2/Motor1 Outputs the motor changeover switch ON signal from motor 1 to motor 2 Auxiliary terminal Used for auxiliary circuit of 52-1 (for 52-1) (Same function as AX1, AX2 terminal Jaguar VX series. (30kW or larger) Time-up signal Outputs time up signal (100ms ON pulse) at every stage end of PATTERN operation Cycle completion signal Outputs one cycle completion signal (100ms ON pulse) at PATTERN operation Stage No. indication 1 Outputs Pattern operation’s stage No. by signals STG1, STG2 and STG4 Stage No. indication 2 Stage No. indication 4 Alarm indication 1 Outputs trip alarm No. by signals AL1, AL2, AL4 and AL8 Alarm indication 2 Alarm indication 4 Alarm indication 8 Fan operation signal Outputs the inverter cooling fan operation status signal Auto-resetting Outputs ON signal at auto resetting mode. (Including “Reset interval”) Universal DO Outputs command signal from main controller of Link operation Overheat early warning Outputs ON signal when the heat sink temperature is higher than (trip level – 10˚C) and outputs OFF signal when the temperature is lower than (trip level – 15˚C) Synchronisation Synchronisation completion signal for synchronised operation completion signal Lifetime alarm Outputs ON signal when the calculated lifetime is longer than preset alarm level 2nd Freq. level 2nd outputs ON signal by comparison of output frequency and preset value (FDT2 level) detection 2nd OL level early 2nd outputs ON signal when the output current value is larger than preset alarm level warning (OL2 level) Terminal C1 off signal Outputs ON signal when the C1 current is smaller than 2mA Speed existence signal Outputs ON signal when motor speed is larger than stop speed* on vector control with PG Common (transistor Common for transistor output signal output) Alarm relay output Outputs a contact signal when a protective function is activated Changeable exciting mode active or non-exciting mode active by function “F36” Relay output Functions can be selected the same as Y1 to Y4 Changeable excitation mode active or non-excitation mode active by function “E25” RS485 I/O terminal Connect the RS485 link signal E33 to E35 F02 A01 to A18 Refer to wiring diagram example C21 to C28 H06 H04, H05 Option *stop speed = stop frequency (F25) x 120/pole (r/m) Isolated from terminals CM and 11 F25 • Contact rating: 250VAC, 0.3A, cosø=0.3 48VDC, 0.5A, non-inductive F36 E24 E25 www.imopc.com High Performance AC Drives 0.4-400kW VXM continued External signal input operation The following diagram is for reference only. For detailed wiring diagrams, refer to the relevant instruction manual. 7.5 kW or smaller 11 to 22 kW External braking resistor (DB) (*2) (*6) 2 (THR) 1 P DB G DC reactor (DCR) (*2) ( *9) Main circuit MCCB or ELCB ( *3) Power supply ( *1) 3-phase 400 to 480V 50/60Hz Auxiliary control power supply ( *7) Earth Potentiometer power supply (*2) ( *8) Earth Voltage input 2 0 to +10V DC ( + ) (0 to +5V DC) ( 0V ) or (+) Current input (-) 4 to 20mA Analog frequency meter (FM) 0 to 60Hz (*2) Analog input 3 2 1 (*4) P1 L1/R P(+) CNUX ( ) U1 U2 L2/S L3/T 2 1 P P G DB N (P24) Braking unit ( *2) ( *8) N(-) V W G G Control circuit +DC10V [13] [12] 0V [11] [V2] 30 [C1] [FMA] (P24) (PLC) < Y5C > < Y5A > (X1) (X2) (X3) < Y4 > < Y3 > < Y2 > < Y1 > < CMY > (X4) (X5) (X6) (X7) (X8) 50Hz Digital frepuency meter (pulse counter) (*2) (FMP) P(+) Pulse output (DX-) (DX+) RS485 interface port xx M Motor* (*8) G 2 DB N(-) 30 kW or larger External braking resistor (DB) (*2) (*6) 2 (THR) 1 P DB G P(+)R P(+) G Earth (*4) Alarm output (for any fault) (THR) (P24) 1 DB P(+) 2 DB 1 N(-) (P24) Braking unit ( *2) ( *8) N(-) NOTE: Common terminals [11], (CM), and <CMY> for control circuits are isolated from one another. (FWD) (X9) (CM) 30B 30C G +DC0~10V +DC24V 0V (REV) (CM) Digital input 30A P DBR (*5) U (R0) (T0) External braking resistor (DB) (*2) (*6) Relay output Transistor output Input voltage 400 to 440V/50Hz, 440 to 480V/60Hz 380V/50Hz (398V or smaller), 