Overview Lighting Control Overview RTC • Inbuilt real time clock • Automatic daylight savings adjustment • Atomic clock synchronisation (NTS). Triggers Inputs Schedules Network Conigurable inputs with dynamic modes and multistaged override timers for: • Automatic time based events • Touch screen • Sunrise and sunset with offset • Computer with building monitor • Push buttons and switches • Repeat timers • Linked controllers • Daylight sensors • Linked timers with offset • PDAs/smartphones • Occupancy sensors • Holidays and holiday schedules. • SMS (text messages). Direct Arc Level DALI Commands Extended Commands • Direct ARC power control • Dimming commands: Min, Max, etc. • Conditional commands: Min_If_On, etc • Logarithmic dimming curve with an arc power level of 0.1% to 100%. • Scenes with individual light levels • Controller commands • Status reporting • Timed sequences. • RF receivers, etc. Actions • Coniguration. Control Targets CLIPCOM 21240 May 2010 3001 Ballasts Groups Broadcast Outputs Up to 64 ballasts (1 loop) or up to 128 ballasts (2 loops). Up to 16 DALI Groups per loop + 48 extended Groups per loop. Single loop or all loops. 8 onboard outputs to drive relays. © Copyright Clipsal Australia Pty Ltd. The identified trademarks and copyrights are the property of Clipsal Australia Pty Ltd unless otherwise noted. www.dalicontrol.com Schematic Simple DALI Room Control Schematic 64 Addresses (max.) per DALI Loop (max. 300m) DALI-01 DALI Power Supply 250mA max. DALI Light Fittings 00 01 02 03 04 05 06 07 Optional Ethernet Controller/Gateway with RTC and I/O DALI Wallplate DALI Light Sensor DALI Occupancy Sensor DALI Wallplate Notes: • DALI is an international standard lighting control system. The schematic diagram shows a DALI network (DALI-01) powered by a DALI power supply. • DALI ECGs are available for FL and CFL lamps, discharge lamps, low voltage halogen lamps, incandescent lamps, LEDs, emergency lights, etc. • The eight light fittings (addressed from 00 to 07) can be any light fitting from any manufacturer fitted with DALI ECG (electronic control gear). • The light fittings are controlled by DALI ECDs (electronic control devices) such as DALI wallplates and DALI sensors from any manufacturer, including DALI control’s DC100 Series of DALI control devices. CLIPCOM 21240 May 2010 1011 • DALI can also control legacy light fittings including fixed output, analogue 1 to 10V and DSI dimmable fittings. © Copyright Clipsal Australia Pty Ltd. The identified trademarks and copyrights are the property of Clipsal Australia Pty Ltd unless otherwise noted. www.dalicontrol.com Schematic Floor Control Schematic 64 Addresses (max.) per DALI Loop (max. 300m) DALI Power Supply 250mA max. DALI-01 EXIT DCDALxx-xx DCDALCI 00 01 02 03 04 05 DALI EMG (06) 63 DCBM DALI Line Controller Occupancy and/or Light Sensor Ethernet Wallplate and Sensors Wallplate To Riser or Hub for Optional Computer Monitoring and Control To Security or Access Control Panel DCDALCI DALI Power Supply 250mA max. DALI-02 EXIT 00 DALI EMG (60) 01 02 03 04 63 DALI EMG (61) DALI Sensor DALI Wallplate Notes: • The controller manages up to two DALI networks. The controller includes scheduling, digital inputs, digital outputs and an RJ45 Ethernet network socket for computer monitoring and control. CLIPCOM 21240 May 2010 1012 • Inputs on the controller can be used for wallplates, sensors and interfacing to security and access control panels, etc. • The controller manages a DALI group based on inputs from standard switches and sensors. • Each DALI network requires a DALI power supply and a DALI interface. © Copyright Clipsal Australia Pty Ltd. The identified trademarks and copyrights are the property of Clipsal