380 to 415V/60Hz (430V or smaller) CNUX connector U1 (Factory setting) U2 (SD) NOTE: *Option Digital inputs can be source or sink depending on position of switch SW1 on control PCB. Do not connect (P24) to (CM) as shown or damage may occur. *Option *1) Use the inverter whose rated input voltage matches the power supply voltage. *2) An optional device. Use it when necessary. *3) Use this peripheral device when necessary. *4) Terminals (P1) and (P(+)] are connected with a jumper wire before shipping. When connecting an optional DC reactor (DCR) *9), remove the jumper wire that connects the terminal (P1) and (P(+)]. *5) For models from 0.2 to 7.5kW, a built-in braking resistor (DBR) is connected to the inverter before shipping. (DBR is not mounted on models 11kW or larger.) When connecting an optional external braking resistor (DB), remove the DBR connection cables from (P(+)] and (DB) terminals. The end of the removed cables (indicated with an X) must be insulated. Jaguar VXM/09/08 *6) When connecting an optional external braking resistor (DB), be sure to also use an optional braking unit *8). Connect the optional braking unit to the (P(+)] and (N(-)] terminals. Auxiliary terminals (1) and (2) have polarity. Be sure to connect cables to these terminals correctly. (See the diagram). *7) Terminals (R0) and (T0) are provided for models 1.5kW or larger. These terminals are not provided for models 0.75kW or smaller. Even if these terminals are not powered, the invertor can be operated. *8) For EMC compliance it is necessary to use screened/armoured cable between inverter U, V, W terminals and the motor. The screen should be terminated to earth at both ends of the cable. The appropriate power supply filter kit may also be fitted to the inverter input circuit. For further details contact IMO. www.imopc.com High Performance AC Drives 0.4-400kW VXM continued Protective functions Function Description Overcurrent protection (Short-circuit) (Earth fault) • Stops running to protect inverter from an overcurrent resulting from overload. • Stops running to protect inverter from an overcurrent due to a short-circuit in the output circuit. LED monitor • Stops running to protect inverter from an overcurrent due to an earth fault in the output circuit. • Stops running to protect inverter from an overcurrent resulting from earth fault in the output circuit by detecting zero-phase current. During acceleration During deceleration While running at constant speed • 30kW or larger model only Earth Overvoltage protection • The inverter stops when it detects an overvoltage in the DC link circuit. • 400V series: 800VDC or more • Protection is not assured if excess AC line voltage is applied inadvertently. During acceleration During deceleration While running at constant speed Incoming surge protection • Protects the inverter against surge voltage between the main circuit power line and earth. • Protects the inverter against surge voltage in the main circuit power line. • The inverter may be tripped by some other protective function. Undervoltage protection • Stops the inverter when the DC link circuit voltage drops below undervoltage level. • 400V series : 400VDC or less • 200V series : 200VDC or less Input phase loss protection • The inverter is protected from being damaged when open-phase fault occurs. Overheat protection • Stops the inverter when it detects excess heat sink temperature in case of cooling fan failure or overload. • Stops the inverter when it detects an abnormal rise in temperature in the inverter unit caused by insufficient ventilation in cubicles or an abnormal ambient temperature. • Stops the inverter when it detects an abnormal rise in temperature inside the inverter. • When the built-in braking resistor overheats, the inverter stops discharging and running. • Function data appropriate for the resistor type (built-in/external) must be set. 7.5kW or smaller model only Electronic thermal overload relay (Motor protection) • This function stops the inverter by detecting an inverter overload. Fuse blown • When a blown fuse is detected, the inverter stops running. • 30kW or larger model only Stall prevention (Momentary overcurrent limitation) • When an output current exceeds the limit during acceleration, this function lowers output frequency to prevent an OC1 trip. • The stall prevention function can be disabled. Active drive • During running in which acceleration is 60s or longer, this function increases the acceleration time to prevent the occurrence of an OLU trip. • The acceleration time can be prolonged up to three times the preset time. External alarm input • The inverter stops on receiving external alarm signals. • Use THR terminal function (digital input). Overspeed protection • Stops the inverter when the output frequency exceeds the rated maximum frequency by 20%. PG error Alarm output if encoder (PG) signals are disconnected. Alarm output (for any fault) Alarm reset command • The inverter outputs a relay contact change over signal. • This function stops the inverter by detecting an overload in a standard motor or inverter motor. • An alarm-stop state of the inverter can be cleared with the RESET key or by a digital input signal (RST). Alarm history memory • Stores up to four previous alarm conditions. Storage of data on cause of trip • The inverter will store and display details of the latest alarm history data. Memory error • The inverter checks memory data after power-on and when the data is written. If a memory error is detected, the inverter trips. KEYPAD panel communication error • If an error is detected in communication between the inverter and KEYPAD when the Keypad panel is being used, the inverter trips. CPU error • If the inverter detects a CPU error caused by noise or some other factor, the inverter trips. Option communication error • If a checksum error or disconnection is detected during communication, the inverter issues an alarm. Option error • If a linkage error or other option error is detected, the inverter issues an alarm. Output phase loss error If an unbalance of output circuits is detected during auto-tuning, this function issues an alarm (and trips the inverter). RS485 communication error • If an RS485 communication error is detected, the inverter issues an alarm. NOTES: 1) Retaining alarm signal when auxiliary control power supply is not used: If the inverter power supply is cut off while an internal alarm signal is being output, the alarm signal cannot be retained. Jaguar VXM/09/08 Motor 1 overload Motor 2 overload • Output terminals: 30A, 30B and 30C • Use the RST terminal function for signal input. • Even if main power input is turned off, alarm history and trip-cause data are retained. • When operated by external signals, the inverter continues running. The alarm output (for any fault) is not output. Only Er2 is displayed. 2) To issue the RESET command, press the key on the KEYPAD panel or connect terminals RST and P24 and disconnect them afterwards. 3) Fault history data is stored for the past four trips. www.imopc.com High Performance AC Drives 0.4-400kW VXM continued External dimensions Fig 1 Fig 2 VXM40 VXM75 Type VXM40 VXM75 Fig 3 D 130 145 VXM550 VXM750 Jaguar VXM/09/08 VXM150 VXM400 D4 36.5 51.5 D5 80 95 Fig 4 VXM1100 VXM2200G www.imopc.com High Performance AC Drives 0.4-400kW VXM continued External dimensions continued Fig 5 Internal mounting type External cooling type (30kW (30kW or mounting larger) type larger) Internal Externalorcooling type (30kW or larger) (30kW or larger) 2 or 3 - øC D2 ø15 or ø18 Lifting hole D1 D D2 ø15 or ø18 Lifting hole H H1 H4 D H2 W1 D1 H5 W Fig 6 Keypad panel (common for all models) C Power supply voltage 400V Jaguar VXM/09/08 Nominal applied motor (kW) 30/37 37/45 45/55 55/75 75/90 90/110 110/132 132/160 160/200 200/220 220/280 280/315 315/355 4 or 6-Bolt H6 W2 W1 H1 4 or 6-Bolt H1 W1 Panel cutting H3 Panel drilling Dimensions (mm) C Mtg. Bolt 10 M8 