Australia Pty Ltd unless otherwise noted. www.dalicontrol.com Schematic Building Control Schematic Riser to Higher Floors 64 Addresses (max.) per DALI Loop, 00 to 63 64 Addresses (max.) per DALI Loop, 00 to 63 DALI-11 DALI-13 EXIT 03 00 01 02 EXIT 03 00 63 01 Wallplate and Sensors 02 63 Wallplate and Sensors To Master Override Switch Switchboard To Security/Access Control Panel DALI-14 DALI-12 EXIT 03 EXIT 03 00 01 02 00 63 01 02 DCDALxx-xx 63 DALI EMG (61) DALI Sensor DALI Wallplate Ethernet DALI Area Controller with Wallplate and Sensors Riser to Lower Floors Notes: • The controller manages up to two DALI networks and includes scheduling, digital inputs, digital outputs and an RJ45 Ethernet socket for computer monitoring and control. CLIPCOM 21240 May 2010 1013 • The switchboard contains controller/gateways, DALI power supplies and DALI interfaces. © Copyright Clipsal Australia Pty Ltd. The identified trademarks and copyrights are the property of Clipsal Australia Pty Ltd unless otherwise noted. www.dalicontrol.com Schematic Typical Switchboard Schematic Switchboard Riser to Control Room DALI Networks DALI-01 DCDALPSxxx EXIT DCDALCI DCDALCI 00 01 02 63 Wallplate DALI-02 DCDALPSxxx EXIT 00 01 02 63 Ethernet Switch Wallplate DALI-03 DCDALPSxxx EXIT DCDALCI DCDALCI 00 01 02 63 Wallplate DALI-04 DCDALPSxxx EXIT 00 01 02 63 Wallplate Notes: DALI-05 DCDALPSxxx • The controller manages up to two DALI networks. Each controller includes scheduling, inputs, outputs and an RJ45 Ethernet socket for computer monitoring and control. EXIT DCDALCI DCDALCI 00 01 02 63 Wallplate DALI-06 DCDALPSxxx EXIT 00 Wallplate CLIPCOM 21240 May 2010 1015 01 02 63 • Each DALI network requires a power supply and an interface. • Power supplies for the controller and Ethernet switch are not shown in the schematic diagram. Refer to wiring diagrams for full details. © Copyright Clipsal Australia Pty Ltd. The identified trademarks and copyrights are the property of Clipsal Australia Pty Ltd unless otherwise noted. www.dalicontrol.com Wiring BM-DALI Controller Wiring Overview To CCT Breaker Starter Socket Socket or T-Piece LL N N DA DALI-A DA DALI ECG (Addr 0) DCDAL10-0402 DCDAL0-02 DALI EMG (Addr 4) +V DALI Controllers Including: DALI Wallplates, Occupancy Sensors, Light Sensors, Group Controllers, Scene Controllers Touch Screens, etc. To DALI-B DCDALCI DC IN GND Notes: DCDALCI BMxxxx-DALI LINE CONTROLLER INPUTS 0..15 -V DALI ECG (Addr 63) DALI EMG (Addr 2) DCDALP250 or DCDALP200 DCDALP250 or DCDALP200 DALI ECG (Addr 3) EXIT SWITCHBOARD DCPxx/xx DALI ECG (Addr 1) • The diagram depicts a typical wiring layout for a DALI line. To Switches and Push Buttons, Occupancy and Light Sensors, Security and Access Control Panels, etc. • The DCPxx/xx power supply provides d.c. power for BM-DALI line controllers and for sensors connected to BM-DALI inputs. • The DCDALP200 or DCDALP250 are current limited, DIN rail mount DALI power supplies. • One DCDALP200 or DCDALP250 is required per DALI line. DC IN - • The DCDALCI is the DALI communications interface for the BM-DALI line controller. CAT5e or CAT6 + BUILDING MONITOR Ethernet Switch • One DCDALCI is required per DALI line. • Each DALI line can support up to 64 DALI ECG’s addressed from 0 to 63. • DALI ECGs are available for FL and CFL lamps, LV halogen, HID, LEDs, emergency fittings, fixed output, DSI and 1 to 10V analogue fittings, etc. • The computer and other Ethernet equipment is optional and can be used to monitor and control the system. DCLCD35 Control Panel or DCLCD70 Touch Panel CLIPCOM 21240 May 2010 2001 Ethernet Network to Computers, Touch Screens, LCD Control Panels and BM-DALI Network Controllers • DALI lines must be wired to the DALI