15 M12 Type VXM30K/VXM30KP VXM37K VXM45K VXM55K VXM75K VXM90K VXM110K VXM132K VXM160K VXM200K VXM220K VXM280K VXM315K W 340 W1 240 W2 326 375 275 361 530 430 H H1 H2 H3 645 530 500 512 770 655 625 637 835 720 690 702 827.5 710 675 685 1087.5 970 935 945 1400 1370 1330 1340 H4 H5 H6 D 255 D1 12 25 9 270 145 315 175 360 220 450 285 4 510 32.5 680 580 D2 12.5 15.5 660 35 14.5 6.4 www.imopc.com High Performance AC Drives 0.4-400kW VXM continued Options EMC filters (typical) Fig. A Fig. B Fig. C Inverter type (and use) Filter required VXM40-75 RFM75FP Dimensions (mm) Rated Fig. current (A) 5 VXM150-400 RFM400FP 12 VXM550-750 RFM750FP 35 VXM1100-1500 RFM1500FP VXM1850-2200G RFM2200FP VXM30K (HD) -30KP H2 H3 D 116 90 310 293 265 W W1 H H1 10 42 45 155 105 310 293 265 10 225 167 331 311 260 10 47.5 50 250 185 480 449 400 20 72 250 185 480 449 400 20 70 RFM30K 100 200 166 435 408 – – 130 VXM30K (LD) -90K (HD) RFM90K 180 200 166 495 468 – – 160 VXM90K (LD) -132K (HD) RFM132K 280 250 170 587 560 – – 205 VXM132K (LD) -220K (HD) RFM220K 400 C 250 170 587 560 – – 205 VXM220K (LD) -315K 880 * 364 300 688 648 – – 180 RFM315K A B 70 * See Jaguar VXM instruction manual or contact IMO for details DC reactors (typical) Fig. A Power supply voltage Three phase 400V Fig. B Fig. C Nominal applied motor (kW) Reactor type Fig. A Typical mass B C D E F G 0.4 * A 66 56 72 90 60 35 5.2 x 8 94 M4 1.0 0.75 * A 66 56 72 90 60 40 5.2 x 8 94 M4 1.4 1.5 * A 66 56 72 90 60 45 5.2 x 8 94 M4 1.6 2.2 * A 86 71 80 100 65 45 6x9 110 M4 2.0 4.0 * A 86 71 80 100 70 50 6x9 110 M4 2.6 5.5 * A 86 71 80 100 70 50 6x9 110 M4 2.6 7.5 * A 111 95 80 100 75 60 7 x 11 130 M5 4.2 11 VXLC11 A 111 95 80 100 75 60 7 x 11 130 M5 4.3 15 VXLC15 A 146 124 96 120 75 60 7 x 11 171 M5 5.9 18.5 VXLC18 A 146 124 96 120 85 65 7 x 11 171 M6 7.2 22 VXLC22 A 146 124 96 120 85 65 7 x 11 171 M6 7.2 30 VXLC30 B 152 90 115 157 100 78 8 130 M8 13 37 VXLC37 B 171 110 110 150 100 75 8 150 M8 15 45 VXLC45 B 171 110 125 165 110 82 8 150 M8 18 55 VXLC55 B 171 110 130 170 110 85 8 150 M8 20 75 VXLC75 C 190 160 115 151 100 75 10 240 M10 20 90 VXLC90 C 190 160 125 161 120 80 10 250 ø12 23 110 VXLC110 C 190 160 125 161 120 80 10 250 ø12 25 132 VXLC132 C 200 170 135 171 120 85 10 260 ø12 28 160 VXLC160 C 210 180 135 171 120 85 12 290 ø12 32 200 VXLC200 C 210 180 135 171 140 90 12 295 ø12 35 220 VXLC220 C 220 190 135 171 140 90 12 300 ø15 40 280 VXLC280 C 220 190 145 181 150 95 12 320 ø15 45 315 VXLC315 Typical dimensions, mm H Terminal screw (kg) Available soon NOTE: (1) A DC reactor must be used for 75kW and above. (2) The above drawings, masses and dimensions are intended as a guide only. Product details may be subject to change without prior notice. If in doubt contact IMO Ltd. *Please contact IMO for details. Jaguar VXM/09/08 www.imopc.com High Performance AC Drives 0.4-400kW VXM continued Options continued Braking unit, braking resistor Inverter Power supply Constant Torque Rating (HD) Variable Torque Rating (LD) voltage Motor Inverter Motor Inverter (kW) type (kW) type Threephase 400V Option HD Braking Unit Braking resistor Type Qty (min) kW Max. braking torque (%) Continuous braking (100% torque conversion value) Braking time (s) Repetitive braking (100s or less cycle) Discharging capability (kWs) Duty cycle (%) Average loss (kW) 0.4 VXM40 – 1 200 0.2 45 9 22 0.044 0.75 VXM75 – 1 200 0.2 45 17 18 0.068 1.5 VXM150 – 1 160 0.4 45 34 10 0.075 – – LD Continuous braking (MAX. braking torque) Repetitive braking (100s or less cycle) Max. braking torque (%) Braking time (s) – – – – – Discharging Duty Average capability cycle loss (kWs) (%) (kW) 2.2 VXM220 – 1 160 0.4 30 33 7 0.077 4.0 VXM400 – 1 130 0.4 20 37 5 0.093 15 37 3.5 0.093 5.5 VXM550 7.5 VXM550 – 1 80 0.8 20 55 5 0.138 15 55 3.5 0.138 7.5 VXM750 11 VXM750 – 1 60 0.9 10 38 5 0.188 7 38 3.5 0.188 11 VXM1100 15 VXM1100 1 40 1.4 10 55 5 0.275 7 55 3.5 0.275 15 VXM1500 18.5 VXM1500 VXDBU 1 35 1.4 10 75 5 0.375 8 75 4 0.375 18.5 VXM1850 22 VXM1850 11-22 1 27 1.8 10 93 5 0.463 8 93 4 0.463 22 VXM2200G – – 1 22 1.8 0.55 – – 30 VXM30KP VXDBU 1 15 3.6 30 VXM30K 37 VXM30K 30-37 1 15 3.6 37 VXM37K 45 VXM37K 45 VXM45K 55 VXM45K 55 VXM55K 75 VXM55K 75 VXM75K 90 VXM75K VXDBU 45-55 VXDBU 150% – 100% 8 88 5 0.55 6 88 3 – – – – 10 150 10 1.5 10 150 10 1.5 10 150 10 1.5 1 12 4.8 10 185 10 1.85 10 185 10 1.85 1 10 6 10 225 10 2.25 10 225 10 2.25 1 7.5 7.2 1 6 9.6 100% 10 275 10 2.75 10 275 10 2.75 10 375 10 3.75 10 375 10 3.75 4.5 90 VXM90K 110 VXM90K 75-90 1 5 12 10 450 10 4.5 10 450 10 110 VXM110K 132 VXM110K VXDBU 1 3.75 14.4 10 550 10 5.5 10 550 10 5.5 132 VXM132K 160 VXM132K 110-132 1 3.33 18 10 660 10 6.6 10 660 10 6.6 160 VXM160K 200 VXM160K 200 VXM200K 220 VXM200K 220 VXM220K 280 VXM220K 280 VXM280K 315 VXM280K 315 VXM315K 400 VXM315K VXDBU 160-220 75% 1 3.0 19.2 10 800 10 8.0 10 800 10 8.0 1 2.5 24 10 1000 10 10.0 10 1000 10 10.0 1 1.88 28.8 10 1100 10 11.0 10 1100 10 11.0 Available soon NOTE: The braking time and duty cycle (%) are calculated as the constant-torque braking used for deceleration. 100% Braking power T1 • Duty cycle (%) = T0 x 100[%] Braking time T1 Braking interval T0 Braking time T1 (Procedure for selecting options) All three conditions listed below must be satisfied. 1. The maximum braking torque does not exceed the value shown in the table. 2. The energy discharged in the resistor for each braking (the area of the triangle shown in the above figure) does not exceed the discharging capability (kWs) in the table. 3. The average loss (energy discharged in the resistor divided by a braking interval) does not exceed the average loss (kW) shown in the table. Jaguar VXM/09/08 www.imopc.com High Performance AC Drives 0.4-400kW VXM continued Options continued Braking unit Fig.A Fig.B Fig. A Fig.C Fig. B 10 40 30 5 5 5 165 1.5 Fig. C Mounting hole H2 H1 H H D 1.2 W1 W 6 15 7.5 6 15 7.5 W1 W 4.5 5 30 21.5 91 N.P H2 H1 160 170 φ4.5 D D1 Dimensions (mm) Voltage Type 400V VXDBU 11-22 VXDBU 30-37 VXDBU 45-55 W Series Mass (kg) Fig. VXDBU 75-90 VXDBU 110-132 VXDBU 160-220 A B W1 H H1 H2 D See Fig. A 150 100 230 130 250 150 C 280 265 250 160 370 355 340 450 435 420 D1 – – 1.1 4 1.2 5.5 2.4 9 13 Braking resistors (typical combinations for heavier duty applications) Example 1 – DBR160R380W Covers: VXM150 VXM400 160Ω 380W Covers: VXM550 VXM750 80Ω 760W Covers: VXM1100 VXM2200G 40Ω 1520W Example 2 – DBR150R220W Covers: Jaguar VXM/09/08 VXM40 VXM75 150Ω 220W www.imopc.com High Performance AC Drives 0.4-400kW VXM continued Option Cards and other Options Name (type) Function Relay output card (VXMROC) • Includes four relay output circuits. • Converts transistor output signals from inverter control output terminals Y1 to Y4 to relay (1SPDT) output signals. Specifications Digital I/O interface card (VXMDI0) • For setting frequency using a binary code. • For monitoring frequency, output current and output voltage using a binary code. • For input and output of other individual signals. Analog I/O interface card (VXMAI0) • For setting a torque limit value using an input analog signal. • For input of auxiliary signal to set frequency. • For analog monitoring of inverter output frequency, output current and torque. T-link interface card (OPC-G11S-TL) • For setting a frequency. • For setting and reading function data for function codes. • For setting operation commands (FWD, REV, RST, etc.). • For monitoring the operation status. • For reading trip information. • Used together with MICREX-F series PLC. PG feedback card (VXMEFC) • For performing PG vector control using feedback signals obtained from an encoder. • Applicable Pulse Encoder specification: • 100 to 3000P/R • A, B, Z phase • 12V or 15V Synchronised operation card (VXMSYN) • Wait and synchronise mode, simultaneous start and synchronising mode. • Proportional speed operation. • Speed control by pulse train input can be made. Extension cable for keypad (VXPODCABLE) Connects the keypad panel to an inverter