standard and to local regulations. © Copyright Clipsal Australia Pty Ltd. The identified trademarks and copyrights are the property of Clipsal Australia Pty Ltd unless otherwise noted. www.dalicontrol.com Wiring BM-DALI Controller Digital Outputs + 2 1 2 1 4 3 4 3 6 5 6 5 7 8 7 8 12V DC Power Supply DCBM DALI Line Controller Plug Relay and Base (typical H72 x W28 x D67mm each base) Notes: Output Circuit • The DCBM DALI line controller has eight internal digital outputs; OUT 0 to OUT 7. Each output can sink 200mA. +K Load OUT/AUX + - External Power Suppy • When using the digital outputs to switch inductive loads it may be necessary to power K with a separate power supply. • Relay base terminals (arrangement shown is for PTF08A): 1. Contact 1 Normally Closed 2. Contact 1 Normally Open 3. Contact 1 Common 4. Contact 2 Normally Closed 5. Contact 2 Normally Open GND Internal Circuit External Components 6. Contact 2 Common 7. Coil 8. Coil CLIPCOM 21240 May 2010 2003 © Copyright Clipsal Australia Pty Ltd. The identified trademarks and copyrights are the property of Clipsal Australia Pty Ltd unless otherwise noted. www.dalicontrol.com Wiring DCBM-DALI Line Controller Ethernet Overview Administration Computer (optional) Ethernet Switch Level xyz Distribution Board Ethernet Switch BUILDING MONITOR DCBM-DALI Line Controller CAT5e Cable DCDALCI DALI-01 DCDALCI DALI-02 DCDALCI DALI-03 DCDALCI DALI-04 DCDALCI DALI-05 DCDALCI DALI-06 DCBM-DALI Line Controller DCBM-DALI Line Controller Ethernet Cabling to Other Levels DCLCD35 Control Panel or DCLCD70 Touch Panel Notes: • Ethernet network cabling must be completed to Ethernet standards. • The Ethernet switch in the distribution board is not required if a separate Cat5. cable is run from the main switch to each DCBM DALI line controller. CLIPCOM 21240 May 2010 2004 © Copyright Clipsal Australia Pty Ltd. The identified trademarks and copyrights are the property of Clipsal Australia Pty Ltd unless otherwise noted. www.dalicontrol.com Wiring Typical Switchboard Layout a.c. Supply N L +V B -V Notes: Height Width 93 78 93 78 Depth Height Width Depth 56 Part Number DCBM1-1608 92 216 63 36 DCBM2-1608 92 216 63 120 140 54 120 140 54 DCP24/30 93 78 56 DCBM2-0808 DCP24/60 93 78 36 DCBM2-1602 DCDALP200 90 17 58 DCDALP250 90 34 57 DCDALCI 100 50 30 CLIPCOM 21240 May 2010 2015 DCDALCI BMxxxx-DALI Line Controller Ethernet Gateway Dimensions (shown in mm) DCP12/60 DCDALCI A DCDALPxxxxx Part Number DCP12/30 DALI-B To Switches and Push Buttons, Occupancy and Light Sensors, Security and Access Control Panels, etc. RJ45 Ethernet DCPxx/xx Power Supply DALI-A • DCDALPxxxxx should be separated by spacers to allow air flow and avoid overheating. • DCPxx/xx power supplies can power multiple BM-DALI line controllers and sensors, according to the accumulated load. © Copyright Clipsal Australia Pty Ltd. The identified trademarks and copyrights are the property of Clipsal Australia Pty Ltd unless otherwise noted. www.dalicontrol.com Wiring DALI DCDALxxxxx Wiring Overview To CCT Breaker Starter Socket Socket or T-Piece L L N N DA DA DA DA 12VDC IN0 IN1 IN2 IN3 OUT0 OUT1 GND L N DCDALxxxxx (1 Address) DA DA DALI Control DCDAL Series DCDALIO-0402 Room Controller DCDALO-02 2-Channel Output Module Input Circuit using 12V Relay Input Circuit Output Circuit 12V d.c. 12V d.c. 12V d.c. R1 R2 Load (12V Relay Coil) R1 INx Relay (12V Coil) R2 INx OUTx C C GND Internal Circuit CLIPCOM 21240 May 2010 2006 GND External Components Internal Circuit External Components GND Internal Circuit © Copyright Clipsal Australia Pty Ltd. The identified trademarks and copyrights are the property of Clipsal Australia Pty Ltd unless otherwise noted. External Components www.dalicontrol.com