unit. Three cable types are available: straight 2m, curled 1m and curled 2m. The curled 1m cable can be extended up to 5m, and the curled 2m cable up to 10m. Note: Cables once extended to the maximum length do not return to their original length. Type Copy unit (VXMCOPY) • For batch data transfer (read, store, write) between an inverter unit and the copy unit. • For comparison of data stored in an inverter and data stored in the copy unit. • For comparison of two sets of data stored in the copy unit. • For editing a part of the data stored in an inverter. • Write protection is available in copy mode and edit mode. • The copy unit can write data to inverter memory even though the inverter is not connected to power source. Application • Copying • Vertification • Editing • Write protect IP20 enclosure adaptor • Used to put 30kW or larger models to increase enclosure rating from IP00 to IP20. Type Applicable inverter type P20G11-30 VXM30K VXM30KP P20G11-55 VXM37K to VXM55K Nominal length Maximum length VXPODCABLE 2m 2m CONTACT IMO 1m 5m CONTACT IMO 2m 10m P20G11-75-4 VXM75K P20G11-75-2 Not Available Mounting adaptor for external cooling Panel-mount adaptor (MAG9- ) Jaguar VXM/09/08 • Used to put the cooling fan section of the inverter outside the panel. • Only applicable to 22kW and below inverters. (30kW and above inverters can be modified to external cooling type by replacing the mounting bracket, as standard.) Used to mount a Jaguar VXM inverter in panel holes that were used to mount a Fuji G7S inverter. P20G11-110 VXM90K to VXM110K P20G11-160 VXM132K to VXM160K P20G11-220 VXM200K to VXM220K Type Applicable inverter type PBG11-0.75 VXM40 to VXM75 PBG11-3.7 VXM150 to VXM400 PBG11-7.5 VXM550 to VXM750 PBG11-22 VXM1100to VXM2200G Type Applicable inverter type MAG9-3.7 VXM40 to VXM400 MAG9-7.5 VXM550 to VXM750 MAG9-22 VXM1100 to VXM2200G www.imopc.com High Performance AC Drives 0.4-400kW VXM continued Wiring equipment Power supply voltage Three phase 400V MCCB or ELCB Rated current (A) Inverter type Nominal applied motor (kW) Heavy Duty Rating (HD) Light Duty Rating (LD) 0.4 VXM40 – 0.75 VXM75 – 1.5 VXM150 – 2.2 VXM220 – 4.0 VXM400 – 5.5 VXM550 7.5 VXM750 With DCR 6 10 16 – 16 20 VXM550 20 32 32 11 VXM1100 VXM750 VXM1500 VXM1100 18.5 VXM1850 VXM1500 22 VXM2200G VXM1850 50 75 30 VXM30K VXM30KP 37 VXM37K VXM30K 45 VXM45K VXM37K 55 VXM55K VXM45K 40 100 125 75 VXM75K VXM55K 175 90 VXM90K VXM75K 200 110 VXM110K VXM90K 225 132 VXM132K VXM110K 300 160 VXM160K VXM132K 350 200 VXM200K VXM160K 400 220 VXM220K VXM200K 500 280 VXM280K VXM220K 600 315 VXM315K VXM280K With DCR MC14-S-10 Without reactor MC2 for output circuit With DCR MC14-S-10 MC14-S-10 1.5 Without reactor Output circuit (U.V.W.) HD LD DCR circuit (P1,P(+)) MC24-S-00 MC24-S-00 MC24-S-00 40 MC32-S-00 MC32-S-00 MC32-S-00 50 MC40-S-00 MC40-S-00 MC40-S-00 MC50-S-00 MC50-S-00 MC50-S-00 100 MC62-S-00 MC62-S-00 MC62-S-00 125 MC74-S-00 MC74-S-00 MC74-S-00 60 75 1.5 1.5 – 1.5 2.5 2.5 2.5 2.5 DB circuit (P(+),DB,N(-)) 4 6 10 16 1.5 4 6 10 16 25 35 2.5 4 6 10 16 4 6 10 16 25 4 6 10 16 150 K110A22 K110A22 K110A22 25 50 25 35 25 175 K3150A11 K3150A11 K3150A11 35 70 35 50 35 K3150A11 K3150A11 K3175A11 K3175A11 – K3315A11 K3450A22 K3700A22 VXM315K NOTES: • For moulded-case circuit breakers (MCCB) and earth-leakage circuit breakers (ELCB), the required frame type and series depend on the transformer capacity and other factors. When selecting breakers, refer to IMO, if uncertain. • Select the current sensitivity of ELCB, with reference to motor cable length and type, and carrier frequency. • The recommended cable sizes are based on the condition that the temperature inside the panel does not exceeds 50˚C. Jaguar VXM/09/08 Recommended wire size (mm2) Input circuit (L1/R, L2/S, L3/T) 6 10 15 400 Without reactor Magnetic contactor (MC) MC1 for input circuit – K3315A11 K3450A22 K3700A22 50 50 70 50 70 70 95 70 95 95 120 95 120 120 150 120 150 240 185 240 300 300 400 400 – 185 300 500 – 300 2.5 4 6 10 16 25 500 Available soon • The above are 600V PVC insulated (75˚C). • Data in the above table may differ for different conditions (ambient temperature, power supply voltage and other factors). Caution: • If in doubt, consult local/national wiring regulations such as the relevant IEE Wiring Regulations - latest edition. www.imopc.com Jaguar VXG Series R TE YEA 3Ø, 400V/50~60Hz, 0.4~630kW (CT) 3Ø, 400V/50~60Hz, 0.4~710kW (VT) E High Performance Dual Rated AC Variable Speed Drives GUARAN User configurable quick-start menu IP20 side-by-side mounting (IP40) Intergrated EMC filter (EN61800-3 2004 cat C3) PLC logic type function RoHS, CE, UL,cUL compliant V/F, Torque Vector and closed loop control 200% starting torque between 0.3Hz Improved open-loop low-speed stability Enable input safety switch Mechanical brake control output - torque generated PID with Dancer control PTC thermistor input Input and Output phase-loss protection Loss-of-command signal detection Thermostatically operated long-life cooling fans (designed to operate for 10 years at 40oC) Life time / service due alarm output Standard Keypad with mini USB port. Optional multi-function back-lit keypad with parameter COPY mode Encoder feedback (close-loop) and shaft-synchronizing options Synchronous (Permanent Magnet) motor options Internal brake chopper up to 22kW (30-110kW upon request) JAGVXG/04/10 www.imopc.com Jaguar_VXG_data sheet.pdf 10/11/2011 12:38:51 PM Jaguar VXG Series continued Options and ordering codes VXG C M Y CM MY CY CMY K 60AL - CT Rating VT Rating 0.4kW - 1A5 0.75kW 1.5kW 2.2kW 4.0kW 5.5kW 7.5kW 11kW 15kW 18.5kW 22kW 30kW 37kW 45kW 55kW 75kW 90kW 110kW 132kW 160kW 200kW 220kW 280kW 315kW 355kW 400kW 500kW 630kW 7.5kW 11kW 15kW 18.5kW 22kW 30kW 37kW 45kW 55kW 75kW 90kW 110kW 132kW 160kW 200kW 220kW 280kW 315kW 355kW 400kW 500kW 630kW 710kW 2A5 4A 5.5A 9A 16A5L 23AL 30A5L 37AL 45AL 60AL A 75AL 91AL 112AL 150AL 176AL 210AL 253AL 304AL 377AL 415AL 520AL A 650AL 4 E E 2 4 Input voltage 200v/3ph* Input voltage 400v/3ph Power and Control Connections DBR *6 P(+) DCR *5 CM THR P1 MCCB or RCD/ELCB *1 *2 MC *13 FUSE Power supply P1 P DB [ ] P(+) DBR L1/R 400 V class series 380 to 480 V 50/60 Hz Main circuit DB N(-) U + L2/S Auxiliary fan power input *4 G 960AL 1170AL 3 2 1 13 +10 VDC 0V 12 11 Voltage input for frequency setting 0 to s 10 VDC (+) (-) V2 Current input for frequency setting 4 to 20 mA DC (+) (-) C1 30 0V EN1 0 to 10 VDC 4 to 20 mA DC EN2 SINK 0 to 10 VDC 4 to 20 mA DC PLC SW1 *11 *9 SOURCE Run forward command Run reverse command Select multi-frequency (0 to 1 step) Select multi-frequency (0 to 3 step) Select multi-frequency (0 to 7 step) Select multi-frequency (0 to 15 step) Select ACC/DEC time (2 steps) Select ACC/DEC time (4 steps) Reset alarm Contact outputs *9 Alarm output (for any alarm) Y5C Y5A AX terminal function Transistor outputs *9 Motor overload early warning Frequency/speed detected Frequency/speed arrival Inverter running Common terminal PLC *12 Digital input *8 30C 30B 30A Y4 Y3 Y2 Y1 CMY PTC/NTC SW5 *11 +24 VDC Safety relay module complying with more than EN954-1/EN ISO13849-1 Cat.3 *Special order only Grounding terminal *7 G Control circuit Analog input Potentiometer power supply Voltage input for frequency setting 0 to +10 VDC (0 to s 10 VDC) 840AL 3 - Power switching connector (CN UX) *10 - Fan power supply switching connector (CN R )/(CN W) *10 R1 T1 Grounding terminal M W R0 T0 Auxiliary control power input *3 Motor V L3/T 740AL 1370AL Integrated EMC filter FM1 SW4 *11 Analog frequency meter 11 Analog frequency meter FM2 SW6 *11 FWD DX+ DX- REV X1 X2 X3 X4 X5 X6 X7 CM 11 Data transmission SW2 SD *11 RS-485 COM port 2 (TB) RS-485 COM port 1 (RJ-45 connector for keypad) DBR DCR RCD : Dynamic Braking Resistor : DC Reactor : Residual-current-operated protective device ELCB : Earth Leakage Circuit Breaker MC : Magnetic Contactor MCCB : Molded Case Circuit Breaker JAGVXG/04/10 SW3 *11 USB connector www.imopc.com Jaguar VXG Series continued Specifications and Dimensions Three Phase 400V Power supply voltage JAGVXG/04/10 Motor Rating (CT) Motor Rating (VT) VXG1A5-4E VXG2A5-4E VXG4A-4E VXG5.5A-4E VXG9A-4E VXG16A5L-4E VXG23AL-4E VXG30A5L-4E VXG37AL-4E VXG45AL-4E VXG60AL-4E VXG75AL-4E VXG91AL-4E VXG112AL-4E VXG150AL-4E VXG176AL-4E VXG210AL-4E 0.4 0.75 1.5 2.2 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 7.5 11 15 18.5 22 30 37 45 55 75 90 110 VXG253AL-4E VXG304AL-4E VXG377AL-4E VXG415AL-4E VXG520AL-4E 110 132 160 200 220 132 160 200 220 280 VXG650AL-4E VXG740AL-4E VXG840AL-4E VXG960AL-4E VXG1170AL-4E VXG1370AL-4E 280 315 355 400 500 630 315 355 400 500 630 710 Inverter type Main body external dimensions (mm) Width Height 130 110 150 Depth 145 260 220 195 250 400 326.2 550 261.3 361.2 615 675 276.3 535.8 740 321.3 536.4 1000 366.3 1400 440 1550 500 686.4 880 1000 www.imopc.com Jaguar VXR Series E TE YEA R GUARAN R TE YEA 1Ø, 230V/50~60Hz, 0.4~2.2kW (½~3HP) 3Ø, 230V/50~60Hz, 0.4~15kW (½~20HP)* 3Ø, 400V/50~60Hz, 0.4~15kW (½~20HP) E Mechanical Handling / General Purpose AC Variable Speed Drives GUARAN z IP20 side-by-side mounting z Optional integrated EMI filtered models z Fast response to dynamic load changes - 64MHz CPU z RoHS, CE, UL/cUL compliant z V/F or Dynamic Torque Vector control z >300% starting torque between 1-3Hz z Improved open-loop low-speed stability z ‘Hit-and-Stop’ control with holding torque z Mechanical brake control output – torque generated z PID with ‘Dancer’ control z PTC thermistor input z Input and Output phase-loss protection z Loss-of-command signal detection z Thermostatically operated long-life cooling fans (designed to operate for 10 years at 40ºC) z Life time / service due alarm output z RS485 (RJ-45 IN/OUT) / Profibus / DeviceNet option cards z Optional multi-function back-lit keypad with parameter COPY mode z Encoder feedback (close-loop) and shaft-synchronizing options z Synchronous (Permanent Magnet) motor options*** z Internal brake chopper * Special order *** Available soon actualsize Options and ordering codes VXR Maximum continuous output current (A) 3A7 - 1A5 2A5 3A JAGVXR/01/09 4 3A7 5A 5A5 8A 9A 11A 13A 17A 13A 18A 24A 33A 47A 60A E E 1 4 2 No filter Integrated EMC filter Input voltage 230v/1ph Input voltage 400v/3ph Input voltage 200v/3ph www.imopc.com Jaguar VXR Series continued PowerandControl Connections Specificationsand Dimensions AllModels: z Overload (A) = 150% for 60s, 200% for 0.5s z Maximum operating temperature = 50ºC z Maximum output frequency = 400Hz z Carrier frequency = 0.75~15kHz Frame H(mm) H(ins) W(mm) W(ins) 1 120 4.72 80 3.15 2 130 5.12 110 4.33 3 180 7.09 140 5.51 4 220 8.66 180 7.09 5 260 10.24 220 8.66 Part Number VXR… Motor rating (kW) Motor rating (H.P) Rated output current (A) Frame size Depth (mm) Depth (inches) 1A5-4 0.37/0.55 0.5 1.5 2 126 4.96 1A5-4E 0.37/0.55 0.5 1.5 2 169 6.65 3-phaseinput380-480+10%-15%50/60Hz±5% 2A5-4 2A5-4E 3A7-4 3A7-4E 0.75/1.1 0.75/1.1 1.5 1.5 1 1 2 2 2.5 2.5 3.7 3.7 2 2 2 3 150 193 150 194 5.91 7.60 5.91 7.64 5A5-4 2.2 3 5.5 3 150 5.91 5A5-4E 2.2 3 5.5 3 194 7.64 Part Number VXR… Motor rating (kW) Motor rating (H.P) Rated output current (A) Frame size Depth (mm) Depth (inches) 3A-1 0.37/0.55 0.5 3 (2.5) 1 127 4.99 3A-1E 0.37/0.55 0.5 3 (2.5) 1 127 4.99 1-phaseinput200-240V±10%50/60Hz±5% 5A-1 5A-1E 8A-1 8A-1E 0.75/1.1 0.75/1.1 1.5 1.5 1 1 2 2 5 (4.2) 5 (4.2) 8 (7) 8(7) 1 2 2 3 152 150 160 194 5.98 5.91 6.30 7.64 11A-1 2.2 3 11 (10) 3 151 5.94 11A-1E 2.2 3 11 (10) 3 194 7.64 Part Number VXR… Motor rating (kW) Motor rating (H.P) Rated output current (A) Frame size Depth (mm) Depth (inches) 9A-4 4 5 9 3 151 5.94 9A-4E 4 5 9 3 194 7.64 JAGVXR/01/09 13A-4 5.5 7.5 13 4 158 6.22 3-phaseinput380-480V+10%-15%50/60Hz±5% 13A-4E 18A-4 18A-4E 24A-4 24A-4E 5.5 7.5 7.5 11 11 7.5 10 10 5 5 13 18 18 24 24 4 4 4 5 5 158** 158 158** 195 195** 6.22 6.22 6.22 7.68 7.68 30A-4 15 20 30 5 195 7.68 30A-4E 15 20 30 5 195** 7.68 www.imopc.com